1、施工設計提交成果Deliverables of Construction Drawings燈光照明Lighting對于燈光照明專業(yè)施工圖設計深度標準及技術深度文件現(xiàn)規(guī)定如下:The design depth and technical scope of special lighting working drawing are specified as follows:一.各區(qū)域,各房間的照度計算書及燈具選型、燈位布置;I . Illumination calculation sheet and type selection and positioning of lights each in r
2、oom in all areas;二照明控制系統(tǒng)中所采用設備的說明書;II Instructions of equipment used in the lighting control system;三.燈具資料表(用EXCEL表格做出,格式如下,第一行內容為示范);IIL Data sheet of lighting (in EXCEL, with the format as follows; contents in the first row are filled in as an example);序 號 No.編號S/N設備位置 Equipme nt position品牌 Bran d
3、設備型號Equipme nt model光源Lightsources設備數(shù)量 Equipmen t quantity產地Origin圖片Picture1VASLEDI-Panel/RGB-PL-12030-A9顆whiteLED3000K10W14廣州 Guangzho u234567總it142四.對施工圖紙的要求如下:IV. Requirements for Construction Drawings用于設計方案階段的一套完整的圖紙至少應包括封面、圖紙目錄、工程設計說明及圖 例、設備材料清單、系統(tǒng)圖、平面圖。A complete set of drawings used in the de
4、sign stage shall at least include the cover, drawing content, engineering design instructions and graphic symbols, list of equipment and materials, system diagram, and plan view.用于施工階段的圖紙至少應包括封面、圖紙目錄、工程設計說明及圖例、設備材料清 單、系統(tǒng)圖、平面圖及設備的安裝大樣圖。A complete set of drawings used in the construction stage shall a
5、t least include the cover, drawing content, engineering design instructions and graphic symbols, list of equipment and materials, system diagram, plan view, and the detail drawing of equipment installation.照明專業(yè)圖紙范圍如下:Scope of drawings for lighting is as follows:必須包括封面、圖紙目錄、工程設計說明及圖例、設備材料清單、系統(tǒng)圖、平面圖、
6、機房設備布置圖、安裝大樣圖。安裝詳圖根據(jù)項目情況,應由設計師根據(jù)項目的可實現(xiàn)性 和各專業(yè)分項工程的配合決定繪圖深度,設計出滿足項目需求的可實施的拓展性安裝詳圖。It shall include the cover sheet, drawing content, engineering design instructions and graphic symbols, list of equipment and materials, system diagram, plan view, layout of equipment in equipment room, and detail drawin
7、g of equipment installation. Feasible and extendable detail drawing for equipment installation shall be designed according to the project situations by the designer who shall decide the depth of drawing according to the project feasibility and coordination between all subdivisional works of each dis
8、cipline to satisfy the project requirements.4.1 封面 Cover封面應包含項目名稱、圖紙性質(初步設計、施工圖、竣工圖等)、公司名稱、日期。The cover shall bear the project name, drawing property (preliminary design, construction drawing, as built drawing, etc.), company name, and date.4.2 圖紙目錄 Drawing content圖紙目錄應包含以下內容:項目名稱、項目編號、設計公司名稱、專業(yè)、圖紙名
9、稱、 圖紙編號、圖幅、出圖日期、制圖人及審核人等內容。The drawing content shall include the following: project name, project ID, name of design corporation, discipline, drawing name, drawing number, sheet, drawing finishing date, the person who draws, and the auditor.4.3 工程設計說明及圖例 Engineering design instructions and graphic s
10、ymbols設計總說明須包括但不限于:工程概況、設計依據(jù)、各子系統(tǒng)施工內容、施工要求和 注意事項、設計特殊要求和施工配合要點、設計范圍內智能化系統(tǒng)與相關專業(yè)的技術接口 要求、圖例符號等。The general design instructions shall include, without limitation to: Project profile, design basis, constmction contents of each sub system, construction requirements and notices, special design requirement
11、s and key points in construction cooperation, technical interface requirements for the intelligent system and relevant disciplines within the scope of design, graphic symbols, and so on.4.4 設備材料清單 List of equipment and materials在材料表中的圖形符號圖例應采用國標,其次是部標、行標。未予規(guī)定的自擬圖形圖 例,應在圖例中標出且加以說明。當使用國標圖形圖例,乂給予不同含義時也
12、應加以說明, 一套圖紙的圖例符號應前后一致。Graphic symbols in the list of materials shall adopt those in national standards, followed by ministerial standards and industry standards. Self made graphic drawings not specified shall be marked in the graphic symbols with explanations. Explanations shall also be given when g
13、raphic symbols in national standards are given different meanings. The graphic symbols used in one set of drawings shall be in consistence with each other.設備材料清單,按系統(tǒng)開列組成系統(tǒng)主要設備和材料,應標明設備名稱、規(guī)格型號、 主要技術指標、品牌(產地)、數(shù)量。非標設備、材料應備注說明技術要求。The list of equipment and materials shall list the major equipment and ma
14、terials constituting the system, with an indication of the equipment name, specification and model, key technical indicators, brand (origin), and quantity. Technical requirements for nonstandard equipment and materials shall be marked.各個平面圖、設備房圖應隨附圖例并標注數(shù)量。包括電腦、軟件、編程工具、機柜、 電源、變壓器等設備材料都必須在圖紙上或設備材料中體現(xiàn)出
15、來,并且注明型號、規(guī)格、數(shù)量總和。All plan views and equipment room drawings shall be attached with graphic symbols and quantity. Equipment and materials including computers, software, programming tools, cabinets, power supply and transformers shall be indicated in the drawings or list of equipment materials, with c
16、lear indication of the modeL specification and total quantity.4.5 系統(tǒng)圖System diagram451照明供配電系統(tǒng)圖:應注明系統(tǒng)結構、主要配置、終端分布、主干線纜、供電要求、文字說明等。 具體設計原則請參考民用建筑電氣設計規(guī)范JGJ 16-2008第3章,第4章。當有類似5D劇場有人員 參與演出涉及舞臺照明時,舞臺照明的供電與負荷計算應參照民用建筑電氣設計規(guī)范JGJ 16-2008 第9章9.6節(jié)的相關規(guī)定。Drawing of lighting power supply and distribution system:
17、With clear indication of the system structure, major configuration, terminal distribution, trunk cables, power supply requirements, explanatory notes, etc. For detailed principles for design, please refer to chapters 3 and 4 of JGJ 16-2008 Code for Electrical Design of Civil Buildings .When there ar
18、e personnel participating in the stage show in likely-to-be 5D theater with stage illumination involved, power supply and load calculation of stage illumination shall refer to the related regulations of Section 9.6, Chapter 9 of JGJ 16-2008 Code for Electrical Design of Civil Buildings.注意:Notes:1當采用
19、可控硅做調光設備時,其電源變壓器宜采用接線方式為/()的變壓器。When SCR components are used as dimmer device, the supply transformer shall be / Y0 transformer.2.為抑制高次諧波對照明控制裝置及其它系統(tǒng)設備的干擾,除應滿足民用建筑電氣設計規(guī)范JGJ 16-2008第22章第22.3節(jié)的規(guī)定外,還應注意:電聲,電視轉播設備的電源不直接在照明用電變壓器 上。To restrain the interference of ultraharmonics on illumination control dev
20、ices and other system equipments, except that the regulations of Section 22.3, Chapter 22 of JGJ 16-2008 Code for Electrical Design of Civil Buildings shall be met, shall take note of the following: the power supply of electroacoustic and television relay equipment shall not connect to the transform
21、ers for illumination.452配電箱系統(tǒng)圖:應標注配電箱編號、型號、進線回路編號:標注各開關(或熔斷器)型號、規(guī)格; 標注出線回路編號、導線型號規(guī)格;負荷量:對于單相應標明相別;并標明負荷名稱。具體設計原則請 參考民用建筑電氣設計規(guī)范JGJ 16-2008第7章,建筑照明設計標準GB 50034-2004第7章。System diagram of switch box: It shall indicate the switch box No., model, and lead-in loop No.; it shall also indicate the model and
22、specification of switches (or fuses), outgoing line loop No., and model and specification of leads, as well as the load capacity; the phase sequence shall be marked for single-phase wire; the load name shall also be marked. For details, please refer to chapter 7 of JGJ 16-2008 Code for Electrical De
23、sign of Civil Buildings and chapter 7 of GB 50034-2004 Standard for Lighting Design of Buildings.4.5.2.1 配電箱系統(tǒng)圖須考慮三相平衡,三相配電干線的各相負荷宜分配平衡,最大相負荷不宜超過三 相負荷平均值的115%,最小相負荷不宜小于三相負荷平均值的85%。In making the system diagram of switch box, equilibration of the three-phase system shall be considered; load on each wi
24、re of the three-phase distribution trunk shall be distributed in equilibration; the maximum phase load shall not exceed 115% of the mean loads of the three-phase system, and the minimum phase load shall not be smaller than 85% of the mean loads of the three-phase system.4.5.2.2 如有供給氣體放電燈的三相配電線路,其中性線
25、截面應滿足不平衡電流及諧波電流的要求,且 不應小于相線截面。If there is three-phase power distribution line for the gas discharge lamp, its neutral line section shall meet the requirements of unbalance current and harmonic current and shall not be smaller than the phase line section.4.5.2.3 明配電箱應保留備用回路,備用回路的數(shù)量不應低于配電箱回路數(shù)量的30%0The
26、 light distribution box shall have a backup loop, and the number of backup loops shall not be smaller than 30% of the number of switch box loop.452.4照明設備的接電方法,應采用專用接插件連接,接插件額定容量應有足夠余量。Power connection of lighting equipments shall adopt the dedicated connectors and the rated capacity shall be enough.
27、4.5.2.5由晶閘管調光裝置配出的舞臺照明線路宜采用單相配電。當采用三相配電時,宜每相分別配置中 性導體,當共用中性導體時,中性導體截而不宜小于相導體截面的2倍。For the stage lighting lines distributed by thyristor light-controlling device, single-phase distribution shall be adopted. When adopting three-phase distribution, it is appropriate to distribute neutral conductor resp
28、ectively in each phase; when neutral conductor is used in common, its cross section shall be not less than 2 times that of phase conductor.452.6照明設備應根據(jù)低壓配電系統(tǒng)的接地形式確定采用接地保護措施。Lighting equipments shall determine ground protection measures according to the earthing form of low-voltage distribution syste
29、m.453.照明控制系統(tǒng)圖:應標注控制箱編號、型號:標注控制回路編號、導線型號規(guī)格、通訊協(xié)議、接口 界而、控制系統(tǒng)若與其它設備有接口,須標明接口類型。Lighting control system diagram: It shall indicate the controlling box No. and model; control loop No., model and specification of leads, communication protocol, and interface; if the control system has an interface with othe
30、r equipment, mark the type of interface.4531控制系統(tǒng)采用專用接地裝置時,接地電阻值不應大于4Q。采用共用接地裝置時,接地電阻值不 應大于1。oWhen the control system adopts special earthing device, the resistance to earth shall not be greater than 4Q. Wlien a common earthing device is used, the resistance to eaith shall not be greater than IQ453.2
31、乙級及乙級以上電影院觀眾廳(主演區(qū),預演區(qū))的照明應能漸亮漸暗平滑調門或分檔調節(jié).Lighting in the audience hall of class B or above cinemas (performance area and rehearse area) shall be capable of changing from bright to dim state gradually and smoothly or can be adjusted by different grades.4.5.33入口、排隊區(qū)、上客區(qū)、下客區(qū)、主演區(qū)、預演區(qū)等直接為觀眾服務的地區(qū)的照明控制開關應
32、集中單獨控制。The lighting control switches in the areas directly serving the audiences, such as the entry, queue area, load on/off areas, performance area and rehearse area shall be intensively and independently controlled.4.53.4 當采用調光設備時,每一照明回路的可載容量,應與所選用的調光設備的回路輸出容量相適應, When using the light-controlling
33、devices, the load capacity for each lighting loop shall be compatible with the output capacity of the selected light-controlling device.4.53.5 類似5D劇場有人員參與演出的舞臺調光控制裝置的選擇和安裝應符合下列要求:The selection and installation of stage light-controlling devices withpersonnels participation in the stage show in the l
34、ikely-to-be 5D theatershall conform to the foilwing requirements:1 .舞臺照明調光控制器的選型:小型劇場,可選用帶預選裝置的控制器,中型及以上規(guī)模的劇場,宜選 用帶計算機的控制器。Model selection of stage illumination light-controller: for small-sized theater, the controller with pre-elected device could be selected: for the theater with middle size and a
35、bove, the controller with computer could be selected.2 .舞臺照明調光控制臺宜安裝在觀眾廳后部的燈控室內,并應符合下列規(guī)定:Stage illumination lighting console shall install in the lighting control room in the back of auaditorium and conform to the following reaulations:(1)調光柜和舞臺配電設備應設在靠近舞臺的單獨房間內;Dimmer cabinet and stage distribution
36、 equipment shall be set up within the single room close to the stage: (2)舞臺表演區(qū)應在燈光控制人員的視野范圍內;Stage acting area shall be in the field of view of light-controlling personnel;(3)燈控人員應能容易的觀察到觀眾席的情況:Lieht-controlling personnel shall be able to easily observe the auditorium;(4)應與舞臺布燈配光聯(lián)系方便:Shall be in con
37、venient contact with lamp collocation and light distribution of the stage.(5)調光設備與線路應安裝敷設方便。Light-controlling equipments and pipelines shall be conveniently installed and laid.4.A平面圖Plan view461總體要求General requirements(1)照明配電箱宜設置在靠近照明負荷中心便于操作維護的位置.The light distribution box shall be placed in the pl
38、ace which is near to the lighting load center and convenient for operation and maintenance.(2)其他具體設計標準參考我國電影行業(yè)標準電影院建筑設計規(guī)范JGJ58-2OO8中對于電氣及照明方 而的要求。Other detailed design criteria shall conform to the relevant requirements about electricity and lighting in China*s cinema industry standard JGJ58-2008 Co
39、de for Architectural Design of Cinema.4.6.2線槽設計Trunking design由強、弱電豎井或控制機房引向用電負荷的電氣線路,在回路眾多的情況下應采用線槽布線。The electric wiring drawn from vertical shaft for light-current and strong-current or control cabinet shall adopt trunking when there are numerous loops.462燈光專業(yè)線槽種類按走向通常分為:水平線槽、垂直線槽。燈光專業(yè)線槽種類按系統(tǒng)通常分為
40、: 弱電控制信號線綜合線槽、強電電纜線槽。強、弱電線槽應分別設置,不允許共用,具體設計原則請參 考民用建筑電氣設計規(guī)范JGJ 16-2008第8章0According to the trend, special lighting trunking can usually be divided into: horizontal tnjnking and vertical trunking. According to the system, special lighting trunking can usually be divided into: integrated trunking for
41、light-current control signal lines and trunking for strong-current cables. Trunking for strong-current and light-current shall be set respectively and shall not be shared. For detailed principles for design, please refer to chapter 8 of JGJ 16-2008 Code for Electrical Design of Civil Buildings.4.6.2
42、.2燈光專業(yè)線槽繪制時,原則上應按線槽實際寬度按圖紙比例繪制,線槽截面應采用空心閉合圖 形。In principle, the special lighting tnjnking shall be drawn according to the actual width of trunking and the drawing, and the trunking section shall be a hollow closed figure.4.623在進行對線槽的標注時,應能清楚地分辨出線槽的型號、規(guī)格、敷設方式。When marking the trunking, the model, spe
43、cification and laying method shall be clearly distinguished.4.6.3管線圖Piping plan具體設計原則請參考民用建筑電氣設計規(guī)范JGJ 16-2008第8章。建筑照明設計標準GB 50034-2004 第7章。For details, please refer to chapter 8 of JGJ 16-2008 Code for Electrical Design of Civil Buildings and chapter 7 of GB 50034-2004 Standard for Lighting Design o
44、f Buildings. 以下所述在設計時應特別注意:Special attention shall be paid to the following durin。design:1.1.1 標明或注明設備的類別、編號、平面位置、安裝高度、安裝方式,管線、線槽走向、管線規(guī)格, 敷設方式、引上引下、圖例、數(shù)量、文字說明等。Indicate or note equipment type, S/N, plan position, mounting height, mounting method, pipeline and trunking trend, pipeline specification,
45、laying method, leading up/down, graphic symbols, quantity, explanatory note, etc.1.1.2 每一照明單相分支回路的電流不宜超過16A.所接光源數(shù)不宜超過25個:連接建筑組合燈具時, 回路電流不宜超過25A,光源數(shù)不宜超過60個:連接高強度氣體放電燈的單相分支回路的電流不應超 過 30A。Current of each single-phase subcircuit for lighting shall not exceed 16A, and there shall be less than 25 ilkimina
46、nts; when connecting the combined lights, the loop current shall not exceed 25A, and there shall be less than 60 ilkiminants; current of the single-phase subcircuit connecting high capacity gas discharge lamp shall not exceed 30A.1.1.3 3照明配電干線及分支線,應采用銅芯絕緣電線或電纜,分支線截面不應小于L5mm2。Trunk lines and branch l
47、ines for light distribution shall be copper core insulated conductor or cable; section of branch line shall not be smaller than 1.5mm2.1.1.4 觀眾廳及放映機房等處墻面及吊頂內的照明線路應采用阻燃型銅芯絕緣導線或銅芯絕緣電纜穿 金屬管或金屬線槽敷設。Illuminating lines inside the walls and suspended ceiling in audience halls and projector chambers shall a
48、dopt flame retardant copper core insulated conductor or copper core insulated cable wrapped with metal tube or metal raceway.1.1.5 插座不應和照明設備接在同一回路,Sockets shall not be connected with lighting equipment in the same loop.1.1.6 原則上采用不同發(fā)光原理的光源的燈具不要接在同一回路上,特別是以氣體放電燈為光源的燈 具不要和其他類型光源的燈具接在同一回路上。In principle
49、, lighting fixtures using different ilkiminants shall not be connected in the same loop; in particular, lighting fixtures with gas discharge lamp as the illuminant shall not be connected with the lighting fixtures using other ilkiminants in the same loop.1.1.7 照明電氣管線布線平面圖上應注明其管線來自配電箱的編號和回路編號以便于審查是否與
50、配電 箱系統(tǒng)圖的回路編號相對應,且是否回路連接的負荷總量與配電箱系統(tǒng)圖上標明的相符。The pipeline wiring diagram of lightings shall indicate the No. of switch box from which the pipeline is drawn and the No. of loop, so as to check whether it coincides with the No. of loop of the switch box system diagram, and whether the total load connecte
51、d with the loop coincides with that on the switch box system diagram.1.1.8 圖紙中管線的走向應考慮現(xiàn)場施工條件及后期檢修維護的便利,并盡可能與實際的排管布線方 向一致。Trend of pipelines in the drawing shall consider the site operation conditions and provide convenience for future repair and maintenance, and shall be the same as the actual pipel
52、ine trend as much as possible.1.1.9 抑制高次諧波對照明控制裝置及其它系統(tǒng)設備的干擾,除應滿足民用建筑電氣設計規(guī)范JGJ 16-2008第22章第22.3日的規(guī)定外,還應滿足以下要求:需要調光的回路應選用金屬導管、槽敷設, 并不宜于電聲等電信線路平行敷設。當調光回路與電信線路平行敷設時,其間距應大于1米:當垂直交 叉時,其間距應大于0.5米。To restrain the interference of ultraharmonics on illumination control devices and other system equipments, exc
53、ept that the regulations of Section 22.3, Chapter 22 of JGJ 16-2008 Code for Electrical Design of Civil Buildings shall be met. shall conform to the following requirements: the loop that needs light control shall select metal conduit and tninking for lay-up, and parallel lay-up of electroacoustics e
54、tc. telecommunication lines is not suitable. When light-controlling loop are in parallel lay-up with telecommunication lines, the distance shall be more than Im; when in squre crossing, the distance shall be more than 0.5m.464機房、豎井布置平面圖Plane arrangement drawing of equipment room and vertical shaft照明
55、設備機房和豎井布置平面中的電氣設備、管線布置應遵循以下原則:The electric installation and pipeline layout in the plane arrangement drawing of lighting equipment room and vertical shaft shall conform to the following principles:(1)機房布置圖中應包括配電柜/控制箱平面位置布局、局部立而圖,注明管線、線槽走向,寫出文字 說明等,The equipment room arrangement drawing shall include
56、 the plane layout and partial elevation of the power distributing cabinet and controlling box, giving clear indication of the trend of pipelines and trunking, explanatory notes, and so on.平面圖上的設備位置、數(shù)量、編號,纜線規(guī)格、管線與線槽走向應與立面圖上的設備位置、數(shù)量、 編號,纜線規(guī)格、管線與線槽走向相對應。The equipment position, quantity, No., and cable
57、specification, pipeline and trunking trend on the plan drawing shall coincide with those on the elevation drawing.(3)機房內的控制箱、柜等設備應注明尺寸,間距、并標明設備型號。The controlling box and cabinet inside the equipment room shall be marked with the dimension, spacing and equipment type.(4)機房布置圖應注明機房空間內各設備安裝位置、相互關系及安裝工藝
58、要求。The equipment room airangement drawing shall give clear indication of the installation position, correlations between equipment, and technical requirements of installation of the equipment inside the equipment room.(5)控制信號的強、弱電井布置圖應具體反映強、弱電井內所有線槽、管路、設備箱等的位置、尺寸The arrangement drawing of strong and weak electricity well of control signals shall specifically reflect the position and dimension
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網頁內容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
- 4. 未經權益所有人同意不得將文件中的內容挪作商業(yè)或盈利用途。
- 5. 人人文庫網僅提供信息存儲空間,僅對用戶上傳內容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內容本身不做任何修改或編輯,并不能對任何下載內容負責。
- 6. 下載文件中如有侵權或不適當內容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 代寫課題申報書多少錢
- 成囊材料市場分析及競爭策略分析報告
- 企業(yè)生產線用工合同范本
- 中國傳統(tǒng)文化學習心得體會
- 廠家求購鋼材合同范本
- 臨床護理習題(附答案)
- 機械制造基礎模擬試題含答案
- 代理經營承包協(xié)議合同范本
- 箱包維修合同范本
- 流體力學復習題(含答案)
- 2024年遼寧省中考物理試題
- 2024年湖南電氣職業(yè)技術學院單招職業(yè)適應性測試題庫含答案
- CJJ 82-2012 園林綠化工程施工及驗收規(guī)范
- 數(shù)據(jù)庫原理及應用(第3版)
- 預防流感健康知識講座總結
- 國際標準《風險管理指南》(ISO31000)的中文版
- 幼兒園中班語言《猜燈謎》
- 煙花爆竹經營
- 射頻同軸電纜簡介
- 2023-2024全球及中國企業(yè)組織活力報告(中文版)
- 現(xiàn)代自來水廠自動化控制系統(tǒng)
評論
0/150
提交評論