Transducer Specification傳感器規(guī)范_第1頁
Transducer Specification傳感器規(guī)范_第2頁
Transducer Specification傳感器規(guī)范_第3頁
全文預覽已結(jié)束

下載本文檔

版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進行舉報或認領

文檔簡介

1、.February 19, 1998Sales AdministratorDear Sir,Here is a casual specification for a transducer that my client company wishes to obtain. Though we only need a few of these devices for evaluation at this time, the end application is for a product with an expected production rate of ten to fifty units p

2、er month . possibly more.To make a purchase order easy on all of us, I have modeled the specification around a standard product:Model CF3579In a recent telephone conversation . and after some thought . your very helpful associate decided that the transducer could be sold to us for the price of $250

3、each in “one at a time” quantities.His reasoning was that a) since we want a simplified version of a standard product . it should be less expensive than normal but . b) since it is a little different than usual is should cost more . therefore . in a wonderful example of the balance of nature . the p

4、rice should be the same as for a standard unit.If this is OK with you, I would like a quotation for quantities of 1, 5 and 50 units. I would also like an estimated delivery schedule for these devices.I am looking forward to being your customer and appreciate your good effort on our behalf.Sincerely

5、Yours,- CNCraig E. NelsonEngineerNotes:1.Center frequency of the transducer is 2.25 MHz + - 5 % .2.The transducer housing should not contain a tuning or impedance matching network.3.The outer casing for the transducer should preferably be made of some form of bondable plastic but 303 stainless steel

6、 is OK. Knurling is OK . but not required. There should be no hole in the side of the case.4.The piezoelectric element front electrode should preferably be electrically insulated from the front contact surface of the transducer. If isolation is not possible, dont worry about it.5.Electrical connecti

7、on should preferably be made by means of an RG-174 or smaller coaxial cable (shield goes to “front” side of element) that exits the top end of the transducer housing somewhat off toward the edge and at an angle of about 45 degrees. It is OK if the connection is a simple (red-black . black is “front”

8、 side) twisted pair and exits straight out from the center of the back of the housing. The leads should be about 4 inches long.6.Since maximum sensitivity rather than axial resolution is the requirement in this application, the piezoelectric element should be air backed. A “foam” backing material is OK. Straight epoxy or a loaded epoxy backing is not OK.7.The piezoelectric element contained within the housing may be as small as .375 inch diameter but . no smal

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負責。
  • 6. 下載文件中如有侵權(quán)或不適當內(nèi)容,請與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

評論

0/150

提交評論