




版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進行舉報或認(rèn)領(lǐng)
文檔簡介
Non-segregatedbusduct第21頁共21頁InstructionforinstallationandtestNon-segregatedbusduct1.Relateddocumentationsandstandards1.1.TheChinesestandard(GBJ149-90):Codeforconstructionandacceptanceofthebus1.2.TheChinesestandard(GB50150-91):Standardforhand-overtestofelectricequipment1.3.TheChinesestandard(DL408-91):Operationcodeforpowerplantsafety1.4.TheChinesestandard(DL560-95):Operationcodeforelectricsafetyinhighvoltagelaboratory1.5.TheChinesestandard(DL/T5043-95):Designstandardforelectricallaboratoryofthermalpowerplant1.6.TheChinesestandard(DL/T5161.4-2002):Specificationforconstructionqualitycheckoutandevaluationofelectricequipmentinstallation2.Receiptandstorage2.1.Examinethestateofthedevicesandthematerialsreceivedtocheckthatitcorrespondswithwhatwasordered.2.2.Checkallpackagesforexternalsignsofdamage.2.3.Pleasecheckconditionandqualityofthedevicesandthematerials,andcomparethemwiththepackinglist.2.4.Ifonunpacking,whichmustbecarriedoutcarefully,anydamageorirregularityisnoted,notifythiswithindefiniteperiodofreceiptofthegoods,notificationmustindicatetheshippingnotenumber.2.5.Ifthedevicesistobestoredforevenshortperiodsbeforebeingputintoservice,afterreceiptitisadvisabletoputitbackintoitsrelativecontainerandcoveritwithawaterprooftarpaulin.Useadryanddust-freeambientforstoragewithoutanyaggressivechemicalagents.Placethedeviceandanyfixedpartonahorizontalsurfacenotindirectcontactwiththefloor,butonasuitablesupport.2.6.Selectalocationforthedeviceinaclean,dry,vibration-freeareawithmoderatetemperature.2.7.Withregardtolifting,followtheseinstructions:thedevicesmustbeplacedonasturdysurfaceandpreferablyliftedusinganappropriateliftingforktruck.Theuseofropesis,however,permitted:inthiscasetheliftingropesmustbehookedfirmly.3.Installation3.1.Generalrequirement3.1.1.Surfaceofthebusesmightbeneatandsmooth,withoutcrack,twistinganddeformation.Qualitystandardsofthebusmaterialsareasshownin3.1.1.Table3.1.1.:ExaminationofthebusmaterialsNameTypeMinimumtensilestrength(N/mm2)Minimumextensibility(%)Maximumresistivityat20℃(Ωmm2/m)CopperbusTMY25560.01777AluminumbusLMY11530.0290AluminumalloybusLF21Y1370.03733.1.2.Don’tblowholesonthemetalstructuresbywelding.3.1.3.Carryoutanti-corrosiontreatmentformetalstructuresandbuses.Anti-corrosionpaintmightbeuniformandsolid,withoutpeelsandcorrugation.Outdoormetalstructuresmightbehotzincplated.3.1.4.Framesofthesupportinsulators,flangesofthebushingsprotectionmeshesandcoversmustbegroundedaccordingtothecodes.Theearthedwiresmightbeneatanduniform.3.1.5.Lappingconnectionbetweenbuses,busandbranch,busandterminalofelectricequipmentshouldconformtofollowrequirement:.Copperandcopper:musttinplated..Aluminumandaluminum:canconnectdirectly..Steelandsteel:musttinorzincplated..Copperandaluminum:coppershouldbetinplatedandwithtransitiveplatesbetweencopperandaluminumwhenoutdoororairrelativehumidityisnear100%..Steelandcopperoraluminum:lappingsurfaceofsteelmustbetinplated..Lappingsurfacesoftheclosedbus-barswhicharefixedwithboltsshouldbesilverplated.3.1.6.Safetyintervalsoftheindoordistributionequipmentsduringinstallationofthebusesareasshownintable3.1.6.Table3.1.6.:Safetyintervals(mm)oftheindoordistributionequipmentsRatedvoltage(kV)0.4156.62033132and220Betweenelectrifiedpartsandgroundedpartsorfences751251803001800Betweendifferentphasesofelectrifiedparts751251803002000Betweentwosidesoffractureinthecircuitbreakersortheisolatingswitches751251803002000Betweenelectrifiedpartsandmeshfences82587593010502550Betweencrosselectrifiedpartswithoutfenceswhicharen’trepairedatsametime82587593010502550Betweennakedbuseswithoutfencesandgroundorfloors23752425248026004100Betweenparallelnakedbuseswithoutfenceswhicharen’trepairedatsametime18751925198021003600Betweenoutletbushingsandoutdoorroads400040004000400055003.1.7.Safetyintervalsoftheoutdoordistributionequipmentsduringinstallationofthebusesareasshownintable3.1.7.Table3.1.7.:Safetyintervals(mm)oftheoutdoordistributionequipmentsRatedvoltage(kV)6.62033132and220400Betweenelectrifiedpartsandgroundedpartsorfences20030040018002800Betweendifferentphasesofelectrifiedparts20030040020004300Betweentwosidesoffractureinthecircuitbreakersortheisolatingswitches20030040020004300Betweenelectrifiedpartswithoutfencesandcasingsoftransportingequipments9501050115025504550Betweencrosselectrifiedpartswithoutfenceswhicharen’trepairedatsametime9501050115025504550Betweenelectrifiedpartsandmeshfences9501050115025504550Betweenelectrifiedpartsduringliveworkingandgroundedparts9501050115025504550Betweennakedbuseswithoutfencesandground27002800290043007500Betweennakedbuseswithoutfencesandtopsofthearchitecturesorthestructures27002800290043007500Betweenparallelnakedbuseswithoutfenceswhicharen’trepairedatsametime22002300240038005800Betweennakedbuseswithoutfencesandedgesofthearchitecturesorthestructures220023002400380058003.2.Qualitystandardsinstallingthesupportracksandthehangracksofthebusesareasshownintable3.2.Table3.2.:InstallationofsupportandhangracksofthebusesExaminationitemsPropertyQualitystandardsMethodsandtoolsofexaminationExaminationoftheshapesteelShapesteelspecificationInaccordancewiththedesignsCheckdependonthedrawingsPermittederrorsofstraightnessofawholeshapesteel≤5mmCheckbyaruleAppearanceoftheboltholesandsurfacesSmooth,withoutdeformationInspectionInstallationofthesupportracksandthehangracksLevelerrors≤5mmCheckbyalevelgaugeHorizontalerrorsCheckbyaruleVerticalerrorsalonginstallationdirectionDiagonalerrorsofthesupportracksFixtureofthesupportracksandthehangracksMainSolidandreliablePullPaintEliminaterustMainClean,withoutrustInspectionBrushanti-corrosionpaintUniformandperfectEarthMainSolidandconductivePullandconductanceexamination3.3.Qualitystandardsinstallingprotectivefencesareasshownintable3.3.Table3.3.:InstallationoftheprotectivefencesExaminationitemsPropertyQualitystandardsMethodsandtoolsofexaminationExaminationoftheshapesteelShapesteelspecificationInaccordancewiththedesignsCheckdependonthedrawingsPermittederrorsofstraightnessofawholeshapesteel≤5mmCheckbyaruleAppearanceoftheboltholesandsurfacesSmooth,withoutdeformationInspectionManufactureoftheframesWeldoftheframesMainSolid,inaccordancewiththecodesofweldtechnologyPullandinspectErrorsoftheoutlinedimensions≤5mmCheckbyaruleDiagonalerrorsUnevennessoftheframesInstallationofthefencesExaminationofthemeshplatesEvenCheckbyaruleExaminationofthemesheyesFirmanduniformPullGapbetweentheframesandthemeshplates≤5mmCheckbyaruleVerticalerrorsofthefencesPaintEliminaterustMainClean,withoutrustInspectionBrushanti-corrosionpaintUniformandperfectEarthEarthofthefencesMainReliableearthwiththesoftconductorsPullandconductanceexaminationEarthoftheframesFirmandconductive3.4.Installationoftheinsulators3.4.1.Porcelainsandflangesoftheinsulatorsshallbeperfectandwithoutcrack,fillerscompleteatthejoints.3.4.2.Topsandcentrallinesofthepostinsulatorsshallbeneat.Itisinhibitedthatburythebottomcasesandtheflangesintoconcreteorplasterlayer.3.4.3.Padsomerubberorasbestossheetwashers,whichthicknessesarethickerthan1.5mm,betweencontactsurfacesofthepostinsulators,whichwithoutbottomcasesandcaps,andmetalfixturesforbuffer.3.4.4.Caninstallthesuspensioninsulatortrainsvertically.Stressesontheparallelsuspensioninsulatortrainsshallbeuniform.Thebolts,pins,lockspringsandetc.whichlinkupthemetalfittingsshouldbecomplete,andthosedirectionsshouldbeuniform.Theball-eyes,socket-cleviseyesandlockpinsoftheinsulatortrainsshouldbematcheachother.Installprotectivefittingsfirmlyandcorrectlyforexamplegradingrings,screenringsandetc.3.4.5.Qualitystandardsinstallingthesuspensioninsulatortrainsareasshownintable3.4.5.Table3.4.5.:InstallationofthesuspensioninsulatortrainsExaminationitemsPropertyQualitystandardsMethodsandtoolsofexaminationVisualexaminationTypeandspecificationInaccordancewiththedesignsCheckdependonthedrawingsAppearanceoftheporcelainMainPerfect,smoothandclean,withoutcrackInspectionExaminationofthejointsbetweenporcelainandironMainFirmMetalfittingsandaccessoriesCompleteandperfectExaminationofthespringpinsEnoughspringPullExaminationofthegradingringsandscreenringsComplete,withoutdeformationInspectionInstallationoftheinsulatortrainsTestbeforeassemblyoftheinsulatorsMainQualifiedChecktestreportsDirectionofthebolts,pins,springpinsandetc.UniformInspectionMatchbetweentheball-eyes,socket-cleviseyesandlockpinsFlexible,withoutblockPullExaminationofanti-loosedmeasuresformetalfittingsMainTightanti-loosed,openforelockInspectionPermittedslopeanglesofthesuspensioninsulatortrains≤5oInspectionStressesonparallelinsulatortrainsMainUniformIntegerexaminationoftheinsulatortrainsbeforeliftCleanandcorrect3.4.6.Qualitystandardsinstallingthepostinsulatorsareasshownintable3.4.6.Table3.4.6.:InstallationofthepostinsulatorsExaminationitemsPropertyQualitystandardsMethodsandtoolsofexaminationVisualexaminationAppearanceoftheporcelainMainPerfect,smoothandclean,withoutcrackInspectionExaminationofthejointsbetweenporcelainandironFirm,withoutseamsInstallationoftheinsulatorsHorizontalerrorsoftheinsulatorbottomcases≤5mmCheckbyaruleErrorsofcentrallinesofthepostinsulatorsinstraightsegmentsMain≤2mmCheckbyaruleVerticalerrorsofthepostinsulatorsinlapmannerThicknessofthewashersbetweencontactsurfacesofmetalsandporcelaininsulatorsMain≥1.5mmFixtureoftheinsulatorsMainCompletebolts,tightfixtureCheckbyawrenchEarthLineoftheearthedwiresUniformdirectionInspectionConnectionwiththeearthednetworkMainSolidandconductivePullandconductanceexamination3.5.Installationofthewallbushings3.5.1.Porcelainsandflangesofthewallbushingsshallbeperfectandwithoutcrack,fillerscompleteatthejoints.3.5.2.Topsandcentrallinesofthewallbushingsshallbeneat.Itisinhibitedthatburythebottomcasesandtheflangesintoconcreteorplasterlayer.3.5.3.Diametersofholesforinstallthewallbushingscanbemore5mmandabovethanthatofembedparts.Thicknessesoftheconcreteplatescan’texceed50mm.3.5.4.Don’tmakeclosedmagneticcircuitsaroundthewallbushingswhichratedcurrentsare1500Aandabovewhenfixthemonsteelplatesdirectly.3.5.5.Theflangescanupwheninstallthewallbushingsvertically,anditoutsideifhorizontally.3.5.6.Usenon-magneticmaterialsformetalclampersatendsofthewallbushingswhichratedcurrentsare600Aandabove.Connectfirmlythemetalclamperstothebuses.Thicknessesofthemetalclamperscanmorethan3mm.3.5.7.Noleakageontheconservatorsandoilpipesforsamplewheninstalltheoil-filledbushingshorizontally.Installthevalvesforoilinjectionandsampleatinspectionside.Oilinthebushingsmustbequalified.3.5.8.Thebushingsandsparevoltagesampleterminalsshouldbeearthedwiththeearthedterminals.3.5.9.Qualitystandardsinstallingthewallbushingsareasshownintable3.5.9.Table3.5.9.:InstallationofthewallbushingsExaminationitemsPropertyQualitystandardsMethodsandtoolsofexaminationVisualexaminationAppearanceoftheporcelainMainPerfect,smoothandclean,withoutcrackInspectionExaminationofjointsbetweenporcelainandironMainFirmjoint,withoutseamInstallationofthebushingsMatchbetweenpreparedholediametersandembedpartsofthebushings>5mmCheckbyaruleThicknessesoftheconcreteplatesforinstallation≤50mmSteelplatesforfixtureof1500AandabovebushingsWithoutclosedmagneticcircuitsInspectionLocationoftheflangesInstallverticallyUpInstallhorizontallyOutside600AandabovebushingsMetalclampplatesatendMaterialsoftheclampplatesMainNon-magneticmaterialsInspectionThicknesses≥3mmCheckbyaruleEquipotentialconnectionbetweenthemetalclampplatesandthebusesMainFirmandreliableInspectionOil-filledbushingsExaminationofsealMainWithoutleakageInspectionIndicationofoillevelsMainNormalBoltsforconnectionMainCompleteandtightCheckbyawrenchEarthterminalsandsparevoltagesampleterminalsMainEarthreliablyPullandconductanceexamination3.6.Installationofthehardbuses3.6.1.Thebusissuppliedbythemanufacturer,formingacompletesetwiththeswitchcabinetorotherequipments.Thesurfaceofbusesshouldbecleanandsmooth.Theremustnotbeanycrack,foldline,thingsmingledwith,orthephenomenonofdeformationandsprainbendingonthebussurface.3.6.2.Thebusassemblingandconnectingshouldproceedaccordingtotheseriesnumberofbusassemblysuppliedbythemanufacturer.Thephaseorderoferectedbusshouldbeidenticalwiththatofthesystem.Thephasesymbolwrappingshouldbeobviousandingoodcondition.3.6.3.Theerectionofjoiningsurfacesintheboltconnectionbetweenbusandbus,orbetweenbusandtheterminalofelectricaldeviceshouldmeetthefollowingrequirements..Thecontactsurfacesofbusesshouldbekeptcleanandappliedacoatofelectricpowercomplexgreaseafterbeingprocessed..Whenthebusishorizontallyplaced,therunthroughboltsshouldrunupwardfromtheunderneathofthebus.Intheothercircumstances,thenutsshouldbeplacedatthemaintenanceside.Thelengthoftheboltshouldbelongenoughsoasforthebolttoemergeoutofnut2-3threads..Atthetwooutersidesofthebusesconnectedbytherunthroughbolt,platewashersshouldbeplaced.Thenetclearancebetweenadjacentboltwashersmustbeover3mm,andatthenutsidespringwasherorjamnutmustbeused..Theboltsshouldreceiveevenforce.Extrastressshouldnotbeappliedtotheconnectionterminalofelectricaldevice..Thecontactsurfacesofbusesshouldconnecttightly,usemomentwrenchtofastentheconnectingbolts,thevalueofthefasteningmomentshouldbeinaccordancewiththeregulationintable.Table.:Fasteningmomentvalueforsteel-madeboltsBoltspecification(mm)Momentvalue(N·m)M88.8~10.8M1017.7~22.6M1231.4~39.2M1451.0~60.8M1678.5~98.1M1898.0~127.4M20156.9~196.2M24274.6~3.Fasteningbusesonthepropinsulatorshouldmeetthefollowingrequirements..Thefixationoffasteningmetallicarticlesofbuswiththepropinsulatormustbesmoothandfirm.Donotletthebus,proppedbytheinsulator,receiveextrastress..Thefasteningmetallicarticlesorothersupportingmetallicarticlesofalternatecurrentbusmustnotformaclosedmagneticcircuit..Whenthebusishorizontallyplaced,theupperpressingboardofthebussupportingsplintshouldkeepaclearanceof1-1.5mm,withthebus,whilethebusisverticallyplaced,theupperpressingboardshouldkeepaclearanceof1.5-2mmwiththebus..Thedeadpointoffasteningbusonthepropinsulator,shouldbesetoneoneachsection,andbelocatedatthemiddlepointoftheentirelengthofthebussectionoratthemiddlepointoftwobusexpansionjoint..Thebusfasteningdevicesshouldbenoedgesandcornersorbur.3.6.5.Forthemultiplepiecerectanglebus,aclearanceofnotlessthanthethicknessofthebusshouldbekeptbetweenthem.Thespacebetweentheedgesoftheadjacentspacermustbemorethan5mm.3.6.6.Theleastsafetydistanceoferectedbustothegroundmustbenolessthan125mm.3.6.7.Afterthebushasbeenerected,thebusroomshouldbecleanedup.Usea2500Vmeg-ohm-metertochecktheinsulationresistancebetweeneachphaseofbusandtheinsulationresistanceofbustotheground.Generally,thevalueshouldnotbelessthan1MΩ/kV.Inthemeantime,erectioncheckrecordshouldbemade.3.6.8.Smallbuserection.Beforeerection,thesmallbusshouldbeleveledandstraightened,andsheathedwithplastictube;atbothsideofthesmallbusthereshouldbeatagmarkedwithitscodeorname.Thewritingmustbeclearandnoteasytodropoff..Theelectricalclearancebetweentheexposedcarryingcurrentpartsofthesmallbusatthetopofthecabinetthatareoutofphaseorofpoleorbetweentheexposedcarryingcurrentpartandthenon-insulatedmetallicobject,shouldnotbelessthan12mm;theelectricitycrawlingdistanceofthemshouldnotbelessthan20mm.3.6.9.Weldofthehardbuses.Argon-arcweldaluminumoraluminumalloybuses..Withoutoxidationfilms,water,greaseandimpurityonsurfacesofthebusesandtheweldingrods.Withoutfragmentandspewongroove..Alignthehardbusesstraightlyandevenlybeforeweld.Benddegreeshouldbelessthan0.2%,anddeviationofcentrallinesthan0.5mm..Reinforceheightsatthebuttweldseamsare2~4mm,thatatangleweldseamsare4mm.Thelengthsoftheweldseamsshouldbemorethan2timeswidthsofthebuseswhenlapweld..Sizesoftheweldingcratersareasshownintableandthegapsbetweenpipebusesandlinerpipesshouldbelessthan0.5mmwhenbuttweldaluminumoraluminumalloyshardbuses.Table.:CratersizesofbuttweldingBuscategoriesBusthickness(mm)Gaps(mm)Thicknessofobtuseedges(mm)Grooveangles(o)Rectangularbuses<5<251~21.565~756.3~12.52~41.5~265~75Pipebuses3~6.31.5~2160~656.3~102~31.560~7.Undercutdepthsmustn’texceed10%ofthebusthicknessandtotalundercutlengthmustn’texceed20%oftotallengthsoftheweldseams.3.6.10.Qualitystandardsinstallingpipebusesareasshownintable3.6.10.Table3.6.10.:InstallationofthepipebusesExaminationitemsPropertyQualitystandardsMethodsandtoolsofexaminationAluminumalloypipesandfittingsVisualexaminationofthealuminumalloypipesSmooth,withoutcrackInspectionAluminumalloyhatchesNeat,perpendiculartotheaxesCheckbyaruleFlexureofthealuminumalloypipesInaccordancewiththecodesCheckdependonthecodesExaminationofthemetalfittingsSmooth,withoutdamageandcrackInspectionWeldingofthepipebusesWeldingmannerMainArgon-arcweldingInspectionSizesoftheweldingcratersMainInaccordancewiththecodesCheckdependonthecodesTreatmentofthegroovesTreatsurfacesin50mmrangesattwosidesofthegroovesClean,withoutoxidationfilmsInspectionTreatedsurfacesofthegroovesMainWithoutfragmentandspewAlignmentofthehatchesBenddeviation≤0.2%CheckbyaruleDeviationofcentrallines≤0.5mmLinerpipesLocationoflongitudinalaxesMainAtcenterofthehatchesCheckbyaruleGapsbetweenthelinerpipesandthepipebuses≤0.5mmExaminationoftheweldseamsHeightofweldseams2mm~4mmCheckbyaruleAppearanceofweldseamsMainInaccordancewiththecodesInspectionInstallationofthepipebusesConnectionofthemetalfittingsMainWithoutclosedmagneticcircuitsInspectionFixtureofthemetalfittingsNeatandsolidInspectionIntervalsbetweentheweldseamsandthesupporters≥50mmCheckbyaruleGapsbetweenthebusesandbearingbracketsoftheslidetypesupporters1mm~2mmAppearanceoftheexpansionjointsMainWithoutcrack,breakandwrinkleInspectionAnti-coronadevicesatendsofthebusesSmoothsurfaces,withoutfragmentandspewInspectionPipeaxesofthethreephasebusesParalleleachotherInspectionExaminationofthegradingringsandscreencoversMainCompleteandsolid,withoutdeformationIntegerexaminationIntervalsbetweenelectrifiedconductorsandotherbodiesInaccordancewiththecodesCheckdependonthecodesRemarksofphasecoloronthebusesCompleteandcorrectInspection3.7.Installationofthenon-segregatedbusducts3.7.1.Thesequenceofinstallingnon-segregatedbus-ducts:Unpackingandcheckingofthedevices→Measurecentrallineandelevationofthefoundations,drawlines→Installsupportconstructionofthecasings→Positiontheoutgoingterminalcases→Positionthemainbus-ducts→Regulateandfixthemainbus-ducts→Installthewallbearingstructure→Positionthejointsofthebus-barsandcasings→Hardconnectionforbus-ducts→Softconnectionforbus-ducts→Groundingofthecasingsandthesupports→Clearanceinsideandsealairtight→Testcoordinately.3.7.2.Handling,unpacking,checkingofthenon-segregatedbus-ducts..Checkcarefullythebus-ductsanditsaccessoriesinboxesaccordingtotheoverallassemblydetail,thepartialassemblydetails,theshippingorderandthequalitycertificateofthenon-segregatedbus-ducts..Theboxesofdevicesshallbehangedatspecifiedpoints.Usesoftropesorsteelcableswithrubbersheath.Itisprohibitedtoshockandpullonground..Checkquantityofthedevicesanditsaccessories.Handlethemintimeiftheydamagedduetoshipment,andetc.3.7.3.Measureandrevisecentrallineandelevationofthefoundations.Checkfollowingdimension,accordingtothedesigndrawings,aligningtheterminalsofthetransformerandtheholesonwalloftheturbinehouse,fractionalerrorshallnotexceed±3mm/m,overallerrorshallnotexceed±5mm,orelserevising..Measurelongitudinalandtransversecentrallinesofthetransformers..Measurelongitudinalandtransversecentrallinesoftheswitchgears..ChecklocationanddimensionoftheholesonwalloftheturbinehousecolumnA..Maketheblacklinesasthecentrallinesofthenon-segregatedbus-ductsonindoorplatformandoutdoorsteelstructure.3.7.4.Installthesupportstructureofthecasing..Fixthesupportsbyweldingfirmly..Checktheelevationofthetopsofthebus-ductsupportsaccordingtodesignsanddrawingsfromthemanufactory..Installsteelstructuresofthenon-segregatedbus-ducts..Installthejointforverticalsectionandthesuspendingrodofthecasingsaccordingtodesigndrawings.3.7.5.Positionthebus-ductsanddevices..Assemblethesealequipmentsinsidethebus-ductsandcoatfluidsealantatthejointpriortoremovethebus-ductstotheinstallationsite..Checkthephasesequence,thenumbersandtherelativepositionsofallsectionsofbus-ductsaccordingtothedrawingsfromthemanufactory..Takethefalse-workoutsidetheturbinehousecolumnA.Thefalse-workshallbeprotruded1mfromthebus-ductattwosides..Installtheturretsonlowvoltagesideoftheunitorstationtransformer.Takethefalse-workoutsidetheturbinehousecolumnA,anditshallbeprotruded1mfromthebus-ductontwosides,itselevationisthesameasthesteelstructuresofbus-ducts..Overallregulationshallbecarriedoutafterputtingallmainbus-ductsontotheposition,checkdistancebetweenthebus-ductsofdifferentphases,ensurethatthebus-ductsbetweentheswitchgearsandthetransformersisstraightandinrightangles,checkelevationofcentrallineofthebus-ducts,ensurethatconnectionbetweenthebus-ductsandthetransformersortheswitchgearsarecorrect.3.7.6.Installationofthewallbearingstructure.InstallthewallbearingstructureonthecolumnAwallsaccordingtodrawingsofthebus-ductmanufactory..Weldthewallbearingstructureatoutdoorsideinordertosealafterassemblyofthebus-ducts.3.7.7.Adjustmentofthebus-ductsinallowableerror.Assemblycanbecarriedoutseparatelyinordertofacilitateadjustmentofdimension.Considerrequirementforwholeconnectionduringassembly.Whenerroroccur,errorshallbedistributedintoalljoints,shallnotbeconcentratedononejoint.Bus-ductsshallnotberevisedarbitrarily..Thebus-ductsshallbeputcorrectlyaccordingtothetablefordistributionofthesections,thedirectionandmarkfornumberingofthephasesequence.Longitudinalgapbetweencasingsofallphasesshallbedistributeduniformly..Thebus-barsandthecasingsshallbeconcentric,anderrorshallnotexceed5mm.Adjacentbus-barsandcasingsshallbealigned.Bus-barsandcasingsshallnotbestressedextraafterconnection..Checkandrecordinsulationresistancebetweenbusconductorsandcasingsafterassemblyofallbus-ducts..Theconstructionsiteshallbecleanduringassemblyofthebus-ductsinordertoprotectthebus-ductsfromdust.3.7.8.Hardconnectionforbus-ductsandcasings.Hardconnectionforbus-ductsshallbecarriedoutaccordingtodrawings..Checkifallpartsareinstalledcompletely,ifdimensionandpositionofallpartsarecorrect,priortoconnectthebus-barsandcasings..Removepaintandoxideonsurfacewithemerypaperorwirebrush,orcleanitwithalcoholorothercleanerpriortoconnection.3.7.9.Connectionofthegroundwire.Allsteelstructuresofthebus-ductsshallbeconnectedwiththegroundstrapusing95mm2groundwires..Theoutgoingterminalcaseofthegeneratorandallshortcircuitplatesofcasingsshallbeconnectedwiththegroundstrapusing95mm2groundwires..Thegeneratorneutralpointcubicle,PT&arrestercubicleshallbeconnectedwiththegroundstrapusing95mm2groundwires..Allexpansionjointsandsoftconnectionofthebus-ductsmustbeconnectedreliablyinordertoensurecontinuanceandcompletenessofthecasings.3.7.10.Cleaninside,close..Clearoffsmearandforeignmatterfrominnerwallofthecasings,surfacesoftheinsulators,andtheinnerconductorswithcleancottoncloth.Therearen'tanyforeignmattersinthebus-ducts.Blowdrypressedairintothebus-ductssoastocleandust..Theworkersshallweartheworkclotheswithoutbuttons,weartheworkcap,andweartheshoeswithsoftsoles,whentheyenterthebus-ducts.Thecleaningtoolsshallberecordedandtakeoutall.Avoiddamageinnerpartssuchastheinsulators..Thebus-ductsshallbecheckedandaffirmedbytheleadersofthesupervisorydepartment,theownerandtheconstructioncompanie
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 聘請保姆的合同范本
- 上門做飯員工合同范本
- 酒吧商鋪分租合同范本
- 電動汽車電池系統(tǒng)荷電狀態(tài)估計研究
- 印刷機項目籌資方案
- 非營利組織車輛維護方案
- 城市公共設(shè)施安全隱患排查及應(yīng)急方案
- 急診科工作職責(zé)與患者教育方案
- 贍養(yǎng)老人協(xié)議書范本
- 連衣裙購銷合同
- 2025年江蘇南京技師學(xué)院招聘工作人員19人高頻重點模擬試卷提升(共500題附帶答案詳解)
- 華東師大版七年級數(shù)學(xué)下冊“第1周周考”
- DBJ50-T-385-2023半柔性復(fù)合路面技術(shù)標(biāo)準(zhǔn)
- 職業(yè)院校教師人工智能素養(yǎng):內(nèi)涵流變、框架構(gòu)建與生成路徑
- 如何在初中數(shù)學(xué)教學(xué)中提升學(xué)生的核心素養(yǎng)
- (完整版)小學(xué)一年級數(shù)學(xué)20以內(nèi)進退位加減法(1600道題)計算卡
- 2025年包頭鐵道職業(yè)技術(shù)學(xué)院高職單招語文2018-2024歷年參考題庫頻考點含答案解析
- 北京2024年北京市測繪設(shè)計研究院面向應(yīng)屆生招聘筆試歷年參考題庫附帶答案詳解
- 2025年減速機齒輪項目投資可行性研究分析報告
- 走進李白校本 課程設(shè)計
- 2025新人教版英語七年級下單詞默寫單(小學(xué)部分)
評論
0/150
提交評論