Author:DennisMcCulloughCleanDesignPrinciples‘Do/Don’ts’forCIP/SIPMicro/CleanDesignDo-Don’tsareprimarilyreferencetrainingmaterials;forP&Gprojectexecution,alwaysrefertotheCleanDesignStandards.Micro/CleanDesignPrinciplesCleanDesignSpecsforCIP/SIP*DefinitionsPrinciplesDesign:InertMaterials316LSSRequirementsfortemperatureSurfacefinishRa<0.8microns(32micro-inches)SmoothsurfacesAvoidanceofbio-filmsPreventproduct/materialaccumulationWeldspolishedandgoodqualityAvoidanceofdeadlegsCIP/SIPDesignforCleaningefficiencyProtectedagainstcontaminationfromoutsideenvironment*CIP=Clean-inPlace;SIP=Sanitize-in-PlaceMINIMALRISK(=standardfornewequipment)MODERATERISKHIGHRISKSS316LSS316LowergradeSSFRPThermoplasticsMinimumRa0.8μm(32μinch)Ra0.8-1.0μm(32-42μinch)MuchhigherRaInternalweldsgroundsmoothandpolishedInternalweldsgroundsmoothInternalweldsnottreatedCheckyourMOCcompatibilitywithyourproduct&sanitizingagentwithCETL!Micro/CleanDesignPrinciplesCIP/SIP:MaterialsofConstructionMoredetails:SeeP&GCleanDesignStandardsoncGMPsite.Micro/CleanDesignPrinciplesCIP/SIPDesignCIP/SIPDefinitionsClean(Sanitary)Design–FoundationstartingpointforC&S(Cleaning&Sanitization)Cleaning-theprocessofremovingmaterialtoapre-determinedstandard,freefromdirt,pollution,contamination.(Requiredbeforesanitizationcanoccur)Sanitization–themethodofreducingthenumberofmicroorganismstoa“safelevel”whichwillnotthreatentheintegrityofproductsormaterialsItsoneoftheveryfewpreventativemicrobiologicalcontrolstrategieswecanuse.Micro/CleanDesignPrinciplesCIP/SIPDesignCleanable&Sanitizable:ThepreferredmethodforcleaningisCIP/SIP(cleaninplace,sanitizeinplace).ThepumpmaterialsofconstructionmustbeabletowithstandCIP&SIPcleaningagentsandtemperatures.
Specifythecleaningandsanitizationmethodtotheequipmentsupplier!!Micro/CleanDesignPrinciples*Note:whenusingrinsewateranalysisitisessentialthattheinitialcountoftherinsewaterdoesn’texceed10cfu/ml.CIP/SIPDesignCleaningCriteria:Lessthan1/1000thofthespecifieddoseoftheactivematerialpersquaremeterofsurfaceofthemanufacturingequipment.Lessthan10ppmofresidualproductpersquaremeter.Novisibleresiduesormaterialoverthecompletesurfaceoftheequipment.Micro/CleanDesignPrinciplesCIP/SIPDesignSanitization:Lessthan25colonyformingunits(CFU)per25sqcentimeters(10sqinches)ofsurface.Lessthan10CFUdifferenceintheingoingandoutgoingrinsewatersamples*.Absenceofobjectionableorganisms.Micro-CleanDesignPrinciplesMustcleaneffectivelybeforesanitizationManualorautomaticCleaning/Sanitizationwithminimumdisassemblyorre-assemblyofequipmentMicro/CleanDesignPrinciplesCIP/SIPDesignCIP/SIPPrinciplesDefinedprocess/procedureDefinedfrequencyValidatedaseffectiveMultiplemethods–temperature,hypochlorite,alcohol,ozonePerformancecritical–time,temperature,concentration,contactandexposureMicro/CleanDesignPrinciplesCIP/SIPDesignCIP/SIPPrinciplesTime:AllPipingmustbedesignedtoremainatsanitizationtemperature82C(180F)for30minutesTemperature:Allpipingmustbedesignedtoremainatsanitizationtemperature82C(180F)fornolessthan30minutes.Inthecaseofahotpurifiedwaterdistributionsystem,thesystemmustremainabove82C(180F)(Moistheat)*continuously.Forcoldpurifiedwater,thesystemmustbeprotectedwithaminimumozoneconcentrationof0.25ppmandmaintaincirculationthroughoutthesystem.Equipmentdesignspecificationswillrequiredesignsthatcansupporttheappropriatecleaningandsanitizationprocessasdictatedbyeithertheproductcategoryorthebusinessunit.*Typicalmoistheatishotwaterorsteam(2bar)maximumMicro/CleanDesignPrinciplesCIP/SIPDesignCIP/SIPPrinciples(cont.)Wherehotwaterandsteamcannotbeutilizedduetoexistingsystemconfiguration,orformulationconsiderations,chemicalsanitizationagentscanbevalidatedaseffective.Ifchemicalsanitizersaretobeusedthesystemandproductmustbeshowntobefullycompatiblewiththesanitizer.Note:UseofanyotherchemicalsanitizerrequiresagreementfromtheRegionalMicrobiologistandapprovalbythesite’schangereviewboard,priortopurchase.Personalprotectiveequipmentrequirementsmustbeidentified,priortostartofcleaningorsanitizingwithchemicals.Twocommonlyusedalternativestoheataredetailedbelowwithstandardchemicalconcentrationsandexposuretimes.Hypochloritesolution-minimumhypochloriteconcentrationof250ppmonspentfluidandnomorethana25ppmdropfromtheconcentrationintroducedintothesystem.Allequipmentbeingsanitizedmustbeexposedforminimum30minutes.Ethanol/IPA-minimum70%Ethanol/IPA/IPAconcentrationwith30minuteexposuretime.Micro/CleanDesignPrinciplesCIP/SIPDesignCIP/SIPPrinciples(cont.)Poorcleaning&sanitizationisamajorcontaminationriskThemostcommonrootcausesforcleaning/sanitizationfailuresareLackofsanitarydesignindevelopment/process/storage/packingequipment.InadequatecompletionoftheprocedurePoorchangecontrol–newproducts/repairsLackofawareness&understandingReblendandeffluentdisposalsystems
DiluteproductallowsbacterialadaptationMicro/CleanDesignPrinciplesCIP/SIPDesignInertMaterialsInerttoproduct,processconditionscleaning/sanitizingagentsNonreactive,additiveorabsorptiveStructuralconsiderationsProductdeterminesmaterialofchoiceStainlesssteel–316LSinglepolymerplastic-PE,PP,PTFESeals&gaskets-EPDM,PTFE,Viton,SiliconeAggressiveproducts/materials-TitaniumCostaconsiderationbutnottheconsiderationPseudomonas
sp.AccumulationonStainlessSteelMicro/CleanDesignPrinciplesCIP/SIPDesign“Don’t”Micro/CleanDesignPrinciples“Do”“Don’t”316L;SurfacefinishRa<0.8microns(32micro-inches)Poorsurfacefinishquality;leadstowatercollectionafterCIP/SIPGoodsurfacefinishquality<0.8microns;leadstohigherqualityCIP/SIPCIP/SIPDesignMicro/CleanDesignPrinciplesCIP/SIPDesignCleaningsystemadequatelydesigned:CleaningagenteffectiveforproductremovalSufficientpressure/flowDesign-locationofsprayballsSystemdesignedtoallowaccesstoallcontactparts:Noproductaccumulation(connections!)Simplifieddesign(maintainingCD*standards)Pipingslope/equipmentdrainabilityNothingoverheadproductzonesNodeadlegs*CleanDesignStandardsShadowAreaMicro/CleanDesignPrinciplesCIP/SIPDesignCIP/SIPDesign:Sprayballcleaningefficiency“Don’t”Micro/CleanDesignPrinciples“Don’t”TankDesign:Jet-ball-Cleaningefficiencyisbetter*
*Note:Considerationneedstobegiventosprayballdesignandselectionforapplicationsinvolvingcorrosivematerialsduetopotentialissueswithcrevicecorrosionwhichcouldcauserotatingsprayballstobecomeinoperable.Therefore,specialdesignsofstationarysprayballsmayberequiredtoavoidthisproblemandtostillensurefullcleaningofthetank.“Do”CIP/SIPDesign“Do”Micro/CleanDesignPrinciplesCIP/SIPDesign:UtilizeVendormodelingcapabilitiesforpropersprayballselectionandpositionCIP/SIPDesignExistingSystemStorageTanksDayTanksFiller3Storagetanks5daytanks4-5pumps16-20by-passes80+valves3Mainpipelines-approx60meterslengthOver50othersectionofpipe-jointed1.5mofpipe-6valves&4strainers6weekstoclean&sanitizeMicro/CleanDesignPrinciplesCIP/SIPDesign“Don’t”StorageTanksFillerManifold3x60mlengthofpipeContinuouslyweldedThreepump20valvesIncreasedflexibilityReducedchangeovertime5minutesClean/sanitize=1hour(Systemscanbecleanedandsanitisedseparately)Micro/CleanDesignPrinciplesDesignpipingtoequipmentforsimplicity—Note:ManualmanifoldscanpresentcleandesignrisksCIP/SIPDesignManifoldExecutions:-CleanDesign-PresentQARisk-Requirepre-approvalfromMicrobiology-”Better”systemisAuto-Manifold“Do”Provideequipmentsimplicity“Don’t”CreateQA/Microrisks—cleandesignappliedtomanifolddesign“Do&Don’t”Micro/CleanDesignPrinciplesManifoldExample:Internalmanifoldsmustbedesignedwithinternalslopetopromotedrainability&designedfor“pokeyoke”—toensurepipefittingsonlymatchtoonesystemtoavoidQArisk“Don’t”CIP/SIPDesignMicro/CleanDesignPrinciplesDesignpipingtopromotedrainabilityforequipment“Do”CIP/SIPDesignPumpMMTankBottomMillNewSimplifiedDesignToHXMicro/CleanDesignPrinciplesPumpMMTankBottomMillToHXCIP/SIPDesign“Do”“Don’t”O(jiān)riginalDesignDesignpipingtopromotedrainabilityforequipmentPumpFMTankBottomMicro/CleanDesignPrinciplesPumpFMTankBottom“Do”“Don’t”DesignpipingtopromotedrainabilityforequipmentNewSimplifiedDesignOriginalDesignCIP/SIPDesignCIP/SIPDesignMicro/CleanDesignPrinciplesAvoidpipingdirectoverproductzones“Don’t”DeadLegdesignprinciplesMicro/CleanDesignPrinciplesCIP/SIPDesign“Do”DeadLeg1DeadLeg2Micro/CleanDesignPrinciplesCIP/SIPDesignAvoid“DeadLegs”inpipingdesign“Don’t”CriticalFactors–newfindingsWashoutWaterVelocityPipediameterPresenceofdeadlegsLocationofdeadlegsrelativetoanelbowPositionofdeadlegsrelativetowaterflowMicro/CleanDesignPrinciplesCIP/SIPDesignTerminologyx=deadlegpositionDirectionofwaterflowInSideOutSide(ISOS)(hardtoclean)InSideOutBase(ISOB)(easytoclean)InBaseOutSide(IBOS)(moderate)Deadlegrotationrelativetohorizondidnotappeartoaffectwashoutdurations.Micro/CleanDesignPrinciplesCIP/SIPDesignPoorwash-outpipingdesign1"drainToProcess1tontankPITTITToProcess3"1"RO/DIWaterinjection3"PipingSprayballWaterSupply1"drain1"drain213HypotheticalPoorWashoutSequenceStepDescriptionDuration(s)1Sprayballemptytank,pumpouttodrain602CyclePSVtocleanPSVseat,cleanpumpusingwaterinjectionandrunningpumpathighoutput1803OpenPSVandtocleandownstreampiping.Cyclethroughdrains,thenopenalldrains.2404Drainentiresystem30Totalwashouttime8:30Waterpumpedfromtanktowashoutdownstreampipingwouldresultinineffectivecleaningofpiping.Long,multipledeadlegsinISOSpositionNumerous1”drainpointsdonotallowconsistentwash-watervelocity.Waterflowisrestrictedthrough1”waterinjectionanddrains.Usingprocesspumptodrivewatermaylimitwatervelocity.xMicro/CleanDesignPrinciples“Don’t”Betterwash-outpipingdesign2"RO/DIWaterinjection1tontankPITTIT2"drain3"PipingProcessProcess3"2"drainSprayballWaterSupply1a21b31cMicro/CleanDesignPrinciplesAlldeadlegsareinISOBposition,includinginstrumenttees.Lowflowthroughtanksprayballshasminimalimpactonwaterinjectiontopiping.Redundantdrainvalvesremovedfromsystem.Deadlegdistancesareshortenedasmuchaspossible.Upsizedwaterinjectionsanddrainallowadequatewatervelocitythrough3”pipe.HypotheticalBetterWashoutSequenceStepDescriptionDuration(s)1aSprayballemptytank451bCyclePSVtocleanPSVseat151cAfterPSViscleaned,cleanpumpusingwaterinjectionandrunningpumpathighoutput302OpenPSVtocleandownstreampipingusingwaterpressure303ClosePSVandcleanthroughtankblockvalve154Drainentiresystem30Totalwashouttime2:45“Do”Micro/CleanDesignPrinciplesCIP/SIPDesignPrinciplesforeffectivewash:CleaningWaterFlowrate:ForallbusinesscategoriesandproductstheflowratemustbeturbulentatReynoldsnumber>3000(typically;1-1.5m/sec(3-5ft/sec))relativetothesurfacetobecleanedfortheCIPproceduretobeeffective.Higherflowratesimpartingmoreenergy/turbulenceand/orelevatedwatertemperaturemayberequiredforsomeproductcategoriesforexampleviscousmaterialsneedatleast2.5-3meterspersecond(8-10ft/sec)foreffectivewashout.TherequiredflowratemustbedeterminedexperimentallyorviamodelingandfinallyvalidatedaspartoftheCleaning&Sanitizationvalidation.Whateverflowrateusedmustbesufficienttoremoveallproductresiduesthatmayinhibiteffectivesanitization.Ineffectivecleaningwillalsoincreasetheriskofcorrosionduringsanitizationduetotheelevatedtemperaturesandproductresidues.“Do”Micro/CleanDesignPrinciplesCIP/SIPDesignCleanDesignSpecsforCIP/SIPDesign:PrinciplesforeffectivewashMaximizingwashwatervelocityisthemostsignificantfactorforeffectivewashouts–especiallyincaseswheredeadlegsexist.Eliminatedeadlegswherepossible;otherwisekeepdeadlegstominimumL/DratioorpositiondeadlegsinISOBposition.Increasingwash-watervelocityresultsindecreaseinwaterconsumption.PDpumpsshouldrunnearfulloutputduringcleaningtominimizetimetocleanpumpinternals“Do”MaximizingvelocityMicro/CleanDesignPrinciplesHighervelocity=reductionofwaterusagePipesizeVelocitym/sflowrate(gpm)duration(sec)waterusage(gal)Waterreduction3",nodeadlegs21454110070%3",nodeadlegs3.5253730Micro/CleanDesignPrinciplesEquipmentfindingsStaticSprayballDesignMechanicalSprayballDesignSavingsSprayballtypeDuration(min)Waterusage(tons)Duration(min)Waterusage(tons)Time(min)Waterusage(tons)Washout201.58.712.8Sanitizations303.6301.102.5Micro/CleanDesignPrinciplesCIP/SIPDesignPDpumps:PDpumpsshouldrunnearfulloutputduringcleaningtominimizetimetocleanpumpinternals.TankCleaningLeveragevendormodelingtohelpdeterminebestsprayballdesignandoperatingsequencetocleantanks.Partiallyfillw/agitatorrunning,drainfirst(sprayballineffectivebelowwaterline),don’tcleaninlet&tankatthesametime“Do”TipsforwashoutsequenceMicro/CleanDesignPrinciplesCIP/SIPDesignForwashoutsequences,breakupsystemsintocircuitstomaximizeavailablewashwatercapacity.SeparateentiresystemsintocircuitsandevaluatewaterflowsandvelocitiestoensurethattargetvelocitiescanbeachievedthrougheachcircuitGenerally,cleancircuitsclosesttothewatersourcefirst.Thenmovetonextcircuitfartheraway.Noparallelflowpathshouldbeusedinacircuitunlesssufficientwatervelocityisassuredinallpaths.Avoidcontaminatingcleancircuitsbyensuringthatcircuitsthatarebeingcleaneddonotdrainthroughcircuitsthathavealreadybeencleaned.“Do”PipingdesignforwashoutMicro/CleanDesignPrinciplesCIP/SIPDesignConsiderwashoutwhenP&IDsaredevelopedandwhencompletingpipingdetaildesign.UseshortTeesvs.standardlengthTees.Be
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 黑土坡治理施工方案
- aq2006尾礦庫安全技術(shù)規(guī)程
- 玻璃橋維護施工方案
- 2025年蘭考三農(nóng)職業(yè)學(xué)院單招職業(yè)傾向性測試題庫審定版
- 2025年黃河交通學(xué)院單招職業(yè)適應(yīng)性測試題庫及參考答案
- 2025年重慶市樂山市單招職業(yè)適應(yīng)性測試題庫帶答案
- 2025年大慶醫(yī)學(xué)高等??茖W(xué)校單招職業(yè)適應(yīng)性測試題庫參考答案
- 2025年哈爾濱傳媒職業(yè)學(xué)院單招職業(yè)技能測試題庫新版
- 5 g k h 教學(xué)設(shè)計-2024-2025學(xué)年語文一年級上冊統(tǒng)編版
- 環(huán)境科學(xué)與工程環(huán)境保護法規(guī)及案例分析試卷解析
- 15J403-1-樓梯欄桿欄板(一)
- 4.2 歌曲 《小小少年》課件(8張)
- 武漢版生命安全教育一年級-第19課《做好“四勤”防疾病》課件
- 小學(xué)教案、作業(yè)常規(guī)檢查方案
- 2024教培合作簡單協(xié)議書
- 公司集團保安服務(wù) 投標(biāo)方案(技術(shù)方案)
- 2024年中級纖維檢驗員職業(yè)鑒定考試題庫(含答案)
- 水利水電工程單元工程施工質(zhì)量驗收評定表及填表說明
- YYT 0661-2017 外科植入物 半結(jié)晶型聚丙交酯聚合物和共聚物樹脂
- 人教版版五年級數(shù)學(xué)下冊 第二單元綜合測試卷
- 2024年阜陽職業(yè)技術(shù)學(xué)院單招職業(yè)適應(yīng)性測試題庫附答案
評論
0/150
提交評論