UL964
STANDARDFORSAFETYElectricallyHeatedBedding
ONI7NWOd-NOISSIWa3dINOHLIMNOIINalaISIaxONOI1onaodd3dd3HL8N=XO=a3ZIAOHLNV1ON-7VI&3⊥VWa3⊥HOId人d007N
SEPTEMBER18,2020-UL964
tr1
ULStandardforSafetyforElectricallyHeatedBedding,UL964TwelfthEdition,DatedAugust31,2011
SummaryofTopics
ThisrevisionofUL964datedSeptember18,2020includesanewSupplementSAwith
requirementsthatcoverremotelyoperatedelectricallyheatedbedding,includingsmartenabled.
TextthathasbeenchangedinanymannerorimpactedbyUL'selectronicpublishingsystemismarkedwithaverticallineinthemargin.
ThenewrequirementsaresubstantiallyinaccordancewithProposal(s)onthissubjectdatedMarch27,
2020andJuly15,2020.
Allrightsreserved.Nopartofthispublicationmaybereproduced,storedinaretrievalsystem,ortransmittedinanyformbyanymeans,electronic,mechanicalphotocopying,recording,orotherwisewithoutpriorpermissionofUL.
ULprovidesthisStandard"asis"withoutwarrantyofanykind,eitherexpressedorimplied,includingbutnotlimitedto,theimpliedwarrantiesofmerchantabilityorfitnessforanypurpose.
InnoeventwillULbeliableforanyspecial,incidental,consequential,indirectorsimilardamagesincludinglossofprofits,lostsavings,lossofdata,oranyotherdamagesarisingoutoftheuseofortheinabilitytousethisStandard,evenifULoranauthorizedULrepresentativehasbeenadvisedofthepossibilityofsuchdamage.InnoeventshallUL'sliabilityforanydamageeverexceedthepricepaidforthisStandard,regardlessoftheformoftheclaim.
UsersoftheelectronicversionsofUL'sStandardsforSafetyagreetodefend,indemnify,andholdULharmlessfromandagainstanyloss,expense,liability,damage,claim,orjudgment(includingreasonableattorney'sfees)resultingfromanyerrorordeviationintroducedwhilepurchaserisstoringanelectronicStandardonthepurchaser'scomputersystem.
ULCOPYRIGHTEDMATERIAL-NOTAUTHORIZEDFORFURTHER
REPRODUCTIONORDISTRIBUTIONWITHOUTPERMISSIONFROMULINC.
tr2SEPTEMBER18,2020-UL964
NoTextonThisPage
ULCOPYRIGHTEDMATERIAL-NOTAUTHORIZEDFORFURTHER
REPRODUCTIONORDISTRIBUTIONWITHOUTPERMISSIONFROMULINC.
AUGUST31,2011
(TitlePageReprinted:September18,2020)
1
UL964
StandardforElectricallyHeatedBedding
FirstEdition-May,1933
SecondEdition-June,1935
ThirdEdition-September,1942
FourthEdition-October,1950
FifthEdition-December,1954
SixthEdition-November,1968
SeventhEdition-September,1975EighthEdition-August,1981
NinthEdition-March,1988
TenthEdition-November,1994EleventhEdition-January,2000
TwelfthEditionAugust31,2011
ThisANSI/ULStandardforSafetyconsistsoftheTwelfthEditionincludingrevisionsthroughSeptember18,2020.
CommentsorproposalsforrevisionsonanypartoftheStandardmaybesubmittedtoULatanytime.ProposalsshouldbesubmittedviaaProposalRequestinUL'sOn-LineCollaborativeStandardsDevelopmentSystem(CSDS)at
.
UL'sStandardsforSafetyarecopyrightedbyUL.NeitheraprintednorelectroniccopyofaStandardshouldbealteredinanyway.AllofUL'sStandardsandallcopyrights,ownerships,andrightsregardingthoseStandardsshallremainthesoleandexclusivepropertyofUL.
COPYRIGHTO2020UNDERWRITERSLABORATORIESINC.
ULCOPYRIGHTEDMATERIAL-NOTAUTHORIZEDFORFURTHER
REPRODUCTIONORDISTRIBUTIONWITHOUTPERMISSIONFROMULINC.
2UL964SEPTEMBER18,2020
NoTextonThisPage
ULCOPYRIGHTEDMATERIAL-NOTAUTHORIZEDFORFURTHER
REPRODUCTIONORDISTRIBUTIONWITHOUTPERMISSIONFROMULINC.
SEPTEMBER18,2020UL9643
CONTENTS
INTRODUCTION
1Scope 5
2Components 5
3UnitsofMeasurement 6
4UndatedReferences 6
5Glossary 6
CONSTRUCTION
6CoveringofElectricalParts 7
7Insulation 7
8Spacings 8
9TemperatureLimitation 9
10ControlUnits 1
11Switches 14
12InternalWiring 14
13Supply,Control,Pigtail,andInterconnectingCords 14
14Connections 18
PERFORMANCE
15General 19
16InputTest 21
17ControlImpactandCalibrationTest 21
18ControlUnitsTests 21
19NormalTemperatureTest 23
19.1Blankets,sheets,quilts,andcomforters 23
19.2Mattresses,footwarmers,andmattresspads 23
20FlexingTest 25
20.1General 25
20.2Flexingofmattresses 29
21ConnectorFlexingTest 29
22ThrowBlanketCordFlexingTest 31
23LeakageCurrentTest(AllProductsExceptMattresses) 33
24DielectricVoltage-WithstandTest(AllProductsExceptMattresses) 33
25Laundering(AllProductsExceptMattresses) 34
26RollerFlexingTest(Mattresses,MattressPads,andFootWarmers) 34
27LeakageCurrentTest-Repeated(AllProductsExceptMattresses) 35
28DielectricVoltage-WithstandTest-Repeated(AllProductsExceptMattresses) 35
29NormalTemperatureTest-Repeated(AllProducts) 35
30ImmersionTest(Blankets,Sheets,Quilts,andComforters) 35
31AbnormalTemperatureTests 35
31.1General 35
31.2Firstmethodoffolding 36
31.3Secondandthirdmethodoffolding 38
31.4Threethicknessandfivethicknessfold 39
31.5Multi-thicknessfold 41
31.6Bunchtest 41
31.7Fullyblanketed 44
318/Disabledcontrol aπ后DIA.MOπ.AITMODI7EN.EAn.ERTMG0.44
32D.0To L
R
33FinalMattressTests..TRIBUTIONwTH0UTPERI2Ssi…NFR…U46
4
UL964SEPTEMBER18,2020
34FlammabilityofShells 46
35EaseofIgnitionTest 56
36EffectofCleaningSolventsonBeddingTests(AllProductsExceptMattresses) 59
37ThermostatsinBedding 60
38AbnormalOperationTestforProductsEmployingSemiconductorHeaterWire 63
39Push-BackStrainReliefTest 64
MANUFACTURINGANDPRODUCTIONLINETESTS
40PolarizationContinuityCheckTest 64
RATINGS
41Details 65
MARKINGS
42Details 65
SUPPLEMENTSA-REMOTEANDDELAYEDSTARTSCHEDULINGELECTRICALLYHEATED
BEDDING
INTRODUCTION
SA1Scope 69
SA2Glossary 69
CONSTRUCTION
SA3Controls-General 70
SA4ResistancetoElectroMagneticPhenomena(Immunity) 70
MARKINGSANDINSTRUCTIONS
SA5General 71
APPENDIXA
StandardsforComponents 72
ULCOPYRIGHTEDMATERIAL-NOTAUTHORIZEDFORFURTHER
REPRODUCTIONORDISTRIBUTIONWITHOUTPERMISSIONFROMULINC.
SEPTEMBER18,2020UL9645
INTRODUCTION
1Scope
1.1Theserequirementscoverelectricallyheatedblankets,comforters,quilts,sheets,mattresspads,mattresses,footwarmers,throwblanketsandsimilarbedding.
1.2TheseproductsareforuseinaccordancewiththeNationalElectricalCode,ANSI/NFPA70,onsingle-phasealternating-currentsupplycircuitsoperatingatanominalpotentialof110to120Vac.
1.3Allbeddingiscord-connectedandissuppliedwitheitheraswitchoroneortwouser-adjustabletemperature-controlunits.Beddingmaybethermostaticallycontrolled.
1.4Beddingintendedforconnectiontootherthananominal120Vacsupplyvoltage,andbeddingforusewithwaterbeds,mechanicalbedsandthelike,aretobesubjecttoadditionalinvestigation,with
considerationgiventotheirintendeduse.
2Components
2.1Acomponentofaproductcoveredbythisstandardshall:
a)Complywiththerequirementsforthatcomponentasindicatedinthisstandard;
b)Beusedinaccordancewithitsrating(s)establishedfortheintendedconditionsofuse;c)Beusedwithinitsestablisheduselimitationsorconditionsofacceptability;
d)Additionallycomplywiththeapplicablerequirementsofthisendproductstandard;ande)Notcontainmercury.
Specificcomponentsareincompleteinconstructionfeaturesorrestrictedinperformancecapabilities.Suchcomponentsareintendedforuseonlyunderlimitedconditions,suchascertaintemperaturesnotexceedingspecifiedlimits,andshallbeusedonlyunderthosespecificconditions.
ExceptionNo.1:Acomponentofaproductcoveredbythisstandardisnotrequiredtocomplywithaspecificcomponentrequirementthat:
a)Involvesafeatureorcharacteristicnotrequiredintheapplicationofthecomponentintheproduct;
b)Issupersededbyarequirementinthisstandard;or
c)Isseparatelyinvestigatedwhenformingpartofanothercomponent,providedthecomponentisusedwithinitsestablishedratingsandlimitations.
ExceptionNo.2:Acomponentcomplyingwithacomponentstandardotherthanthosecitedinthisstandardisacceptableif:
a)Thecomponentalsocomplieswiththeapplicablecomponentstandardidentifiedinthisstandard;or
b)Thecomponentstandard:
ULCO1)7scompatiblewiththeampacityandovercurrentprotection
REPRODUwhereappropriate;TPERM
requirements'NFPA70,NFROMULI
6
UL964SEPTEMBER18,2020
2)Considerslong-termthermalpropertiesofpolymericinsulatingmaterialsinaccordancewithPolymericMaterials-LongTermPropertyEvaluations,UL746B;and
3)Anyuselimitationsoftheothercomponentstandardisidentifiedandappropriatelyaccommodatedintheenduseapplication.Forexample,acomponentusedinahouseholdapplication,butintendedforindustrialuseandcomplyingwiththerelevantcomponentstandardmayassumeuserexpertisenotcommoninhouseholdapplications.
2.2Acomponentthatisalsointendedtoperformotherfunctions,suchasovercurrentprotection,ground-faultcircuit-interruption,surgesuppression,anyothersimilarfunctions,oranycombinationthereof,shallcomplyadditionallywiththerequirementsoftheapplicablestandard(s)thatcoverdevicesthatprovidethosefunctions.
Exception:Wheretheseotherfunctionsarenotrequiredfortheapplicationandnotidentifiedaspartofmarkings,instructions,orpackagingfortheappliance,theadditionalcomponentstandard(s)neednotbeapplied.
2.3Acomponentnotanticipatedbytherequirementsofthisstandard,notspecificallycoveredbythecomponentstandardsidentifiedinthisstandard,andthatinvolvesapotentialriskofelectricshock,fire,orpersonalinjury,shallbeadditionallyinvestigatedinaccordancewiththeapplicablestandard.
2.4Withregardtoacomponentbeingadditionallyinvestigated,referencetoconstructionandperformancerequirementsinanotherendproductstandardisappropriatewherethatstandardanticipatesnormalandabnormaluseconditionsconsistentwiththeapplicationofthisstandard.
2.5MaterialsusedinaClass105(A)insulationsystemshallcomplywiththeNormalTemperatureTest,Section19.MaterialsusedinaninsulationsystemthatoperatesaboveClass105(A)temperaturesshalcomplywiththeStandardforSystemsofInsulatingMaterials-General,UL1446.
3UnitsofMeasurement
3.1Valuesstatedwithoutparenthesesaretherequirement.Valuesinparenthesesareexplanatoryorapproximateinformation.
4UndatedReferences
4.1Anyundatedreferencetoacodeorstandardappearingintherequirementsofthisstandardshallbeinterpretedasreferringtothelatesteditionofthatcodeorstandard.
5Glossary
5.1ForthepurposesofthisStandard,thefollowingdefinitionapplies.
5.2CLASS2SUPPLY-AsecondarycircuitsuppliedbyaClass2powersupplythatcomplieswiththeStandardforClass2PowerUnits,UL1310.
5.3LOW-VOLTAGECIRCUIT-Acircuitinvolvingapotentialofnotmorethan30voltsandsuppliedbyaprimarybattery,byastandardClass2transformer,orbyacombinationofatransformerandafixedimpedancethat,asaunit,complieswithalltheperformancerequirementsforaClass2transformer.Acircuitderivedfromaline-voltagecircuitbyconnectingresistanceinserieswiththesupplycircuitasa
meansoflimitingthevoltageandcurrentisnotconsideredtobealow-voltagecircuit.
ULCOPYRIGHTEDMATERIAL-NOTAUTHORIZEDFORFURTHER
REPRODUCTIONORDISTRIBUTIONWITHOUTPERMISSIONFROMULINC.
7
UL964
SEPTEMBER18,2020
5.4SEMICONDUCTORHEATERWIRE-Aheatingelementconsistingoftwoconductorsseparatedbyaconductivematerialwhichhasarapidnon-linearincreaseinresistancewhenthetemperatureisraisedthroughaparticularrange.
5.5THROWBLANKET-Anelectricblanketintendedforuseinindoorlocationsbutnotspecificallyforuseonlyonbeds.Electricthrowblanketsaretypicallysmallerinoverallsizethanblanketsintendedforuseonbeds.Thelengthistypicallylessthan75inches(109.5cm)and/orthewidthistypicallylessthan38inches(96.5cm).
CONSTRUCTION
6CoveringofElectricalParts
6.1Exceptfortheconnectorattachedtothebedding,allelectricalpartsofthebeddingshallbeenclosedinashellorothercoveringofafabricinwhichtherearenoopenings.Allstuffing,padding,springs,andsimilarnonelectricalcomponentsofbeddingshallbeoutsidethiscoveringandshallnotbedetrimentaltothecoveringoritselectricalcontents.
6.2Allseamsinthefabricenclosingelectricalpartsshallbestronglystitchedorotherwiseequivalentlysecured.
7Insulation
7.1Electricalinsulationistobeconsideredwithrespecttoitsacceptabilityfortheparticularapplication.Ifitisnecessarytoinvestigateamaterialtodeterminewhetheritisacceptable,considerationistobegiventoitsmechanicalstrength,dielectricproperties,insulationresistance,heat-resistantqualities,thedegreetowhichitisenclosedorprotected,andanyotherfeatureshavingabearingontheriskoffire,electricshock,andinjurytopersonsinvolved,inconjunctionwithconditionsofactualservice.Allofthesefactorsaretobeconsideredwithrespecttothermalaging.
7.2Ordinaryvulcanizedfibermaybeusedforinsulatingbushings,washers,separators,andbarriersbutnotasthesolesupportforuninsulatedlivepartswhereshrinkage,currentleakage,orwarpagemayintroduceariskoffireorelectricshock.Thermoplasticmaterialsarenotconsideredtobeacceptableforthesolesupportofuninsulatedliveparts,unlesstheyhavebeenfoundtohavethenecessarystrengthandrigidity,resistancetoheat,resistancetoflamepropagation,dielectricproperties,andotherpropertiesacceptablefortheapplication.Allofthesefactorsaretobeconsideredwithrespecttothermalaging.
7.3Aninsulatinglinershallbeacceptableforthepurpose.Vulcanizedfiberorasimilarmaterialemployedwherespacingswouldotherwisebeunacceptableshallbe1/32inch(0.8mm)thickorthicker,andshallbesolocatedorofsuchmaterialthatitcannotbeadverselyaffectedbyarcing.However,164inch(0.4mm)orthickervulcanizedfiberisacceptableinconjunctionwithanadditionalairspacingof50percentormoreofthespacingrequiredforairalone.Barriersshallbesecuredinplacebyameansotherthanfrictionbetweensurfaces.Theelasticityoftubingshallnotbedependedupontoholdthetubinginplace.
7.4Theheatingelementshallbeelectricallyinsulatedforitsentirelengthsothatitisnotincontactwiththeshellorothercoveringfabricatanypoint.Theinsulatedheatingelementshallbeappliance-wiringmaterialacceptablefortheapplication.Theinsulatedheatingelementshallbesosecuredinpositionthatthereisnounduestressonitduringuse,handling,andcleaningofthebedding.Atleast9inches(229mm)ofthefootofablanket,sheet,quiltorcomforterthatcanbetuckedinduringnormaluseshallbedevoidofallelectricalpartsotherthanthemalehalfofthebeddingconnectorandtheportionofthe
TAUTHORIZEDFORFURTHER
insulatedheatingelementleadingtotheconnector.L一
REPRODUCTIONORDISTRIBUTIONWITHOUTPERMISSIONFROMULINC.
8UL964SEPTEMBER18,2020
Exception:Beddingconstructedwithself-limitingsemiconductorheaterwireisabletobeprovidedwithelectricalpartstotheperimeterofthebedding.
7.5Heaterwire,includingsemiconductorheaterwire,shallcomplywiththeReferenceStandardforElectricalWires,Cables,andFlexibleCords,UL1581.Semiconductorheaterwireshalladditionallycomplywiththerequirementsforthermistor-typedevices,UL1434.
7.6Flexuralreliefshallbeprovidedfortheconductorsthatexitthemale-connectorbodyofablanketsheet,quilt,orcomforter.
7.7Eachthermostatandotherlivepartwithintheshellorothercoveringfabricshallnothaveanysharpedgesandshallbeelectricallyinsulatedwithinsulatingtubingacceptableforthevoltageandtemperatureinvolved.Theinsulationoneachpartshallbe:
a)Bonded,awatertightsealisrequired,totheinsulationontheheatingelementorotherwiringconnectedtothepart;and
b)Atleastasthickatthebondandelsewhereastheinsulationontheheatingelementorotherwiringconnectedtothepart.
7.8Aspliceinwiringwithinathermostatshallbeinsulatedifpermanenceofspacingfromthesplicetoothermetalpartsofthethermostatisnotprovided.
7.9PolymericelectricalinsulatingmaterialsandenclosuresshallcomplywiththeapplicablerequirementsoftheStandardforPolymericMaterials-UseinElectricalEquipmentEvaluations,UL746C.
7.10Therequirementsforsupplementalinsulation(e.g.tape,sleevingortubing)arenotspecifiedunlesstheinsulationordeviceisrequiredtofulfll7.1-7.4oraperformancerequirementofthisstandard.Insuchcases:
a)InsulatingtapeshallcomplywiththeStandardforPolyvinylChloride,Polyethylene,andRubberInsulatingTape,UL510;
b)SleevingshallcomplywiththeStandardforCoatedElectricalSleeving,UL1441;
c)TubingshallcomplywiththeStandardforExtrudedInsulatingTubing,UL224.
8Spacings
8.1Exceptasindicatedin8.2-8.4,oversurfaceandthrough-airspacingsnosmallerthan1/16inch(1.6
mm)shallbemaintainedfromuninsulatedlivepartsto:a)Uninsulatedlivepartsofoppositepolarity;andb)Accessiblemetalparts.
Exception:Thespacingsmaybelessthanspecifiedin8.1ifincompliancewiththeStandardforInsulationCoordinationIncludingClearancesandCreepageDistancesforElectricalEquipmentUL840.Thefollowingparametersshallbeusedunlessthemicroenvironmentisfurtherevaluatedandfoundtocomplywithotherparameters:
a)OvervoltageshallbeIl;
b)PollutionDegreeshallbe2;andREPRCc)MaterialGrouplHb.DISTRIB
AL-NOTAUTHORIZEDFORFURTHER
TIONWITHOUTPERMISSIONFROMULINC.
SEPTEMBER18,2020UL9649
IfacircuitemploysavoltagelimitingdeviceforapplicationoftherequirementsintheStandardforInsulationCoordinationIncludingClearancesandCreepageDistancesforElectricalEquipmentUL840,thedeviceshallcomplywiththeStandardforSurgeProtectiveDevices,UL1449.
8.2Withinathermostat,exceptatthecontacts,thespacingsbetweenuninsulatedlivepartsonoppositesidesofthecontactsshallnotbelessthan1/32inch(0.8mm)throughairand3/64inch(1.2mm)overthesurfaceofinsulatingmaterial.
8.3Thespacingsmentionedin8.1and8.2donotapplytotheinherentspacingsofacomponent.Suchspacingsaretobeconsideredundertherequirementsforthecomponentinquestion.
8.4Atclosed-inpointsonly,suchasthescrew-and-washerconstructionofaninsulatedterminalmountedinmetal,aspacingof3/64inch(1.2mm)isacceptable.
9TemperatureLimitation
9.1Beddingshallbeprovidedwithmeanstoprecludetheattainmentofunacceptabletemperatures,see
19.1.1-19.1.3and31.1.1,onanypartofthebedding.
9.2Meanstoaverttheattainmentofunacceptabletemperaturesmaybeinherentintheconstructionofbedding-suchasalow-wattageheatingelement-thusnecessitatingnothermostatsorexternalcontrol.
9.3Thermostatsshallbedurable,reliable,uniforminoperation,andsufficientlysensitivefortheirintendeduseasdeterminedbycompliancewithThermostatsinBedding,Section37,andotherapplicablerequirements.
9.4Ifproperperformanceofathermostatdependsupontheintegrityofaclosedchamber,theconstructionshallprecludemoistureleaks,whichmayaffecttheuniformityandreliabilityofoperation.
9.5Athermostatinthebeddingshallnotbeadjustablebytheuserofthebeddingandshallbecoveredorsealedtoprecludetheentranceofdirtandlint.
9.6Materialsemployedinathermostatshallnotbeaffectedadverselybyanyoperatingconditionspresentedbythetestsdescribedintheserequirements.
9.7Platedsteel,exceptthatthebimetalneednotbeplated,maybeusedforacurrent-carryingpartinathermostatprovidedthatthepartisprotectedbysupplementarymeans(suchassealedsleeving)against
anyconditionsinvolvingmoisturetowhichthethermostatmaybesubjectedduringuseandcleaningofthebedding.
9.8Ifthermostatsorothertypesofdiscretetemperaturesensingdevicesareusedinthebeddingitself,theyshallbesufficientinnumberinaccordancewith9.10,andshallbeappropriatelylocatedtoenablethebeddingtocomplywith9.9,19.1.1-19.1.3,31.1.1,31.4.1-31.4.3,31.6.1-31.6.4,31.6.6,and31.6.7.Nosectionoftheheatingelementshallbeinserieswithfewerthantwodiscretesensingdeviceswhenthermostatsorothertypesofdiscretesensingdevicesareemployed.
9.9Compliancewiththerequirementin9.8istobedeterminedbyappropriatetestingthat,inthecaseofasheet,overblanket,quilt,orcomforter,istoincludethebunchingtestdescribedin31.6.1-31.6.4,31.6.6and31.6.7.
9.10Ablanket,sheet,quilt,orcomforterincorporatingdiscretesensingdevicesandintendedforuseon
atwin,double,queenorking-sizebedshallcomplywitheachofthefollowing:DFCRFURTHER
REPRODUCTIONORDISTRIBTLONWIUTPERMISSIONFROMULINC.
10UL964SEPTEMBER18,2020
a)Atleast10discretesensingdevicesaretobeusedinasizeintendedforatwinbedandineachhalfofaking-sizebed.Twelveormoredevicesaretobeusedinasizeintendedforadoubleorqueen-sizebed.
Exception:Ablanket,sheet,quilt,orcomfortertestedasspecifiedin31.5.1and31.6.5mayemployfewersensors.
b)Thetoprowofdiscretesensingdevicesinasizeintendedforatwinbed,inasizeintendedforadoubleorqueenbed,andineachhalfofasizeintendedforaking-sizebedistobesecuredagainstmigrationduringuse,handling,andcleaningoftheproduct.
9.11Whenaproductemployingatemperaturecontrolsystememploysanelectroniccircuitintendedtoprovideadegreeofprotectionagainsttheriskoffire,electricshock,orinjuryifafaultshouldoccurinthewire,thecircuitshallcomplywiththerequirementsfortestsforSafety-RelatedControlsEmployingSolid-StateDevices,UL991.Whentheelectroniccircuitisprovidedwithafusewhichisintendedtoopenasaresultofafaultinthewire,renderingtheproductinoperable,thefuseshallcomplywiththeStandardforLow-VoltageFuses-Part1:GeneralRequirements,UL248-1,andtheStandardforLow-VoltageFuses-Part14:SupplementalFuses,UL248-14.
Exception:ControlscomplyingwiththeStandardforAutomaticElectricalControlsforHouseholdandSimilarUse,Part1:GeneralRequirements,UL60730-1,includingAnnexH,fulfillstheaboverequirementsoftheStandardforTestsforSafety-RelatedControlsEmployingSolid-StateDevices,UL
991.
9.12SoftwarereliedontocomplywiththisstandardshallcomplywiththeStandardforSoftwareinProgrammableComponents,UL1998.
Exception:ControlscomplyingwiththeStandardforAutomaticElectricalControlsforHouseholdandSimilarUse,Part1:GeneralRequirements,UL60730-1,includingAnnexH,fulfillstheaboverequirementsoftheStandardforTestsforSafety-RelatedControlsEmployingSolid-StateDevices,UL
991.
9.13AthermalcutoffshallcomplywiththeStandardforThermal-Links(ThermalCutoffs)forUseinElectricalAppliancesandComponents,UL60691.
9.14Thefollowingtestparametersaretobeusedintheinvestigationofthecircuitcoveredby9.11forcompliancewiththeStandardforTestsforSafety-RelatedControlsEmployingSolid-StateDevices,UL991:
a)Withregardtoelectricalsupervisionofcriticalcomponents,acontrollershallnotpermitelectricbeddingfromexceedingtemperaturelimitsspecifiedin19.1.1and19.1.2ofthisstandard.
b)Afieldstrengthof3VpermeteristobeusedfortheRadiatedEMITest.
c)TheCompositeOperationalandCyclingTestistobeconductedfor14daysattemperatureextremesof0℃(32°F)and25℃(77°F).
d)ExposureClassH3istobeusedfortheHumidityTest.e)Avibrationlevelof5gistobeusedfortheVibrationTest.
f)WhenaComputationalInvestigationisconducted,λ。shallnotbegreaterthan6failures/106hoursfortheentiresystem.TheOperationalTestistobeconductedfor14days.
ULCOPYRIGHTEDMATERIAL-NOTAUTHORIZEDFORFURTHER
REPRODUCTIONORDISTRIBUTIONWITHOUTPERMISSIONFROMULINC.
SEPTEMBER18,2020UL964
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負責。
- 6. 下載文件中如有侵權(quán)或不適當內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 機械式停車設(shè)備類型與選型考核試卷
- 護肩制造工藝與適用人群考核試卷
- 收音機接收設(shè)備電路分析與維修考核試卷
- 西藥批發(fā)企業(yè)人力資源管理挑戰(zhàn)與對策考核試卷
- 高鐵車組駕駛員技能提升考核試卷
- 紡紗廠環(huán)境管理與污染治理考核試卷
- 2024年度貴州省安全員之B證(項目負責人)題庫練習試卷A卷附答案
- 2024年度貴州省安全員之A證(企業(yè)負責人)提升訓練試卷B卷附答案
- 2024年度甘肅省安全員之A證(企業(yè)負責人)典型題匯編及答案
- 花卉布置合同(2篇)
- (完整版)10KV開關(guān)柜培訓課件
- 燈具設(shè)計(課堂PPT)課件(PPT 111頁)
- 曼浦漢克化工(上虞)有限公司年產(chǎn)370噸鉍、銦、鈷、鎳無機鹽、
- 消防系統(tǒng)維修保養(yǎng)及設(shè)施檢測技術(shù)方案
- 任務(wù)5-給水系統(tǒng)的工作工況
- 泵進出口法蘭的強度計算
- 設(shè)備交接清單(樣本)
- 數(shù)值分析(課堂PPT)
- 新人教版小學六年級英語(上冊)第三單元教案
- 專利意見陳述書模板
- M1U3 Police work開課
評論
0/150
提交評論