1、CE SAR Test ReportVariant CE SAR Test ReportReport No.:SE140924C06CApplicant:SPA CONDOR ELECTRONICSAddress:Zone dActivits Route de MSila Ilot 70 section 161 Bordj Bou Arreridj 34000Product:Mobile PhoneBrand:CONDORModel No.:PGN-506Standards:EN 50360:2001A1:2012 / IEC 62209-1:2005 / EN 62209-1:2006 EN

2、 50566:2013AC:2014 / IEC 62209-2:2010 / EN 62209-2:2010 EN 62479:2010Nov. 25, 2014Nov. 24, 2014 Nov. 26, 2014Sample Received Date:Date of Testing:CERTIFICATION: The above equipment have been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., China Branch - Dongguan Lab, and found compl

3、iance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the samples SAR characteristics under the conditions specified in this report. It should not be rep

4、roduced except in full, without the written approval of our laboratory. The client should not use it toclaim product certification, approval, or endorsement by A2LA or any government agencies.This report is issued as a supplementary report to BV ADT report no.: SE140924C06. The differences comparedw

5、ith original report are adding 2nd source of Earphone.Prepared By :Evonne Liu / SpecialistNo: 2951.01Approved By : Gordon Lin / Assistant ManagerReport Format Version 5.0.0 Report No. : SE140924C06CReference No.: 141126C03Page No.: 1 of 25Issued Date : Dec. 10, 2014This report is for your exclusive

6、use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this repo

7、rt are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the informatio

8、n that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue

9、within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-

10、compliance to the specification.CE SAR Test ReportTable of ContentsRelease Control Record31.2.3.Summary of Maximum SAR Value4Description of Equipment Under Test5SAR Measurement System63.13.2Definition of Specific Absorption Rate (SAR)6SPEAG DASY System63.2.1 Robot73.2.2 Probes83.2.3 Data Acquisition

11、 Electronics (DAE)83.2.4 Phantoms93.2.5 Device Holder93.2.6 System Validation Dipoles103.2.7 Tissue Simulating Liquids10SAR System Verification12SAR Measurement Procedure133.4.1 Area & Zoom Scan Procedure133.4.2 Power Drift Monitoring133.4.3 Spatial Peak SAR Evaluation143.4.4 SAR Averaged Methods143

12、.33.44.SAR Measurement Evaluation154.14.2EUT Configuration and Setting15EUT Testing Position153.4.5 EUT Setup Photos15Tissue Verification16System Verification16Conducted Power Results17SAR Testing Results223.8.1 SAR Results for Body-Worn (Separation Distance is 1.5 cm Gap)223.8.2 Simultaneous Multi-

13、band Transmission Evaluation224.34.44.54.65.6.7.Calibration of Test Equipment23Measurement Uncertainty24Information on the Testing Laboratories25Appendix A. SAR Plots of System Verification Appendix B. SAR Plots of SAR MeasurementAppendix C. Calibration Certificate for Probe and Dipole Appendix D. P

14、hotographs of EUTReport Format Version 5.0.0 Report No. : SE140924C06CReference No.: 141126C03Page No.: 2 of 25Issued Date : Dec. 10, 2014CE SAR Test ReportRelease Control RecordReport Format Version 5.0.0 Report No. : SE140924C06CReference No.: 141126C03Page No.: 3 of 25Issued Date : Dec. 10, 2014R

15、eport No.Reason for ChangeDate IssuedSE140924C06CInitial releaseDec. 10, 2014CE SAR Test Report1. Summary of Maximum SAR ValueNote:1.The SAR10g limit (2.0 W/kg for Head and Body) for general population/uncontrolled exposure is specified in Council Recommendation 1999/519/EC Annex II.According to EN

16、62479, SAR testing for Bluetooth is not required because its maximum output power is less than20 mW.2.Report Format Version 5.0.0 Report No. : SE140924C06CReference No.: 141126C03Page No.: 4 of 25Issued Date : Dec. 10, 2014ModeHighestBody SAR10g(1.5 cm Gap) (W/kg)GSM9000.803GSM18000.369WCDMA I0.26WC

17、DMA VIII0.309LTE 30.141LTE 70.388LTE 400.192.4G WLAN0.033BluetoothN/ACE SAR Test Report2.Description of Equipment Under TestNote:1. This report is issued as a supplementary report to BV ADT report no.: SE140924C06. The differences compared with original report are adding 2nd source of Earphone.2. Th

18、e above EUT information is declared by manufacturer and for more detailed features description please refersto the manufacturers specifications or Users Manual.List of Accessory:Report Format Version 5.0.0 Report No. : SE140924C06CReference No.: 141126C03Page No.: 5 of 25Issued Date : Dec. 10, 2014B

19、atteryBrand NameCONDORModel NameBGN-506Power Rating3.8Vdc, 1950mAhTypeLi-ionEarphoneBrand NameCONDORModel Name3.5Signal Line Type1.1 meter non-shielded cable without ferrite coreEUT TypeMobile PhoneBrand NameCONDORModel NamePGN-506Tx Frequency Bands (Unit: MHz)GSM900 : 880 915GSM1800 : 1710 1785 WCD

20、MA Band I : 1920 1980 WCDMA Band VIII : 880 915 LTE Band 3 : 1710 1785LTE Band 7 : 2500 2570LTE Band 40 : 2300 2400WLAN : 2400 2483.5Bluetooth : 2400 2483.5Uplink ModulationsGSM & GPRS : GMSK EDGE : 8PSK WCDMA : QPSKLTE : QPSK, 16QAM 802.11b : DSSS802.11g/n : OFDMBluetooth : GFSKMaximum AVG Conducte

21、d Power (Unit: dBm)GSM900 : 32.12GSM1800 : 28.48 WCDMA Band I : 24.08 WCDMA Band VIII : 24.66 LTE Band 3 : 22.52LTE Band 7 : 22.96LTE Band 40 : 22.76802.11b : 12.84802.11g : 11.41802.11n HT20 : 10.96802.11n HT40 : 10.15Bluetooth : 6.86Antenna TypeFixed Internal AntennaEUT StageIdentical PrototypeCE

22、SAR Test Report3. SAR Measurement System3.1 Definition of Specific Absorption Rate (SAR)SAR is related to the rate at which energy is absorbed per unit mass in an object exposed to a radio field. The SAR distribution in a biological body is complicated and is usually carried out by experimental tech

23、niques or numerical modeling. The standard recommends limits for two tiers of groups, occupational/controlled and general population/uncontrolled, based on a persons awareness and ability to exercise control over his or her exposure. In general, occupational/controlled exposure limits are higher tha

24、n the limits for general population/uncontrolled.The SAR definition is the time derivative (rate) of the incremental energy (dW) absorbed by (dissipated in) an incremental mass (dm) contained in a volume element (dv) of a given density (). The equation description is asbelow:SAR is expressed in unit

25、s of Watts per kilogram (W/kg)SAR measurement can be related to the electrical field in the tissue byWhere: is the conductivity of the tissue, is the mass density of the tissue and E is the RMS electrical fieldstrength.3.2 SPEAG DASY SystemDASY system consists of high precision robot, probe alignmen

26、t sensor, phantom, robot controller, controlled measurement server and near-field probe. The robot includes six axes that can move to the precision position of the DASY5 software defined. The DASY software can define the area that is detected by the probe. The robot is connected to controlled box. C

27、ontrolled measurement server is connected to the controlled robot box. The DAE includes amplifier, signal multiplexing, AD converter, offset measurement and surface detection. It is connected to the Electro-optical coupler (ECO). The ECO performs the conversion form the optical into digital electric

28、 signal of theDAE and transfers data to the PC.Report Format Version 5.0.0 Report No. : SE140924C06CReference No.: 141126C03Page No.: 6 of 25Issued Date : Dec. 10, 2014CE SAR Test ReportFig-3.1 DASY System Setup3.2.1RobotThe DASY system uses the high precision robots from Stubli SA (France). For the

29、 6-axis controller system, the robot controller version (DASY5: CS8c) from Stubli is used. The Stubli robot series have many features that are important for our application: High precision (repeatability 0.035 mm) High reliability (industrial design) Jerk-free straight movements Low ELF interference

30、 (the closed metallic construction shields against motor control fields)Report Format Version 5.0.0 Report No. : SE140924C06CReference No.: 141126C03Page No.Issued Date: 7 of 25: Dec. 10, 2014Fig-3.2 DASY5CE SAR Test Report3.2.2ProbesThe SAR measurement is conducted with the dosimetric probe. The pr

31、obe is specially designed and calibrated foruse in liquid with high permittivity. The dosimetric probe has special calibration in liquid at different frequency.3.2.3Data Acquisition Electronics (DAE)Report Format Version 5.0.0 Report No. : SE140924C06CReference No.: 141126C03Page No.: 8 of 25Issued

32、Date : Dec. 10, 2014ModelDAE3, DAE4ConstructionSignal amplifier, multiplexer, A/D converter and control logic. Serial optical link for communication with DASY embedded system (fully remote controlled). Two step probe touch detector for mechanical surface detection and emergency robot stop.Measuremen

33、t Range-100 to +300 mV (16 bit resolution and two range settings: 4mV, 400mV)Input Offset Voltage 5V (with auto zero)Input Bias Current 50 fADimensions60 x 60 x 68 mmModelES3DV3ConstructionSymmetrical design with triangular core. Interleaved sensors. Built-in shielding against static charges. PEEK e

34、nclosure material (resistant to organic solvents, e.g., DGBE).Frequency10 MHz to 4 GHz Linearity: 0.2 dBDirectivity 0.2 dB in HSL (rotation around probe axis) 0.3 dB in tissue material (rotation normal to probe axis)Dynamic Range5 W/g to 100 mW/g Linearity: 0.2 dBDimensionsOverall length: 337 mm (Ti

35、p: 20 mm) Tip diameter: 3.9 mm (Body: 12 mm)Distance from probe tip to dipole centers: 2.0 mmModelEX3DV4ConstructionSymmetrical design with triangular core. Built-in shielding against static charges. PEEK enclosure material (resistant to organic solvents, e.g., DGBE).Frequency10 MHz to 6 GHz Lineari

36、ty: 0.2 dBDirectivity 0.3 dB in HSL (rotation around probe axis) 0.5 dB in tissue material (rotation normal to probe axis)Dynamic Range10 W/g to 100 mW/gLinearity: 0.2 dB (noise: typically 20 dBPower Capability 100 W (f 40 W (f 1GHz)CE SAR Test ReportTable-3.1 Targets of Tissue Simulating LiquidThe

37、following table gives the recipes for tissue simulating liquids.Table-3.2 Recipes of Tissue Simulating LiquidReport Format Version 5.0.0 Report No. : SE140924C06CReference No.: 141126C03Page No.: 11 of 25Issued Date : Dec. 10, 2014Tissue TypeBactericideDGBEHECNaClSucroseTriton X-100WaterDiethylene G

38、lycol Mono- hexyletherH7500.2-0.21.556.0-42.1-H8350.2-0.21.557.0-41.1-H9000.2-0.21.458.0-40.2-H1450-43.3-0.6-56.1-H1640-45.8-0.5-53.7-H1750-47.0-0.4-52.6-H1800-44.5-0.3-55.2-H1900-44.5-0.2-55.3-H2000-44.5-0.1-55.4-H2300-44.9-0.1-55.0-H2450-45.0-0.1-54.9-H2600-45.1-0.1-54.8-H3500-8.0-0.2-20.071.8-H5G

39、-17.265.517.3Frequency (MHz)Target PermittivityRange of5%Target ConductivityRange of5%75041.939.8 44.00.890.85 0.9383541.539.4 43.60.900.86 0.9590041.539.4 43.60.970.92 1.02145040.538.5 42.51.201.14 1.26164040.338.3 42.31.291.23 1.35175040.138.1 42.11.371.30 1.44180040.038.0 42.01.401.33 1.47190040.

40、038.0 42.01.401.33 1.47200040.038.0 42.01.401.33 1.47230039.537.5 41.51.671.59 1.75245039.237.2 41.21.801.71 1.89260039.037.1 41.01.961.86 2.06350037.936.0 39.82.912.76 3.06520036.034.2 37.84.664.43 4.89530035.934.1 37.74.764.52 5.00550035.633.8 37.44.964.71 5.21560035.533.7 37.35.074.82 5.32580035.

41、333.5 37.15.275.01 5.53CE SAR Test Report3.3 SAR System VerificationThe system check verifies that the system operates within its specifications. It is performed daily or before every SAR measurement. The system check uses normal SAR measurements in the flat section of the phantom with a matched dip

42、ole at a specified distance. The system verification setup is shown as below.The validation dipole is placed beneath the flat phantom with the specific spacer in place. The distance spacer is touch the phantom surface with a light pressure at the reference marking and be oriented parallel to the lon

43、g side of the phantom. The power meter PM1 measures the forward power at the location of the system check dipole connector. The signal generator is adjusted for the desired forward power (250 mW is used for 700 MHz to 3 GHz, 100 mW is used for 3.5 GHz to 6 GHz) at the dipole connector and the power meter PM2 is read at that level. Afterconnecting the cable to the dipole, the signal generator is readjusted for the same reading at power meter PM2.After system check testing, the SAR result will be normalize

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負責。
  • 6. 下載文件中如有侵權(quán)或不適當內(nèi)容,請與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

最新文檔

評論

0/150

提交評論