1、CapitaLand Retail Limited's Requirement 嘉德商用產(chǎn)業(yè)有限公司SNoSystem / Area系統(tǒng)/區(qū)域Mechanical and Electrical Installations附件五:精裝修標(biāo)準(zhǔn)之機(jī)電設(shè)施1Airconditioning system空調(diào)通風(fēng)系統(tǒng)Temperature設(shè)置溫度冬季:18oC - 20oC (除廣東、廣西、福建、海南、云南外 )Design for 18 - 20oC (winter except GuangDong, GuangXi,FuJian, HaiNan, YunNan)夏季:24oC - 26oC24

2、 -26oC (summer)2Relative Humidity相對(duì)濕度相對(duì)濕度 65%Relative humidity< 65%3Noise Criteria噪音控制室內(nèi)噪音(DBANoise Criteria (NC) level餐廳-55Restaurant/F&B -50美食閣/快餐店-55Food Court/Fast Food -50商場(chǎng)-55Retail Shop -50洗手間-55Toilet -50公共走廊 -55Lobby & Corridor 50停車(chē)場(chǎng)-70Carpark - 654Airlock room寒冷地區(qū)主入口增設(shè)門(mén)斗在以下地區(qū)的項(xiàng)目

3、的主入口位置,必須設(shè)雙道玻璃門(mén)。第一和第二道門(mén)不能同時(shí)打開(kāi),并達(dá)到節(jié)能防寒的效果:Provide airlock room with double doors at following region:a.溫和地區(qū)(日平均溫度低于 5oC的天數(shù)有0至90天)a. Temperate Region (Region with average temperature below5oC for not more than 90 days)b.夏熱冬冷的地區(qū)(日平均溫度低于 5oC的天數(shù)有0至90天)b. Region with average temperature below 5oC for not

4、morethan 90 daysC.寒冷地區(qū)(日平均溫度低于 5oC的天數(shù)有90至145天)c. Region with average temperature below 5oC for more than90 days to 145daysd.嚴(yán)冬地區(qū)(平均溫度低于5oC的天數(shù)超過(guò)145天)c. Region with average temperature below 5oC for more than145days第1道和第2道門(mén)的自動(dòng)感應(yīng)器不能同時(shí)啟動(dòng)。第 1道玻門(mén)和 第2道玻璃門(mén)開(kāi)啟位置應(yīng)錯(cuò)開(kāi)避免風(fēng)可以直接進(jìn)入。Double doors of airlock room shall

5、not activate simultaneously第1道玻璃門(mén)和第2道玻璃門(mén)的總寬度必須一致;Door width of the double door shall be the same室內(nèi)第1道玻璃門(mén)上方要有電熱風(fēng)幕機(jī)(寒冷、嚴(yán)寒)普通風(fēng) 幕(其它區(qū)域)Provide Air curtain with heating capability5ventilation system通風(fēng)系統(tǒng)地下車(chē)庫(kù)、變配電室、水泵房、制冷機(jī)房、鍋爐房、發(fā)電機(jī)房等設(shè)置機(jī)械通風(fēng)系統(tǒng)Provide mechanical ventilation system in underground car park, elec

6、trical room, pump room, chiller room, boiler room, generator room弱電間(弱電井除外)、衛(wèi)生間及垃圾房等設(shè)置機(jī)械排風(fēng)系 統(tǒng)Provide exhaust ventilator in the electrical room room (low voltage), toilets and bin center餐廳、快餐店、咖啡廳、美食閣、小吃店等廚房設(shè)置排風(fēng)及 送風(fēng)系統(tǒng),包括風(fēng)機(jī)(但不包括油煙處理)Provide mechanical ventilation system for restaurants, fast food, caf

7、 , food court and snack shop, including ventilation fans but excludes kitchen exhaust air treatment system衛(wèi)生間及垃圾房等設(shè)置機(jī)械排風(fēng)系統(tǒng)Provide Mechanical Ventilation system to Bin center andToilet洗手間15次換氣/小時(shí)Toilet -15 air change/hour地下車(chē)庫(kù)6次換氣/小時(shí)Basement car park 6 change/hour變配電室 至少8-15次換氣/小時(shí),必須參考設(shè)備發(fā)熱量核對(duì),若有需要可適當(dāng)增

8、加)Electrical room 8-15 change/hour (to consider heat ejection by equipment, add if necessary)制冷機(jī)房4-6次換氣/小時(shí)Chiller room 4-6 change/hour水泵房4-6次換氣/小時(shí)Pump room 4-6 change/hour6Kitchen Exhuast System廚房排煙系統(tǒng)小吃/咖啡廳/餐廳/快餐/美食閣(按商鋪?zhàn)赓U面積確定其 廚房排風(fēng)量):Kitchen -Based on following lease area to provide kitchen exhaust

9、 system:20< S m2 1000CMH20WS m2 1000CMH20< S< 40n2 3000CMH20WS< 40m2 3000CMH40 w S< 80n2 6000CMH40WS< 80m2 6000CMH80< S< 160n2 12000CMH80WS< 160m212000CMH160< S< 240n2 16000CMH160WS< 240m216000CMH240w S< 320n2 20000CMH240WS<320m2 20000CMH320< Sw 1000n2 25

10、000CMH320 < S<1000m2 25000CMH1000<S< 1200n2 60000CMH1000<S< 1200m2 60000CMHS> 1200n2 120000CMHS > 1200m2120000CMH建議如上,送風(fēng)在8090%的排風(fēng)量。Fresh air or replacement air shall design at 80 to 90 % of exhaust-air capacity7HVAC system空調(diào)系統(tǒng)Shopping Mall商場(chǎng)內(nèi)商場(chǎng)租戶區(qū)、辦公室、衛(wèi)生間(包括男、女、殘疾人衛(wèi)生間、嬰兒房)、一層

11、消防通道、客梯廳、自動(dòng)坡道、中庭、 商場(chǎng)公共區(qū)域及物業(yè)管理辦公室等均應(yīng)設(shè)置中央空調(diào)系統(tǒng)Central air-conditioning shall also be provided to the toilets, handicapped toilet, baby room, mall' s common corrtenants ' area, office area.物業(yè)管理辦公室應(yīng)采用風(fēng)機(jī)盤(pán)管或吊裝式空調(diào)機(jī)組加獨(dú)立 新風(fēng)系統(tǒng)。由于員工能在商場(chǎng)非營(yíng)業(yè)時(shí)間辦公,空調(diào)系統(tǒng)必 須是獨(dú)立式分體機(jī)系統(tǒng)。室外機(jī)應(yīng)設(shè)在屋面。如物業(yè)管理辦 公室在負(fù)一樓,室外機(jī)又無(wú)法達(dá)到美觀的情況下,室外機(jī)可

12、以設(shè)在負(fù)一樓All other tenants' return air louver shall be located in pulcommon area. The fan coil unit or hoisting type air handling unit shall be located in public common area美食閣或面積A 1000m2商鋪可采用一次回風(fēng)全空氣系統(tǒng) (必 須有雙方認(rèn)可)。衛(wèi)生間應(yīng)采用風(fēng)機(jī)盤(pán)管系統(tǒng)。除上述區(qū)域 外的其他區(qū)域應(yīng)采用吊裝式空調(diào)機(jī)組加獨(dú)立新風(fēng)系統(tǒng)Air-conditioning shall be hanging-type air h

13、andling unit or fan coil unit unless specified. Food court or restaurant exceeding 1000m2 can be floor-mounted air conditioning unit shall be placed in AHU room.每臺(tái)空調(diào)箱冷凍回水管上設(shè)置比例積分電動(dòng)閥。每臺(tái)風(fēng)機(jī)盤(pán) 管冷凍回水管上設(shè)置電動(dòng)二通閥.溫控方式采用就地控制。Provide proportional integral valve in each AHU chilled water return pipe. Provide two

14、 ways electronic valve in each FCU chilled water return pipe. Provide local temperature sensors8M&E Rooms機(jī)房空調(diào)系統(tǒng)電梯機(jī)房,變壓器室、高/低配電機(jī)房提供空調(diào)和排風(fēng)和新 風(fēng)系統(tǒng).在嚴(yán)寒及寒冷地區(qū),空調(diào)系統(tǒng)可免。lift motor room, transformer rooms, high/low tension room shall be installed with split unit system9Chiller空調(diào)冷水機(jī)空調(diào)冷水機(jī)組至少配置2臺(tái),冷水機(jī)組采用環(huán)保冷媒Pro

15、vide at least 2 sets of water cooled chiller and environmentally friendly10Chilled Water and Condenser Pumps冷凍及冷卻水泵冷凍及冷卻水泵應(yīng)各設(shè)置一臺(tái)備用泵One spare water pump is required for each chilled water pump and condenser water pump11Ductworks鳳管空調(diào)風(fēng)管采用鍍鋅鋼板制作加鋁箔貼面玻璃棉保溫(保護(hù) 層為鋁箔),或采用復(fù)合風(fēng)管Air conditioning duct shall be m

16、ade with galvanized steel plate with aluminum foiled glass12Insulation保溫材料空調(diào)冷凍水管、冷凝水管保溫材料采用橡塑閉孔發(fā)泡材料 或PEF聚乙烯材料。The insulating materials used in air-conditioning chilled water pipe, condenser water pipe shall be rubber and plastic closehole foam material13Heating System采暖系統(tǒng)除廣東、廣西、海南、福建、云南五省不提供采暖系統(tǒng) 夕卜,

17、所有商場(chǎng)均應(yīng)設(shè)置冷暖型中央空調(diào)系統(tǒng)Heating system shall be provided in all cities with the exception of those located in GuangDong, GuangXi, HaiNan, FuJian, YunNan有集中供暖管網(wǎng)的地區(qū),應(yīng)設(shè)熱交換站供暖Provide heat exchanger station in the district with heating supply network無(wú)集中供暖管網(wǎng)的地區(qū),應(yīng)設(shè)置常壓、負(fù)壓熱水鍋爐或其 它國(guó)家規(guī)范允許的供熱設(shè)備供暖Provide normal pressur

18、e and negative pressure hot water boiler or any other approved equipment by the code of practice in other countries in the district without heating supply network寒冷地區(qū)必須設(shè)冷暖分體空調(diào)包括消防控制中心Split unit system in cold areas shall complete with heating system eg. Fireman Control Center, etc空調(diào)系統(tǒng)冷/熱采用人工轉(zhuǎn)換,轉(zhuǎn)換閥門(mén)設(shè)

19、置于安全及易操 作處The manual cold/warm control and valve control shall be easy to use and installed at a safe place14CMO Computer Room電腦機(jī)房物業(yè)管理電腦機(jī)房設(shè)機(jī)械排風(fēng)系統(tǒng)加獨(dú)立式分體空調(diào),該 空調(diào)連接到發(fā)電機(jī)。當(dāng)停電發(fā)電機(jī)開(kāi)動(dòng)時(shí),空調(diào)必須自動(dòng)起 動(dòng)。The air-conditioning design intent of the server room in CMO is to use MV cum split unit system and connected to th

20、e emergency generator. The split unit must be able to auto start during emergency mode14aTenant Areas交房時(shí)應(yīng)具備的條件1.當(dāng)管道從商鋪?zhàn)赓U線中間穿越時(shí),在空間高度允許的條件 下,控制區(qū)域(租賃線以內(nèi)w 1.0m區(qū)域)必須預(yù)留550mm高 度作為防盜卷簾安裝的高度。1.Services install across at center of lease line shall not below4.35m. It is to cater for the installation of tenant

21、s' security roller shutter (550mm height)2.如果設(shè)計(jì)標(biāo)高在不允許的條件下,所有機(jī)電設(shè)施空調(diào)風(fēng)機(jī) 設(shè)備安裝建議/要求如下:2f the above is not achievable, following methods (Option 1) is preferable:a.空調(diào)機(jī)回風(fēng)口在店鋪外,離租賃線區(qū)域至少300mma. Return grille is outside of tenant areas by 300mmb.管道與空調(diào)通風(fēng)設(shè)施最宜在30%L1面設(shè)計(jì)區(qū)域,不會(huì)影 響防盜卷簾的安裝見(jiàn)建筑交樓標(biāo)準(zhǔn),示意圖(一);b. Referen

22、ce to Sketch 1, services shall install within <30% of tenant shop front3.當(dāng)無(wú)法滿足以上的條件下或符合空調(diào)系統(tǒng)第 7條相關(guān)要 求,空調(diào)設(shè)備應(yīng)設(shè)置在商鋪內(nèi),設(shè)備安裝見(jiàn)示意圖(二);3. If the above is not achievable, following methods (Option2) is preferable, see sketch 24.店鋪內(nèi)噴淋、煙感、出風(fēng)口等設(shè)施應(yīng)統(tǒng)一標(biāo)高并與公共吊 頂齊平,標(biāo)高施工誤差應(yīng)減小到最低3mm/2m4. Sprinklers head, smoke detect

23、ors, and air-conditioning outlets shall same with the corresponding ceiling height in common corridor5.控制區(qū)域(租賃線以內(nèi)w 1.0m區(qū)域)不應(yīng)有任何機(jī)電設(shè)備 出現(xiàn)如:噴淋頭、煙感等且噴淋頭距離 1.0m (即門(mén)頭內(nèi)側(cè)) 應(yīng)該滿足國(guó)家規(guī)范要求;5. No exposed services shall within 1000mm of lease line within tenant space6.租賃線外側(cè)300mn之內(nèi)不允許有任何設(shè)備如:燈具、自動(dòng) 噴淋系統(tǒng)、煙感、揚(yáng)聲器、回風(fēng)、出風(fēng)口等;

24、6. No exposed services at common corridor shall within300mm of tenant shop front7.風(fēng)機(jī)盤(pán)管的溫控器,應(yīng)設(shè)置在商鋪內(nèi)距離租賃線 1.0m1.5m處在天花下, 距天花標(biāo)高下返150mm位置處, 吊裝式空調(diào)機(jī)組的溫控器應(yīng)設(shè)置在設(shè)備的面板上,立柜式空 調(diào)機(jī)組的溫控器設(shè)置在機(jī)房?jī)?nèi),由商場(chǎng)統(tǒng)一控制:7. Air-conditioning sensor shall install under ceiling level by 150mm, around 1m to 1.5m from lease line. Temperatu

25、re controller for FCU and AHU, shall install at equipment. On-off controls shall be centralized at every floor or in fireman control room.15FIRE PROTECTIONSYSTEM消防系統(tǒng)Spri nklers System噴淋系統(tǒng)根據(jù)商鋪布置,商鋪墻斷形式及平面圖,公共區(qū)域、走廊、 洗手間以及每個(gè)新租賃單位有吊頂部位,按照消防規(guī)范要求 設(shè)噴淋器吊頂夾層高800mm并有易燃物的吊頂內(nèi)應(yīng)設(shè)噴淋 (除洗手間外)Based on the layout of t

26、he shop units and tenancy walls, provide 2nd layer of sprinkler point for all common area, corridor, toilets, and tenants with false ceiling in compliance with code of practice. For false ceiling above 800mm and consists of combustible material, concealed sprinklers shall also be provided (except to

27、ilets)在消防局同意下,在竣工驗(yàn)收前商鋪內(nèi)均按假設(shè)沒(méi)有吊頂考 慮設(shè)置下噴噴頭,噴頭標(biāo)高根據(jù)臨近公共區(qū)域吊頂標(biāo)高一 致。Upon mutual agreement with Fire Department, sprinklers within tenant units shall install downwards. Height of downwards sprinklers head shall same as ceiling height at corridor16Fire Zoning防火間隔在竣工驗(yàn)收前,根據(jù)最后的用戶設(shè)計(jì)重新對(duì)防火分區(qū)進(jìn)行布局設(shè)計(jì)(以當(dāng)?shù)卣臑闇?zhǔn))To re-

28、zone fire compartmentation based on latest tenants layout, subjected to approval of local authority.17ExtinguisherFire hosereel system消防栓系統(tǒng)滅火器盡量將消火栓布置在公共區(qū)域,消除不必要的字體,由于美觀的原因,要凹進(jìn)墻體里面To ensure locations of hosereel are along common area and remove unnecessary wordings from the hosereel. Must be recesse

29、d onto the wall for aesthetic reason租戶商鋪內(nèi)應(yīng)避免供任何公共區(qū)域使用的消火栓和滅火器及非租戶使用的機(jī)電控制和監(jiān)督設(shè)備N(xiāo)o hose reel within tenant space, unless required by code必須提供整個(gè)商場(chǎng)內(nèi)滅火器Provide extinguisher within the shopping mall提供氣體滅火系統(tǒng)在物業(yè)電腦機(jī)房、不需要噴淋頭Provide gas suppression system at CMO computer room. NoSprinklers消火栓和滅火器在有裝飾材料位置處不必訂購(gòu)?fù)忾T(mén)

30、,消火栓和滅火器需設(shè)暗門(mén),材料與裝飾完成面一致Hose reel and extinguisher shall conceal behind a finished door, using same material as ID material18Exit Signage安全出口燈箱安全出口燈箱按照最新租區(qū)分布圖來(lái)遷移裝在吊頂下Exit sign to relocate to suit latest tenants ' unit layout suspended from false ceilingTenant Areas交房時(shí)應(yīng)具備的條件店鋪內(nèi)噴淋、煙感、出風(fēng)口等設(shè)施應(yīng)統(tǒng)一標(biāo)高并與公

31、共吊頂齊平,標(biāo)高施工誤差應(yīng)減小到最低 <3mm/2mSprinklers head, smoke detectors, and air-conditioning outlets shall same with the corresponding ceiling height in common corridor控制區(qū)域(租賃線以內(nèi)w 1.0m區(qū)域)不應(yīng)有設(shè)施、風(fēng)口、噴 淋頭、煙感等且噴淋頭距離1.0m (即門(mén)頭內(nèi)側(cè))應(yīng)該滿足國(guó) 家規(guī)范要求;No exposed services shall within 1000mm of lease line within tenant space租賃

32、線外側(cè)300mr之內(nèi)不允許有設(shè)施、燈具、自動(dòng)噴淋系統(tǒng)、 煙感、揚(yáng)聲器、回風(fēng)、出風(fēng)口等;No exposed services at common corridor shall within 300mm of tenant shop front19Cold Water DistributionSystem給水系統(tǒng)Water meter and pipe size給水表和管經(jīng)給水管道布置到所有商鋪包括餐飲提供水點(diǎn),并在吊頂內(nèi)安裝普通水表Water supply pipe shall be catered to all tenants includingF&B outlets with wa

33、ter meter installed above ceiling and the requirement are:-美食廣場(chǎng)80mr水表、100mr給水接口Food court water meter at 80mm with water pipe at 100mm餐廳/快餐/咖啡廳/美容院40mn水表、50mr給水接口Restaurant/fast food/caf /beauty spa/fitness water meter at40mm with water pipe at 50mm其他商店20mn水表、25mr給水接口The rest of retails water meter

34、at 20mm with water pipe at25mm20CMO Pa ntry物業(yè)辦公室茶水區(qū)提供給水點(diǎn)Provide 1 water point21Water point forMaintenance給水點(diǎn)供保修提供給水點(diǎn)在垃圾房、停車(chē)庫(kù)和屋面方便保潔Provide water point at strategic locations in the bin centre, car park and roof etc for general cleaning purposes給水點(diǎn)應(yīng)安裝在,遠(yuǎn)離停車(chē)位,不阻礙停車(chē)柱體一側(cè),以免 刮壞車(chē)體并應(yīng)上鎖。Location of the wate

35、r tap shall not hinder parking, and will not damage the car during parking. Water tap shall complete with cap-lock.22Tenant Areas交房時(shí)應(yīng)具備的條件中島小吃餐飲部分地漏不應(yīng)設(shè)在靠近走廊通道位置的區(qū)域, 最好設(shè)在隔墻角落位置,并應(yīng)與電源線集中布置,不應(yīng)分散 布置(因?yàn)橥ǔN房地漏與電源在設(shè)計(jì)時(shí)就統(tǒng)一考慮,避免 明線出現(xiàn)的問(wèn)題);鋼套管的電源線也最好靠近隔墻位置Floor trap at open-concept tenant unit shall install awa

36、y from lease lineLandscape Water Point給水點(diǎn)供綠化提供給水點(diǎn)在室外給予清理和綠化的要求Provide water point at strategic locations outdoor for general cleaning and landscape used23Sanitary System排水系統(tǒng)Grease Trap隔油池給污水系統(tǒng)連接所有商鋪包括餐飲提供水點(diǎn)和地漏并通往 隔油池。隔油池的容數(shù)量按整個(gè)項(xiàng)目排水量的50%考慮Provide water point and floor trap to all retail shops includi

37、ng F&B outlets connected to grease traps. However, the numbers of grease traps to size to 50% of the discharge from the entire development24Floor Traps地漏餐飲業(yè)租戶排水總管必須是150mm地漏100mr設(shè)計(jì)時(shí)排水接 通。其他商鋪排水總管至少是DN150地漏為DN75設(shè)計(jì)時(shí)排水接 通,但在地漏上方設(shè)鐵板封閉Discharge stack and main discharge pipe diamete for F&B and ret

38、ail is 150mm. Floor trap diameter shall be 100mm for F&B, and the rest 75mm diameter floor trap. All pipes shall be connected. Provide metal plate or capping for all unused floor traps (retail).地漏數(shù)量(按租賃面積,S)為:Number of floor traps (based on area) are:S < 50 m 2 1 個(gè)S < 50 m2 1no.50< S<

39、; 200n2 2 個(gè)50<S<200m2 2no.200< S< 300n2 3200<S<300m2 3no.每100n2加1個(gè)Every100m2 add 1no如地下一層是人防區(qū)域,在相關(guān)一樓的商鋪地漏數(shù)量(按租賃面積,S)為:If the basement 1 is civil defense shelter, the number of floor traps at the corresponding areas at level 1 are:50< S m2 2 個(gè)50< S m22no.50< S< 200n2 3 個(gè)

40、50<S<200m2 3no.200< S< 300n2 4 個(gè)200<S<300m2 4no.每100n2加1個(gè)Every100m2 add 1no商場(chǎng)餐飲類排水管道有結(jié)露可能,影響W喊其他區(qū)域的,應(yīng)作防結(jié)露保溫Provide insulation to all sanitary pipes serving F&B outlets include those serving Wal-Mart.所有同一個(gè)商鋪里的地漏距離必須相距3-5米。地漏位置應(yīng)設(shè)在商鋪后區(qū),不應(yīng)靠近走廊通道Spacing between floor traps within a

41、tenant leasable area shall be 3 to 5 meters apart. Floor traps shall away from lease line25Carpark Drainage停車(chē)庫(kù)提供排水點(diǎn)在停車(chē)庫(kù),方便車(chē)庫(kù)保潔Provide scrubber drain with floor trap at strategic locations within the carpark for general cleaning purposes.26CMO Pa ntry物業(yè)辦公室茶水區(qū)提供1個(gè)地漏在CM(的茶水間, 位置在洗手盆下Provide 1 Floor tra

42、p at CMO pantry, under the sink27Bin Center垃圾房提供排水點(diǎn)在垃圾房,地漏為 DN100方便保潔Provide floor trap at strategic locations in the bin centre for general cleaning purposes28Material給排水管材室外消防生活合用給水管:承插式球墨鑄鐵給水管或同類產(chǎn) 品The outdoor fire service and main water pipe : cast iron pipe室內(nèi)生活給水管:給水干管和立管用鋼塑給水管或同類產(chǎn)品,管徑W DN5(給水支

43、管用PPRfe活給水管或同類產(chǎn)品或同 類產(chǎn)品Indoor main water pipe (inlet): Main pipe and vertical pipe shall be steel/plastic composite pipe or equivalent, the pipe diameter shall not be more than 50mm and the branch-pipe shall be PPR water pipe or equivalent室內(nèi)消火栓管和噴淋管:熱鍍鋅鋼管Water pipe of indoor fire hydrant and sprinkle

44、rs : Galvanized steel pipe雨水管:UPV(排水管或排水鑄鐵管Storm water pipe: UPVC pipe or cast iron室內(nèi)污水管:衛(wèi)生間排水管用 UPV畠乍水管,商場(chǎng)排水管采用離心式排水鑄鐵管,立管和干管從室內(nèi)到室外第一個(gè)檢查井用離心式鑄鐵排水管Indoor sewer: The disposal pipe of washroom shall be UPVC pipe, the disposal pipe of centre shall be centrifugal cast iron pipe, the vertical pipe and ma

45、in pipe (from indoor to the first inspection pit at outdoor) shall be centrifugal室內(nèi)冷凝水管:UPV排水管Indoor condensed water pipe: UPVC室外埋地雨水管、污水管:The underground storm water pipe (outdoor), shall be reinforced concrete pipe埋地雨水管采用鋼筋混凝土管,UPV(雙壁波紋管或同類產(chǎn) 品,埋地污水管均采用UPV(雙壁波紋管或同類產(chǎn)品or UPVC double walled corrugated

46、 pipe or equivalent. The sewage (outdoor) shall be UPVC double walled corrugated pipe or equivalent室內(nèi)壓力排水管:熱鍍鋅鋼管Indoor pressurized water disposal pipe: galvanizedGas Distribution System天燃?xì)庀到y(tǒng)29Gas Meters / Pressure valve表箱和調(diào)壓箱需提供天然氣點(diǎn)到租鋪里的閥門(mén)和接口。不包括燃?xì)夤臼?工完和開(kāi)通燃?xì)庵蟮母牟糠帧rovide gas distribution for tap-

47、off within tenant space. The works does not include any gas works after the gas installations is completed and with gas charged-in.天然氣的戶外主控制配箱、調(diào)壓箱必須隱蓋包裝。這是為了 安全和美觀理由。但必須得到燃?xì)夤菊J(rèn)可The main gas incoming control panel has to be screen off for security and aesthetic reasons. However, this has to be cleare

48、d by the gas authority company30Gas Piping Installation燃?xì)夤艿拦矃^(qū)域的燃?xì)獾陌惭b底標(biāo)高為公共區(qū)天花吊頂標(biāo)高上返 100mm以預(yù)留輕鋼龍骨高度;租戶餐飲區(qū)燃?xì)饪偪刂魄蜷y 安裝高度為3.5m以上或距公共區(qū)天花吊頂標(biāo)高下 250mm見(jiàn) 示意圖。但必須得到燃?xì)夤驹S可,最好套管不是鋼。Gas pipes shall install within ceiling. Gas connection point shall install at maximum 250mm below ceiling, or at 3.5m height or high

49、er. Box-up shall as far as possible, should not use metal, subject to approval of the gas department.公共區(qū)域的燃?xì)夥佬孤┨坠艿陌惭b底標(biāo)高為公共區(qū)天花吊 頂標(biāo)高上返100mm以預(yù)留輕鋼龍骨高度If there is box-up for gas pipes, it shall be at least 100mm higher from corridor ceiling height31Exposed Pipes明管在外裝的明管必須漆上和外裝的顏色,但必須得到燃?xì)夤?許可The natural

50、gas capacity for the eatery are as follows:32Gas Consumption天燃?xì)庥昧啃〕缘?餐廳/快餐/美食閣(按商鋪?zhàn)赓U面積確定其廚房排 風(fēng)量):The natural gas capacity for the eatery are as follows:S< 40n2 5CMHS < 40m25CMH40 w S< 160n2 15CMH40WS< 160m215CMH160 w S< 240n2 20CMH160WS<240m220CMH240w S< 320n2 25CMH240WS<320m

51、225CMH320w S< 400n2 30CMH320WS<400m230CMH400w S< 1000n2 0.08m3/h?n2h400WS<1000n2 0.08口3/?口2S> 1000n2 120CMHS>1000m2 120CMH天燃?xì)夤艿辣仨毥又辽啼亙?nèi),裝有閥門(mén)。The gas pipe 宙all be connected to within the tenant' steminate with gate valve整個(gè)項(xiàng)目燃?xì)饬繛?0%總用量考慮Total gas consunption is 70% of total denand

52、提供每租鋪一個(gè)燃?xì)馓筋^Provide 1 nunber of gas detector in every F&B tenant33ELECTRICALINSTALLTION電氣系統(tǒng)Electrical Provision (Eatery)用電量(餐飲)電力安裝建議使用照明電力(W/平方米),按130VA/平米考慮設(shè)計(jì),含空調(diào)負(fù)荷,按以下:餐廳與快餐(按商鋪?zhàn)赓U面積 S, 400 W/m2):Proposed Lighting & Power sq rn) and is based on 130VA/sqn inclusive of air-conditioning load.

53、Restaurant/FastFood/power provision as follows (400 W/n2):S< 20n2 16AS<20m216A20w S< 25n2 20A20WS< 25n2 20A25w S< 36n2 25A25WS< 36n2 25A36w S< 46n2 32A36WS< 46n2 32A46w S< 55n2 40A46WS< 55n2 40A55w S< 90n2 63A55WS< 90口2 63A90w S< 145n2 100A90WS< 145n2100A145

54、 w S< 235n2 160A145WS<235n2160A235w S< 290n2 200A235WS<290n2200A290w S< 365n2 250A290WS<365n2250A365w S< 440n2 300A365WS<440n2300A440w S< 585n2 400A440WS<585n2400A585w S< 735n2 500A585WS<735n2500A735w S< 925n2 630A735WS<925n2630A925w S< 1176n2 800A925WS&l

55、t;1176n2 800A以上全用三相電氣為標(biāo)準(zhǔn)The above is based on 3-phase power supply34Electrical Provision (Shop)用電量(商鋪)商鋪(按商鋪?zhàn)赓U面積 S, 55 W/m2,380V):Shop / Optical / Bookstore / Photo Shop (S, 55 W/n2):S<175r2 16AS<175m216A175w S< 220n2 20A175WS<220n220A220w S< 277n2 25A220WS<277n225A277w S< 355n2

56、 32A277WS<355n232A355w S< 435n2 40A355WS<435n240A435w S< 700n2 63A435WS<700n263A700w S< 885n2 80A700WS<885n280A885w S< 1110n2 100A885WS<1110n2 100A35Others其它業(yè)態(tài)其它業(yè)態(tài)的商鋪,可按以下設(shè)計(jì)(380V):Other business type (380V):美容院/健身院/美食廣場(chǎng)0.59 A/m2,或350 W/m2Spa / Fitness / Food court 0.59 A/m

57、2 or 350W/m2電器專賣(mài)店/咖啡廳/茶館100 W/m2Home appliance / caf / tea 100 W/m2百貨商場(chǎng)/商店0.09 A/m2 或55 W/m2Department stores / shop 0.09 A/m2 or 55W/m2以上全用三相電氣為標(biāo)準(zhǔn)The above is based on 3-phase power36illumination照明完成公共區(qū)域的照明,室外照明及園林照明。照明指標(biāo)提議:Complete lighting for the common areas, including external and landscape area. Illumination level proposed as follows:-大廳-300 luxLobbies - 300 lux-走廊-350 luxCirculation Path - 350 lux-地下停車(chē)場(chǎng)-200 luxBasement Car park - 200 lux-車(chē)道-200 luxDriveway & Ramp - 200 lux-洗手間-300 lu

溫馨提示

  • 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。

最新文檔

評(píng)論

0/150

提交評(píng)論