1、標(biāo)題:計量玻璃量器校準操作規(guī)程1.0目的:保證計量玻璃量器的有效使用,確保產(chǎn)品檢測過程的質(zhì)量。 2.0適用范圍;本公司常用玻璃量器(見表1)。刻度吸管1ml2ml5ml10ml15ml25 ml量筒/量杯/具塞量筒10ml25ml50ml250ml1000ml容量瓶10ml25ml50ml100ml250ml500ml1000ml單標(biāo)線移液管1ml5ml10ml20ml25ml50ml酸式/堿式滴定管10ml25ml50ml3.0校準依據(jù): 3.1 JJG196-2006常用玻璃量器檢定規(guī)程3.2 JJF1059-1999測量不確定度評定與表示4.0職責(zé): 4.1品管部計量管理人員負責(zé)計量儀器
2、的校準工作。 4.2實驗室配合計量管理人員進行校準工作。 5.0校準方法: 5.1校準項目分度吸量管 表 2標(biāo)識總?cè)萘縨l125101525方法分度值0.010.020.050.10.10.2外觀符合要求目視容量允差ml0.0080.0120.0250.050.050.10電子天平水流出時間4-104-12 6-14 7-177-1711-21秒表分度線寬度mm0.3放大鏡量筒/量杯/具塞量筒 表3標(biāo)識總?cè)萘縨l1025502501000方法分度值外觀符合要求目視容量允差ml0.200.500.502.010電子天平分度線寬度mm0.30.40.5放大鏡容量瓶 表4標(biāo)識總?cè)萘縨l1025501
3、002505001000方法外觀符合要求目視密合性無漏水現(xiàn)象手動容量允差ml0.0200.030.050.100.150.250.40電子天平分度線寬度mm0.4放大鏡單標(biāo)線移液管 表5標(biāo)識總?cè)萘縨l1510202550方法外觀符合要求目視容量允差ml0.0070.0150.0200.0300.0300.05電子天平水流出時間7-1215-2520-3025-3525-3530-40秒表分度線寬度mm0.4放大鏡酸式/堿式滴定管 表6標(biāo)識總?cè)萘縨l102550方法分度值0.050.10.1外觀符合要求目視容量允差ml0.0250.040.05電子天平水流出時間30-4545-7060-90秒表
4、等待時間30秒秒表分度線寬度mm0.3放大鏡5.2校準條件與設(shè)備: 5.2.1溫度:校準環(huán)境溫度 251,室內(nèi)溫度變化不超過1/h,水溫與室溫之差不超過2。 5.2.2校準所用介質(zhì):蒸餾水.5.2.3所用設(shè)備: 儀器名稱測量范圍技術(shù)要求備注電子天平21g分度值:0.01mg電子天平210g分度值:0.1mg精密溫度計1030分度值:0.1秒表060S分辨率:0.1S附件倍刻度放大鏡/具塞稱量瓶5.3校準過程: 外觀要求: a.量器應(yīng)具有廠名或商標(biāo),標(biāo)準溫度,用法標(biāo)記,標(biāo)稱總?cè)萘颗c單位,準確度等標(biāo)志。 b.量器無影響計量讀數(shù)的缺陷,包括集密的氣線,破氣線,擦傷,鐵屑和明顯的直棱線。c.分度線與量
5、的數(shù)值應(yīng)清晰、完整、耐久,相鄰兩分度線的寬度和分度值見表2表6。 d.非標(biāo)準的口與塞,活塞芯和外套,必須用相同的配合號碼。無塞滴定管的流液口與管下部也應(yīng)標(biāo)有同號。結(jié)構(gòu):a.玻璃量器的口應(yīng)與玻璃量器軸線相垂直,口邊要平整光滑,不得有粗糙處及未經(jīng)熔光的缺口。b.滴定管和吸量管的流液口,應(yīng)是逐漸地向管口縮小,流液口必須磨平倒角或熔光,口部不應(yīng)突然縮小,內(nèi)孔不應(yīng)偏斜。c.量筒、量杯的倒液嘴應(yīng)能使量筒、量杯內(nèi)液體呈細流狀倒出而不外溢。當(dāng)分度表面對觀察者時,倒液嘴的位置,量筒的嘴位于左側(cè);250ml以下的量杯(包括250ml)位于右側(cè);500ml以上的量杯位于左側(cè)。d. 量筒、量杯和量瓶放置在平臺上時,不
6、應(yīng)搖動??樟勘?、空量筒(不帶塞)和大于25ml(包括25ml)的空量瓶(不帶塞)放置在與水平面15的斜面上時,不應(yīng)跌倒,小于25ml的空量瓶(不帶塞),放置在與水平面10的斜面上時,不應(yīng)跌倒.密合性:a.滴定管玻璃活塞的密合性要求:將不涂油脂的活塞芯擦干凈后用水濕潤,插入活塞套內(nèi),滴定管應(yīng)垂直地夾在檢定架上,然后充水至最高標(biāo)線時,活塞在關(guān)閉情況下停留20min(塑料活塞靜置50min)后,滲漏量應(yīng)不大于最小分度值。b.座式滴定管和夾式滴定管,將水充至最高標(biāo)線,去掉注液管活塞以上的水,垂直靜置20min后,兩只活塞滲漏量應(yīng)不大于最小分度值。c.具塞量筒與量瓶:將玻璃塞擦干,不涂凡士林油脂,將水裝
7、至最高標(biāo)線,蓋緊后用手壓住塞子,顛倒 10次,每次顛倒時,在倒置狀態(tài)下停留 10s,結(jié)束后用干濾紙擦拭瓶口與玻璃瓶塞四周,不應(yīng)有水滲出。 流出時間:.1 滴定管a.將滴定管垂直夾在檢定架上,活塞芯涂上一層薄而均勻的油脂,不應(yīng)有水滲出。b.充水于最高標(biāo)線,流液口不應(yīng)接觸接水器壁。c.將活塞完全開啟并計時(對于無活塞滴定管應(yīng)用力擠壓玻璃小球),使水充分地從流液口流出,直到液面降至最低標(biāo)線為止的流出時間應(yīng)符合表6的規(guī)定。.2 分度吸量管和單標(biāo)線吸量管a.注水至最高標(biāo)線以上約5mm,然后將液面調(diào)至最高標(biāo)線處。b.將吸量管垂直放置,并將流液口輕靠接水器壁,此時接水器傾斜約30,在保持不動的情況下流出并計
8、時。以流至口端不流時為止,其流出時間應(yīng)符合表2和表5中的規(guī)定。 容量示值:容量檢定前須對量器進行清洗,清洗方法為:用重鉻酸鉀的飽和溶液和濃硫酸的混合液(調(diào)配比例為1:1)或20%發(fā)煙硫酸進行清洗。然后用水沖凈,器壁上不應(yīng)有掛水沾污現(xiàn)象,使液面與器壁接觸處形成正常彎月面。清洗干凈的被檢量器須在檢定前4小時放入實驗室內(nèi)。.1 衡量法a.取一只容量大于被檢玻璃量器的潔凈有蓋稱量杯,稱得空杯質(zhì)量。b.將被檢玻璃量器內(nèi)的純水放入稱量杯后,稱得純水的質(zhì)量。c.調(diào)整被檢玻璃量器液面的同時,應(yīng)觀察測量溫筒內(nèi)的水溫,讀數(shù)應(yīng)準確到0.1.d.玻璃量器在標(biāo)準溫度20時的實際容量下式計算:.(1)式中:V20標(biāo)準溫度
9、20時的被檢玻璃量器的實際容量,ml;B砝碼密度,取8.00 g/cm3;A測定時實驗室內(nèi)的空氣密度,取0.0012g/cm3;W蒸餾水t時的密度,g/cm3。被檢玻璃量器的體脹系數(shù),-1;t檢定時蒸餾水的溫度,;m被檢玻璃量器內(nèi)所能容納水的表觀質(zhì)量,g??蓪ⅲ?)式簡化為:V20=mK(t).(2)其中:K(t)值列于表7中,根據(jù)測定的質(zhì)量值(m)和測定水溫所對應(yīng)的K(t)值,即可由式(2)求出被檢玻璃量器在20時的實際容量。表7 1.(鈉鈣玻璃體脹系數(shù):25*10-6-1,空氣密度:0.0012g/cm3)水溫t/0.00.10.20.30.40.50.60.70.80.9151.0020
10、81.002091.002101.002111.002131.002141.002151.002171.002181.00219161.002211.002221.002231.002251.002261.002281.002291.002301.002321.00233171.002351.002361.002381.002391.002411.002421.002441.002461.002471.00249181.002511.002521.002541.002551.002571.002581.002601.002621.002631.00265191.002671.002681.00
11、2701.002721.002741.002761.002771.002791.002811.00283201.002851.002871.002891.002911.002921.002941.002961.002981.003001.00302211.003041.003061.003081.003101.003121.003141.003151.003171.003191.00321221.003231.003251.003271.003291.003311.003331.003351.003371.003391.00341231.003441.003461.003481.003501.
12、003521.003541.003561.003591.003611.00363241.003661.003681.003701.003721.003741.003761.003791.003181.003831.00386251.003891.003911.003931.003951.003971.001001.004021.004041.004071.004092.(硼硅玻璃體脹系數(shù):10*10-6-1,空氣密度:0.0012g/cm3)水溫t/0.00.10.20.30.40.50.60.70.80.9151.002001.002011.002031.002041.002061.0020
13、71.002091.002101.002121.00213161.002151.002161.002181.002191.002211.002221.002241.002251.002271.00229171.002301.002321.002341.002351.002371.002391.002401.002421.002441.00246181.002471.002491.002511.002531.002541.002561.002581.002601.002621.00264191.002661.002671.002691.002711.002731.002751.002771.00
14、2791.002811.00283201.002851.002861.002881.002901.002921.002941.002961.002981.003001.00303211.003051.003071.003091.003111.003131.003151.003171.003191.003221.00324221.003271.003291.003311.003331.003351.003371.003391.003411.003431.00346231.003491.003511.003531.003551.003571.003591.003621.003641.003661.
15、00369241.003721.003741.003761.003781.003811.003831.003861.003881.003911.00394251.003971.003991.004011.004031.004051.001081.004101.004131.004161.00419.2凡使用需要實際值的檢定,其檢定次數(shù)至少2次,2次檢定數(shù)據(jù)的差值不超過被檢玻璃容量允差的1/4,并取2次的平均值。.3 容量比較法a.將被檢玻璃量器用配好的洗液進行清洗,然后用水沖洗,使標(biāo)準玻璃量器內(nèi)無積水現(xiàn)象,液面與器壁能形成正常的彎月面。b.將被檢玻璃量器和標(biāo)準玻璃量器安裝到容量比較法檢定裝置上
16、。c.排除檢定裝置內(nèi)的空氣,檢查所有活塞是否漏水,調(diào)整標(biāo)準玻璃量器的流出時間和零位,使檢定裝置處于正常工作狀態(tài)。d.將被檢玻璃量器的容量和標(biāo)準玻璃量器的容量進行比較,觀察被檢玻璃量器的容量示值是否在允差范圍內(nèi)。.4檢定點的選擇a.滴定管:10ml半容量和總?cè)萘績牲c; 25ml(0-5)ml、(0-10)ml、(0-15)ml、(0-20)ml、(0-25)ml五點;50ml(0-10)ml、(0-20)ml、(0-30)ml、(0-40)ml、(0-50)ml五點;b.分度吸量管:0.5ml以上的檢定點總?cè)萘康?/10,若無總?cè)萘康?/10分度線,則檢2/10點(自流液口起);半容量(半容量流
17、液口);總?cè)萘俊.量筒、量杯:總?cè)萘康?/10,若無總?cè)萘康?/10分度線,則檢2/10點(自底部起);半容量(半容量流液口);總?cè)萘?。d.容量瓶、單標(biāo)線移液管:總?cè)萘俊?.3.6分度線寬度:使用 1X10倍刻度放大鏡,觀察分度線寬度,分度線最大寬度應(yīng)符合表2表6中的要求。5.4常用玻璃量器容量檢定操作步驟滴定管(衡量法)a.將清洗干凈的被檢滴定管垂直穩(wěn)固地安裝到檢定架上,充水至最高標(biāo)線以上約5mm處。b.緩慢地將液面調(diào)整到零位,同時排出流液口中的空氣,移去流液口的最后一滴水珠。c.取一只容量大于被檢滴定管容量的帶蓋的稱量杯,稱得空杯質(zhì)量。d.完全開啟活塞(對于無塞滴定管還需用力擠壓玻璃小球
18、),使水充分地從流液口流出。e.當(dāng)液面降至被檢分度線以上約5mm處時,等待30s,然后10s內(nèi)將液面調(diào)至被檢分度線上,隨即用稱量杯,移去流液口的最后一滴水珠。f.將被檢滴定管內(nèi)的純水放入稱量杯后,稱得純水質(zhì)量(m)。g.在調(diào)整被檢滴定管液面的同時,應(yīng)觀察測量溫筒內(nèi)的水溫,度數(shù)應(yīng)準確到0.1。h.按.1衡量法計算被檢定滴定管在標(biāo)準溫度20時的實際容量。i.對滴定管除計算各檢定點容量誤差外,還應(yīng)計算任意兩檢定點之間的最大誤差。分度吸量管和單標(biāo)線移液管(衡量法)a.將清洗干凈的吸量管垂直放置,充水至最高標(biāo)線以上約5mm處,擦去吸量管流液口外面的水。b.緩慢地將液面調(diào)整到被檢分度線上,移去流液口的最后一滴水珠。c.取一只容量大于被檢吸量管容量的帶蓋的稱量杯,稱得空杯質(zhì)量。d.將流液口于稱量杯內(nèi)壁接觸,稱量杯傾斜30,使水充分地流入稱量杯中。對于流出式吸量管,當(dāng)水流至流液口口端不流時,近似等待3秒鐘,隨即用稱量杯移去流液口的最后一滴水珠(口端保留殘留液)。對于吹出式吸量管,當(dāng)水流至流液口口端不流出時,隨即將流液口
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 培訓(xùn)員工財務(wù)管理制度
- 學(xué)校自主采購管理制度
- 北碚公司員工管理制度
- 售后維修員工管理制度
- 工程建設(shè)監(jiān)理管理制度
- 公司貨品集中管理制度
- 內(nèi)部控制招標(biāo)管理制度
- 公司報修報損管理制度
- 工程職業(yè)健康管理制度
- 工廠介質(zhì)使用管理制度
- 紋身學(xué)徒合同協(xié)議書范本
- 2025年大數(shù)據(jù)與商業(yè)分析專業(yè)畢業(yè)考試試題及答案
- 2024年江蘇省如皋市事業(yè)單位公開招聘教師崗考試題帶答案分析
- 中班語言學(xué)習(xí)活動優(yōu)化計劃
- 2025年下半年華電金沙江上游水電開發(fā)限公司校園招聘易考易錯模擬試題(共500題)試卷后附參考答案
- 計算機網(wǎng)絡(luò)安全基礎(chǔ)試題及答案
- 動漫產(chǎn)業(yè)協(xié)同創(chuàng)新與產(chǎn)業(yè)鏈協(xié)同效應(yīng)動態(tài)變化趨勢及對策建議報告
- 2025-2030年中國影視基地行業(yè)深度發(fā)展研究與“十四五”企業(yè)投資戰(zhàn)略規(guī)劃報告
- 兒童發(fā)展問題的咨詢與輔導(dǎo)-案例1-5-國開-參考資料
- 安全生產(chǎn)法律法規(guī)匯編(2025版)
- 煙氣凈化輸送風(fēng)管防腐分項工程質(zhì)量檢驗評定表
評論
0/150
提交評論