版權(quán)說(shuō)明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡(jiǎn)介
1、-PAGE . z.英文原文:Rehabilitation of rectangular simply supported RC beams with shear deficiencies using CFRP positesAhmed Khalifa a,* , Antonio Nanni ba Department of Structural Engineering, University of Ale*andria, Ale*andria 21544, EgyptbDepartment of Civil Engineering, University of Missouri at Rol
2、la, Rolla, MO 65409, USAReceived 28 April 1999; received in revised form 30 October 2001; accepted 10 January 2002AbstractThe present study e*amines the shear performance and modes of failure of rectangular simply supported reinforced concrete(RC) beams designed with shear deficiencies. These member
3、s were strengthened with e*ternally bonded carbon fiber reinforced polymer (CFRP) sheets and evaluated in the laboratory. The e*perimental program consisted of twelve full-scale RC beams tested to fail in shear. The variables investigated within this programincluded steel stirrups, and the shear spa
4、n-to-effective depth ratio, as well as amount and distribution of CFRP. The e*perimental results indicated that the contribution of e*ternally bonded CFRP to the shear capacity was significant. The shear capacity was also shown to be dependent upon the variables investigated. Test results were used
5、to validate a shear design approach, which showed conservative and acceptable predictions. eq oac(,C) 2002 Elsevier Science Ltd. All rights reserved.Keywords: Rehabilitation; Shear; Carbon fiber reinforced polymer1. IntroductionFiber reinforced polymer (FRP) posite systems, posed of fibers embedded
6、in a polymeric matri*, can be used for shear strengthening of reinforced con-crete (RC) members 17. Many e*isting RC beams are deficient and in need of strengthening. The shear failure of an RC beam is clearly different from its fle*ural failure. In shear, the beam fails suddenly without sufficient
7、warning and diagonal shear cracks are consid-erably wider than the fle*ural cracks 8.The objectives of this program were to:1. Investigate performance and mode of failure of simply supported rectangular RC beams with shear deficien-cies after strengthening with e*ternally bonded CFRP sheets.2. Addre
8、ss the factors that influence shear capacity of strengthened beams such as: steel stirrups, shear span-to-effective depth ratio (a/d ratio), and amount and distribution of CFRP.3. Increase the e*perimental database on shear strength-ening with e*ternally bonded FRP reinforcement.4. Validate the desi
9、gn approach previously proposed by the authors 9.For these objectives, 12 full-scale, RC beams designed to fail in shear were strengthened with different CFRP schemes. These members were tested as simple beams using a four-point loading configuration with two different a/d ratios.2. E*perimental pro
10、gram2.1. Test specimens and materialsTwelve full-scale beam specimens with a total span of 3050 mm. and a rectangular cross-section of 150-mm-wide and 305-mm-deep were tested. The specimens were grouped into two main series designated SW and SO depending on the presence of steel stirrups in the shea
11、r span of interest.Series SW consisted of four specimens. The details and dimensions of the specimens designated series SW are illustrated in Fig. 1a. In this series, four 32-mm steel bars were used as longitudinal reinforcement with two at top and two at bottom face of the cross-section to induce a
12、 shear failure. The specimens were reinforced with 10-mm steel stirrups throughout their entire span. The stirrups spacing in the shear span of interest, right half, was selected to allow failure in that span.Series SO consisted of eight beam specimens, which had the same cross-section dimension and
13、 longitudinal steel reinforcement as for series SW. No stirrups were provided in the test half span as illustrated.Each main series (i.e. series SW and SO) was subdivided into two subgroups according to shear span-to-effective depth ratio. This was selected to be a/d = 3 and 4, resulting in the foll
14、owing four subgroups: SW3;SW4; SO3; and SO4.The mechanical properties of the materials used for manufacturing the test specimens are listed in Table 1.Fabrication of the specimens including surface preparation and CFRP installation is described elsewhere 10.2.2. Strengthening schemesOne specimen fro
15、m each series (SW3-1, SW4-1, SO3-1 and SO4-1) was left without strengthening as a control specimen, whereas eight beam specimens were strengthened with e*ternally bonded CFRP sheets following three different schemes as illustrated in Fig. 2.In series SW3, specimen SW3-2 was strengthened with two CFR
16、P plies having perpendicular fiber directions (90/0). The first ply was attached in the form of continuous U-wrap with the fiber direction oriented perpendicular to the longitudinal a*is of the specimen (90). The second ply was bonded on the two sides of the specimen with the fiber direction paralle
17、l to the beam a*is0.This ply i.e. 0ply was selected to investigate the impact of additional horizontal restraint on shear strength.In series SW4, specimen SW4-2 was strengthened with two CFRP plies having perpendicular fiber direction (90/0) as for specimen SW3-2.Four beam specimens were strengthene
18、d in series SO3. Specimen SO3-2 was strengthened with one-ply CFRP strips in the form of U-wrap with 90-fiber orientation. The strip width was 50 mm with center-to-center spacing of 125 mm. Specimen SO3-3 was strengthened in a manner similar to that of specimen SO3-2, but with strip width equal to 7
19、5 mm. Specimen SO3-4 was strengthened with one-ply continuous U-wrap (90). Specimen SO3-5 was strengthened with twoCFRP plies (90/0) similar to specimens SW3-2 and SW4-2.In series SO4, two beam specimens were strengthened. Specimen SO4-2 was strengthened with one-ply CFRP strips in the form of U-wra
20、p similar to specimen SO3-2. Specimen SO4-3 was strengthened with one-ply continuous U-wrap (90) similar to SO3-4.2.3. Test set-up and instrumentationAll specimens were tested as simple span beams subjected to a four-point load as illustrated in Fig. 3. A universal testing machine with 1800 KN capac
21、ity was used in order to apply a concentrated load on a steel distribution beam used to generate the two concentrated loads. The load was applied progressively in cycles, usually one cycle before cracking followed by three cycles with the last one up to ultimate. The applied load vs. deflection curv
22、es shown in this paper are the envelopes of these load cycles.Four linear variable differential transformers (LVDTs) were used for each test to monitor vertical displacements at various locations as shown in Fig. 3. Two LVDTs were located at mid-span on each side of the specimen. The other two were
23、located at the specimen supports to record support settlement.For each specimen of series SW, si* strain gauges were attached to three stirrups to monitor the stirrup strain during loading as illustrated in Fig. 1a. Three strain gauges were attached directly to the FRP sheet on the sides of each str
24、engthened beam to monitor strain variation in the FRP. The strain gauges were oriented in the vertical direction and located at the section mid-height with distances of 175, 300 and 425 mm, respectively, from the support for series SW3 and SO3. For beam specimens of series SW4 and SO4, the strain ga
25、uges were located at distance of 375, 500 and 625 mm, respectively, from the support.3. Results and discussionIn the following discussion, reference is always made to weak shear span or span of interest.3.1. Series SW3Shear cracks in the control specimen SW3-1 were observed close to the middle of th
26、e shear span when the load reached appro*imately 90 kN. As the load increased, additional shear cracks formed throughout, widening and propagating up to final failure at a load of 253 kN In specimen SW3-2 strengthened with CFRP (90/0), no cracks were visible on the sides or bottom of the test specim
27、en due to the FRP wrapping. However,a longitudinal splitting crack initiated on the top surface of the beam at a high load of appro*imately 320 kN.The crack initiated at the location of applied load and e*tended towards the support. The specimen failed by concrete splitting at total load of 354 kN.
28、This was an increase of 40% in ultimate capacity pared to the control specimen SW3-1. The splitting failure was due to the relatively high longitudinal pressive stress developed at top of the specimen, which created a transverse tension, led to the splitting failure. In addition, the relatively larg
29、e amount of longitudinal steel reinforcement bined with over-strengthening for shear by CFRP wrap probably caused this mode of failure. The load vs. mid-span deflection curves for specimens SW3-1 and SW3-2 are illustrated , to show the additional capacity gained by CFRP.The ma*imum CFRP vertical str
30、ain measured at failure in specimen SW3-2 was appro*imately 0.0023 mm/mm, which corresponded to 14% of the reported CFRP ultimate strain. This value is not an absolute because it greatly depends on the location of the strain gauges with respect to a crack. However, the recorded strain indicates that
31、 if the splitting did not occur, the shear capacity could have reached higher load.parison between measured local stirrup strains in specimens SW3-1 and SW3-2 are shown in Fig. 6. The stirrups 1, 2 and 3 were located at distance of 175, 300 and 425 mm from the support, respectively. The results show
32、ed that the stirrups 2 and 3 did not yield at ultimate for both specimens. The strains (and the forces) in the stirrups of specimen SW3-2 were, in general, smaller than those of specimen SW3-1 at the same level of loading due to the effect of CFRP.3.2. Series SW4In specimen SW4-1, the first diagonal
33、 crack was formed in the member at a total applied load of 75 kN. As the load increased, additional shear cracks appeared throughout the shear span. Failure of the beam occurred when the total applied load reached 200 kN. This was a decrease of 20% in shear capacity pared to the specimen SW3-1 In sp
34、ecimen SW4-2, the failure was controlled by concrete splitting similar to test specimen SW3-2. The total applied load at ultimate was 361 kN with an 80% increase in shear capacity pared to the control specimen SW4-1. In addition, the measured strains in the stirrups for specimen SW4-2 were less than
35、 those of specimen SW4-1. The applied load vs. mid-span deflection curves for beams SW4-1 and SW4-2 are illustrated . It may be noted that specimen SW4-2 resulted in greater deflection when pared to specimen SW4-1.When paring the test results of series SW3 specimens to that of series SW4, the ultima
36、te failure load of specimen SW3-2 and SW4-2 was almost the same. However, the enhanced capacity of specimen SW3-2 (a/d=3) due to the addition of the CFRP reinforcement was 101 kN, while specimen SW4-2 (a/d=4) was 161 kN. This indicates that the contribution of e*ternal CFRP reinforcement may be infl
37、uenced by the ayd ratio and appears to decrease with a decreasing a/d ratio. Further, for both strengthened specimens (SW3-2 and SW4-2), CFRP sheets did not fracture or debond from the concrete surface at ultimate and this indicates that CFRP could provide additional strength if the beams did not fa
38、iled by splitting.3.3. Series SO3Fig. 8 illustrates the failure modes for series SO3 specimens. That details the applied load vs. mid-span deflection for the specimens.The failure mode of control specimen SO3-1 was shear pression. Failure of the specimen occurred at a total applied load of 154 kN. T
39、his load was a decrease of shear capacity by 54.5 kN pared to the specimen SW3-1 due to the absent of the steel stirrups. In addition, the crack pattern in specimen SW3-1 was different from of specimen SO3-1. In specimen SW3-1, the presence of stirrups provided a better distribution of diagonal crac
40、ks throughout the shear span.In specimen SO3-2, strengthened with 50-mm CFRP strips spaced at 125 mm, the first diagonal shear crack was observed at an applied load of 100 kN. The crack propagated as the load increased in a similar manner to that of specimen SO3-1. Sudden failure occurred due to deb
41、onding of the CFRP strips over the diagonal shear crack, with spalled concrete attached to the CFRP strips. The total ultimate load was 262 kN with a 70% increase in shear capacity over the control specimen SO3-1. The ma*imum local CFRP vertical strain measured at failure in specimen SO3-2 was 0.004
42、7 mm/mm (i.e. 28% of the ultimate strain), which indicated that the CFRP did not reach its ultimate.Specimen SO3-3, strengthened with 75-mm CFRP strips failed as a result of CFRP debonding at a total applied load of 266 kN. No significant increase in shear capacity was noted pared to specimen SO3-2.
43、 The ma*imum-recorded vertical CFRP strain at failure was 0.0052 mmymm (i.e. 31% of the ultimate strain). Specimen SO3-4, which was strengthened with a continuous CFRP U-wrap (908), failed as a result of CFRP debonding at an applied load of 289 kN. Results show that specimen SO3-4 e*hibited increase
44、 in shear capacity of 87, 10 and 8.5% over specimens SO3-1,SO3-2 and SO3-3, respectively. Applied load vs. vertical CFRP strain for specimen SO3-4 is illustrated in Fig. 10 in which strain gauges sg1, sg2 and sg3 were located at mid-height with distances of 175, 300 and 425 mm from the support, resp
45、ectively. Fig. 10 shows that the CFRP strain was zero prior to diagonal crack formation, then increased slowly until the specimen reached a load in the neighborhood of the ultimate strength of the control specimen. At this point, the CFRP strain increased significantly until failure. The ma*imum loc
46、al CFRP vertical strain measured at failure was appro*i- mately 0.0045 mm/mm.When paring the results of beams SO3-4 and SO3-2, the CFRP amount used to strengthen specimen SO3-4 was 250% of that used for specimen SO3-2. Only a 10% increase in shear capacity was achieved for the additional amount of C
47、FRP used. This means that if an end anchor to control FRP debonding is not used, there is an optimum FRP quantity, beyond which the strengthening effect is questionable. A previous study 11 showed that by using an end anchor system, the failure mode of FRP debonding could be avoided. Reported findin
48、gs are consistent with those of other research 7, which was based on a review of the e*perimental results available in the literature, and indicated that the contribution of FRP to the shear capacity increases almost linearly, with FRP a*ial rigidity e*pressed by ( is the FRP area fraction and is th
49、e FRP elastic modulus) up to appro*imately 0.4 GPa. Beyond this value, the effectiveness of FRP ceases to be positive.In specimen SO3-5, the use of a horizontal ply over the continuous U-wrap (i.e. 90/0) resulted in a concrete splitting failure rather than a CFRP debonding failure. The failure occur
50、red at total applied load of 339 kN with a 120% increase in the shear capacity pared to the control specimen SO3-1. The strengthening with two perpendicular plies (i.e. 90/0) resulted in a 17% increase in shear capacity pared to the specimen with only one CFRP ply in 90 orientation (i.e. specimen SO
51、3-4). The ma*imum local CFRP vertical strain measured at failure was 0.0043 mm/mm.By paring the test results of specimens SW3-2 and SO3-5, having the same a/d ratio and strengthening schemes but with different steel shear reinforcement, the shear strength (i.e. 177 and 169.5 kN for specimens SW3-2 a
52、nd SO3-5, respectively), and the ductility are almost identical. One may conclude that the contribution of CFRP benefits the beam capacity to a greater degree for beams without steel shear reinforcement than for beams with adequate shear reinforcement.3.4. Series SO4Series SO4 e*hibited the largest
53、increase in shear capacity pared to the other series investigated with this research study. The e*perimental results in terms of applied load vs mid-span deflection for this series is illustrated in Fig. 11.The control specimen SO4-1 failed as a result of shear pression at a total applied load of 13
54、0 kN. Specimen SO4-2, strengthened with CFRP strips, the failure was controlled by CFRP debonding at a total load of 255 kN with 96% increase in shear capacity over the control specimen SO4-1. The ma*imum local CFRP vertical strain measured at failure was 0.0062mmymm. When paring the test results of
55、 specimen SO4-2 to that of specimen SO3-2, the enhanced shear capacity of specimen SO4-2 (a/d=4) due to addition of CFRP strips was 62.5 kN, while specimen SO3-2 (a/d=3) resulted in added shear capacity of 54 kN. As e*pected, the contribution of CFRP reinforcement to resist the shear appeared to dec
56、rease with decreasing a/d ratio. Specimen SO4-3, strengthened with continuous U- wrap, failed as a result of concrete splitting at an applied load of 310 kN with a 138% increase in shear capacity pared to that of specimen SO4-1. The ma*imum local CFRP vertical strain measured at failure was 0.0037 m
57、m/mm.4. Design approachThe design approach for puting the shear capacity of RC beams strengthened with e*ternally bonded CFRP reinforcement, e*pressed in ACI design code 12 format, was proposed and published in 1998 13. The design model described two possible failure mechanisms of CFRP reinforcement
58、 namely: CFRP fracture; and CFRP debonding. Furthermore, two limits on the contribution of CFRP shear were proposed. The first limit was set to control the shear crack width and loss of aggregate interlock, and the second was to preclude web crushing. Also, the concrete strength and CFRP wrap- ping
59、schemes were incorporated as design parameters. In recent study 9,10, modifications were proposed to the 1998 design approach to include results of a new study on bond mechanism between CFRP sheets and concrete surface 14. In addition, the model was e*tended to provide the shear design equations in
60、Eurocode as well as ACI format. paring with all test results available in the literature to date, 76 tests, the design approach showed acceptable and conservative estimates 10,13. In this section, the summary of the designapproach is presented. The parison between e*perimental results and the calcul
溫馨提示
- 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 二零二五年度抗滑樁施工環(huán)保與綠色施工協(xié)議2篇
- 2024版:臨時(shí)拆除工程合同模板
- 小區(qū)居民的消防安全意識(shí)提升策略研究
- 二零二五年度安置房買賣合同社區(qū)共建共治共享協(xié)議范本3篇
- 2024年食品加工合作伙伴合同3篇
- 商業(yè)餐飲企業(yè)如何應(yīng)對(duì)學(xué)生營(yíng)養(yǎng)餐市場(chǎng)變化
- 小學(xué)數(shù)學(xué)思維訓(xùn)練的核心策略與方法
- 二零二五年度特色農(nóng)產(chǎn)品種植承包合同2篇
- 二零二五年度文化創(chuàng)意產(chǎn)業(yè)廠房股權(quán)轉(zhuǎn)讓合同書3篇
- 二零二五年度物聯(lián)網(wǎng)系統(tǒng)建設(shè)合同2篇
- 2024-2030年中國(guó)液態(tài)金屬行業(yè)市場(chǎng)分析報(bào)告
- 住宅樓智能化系統(tǒng)工程施工組織設(shè)計(jì)方案
- 福建省廈門市2023-2024學(xué)年高一上學(xué)期1月期末質(zhì)量檢測(cè)數(shù)學(xué)試題 附答案
- 高二上學(xué)期數(shù)學(xué)北師大版(2019)期末模擬測(cè)試卷A卷(含解析)
- 2024總經(jīng)理年終總結(jié)及2024工作計(jì)劃
- 全新照顧老人保姆合同協(xié)議書下載
- 三里屯派出所調(diào)解賠償協(xié)議書范文
- 第一單元:復(fù)習(xí)與提高(單元復(fù)習(xí)講義)-滬教版五年級(jí)數(shù)學(xué)下冊(cè)
- 國(guó)土空間規(guī)劃用途管制實(shí)施與研究
- 2024年江蘇省中考英語(yǔ)試卷十一套合卷附答案
- 智慧康養(yǎng)社區(qū)項(xiàng)目資金申請(qǐng)報(bào)告-超長(zhǎng)期特別國(guó)債投資專項(xiàng)
評(píng)論
0/150
提交評(píng)論