1、S400 Technical Summary (201112)MBCLRegion EastVictor LuoMercedes-Benz (China) Ltd.Topic: Vehicle idle time/charge retention HV batteryModel: 221 hybridSpecification: SI54.10-P-0027A After a 6 week idle period, check/charge HV battery. If the vehicle is parked for an extended period, the HV battery s
2、hould have reached the maximum achievable charge level of 55% SOC for an internal combustion engine. A charge retention via 12 V battery will not prevent the HV battery from self-discharging. HV battery charge retention is not possible. Basic 1. Maximum possible charge level with internal combustion
3、 engine 55% SOC data: 2. Minimum charge level (automatic start of internal combustion engine) 30% SOC 3. Minimum charge level (start capability) 15% SOC Self-discharge of HV battery 10% SOC per 4 weeksBest case: 55% SOC -15% SOC (start capability) =40% SOC = 16 weeksWorst case: 30% SOC -15% SOC (sta
4、rt capability) = 15% SOC = 6 weeksMercedes-Benz (China) Ltd.Region East After-SalesMercedes-Benz (China) Ltd.Topic: Deep discharged single cell HV batteryModel: 221 hybridCause: Contamination in cell chemistry results in increased self-discharge of single cells. ( 2 mV/day)Remedy: Replace HV battery
5、Diagnosis: Xentry diagnosis access via BMS control unit Actual values Single cell voltages and fault code entries: 0BBE00 / 0BBD00 in BMS control unitDamage code: 54719Replacement part: A 221 343 05 00Standard: Various quality measures at suppliers and a screening of the single cell voltages on the
6、line enabled a major reduction in early failures to be achieved. Implementation: 2211A 302290Mercedes-Benz (China) Ltd.Region East After-SalesMercedes-Benz (China) Ltd.Topic: Deep discharged single cell HV batteryExample: Diagnosis printout for single cell voltages Discharged single cellsMercedes-Be
7、nz (China) Ltd.Region East After-SalesMercedes-Benz (China) Ltd.Mercedes-Benz (China) Ltd.Topic: Excessively discharged single cell of the high voltage battery (self discharge)Type: 221.095 & 221.195 (S400 Hybrid)Cause: Contaminants e.g. iron or copper particles either from dentrites over time or me
8、chanically break through the seperator during the production of the cellDTC: SG-BMS 0BBD00, 0BBE00Remedy (Series): - Optimized pre-treatment of the materials in the cell production Extended individual battery testing in the vehicle plan before installation in the vehicle. Clean point: 092011 (FIN: W
9、DD2211951A441817)Remedy (service): Perform replacement of the high voltage batteryMercedes-Benz (China) Ltd.Mercedes-Benz (China) Ltd.Cause: Please refer to TIPS document LI01.10-P-048929Remedy: Under investigation from R/D TIPS Case mandatory !Technical solution will be communicated case by case vi
10、a the TIPS case moduleModel: S400 Hybrid (221195)Complaint: Abnormal engine noiseMercedes-Benz (China) Ltd.Mercedes-Benz (China) Ltd.Test GuidelineIf the complaint could be confirmed as an abnormal engine noise, please1.) Open a TIPS case and implement the following: Pre-Order or Job card with custo
11、mer signature Initial Quick Test Log from DAS with actual DAS Add-On installed Control Unit Log from ME Repair History of the vehicle Check & verify the complaint as per TIPS Document LI01.10-P-048929 Confirm the engine speed on which this noise get noticed Make a sound record of the engine sound an
12、d attach it to the TIPS case Send TIPS case to Regional Office If the engine noise could be confirmed as per LI01.10-P-048929, then please follow step 2.), if not, then follow the step 3.) Mercedes-Benz (China) Ltd.Mercedes-Benz (China) Ltd.2.) RO will check the TIPS case and advise the workshop to
13、Remove the alternator belt (for test purpose only) and check the influence of the noise Shut off the cylinder 1 to 6 and check if there is any influence of the noise Check also the influence of the noise from parking position into “N” and into “D” Take three video clips (incl. sound!) for belt drive
14、 at left engine side (oil temperature 90., coolant temperature 90.) 1. With alternator belt for constant engine RPM with the noise for at least 30s 2. Without alternator belt for constant engine RPM with the noise for at least 30s 3. Without alternator belt, increase the engine speed to 2,500 rpm an
15、d then release the gas pedal until the engine speed come down to app. 1,500 rpm, repeat at least 10 times Mercedes-Benz (China) Ltd.Mercedes-Benz (China) Ltd.Send the TIPS Case with all the details back to the Regional Office Follow step 3.) 3.) Central Office will take over the case, check it and i
16、f necessary forward it to DAG. Wait for further instructions via the TIPS case module. Note: Never dismantle the engine without pre-approval via TIPS case through the Regional or Central Office for such complaint. Take pictures from the crank case as the sample besides (Both the numbers from the low
17、er part and the pins from the upper part!) Mercedes-Benz (China) Ltd.Topic: Mounting bolt for HV connector to HV battery broken during assemblyModel: 221 Hybrid (221.095 and 221.195)Cause: Excessive stress on mounting bolt as a consequence of not adhering to tightening torque of 5 Nm.Remedy: Replace
18、 mounting bolt as described in TIPS document GI54.10-P-048638. A special repair kit (A 000 542 33 73) has been defined at GLC for this purpose.Standard: Material change for mounting bolt from brass to steel (CW 06/10) tightening torque remains 5 Nm!Damage code: 5960A 06Note: Tightening torque of 5 N
19、m must be observed!Mercedes-Benz (China) Ltd.Region East After-SalesMercedes-Benz (China) Ltd.Mercedes-Benz (China) Ltd.Complaint: Check engine light is on, Fault code P06DA00 engine oil pump valve fault)Cause: engine oil pump valve Y130Solution:There is no individual part available. The oil pump is
20、 to replaceOil pump valveY130 Oil pump valveModel: S400 with M272.974Mercedes-Benz (China) Ltd.Cause: The contact of the ground line between the DC/DC converter and vehicle body is inadequate. DC/DC converter is in standby mode (FC:P1C7000).1. Ground terminal on housing2. Ground terminal on vehicleT
21、opic: Engine start / stop system; engine starts up or 12V on-board electrical system voltage too lowType: 221.095 & 221.195 (S400 Hybrid)Mercedes-Benz (China) Ltd.Color residue on contact surface1. Ground cable crimp 2. Torque insufficientOxidation on housing Topic: Engine start / stop system: engin
22、e starts up or 12V on-board electrical system voltage too lowType: 221.095 & 221.195 (S400 Hybrid)Cause:Mercedes-Benz (China) Ltd.Remedy: 1. Rework contact surface of the ground terminal at the housing of the DC/DC converter according to TIPS document GI54.10-P-0489992. Perform programming of the DC
23、/DC converter with current SW (10.20.00)3. Check resistance of the ground line with DAS/XD guided test(as of 03/11)4. Perform SCN coding to the SAM driver (Modified charging current regulation of the generator)Further measurementsPerform engine control unit programming as of DAS/XD 05/2011. (In case
24、 of 12V under voltage, the yellow “READY” indication lamp will be displayed permanently in the IC and no automatic engine stop will be available)Perform programming to the DC/DC converter as of DAS/XD 07/2011 (threshold adaptation regarding ground line)Series: Modification of the ground terminal con
25、nection (M8 instead of M6), new DC/DC converter software will be in production as of 07/2011Topic: Engine start / stop system; engine starts up or 12V on-board electrical system voltage too lowType: 221.095 & 221.195 (S400 Hybrid)Mercedes-Benz (China) Ltd.Mercedes-Benz (China) Ltd.Topic: defective f
26、use (150A) of the HV batteryType: 221.095 & 221.195 (S400 Hybrid)Cause: Thermo-mechanical aging as a result of alternating electrical load (Bending)DTC: SG-BMS 0AA700, 0C7800, 0A1F04Remedy (Series): Use of the Fuse Temperature Control Function (FTCF) software for reduced temperature differences on t
27、he high voltage fuse. This means significantly lower mechanical and thermal stressClean point: 092011 (FIN: WDD2211951A441817)Remedy (Service):Current complaint: Replacement of the high voltage batteryPreventive: Service measure is currently in preparation (re-programming of the SG-BMS)Mercedes-Benz
28、 (China) Ltd.Mercedes-Benz (China) Ltd.Topic: High decrementation of the contractor aging counter of the high voltage batteryType: 221.095 & 221.195 (S400 Hybrid)Function: The counter describes the wear of the HV relay contacts when opening the contacts by spark erosion over lifetime. When the conta
29、cts open, the counter is decremented in dependence of the current intensity (see table). The counter is factory set to “200.000” when opening the contactor under normal conditions (e.g. ignition “OFF”) the counter will be decremented by “1”DAS/XD: Counter value in SG-BMS control unit protocolService
30、: From a counter value of “150.000” a message is displayed in the DAS/XD as of now to have the workshop create a TIPS case.Mercedes-Benz (China) Ltd.Mercedes-Benz (China) Ltd.Topic: Air conditioning is permanently inoperable defective 60A fuse inside PDU -Type: 221.095 & 221.195 (S400 Hybrid)Cause:
31、Thermally induced material fatigue as a result of a variety of electrical pulsesDTC: No error code in DAS/XentryService:Function test of the 60A fuse according TIPS document GI83.30-P-050078.If the fuse is defective, the power electronics (incl. PDU) has to be replaced.Mercedes-Benz (China) Ltd.Merc
32、edes-Benz (China) Ltd.Topic: Defect of the DC-link capacitor (PCC) of the power electronics unit (1/2)Type: 221.095 & 221.195 (S400 Hybrid)Cause: Loss of contact between bus bar and capacitor package. This leads to a progressive loss of capacity of the PCC capacitor. As a result of the loss of capac
33、ity the voltage ripple in the DC link increases followed by a defect of the power supply for the power electronics. Depending on the level of the voltage ripple, the 30A fuse of the high voltage battery might be damaged.DTC: P0A1E00,P0AFB00,P0A5D00,P0A6000,P0A6300Service: Replace the power electroni
34、cs unitMercedes-Benz (China) Ltd.Mercedes-Benz (China) Ltd.Topic: Defect of the DC-link capacitor (PCC) of the power electronics unit (2/2)Cause: As a result of the effect, the 60F capacitor in the DC/DC converter takes over the smoothing function increasingly. The increases the peak currents which might lead into triggering the 30A fuse in the high voltage battery.DTC: No DTCs in DAS/XentryServic
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 2025年度數(shù)據(jù)中心運(yùn)營維護(hù)承包人工合同模板4篇
- 2025年度互聯(lián)網(wǎng)數(shù)據(jù)中心搭建服務(wù)合同協(xié)議3篇
- 2025年度化工原料采購與儲存協(xié)議3篇
- 2025年度環(huán)保型綠色打印設(shè)備承包合同范本3篇
- 2025年度汽車4S店集團(tuán)購車優(yōu)惠及售后服務(wù)協(xié)議3篇
- 2024衣柜墻板吊頂裝修工程施工安全與環(huán)境保護(hù)合同
- 創(chuàng)新集成電路設(shè)計(jì)與制造技術(shù)項(xiàng)目可行性研究報(bào)告范文模板
- 《融資租賃行業(yè)培訓(xùn)》課件
- 2025年度房產(chǎn)中介服務(wù)傭金結(jié)算標(biāo)準(zhǔn)合同4篇
- 2025年度別墅裝修工程承包與監(jiān)理協(xié)議4篇
- 二零二五年度數(shù)據(jù)存儲與備份外包服務(wù)協(xié)議2篇
- 家政服務(wù)與社區(qū)合作方案
- 2024年深圳市龍崗區(qū)城市建設(shè)投資集團(tuán)有限公司招聘筆試真題
- 2024-2025學(xué)年北京市朝陽區(qū)高三上學(xué)期期末考試數(shù)學(xué)試卷(含答案)
- 第五單元《習(xí)作例文:風(fēng)向袋的制作》說課稿-2024-2025學(xué)年五年級上冊語文統(tǒng)編版
- 四年級數(shù)學(xué)(除數(shù)是兩位數(shù))計(jì)算題專項(xiàng)練習(xí)及答案
- 四川省綿陽市涪城區(qū)2024-2025學(xué)年九年級上學(xué)期1月期末歷史試卷(含答案)
- 2025年山東水發(fā)集團(tuán)限公司社會招聘高頻重點(diǎn)提升(共500題)附帶答案詳解
- JJG 1204-2025電子計(jì)價(jià)秤檢定規(guī)程(試行)
- 2024年計(jì)算機(jī)二級WPS考試題庫(共380題含答案)
- 《湖南省房屋建筑和市政工程消防質(zhì)量控制技術(shù)標(biāo)準(zhǔn)》
評論
0/150
提交評論