![深圳某辦公樓中央空調(diào)畢業(yè)設(shè)計(jì)_第1頁(yè)](http://file4.renrendoc.com/view/08569ddb856d71d46915c7f2ff875e86/08569ddb856d71d46915c7f2ff875e861.gif)
![深圳某辦公樓中央空調(diào)畢業(yè)設(shè)計(jì)_第2頁(yè)](http://file4.renrendoc.com/view/08569ddb856d71d46915c7f2ff875e86/08569ddb856d71d46915c7f2ff875e862.gif)
![深圳某辦公樓中央空調(diào)畢業(yè)設(shè)計(jì)_第3頁(yè)](http://file4.renrendoc.com/view/08569ddb856d71d46915c7f2ff875e86/08569ddb856d71d46915c7f2ff875e863.gif)
![深圳某辦公樓中央空調(diào)畢業(yè)設(shè)計(jì)_第4頁(yè)](http://file4.renrendoc.com/view/08569ddb856d71d46915c7f2ff875e86/08569ddb856d71d46915c7f2ff875e864.gif)
![深圳某辦公樓中央空調(diào)畢業(yè)設(shè)計(jì)_第5頁(yè)](http://file4.renrendoc.com/view/08569ddb856d71d46915c7f2ff875e86/08569ddb856d71d46915c7f2ff875e865.gif)
版權(quán)說(shuō)明:本文檔由用戶(hù)提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡(jiǎn)介
摘要本設(shè)計(jì)為深圳市某實(shí)業(yè)有限公司辦公樓中央空調(diào)系統(tǒng),擬為之設(shè)計(jì)合理的中央空調(diào)系統(tǒng),為室內(nèi)工作人員提供舒適的工作環(huán)境。系統(tǒng)采用風(fēng)機(jī)盤(pán)管為主承擔(dān)空調(diào)房間的冷負(fù)荷與熱負(fù)荷,每個(gè)房間的吊頂內(nèi)安置一到二個(gè)暗裝風(fēng)機(jī)盤(pán)管。新風(fēng)則通過(guò)獨(dú)立的新風(fēng)管道先送入風(fēng)機(jī)盤(pán)管,再與回風(fēng)混合一起送入房間。新風(fēng)機(jī)組安裝于新風(fēng)機(jī)房?jī)?nèi),每一層樓放置兩臺(tái)新風(fēng)機(jī)組負(fù)擔(dān)該層所有空調(diào)房間的新風(fēng),該空調(diào)系統(tǒng)的優(yōu)點(diǎn)是占用建筑面積少,可集中供冷和供熱。同時(shí)各末端裝置有獨(dú)立的開(kāi)關(guān)和調(diào)節(jié)功能,各房間的溫度可獨(dú)自調(diào)節(jié)與控制,且防止了空氣的交叉感染。關(guān)鍵字:辦公樓;中央空調(diào);風(fēng)機(jī)盤(pán)管—新風(fēng)系統(tǒng);性能比較。ThegraduationprojectdesignsacentralairconditioningsystemforXXofficialbuildinginShenzhenCity,soastocreateacomfortableworkenvironmentforthestuff.Thissystemmainlyadoptsthetmantidotetoundertaketheairconditionro11om’scoolingloadsandhotloads.Eachroom’sceilingsettlesoneortwoair-conditionsinside.Theindependentfreshairissentintothermantidotebytheindependentfreshairmachinefirstly,andthenmixedwiththesecond-usedairandsentintotheroomtogether.Theindependentfreshairmachineisinstalledinthefreshairmachineroom.Eachfloorplacestwoindependentfreshairmachinestosupporttheindependentfreshairforalltheairconditionsroominthatfloor.Theadvantageoftheaircondition’ssystemisthatiscanreducethebuildingarea,itcanbothprovidewithquantityofcoldandquantityofheat.Eachthermantidotehavethefunctionofregulatingindependently,thetemperatureofeachroomcanbecontrolledalone,andtheindependentfreshaircanbesentintoairconditionroomsystematically.Itcontains:coolingloadcalculation;theestimationofsystemzoning;theselectionofrefrigerationunits;theselectionofairconditioningequipments;thedesignofairductsystemandcalculation;theestimationofairdistributionmethodandtheselectionofrelevantequipments;thedesignofwatersystemanditsresistanceanalysis;theinsulationofairductplantandchilledwaterpipes;noiseandvibrationcontrol;etc.Accordingtosomecorrelationstandard,allowforenergysafeandindoorcomfort,theairconditionsystemofthedesignisFancoilunits(FCUs)--freshairsystem.Keywords:officialbuilding;Centralairconditioning;Fancoilunits(FCUs)--freshairsystem;Thefunctioncompare.1緒論1.1我國(guó)暖通空調(diào)的現(xiàn)狀及其發(fā)展進(jìn)入上世紀(jì)90年代后,我國(guó)的居住環(huán)境和工業(yè)生產(chǎn)環(huán)境都已廣泛地應(yīng)用空調(diào),空調(diào)技術(shù)已成為衡量建筑現(xiàn)代化水平的重要標(biāo)志之一。90年代中期,由于大中城市電力供應(yīng)緊張,供電部門(mén)開(kāi)始重視需求管理及削峰填谷,蓄冷空調(diào)技術(shù)提到了議事日程。近年來(lái),由于能源結(jié)構(gòu)的變化,促進(jìn)了吸收式冷熱水機(jī)組的快速發(fā)展,以及熱泵技術(shù)在長(zhǎng)江中下游地區(qū)的應(yīng)用。隨著生產(chǎn)和科技的不斷發(fā)展,人類(lèi)對(duì)空調(diào)技術(shù)也進(jìn)行了一系列的改進(jìn),同時(shí)也在積極研究環(huán)保、節(jié)能的空調(diào)產(chǎn)品和技術(shù),已經(jīng)投入使用了冰蓄冷空調(diào)系統(tǒng)、燃?xì)饪照{(diào)、VAV空調(diào)系統(tǒng)、地源熱泵系統(tǒng)等。暖通空調(diào)技術(shù)的發(fā)展,必然會(huì)受到能源、環(huán)境條件的制約,所以能源的綜合利用、節(jié)能、保護(hù)環(huán)境及趨向自然的舒適環(huán)境必然是今后發(fā)展的主題。1.2建筑空調(diào)系統(tǒng)節(jié)能?chē)?guó)內(nèi)外研究現(xiàn)狀1.2.1建筑空調(diào)建筑空調(diào)系統(tǒng)節(jié)能?chē)?guó)外研究現(xiàn)狀能源是整個(gè)經(jīng)濟(jì)系統(tǒng)的基本組成部份,作為一個(gè)能源消耗大國(guó),美國(guó)在節(jié)能和提高能源利用率方面投入了大量的人力、物力。在美國(guó)的整個(gè)能源消耗中,有約1/3以上消耗在建筑能耗上,這些能耗用來(lái)滿(mǎn)足人們的熱舒適、空氣品質(zhì)、提高人們的生活質(zhì)量。美國(guó)暖通空調(diào)制冷工程師協(xié)會(huì)、美國(guó)制冷協(xié)會(huì)、美國(guó)冷卻塔協(xié)會(huì)等組織、美國(guó)能源部以及眾多暖通空調(diào)設(shè)備生產(chǎn)廠(chǎng)家如York,Carrier等都為建筑節(jié)能做出了很大貢獻(xiàn)。特別是美國(guó)制冷設(shè)備生產(chǎn)廠(chǎng)商投入了大量的資源研究高性能冷水機(jī)組,使得冷水機(jī)組單位制冷量的能耗僅為20世紀(jì)70年代的62.3%。美國(guó)在空調(diào)冷源水系統(tǒng)方面的研究也卓有成效,在冷卻水系統(tǒng)方面著重于降低冷卻水流量,以達(dá)到減少冷卻水泵能耗的目的。日本是一個(gè)資源貧困的國(guó)家,其主要能源來(lái)自進(jìn)口,同時(shí)又是一個(gè)能源高消費(fèi)國(guó)家。因此,節(jié)能和提高能源的利用率對(duì)日本來(lái)講有著重要的意義。長(zhǎng)期以來(lái),在建筑節(jié)能方面,日本做了大量工作,頒布了許多節(jié)能法規(guī),提出了建筑節(jié)能的評(píng)價(jià)方法。日本的一些設(shè)備生產(chǎn)廠(chǎng)家對(duì)空調(diào)和制冷設(shè)備的投入也很大。Daikin公司首推的變頻VRV系統(tǒng),為中小型建筑安裝集中式空調(diào)系統(tǒng)創(chuàng)造了條件;Sany公司則在直燃式冷水機(jī)組上成績(jī)卓著。世界各國(guó)大力發(fā)展可再生能源作為空調(diào)冷熱源用能。地源熱泵供暖空調(diào)是一種使用可再生能源的高效節(jié)能、環(huán)保型的工程系統(tǒng)。在美國(guó)地源熱泵系統(tǒng)占整個(gè)空調(diào)系統(tǒng)的20%左右;瑞士40%的熱泵為地禍熱泵,瑞典65%的熱泵為地禍熱泵。1.2.2建筑空調(diào)系統(tǒng)節(jié)能?chē)?guó)內(nèi)研究現(xiàn)狀我國(guó)是一個(gè)人均資源相對(duì)貧乏的國(guó)家,因此節(jié)能降耗有著十分重要的意義。近年來(lái),由于國(guó)民經(jīng)濟(jì)的快速發(fā)展,使我國(guó)的能源顯得越來(lái)越緊張。(1)建筑空調(diào)系統(tǒng)節(jié)能?chē)?guó)內(nèi)研究現(xiàn)狀概況隨著經(jīng)濟(jì)建設(shè)的不斷深入和人們生活水平的不斷提高,空調(diào)建筑物越來(lái)越多,建筑物消耗的能量也越來(lái)越大,甚至出現(xiàn)了空調(diào)系統(tǒng)與經(jīng)濟(jì)建設(shè)爭(zhēng)搶電力資源的情況。因此,在建筑物節(jié)能顯得十分迫切。在我國(guó)建筑總能耗中,空調(diào)系統(tǒng)的能耗占有相當(dāng)大的比重,因此研究探討空調(diào)系統(tǒng)的節(jié)能就顯得十分重要。在建筑物空調(diào)系統(tǒng)運(yùn)行能耗中,冷源系統(tǒng)的能耗是最大的。近年來(lái),我國(guó)暖通空調(diào)學(xué)術(shù)界和工程界在空調(diào)冷源系統(tǒng)的節(jié)能方面做了大量的研究工作。研究工作主要集中在冷源系統(tǒng)的形式選擇上,對(duì)壓縮式冷水機(jī)組和吸收式冷水機(jī)組的技術(shù)經(jīng)濟(jì)比較研究較多,通過(guò)對(duì)眾多方案的分析已經(jīng)基本達(dá)成共識(shí):吸收式冷水機(jī)組節(jié)電而不節(jié)能,對(duì)其在我國(guó)的應(yīng)用應(yīng)區(qū)別對(duì)待,對(duì)于有余熱可以利用的地區(qū),應(yīng)大力提倡使用吸收式冷水機(jī)組,而一般建筑物則應(yīng)采用蒸汽壓縮式制冷。當(dāng)然,在進(jìn)行冷熱源系統(tǒng)的選擇時(shí),還要考慮建筑物所在地的氣象條件、電力供應(yīng)狀況、能源情況、空調(diào)系統(tǒng)有無(wú)采用余熱回收的可能性等方面的問(wèn)題。(2)我國(guó)建筑空調(diào)系統(tǒng)節(jié)能研究有待解決的問(wèn)題通過(guò)對(duì)一些地區(qū)空調(diào)系統(tǒng)的調(diào)查發(fā)現(xiàn),設(shè)計(jì)人員在涉及選用冷水機(jī)組時(shí)多考慮其額定工況下的全負(fù)荷性能,而對(duì)其部分負(fù)荷性能的考慮較少。在風(fēng)冷式冷水機(jī)組和水冷式冷水機(jī)組的選擇應(yīng)用上我國(guó)制冷工程界也存在著認(rèn)識(shí)上的差異。我國(guó)在冷源水系統(tǒng)方面的研究目前較少,一般都是按冷水機(jī)組的樣本提供的冷卻水量和冷凍水量進(jìn)行冷卻水泵和冷凍水泵的選擇。對(duì)于水系統(tǒng)的水泵是否運(yùn)行節(jié)能則關(guān)注不多。事實(shí)上,對(duì)于冷水機(jī)組的運(yùn)行而言,冷凝器和蒸發(fā)器都要求定流量,因此,對(duì)于冷水機(jī)組部分負(fù)荷狀態(tài)運(yùn)行時(shí),水泵的輸出都是全負(fù)荷輸出,水系統(tǒng)的全年運(yùn)行能耗是相當(dāng)大的。因此水系統(tǒng)的節(jié)能具有很大的潛力。1.3空調(diào)系統(tǒng)的設(shè)計(jì)與建筑節(jié)能空調(diào)制冷技術(shù)的誕生是建筑技術(shù)史一項(xiàng)重大進(jìn)步,它標(biāo)志著人類(lèi)從被動(dòng)適應(yīng)宏觀自然氣候發(fā)展到主動(dòng)控制建筑微氣候,在改造和征服自然的過(guò)程的又邁出了堅(jiān)實(shí)的一步。但是對(duì)空調(diào)的依賴(lài)也逐漸成為建筑能耗增長(zhǎng)的最主要的原因。制冷空調(diào)系統(tǒng)的出現(xiàn)為人們創(chuàng)造了舒適的空調(diào)環(huán)境,但20世紀(jì)70年代的全球能源危機(jī),使制冷空調(diào)系統(tǒng)這一能源消耗大戶(hù)面臨嚴(yán)重考驗(yàn),節(jié)能降耗成為空調(diào)系統(tǒng)設(shè)計(jì)的關(guān)鍵環(huán)節(jié)。據(jù)統(tǒng)計(jì),我國(guó)建筑能耗約占全國(guó)總能能耗的35%,空調(diào)能耗又約占建筑能耗的50%~60%左右。由此可見(jiàn),暖通空調(diào)能耗占總能耗的比例可高達(dá)22.75%。因此,建筑中的空調(diào)系統(tǒng)節(jié)能已成為節(jié)能領(lǐng)域中的一個(gè)重點(diǎn)和熱點(diǎn)。于是降低空調(diào)能耗也被納于建筑節(jié)能的任務(wù)中,如何更好的利用現(xiàn)在的空調(diào)技術(shù)服務(wù)人類(lèi)同時(shí)又能滿(mǎn)足建筑能耗的要求,是現(xiàn)階段專(zhuān)業(yè)技術(shù)人員的工作要點(diǎn)。而暖通空調(diào)設(shè)計(jì)方案的好壞直接影響著建筑環(huán)境的質(zhì)量和節(jié)能狀況。隨著科學(xué)技術(shù)的迅速發(fā)展以及對(duì)節(jié)能和環(huán)保要求的不斷提高,暖通空調(diào)領(lǐng)域中新的設(shè)計(jì)方案大量涌現(xiàn),針對(duì)同一個(gè)設(shè)計(jì)項(xiàng)目,往往可以有很多不同的設(shè)計(jì)方案可供選擇,設(shè)計(jì)人員要進(jìn)行大量的方案比較和優(yōu)選工作,設(shè)計(jì)方案技術(shù)經(jīng)濟(jì)性比較正在成為影響暖通空調(diào)設(shè)計(jì)質(zhì)量和效率的一項(xiàng)重要工作。如何對(duì)暖通空調(diào)設(shè)計(jì)方案進(jìn)行科學(xué)的比較和優(yōu)選,是暖通空調(diào)設(shè)計(jì)人員在實(shí)際設(shè)計(jì)工作中經(jīng)常遇到的一個(gè)重要技術(shù)難題。1.4空調(diào)的發(fā)展和前景1.4.1變頻空調(diào)的發(fā)展變頻空調(diào)是目前空調(diào)消費(fèi)的流行趨勢(shì)。它與一般空調(diào)比,有著高性能運(yùn)轉(zhuǎn)、舒適靜音。節(jié)能環(huán)保、能耗低的顯著特點(diǎn),它的出現(xiàn)改善了人們的生活質(zhì)量。日本作為變頻空調(diào)強(qiáng)國(guó),從20世紀(jì)80年代初開(kāi)始到現(xiàn)在,變頻空調(diào)已占其空調(diào)市場(chǎng)的90%左右。變頻空調(diào)在我國(guó)發(fā)展速度相當(dāng)快,不到8年時(shí)間就達(dá)到與日本先進(jìn)水平同步。進(jìn)入2000年,國(guó)內(nèi)個(gè)別企業(yè)將直流變頻技術(shù)與PAM控制技術(shù)結(jié)合應(yīng)用,使空調(diào)完全進(jìn)入變頻空調(diào)的最高領(lǐng)域。它不僅使直流變頻壓縮機(jī)的優(yōu)越性能充分發(fā)揮,更能利用數(shù)碼特點(diǎn),準(zhǔn)確提高能效,達(dá)到節(jié)能51%的目的。1.4.2無(wú)氟空調(diào)的發(fā)展臭氧層破壞是當(dāng)前全球面臨的重大的環(huán)境問(wèn)題之一,由于以前空調(diào)業(yè)所采用的傳統(tǒng)制冷劑對(duì)臭氧層有破壞作用及產(chǎn)生溫室效應(yīng),對(duì)大氣造成破壞,因而無(wú)氟空調(diào)是眾所期待的產(chǎn)品。近年來(lái)以海爾空調(diào)為代表的無(wú)氟空調(diào)的出現(xiàn),標(biāo)志著無(wú)氟空調(diào)時(shí)代的來(lái)臨。1.4.3舒適性空調(diào)的發(fā)展健康是空調(diào)業(yè)發(fā)展的主題之一。以前的空調(diào)采用了多種健康技術(shù),如負(fù)離子、離子集塵、多元光觸媒等,這些技術(shù)的運(yùn)用使空調(diào)產(chǎn)品的健康性能得到了極大提升。海爾空調(diào)把負(fù)離子、離子集塵、多元光觸媒、雙向換新風(fēng)、健康除濕等領(lǐng)先技術(shù)在內(nèi)的高科技手段組合起來(lái)使用,發(fā)揮了巨大的威力,而未來(lái)空調(diào)進(jìn)步的一個(gè)方向也就是對(duì)各種技術(shù)的靈活使用??照{(diào)氣流的舒適度是健康空調(diào)的另一個(gè)標(biāo)準(zhǔn)。傳統(tǒng)空調(diào)的送風(fēng)方式簡(jiǎn)單直吹人體,易引起傷風(fēng)、感冒、頭痛、關(guān)節(jié)痛等不舒適狀態(tài),因此新近推出的風(fēng)可以從周?chē)h(huán)繞,而不是對(duì)人直吹,通過(guò)改善空調(diào)送風(fēng)的氣流分布,令人感覺(jué)更舒適的空調(diào)——環(huán)繞立體送風(fēng)、三維立體風(fēng)健康空調(diào)成了熱銷(xiāo)產(chǎn)品也就不足為奇了。1.4.4一拖多空調(diào)器的發(fā)展從一個(gè)側(cè)面反映了我國(guó)居民居住環(huán)境的巨大變化,也為自身發(fā)展指明了方向。1993年以前,中國(guó)空調(diào)市場(chǎng)主要以一拖一為主,1993年海爾推出一拖二空調(diào)后,率先將空調(diào)業(yè)引入了一拖多時(shí)代。目前海爾一拖多空調(diào)產(chǎn)量突破了百萬(wàn)臺(tái)足以證明其市場(chǎng)消費(fèi)能力。海爾MRV網(wǎng)絡(luò)變頻一拖多中央空調(diào)的出現(xiàn)以及眾多廠(chǎng)家的家用中央空調(diào)產(chǎn)品使得家庭中央空調(diào)迅速普及。1.4.5其它空調(diào)新技術(shù)的發(fā)展1)HEPA酶技術(shù)HEPA酶殺菌技術(shù),對(duì)于0.3微米以上的粉塵吸附率可達(dá)99.9
%,對(duì)結(jié)核菌、大腸菌等有害細(xì)菌具有高效殺菌能力,對(duì)霉菌的生長(zhǎng)也有很強(qiáng)的抑制作用。2)冷觸媒技術(shù)冷觸媒這一技術(shù)采用日本專(zhuān)利,是一種低溫低吸附的材料,根據(jù)吸附--催化原理,在常溫下就能對(duì)甲醛等有害物質(zhì)邊吸附邊分解成二氧化碳和水,這種觸媒不需要再生,不需更換,使用壽命長(zhǎng)達(dá)十年以上。3)體感溫度控制技術(shù)智能裝在遙控器上的感溫元件,感知室內(nèi)人們活動(dòng)范圍的溫度,并將信息發(fā)射到主機(jī)接收器上,使主機(jī)隨時(shí)調(diào)整運(yùn)行狀態(tài),實(shí)現(xiàn)真正的體感溫度控制自動(dòng)化。4)人感控制技術(shù)人感控制技術(shù)利用雙紅外感應(yīng)器控測(cè)人的方位,自動(dòng)調(diào)節(jié)送風(fēng)方向(左送風(fēng)、中送風(fēng)、右送風(fēng)或全方位送風(fēng)),風(fēng)隨人行。5)PTC電輔助加熱技術(shù)PTC電輔助加熱技術(shù),可在超低溫條件下迅速制熱,效力強(qiáng)勁,安全可靠,可長(zhǎng)期使用??傊?,伴隨著科技和社會(huì)的進(jìn)步,節(jié)能、環(huán)保、健康、智能控制已成為空調(diào)發(fā)展的大趨勢(shì)。2原始資料深圳某實(shí)業(yè)有限公司辦公樓,地處廣東省深圳市。深圳東鄰大亞彎,南臨香港新界,面積2020平方公里,地勢(shì)南高北底,屬亞熱帶氣候,風(fēng)清宜人,降水豐富。2.1氣象參數(shù)深圳市室外氣象參數(shù)臺(tái)站位置:北緯23?30?,東經(jīng)113?80?,海拔92.2m大氣壓力:夏季100.34Kpa,冬季101.76Kpa空調(diào)溫度:夏季33℃,冬季6℃相對(duì)濕度:夏季79%,冬季72%室外計(jì)算日平均溫度:31.10℃室外平均風(fēng)速:夏季2.1m/s,冬季3m/s2.2建筑概況及工況設(shè)定深圳某實(shí)業(yè)有限公司辦公樓由商務(wù)辦公、會(huì)議、培訓(xùn)等功能組成的綜合樓,采用風(fēng)機(jī)盤(pán)管加新風(fēng)系統(tǒng),這各層的布局基本相同。地上六層,一層高4.2m,二—六層高3.6m,總的建筑面積為640m2。整座大樓的餐廳、辦公、會(huì)議等設(shè)半集中式的中央空調(diào)系統(tǒng),并保持室內(nèi)空氣舒適新鮮。建筑面積為3535m2??照{(diào)設(shè)計(jì)面積為3000m2。該建筑物相關(guān)資料如下:(1)屋面保溫材料為水泥膨脹珍珠巖50mm,卷材防水層5mm,水泥沙漿20mm,鋼筋混凝土35mm,內(nèi)粉刷20mm,通風(fēng)層200mm。(2)外墻外墻為厚度為240mm的磚墻,墻外表面為水泥砂漿20mm,墻為厚為70mm的石膏板保溫層,白灰內(nèi)粉刷20mm。(3)外窗雙層鋁合金窗,玻璃為5mm厚的透明普通玻璃,內(nèi)有白色簾(淺色)作為內(nèi)遮陽(yáng),窗高1.8m。(4)人數(shù)人員數(shù)的確定是根據(jù)各房間的使用功能及使用單位提出的要求確定的。(5)照明、設(shè)備由建筑電氣專(zhuān)業(yè)提供,照明設(shè)備為暗裝熒光燈,鎮(zhèn)流器設(shè)置在頂棚內(nèi),熒光燈罩無(wú)通風(fēng)孔,功率為30w/m2。設(shè)備負(fù)荷為40w/m2。(6)空調(diào)使用時(shí)間辦公樓空調(diào)每天使用10小時(shí),即8:00~18:00。(7)動(dòng)力與能源資料a.動(dòng)力:工業(yè)動(dòng)力電380V-50Hz;b.能源:由自備空調(diào)機(jī)房供給。2.3初步方案辦公樓的外圍護(hù)結(jié)構(gòu)多為鋼筋混凝土的框架結(jié)構(gòu),采用自重的輕型墻體材料作為外圍護(hù)結(jié)構(gòu)。初步設(shè)定此辦公樓采用風(fēng)機(jī)盤(pán)管加新風(fēng)系統(tǒng),分成兩個(gè)區(qū)(南區(qū)和北區(qū))。因?yàn)檗k公室是間歇性使用,白天使用,晚上關(guān)閉,人員分布較平均,同時(shí)各房間冷熱負(fù)荷并不相同需要進(jìn)行個(gè)別的調(diào)節(jié),導(dǎo)致熱濕比不同,所以全空氣系統(tǒng)并不適合。每層設(shè)有新風(fēng)機(jī)組,可以由同層的新風(fēng)機(jī)組送入室內(nèi),和風(fēng)機(jī)盤(pán)管一起滿(mǎn)足室內(nèi)的冷熱負(fù)荷。本系統(tǒng)管線(xiàn)不復(fù)雜,施工方便,夏季空調(diào)和冬季供暖同用一套系統(tǒng),無(wú)論從經(jīng)濟(jì)、使用壽命,還是從美觀、清潔的角度講,該系統(tǒng)都很符合建筑用途的要求。二~六層辦公室風(fēng)機(jī)盤(pán)管加新風(fēng)系統(tǒng);廁所設(shè)置排風(fēng)扇,保持廁所的相對(duì)負(fù)壓,通過(guò)其他房間滲透補(bǔ)充廁所風(fēng)量,再通過(guò)廁所風(fēng)機(jī)排出,使廁所異味不能擴(kuò)散至其他房間。正壓控制的問(wèn)題,為防止外部空氣流入空調(diào)房間,設(shè)定保持室內(nèi)5~10Pa正壓,送風(fēng)量大于排風(fēng)量時(shí),室內(nèi)將保持正壓。方案中的冷熱源初選為風(fēng)冷熱泵型冷熱水機(jī)組,最主要的決定因素是對(duì)象的使用功能和四周環(huán)境。辦公樓無(wú)生活熱水的需求,因而冬季的熱負(fù)荷較小,加上冬季室外環(huán)境也不太惡劣,使用熱泵完全可以滿(mǎn)足要求,沒(méi)有單獨(dú)設(shè)置熱源的必要。3空調(diào)系統(tǒng)的負(fù)荷計(jì)算為連續(xù)保持空調(diào)房間恒溫、恒濕在某一時(shí)刻需向房間供應(yīng)的冷量稱(chēng)為冷負(fù)荷;為維持室內(nèi)相對(duì)濕度恒定需從房間去除的濕量成為濕負(fù)荷。房間冷、濕負(fù)荷也是確定空調(diào)系統(tǒng)送風(fēng)量及各種設(shè)備容量的依據(jù)??照{(diào)房間或區(qū)域的夏季計(jì)算得熱量,應(yīng)根據(jù)下列各項(xiàng)確定:1.通過(guò)維護(hù)結(jié)構(gòu)傳入的熱量;2.透過(guò)外窗進(jìn)入的太陽(yáng)輻射熱量;3.人體散熱量;4.照明散熱量;5.設(shè)備、器具、管道及其他內(nèi)部熱源的散熱量;6.食品或物料的散熱量;7.滲透空氣帶入的熱量;8.伴隨各種散濕過(guò)程產(chǎn)生的潛熱量。空調(diào)房間或者區(qū)域的夏季冷負(fù)荷,應(yīng)根據(jù)各項(xiàng)得熱量的種類(lèi)性質(zhì)以及空調(diào)房間或區(qū)域的蓄熱特性進(jìn)行分別計(jì)算。通過(guò)維護(hù)結(jié)構(gòu)進(jìn)入的不穩(wěn)定傳熱量、透過(guò)外窗進(jìn)入的太陽(yáng)輻射熱量、人體散熱量以及非全天使用的設(shè)備、照明燈具的散熱量等形成的冷負(fù)荷,宜按不穩(wěn)定傳熱方法計(jì)算確定,此空調(diào)工程設(shè)計(jì)采用冷負(fù)荷系數(shù)??照{(diào)房間或區(qū)域的夏季計(jì)算散濕量,應(yīng)根據(jù)下列各項(xiàng)確定1.人體散濕量;2.滲透空氣帶入的濕量;3.化學(xué)反應(yīng)過(guò)程的散濕量;4.各種潮濕表面、液面或液流的散濕量;5.食品或氣體物料的散濕量;6.設(shè)備散濕量;;7.通過(guò)維護(hù)結(jié)構(gòu)構(gòu)的散濕量量。確定散濕量時(shí),應(yīng)應(yīng)根據(jù)散濕濕源的種類(lèi)類(lèi),分別選選用適宜的的群集系數(shù)數(shù)、負(fù)荷系系數(shù)和同時(shí)時(shí)使用系數(shù)數(shù),有條件件時(shí),應(yīng)采采用實(shí)測(cè)數(shù)數(shù)值。一般般民用建筑筑不計(jì)算上上述第2項(xiàng)和第7項(xiàng)。3.1室內(nèi)空空調(diào)設(shè)計(jì)參參數(shù)在進(jìn)行空調(diào)設(shè)計(jì)計(jì)時(shí),無(wú)論論是舒適性性空調(diào)還是是工藝性空空調(diào)的設(shè)計(jì)計(jì),都應(yīng)以以人體的舒舒適感為確確定室內(nèi)設(shè)設(shè)計(jì)條件的的最基本要要求。此外外還應(yīng)考慮慮經(jīng)濟(jì)方面面的因素。在在具體確定定室內(nèi)設(shè)計(jì)計(jì)參數(shù)時(shí),應(yīng)應(yīng)根據(jù)不同同建筑及房房間使用或或業(yè)主的使使用標(biāo)準(zhǔn)要要求,在所所給范圍內(nèi)內(nèi)靈活選取取。查《暖暖通空調(diào)》[1]表2-2得辦公樓室內(nèi)設(shè)計(jì)參數(shù)。表3—1辦公樓室室內(nèi)設(shè)計(jì)參參數(shù)名稱(chēng)季節(jié)溫度(℃)濕度(%)人員密度照明標(biāo)準(zhǔn)設(shè)備標(biāo)準(zhǔn)展廳夏季25650.3400冬季1850接待廳夏季25650.3205冬季1850電教室夏季25650.3205冬季1850培訓(xùn)室夏季25650.3205冬季1850咖啡廳夏季25550.4100冬季2050貴賓室夏季25550.2200冬季2050經(jīng)理室夏季25550.11113冬季2045辦公室夏季25550.11113冬季2045會(huì)議室夏季25650.3205冬季1850公司分部夏季25550.21113冬季2045廠(chǎng)部中心夏季25550.21113冬季2045商務(wù)中心夏季25550.21113冬季2045消防控制室夏季25550.21113冬季20453.2冷負(fù)荷荷計(jì)算3.2.1夏夏季冷負(fù)荷荷計(jì)算依據(jù)據(jù)夏季空調(diào)冷負(fù)荷荷采用逐時(shí)時(shí)冷負(fù)荷系系數(shù)法(1)圍護(hù)結(jié)構(gòu)瞬變傳傳熱形成冷冷負(fù)荷的計(jì)計(jì)算方法在日射和室外氣氣溫綜合作作用下,外外墻和屋面面瞬變傳熱熱引起的逐逐時(shí)冷負(fù)荷荷可按下式式計(jì)算:(3-2--1)式中——外墻和和屋面的傳傳熱引起的的逐時(shí)冷負(fù)負(fù)荷,;———外墻和和屋面的面面積,;td——地方溫溫差修正值值——外墻和屋面面的傳熱系系數(shù),;——室內(nèi)計(jì)計(jì)算溫度,;———外墻和和屋面冷負(fù)負(fù)荷計(jì)算溫溫度的逐時(shí)時(shí)值,。(2)內(nèi)維護(hù)結(jié)構(gòu)冷負(fù)負(fù)荷當(dāng)鄰室為通風(fēng)良良好的非空空調(diào)房間時(shí)時(shí),通過(guò)內(nèi)內(nèi)墻和樓板板的溫差傳傳熱而產(chǎn)生生的冷負(fù)荷荷可按上式式計(jì)算。當(dāng)當(dāng)鄰室有一一定的發(fā)熱熱量時(shí),通通過(guò)空調(diào)房房間隔墻、樓樓板、內(nèi)窗窗、內(nèi)門(mén)等等內(nèi)維護(hù)結(jié)結(jié)構(gòu)的溫差差傳熱而產(chǎn)產(chǎn)生的冷負(fù)負(fù)荷,可視視作穩(wěn)定傳傳熱,不隨隨時(shí)間而變變化,可按按下式計(jì)算算:(3-2--2)式中———內(nèi)維護(hù)護(hù)結(jié)構(gòu)(如如內(nèi)墻、樓樓板等)的的傳熱系數(shù)數(shù),;———內(nèi)維護(hù)護(hù)結(jié)構(gòu)的面面積,;———夏季空空調(diào)室外計(jì)計(jì)算日平均均溫度,;;——附加溫升。(3)外玻璃窗瞬變傳傳熱下的冷冷負(fù)荷在室室內(nèi)外溫差差作用下,通通過(guò)外玻璃璃窗瞬變傳傳熱引起的的冷負(fù)荷可可按下式計(jì)計(jì)算:(3-2--3)式中ccw——窗框修修正系數(shù);;——外玻璃窗瞬瞬變傳熱引引起的冷負(fù)負(fù)荷,W;———窗口面面積,;———外玻璃璃窗傳熱系系數(shù),;———外玻璃璃窗的冷負(fù)負(fù)荷溫度的的逐時(shí)值,;ttd——地點(diǎn)修修正系數(shù)。(4)透過(guò)玻璃窗的日日射得熱引引起的冷負(fù)負(fù)荷的計(jì)算算方法透過(guò)玻璃窗進(jìn)入入室內(nèi)的日日射得熱引引起的逐時(shí)時(shí)冷負(fù)荷按按下式計(jì)算算:=CACDC(3-2--4)式中A——窗口面面積,;C——有效面面積系數(shù)C——窗玻璃冷負(fù)負(fù)荷系數(shù),無(wú)無(wú)因次。(5)設(shè)備散熱形成的的冷負(fù)荷計(jì)計(jì)算設(shè)備和用具顯熱熱形成的冷冷負(fù)荷按下下式計(jì)算::=C(3-2--5)式中)——設(shè)設(shè)備和用具具顯熱形成成的冷負(fù)荷荷,W;——設(shè)備和和用具的實(shí)實(shí)際顯熱散散熱量,WW;C——設(shè)備和用具具顯熱散熱熱冷負(fù)荷系系數(shù),如果果空調(diào)系統(tǒng)統(tǒng)不連續(xù)運(yùn)運(yùn)行,則CLQ=1.0電子設(shè)備:(3-2--6)式中——電動(dòng)設(shè)設(shè)備的安裝裝功率,kkW;——內(nèi)圍護(hù)護(hù)結(jié)構(gòu)的傳傳熱系數(shù),;——電動(dòng)機(jī)機(jī)效率;——利用系系數(shù),是電電動(dòng)機(jī)最大大實(shí)效功率率與安裝功功率之比,一一般可取0.7~0.9,可用于于反映安裝裝功率的利利用程度;;——電動(dòng)機(jī)機(jī)負(fù)荷系數(shù)數(shù),定義為為電動(dòng)機(jī)每每小時(shí)平均均實(shí)耗功率率與機(jī)器設(shè)設(shè)計(jì)最大實(shí)耗功率率之比,對(duì)對(duì)計(jì)算機(jī)可可取1.0,一般儀儀表取0.5~0.9;——同時(shí)使使用系數(shù),定定義為室內(nèi)內(nèi)電動(dòng)機(jī)同同時(shí)使用的的安裝功率率與總安裝裝功率之比比,一般取取0.5~0.8。(6)照明散熱形成成的冷負(fù)荷荷計(jì)算當(dāng)電電壓一定時(shí)時(shí),室內(nèi)照照明散熱量量是不隨時(shí)時(shí)間變化的的穩(wěn)定散熱熱量,但是是照明散熱熱方式仍以以對(duì)流和輻輻射兩種方方式進(jìn)行散散熱,因此此照明散熱熱形式的冷冷負(fù)荷計(jì)算算仍采用相相同的冷負(fù)負(fù)荷系數(shù)。(3-2--7)式中———燈具散熱熱形成的冷冷負(fù)荷,WW;——照明燈具所所需功率,kW;———鎮(zhèn)流器器消耗功率率系數(shù),當(dāng)當(dāng)明裝熒光光燈的鎮(zhèn)流流器裝在空空調(diào)房間內(nèi)內(nèi)時(shí),取=1.2;當(dāng)暗裝裝熒光燈鎮(zhèn)鎮(zhèn)流器裝高高在頂棚時(shí)時(shí),可取==1.0;———燈罩隔隔熱系數(shù),當(dāng)當(dāng)熒光燈罩罩上部穿有有小孔(下部為玻玻璃板),可利用用自然通風(fēng)風(fēng)散熱于頂頂棚內(nèi)時(shí),取取=0.5~0.6;而熒光光燈罩無(wú)通通風(fēng)孔者=0..6~0.8;———照明散熱熱冷負(fù)荷系系數(shù)。(7)人體散熱形成的的冷負(fù)荷計(jì)計(jì)算室內(nèi)人員顯熱散散熱形成的的冷負(fù)荷,其其計(jì)算公式式為:(3-2--8)式中———人體顯顯熱散熱形形成的冷負(fù)負(fù)荷,W;———不同室室溫和勞動(dòng)動(dòng)性質(zhì)成年年男子顯熱熱散熱量,W;———室內(nèi)全全部人數(shù);;——群集系數(shù);;——人體顯熱散散熱冷負(fù)荷荷系數(shù)。(8)夏季空調(diào)新風(fēng)冷冷負(fù)荷Qc.o=Moo(ho—hR)(3-2--9)式中Qc.o———夏季新風(fēng)風(fēng)冷負(fù)荷,kw;Mo——新風(fēng)量量,kg//s;ho——室外空空氣的焓值值,kJ//kg;hR——室內(nèi)空空氣的焓值值,kJ//kg;3.2.2冷冷負(fù)荷的計(jì)計(jì)算過(guò)程及及結(jié)果以二樓左側(cè)辦公公室202為例1.南外墻冷負(fù)荷由《暖通空調(diào)》[[1]附錄錄表2-4查得Ⅱ型外墻冷冷負(fù)荷計(jì)算算溫度,由由公式(3-2--1)計(jì)算,將將其逐時(shí)值值及計(jì)算結(jié)結(jié)果列入表表3-2中。計(jì)算算公式同上上。表3-2南外外墻冷負(fù)荷荷時(shí)間8:009:0010:0011:0012:0013:0014:0015:0016:0017:0018:00tc(t)34.634.233.933.533.232.932.832.933.133.433.9td1.02kα1kβ0.94t,c(t)33.4833.1132.8232.4532.1731.8831.7931.8832.0732.3532.82tR25△t8.488.117.827.457.176.886.796.887.077.357.82K1.26A12.6134.67128.7124.23118.26113.78109.30107.81109.30112.29116.76124.23表3-3東外外墻冷負(fù)荷荷時(shí)間8:009:0010:0011:0012:0013:0014:0015:0016:0017:0018:00tc(t)36.035.535.235.035.035.235.636.136.637.137.5td1.02kα1kβ0.94t,c(t)34.8034.3334.0533.8633.8634.0534.4234.8935.3635.8336.21tR25△t9.809.339.058.868.869.059.429.8910.3610.8311.21K1.26A6.369.6766.7164.9363.7563.7564.9367.3070.2673.2276.1878.55辦公室內(nèi)墻,通通過(guò)溫差傳傳熱產(chǎn)生冷冷負(fù)荷,可可視作穩(wěn)態(tài)態(tài)傳熱,不不隨時(shí)間變變化。查《實(shí)實(shí)用供熱空空調(diào)設(shè)計(jì)手手冊(cè)》[22]表11.55-1得鋼筋混混凝土樓板板的穩(wěn)態(tài)傳傳熱系數(shù)為為2.733W/m2℃。由于其其地下室為為制冷機(jī)房房,產(chǎn)生一一定的熱量量,由[4]表2-10查得附加升升溫△t=2℃。由內(nèi)墻冷冷負(fù)荷計(jì)算算公式(3-2--2)計(jì)算其其冷負(fù)荷。=2..31(7.5++6)4(33+44-26)=12447.400W2.南外窗瞬瞬時(shí)傳熱冷冷負(fù)荷根據(jù)玻璃在=88.7w//()和=18..6w/(()條件下,由由[4]附錄2-8查得=2..93ww/()。在由附附錄2-9查得玻璃璃窗傳熱系系數(shù)的修正正值,對(duì)金金屬雙層窗窗應(yīng)乘1.2的修正系系數(shù)。由附附錄2-10查得玻璃璃窗冷負(fù)荷荷計(jì)算溫度度,根據(jù)公公式(3-2--3)計(jì)算,計(jì)計(jì)算結(jié)果列列入表2-4中。表3-4南外外窗瞬時(shí)傳傳熱冷負(fù)荷荷時(shí)間8:009:0010:0011:0012:0013:0014:0015:0016:0017:0018:00tc(τ)26.927.929.029.930.831.531.932.232.232.031.6td1t'c(τ)25.927.928.028.929.830.530.931.231.23130.6tR25.00△t0.92.933.94.85.55.96.26.265.6kw2.94Aw9Qc(t)23.8176.7379.38103.19127.01145.53156.11164.05164.05158.76148.18由《暖通空調(diào)》[[1]附錄2-15種查得雙雙層鋼窗有有效面積系系數(shù)=0..75,故鋼窗窗的有效面面積Aw=9××0.755=6.775。由[1]附錄2--13查得遮擋擋系數(shù)=00.78,由[1]]附錄2-14中查得遮遮陽(yáng)系數(shù)==0.5,于是綜綜合遮陽(yáng)系系數(shù)=0..78×0.5==0.399。再由[11]附錄2-12中查得緯緯度23.330時(shí),南向向日曬得熱熱因數(shù)最大大值Dj..max==174..00。因深圳圳地區(qū)北緯緯23.330,屬于北北區(qū),故由由[1]附錄2-17查得北區(qū)區(qū)由內(nèi)遮陽(yáng)陽(yáng)的玻璃窗窗冷負(fù)荷系系數(shù)逐時(shí)值值。用公式(3-22-4)計(jì)算逐時(shí)時(shí)進(jìn)入玻璃璃窗日射得得熱引起的的冷負(fù)荷,列列入表3-5中表3-5南外外窗透射得得熱引起的的冷負(fù)荷時(shí)間8:009:0010:0011:0012:0013:0014:0015:0016:0017:0018:00CLQ0.260.400.580.840.800.620.450.320.240.16Cc.s0.39Dj.max174.00Aw6.75Qc(t)119.09183.22265.67329.80384.77366.44283.99206.12146.58109.9373.293.燈光冷負(fù)負(fù)荷由于暗裝熒光燈燈,故鎮(zhèn)流流器消耗功功率系數(shù)n1取1.0。燈罩隔隔熱系數(shù)取取0.8。由[1]附錄2-22得照明散散熱冷負(fù)荷荷系數(shù),按按公式(3-2--6)計(jì)算,其其結(jié)果列入入表3-6中。表3-6燈光光冷負(fù)荷時(shí)間8:009:0010:0011:0012:0013:0014:0015:0016:0017:0018:00CLQ0.680.860.890.900.910.910.920.930.940.0.950.95n11.00n20.80N673.2Qc(t)366.22463.16479.32484.70490.09490.09495.48500.86506.25511.63511.634.人體冷負(fù)負(fù)荷由于辦公室屬極極輕勞動(dòng)。查[1]表2-13,當(dāng)室溫為25時(shí),每人散發(fā)的顯熱和潛熱量為65w和69w,由[1]表2-12查得群集系數(shù)為0.96,由《民用建筑空調(diào)設(shè)計(jì)》[3]表1.3-4查得辦公類(lèi)建筑室內(nèi)人數(shù)為0.2人/m2。由此算得此辦公室的人數(shù)為0.2×6×7.5≈9人。由[1]附錄2-23查得人體潛熱散熱冷負(fù)荷系數(shù)逐時(shí)值。按式(3-2-7)計(jì)算人體顯熱散熱逐時(shí)冷負(fù)荷,并列入表3-7中。人體潛熱引起的的冷負(fù)荷為為潛熱散熱熱乘以群集集系數(shù),計(jì)計(jì)算結(jié)果列列入表2-7中。表3-7人員員散熱引起起的冷負(fù)荷荷時(shí)間8:009:0010:0011:0012:0013:0014:0015:0016:0017:0018:00CLQ0.530.620.690.740.770.800.830.850.870.890.42qs65n9j0.96Q'c(t)297.65348.19387.50415.58432.43449.28466.13477.36488.59499.82235.87ql69Qc596.16合計(jì)893.81944.35983.661011.7441028.5991045.4441062.2991073.5221084.7551095.988832.03由于室內(nèi)保持正正壓,高于大氣氣壓力,所所以不需要要考慮由室室外空氣滲滲透所引起起的冷負(fù)荷荷。現(xiàn)將上上述各項(xiàng)計(jì)計(jì)算結(jié)果列列入表3-8中,并逐逐時(shí)相加,以以便求得室室內(nèi)冷負(fù)荷荷的最大值值。表2-8各項(xiàng)項(xiàng)逐時(shí)相加加冷負(fù)荷總總表時(shí)間8:009:0010:0011:0012:0013:0014:0015:0016:0017:0018:00南外窗傳23.8176.7379.38103.19127.01145.53156.11164.05164.05158.76148.18南外窗透119.09183.22265.67329.80384.77366.44283.99206.12146.58109.9373.29南外墻134.67128.70124.23118.26113.78109.30107.81109.30112.29116.76124.23東外墻69.6766.7164.9363.7563.7564.9367.3070.2673.2276.1878.55內(nèi)墻1247.4001247.4001247.4001247.4001247.4001247.4001247.4001247.4001247.4001247.4001247.400人員負(fù)荷893.81944.35983.661011.7441028.5991045.4441062.2991073.5221084.7551095.988832.03燈光負(fù)荷366.22463.16479.32484.70490.09490.09495.48500.86506.25511.63511.63總計(jì)2854.6773110.2773244.5993358.8443455.3993469.1333420.3883371.5113334.5443316.6443015.3115.夏季空調(diào)調(diào)新風(fēng)冷負(fù)負(fù)荷查[4]表11..1-6可知辦公公室人均新新風(fēng)量為20m3/h,由濕空氣氣焓濕圖查查得:室內(nèi)內(nèi)空氣焓值值為58.444kJ/kkg(tR=25℃,=65%%);室外空空氣焓值為為89.776kJ/kkg(to=33..0℃,ts=277.9℃).在10000.34PPa的焓濕圖圖上,已知知室外干球球溫度核、濕濕球溫度可可得出空氣氣的比容為為0.855m3/kg,則ma=20×433.2=00.04667kgg/s將已知條件與計(jì)計(jì)算條件代代入式中,則則有:=0.04677×(89.776-588.44)=1.7003kWW辦公室的夏季設(shè)設(shè)計(jì)負(fù)荷(不不考慮風(fēng)機(jī)機(jī)和管道的的溫升所引引起的冷負(fù)負(fù)荷)=11.7033+3.4455=55.1588kW其他房間計(jì)算方方法大致相相同,將其結(jié)果果列入表3-8表3-8辦公公樓夏季負(fù)負(fù)荷匯總表表房間編號(hào)計(jì)算面積計(jì)算人數(shù)房間面積指標(biāo)負(fù)荷最大值出現(xiàn)現(xiàn)的時(shí)刻HH新風(fēng)冷負(fù)荷冷負(fù)荷濕負(fù)荷m2個(gè)Wkg/hW/m2W10143.23040151.001492.9413:00257110243.23042301.001497.9216:00405910364.83059070.600891.1616:00473210464.83048581.001474.9717:00203010543.23039401.001491.2013:004059大廳南140.41580331.37357.229:004397大廳北74.41537931.089250.9810:00233020143.22025620.200359.3115:00170420243.22028620.200366.2516:00170420364.83059040.600891.1116:001033620464.82036430.300456.2210:00243420543.22025860.200359.869:001704大廳南53.281553180.49499.8115:001723大廳北74.41524960.689833.5516:00234930143.22041521.001496.1116:00375830243.22040861.001494.5817:00375830364.82072121.5021111.3017:00542930464.82052321.502180.749:00542930543.22041761.001496.6710:003550大廳南63.281563340.5867100.0916:002036大廳北74.41524960.689833.5516:00203640143.22030680.400671.0216:00316440243.22030830.400671.3710:00316440364.83056320.600886.919:00949340464.82037110.400657.2710:00486840543.22030920.400671.5716:003164大廳南63.281563340.5867100.0916:002036大廳北74.41524960.689833.5516:00234950143.24027570.200363.8210:00438150243.23037140.200385.979:00219150364.84051320.300479.2016:00632850464.83036430.300456.2216:00328650543.24027810.200364.3816:004381大廳南63.281563340.5867100.0917:002036大廳北74.41524960.689833.5517:00203660143.22045001.0014104.1715:00375860243.22046901.0014108.5616:00375860364.82076001.5021117.2816:00542960464.82059001.502191.0516:00542960543.22043251.0014100.1216:003758大廳南53.381551450.52196.3817:001566大廳北74.41560210.726180.9317:002036合計(jì)243993018628930.25376.3916:00150737最大冷負(fù)荷出現(xiàn)現(xiàn)在下午四四點(diǎn)鐘3.3熱負(fù)荷的的計(jì)算3.3.1冬季季熱負(fù)荷的的計(jì)算依據(jù)據(jù)冬季室內(nèi)耗熱量量主要包括括以下兩個(gè)個(gè)方面:1.維護(hù)結(jié)構(gòu)基本本耗熱量及及附加耗熱熱量;2.外門(mén)、外窗的的冷風(fēng)滲透透耗熱量;;冬季室內(nèi)得熱量量主要來(lái)自自以下三個(gè)個(gè)方面:1.人體散熱量;;2.照明燈具散熱熱量;3.設(shè)備散熱量。冬季室內(nèi)散濕量量主要來(lái)自自人體散濕濕量,熱負(fù)負(fù)荷的計(jì)算算采用穩(wěn)態(tài)態(tài)計(jì)算法負(fù)圍護(hù)結(jié)構(gòu)的耗熱熱量包括基基本耗熱量量和附加耗耗熱量?jī)刹坎糠?;圍護(hù)結(jié)構(gòu)的基本本耗熱量::Qj=Aj·Kj··(tR-to.ww)·α(3-3--1)式中Qj———j部分圍護(hù)護(hù)結(jié)構(gòu)的基基本耗熱量量,W;Aj——j部分圍護(hù)護(hù)結(jié)構(gòu)的表表面積,mm2;Kj——j部分圍護(hù)護(hù)結(jié)構(gòu)的傳傳熱系數(shù),W/(m2·℃);tR——冬季室室內(nèi)計(jì)算溫溫度,℃;to.w——冬季室室外空氣計(jì)計(jì)算溫度,℃;α——圍護(hù)結(jié)構(gòu)構(gòu)的溫差修修正系數(shù),見(jiàn)見(jiàn)[1]第13頁(yè),表2-4;(1)朝向附附加耗熱量量:朝向附加耗熱量量是考慮建建筑物受太太陽(yáng)照射影影響而對(duì)維維護(hù)結(jié)構(gòu)基基本耗熱量量的修正。不不同朝向的的維護(hù)結(jié)構(gòu)構(gòu)的修正率率見(jiàn)表3-9。表3-9圍護(hù)護(hù)結(jié)構(gòu)的朝朝向修正率率朝向修正率北、東北、西北北朝向0東、西朝向-5%東南、西南朝向向-10%~-155%南向-15%~-255%(2)高度度附加耗熱熱量:由于室內(nèi)溫度梯梯度的影響響,往往使使房間上部部的傳熱量量加大。因因此規(guī)定::當(dāng)房間凈凈高超過(guò)4米時(shí),每每增加1米,附加加率為2%,但最最大附加率率不超過(guò)15%。應(yīng)注注意:高度度附加率應(yīng)應(yīng)加在基本本耗熱量和和其他附加加耗熱量的的總和上。(3)風(fēng)力附附加耗熱量量:風(fēng)力附加耗熱量量是考慮室室外風(fēng)速變變化而對(duì)維維護(hù)結(jié)構(gòu)基基本耗熱量量的修正。在計(jì)算基本耗熱量時(shí),外表面換熱系數(shù)是對(duì)應(yīng)風(fēng)速約為4m/s的計(jì)算值。我國(guó)大部分地區(qū)冬季平均風(fēng)速為2~3m/s。因此《規(guī)范》規(guī)定,一般情況下,不必考慮風(fēng)力附加。綜合(1)、(22)、(3)、(4)通過(guò)維護(hù)護(hù)結(jié)構(gòu)的總總耗熱量可可用下式綜綜合表示::=(1+XXg)××K×F×(tnn–tw’)×((1++Xchh+XXf)]其中:Xgg——高度附附加率,00≤Xg≤15%;Xch——朝向修修正率,見(jiàn)見(jiàn)表2-1;Xf——風(fēng)力附附加率,Xf≥0。透在風(fēng)力和熱壓造造成的室內(nèi)內(nèi)外壓差作作用下,室室外的冷空空氣通過(guò)門(mén)門(mén)、窗等縫縫隙滲入室室內(nèi),被加加熱后逸出出,此部分分耗熱量為為冷風(fēng)滲透透耗熱量。為防止外界環(huán)境境空氣進(jìn)入入空調(diào)房間間,干擾空空調(diào)房間內(nèi)內(nèi)溫濕度變變化而破壞壞室內(nèi)潔凈凈度,需要要在空調(diào)系系統(tǒng)中由一一定量的新新風(fēng)來(lái)保持持房間的正正壓。因此此,空調(diào)房房間冬季可可以不考慮慮冷風(fēng)滲透透耗熱量。故故,在此空空調(diào)設(shè)計(jì)設(shè)設(shè)計(jì)中忽略略此項(xiàng)。以202辦公室為為例,將計(jì)計(jì)算結(jié)果列列入下表::表3-10熱熱負(fù)荷計(jì)算算表圍護(hù)結(jié)構(gòu)傳熱系數(shù)室內(nèi)外的計(jì)算溫溫差溫差修正系數(shù)基本耗熱量耗熱量修正名稱(chēng)及方向面積(m2)w/(m2.kk)tR-to朝向修正率風(fēng)力附加修正值修正后的熱量高度附加南外墻21.60.62191254.452001305.340南外窗103.46191657.42001788.880西內(nèi)墻25.922.421911191.80011191.80地面122.40.47191200.03001200.030地面214.40.2319162.92800162.9280地面36.40.1219114.59200114.5920房間熱負(fù)荷(WW)2563.577其他房間計(jì)算結(jié)結(jié)果相同,計(jì)計(jì)算結(jié)果列列入下表::表3-11房房間熱負(fù)荷荷匯總表房間號(hào)100110021003100410051006100710081009熱負(fù)荷4702568886136602194180511290房間號(hào)101010112001200220032004200520062007熱負(fù)荷660296645025649802321183212640房間號(hào)200820093001300230033004300530063007熱負(fù)荷83033540315982088980187211910房間號(hào)300830094001400240034004400540064007熱負(fù)荷78135945017869802321183211910房間號(hào)400840095001500250035004500550065007熱負(fù)荷78135976517861447980183247170房間號(hào)500850095010501160016002600360046005熱負(fù)荷781359100095129332467339917872506房間號(hào)6006600760086009總熱負(fù)荷76439熱負(fù)荷22093851800857空氣調(diào)節(jié)系統(tǒng)方方案及設(shè)備備的選擇4系統(tǒng)方案論證(1)建筑特點(diǎn)辦公樓的外圍護(hù)護(hù)結(jié)構(gòu)多為為鋼筋混凝凝土的框架架結(jié)構(gòu),采用自重重的輕型墻墻體材料作作為外圍護(hù)護(hù)結(jié)構(gòu)。大大量采用玻玻璃幕墻,,采用大面面積單層玻玻璃幕墻加加鋁合金飾飾板作為高高層寫(xiě)字樓樓外圍護(hù)結(jié)結(jié)構(gòu)的主流流,其玻璃幕幕墻主要為為6mm或8mm厚度的的熱反射鍍鍍膜玻璃。辦辦公樓由吊吊頂或架空空地板形成成辦公自動(dòng)動(dòng)化機(jī)器和和通訊設(shè)備備的線(xiàn)性空空間,辦公公樓的凈高高為2.66m左右。(2)使用特點(diǎn)辦公樓的使用性性質(zhì)與時(shí)間間全樓大體體一致,所以整幢幢樓可選擇擇用同樣的的空調(diào)系統(tǒng)統(tǒng)和設(shè)備,,管理比較較方便。辦辦公樓一般般采用集中中或半集中中空調(diào)系統(tǒng)統(tǒng)。(3)辦公樓空調(diào)系系統(tǒng)注意事事項(xiàng)a.分區(qū)問(wèn)題:按按建筑物分分為內(nèi)區(qū)和和外區(qū),也可以按按朝向分或或根據(jù)房間間用途、標(biāo)標(biāo)高低、負(fù)荷變化化以及使用用時(shí)間等特特點(diǎn)劃分系系統(tǒng)。b.過(guò)度季節(jié)問(wèn)題題:過(guò)度季季節(jié)外區(qū)可可不用冷熱熱源,但內(nèi)區(qū)仍仍需要降溫溫,這時(shí)應(yīng)用用室外空氣氣直接進(jìn)入入內(nèi)區(qū)降溫溫,即節(jié)能又又簡(jiǎn)單;或考慮采采用一臺(tái)小小容量的制制冷機(jī)。c.加班問(wèn)題:個(gè)個(gè)別辦公樓樓或某層需需要節(jié)假日日加班,為此最好好不要設(shè)太太大的集中中空調(diào)系統(tǒng)統(tǒng)。d.特殊房間的個(gè)個(gè)別控制問(wèn)問(wèn)題:用風(fēng)風(fēng)機(jī)盤(pán)管系系統(tǒng)以便控控制。4.1方案比較較表4-1全空空氣系統(tǒng)與與空氣-水水系統(tǒng)方案案比較表[2]比較項(xiàng)目全空氣系統(tǒng)空氣-水系統(tǒng)設(shè)備布置與機(jī)房房空調(diào)與制冷設(shè)備備可以集中中布置在機(jī)機(jī)房機(jī)房面積較大層層高較高有時(shí)可以布置在在屋頂或安安設(shè)在車(chē)間間柱間平臺(tái)臺(tái)上只需要新風(fēng)空調(diào)調(diào)機(jī)房、機(jī)機(jī)房面積小小風(fēng)機(jī)盤(pán)管可以設(shè)設(shè)在空調(diào)機(jī)機(jī)房?jī)?nèi)分散布置、敷設(shè)設(shè)各種管線(xiàn)線(xiàn)較麻煩風(fēng)管系統(tǒng)空調(diào)送回風(fēng)管系系統(tǒng)復(fù)雜、布布置困難支風(fēng)管和風(fēng)口較較多時(shí)不易易均衡調(diào)節(jié)節(jié)風(fēng)量放室內(nèi)時(shí)不接送送、回風(fēng)管管當(dāng)和新風(fēng)系統(tǒng)聯(lián)聯(lián)合使用時(shí)時(shí),新風(fēng)管管較小節(jié)能與經(jīng)濟(jì)性可以根據(jù)室外氣氣象參數(shù)的的變化和室室內(nèi)負(fù)荷變變化實(shí)現(xiàn)全全年多工況況節(jié)能運(yùn)行行調(diào)節(jié),充充分利用室室外新風(fēng)減減少與避免免冷熱抵消消,減少冷冷凍機(jī)運(yùn)行行時(shí)間對(duì)熱濕負(fù)荷變化化不一致或或室內(nèi)參數(shù)數(shù)不同的多多房間不經(jīng)經(jīng)濟(jì)部分房間停止工工作不需空空調(diào)時(shí)整個(gè)個(gè)空調(diào)系統(tǒng)統(tǒng)仍需運(yùn)行行不經(jīng)濟(jì)靈活性大、節(jié)能能效果好,可可根據(jù)各室室負(fù)荷情況況自我調(diào)節(jié)節(jié)盤(pán)管冬夏兼用,內(nèi)內(nèi)避容易結(jié)結(jié)垢,降低低傳熱效率率無(wú)法實(shí)現(xiàn)全年多多工況節(jié)能能運(yùn)行使用壽命使用壽命長(zhǎng)使用壽命較長(zhǎng)安裝設(shè)備與風(fēng)管的安安裝工作量量大周期長(zhǎng)長(zhǎng)安裝投產(chǎn)較快,介介于集中式式空調(diào)系統(tǒng)統(tǒng)與單元式式空調(diào)器之之間維護(hù)運(yùn)行空調(diào)與制冷設(shè)備備集中安設(shè)設(shè)在機(jī)房便便于管理和和維護(hù)布置分散維護(hù)管管理不方便便,水系統(tǒng)統(tǒng)布置復(fù)雜雜、易漏水水溫濕度控制可以嚴(yán)格地控制制室內(nèi)溫度度和室內(nèi)相相對(duì)濕度對(duì)室內(nèi)溫度要求求嚴(yán)格時(shí)難難于滿(mǎn)足空氣過(guò)濾與凈化化可以采用初效、中中效和高效效過(guò)濾器,滿(mǎn)滿(mǎn)足室內(nèi)空空氣清潔度度的不同要要求,采用用噴水室時(shí)時(shí)水與空氣氣直接接觸觸易受污染染,須常換換水過(guò)濾性能差,室室內(nèi)清潔度度要求較高高時(shí)難于滿(mǎn)滿(mǎn)足消聲與隔振可以有效地采取取消防和隔隔振措施必須采用低噪聲聲風(fēng)機(jī)才能能保證室內(nèi)內(nèi)要求風(fēng)管互相串通空調(diào)房間之間有有風(fēng)管連通通,使各房房間互相污污染,當(dāng)發(fā)發(fā)生火災(zāi)時(shí)時(shí)會(huì)通過(guò)風(fēng)風(fēng)管迅速蔓蔓延各空調(diào)房間之間間不會(huì)互相相污染表3-2風(fēng)機(jī)機(jī)盤(pán)管+新風(fēng)系統(tǒng)統(tǒng)的特點(diǎn)表表[2]優(yōu)點(diǎn)1)布置靈活,可以以和集中處處理的新風(fēng)風(fēng)系統(tǒng)聯(lián)合合使用,也也可以單獨(dú)獨(dú)使用2)各空調(diào)房間互不不干擾,可可以獨(dú)立地地調(diào)節(jié)室溫溫,并可隨隨時(shí)根據(jù)需需要開(kāi)停機(jī)機(jī)組,節(jié)省運(yùn)行行費(fèi)用,靈靈活性大,節(jié)節(jié)能效果好好3)與集中式空調(diào)相相比不需回回風(fēng)管道,節(jié)節(jié)約建筑空空間4)機(jī)組部件多多為裝配式式、定型化化、規(guī)格化化程度高,便便于用戶(hù)選選擇和安裝裝5)只需新風(fēng)空空調(diào)機(jī)房,機(jī)機(jī)房面積小小6)使用季節(jié)長(zhǎng)長(zhǎng)7)各房間之間不會(huì)會(huì)互相污染染缺點(diǎn)1)對(duì)機(jī)組制作要求求高,則維維修工作量量很大2)機(jī)組剩余壓壓頭小室內(nèi)內(nèi)氣流分布布受限制3)分散布置敷敷設(shè)各中管管線(xiàn)較麻煩煩,維修管管理不方便便4)無(wú)法實(shí)現(xiàn)全全年多工況況節(jié)能運(yùn)行行調(diào)節(jié)5)水系統(tǒng)復(fù)雜雜,易漏水水6)過(guò)濾性能差適用性適用于旅館、公公寓、醫(yī)院院、辦公樓樓等高層多多層的建筑筑物中,需要增設(shè)空調(diào)的的小面積多多房間建筑筑室溫需要要進(jìn)行個(gè)別別調(diào)節(jié)的場(chǎng)場(chǎng)合表3-3風(fēng)機(jī)機(jī)盤(pán)管的新新風(fēng)供給方方式表[22]供給方式示意圖特點(diǎn)適用范圍房間縫隙自然滲滲入1)無(wú)規(guī)律滲透透風(fēng),室溫溫不均勻2)簡(jiǎn)單、方便便3)衛(wèi)生條件差差4)初投資與運(yùn)運(yùn)用費(fèi)用低低5)機(jī)組承擔(dān)新新風(fēng)負(fù)荷,長(zhǎng)長(zhǎng)時(shí)間在濕濕工況下工工作1)人少,無(wú)正正壓要求,清清潔度要求求不高的空空調(diào)房間2)要求節(jié)省投投資與運(yùn)行行費(fèi)用的房房間3)新風(fēng)系統(tǒng)布布置有困難難或舊有建建筑改造機(jī)組背面墻洞引引入新風(fēng)1)新風(fēng)口可調(diào)調(diào)節(jié),冬、夏夏季最小新新風(fēng)量;過(guò)過(guò)渡季大新新風(fēng)量2)隨新風(fēng)負(fù)荷荷變化,室室內(nèi)直接受受影響3)初投資與運(yùn)運(yùn)行費(fèi)節(jié)省省4)須作好防塵塵、防噪聲聲、防雨、防防凍措施5)機(jī)組長(zhǎng)時(shí)間間在濕工況況下工作同上房高為6m以下下的建筑物物單設(shè)新風(fēng)系統(tǒng),獨(dú)獨(dú)立供給室室內(nèi)1)單設(shè)新風(fēng)機(jī)機(jī)組,可隨隨室外氣象象變化進(jìn)行行調(diào)節(jié),保保證室內(nèi)濕濕度與新風(fēng)風(fēng)量要求2)投資大3)占有空間多多4)新風(fēng)口盡量量緊靠風(fēng)機(jī)機(jī)盤(pán)管,為為佳要求衛(wèi)生條件嚴(yán)嚴(yán)格和舒適適的房間,目目前最常采采用此方式式單設(shè)新風(fēng)系統(tǒng)供供給風(fēng)機(jī)盤(pán)盤(pán)管1)單設(shè)新風(fēng)機(jī)機(jī)組,可隨隨室外氣象象變化進(jìn)行行調(diào)節(jié),保保證室內(nèi)濕濕度與新風(fēng)風(fēng)量要求2)投資大3)新風(fēng)按至風(fēng)機(jī)盤(pán)盤(pán)管,與回回風(fēng)混合后后進(jìn)入室內(nèi)內(nèi),加大了了風(fēng)機(jī)風(fēng)量量,增加噪噪聲要求衛(wèi)生條件嚴(yán)嚴(yán)格的房間間,目前較較少采用此此種方式本設(shè)計(jì)為辦公樓樓的空調(diào)系系統(tǒng)設(shè)計(jì),系系統(tǒng)的選定定應(yīng)注意檔檔次和安全全的要求,按按負(fù)擔(dān)室內(nèi)內(nèi)空調(diào)負(fù)荷荷所用的介介質(zhì)來(lái)分類(lèi)類(lèi)可選擇四四種系統(tǒng)———全空氣氣系統(tǒng)、空空氣—水系統(tǒng)、全全水系統(tǒng)、冷冷劑系統(tǒng)。全全空氣系統(tǒng)統(tǒng)分一次回回風(fēng)式系統(tǒng)統(tǒng)和二次回回風(fēng)式系統(tǒng)統(tǒng),該系統(tǒng)統(tǒng)是全部由由處理過(guò)的的空氣負(fù)擔(dān)擔(dān)室內(nèi)空調(diào)調(diào)冷負(fù)荷和和濕負(fù)荷;;空氣—水系統(tǒng)分分為再熱系系統(tǒng)和誘導(dǎo)導(dǎo)器系統(tǒng)并并用、全新新風(fēng)系統(tǒng)和和風(fēng)機(jī)盤(pán)管管機(jī)組系統(tǒng)統(tǒng)并用;全全水系統(tǒng)即即為風(fēng)機(jī)盤(pán)盤(pán)管機(jī)組系系統(tǒng),全部部由水負(fù)擔(dān)擔(dān)室內(nèi)空調(diào)調(diào)負(fù)荷,在在注重室內(nèi)內(nèi)空氣品質(zhì)質(zhì)的現(xiàn)代化化建筑內(nèi)一一般不單獨(dú)獨(dú)采用,而而是與新風(fēng)風(fēng)系統(tǒng)聯(lián)合合運(yùn)用;冷冷劑系統(tǒng)分分單元式空空調(diào)器系統(tǒng)統(tǒng)、窗式空空調(diào)器系統(tǒng)統(tǒng)、分體式式空調(diào)器系系統(tǒng),它是是由制冷系系統(tǒng)蒸發(fā)器器直接放于于室內(nèi)消除除室內(nèi)的余余熱和余濕濕。對(duì)于較較大型公共共建筑,建建筑內(nèi)部的的空氣品質(zhì)質(zhì)級(jí)別要求求較高,全全水系統(tǒng)和和冷劑系統(tǒng)統(tǒng)只能消除除室內(nèi)的余余熱和余濕濕,不能起起到改善室室內(nèi)空氣品品質(zhì)的作用用,所以全全水系統(tǒng)和和冷劑系統(tǒng)統(tǒng)在本次的的建筑空調(diào)調(diào)設(shè)計(jì)時(shí)不不宜采用。終上所述,擬采采用風(fēng)機(jī)盤(pán)盤(pán)管加新風(fēng)風(fēng)系統(tǒng),風(fēng)風(fēng)機(jī)盤(pán)管的的新風(fēng)供給給方式用單單設(shè)新風(fēng)系系統(tǒng),獨(dú)立立供給室內(nèi)內(nèi)。4.2方案的確確定本辦公樓采用風(fēng)風(fēng)機(jī)盤(pán)管加加新風(fēng)系統(tǒng)統(tǒng),分成兩兩個(gè)區(qū)(南南區(qū)和北區(qū)區(qū))。因?yàn)闉檗k公室是是間歇性使使用,白天天使用,晚晚上關(guān)閉,人人員分布較較平均,同同時(shí)各房間間冷熱負(fù)荷荷并不相同同需要進(jìn)行行個(gè)別的調(diào)調(diào)節(jié),導(dǎo)致致熱濕比不不同,所以以全空氣系系統(tǒng)并不適適合。每層層設(shè)有新風(fēng)風(fēng)機(jī)組,可可以由同層層的新風(fēng)機(jī)機(jī)組送入室室內(nèi),和風(fēng)風(fēng)機(jī)盤(pán)管一一起滿(mǎn)足室室內(nèi)的冷熱熱負(fù)荷。風(fēng)機(jī)盤(pán)管空調(diào)方方式,這種種方式風(fēng)管管小,可以以降低房間間層高,但但維修工作作量大,如如果水管漏漏水或冷水水管保溫不不好而產(chǎn)生生凝結(jié)水,對(duì)對(duì)線(xiàn)槽內(nèi)的的電線(xiàn)或其其它接近樓樓地面的電電器設(shè)備是是一個(gè)威脅脅,因此要要求確保管管道安裝質(zhì)質(zhì)量。風(fēng)機(jī)機(jī)盤(pán)管加新新風(fēng)系統(tǒng)占占空間少,使使用也較靈靈活,但空空調(diào)設(shè)備產(chǎn)產(chǎn)生的振動(dòng)動(dòng)和噪音問(wèn)問(wèn)題需要采采取切實(shí)措措施予以解解決。對(duì)于于該系統(tǒng)所所存在的缺缺點(diǎn),可在在設(shè)計(jì)當(dāng)中中根據(jù)具體體的問(wèn)題予予以解決和和彌補(bǔ)。冷熱源由風(fēng)冷冷冷熱水機(jī)組組提供。夏夏季供水/回水溫度度為7/12℃,冬季供供水/回水溫度度為45//40℃。該工程程水系統(tǒng)采采用雙管制制、水平同同程式、垂垂直議異程程式、一次次泵定水量量系統(tǒng)。系系統(tǒng)新風(fēng)由由分層設(shè)置置的新風(fēng)機(jī)機(jī)組供給,風(fēng)風(fēng)機(jī)盤(pán)管只只承擔(dān)房間間冷負(fù)荷,新新風(fēng)負(fù)荷由由新風(fēng)機(jī)組組承擔(dān)。采采用該系統(tǒng)統(tǒng)的理由如如下:1.選擇雙管制水系系統(tǒng)的理由由:在風(fēng)機(jī)機(jī)盤(pán)管水系系統(tǒng)中,由由一條供水水管和一條條回水管構(gòu)構(gòu)成的水系系統(tǒng)稱(chēng)為雙雙管制水系系統(tǒng)。供水水管根據(jù)房房間負(fù)荷要要求向房間間提供冷凍凍水或熱水水。由于其其系統(tǒng)簡(jiǎn)單單,初投資資低,是目目前我國(guó)絕絕大多數(shù)高高層民用建建筑中采用用的空調(diào)水水系統(tǒng)方式式。其特點(diǎn)點(diǎn)如下:(1))該系統(tǒng)簡(jiǎn)簡(jiǎn)單明了,冬冬夏季轉(zhuǎn)換換分明,轉(zhuǎn)轉(zhuǎn)換閥既可可以手動(dòng)也也可以電動(dòng)動(dòng),管理起起來(lái)方便;;(2)該系統(tǒng)投投資節(jié)省,管管道、附件件及保溫材材料的初投投資也較少少,占用的的建筑空間間和建筑面面積都較少少,者也是是它能得到到廣泛應(yīng)用用的一個(gè)重重要理由;;(3)末端設(shè)備備為冷熱兩兩用的盤(pán)管管,其控制制也比較方方便,末端端設(shè)備的投投資和機(jī)房房的面積均均可減少。2.選用同程式系統(tǒng)統(tǒng)的原由::水力計(jì)算算時(shí)同程系系統(tǒng)各個(gè)環(huán)環(huán)路易于平平衡,水力力失調(diào)較輕輕,而且布布置管道妥妥當(dāng)時(shí)耗費(fèi)費(fèi)管材不多多。方案中的冷熱源源從開(kāi)始就就選擇為風(fēng)風(fēng)冷熱泵機(jī)機(jī)組,這是是由多方面面因素決定定的。最主要的決定因因素是對(duì)象象的使用功功能和四周周環(huán)境。辦辦公樓無(wú)生生活熱水的的需求,因因而冬季的的熱負(fù)荷較較小,加上上冬季室外外環(huán)境也不不太惡劣,使使用熱泵完完全可以滿(mǎn)滿(mǎn)足要求,沒(méi)沒(méi)有單獨(dú)設(shè)設(shè)置熱源的的必要。另一個(gè)考慮因素素與深圳地地區(qū)的能源源價(jià)格及政政策有關(guān)。如如果白天用用電高峰的的電價(jià)與晚晚間的低谷谷電價(jià)差距距更大的話(huà)話(huà),為辦公公樓空調(diào)這這種典型的的可以“移峰填谷”的場(chǎng)所添添加相應(yīng)的的蓄冷設(shè)備備將具有很很高的可行行性。這不不僅可以減減少運(yùn)行費(fèi)費(fèi),由于可可大幅降低低初期的冷冷熱源容量量,還能節(jié)節(jié)約不少初初投資。但但相關(guān)資料料中的統(tǒng)計(jì)計(jì)分析,由由于在深圳圳地區(qū)低谷谷電的價(jià)格格優(yōu)勢(shì)不明明顯,節(jié)省省的電費(fèi)無(wú)無(wú)法抵消其其增加設(shè)備備的初投資資,得出采采用蓄冷技技術(shù)不經(jīng)濟(jì)濟(jì)的結(jié)論。此外,建筑形式式對(duì)冷熱源源選擇的影影響也不能能忽視。由由于沒(méi)有地地下室水冷冷機(jī)房,同同時(shí)頂層有有較大空間間及專(zhuān)門(mén)的的空調(diào)水泵泵房,這種種建筑布局局完全是為為風(fēng)冷機(jī)組組安排的。最后還要考慮業(yè)業(yè)主的需求求。由于深深圳經(jīng)濟(jì)發(fā)發(fā)達(dá)的原因因,地價(jià)節(jié)節(jié)節(jié)上升,使使得建筑師師及業(yè)主對(duì)對(duì)于空調(diào)占占地特別重重視。如果果使用風(fēng)冷冷熱泵,不不僅可以省省去了與冷冷水機(jī)組及及其對(duì)應(yīng)的的冷卻塔及及冷卻水循循環(huán)泵的占占地,還能能充分利用用原本一般般閑置的屋屋面空間,因因而業(yè)主對(duì)對(duì)于辦公樓樓也偏向于于選擇風(fēng)冷冷熱泵作為為冷熱源。綜合以上方面因因素,在附附近無(wú)集中中熱水或蒸蒸汽源的情情況下,決決定選擇風(fēng)風(fēng)冷熱泵作作為冷熱源源。4.3.1風(fēng)風(fēng)機(jī)盤(pán)管機(jī)機(jī)組的結(jié)構(gòu)構(gòu)和工作原原理風(fēng)機(jī)盤(pán)管機(jī)組是是空調(diào)機(jī)組組的末端機(jī)機(jī)組之一,,就是將通通風(fēng)機(jī)、換換熱器及過(guò)過(guò)濾器等組組成一體的的空氣調(diào)節(jié)節(jié)設(shè)備。機(jī)機(jī)組一般分分為立式和和臥式兩種種,可以按室室內(nèi)安裝位位置選定,,同時(shí)根據(jù)據(jù)室內(nèi)裝修修要求可做做成明裝或或暗裝。風(fēng)機(jī)盤(pán)管管通常與冷冷水機(jī)組((夏)或熱水機(jī)機(jī)組(冬)組成一個(gè)個(gè)供冷或供供熱系統(tǒng)。風(fēng)風(fēng)機(jī)盤(pán)管是是分散安裝裝在每一個(gè)個(gè)需要空調(diào)調(diào)的房間內(nèi)內(nèi)(如賓館的的客房、醫(yī)醫(yī)院的病房房、寫(xiě)字樓樓的各寫(xiě)字字間等)。風(fēng)機(jī)盤(pán)管機(jī)組中中風(fēng)機(jī)不斷斷循環(huán)所在在房間內(nèi)的的空氣和新新風(fēng),使空空氣通過(guò)供供冷水或供供熱水的換換熱器被冷冷卻或加熱熱,以保持持房間內(nèi)溫溫度。在風(fēng)風(fēng)機(jī)吸風(fēng)口口外設(shè)有空空氣過(guò)濾器器,用以過(guò)過(guò)濾被吸入入空氣中的的塵埃,一一方面改善善房間的衛(wèi)衛(wèi)生條件,另另一方面也也保護(hù)了換換熱器不被被塵埃所堵堵塞。換熱熱器在夏季季可以除去去房間的濕濕氣,維持持房間的一一定相對(duì)濕濕度。換熱熱器表面的的凝結(jié)水滴滴入接水盤(pán)盤(pán)內(nèi),然后后不斷地被被排入下水水道中。由于本系統(tǒng)采用用風(fēng)機(jī)盤(pán)管+新風(fēng)系統(tǒng),有有獨(dú)立的新新風(fēng)系統(tǒng)供供給室內(nèi)新新風(fēng),即把把新風(fēng)處理理到室內(nèi)參參數(shù),不承承擔(dān)房間負(fù)負(fù)荷。這種種方案既提提高了該系系統(tǒng)的調(diào)節(jié)節(jié)和運(yùn)轉(zhuǎn)的的靈活性,且且進(jìn)入風(fēng)機(jī)機(jī)盤(pán)管的供供水溫度可可適當(dāng)提高高,水管結(jié)結(jié)露現(xiàn)象可可以得到改改善。機(jī)組由風(fēng)機(jī)、電電動(dòng)機(jī)、盤(pán)盤(pán)管、空氣氣過(guò)濾器、室室溫調(diào)節(jié)裝裝置及箱體體等組成(見(jiàn)圖4-1))。圖4-1風(fēng)機(jī)機(jī)盤(pán)管機(jī)組組構(gòu)造圖4.3.2風(fēng)風(fēng)機(jī)盤(pán)管的的系統(tǒng)設(shè)計(jì)計(jì)風(fēng)機(jī)盤(pán)盤(pán)管機(jī)組設(shè)設(shè)計(jì)的首要要任務(wù)實(shí)選選擇風(fēng)機(jī)盤(pán)盤(pán)管的形式式。風(fēng)機(jī)盤(pán)盤(pán)管的形式式有:臥式式明裝、臥臥式暗裝、立立式明裝、立立式暗裝等等。本辦公公樓選用臥臥式暗裝在在吊頂內(nèi),其其主要優(yōu)點(diǎn)點(diǎn)是不占用用房間的有有效空間,冷冷凍水的配配管與其連連接和凝結(jié)結(jié)水的排出出都比較方方便。風(fēng)機(jī)盤(pán)盤(pán)管的形式式確定之后后,就是具具體型號(hào)的的選擇。風(fēng)風(fēng)機(jī)盤(pán)管機(jī)機(jī)組的型號(hào)號(hào)根據(jù)房間間所要求的的冷量與風(fēng)風(fēng)量確定,之之后再對(duì)熱熱量進(jìn)行校校核。風(fēng)機(jī)機(jī)盤(pán)管有三三檔風(fēng)量可可供選用,我我國(guó)設(shè)計(jì)人人員習(xí)慣按按中速參數(shù)數(shù)選擇,因因?yàn)?,首先先,我?guó)行行業(yè)標(biāo)準(zhǔn)<<風(fēng)機(jī)盤(pán)管管機(jī)組>>規(guī)定,名名義風(fēng)量(樣樣本上給出出的風(fēng)量)是是在盤(pán)管不不同水,空空氣進(jìn)出口口靜壓為零零的特定工工況下進(jìn)行行測(cè)定的,在在濕工況下下運(yùn)行,會(huì)會(huì)使風(fēng)機(jī)盤(pán)盤(pán)管出力不不足。其次次,在實(shí)際際使用中,風(fēng)風(fēng)機(jī)盤(pán)管特特別是暗裝裝風(fēng)機(jī)盤(pán)管管要加進(jìn)風(fēng)風(fēng)口、回風(fēng)風(fēng)口、過(guò)濾濾器、短風(fēng)風(fēng)管等,加加上過(guò)濾器器渡堵塞、風(fēng)風(fēng)機(jī)盤(pán)管表表面積灰等等諸多因素素的影響,使使得風(fēng)機(jī)盤(pán)盤(pán)管的空氣氣側(cè)阻力增增大,導(dǎo)致致風(fēng)量減小小。如果按按照高檔進(jìn)進(jìn)行選擇,就就會(huì)因風(fēng)量量的不足而而導(dǎo)致冷、熱熱量的不足足。目前,國(guó)產(chǎn)風(fēng)機(jī)機(jī)盤(pán)管樣本本上的冷量量都是按標(biāo)標(biāo)準(zhǔn)測(cè)定的的,冷量的的標(biāo)準(zhǔn)工況況是:室內(nèi)內(nèi)空氣干球球溫度室內(nèi)內(nèi)空氣干球球溫度:227,室內(nèi)內(nèi)空氣濕度度,冷凍水水初溫,供供回水溫差差。在實(shí)際際工程中,表表冷器都是是在非工況況下運(yùn)行的的,此時(shí)可可通過(guò)簡(jiǎn)單單的計(jì)算近近似求出非非標(biāo)準(zhǔn)狀況況下表冷器器所能提供供的冷量。各房房間送風(fēng)狀狀態(tài)的確定定風(fēng)機(jī)盤(pán)管加新風(fēng)風(fēng)系統(tǒng)的空空氣處理方方式有:1)新風(fēng)處理到室室內(nèi)狀態(tài)的的等焓線(xiàn),不不承擔(dān)室內(nèi)內(nèi)冷負(fù)荷,新新風(fēng)單獨(dú)送送入室內(nèi),但但是新回風(fēng)風(fēng)的混合狀狀態(tài)點(diǎn)很難難確定,可可能會(huì)室內(nèi)內(nèi)相對(duì)濕度度過(guò)高,太太高就不能能滿(mǎn)足舒適適的要求了了。2)新風(fēng)處理到室室內(nèi)狀態(tài)的的等含濕量量線(xiàn),新風(fēng)風(fēng)機(jī)組承擔(dān)擔(dān)部分室內(nèi)內(nèi)冷負(fù)荷,新新風(fēng)的這種處理方方案的優(yōu)點(diǎn)點(diǎn)是:a.盤(pán)管表面面干燥,無(wú)無(wú)霉菌滋生生條件,衛(wèi)衛(wèi)生條件好好;b.制冷系數(shù)數(shù)高,能效效底;缺點(diǎn)點(diǎn)是c.冷凍水系系統(tǒng)比較復(fù)復(fù)雜d.信風(fēng)系統(tǒng)統(tǒng)的冷卻設(shè)設(shè)備因負(fù)荷荷增加而需需要加大規(guī)規(guī)格e.風(fēng)機(jī)盤(pán)管管可能出現(xiàn)現(xiàn)不希望的的濕工況。3)新風(fēng)處理到焓焓值小于室室內(nèi)狀態(tài)點(diǎn)點(diǎn)焓值,新風(fēng)機(jī)組組不僅承擔(dān)擔(dān)新風(fēng)冷負(fù)負(fù)荷,還承承擔(dān)部分室室內(nèi)顯熱冷冷負(fù)荷和全全部潛熱冷冷負(fù)荷,風(fēng)風(fēng)機(jī)盤(pán)管僅僅承擔(dān)一部部分室內(nèi)顯顯熱冷負(fù)荷荷,可實(shí)現(xiàn)現(xiàn)等濕冷卻卻,可改善善室內(nèi)衛(wèi)生生和防止水水患。4)新風(fēng)處理到室室內(nèi)狀態(tài)的的等溫線(xiàn)風(fēng)風(fēng)機(jī)盤(pán)管承承擔(dān)的負(fù)荷荷很大,特特別是濕負(fù)負(fù)荷很大,造造成衛(wèi)生問(wèn)問(wèn)題和水患患。5)新風(fēng)處理到室室內(nèi)狀態(tài)的的等焓線(xiàn),并并與室內(nèi)狀狀態(tài)點(diǎn)直接接混合進(jìn)入入風(fēng)機(jī)盤(pán)管管處理,這這種方式室室內(nèi)風(fēng)口布布置均勻,施施工方便,美美化環(huán)境。風(fēng)風(fēng)機(jī)盤(pán)管處處理的風(fēng)量量比其它方方式大,不不易選型。此空調(diào)工程設(shè)計(jì)計(jì)風(fēng)機(jī)盤(pán)管管的新風(fēng)供供給方式,采采用與回風(fēng)風(fēng)混合再處處理到送風(fēng)風(fēng)狀態(tài)點(diǎn)送送入室內(nèi),新新風(fēng)處理到到室內(nèi)狀態(tài)態(tài)的等焓線(xiàn)線(xiàn),不承擔(dān)擔(dān)室內(nèi)冷負(fù)負(fù)荷方案。5送風(fēng)量計(jì)算5.1送風(fēng)量量的計(jì)算公公式人體散濕量mw1=0..278nnφg×10-6(5-1--1)式中mw1——人體散散濕量,kkg/s;;g——成年男男子的小時(shí)時(shí)散濕量,g/h,見(jiàn)[1]表2-13;n——室內(nèi)全全部人數(shù);;φ——群集系系數(shù),見(jiàn)[1]表2-12。室內(nèi)濕負(fù)荷Mw=mw1(kg/ss);熱濕比ε=Qc/Mww(kJ/kkg);(5-1--2)送風(fēng)量Ms=QQc/(hR-hs)(5-1--3)式中Ms——送風(fēng)量量,kg//s;Qc——室內(nèi)全全熱冷負(fù)荷荷,kw;hR、hs——分別為室內(nèi)內(nèi)空氣和送送風(fēng)的比焓焓,kJ//kg;5.2送風(fēng)量的的計(jì)算過(guò)程程及結(jié)果以101接待室為為例1)空氣處理理方案及有有關(guān)參數(shù)的的查取采用新風(fēng)直入式式空氣處理理方式,新新風(fēng)機(jī)組不不承擔(dān)室內(nèi)內(nèi)負(fù)荷,出出于降低空空調(diào)投資和和節(jié)能等方方面的考慮慮,一般商場(chǎng)場(chǎng)空氣處理理均不設(shè)再再熱器,因因而室內(nèi)的的相對(duì)濕度度往往會(huì)超超過(guò)規(guī)范所所要求的數(shù)數(shù)值??諝馓幚矸桨高^(guò)過(guò)程線(xiàn)如下下圖:圖5-1空氣氣處理方案案過(guò)程圖(1)確定室室內(nèi)狀態(tài)點(diǎn)點(diǎn)R。根據(jù)夏夏季室內(nèi)溫溫度tR=25,相相對(duì)濕度==65%的要求,確確定室內(nèi)空空氣狀態(tài)點(diǎn)點(diǎn)R,并差h--d圖得到到,室內(nèi)焓焓值hR=58..44kJJ/Kg。(2)做熱濕濕比線(xiàn)。根根據(jù)計(jì)算出出的室內(nèi)冷冷負(fù)荷Q=5.0029KWW,濕負(fù)荷荷S=0.00002778Kg//s,計(jì)算熱濕濕比=5..029//0.00002788=180089kJ/Kgg。確定送送風(fēng)狀態(tài)點(diǎn)點(diǎn)S。(3)確定送送風(fēng)狀態(tài)點(diǎn)點(diǎn)S。本系統(tǒng)統(tǒng)擬采用表表冷器作為為降溫去濕濕的空氣處處理設(shè)備,以以空氣處理理到=955%的機(jī)器露露點(diǎn)(風(fēng)機(jī)溫升升在此設(shè)計(jì)計(jì)中過(guò)小,故故不在考慮慮之中)與與熱濕比線(xiàn)線(xiàn)相交,此此點(diǎn)即為點(diǎn)點(diǎn)S,并由此此得到:送風(fēng)點(diǎn)S的參數(shù)數(shù)=17..47,=51..9kJ/KKg,=12..75g//kg。(4)計(jì)算房房間的總送送風(fēng)量G。計(jì)算熱熱量平衡和和濕量平衡衡,可得::G=Q/(hRR-hs))=5.0029/((58.444-511.9)==0.566(kg/s)=13444.48((m3/h)G=s/(dRR-ds))=10000×0.1224/(114.977-12..66)==0.555(kg/s)=11342..57(mm3/h)按照消除余熱和和余濕所求求通風(fēng)量相相同,說(shuō)明明計(jì)算無(wú)誤誤。其他房間的計(jì)算算方法如上上,其數(shù)據(jù)列列與下表表5-1送風(fēng)量的的計(jì)算與校校核房間編號(hào)冷負(fù)荷w濕負(fù)荷J/kgg熱濕比kJ/kkg送風(fēng)點(diǎn)焓值kJJ/kg室外焓值kJ//kg送風(fēng)量Kg/s送風(fēng)量m3/h10150291.001414433.77958.4454.700.771450.00010242301.001415206.77158.4455.330.651550.00010359070.600835394.88153.2550.850.982461.25510448581.001417464.33558.4455.800.832084.56610549701.001414164.11758.4454.890.881430.000大廳南80331.37321062.44958.4456.011.323302.144大廳北37931.089212536.55458.4455.360.491230.16620125620.200346046.99353.2549.920.31768.6020228620.200351438.88453.2549.950.35868.1120359040.600835376.88358.4456.040.982460.80020436430.300443657.77953.2549.900.431087.47720525860.200346478.22853.2549.920.31775.80大廳南53180.49438754.66658.4452.060.33833.63大廳北24960.689813026.33858.4455.410.33822.8630141521.001414926.33058.4455.570.581448.38830240861.001414689.00458.4455.560.571417.11130372121.502117284.66058.4455.691.052622.54430452321.502112539.22558.4455.360.681696.87730541761.001415012.55858.4455.570.581456.744大廳南63340.586738865.55258.4451.670.37936.22大廳北24960.689813026.33858.4455.410.33822.8640130680.400627570.66453.2549.700.35864.2340230830.400627705.44453.2549.700.35868.4540356320.600833747.00053.2549.800.651632.47740437110.400633348.99853.2550.170.481205.39940530920.400627786.33253.2549.700.35870.98大廳南63340.586738865.55258.4451.550.37919.38大廳北24960.689813026.33858.4455.410.33822.8650127570.200349551.66753.2550.460.40989.5350237140.200366751.88753.2550.020.461148.66650351320.300461502.00053.2550.000.631579.08850436430.300443657.77953.2549.900.431087.47750527810.200349983.00353.2550.360.38961.93大廳南63340.586738865.55258.4451.990.39982.04大廳北24960.689813026.33858.4455.410.33822.8660145001.001416177.33558.4455.870.781750.00060246901.001416860.44058.4455.670.681695502118214.55058.4455.781.212854.00060459001.502114140.22058.4455.510.802011.04460543251.001415548.22358.4450.390.781679.000大廳南51450.52135550.88658.4451.240.862143.755大廳北60210.726129852.00958.4451.090.982457.555合計(jì)18628930.2525.1560871.9915.3風(fēng)機(jī)盤(pán)盤(pán)管及新風(fēng)風(fēng)機(jī)組的選選擇以101接待室為為例:所選的風(fēng)機(jī)盤(pán)管管要求當(dāng)進(jìn)進(jìn)水溫度為為7℃時(shí),進(jìn)風(fēng)風(fēng)參數(shù)D
溫馨提示
- 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶(hù)所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶(hù)上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶(hù)上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶(hù)因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 禮堂室內(nèi)設(shè)計(jì)服務(wù)協(xié)議
- 人房屋租賃合同范例
- 倉(cāng)儲(chǔ)服務(wù)對(duì)象合同范本
- 公路 bot 運(yùn)營(yíng)合同范本
- 教學(xué)質(zhì)量績(jī)效考核方案
- 齒榫開(kāi)榫機(jī)行業(yè)行業(yè)發(fā)展趨勢(shì)及投資戰(zhàn)略研究分析報(bào)告
- 加工定價(jià)合同范例
- 輕便多功能縫紉機(jī)行業(yè)深度研究報(bào)告
- 電子產(chǎn)品保稅區(qū)運(yùn)輸承諾函
- 電子競(jìng)技Esports產(chǎn)業(yè)的崛起與影響
- 2024年極兔速遞有限公司招聘筆試參考題庫(kù)附帶答案詳解
- 中醫(yī)中藥在罕見(jiàn)病中的應(yīng)用
- 2024-2030年中國(guó)無(wú)人機(jī)光電吊艙行業(yè)市場(chǎng)深度研究及投資規(guī)劃建議報(bào)告
- 征兵工作試題
- TCALC 003-2023 手術(shù)室患者人文關(guān)懷管理規(guī)范
- 2021新安全生產(chǎn)法解讀
- 腦卒中后吞咽障礙患者進(jìn)食護(hù)理-2023中華護(hù)理學(xué)會(huì)團(tuán)體標(biāo)準(zhǔn)
- 半生熟紙制作工藝
- 湖北省普通高中2022-2023學(xué)年高一下學(xué)期學(xué)業(yè)水平合格性考試模擬化學(xué)(一)含解析
- 銀行案件防控培訓(xùn)課件
- 裝配式混凝土結(jié)構(gòu)施工技術(shù)講課課件
評(píng)論
0/150
提交評(píng)論