版權(quán)說(shuō)明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡(jiǎn)介
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:24:21GMT+00:002006,UncontrolledCopy,(c)BSI
BRITISHSTANDARD
Compressedair—
Part5:Testmethodsforoilvapourandorganicsolventcontent
ICS71.100.20;23.140
NOCOPYINGWITHOUTBSIPERMISSIONEXCEPTASPERMITTEDBYCOPYRIGHTLAW
BSISO
8573-5:2001
BSISO8573-5:2001
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:24:21GMT+00:002006,UncontrolledCopy,(c)BSI
Nationalforeword
ThisBritishStandardreproducesverbatimISO8573-5:2001andimplementsitastheUKnationalstandard.
TheUKparticipationinitspreparationwasentrustedtoTechnicalCommitteeMCE/8,Compressors,pneumatictools,pneumaticmachinesandvacuum
technology,whichhastheresponsibilityto:
—aidenquirerstounderstandthetext;
—presenttotheresponsibleinternational/Europeancommitteeany
enquiriesontheinterpretation,orproposalsforchange,andkeepthe
UKinterestsinformed;
—monitorrelatedinternationalandEuropeandevelopmentsandpromulgatethemintheUK.
Alistoforganizationsrepresentedonthiscommitteecanbeobtainedonrequesttoitssecretary.
Cross-references
TheBritishStandardswhichimplementinternationalpublicationsreferredtointhisdocumentmaybefoundintheBSIStandardsCatalogueunderthe
sectionentitled“InternationalStandardsCorrespondenceIndex”,orbyusingthe“Find”facilityoftheBSIStandardsElectronicCatalogue.
ABritishStandarddoesnotpurporttoincludeallthenecessaryprovisionsofacontract.UsersofBritishStandardsareresponsiblefortheircorrect
application.
CompliancewithaBritishStandarddoesnotofitselfconferimmunityfromlegalobligations.
ThisBritishStandard,havingbeenpreparedunderthe
directionoftheEngineeringSectorPolicyandStrategy
Committeetitlehere,was
publishedundertheauthorityoftheStandardsPolicyand
StrategyCommitteeon
1March2002
?BSI1March2002
ISBN058039039X
Summaryofpages
Thisdocumentcomprisesafrontcover,aninsidefrontcover,theISOtitlepage,pagesiitoiv,pages1to11andabackcover.
TheBSIcopyrightdatedisplayedinthisdocumentindicateswhenthedocumentwaslastissued.
Amendmentsissuedsincepublication
Amd.No.
Date
Comments
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:24:21GMT+00:002006,UncontrolledCopy,(c)BSI
INTERNATIONAL
STANDARD
ISO
8573-5
Firstedition2001-12-15
Compressedair—
Part5:
Testmethodsforoilvapourandorganicsolventcontent
Aircomprimé—
Partie5:Méthodesd'essaipourlateneurenvapeursd'huileetensolvantsorganiques
ReferencenumberISO8573-5:2001(E)
ii
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:24:21GMT+00:002006,UncontrolledCopy,(c)BSI
iii
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:24:21GMT+00:002006,UncontrolledCopy,(c)BSI
ISO8573-5:2001(E)
Page
Contents
Foreword iv
1Scope
1
2Normativereferences
1
3Termsanddefinitions
2
4Oilvapourclasses
2
5Testmethods
2
6Sampling
2
7Measurement
3
8Evaluationoftestresults
4
9Uncertainty
4
10Testreport
5
AnnexA(normative)Testprocedures
7
AnnexB(informative)Dalton’slawofpartialpressure
10
Bibliography
11
iv
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:24:21GMT+00:002006,UncontrolledCopy,(c)BSI
ISO8573-5:2001(E)
Foreword
ISO(theInternationalOrganizationforStandardization)isaworldwidefederationofnationalstandardsbodies(ISO
memberbodies).TheworkofpreparingInternationalStandardsisnormallycarriedoutthroughISOtechnical
committees.Eachmemberbodyinterestedinasubjectforwhichatechnicalcommitteehasbeenestablishedhas
therighttoberepresentedonthatcommittee.Internationalorganizations,governmentalandnon-governmental,in
liaisonwithISO,alsotakepartinthework.ISOcollaboratescloselywiththeInternationalElectrotechnical
Commission(IEC)onallmattersofelectrotechnicalstandardization.
InternationalStandardsaredraftedinaccordancewiththerulesgivenintheISO/IECDirectives,Part3.
ThemaintaskoftechnicalcommitteesistoprepareInternationalStandards.DraftInternationalStandardsadoptedbythetechnicalcommitteesarecirculatedtothememberbodiesforvoting.PublicationasanInternationalStandardrequiresapprovalbyatleast75%ofthememberbodiescastingavote.
AttentionisdrawntothepossibilitythatsomeoftheelementsofthispartofISO8573maybethesubjectofpatentrights.ISOshallnotbeheldresponsibleforidentifyinganyorallsuchpatentrights.
InternationalStandardISO8573-5waspreparedbyTechnicalCommitteeISO/TC118,Compressors,pneumatictoolsandpneumaticmachines,SubcommitteeSC4,Qualityofcompressedair.
ISO8573consistsofthefollowingparts,underthegeneraltitleCompressedair:
—Part1:Contaminantsandpurityclasses
—Part2:Testmethodsforaerosoloilcontent
—Part3:Testmethodsformeasurementofhumidity
—Part4:Testmethodsforsolidparticlecontent
—Part5:Testmethodsforoilvapourandorganicsolventcontent
—Part6:Testmethodsforgaseouscontaminantcontent
—Part7:TestmethodsforviablemicrobiologicalcontaminantcontentThefollowingpartsareunderpreparation:
—Part8:Testmethodsforsolidparticlecontentbymassconcentration
—Part9:Testmethodsforliquidwatercontent
AnnexAformsanormativepartofthispartofISO8573.AnnexBisforinformationonly.
1
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:24:21GMT+00:002006,UncontrolledCopy,(c)BSI
INTERNATIONALSTANDARD
ISO8573-5:2001(E)
Compressedair—
Part5:
Testmethodsforoilvapourandorganicsolventcontent
1Scope
ThispartofISO8573specifiesthegaschromatographytestmethodfordeterminingthecontentofoilvapour(hydrocarbonsofsixormorecarbonatoms)incompressedair,regardlessofthesourceofthecompressedair,aswellasofanyorganicsolventsinthevapour,difficulttoseparatefromtheotherhydrocarbons.Italsogivesguidelinesontheuseofchemicalindicatortubesasaninitialindicationofthepresenceofoilvapour.
ThispartofISO8573elaboratessampling,measurement,evaluation,uncertaintyconsiderationsandreportinginrespectofthecompressedairpurityclassparameter,oilvapour,inaccordancewithISO8573-1.
NOTELighterhydrocarbonscomposedoffiveorlesscarbonatomsaredealtwithasgaseouscontaminantsin8573-6.
2Normativereferences
Thefollowingnormativedocumentscontainprovisionswhich,throughreferenceinthistext,constituteprovisionsofthispartofISO8573.Fordatedreferences,subsequentamendmentsto,orrevisionsof,anyofthesepublicationsdonotapply.However,partiestoagreementsbasedonthispartofISO8573areencouragedtoinvestigatethepossibilityofapplyingthemostrecenteditionsofthenormativedocumentsindicatedbelow.Forundatedreferences,thelatesteditionofthenormativedocumentreferredtoapplies.MembersofISOandIECmaintainregistersofcurrentlyvalidInternationalStandards.
ISO2591-1,Testsieving—Part1:Methodsusingtestsievesofwovenwireclothandperforatedmetalplate
ISO3857-1,Compressors,pneumatictoolsandmachines—Vocabulary—Part1:General
ISO5598,Fluidpowersystemsandcomponents—Vocabulary
ISO8573-1:2001,Compressedair—Part1:Contaminantsandpurityclasses
ISO8573-2:1996,Compressedairforgeneraluse—Part2:Testmethodsforaerosoloilcontent
ISO8573-3,Compressedair—Part3:Testmethodsformeasurementofhumidity
ISO9486,Workplaceair—Determinationofvaporouschlorinatedhydrocarbons—Charcoaltube/solventdesorption/gaschromatographicmethod
ISO9487,Workplaceair—Determinationofvaporousaromatichydrocarbons—Charcoaltube/solvent
desorption/gaschromatographicmethod
2
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:24:21GMT+00:002006,UncontrolledCopy,(c)BSI
ISO8573-5:2001(E)
3Termsanddefinitions
ForthepurposesofthispartofISO8573,thetermsanddefinitionsgiveninISO3857-1,ISO5598andISO8573-1,andthefollowingapply.
3.1
mesh
indicationofparticlesizeresultingfromthegradingofsolidsbytheuseofsieveswithdefinedholesizes
3.2
oil
mixtureofhydrocarbonscomposedofsixormorecarbonatoms(C6)
3.3
organicsolvent
mixtureofoneoracombinationofthefollowingidentifiedgroups:alcohols,halogenichydrocarbons,esters,esters/etheralcohols,ketones,aromatic/alfatichydrocarbons
NOTEThesecompoundsarecharacterizedbyaconsiderablevapourpressureundergivenconditions,whenairsamplesareanalysed.
4Oilvapourclasses
OilvapourisincludedinthetotaloilconcentrationfigureusedforclassificationinTable4ofISO8573-1:2001.
5Testmethods
Selectionoftheavailabletestmethodsdependsontherangeofoilvapourcontentinthecompressedair.
—Gaschromatography(seeclauseA.1)isapplicableforoilvapourcontentintherange0,001mg/m3to10mg/m3.
—Chemicalindicatortubes(seeclauseA.2)aretobeusedasapreliminarymethodonly,forcheckingpurposesandasaninitialinvestigation,afterwhichthegaschromatographymethodshallbeemployed.
6Sampling
6.1General
Thequantificationoftheoilvapourcontentinacompressedairsystemshallbecarriedoutwithinthefollowingconstraints.
Thesampleshallbefreefrominterferingcontaminants,forexample,watervapour,oilaerosol.
Thesamplingandanalysisoftheoilvapourshallbeperformedusingaconstantflowrate.
Airflowisnormallydivertedthroughthetestequipmentviasuitablein-linevalves.Theseshallhavebeencheckedtoensuretheydonotcontributetothelevelofcontaminationalreadypresent.Particularattentionshallbegiventothecleanlinessofthetestequipment,andotherprecautionsshallbetaken,forexample,valvepurgingandstabilizationtoconstanttestconditions.Goodanalyticaltechniqueshelpimprovetheconfidencelevelofthemeasurements.
Flowmeasurementisrequiredtodeterminethevolumeofairusedduringthetest,regardlessofthemethod.
3
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:24:21GMT+00:002006,UncontrolledCopy,(c)BSI
ISO8573-5:2001(E)
Thetemperatureandvelocityrangeshallbewithintherangesspecifiedbythemanufacturerofthetestequipment.
SeeclauseA.1forthesamplingprocedure.
6.2Extraction
Theprobeshallbeinstalledinasmallextractiontube,whichconductsanairsamplefromthemainpipeintothemeasurementchamber,wherethemeasurementshallbemadeundersystempressure.
6.3Samplingandmeasurementconditions
6.3.1Repeatability
Dependingontherepeatabilityofthemethodandtheexperienceofthepartiesinvolvedintheprovisionofmeasurementfacilities,anumberofsequentialmeasurementsmayneedtobecarriedout.
6.3.2Samplingsystem
Materialsusedforconductingtheairinthesamplingsystemshallnotaffecttheoilvapourcontentofthesample.
Thesamplingsystempressureshallberecordedduringmeasurement.
Thesamplingsystemtemperatureshallbehigherthantheprevailingdew-pointandshallberecordedduringmeasurement(seeISO8573-3).
6.3.3Measurementsystem
Thecompressedairsystemandsamplingsystemshallhavereachedasteadystatebeforeanymeasurementiscarriedoutandshallbekeptsteadyduringmeasurement.Thereadingsfromtwoconsecutivemeasurements,havingbetweenthemanintervalofatleast20minutes,maynotdifferbymorethanisimpliedbytheaccuracyofthemeasuringsystem.
6.3.4Testequipment
ThegeneralarrangementofthetestequipmentforextractingasampleshallbeasshowninFigureA.1.Itisimportantthatthetestequipmentnotaffectthecollectedsample.
Precautionsshallbetakentoensurethereisnotemperaturedropbetweenthecompressedairsystemandthecollectionpoint.PracticalproceduresasidentifiedinISO8573-2shouldalsobeconsidered.
7Measurement
Considerationshallbegiventothecalibrationrequirementsofthemeasurementequipmentused,asdescribedinapplicableinstructions,andtothedegreeofvapourconcentrationbeingmeasured.
Therequirementsonequipmenthandling,measurementandevaluationshallbeaccordingtoMethodB2ofISO8573-2:1996.
SeeclauseA.1forspecificationofthegaschromatographytestprocedure.
Prepareformeasurementbycleaninganddegreasingthemeasuringandstainlesssteeltubeswithasolventthat
doesnotaddtotheoverallhydrocarboncontentofthesample.Beforemeasuring,flushthesamplepointandthestainlesssteeltubeuptothemembranefilterwithcompressedairfromthesystem,forexample,for5min.
ReferenceshouldbemadetoISO9486andISO9487withregardtomethodology.
4
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:24:21GMT+00:002006,UncontrolledCopy,(c)BSI
ISO8573-5:2001(E)
Checkthestandardreferenceconditionsfortheflowmeter.
8Evaluationoftestresults
8.1Referenceconditions
Unlessotherwiseagreed,thereferenceconditionsforoilvapourconcentrationstatementsshallbethefollowing.
—Compressedairtemperature:20∞C.
—Compressedair:1bar1)absolute.
—Relativewatervapourpressure:0.
8.2Influenceofhumidity
Thehumidityshallbelessthan75%andwithinthelimitsofthemeasurementequipmentasdeclaredbytheequipmentmanufacturer.Theappropriatecalibrationprocedureforthemeasurement,asgiveninthemanufacturer’sliterature,shouldbefollowed.
8.3Influenceofpressureandtemperature
Oilvapourconcentrationshallberecalculatedtoreferencepressureconditionsusingthefollowingformula:
prefttest
cref=ctest??
ptesttref
where
crefconcentrationatreferenceconditions;
ctestconcentrationattestconditions;
prefreferencepressure(absolute);
ptesttestpressure(absolute);
trefreferencetemperature(absolute);
ttesttesttemperature(absolute).
Thevolumeflowrateoftheairisinfluencedbytemperature.SeeannexB.
9Uncertainty
NOTEAcalculationoftheprobableerroraccordingtothisclauseisnotalwaysnecessary.
Duetotheverynatureofphysicalmeasurements,itisimpossibletomeasureaphysicalquantitywithouterroror,infact,todeterminethetrueerrorofanyoneparticularmeasurement.However,iftheconditionsofthemeasurementaresufficientlywell-known,itispossibletoestimateorcalculateacharacteristicdeviationofthemeasuredvalue
1)1bar=0,1MPa=105Pa;1MPa=1N/mm2
5
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:24:21GMT+00:002006,UncontrolledCopy,(c)BSI
ISO8573-5:2001(E)
fromthetruevalue,suchthatitcanbeassertedwithacertaindegreeofconfidencethatthetrueerrorislessthanthesaiddeviation.
Thevalueofsuchadeviation(normally95%confidencelimit)constitutesacriterionoftheaccuracyoftheparticularmeasurement.
Itisassumedthatallsystematicerrorsthatmayoccurinthemeasurementoftheindividualquantities,andofthecharacteristicsoftheair,maybecompensatedforbycorrections.Afurtherassumptionisthattheconfidencelimitsinerrorsinreadingandintegrationerrorsmaybenegligibleifthenumberofreadingsissufficient.
The(small)systematicerrorsthatmayoccurarecoveredbytheinaccuracyofmeasurements.
Qualityclassificationsandlimitsoferrorareofteninvokedforascertainingtheuncertaintyofindividualmeasurementbecause,apartfromtheexceptions(e.g.electricaltransducers),theyconstituteonlyafractionofthequalityclassorthelimitoferror.
Theinformationaboutascertainingtheuncertaintyofthemeasurementoftheindividualquantitiesmeasuredandontheconfidencelimitsofthegaspropertiesareapproximations.Theseapproximationscanonlybeimprovedatadisproportionateexpense.SeeISO2602andISO2854.
10Testreport
10.1Statements
Statementsoftheoilvapourororganicsolventcontentinthecompressedair,orboth,shallonlybeusedinconjunctionwithstatementsonoilaerosolcontentwhenmadeforclassificationpurposesaccordingtoISO8573-1,andshallbemadeinsuchamannerthatthevaluescanbeverifiedaccordingtotheproceduresofthemeasurementmethodsspecifiedinthispartofISO8573.
StatementsaccordingtothispartofISO8573shallnotbeusedtocharacterizeoilcontentinairwithoutmentionthatthetotalamountofoilisnotconsidered.
10.2Information
ThetestreportusedtodeclareoilvapourconcentrationaccordingtothispartofISO8573shallcontainthefollowinginformation:
a)adescriptionofthecompressedairsystemanditsworkingconditions,withsufficientdetailtodeterminetheapplicabilityofthedeclaredconcentrationvalue,including
—pressure,
—temperature,and
—othercontaminants;
b)adescriptionofthesamplingpointatwhichthesamplesweretaken;
c)adescriptionofthesamplingandmeasurementsystemused,inparticularthematerialsused,anddetailsofitscalibrationrecord;
d)thephrase“Declaredcontentofoilvapourinmg/m3inaccordancewithISO8573-5”,followedby
—thefigurefortheactual,averagemeasuredvalueevaluatedaccordingtoclause8,calculatedinrespectofthereferenceconditions,
6
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:24:21GMT+00:002006,UncontrolledCopy,(c)BSI
ISO8573-5:2001(E)
—thefigurefortheactual,averagemeasuredvalueevaluatedaccordingtoclause8,calculatedinrespectoftheactualconditions,
—thepressuretowhichthemeasurementrefers,
—astatement,followingthefigure,inrespectoftheapplicableuncertainty,and
—thedateofthecalibrationrecord;
e)thedateofthesamplingandmeasurements.
7
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:24:21GMT+00:002006,UncontrolledCopy,(c)BSI
ISO8573-5:2001(E)
AnnexA
(normative)
Testprocedures
A.1Gaschromatography
A.1.1Samplingprocedure
Carryouttheprocedureasfollows,andasshowninFigureA.1.
a)ConnecttheextractiontubeinFigureA.1totheshut-offvalve(6)atthemeasuringpoint.b)Connectshut-offvalves7and8withthesilencer(3).
c)Closeallvalves.
d)Openshut-offvalves6,7and8slowly.
Key
1Membraneholdera7Shut-offvalve
2Stainlesssteeltube(seeFigureA.2)forcollection8Shut-offvalve
ofoilvapourandorganicsolvents9Flow-controlvalve
3Silencer10Flow-controlvalveb
4Pressuregauge11Flowmeter
5Temperaturegauge12Mainpipe
6Shut-offvalve
aThemembraneistoprotectthestainlesssteeltubefromcontaminationbyaerosols.
bThisflow-controlvalve(10)istobeusedonlyiftheflowmetercanoperateunderpressure.
FigureA.1—Gaschromatography—Samplingprocedure
8
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:24:21GMT+00:002006,UncontrolledCopy,(c)BSI
ISO8573-5:2001(E)
e)Flush(cleaningprocess)thesystemfor5min.
f)Closeallvalves.
g)ConnecttherestofthemeasuringsystemaccordingtoFigureA1.
h)Closeallvalves.
i)Openshut-offvalves6,7and8fullytopressurizethetestequipment.
j)Adjusttheflow,usingtheflow-controlvalves(9,10)ontheflowmeter(11).
k)Afterthesamplingtime,closetheshut-offvalve(6)attheinletoftheextractiontube.Thesamplingtimeshall
belongenoughsothat0,001mgto1mgmassisadsorbedpertubeinthemainzone.Theminimumcontattimeshallbe0,1s,wherethecontacttimeisthevolumeofthecharcoalofthemainzonedividedbytheactualflowrateofthecompressedair.
l)Disconnectthemembraneholder(1)andthestainlesssteeltube(2),andplugopentheends.ThestainlesssteeltubeshallbeasshowninFigureA.2.
Key
1Stainlesssteeltube
2Quartzwoolseparator
3Perforatedstainlesssteeldisc
41/4-inchconnection
dLengthofmainzone,with3gcharcoal:100mm
eLengthofback-upzone,with1gcharcoal:40mm
fInternaldiameterofsteeltube:10mm
aFlowdirection.
FigureA.2—Stainlesssteeltube
A.1.2Samplepreparation
Thestainlesssteelmeasuringtubeshallcontain3gcoconutcharcoal(<75%relativehumidity)inthemainzoneand1gcoconutcharcoalintheback-upzone(seeFigureA.2).Themaximumcontentoftheadsorbedoilvapourororganicsolventintheback-upzoneshallbeintheregionof10%to25%bymass.Thesorbentis20/40meshcoconutcharcoalinaccordancewithISO2591-1.
Althoughthemostwidelyavailableadsorbentforthisapplicationiscoconutcharcoal,whereanalternativeadsorbentexiststhatprovidesthesameperformance,itmaybesubstituted.
9
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:24:21GMT+00:002006,UncontrolledCopy,(c)BSI
ISO8573-5:2001(E)
A.1.3Determination
Analysethemainzoneandtheback-upzoneseparately,togetherwitha“blind-test”,usingthefollowingprocedure.
a)Extractthemainzoneandtheback-upzoneusingcarbondisulphide.Usebenzene-d6,toluene-d8,
ethylbenzene-d10andoctane-d18asinternalstandards.
b)Extractthesorbentsampletubefor30minonashaker.
c)Analysetheextractusingagaschromatographwithmass-spectroscopicdetectioninfullscanmode,analysingbothblindtestsandstandardsinthesameway.
d)Identifydominantsinglecomponentsasfaraspossible.Characterize,sumandcalculateothersingle
components(e.g.aliphaticandaromaticcompounds)semi-quantitativelyastoluene.
Thedetectionlimitsshallbe0,1μgto0,5μgpertube.
A.1.4Calculation
TheprinciplesgiveninISO8573-2regardinganalyticalmethodsandrelatedcalculationsshouldbeapplied.
A.2Chemicalindicatortubes
ForthepurposesofthispartofISO8573,detectortubesmaybeemployedtoprovideaninitialindicationofthepresenceofoilvapour.Onceidentified,thegaschromatographymethodaccordingtoclauseA.1shallbeusedtoidentifythequantitativeaspectoftheoilvapourpresentinthecompressedair.
Fordetailedinformationregardingtheapplicationofdetectortubesrefertothemanufacturer'sliterature.
10
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:24:21GMT+00:002006,UncontrolledCopy,(c)BSI
ISO8573-5:2001(E)
AnnexB
(informative)
Dalton’slawofpartialpressure
coil=
Mr,oil?poil
Mr,air?pabs
where
coilistheoilconcentrationratio;
Mr,oilisthemolecularweightofoil;
Mr,airisthemolecularweightofair;
poilisthevapourpressureofoil,inbar;
pabsistheabsolutepressure,inbar.
11
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:24:21GMT+00:002006,UncontrolledCopy,(c)BSI
ISO8573-5:2001(E)
Bibliography
[1]ISO2602,Statisticalinterpretationoftestresults—Estimationofthemean—Confidenceinterval
[2]ISO2854,Statisticalinterpretationofdata—Techniquesofestimationandtestrelatingtomeansandvariances
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:24:21GMT+00:002006,UncontrolledCopy,(c)BSI
BSISO
8573-5:2001
BSI
389ChiswickHighRoadLondon
W44AL
BSI—BritishStandardsInstitution
BSIistheindependentnationalbodyresponsibleforpreparing
BritishStandards.ItpresentstheUKviewonstandardsinEuropeandattheinternationallevel.ItisincorporatedbyRoyalCharter.
Revisions
BritishStandardsareu
溫馨提示
- 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 防毒品安全教育中班
- 廚師合伙合同范例
- 租賃抽水設(shè)備合同范例
- 人才引進(jìn)居間合同范例
- 賣菜合同范例
- 車隊(duì)聘用合同范例
- 個(gè)人汽車押車合同范例
- 代理 經(jīng)銷 合同范例
- 個(gè)人過(guò)戶二手車合同范例
- 凈水訂購(gòu)合同范例
- 商店進(jìn)銷存管理系統(tǒng)
- 《mc入門教程》課件
- 泡沫瀝青就地冷再生
- 公關(guān)專業(yè)團(tuán)隊(duì)建設(shè)方案
- 汽車概論論文-混合動(dòng)力汽車的發(fā)展現(xiàn)狀和發(fā)展趨勢(shì)
- 分布式光伏發(fā)電項(xiàng)目投標(biāo)技術(shù)方案(純方案)
- 增強(qiáng)指數(shù)策略
- 能源中國(guó)學(xué)習(xí)通課后章節(jié)答案期末考試題庫(kù)2023年
- 寧夏困難殘疾人生活補(bǔ)貼申請(qǐng)審批表
- 2023湖南省永州市七年級(jí)上學(xué)期語(yǔ)文期末試卷及答案
- 昌建明源銷售系統(tǒng)上線培訓(xùn)
評(píng)論
0/150
提交評(píng)論