1、電氣試驗(yàn) Electric Test1. 電氣試驗(yàn)常規(guī)要求 General Requirements1) 電氣預(yù)防性的試驗(yàn)嚴(yán)格按規(guī)范、產(chǎn)品說(shuō)明書要求執(zhí)行。Electric preventive test shall be carried out in accordance with criterion and product specification strictly.2) 組合式微機(jī)保護(hù)及監(jiān)控繼電器按產(chǎn)品說(shuō)明書進(jìn)行整定。Adjust combined micro-computer protection and monitoring relay3) 常規(guī)的電磁式繼電器調(diào)試按新編保護(hù)繼電器檢驗(yàn)
2、中有關(guān)規(guī)定進(jìn)行調(diào)試。The normal electromagnetic relay commissioning shall comply with the stipulations ofNewProtection Relay Test.4) 盤(柜 )指示電表經(jīng)校驗(yàn)后,對(duì)合格的電表粘貼專用合格證。After calibration of the panel (cabinet) indicative ammeter, paste special quality certificate on the qualified ammeter.5) 高壓開關(guān)柜的傳動(dòng)試驗(yàn)在各電氣元件及單體柜調(diào)試后進(jìn)行。
3、傳動(dòng)試驗(yàn)時(shí), 認(rèn)真核對(duì) 各回路的準(zhǔn)確及可靠性。主要傳動(dòng)試驗(yàn)項(xiàng)目:High pressure switchboard transmission test shall be carried out after electrical element and individual cabinet commissioning. Check the loops accuracy and liability during transmission test. The main transmission project :操作控制回路傳動(dòng)試驗(yàn);Operation Control Loop Transmissi
4、on Test保護(hù)回路傳動(dòng)試驗(yàn);Loop Protection Transmission Test測(cè)量 /計(jì)量回路試驗(yàn);Measure/Recording Loop Test 系統(tǒng)低電壓、斷線保護(hù)試驗(yàn);System Low Pressure, Cable break protection test核對(duì)一、二次相位;Check 1st and 2nd phase2. 變壓器試驗(yàn) Transformer Test1)測(cè)量繞組連同套管的直流電阻,測(cè)量應(yīng)在各分接頭所有位置上進(jìn)行;Measure wi ndi ng and sleeve DC resista nee of all the connect
5、ion joi nts.2)對(duì)1600kVA及以下三相變壓器,各相測(cè)得值的相互差值應(yīng)小于平均值的4%,線間測(cè)得值的相互差值應(yīng)小于平均值的2%; 1600kVA以上的三相變壓器,各相測(cè)得值的相互差值應(yīng)小于平均值的2%,線間測(cè)得值的相互差值應(yīng)小于平均值的1% ; 1600kVA以上的三相變壓器,各相測(cè)得值的相互差值應(yīng)小于平均值的2%,線間測(cè)得值的相互差值應(yīng)小于平均值的1%;(重復(fù))三相電阻不平衡率計(jì)算Three Phase Transformer of 1600Kva and the less, the measured value s differenee shall be4% less tha
6、 n the average, intern al li nes measured value shall be 2% less tha n the average.Three Phase Transformer of above 1600kVA, the measured value differenee shall be 2% less tha n the average, intern al li nes measured value shall be 1% less tha n the average, Three Phase resista nceUn bala nee Rate c
7、alculati on formula:不平衡率三相實(shí)測(cè)最大值最小值三相算術(shù)平均值100%Measured Max-Mi nUn bala need Rate= 100%Average3)直阻測(cè)量方法:DC Resista nee Measure Method用感性負(fù)載速測(cè)歐姆計(jì)測(cè)量繞組直流電阻時(shí),其接線及測(cè)量方法應(yīng)符合測(cè)試 儀器的技術(shù)要求。When measuri ng winding DC resista nee by sen sibility load ohmmeter, the connection and the measure method shall comply with eq
8、uipme nt tech ni cal requireme nts.4)變壓器的直流電阻,與同溫下產(chǎn)品出廠實(shí)測(cè)數(shù)值比較,相應(yīng)變化不應(yīng)大于2%;將不同溫度下的繞組直流電阻溫度換算到同一溫度:DC resista nee of tran sformer, compared with measured value of product by manu faeturer un der same temperature, the corresp onding cha nge shall be not more tha n 2%, convert the winding DC resista nee u
9、n der differe nt temperature into the same temperature.RxRaTtxTta(式中:Rx -換算至溫度為tx時(shí)的電阻; Ra溫度為ta時(shí)所測(cè)得的電阻;T-溫度 換算系數(shù),銅線為235,鋁線為225; tx-需要換算Rx的溫度;ta-測(cè)量Ra時(shí)的溫度)(convert Rx into the resista nee un der temperature of tx, Ra is resista nee un der temperature of ta, T is temperature convert coefficie nt, copper
10、 line is 235, alu minum is 225, tx is the temperature of Rx to con vert, ta is temperature of measuri ng Ra )5)由于變壓器結(jié)構(gòu)等原因,差值超過(guò)本條第款時(shí),可只按本條第款進(jìn)行比較。Cause of tran sformer structure, the differe nee is more tha n clause 2, comply with clause 4 on ly.6)檢查所有分接頭的變壓比變壓比與制造廠名牌數(shù)據(jù)相比應(yīng)無(wú)明顯差別,且符合變比的規(guī)律。額定分接的變壓比允許偏差為)
11、.5%,其它分接的偏差應(yīng)在變壓器阻抗值(%)的1/10以內(nèi),但不超過(guò) 1%。Check all connection joints transforming ratio, which shall be no distinet differenee compared with the date of manu facturer brand and comply with the tran sform ing rule. Rated tap tran sform ing ratio allowable differe nee is0.5%, others shl within 1/10 of tr
12、an sformerresista nee (%), but not more tha n 1%.7)檢查三相變壓器的結(jié)線組別和單相變壓器引出線的極性Check three phase transformer wire series and polarity of single phase transformer output wire.8)測(cè)量繞組連同套管的絕緣電阻Measure the in sulati on resista nee of winding and sleeve.a)絕緣電阻值不應(yīng)低于出廠試驗(yàn)值的70%。In sulati on resista nee shall be n
13、ot less tha n 70% of leave factory testi ng value.b)當(dāng)測(cè)量溫度與產(chǎn)品出廠試驗(yàn)時(shí)溫度不符合時(shí),可按下表?yè)Q算到同一溫度時(shí)的數(shù)值進(jìn)行比較:If any unconformity between measured temperature and leaving factory test ing temperature, convert into same temperature accord ing below table and compare:溫度差TemperatureDiffere neeK51015202530354045505560換算系
14、數(shù)Con verti ngA1.21.51.82.32.83.44.15.16.27.59.211.2Coefficie nt(注:表中K為實(shí)測(cè)溫度減去20C的絕對(duì)值)(Remark: K is the absolute value of measured temperature minus 20 C )c) 當(dāng)測(cè)量絕緣電阻的溫度差不是表中所列數(shù)值時(shí), 其換算系數(shù)按下列公式計(jì)算: when temperature difference of measuring insulation resistance value can not be found in the above table, th
15、e converting formula is :A=1.5K/10當(dāng)實(shí)測(cè)溫度為 20 C以上時(shí):When measured temperature is above 20CR20=AR t當(dāng)實(shí)測(cè)溫度為 20 C以下時(shí):When measured temperature is below 20 CR20=Rt/A(式中:R20-校正到20C時(shí)的絕緣電阻值;Rt-在測(cè)量溫度下的絕緣電阻值)(R20- revise to absolute value of 20C , Rt- is the absolute resistance vale under measuring temperature)9
16、) 交流耐壓試驗(yàn) AC Withstand V oltage Test根據(jù)制造廠提供的技術(shù)資料及業(yè)主的要求決定是否進(jìn)行該項(xiàng)試驗(yàn);如進(jìn)行該項(xiàng) 試驗(yàn)需制造廠提供試驗(yàn)電壓值。 In accordance with the technical documents provided by manufacturer and Clien ts requirements to determine whether to carry out thetest, if do it, the manufacture should provide test voltage value.a) 試驗(yàn)電壓的頻率為 50Hz,電
17、壓波形應(yīng)盡可能接近正弦波形。The testing voltage frequency is 50Hz, voltage wave form better be sine wave.b) 進(jìn)行交流耐壓時(shí) ,非被試側(cè)繞組應(yīng)短接后接地。Carry out AC withstand voltage test, the un-test side of the winding resistance should be earthed.10) 測(cè)量與鐵芯絕緣的各緊固件的絕緣電阻measure the resistance of iron coreinsulation fastening warea) 應(yīng)測(cè)
18、量可接觸到的穿芯螺栓、軛鐵夾件及綁扎鋼帶對(duì)鐵軛、鐵芯及繞組壓環(huán)的絕緣電阻;Measure the touchable penetration bolt, yoke clamp, steel banding yoke, steel core and winding ring insulation resistance.b) 采用 2500V 兆歐表測(cè)量,持續(xù)時(shí)間為 1 分鐘,應(yīng)無(wú)閃絡(luò)及擊穿現(xiàn)象;measuring with 2500 ohmmeter, tine last 1minute, no flashover, no breakdown.c) 當(dāng)軛鐵梁及穿芯螺栓一端與鐵芯相連時(shí),應(yīng)將連接片
19、斷開后進(jìn)行試驗(yàn);When one side of yoke beams and penetration bolts connected with the core, carry out Test after disconnecting the clips.11) 沖擊合閘試驗(yàn) Impact Closing Test在額定電壓下對(duì)變壓器進(jìn)行沖擊合閘試驗(yàn),應(yīng)進(jìn)行 5 次,每次間隔宜為 5 分鐘,無(wú)異?,F(xiàn)象。沖擊合閘試驗(yàn)宜在變壓器高壓側(cè)進(jìn)行;對(duì)中性點(diǎn)接地的電力系統(tǒng),沖擊 試驗(yàn)時(shí)變壓器的中性點(diǎn)必須接地; 發(fā)電機(jī)變壓器組中間連接無(wú)操作斷開點(diǎn)的變壓器, 可不進(jìn)行沖擊合閘試驗(yàn)。Carry out impac
20、t closing test under rated voltage for 5 times every 5 minus, there should be no abnormal phenomenon. Impact closing test shall carry out at high pressure side of transformer. The neutral point must be grounded for power system with neutral grounding. No impact closing test is acceptable for the gen
21、erator transformer assembly without operation disconnection point.12) 檢查相位 Phase Check檢查變壓器的相位必須與系統(tǒng)相位一致。Confirm the transformer and the system phase must be consistent.3. 電纜試驗(yàn) Cable Test1) 絕緣測(cè)試 Insulation Testa) 測(cè)量電纜對(duì)地或?qū)饘倨帘螌娱g和各線芯間的絕緣電阻。Measure the insulation resistance of cable to ground or iron sh
22、ielded layer and cores.b) 對(duì) 1kV 以上電纜采用 2500V 兆歐表。Use 2500V Megohmmeter to test cable of above 1kVc) 對(duì) 0.6/1kV 及以下電纜采用 1000V 兆歐表。Use 1000V Megohmmeter to test cable of 0.6/1Kv and below.2) 直流耐壓及泄漏電流測(cè)量DC Voltage Endurance and DC Leaking Measuring(塑料絕緣電纜包括聚氯乙烯絕緣電纜、聚乙烯絕緣電纜及交聯(lián)聚乙烯絕緣電纜。 聚氯乙烯絕緣電纜產(chǎn)品型號(hào)有 VV 、V
23、LV 等;聚乙烯絕緣及交聯(lián)聚乙烯絕緣電纜 的產(chǎn)品型號(hào)有 YJV 及 YJLV 等。 )Plastic insulation cable including PVC insulation cable, polyethylene insulation cable and cross-linked polyethylene insulation cable電纜額定電壓(U 0)Cable Rated Voltage直流試驗(yàn)電壓DC Test Voltage試驗(yàn)時(shí)間(min)TestingTime3.6kV15kV156kV24kV158.7kV35kV153)試驗(yàn)時(shí),試驗(yàn)電壓可分 46階段均勻升壓,
24、每階段停留1min,并讀取泄漏電流值。測(cè)量時(shí)應(yīng)消除雜電流的影響。During testi ng, the test voltage can be divided into 4-6 steps to in crease voltage uniformly, each step lasts 1 min, and read leakage current value. Eliminate the miscellaneous current in flue nee duri ng measuri ng.4)對(duì)額定電壓為 0.6/1kV的電纜可用1000V或2500V兆歐表測(cè)量導(dǎo)體對(duì)地絕緣電阻代 替直流
25、耐壓試驗(yàn)。0.6/1kV cable, use 1000V or 2500V Megohmmeter to measure the resista nee of con ductor to earth in sulati on resista nee in stead of DC voltage en dura nee test.5)交流單芯電纜的護(hù)層絕緣試驗(yàn)標(biāo)準(zhǔn),按產(chǎn)品技術(shù)條件的規(guī)定進(jìn)行。AC sin gle core cable protect ion layer test sta ndard should be accord ing to tech no logy con diti on
26、.6)電纜主絕緣交流耐壓試驗(yàn)Cable main in sulation AC voltage en dura nee test試驗(yàn)電壓:2U0 ;持續(xù)時(shí)間:60min (U0:電纜額定相電壓)。Test voltage: 2UO, lasting time: 60min (UO: cable rated voltage)7)按產(chǎn)品技術(shù)條件的規(guī)定決定進(jìn)行直流耐壓及泄漏電流測(cè)量或是進(jìn)行電纜主絕緣交流 耐壓試驗(yàn)。Carry out DC voltage en dura nee and leakage curre nt measure or cable main in sulatio n AC vo
27、ltage test accord ing product tech no logy terms and con diti on stipulati on.8)相位檢查 Phase Check電纜接線相序與系統(tǒng)相位一致。Cable connection order is same with system phase4. 交流電機(jī)試驗(yàn)AC Gen erator Test1)測(cè)量繞組的絕緣電阻,使用500V兆歐表,常溫下絕緣電阻值不應(yīng)低于0.5;額定電壓為1kV及以上,在運(yùn)行溫度時(shí)的絕緣電阻值定子繞組不低于每千伏 1,轉(zhuǎn)子繞組不應(yīng)低于每千伏 0.5。Measure wi nding in sula
28、ti on resista nee, use 500v Megohmmeter, in sulati on resista nee valueshall not less than 0.5under normal temperature. Rated voltage is above 1kV,in sulati on resista nee value stator winding is not less tha n 1 /kV un der operati on temperature, stator winding resista nee shall not be less tha n 0
29、.5 /Kv.2)100kW以上的電動(dòng)機(jī)各相繞組直流電阻值相互差別不應(yīng)超過(guò)其最小值的2%,中性點(diǎn)未引出的電動(dòng)機(jī)可測(cè)量線間直流電阻,其相互差別不應(yīng)超過(guò)最小值的1%。測(cè)量時(shí)應(yīng)記錄環(huán)境溫度,以便與出廠試驗(yàn)值相比較。Above 100kW motor, each winding DC resista nee value differe nee shall be not exceed 2% of the mi nimum, without output n eutral point of the motor, measure the DC resista nee betwee n the lines,
30、their mutual differences should not exeeed 1% of the minimum. Reeord the ambient temperature whe n measuri ng in order to eompare with faetory experime ntal data.不平衡率三相實(shí)測(cè)最大值最小值三相最小值100%3 phase measured max value-min valueUn bala need value=x100%3phase min3)檢查定子繞組的極性及其連接應(yīng)正確。中性點(diǎn)未引出者可不檢查極性。Cheek the po
31、larity of the stator windings and conn eeti ons. There can be no eheek ing if the output n eutral point is not available.4)對(duì)于備用發(fā)電機(jī)的試驗(yàn),依據(jù)制造廠提供的試驗(yàn)項(xiàng)目及標(biāo)準(zhǔn)進(jìn)行試驗(yàn)。Test for Stan dby gen erators, accord ing to the test item and sta ndards provided manu faeturer.5. 繼電器調(diào)試 Relay Commissio ning1)調(diào)試前,應(yīng)保證繼電器對(duì)試驗(yàn)電源的要求
32、。電源的波形應(yīng)為正弦波,諧波分量不超過(guò)基波的5%。試驗(yàn)電源的頻率應(yīng)為50Hz。當(dāng)試驗(yàn)電源頻率對(duì)繼電器影響較大時(shí)應(yīng)考慮頻率的正、負(fù)偏差對(duì)試驗(yàn)數(shù)據(jù)的影響,應(yīng)對(duì)試驗(yàn)數(shù)據(jù)進(jìn)行修正。當(dāng)使用直流電 源試驗(yàn)時(shí),電源的波紋系數(shù)要小。一般情況下,波紋系數(shù)K 1%。Before commissioning, ensure relay meets test power requirements. Power should be sinu soidal wave form, the fun dame ntal wave does not exeeed 5% of harm onic wave. The freque
33、ncy of test power should be 50 Hz. When the test freque ncy of power have great in flue nee on relays, positive and n egative deviati on of the test data should be eon sidered, and ame nd test data. When using DC power for test, the corrugated eoeffieie nt is smaller. gen erally, corrugated eoeffiei
34、e nt K 1%.2)使用標(biāo)準(zhǔn)儀表的精度不低于0.5級(jí)。Using sta ndard in strume nt preeisi on is not lower tha n 0.53) 使用專用儀器進(jìn)行調(diào)試時(shí),專用儀器上的電表精度不低于0.5 級(jí)。Using specialized instrument for commissioning, the instrument ammeter accuracy is not lessthan 0.5.4) 繼電器外殼應(yīng)清潔無(wú)灰塵。外殼、玻璃應(yīng)完整,嵌接要良好。外殼與底座結(jié)合應(yīng)緊 密牢固,防塵密封應(yīng)良好,安裝端正。繼電器端子接線應(yīng)牢固可靠。Relay
35、 shell should be clean. Shell, glass should be complete, embedded is good. Shell should be closely combined with the base, dust-protection seal should be good, correct installation. Relay terminal block should be solid and reliable.5) 繼電器內(nèi)部應(yīng)清潔、接線牢固、各部件完好,動(dòng)作靈活、可靠。The relay inner part shall be clean,
36、connection solid, all part is perfect, flexible and liable6) 繼電器的接點(diǎn)檢查: 應(yīng)保證接點(diǎn)接觸良好、 無(wú)抖動(dòng)、 粘住或出現(xiàn)火花等異常現(xiàn)象, 并 有足夠的壓力。Relay contact point inspection: ensure contact point is good, jitter-free, no stick and sparkabnormal phenomenon, and sufficient pressure.7) 電磁式繼電器其動(dòng)作值應(yīng)測(cè)量繼電器的沖擊動(dòng)作值。然后平穩(wěn)下降測(cè)量繼電器的返 回值。 對(duì)于欠量動(dòng)作的繼
37、電器應(yīng)將繼電器升到額定值, 然后平穩(wěn)下降至動(dòng)作值。 電子 組合式繼電器按制造廠商提供的技術(shù)資料中要求進(jìn)行調(diào)試。 Electromagnetic relay operating value shall be the impact operating value. Then steady decline measuring the return value of measuring relays. Increase the value to rated for the unreached, and then decrease steadily to operating value. Commiss
38、ion the electronic combined Relay according to technical information provided by manufacturers.8) 檢查電磁式繼電器的動(dòng)作、返回值及返回系數(shù)應(yīng)符合產(chǎn)品技術(shù)要求。Check Electromagnetic relay operation, return value and return coefficient shall comply with product technology requirement.9) 復(fù)核繼電器的動(dòng)作值。Re-check relay operation value.10)
39、校核、調(diào)整熱繼電器的設(shè)定值,其動(dòng)作值應(yīng)符合被保護(hù)設(shè)備的容量。Check and commission set value of thermal relay, the operation value shall comply with the capacity of protected equipment.11) 絕緣電阻的測(cè)定:額定電壓為 100V 及以上者,使用 1000V 兆歐表;額定電壓為 100V 以下者,使用500V兆歐表。端子對(duì)底座和磁導(dǎo)體的絕緣電阻應(yīng)大于50MQ。各線圈對(duì)觸點(diǎn)及各觸點(diǎn)間的絕緣電阻應(yīng)大于50MQ。各線圈間的絕緣電阻應(yīng)大于10MQ。由電子元、器件組成的綜合繼電器不進(jìn)行
40、絕緣電阻的測(cè)定。Insulation Resistance meauring: rated voltage of 100 V and above, use of 1000 V Megohmmeter; rated voltage below 100 V, use 500 V Megohmmeter. The loop contact pointand each con tact point in sulati on resista nee should be more tha n 50MQ . The coil and con tactson the con tacts betwee n th
41、e in sulati on resista nee should be more tha n 50twee n the coil MQ . Beinsulation resistance should be greater than 10 MQ .No measure to insulation resistancecomprehensive relay composed of electronic device.1.112) 電磁式繼電器進(jìn)行沖擊試驗(yàn): 電壓型繼電器其沖擊電壓應(yīng)為該繼電器額定電壓的倍;電流型繼電器其沖擊電流應(yīng)為保護(hù)安裝處最大故障電流。沖擊試驗(yàn)時(shí),接點(diǎn)不 應(yīng)產(chǎn)生振動(dòng)和鳥啄現(xiàn)象
42、。Impact test to electromagnetic relay: the impact voltage of voltage relay s voltage is 1.1 times of its rated voltage, impact current of current relays should be the Max fault current of the protection installed place. During impact test, no vibration and bird pecking phenomenon at contact point.13
43、) 主變壓器保護(hù)裝置、測(cè)控裝置等各種類型的自動(dòng)保護(hù)裝置的調(diào)試方法和調(diào)試接線, 按廠商提供的產(chǎn)品技術(shù)資料進(jìn)行調(diào)試。Main transformer protective device, detective device etc, all self-protective device commissioning method and commissioning contact shall comply with technology information provided by manufacturer.14) 對(duì)多功能綜合保護(hù)繼電器的數(shù)碼顯示部分應(yīng)完好,刻度清晰、準(zhǔn)確。Multi-functi
44、onal comprehensive protective relay digital display part shall be perfect, Calibration clear and accurate.15) 按產(chǎn)品的技術(shù)性能,輸入相應(yīng)的參數(shù)值,檢驗(yàn)其功能是否符合產(chǎn)品的技術(shù)標(biāo)準(zhǔn)。Input parameter values according to product technology performance, check if the functions comply with technology standard.16) 按設(shè)計(jì)的整定值,檢驗(yàn)繼電器實(shí)際動(dòng)作值。Check act
45、ual operation value of the relay according to set value.17) 對(duì)過(guò)量參數(shù)值由低值逐漸升至動(dòng)作值,欠量參數(shù)值由額定值降至動(dòng)作值。Excessive parameters, increase gradually from low value to operation value, less of parameter values decrease from rated value to operation value.18) 在未采取可靠的措施前,不得觸摸繼電器內(nèi)部電路板,以免靜電損壞電路板。Before no reliable measu
46、res taken, forbid to touch the internal circuit boards to prevent any damage.6. 傳動(dòng)試驗(yàn) Transmission Test1) 主變壓器進(jìn)線開關(guān)、隔離開關(guān)、接地開關(guān)分、合閘操作;Main transformer input switch, isolation switch, earthing switch turn on/off operation;2) MCC (電動(dòng)機(jī)控制中心)系統(tǒng)分、合閘操作;MCC system turn on/off operation;3) 變壓器保護(hù)等動(dòng)作跳閘及信號(hào)的傳動(dòng)試驗(yàn); Tr
47、ansformer protection trip and signal transmission test;MCC wire cabinet4) MCC (電動(dòng)機(jī)控制中心)饋線柜動(dòng)作跳閘及信號(hào)的傳動(dòng)試驗(yàn); protection trip and signal transmission test;5)備用電源自投的傳動(dòng)試驗(yàn); Spare power independent transmission test;6)測(cè)量、計(jì)量回路的傳動(dòng)試驗(yàn)及其它傳動(dòng)試驗(yàn); Measuring and recording loop transmission test and other transmission t
48、est;9)上述傳動(dòng)試驗(yàn)應(yīng)準(zhǔn)確、可靠;二次回路絕緣良好。 Above transmission tests should be accurate and reliable; loop should be well isolated.7. UPS (不間斷電源)調(diào)試 UPS Commissioning1)UPS (不間斷電源)裝置主機(jī)按制造廠技術(shù)資料要求進(jìn)行調(diào)試。The commissioning of UPS mainframe should be according to Manu facturer s technical specification documents.2)UPS (不間斷
49、電源)裝置蓄電池絕緣電阻應(yīng)符合產(chǎn)品技術(shù)條件,并按制造廠技術(shù)條件進(jìn)行充放電;充電電壓應(yīng)符合產(chǎn)品技術(shù)條件。10 小時(shí)放電應(yīng)達(dá)到 100%放電率。Storage battery isolation resistance of the UPS should comply with technical specification and should be discharged accordingly; charge voltage should comply with technical specification. 10-hour discharge should reach 100% discha
50、rging rate.8. 電氣受、送電 Electric Apparatus Receiving and Supplying Power1)電氣受、送電,遵循先高壓(電源 )側(cè)后低壓 (負(fù)荷 )側(cè),斷電時(shí),先斷低壓側(cè)(負(fù)荷)側(cè),后高壓 (電源 )側(cè)。 Receiving and supplying power should be from high voltage side and then lower side; breaking power should be from lower voltage side and then higher.2)為保證安全在變壓器受電前將盤柜內(nèi)所有開關(guān)置于
51、斷開位置All the switchesshould be kept Off before receiving power in order to guarantee the safety.3)在額定電壓下對(duì)變壓器沖擊試驗(yàn) 5 次,每次間隔時(shí)間為 5min ,無(wú)異?,F(xiàn)象 Carry out impacting test 5 times every 5 min under rating voltage, there should be no abnormal situations.4)兩段受電后,在母聯(lián)柜母聯(lián)開關(guān)一、二次核相。 After second phase receiving, check busbar switch phase.5)進(jìn)行并列運(yùn)行及進(jìn)線柜、母聯(lián)柜聯(lián)鎖試驗(yàn)Carry out shun
溫馨提示
- 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 2024年物業(yè)管理與維護(hù)合作協(xié)議3篇
- 2024新媒體項(xiàng)目協(xié)作協(xié)議簡(jiǎn)約版版B版
- 2024年貨物銷售合同協(xié)議書
- 2024年物業(yè)維修服務(wù)協(xié)議(含裝修)3篇
- 2024微信小程序功能定制開發(fā)服務(wù)合同3篇
- 2024年股權(quán)轉(zhuǎn)讓協(xié)議(復(fù)雜版)
- 2024政府與華為簽訂的環(huán)保產(chǎn)業(yè)合作協(xié)議3篇
- 2024年貨車非官方過(guò)戶銷售協(xié)議書版
- 2024新型智能家居產(chǎn)品研發(fā)與技術(shù)服務(wù)協(xié)議
- 2024年藝人經(jīng)紀(jì)公司與藝人獨(dú)家代理合同
- 齊魯名家 談方論藥智慧樹知到期末考試答案2024年
- 南京工業(yè)大學(xué)橋梁工程課程設(shè)計(jì)
- 職業(yè)健康監(jiān)護(hù)技術(shù)規(guī)范
- 水不同溫度的熱焓值
- 小品劇本《超級(jí)招聘》
- 空氣壓縮機(jī)檢驗(yàn)原始記錄表
- 叉車部件的涂裝工藝及體系
- DB32∕T 3261-2017 水利工程預(yù)拌混凝土應(yīng)用技術(shù)規(guī)范
- 物理學(xué)習(xí)的8種思考方式
- 中國(guó)風(fēng)圍棋對(duì)弈雅致文藝教育培訓(xùn)活動(dòng)策劃版
- 基于51單片機(jī)的簡(jiǎn)易計(jì)算器時(shí)間顯示(LCD1602顯示)
評(píng)論
0/150
提交評(píng)論