1、南京工程學(xué)院畢業(yè)設(shè)計(jì)說(shuō)明書(論文)畢業(yè)設(shè)計(jì)說(shuō)明書(論文)中文摘要上海某賓館空調(diào)系統(tǒng)設(shè)計(jì)本設(shè)計(jì)是上海某賓館空調(diào)系統(tǒng)設(shè)計(jì),該場(chǎng)所共十三層,總建筑面積約11279 m2??照{(diào)設(shè)計(jì)中,整棟大樓均采用風(fēng)機(jī)盤管加新風(fēng)系統(tǒng),辦公室、會(huì)議室等采用臥式暗裝風(fēng)機(jī)盤管。每層設(shè)置一臺(tái)吊頂式空氣處理機(jī)組,安裝在走廊的吊頂內(nèi)。將室外新風(fēng)處理到室內(nèi)空氣焓值,不承擔(dān)室內(nèi)負(fù)荷。臥式暗裝風(fēng)機(jī)盤管采用雙層百葉風(fēng)口側(cè)送風(fēng),新風(fēng)處理到室內(nèi)焓值后一并送出,回風(fēng)口采用單層活動(dòng)百葉風(fēng)口下部回風(fēng)。空調(diào)用制冷機(jī)房設(shè)在屋頂,選用螺桿式冷水機(jī)組。關(guān)鍵詞 風(fēng)機(jī)盤管加新風(fēng)系統(tǒng) 南京工程學(xué)院畢業(yè)設(shè)計(jì)說(shuō)明書(論文)畢業(yè)設(shè)計(jì)說(shuō)明書(論文)外文摘要title
2、the central air-conditioning system design of an hotel in shanghai abstractthis design is the engineering of air conditioning system in shanghai hotel.the place of thirteen floors with a total construction area is about 11279 square meters.in the air conditioning design, the whole building are used
3、fan coil plus fresh air system.offices, meeting rooms ,ect. use horizontal concealed fan coil. on each floor, set an air handling unit. installation of the ceiling is in the corridor. the fresh air to indoor is enthalpy valued deal and do not take indoor load. cassette fan coil is surrounded by a wi
4、nd coming with air and the middle back.fresh air diffuser with a square top level delivery. horizontal concealed fan coil using double-side air outlet louvers, the new indoor air enthalpy value processing to be sent. return air vent louvers using the lower layer activities.air conditioning refrigera
5、tion room is located on the roof, with screw chiller.key words: fan coil plus fresh air system 南京工程學(xué)院畢業(yè)設(shè)計(jì)說(shuō)明書(論文)目錄前 言1第一章 原始資料2 1.1 建筑概況2第二章 設(shè)計(jì)規(guī)范及依據(jù)32.1設(shè)計(jì)范圍32.2 設(shè)計(jì)依據(jù)3第三章 設(shè)計(jì)參數(shù)43.1 室內(nèi)設(shè)計(jì)參數(shù)43.2 室外設(shè)計(jì)參數(shù)43.3 圍護(hù)結(jié)構(gòu)設(shè)計(jì)參數(shù)4第四章. 空調(diào)方案比較54.1 冷熱源分析54.2 空調(diào)系統(tǒng)方案的比較與選擇74.3 空調(diào)風(fēng)系統(tǒng)的選擇74.4 空調(diào)水系統(tǒng)方案的選擇8第五章 負(fù)荷計(jì)算95.1 負(fù)荷計(jì)算95.2 濕
6、負(fù)荷計(jì)算125.3 新風(fēng)負(fù)荷計(jì)算12第六章. 空氣熱濕處理計(jì)算及空調(diào)設(shè)備選型186. 1 半集中式空調(diào)系統(tǒng). 196.2 半集中式系統(tǒng)的設(shè)備選型20第七章 氣流組織計(jì)算237.1 側(cè)送氣流組織237.1.2側(cè)送風(fēng)口選擇計(jì)算24第八章. 空調(diào)冷熱源設(shè)備選型258.1 冷源的確定258.2 冷水機(jī)組設(shè)備選型25 8. 3 熱源的選擇26第九章. 空調(diào)風(fēng)道設(shè)計(jì)計(jì)算與布置279.1 風(fēng)管水力計(jì)算27第十章. 空調(diào)水系統(tǒng)管路設(shè)計(jì)3010.1 冷水水力計(jì)算30第十一章. 空調(diào)水系統(tǒng)設(shè)備選型3511.1 冷凍水泵的選型3511.2 冷卻水泵的選型3611.3 冷卻塔的選型3711.4 膨脹水箱的選型3711
7、.5 集水器和分水器38 致 謝.39參考文獻(xiàn).40附 錄.41風(fēng)管水力計(jì)算表. .41水管水力計(jì)算表.44負(fù)荷計(jì)算書.53前言 國(guó)內(nèi)經(jīng)濟(jì)的高速發(fā)展催使大型賓館等的不斷興起,為商用空調(diào)撐起巨大的市場(chǎng)空間??照{(diào)在世界上已有百年的發(fā)展歷史,在中國(guó)也有20多年的應(yīng)用時(shí)間。然而真正引起國(guó)內(nèi)企業(yè)關(guān)注還是近幾年的事。目前國(guó)內(nèi)市場(chǎng)中央空調(diào)領(lǐng)域競(jìng)爭(zhēng)己進(jìn)入白熱化階段。賓館是人們生活的一個(gè)重要場(chǎng)所,因此室內(nèi)空氣的品種、溫度、濕度對(duì)人體的影響較大,這也是人們比較關(guān)注的問(wèn)題。為了保證良好的室內(nèi)辦公環(huán)境,滿足工作人員對(duì)舒適和衛(wèi)生的要求。為此,現(xiàn)特為上海某賓館設(shè)計(jì)一套空調(diào)系統(tǒng)。第一章 原始資料1.1 建筑概況本工程為上海
8、市徐匯區(qū)某賓館建筑中央空調(diào)系統(tǒng)設(shè)計(jì),該建筑層數(shù)為13層(架空層一層),附屬用房6-7層,地下室為1層??偨ㄖ娣e為11279平米左右,總用地面積2295.8平米,空調(diào)面積大約為5697平米,功能上要求有大廳、辦公室、客房(小戶型、中戶型)、配電房,頂層為機(jī)房。客房統(tǒng)一規(guī)定每房間2人。地下室層高3.0m,一二層層高3.6m,其余各層層高3.3米。第二章 設(shè)計(jì)規(guī)范及依據(jù)2.1設(shè)計(jì)范圍根據(jù)所提供的建筑圖紙和文字資料,詳細(xì)地了解房間的使用功能與特點(diǎn),本次畢業(yè)設(shè)計(jì)為整棟大樓暖通空調(diào)系統(tǒng)工程設(shè)計(jì)。2.2 設(shè)計(jì)依據(jù)1 民用建筑供暖通風(fēng)與空氣調(diào)節(jié)設(shè)計(jì)規(guī)范 gb50736-20122 采暖通風(fēng)與空調(diào)設(shè)計(jì)規(guī)范 g
9、b50019-20033 公共建筑節(jié)能設(shè)計(jì)標(biāo)準(zhǔn) gb50018920054 暖通空調(diào)制圖標(biāo)準(zhǔn) gb/t50114-20105 通風(fēng)與空調(diào)工程施工質(zhì)量驗(yàn)收規(guī)范 gb50243-20116 實(shí)用供熱空調(diào)設(shè)計(jì)手冊(cè)第二版中國(guó)建筑工業(yè)出版社, 20077 通風(fēng)管道技術(shù)規(guī)程 jgj141-20048 公共建筑節(jié)能設(shè)計(jì)標(biāo)準(zhǔn) (gb50189-2005)9 通風(fēng)與空調(diào)工程施工質(zhì)量驗(yàn)收規(guī)范 gb50243200210 全國(guó)民用建筑工程設(shè)計(jì)技術(shù)措施 (暖通空調(diào) .動(dòng)力)(2009年版)11 全國(guó)民用建筑工程設(shè)計(jì)技術(shù)措施 (防空地下室)(2009年版)第三章 設(shè)計(jì)參數(shù)3.1 室內(nèi)設(shè)計(jì)參數(shù)本次工程設(shè)計(jì),根據(jù)相關(guān)規(guī)范及
10、設(shè)計(jì)手冊(cè),查得室內(nèi)空氣計(jì)算參數(shù),見表3-1所示。表3-1 室內(nèi)設(shè)計(jì)參數(shù)表房間室內(nèi)溫度() 相對(duì)濕度()噪聲等級(jí)db(a) 工作區(qū)風(fēng) 速m/s新風(fēng)標(biāo)準(zhǔn)m3/h.p 夏季 冬季 夏季 冬季辦公室2518604035400.20.430商業(yè)2518604035400.20.430會(huì)議2518604035400.20.430客房2518604035400.20.4303.2 室外設(shè)計(jì)參數(shù)本設(shè)計(jì)工程,根據(jù)課程設(shè)計(jì)指南,查得室外空氣計(jì)算參數(shù),見表3-2所示。表3-2 上海市夏季室外設(shè)計(jì)參數(shù)季節(jié)干球溫度濕球溫度相對(duì)濕度%室外日平均溫度大氣壓mbar風(fēng)速m/s空調(diào)通風(fēng)夏季32.133287429.61004.
11、501.83.3 圍護(hù)結(jié)構(gòu)設(shè)計(jì)參數(shù)設(shè)計(jì)時(shí)考慮到節(jié)能性,使用了保溫墻體和保溫窗體材料。圍護(hù)結(jié)構(gòu)參數(shù): (1)屋面:根據(jù)所給圖紙,屋面結(jié)構(gòu)是剛性防水屋面,保溫材料是水泥膨脹珍珠巖換位爐渣保溫,厚度為60mm。 屋面的傳熱系數(shù)取0.49(w/k)。(2)外墻:結(jié)構(gòu)形式統(tǒng)一為框架-剪力墻結(jié)構(gòu)。大樓的外墻為厚度為200mm的紅磚墻,墻外表面為水泥砂漿抹灰加淺色噴漿,墻為厚為70mm的加氣混凝土保溫層,內(nèi)粉刷加油漆。 傳熱系數(shù)0.54(w/k)。3)外窗:雙層鋼窗,規(guī)定窗戶統(tǒng)一高度為2m,厚度為3mm,內(nèi)有活動(dòng)百葉簾作為內(nèi)遮陽(yáng)。 其傳熱系數(shù)為2.60(w/k)。第四章 空調(diào)方案比較4.1 冷熱源分析本建筑
12、主要為各類不同功能辦公室以及客房等?,F(xiàn)初步考慮采用水冷和風(fēng)冷兩種冷源系統(tǒng)。4.1.1 初步擬定冷源方案方案一:水冷螺桿式冷水機(jī)組水冷螺桿式冷水機(jī)組的冷量一般較大,可達(dá)到100kw200kw,通??晒┮粭潣?。其主要控制參數(shù)為制冷性能系數(shù),額定制冷量,輸出功率以及制冷劑類型等等。螺桿式冷水機(jī)組較適用于大中型空調(diào)制冷系統(tǒng)。方案二:風(fēng)冷模塊式冷水機(jī)組空氣是風(fēng)冷模塊式冷熱水機(jī)組的冷熱源,制冷或制熱是利用電驅(qū)動(dòng)來(lái)進(jìn)行的,可以一年四季運(yùn)行。它是一種獨(dú)立完整機(jī)組,充分利用自然空氣,節(jié)省能源。除了可以滿足建筑物夏天制冷,冬天制熱要求外,還可以全天供應(yīng)生活熱水,極大的方便了人們的生活,具有設(shè)備利用率高的特點(diǎn)。4.
13、1.2 冷源系統(tǒng)方案對(duì)比(1) 機(jī)組的制冷性能 水冷機(jī)組初投資低,應(yīng)用范圍廣,造價(jià)也低,機(jī)組壽命長(zhǎng);其技術(shù)發(fā)展完善,在目前是大型賓館建筑應(yīng)用最廣泛的系統(tǒng)。其冷熱源一般集中設(shè)置,體積相對(duì)較小,占地小,運(yùn)行及管理方便。水冷機(jī)組適用于大中型建筑,在這里,可以優(yōu)先考慮水冷機(jī)組。(2)機(jī)組設(shè)備的價(jià)格風(fēng)冷機(jī)組單價(jià)比水冷機(jī)組高出約25% - 35%,在他們制冷量相同的時(shí)候。但從整體角度來(lái)說(shuō),水冷機(jī)組需要冷卻水泵、冷卻塔以及冷卻水系統(tǒng)管道等等。加上這些造價(jià),兩者的總價(jià)相差是不大的。(3)運(yùn)行成本比較一般來(lái)說(shuō),水冷機(jī)組制冷效率高,冷量大,機(jī)組運(yùn)行的時(shí)候耗電量較小。并且當(dāng)水冷式冷水機(jī)組與風(fēng)冷機(jī)組制冷量相同的時(shí)候,
14、水冷式機(jī)組的總體耗電量要比風(fēng)冷式機(jī)組耗電量節(jié)約30。水冷機(jī)組效率調(diào)幅、又有節(jié)能環(huán)保的效果,并且機(jī)組本身就采用水來(lái)冷卻的形式,運(yùn)行費(fèi)用只有風(fēng)冷機(jī)組的60%左右。(4) 機(jī)組噪聲 一般來(lái)說(shuō),水冷機(jī)組系統(tǒng)機(jī)房的噪聲是要比風(fēng)冷機(jī)組系統(tǒng)機(jī)房的噪聲要小的。4.1.3 熱源方案的選擇 關(guān)于熱源的選擇,燃?xì)忮仩t耗能高,供暖熱量高,對(duì)鍋爐的耐壓要求高。而熱水供暖,溫度雖然低一點(diǎn),但熱水泵往外輸送熱水,不需要鍋爐自身提供較高的壓力,耐壓要求不是很高,從根本上提高了鍋爐的壽命。而賓館建筑需要很大程度上的熱水供應(yīng),因此使用燃油熱水鍋爐是最佳選擇。4.2 空調(diào)系統(tǒng)方案的比較與選擇現(xiàn)如今在我國(guó)廣泛應(yīng)用的系統(tǒng)按介質(zhì)分類大致
15、可分為以下幾種: (1) 全水系統(tǒng):利用水來(lái)承擔(dān)室內(nèi)的熱濕負(fù)荷的空調(diào)系統(tǒng),這種系統(tǒng)占建筑面積小。這種系統(tǒng)風(fēng)機(jī)盤管運(yùn)行時(shí)有噪音,影響室內(nèi)人員。對(duì)于室內(nèi)空氣環(huán)境品質(zhì)不高的房間,可以采用全水系統(tǒng)。 (2)全空氣系統(tǒng):運(yùn)行時(shí)冷熱介質(zhì)不進(jìn)入被空調(diào)房間,而只進(jìn)入空調(diào)機(jī)房。因此,房間內(nèi)的冷量或熱量完全是由空氣作為介質(zhì)提供的。全空氣系統(tǒng)需要的空氣量多,適用于一些大空間,因而風(fēng)道斷面尺寸較大。適用于一些體育館、影劇院、大劇院之類。(3)空氣水系統(tǒng):室內(nèi)的負(fù)荷是由空氣和水作為介質(zhì)來(lái)承擔(dān)的??諝饨鉀Q房間新風(fēng)量的問(wèn)題,而水則是通過(guò)房間里的空氣處理設(shè)備承擔(dān)房間里的冷熱量以及濕負(fù)荷。應(yīng)用該類型系統(tǒng)的例子是目前廣泛采用的風(fēng)
16、機(jī)盤管加新風(fēng)系統(tǒng)。綜上所述,結(jié)合實(shí)際的空調(diào)建筑可以看出半集中式系統(tǒng)適用于房間面積大但風(fēng)管不易布置;半集中式系統(tǒng)節(jié)能,靈活性好,而且可根據(jù)各室內(nèi)負(fù)荷進(jìn)行調(diào)節(jié),不管在夏季還是冬季都可以使用。本建筑屬于賓館,可采用風(fēng)機(jī)盤管加新風(fēng)空調(diào)系統(tǒng)。4.3 空調(diào)風(fēng)系統(tǒng)的選擇風(fēng)機(jī)盤管與新風(fēng)共同來(lái)承擔(dān)房間的顯熱冷負(fù)荷和濕負(fù)荷(包括新風(fēng)負(fù)荷),關(guān)于分配負(fù)荷通常會(huì)采用以下方案:新風(fēng)處理到室內(nèi)空氣的焓值,而風(fēng)機(jī)盤管承擔(dān)室內(nèi)人員、設(shè)備冷負(fù)荷和建筑維護(hù)結(jié)構(gòu)冷負(fù)荷。室外新風(fēng)被冷卻處理到機(jī)器露點(diǎn);此點(diǎn)的溫度根據(jù)設(shè)計(jì)的室內(nèi)狀態(tài)點(diǎn)的焓只限于相對(duì)濕度90%線的交點(diǎn)確定。因?yàn)楸窘ㄖ儆诖笮唾e館建筑,人員密度小,各房間的熱、濕負(fù)荷都很小,
17、所需要的新風(fēng)量也不大,所以可以選擇此方案。在本建筑工程中,可以根據(jù)每層的風(fēng)量與冷量(第五章負(fù)荷計(jì)算中給出),選擇出新風(fēng)機(jī)組,在每層合適的位置暗裝新風(fēng)機(jī)組,獨(dú)立處理新風(fēng)到室內(nèi)空氣,風(fēng)機(jī)盤管承擔(dān)室內(nèi)的負(fù)荷。4.4 空調(diào)水系統(tǒng)方案的選擇在這里水系統(tǒng)采用了閉式系統(tǒng),膨脹水箱設(shè)置在最高點(diǎn),這樣不單單達(dá)到清潔衛(wèi)生的效果,并且不需要克服系統(tǒng)靜水壓頭,并且水泵耗電較小,節(jié)約能源。干管的布置采用水平式布管,一級(jí)泵,選用異程式,水泵采用變流量系統(tǒng)。第五章 負(fù)荷計(jì)算5.1 負(fù)荷計(jì)算5.1.1 冷負(fù)荷構(gòu)成負(fù)荷計(jì)算包括室內(nèi)冷負(fù)荷計(jì)算、熱負(fù)荷計(jì)算、濕負(fù)荷計(jì)算和新風(fēng)負(fù)荷計(jì)算。5.1.2 外墻和屋面冷負(fù)荷外墻和屋面瞬變傳熱引
18、起的逐時(shí)冷負(fù)荷是由于日射和室外氣溫綜合作用所造成的,可按下式(5-1)計(jì)算: (5-1)式中 5.1.3 內(nèi)圍護(hù)結(jié)構(gòu)的傳熱冷負(fù)荷當(dāng)相鄰房間為非空調(diào)房間時(shí),并且通風(fēng)良好,通過(guò)內(nèi)墻和樓板的溫差傳熱而產(chǎn)生的冷負(fù)荷可按式(5-2)計(jì)算: (5-2) 式中 當(dāng)鄰室存在一定發(fā)熱量,房間各種內(nèi)圍護(hù)結(jié)構(gòu)的溫差傳熱而產(chǎn)生的冷負(fù)荷此時(shí)可當(dāng)作穩(wěn)定傳熱,它不隨時(shí)間的變化而變化,可按式(5-3)計(jì)算: (5-3)式中 鄰室溫升,。5.1.4 外窗的溫差傳熱冷負(fù)荷外窗溫差傳熱形成的計(jì)算時(shí)刻冷負(fù)荷可按式(5-4)計(jì)算: (5-4)5.1.5 外窗的太陽(yáng)輻射冷負(fù)荷外窗太陽(yáng)輻射形成的計(jì)算時(shí)刻冷負(fù)荷可按式(5-5)計(jì)算: (5-
19、5)5.1.6 人體顯熱冷負(fù)荷人體顯熱散熱形成的計(jì)算時(shí)刻冷負(fù)荷,可按式(5-6)計(jì)算: (5-6) 5.1.7 照明散熱冷負(fù)荷燈具散熱形成的計(jì)算時(shí)刻冷負(fù)荷可按式(5-7)計(jì)算: (5-7)式中 同時(shí)使用系數(shù),當(dāng)缺少實(shí)測(cè)數(shù)據(jù)時(shí),可取0.6-0.8; 燈具的安裝功率,w; tt時(shí)刻燈具散熱的冷負(fù)荷系數(shù)。5.1.8 其他室內(nèi)散熱量 人體顯熱散熱引起的冷負(fù)荷可按式(5-8)計(jì)算: (5-8)人體潛熱散熱引起的冷負(fù)荷可按式(5-9)計(jì)算: (5-9)式中 不同室溫和勞動(dòng)性質(zhì)成年男子潛熱散熱量,w;由暖通空調(diào)查得辦公室=45w。第 71 頁(yè)冷負(fù)荷計(jì)算書見附表。5.2 濕負(fù)荷計(jì)算5.2.1 房間濕負(fù)荷的構(gòu)成
20、(1)人體散濕量。(2)新風(fēng)濕負(fù)荷。5.2.2 濕負(fù)荷的計(jì)算濕負(fù)荷是指空調(diào)房間的濕源(人體散濕、敞開水表面散濕和地面積水等)向室內(nèi)的散濕量,也就是維持室內(nèi)含濕量恒定需從房間出去的濕量。人體散濕量可按式(5-10)計(jì)算: (5-10)5.3 新風(fēng)負(fù)荷計(jì)算5.3.1 空調(diào)系統(tǒng)的新風(fēng)量依據(jù)以下三個(gè)原則確定:5.3.2 空調(diào)新風(fēng)冷負(fù)荷的計(jì)算夏季空調(diào)新風(fēng)冷負(fù)荷按式(5-11)計(jì)算: (5-11) 現(xiàn)已2層管理辦公室為例計(jì)算負(fù)荷如下:北外墻冷負(fù)荷qc()=ak(tc()+td)kk-tr k 吸收系數(shù)修正值,取k=0.97; k 外表面換熱系數(shù)修正值,取k=0.94;表3.1北外墻逐時(shí)冷負(fù)荷時(shí)間89101
21、1121314151617181920tc()34.233.933.533.232.932.832.933.133.433.934.434.934.2t d-0.8k a0.54k p0.94t,c()30.430.229.829.529.329.229.329.529.730.230.631.1t r 26t4.44.23.83.53.33.23.33.53.7.4.24.65.1k0.92a22.32qc()22.920202124.729.435.142.650.257.765.270.975.6北外窗冷負(fù)荷(1)北外窗瞬時(shí)傳熱冷負(fù)荷qc() = cw kw aw ( tc() + td
22、 tr) 式中 tc() 外玻璃窗的冷負(fù)荷溫度的逐時(shí)值,由暖通空調(diào)附錄2-10查得; cw 玻璃窗傳熱系數(shù)的修正值;由暖通空調(diào)附錄2-9查得; 根據(jù)a i = 8.7 w/(k),a o=18.62w/(k),由文獻(xiàn)4查得k=3w(/k),對(duì)金屬框雙層窗應(yīng)乘1.2的修正系數(shù)。玻璃窗冷負(fù)荷計(jì)算溫度也查文獻(xiàn)4t c(t)表3.2 北外窗瞬時(shí)傳熱冷負(fù)荷時(shí)間891011121314151617181920tc()27.928.12929.930.831.531.932.232.23231.630.829.9t d126.926.92828.929.830.530.931.231.23130.629.8
23、 28.9t r26t-0.12.111.92.85.33.94.24.243.62.81.9kw3.6a w14.04qc()251.1318.3428.8500.7543.2558.2535.8476.5402.8422.2364.79985.9北外窗日射得熱冷負(fù)荷 * aw* cs* ci* djmax* 式中 (由附錄2-15查得雙層鋼窗有效面積系數(shù)ca=0.75,由附錄2-13查得遮擋系數(shù)cs=0.516,由附錄2-14查得遮陽(yáng)系數(shù)ci=0.5,再由附錄2-12查得緯度30時(shí),北向日射得熱因數(shù)最大值=174w/,再由2-17查得北區(qū)有內(nèi)遮陽(yáng)的玻璃窗冷負(fù)荷系數(shù)逐時(shí)值clq)。由以上公式
24、計(jì)算逐時(shí)進(jìn)入玻璃日射得熱引起的冷負(fù)荷,列入下表中:表3.3北外窗日射得熱引起的冷負(fù)荷時(shí)間891011121314151617181920clq0.40.510.580.720.840.80.620.450.320.240.160.10.09174cc,s0.516a w10.53qc()3784255486807947565864253022271519485人員散熱引起的冷負(fù)荷辦公屬極輕勞動(dòng),查表知,當(dāng)室溫為25時(shí),每人散發(fā)的顯熱和潛熱量分別為60.5w和773.3w,由文獻(xiàn)4查取群集系數(shù)為0.93,由附錄2-23查得人體顯熱散熱冷負(fù)荷系數(shù)逐時(shí)值(注意:9:00為人體進(jìn)入室內(nèi)后的第一個(gè)小時(shí)數(shù)
25、)人員顯熱散熱引起的冷負(fù)荷計(jì)算式為:qc(t)=qs* n* *clq clq 人體顯熱散熱冷負(fù)荷系數(shù),計(jì)算時(shí)應(yīng)注意其值為人員進(jìn)入房間時(shí)算起到計(jì)算時(shí)刻的時(shí)間;人體潛熱散熱引起的冷負(fù)荷計(jì)算公式:qc=ql*n*表3.8 人員散熱引起的負(fù)荷時(shí)間89101112131415161718:00clq0.530.640.620.690.740.770.80.830.850.870.89qs60.5n20.8qc()196112197. 376 433466300 334356479 201.5ql73.3qc1363.38合計(jì)115.2115.2254.8264269.5273.2275278.7280
26、.5201.6142.8照明負(fù)荷熒光燈 qc() = 1000 n1 n2 n clq 表4.9照明負(fù)荷時(shí)間89101112131415161718clq0.90.910.910.930.930.940.950.950.950.960.96n11.21.21.21.21.21.21.21.21.21.21.2n20.80.80.80.80.80.80.80.80.80.80.8n200200200200200200200200200200200qc()17.717.7198.1209.9218.8224.7233.6239.5245.4248.485.7設(shè)備冷負(fù)荷設(shè)備的顯熱散熱冷負(fù)荷系數(shù)由文獻(xiàn)
27、4查得。在表中找出設(shè)備連續(xù)使用10小時(shí)時(shí)對(duì)應(yīng)的系數(shù)。冷負(fù)荷的計(jì)算公式: =表.設(shè)備冷負(fù)荷時(shí)間89101112131415161718散熱冷負(fù)荷系數(shù)0.330.410.460.550.620.680.720.760.790.810.84面積80.1880.1280.1880.1880.1880.1880.1880.1880.1880.1880.18單位面積負(fù)荷2020202020202020202020電動(dòng)機(jī)負(fù)荷系數(shù)11111111111同時(shí)使用系數(shù)0.80.80.80.80.80.80.80.80.80.80.8q2.62.613.519.223.626.628.83132.834.124設(shè)備
28、冷負(fù)荷最大值出現(xiàn)在17:00,最大值為41.4w。新風(fēng)負(fù)荷夏季空調(diào)新風(fēng)冷負(fù)荷按下式計(jì)算qc.0=m0(h0-hr)q=ma*(h0-hr)=1.2*30/3600*20*(90-61.5)=5.7kw 內(nèi)維護(hù)結(jié)構(gòu)冷負(fù)荷:,式中 內(nèi)墻及內(nèi)門的附加溫升均取3,計(jì)算如下:內(nèi)墻的冷負(fù)荷:q=1.18*(9.71*3.6-0.9*2.1)*(30.4+3-26)=288.73w內(nèi)門冷負(fù)荷:q=2.5*0.9*2.1*(30.4+3-26)=33.1w第六章. 空氣熱濕處理計(jì)算及空調(diào)設(shè)備選型6.1 半集中式空調(diào)系統(tǒng) 本工程為賓館建筑,對(duì)于這類排風(fēng)量少,要求舒適的房間,可采用風(fēng)機(jī)盤管加新風(fēng)空調(diào)系統(tǒng),它具有投
29、資少,使用靈活性高等優(yōu)點(diǎn)。風(fēng)機(jī)盤管直接設(shè)置在房間內(nèi)對(duì)室內(nèi)的回風(fēng)進(jìn)行處理,新風(fēng)則由新風(fēng)機(jī)組集中處理后通過(guò)新風(fēng)管道送入室內(nèi)。6.1.1 空氣處理過(guò)程及計(jì)算 風(fēng)機(jī)盤管其夏季處理過(guò)程焓濕圖如下:圖4.2夏季風(fēng)機(jī)盤管處理過(guò)程焓濕圖新風(fēng)處理到室內(nèi)等焓點(diǎn)與機(jī)器露點(diǎn)的焦點(diǎn),其不承擔(dān)室內(nèi)冷負(fù)荷,承擔(dān)一部分濕負(fù)荷。熱濕比: 總送風(fēng)量: 新風(fēng)量: fcu的風(fēng)量: 對(duì)于m點(diǎn)焓值的確定: 由于 根據(jù)以上計(jì)算過(guò)程,可初步選取空氣處理設(shè)備。 6.2 半集中式系統(tǒng)的設(shè)備選型6.2.1 風(fēng)機(jī)盤管選型現(xiàn)在以第二層2002客房為例,進(jìn)行選型。房間的冷負(fù)荷(不含新風(fēng)負(fù)荷時(shí))為q=0.3512kw,濕負(fù)荷m=0.14kg/h,室內(nèi)空氣
30、計(jì)算溫度=25,相對(duì)濕度55,室外干球溫度=32.1,相對(duì)濕度為48.76,該房間室內(nèi)人員2人,總新風(fēng)量為1203/h。其焓濕圖如下圖4.3風(fēng)機(jī)盤管處理焓濕圖查焓濕圖可得: 風(fēng)機(jī)盤管的風(fēng)量: g=644m/h =644-120=524 m/h 新風(fēng)比= =23所以風(fēng)機(jī)盤管冷量:=524*(56-30.3)*1000/3600=3740.78w=3.7kw根據(jù)相同的方法可以算出其他房間的室內(nèi)空氣處理過(guò)程。根據(jù)風(fēng)機(jī)盤管的冷量和風(fēng)量可對(duì)風(fēng)機(jī)盤管進(jìn)行選型??头康娘L(fēng)機(jī)盤管型號(hào)為:fp-51wa,其他房間的風(fēng)機(jī)盤管型號(hào)見下表:附表7:各房間風(fēng)機(jī)盤管型號(hào)匯總房間型號(hào)轉(zhuǎn)速hfcf風(fēng)量 m/h冷量 kw水量 k
31、g/h水壓降 kpa備注1號(hào)樓二層客房fp-51wa中速3832.543521111個(gè)客房fp-51wa中速3832.543521111個(gè)客房fp-51wa中速3832.543521111個(gè)客房fp-51wa中速3832.543521111個(gè)值班室fp-51wa中速3832.543521111個(gè)物品保管室fp-51wa中速3832.543521111個(gè)管理辦公室fp-51wa中速3832.543521111個(gè)三-十三層客房fp-51wa中速3832.543521111個(gè)客房fp-51wa中速3832.543521111個(gè)客房fp-51wa中速3832.543521111個(gè)客房fp-51wa中速
32、3832.543521111個(gè)客房fp-51wa中速3832.543521111個(gè)客房fp-51wa中速3832.543521111個(gè)客房fp-51wa中速3832.543521111個(gè)客房fp-51wa中速3832.543521111個(gè)客房fp-51wa中速3832.543521111個(gè)客房fp-51wa中速3832.543521111個(gè)2、3號(hào)樓一層商鋪fp-102wa中速7655.4901084132個(gè)商鋪fp-102wa中速7655.4901084132個(gè)商鋪fp-170wa中速12788.5371750132個(gè)商鋪fp-170wa中速12788.5371750132個(gè)商鋪fp-170
33、wa中速12788.5371750132個(gè)二層小餐廳fp-102wa中速7655.4901084131個(gè)小餐廳fp-102wa中速7655.4901084131個(gè)小餐廳fp-102wa中速7655.4901084131個(gè)小餐廳fp-102wa中速7655.4901084131個(gè)小餐廳fp-102wa中速7655.4901084131個(gè)餐廳fp-170wa中速12788.5371750136個(gè)商鋪fp-170wa中速12788.5371750131個(gè)商鋪fp-170wa中速12788.5371750131個(gè)商鋪fp-170wa中速12788.5371750131個(gè)商鋪fp-170wa中速1278
34、8.5371750131個(gè)商鋪fp-170wa中速12788.5371750131個(gè)三層會(huì)議室fp-204wa中速1530 10.0622111139個(gè)商務(wù)辦公fp-170wa中速12788.5371750131個(gè)商務(wù)辦公fp-170wa中速12788.5371750131個(gè)四層商務(wù)辦公fp-170wa中速12788.5371750131個(gè)商務(wù)辦公fp-170wa中速12788.5371750131個(gè)辦公室fp-85wa中速6383.213876121個(gè)辦公室fp-68wa中速5103.427693131個(gè)辦公室fp-68wa中速5103.427693131個(gè)辦公室fp-68wa中速5103.
35、427693131個(gè)辦公室fp-51wa中速3832.543521111個(gè)辦公室fp-51wa中速3832.543521111個(gè)會(huì)議室fp-170wa中速12788.5371750132個(gè)五層雅間fp-170wa中速12788.5371750131個(gè)雅間fp-170wa中速12788.5371750131個(gè)雅間fp-170wa中速12788.5371750131個(gè)雅間fp-170wa中速12788.5371750131個(gè)雅間fp-170wa中速12788.5371750131個(gè)酒吧fp-170wa中速12788.5371750132個(gè)茶室fp-204wa中速1530 10.0622111133
36、個(gè)商務(wù)辦公fp-170wa中速12788.5371750131個(gè)商務(wù)辦公fp-170wa中速12788.5371750131個(gè)六層商務(wù)辦公fp-170wa中速12788.5371750131個(gè)商務(wù)辦公fp-170wa中速12788.5371750131個(gè)圖書室fp-85wa中速6383.213876122個(gè)檔案室fp-170wa中速12788.5371750132個(gè)辦公室fp-85wa中速6383.213876121個(gè)辦公室fp-85wa中速6383.213876121個(gè)辦公室fp-85wa中速6383.213876121個(gè)辦公室fp-85wa中速6383.213876121個(gè)辦公室fp-85
37、wa中速6383.213876121個(gè)七層辦公室fp-51wa中速3832.543521111個(gè)辦公室fp-51wa中速3832.543521111個(gè)辦公室fp-51wa中速3832.543521111個(gè)辦公室fp-51wa中速3832.543521111個(gè)辦公室fp-51wa中速3832.543521111個(gè)辦公室fp-51wa中速3832.543521111個(gè)辦公室fp-51wa中速3832.543521111個(gè)辦公室fp-51wa中速3832.543521111個(gè)辦公室fp-102wa中速7655.4901084131個(gè)6.2.2 新風(fēng)機(jī)選型由于本工程為13層建筑,總新風(fēng)量大,且沒有專門
38、設(shè)計(jì)新風(fēng)機(jī)房,所以在每層采用吊頂系列空氣處理機(jī)組。 根據(jù)前面所計(jì)算出的層樓新風(fēng)冷負(fù)荷及風(fēng)量(參見冷負(fù)荷計(jì)算書),可以對(duì)新風(fēng)機(jī)組進(jìn)行選型。表5.1 新風(fēng)機(jī)組型號(hào)匯總機(jī)組規(guī)格風(fēng)量冷量 kw水流量 l/s臺(tái)數(shù)1號(hào)樓2層gx615(1)150025.71.2413-13層gx615(1)150025.71.2411機(jī)組規(guī)格風(fēng)量冷量 kw水流量 l/s臺(tái)數(shù)2號(hào)樓1層gx650(1)500089.54.3212層gx630(1)300050.72.441gx680(1)80001386.6513層gx680(1)80001386.651gx615(1)150025.71.24114層gx630(1)300
39、050.72.441gx615(1)150025.71.24115層gx680(1)80001386.651gx615(1)150025.71.24116層gx630(1)300050.72.441gx615(1)150025.71.24117層gx615(1)150025.71.2411第七章 氣流組織計(jì)算7.1 側(cè)送氣流組織側(cè)送風(fēng)是空調(diào)房間中最常用的一種氣流組織方式。側(cè)送風(fēng)有單側(cè)上送下回,單側(cè)上送走廊回風(fēng)、單側(cè)上送上回、雙側(cè)上送下回等多種形式??偠灾?,側(cè)送的主要特點(diǎn)是溫度場(chǎng)、速度場(chǎng)均勻,混合層高度是0.30.5m。7.1.2側(cè)送風(fēng)口選擇計(jì)算現(xiàn)在對(duì)2001客房進(jìn)行通風(fēng)以及氣流組織的設(shè)計(jì),客
40、房的高為3.6m,長(zhǎng)為7.4m,寬為3.9m,總冷負(fù)荷為2466.6w。室內(nèi)空調(diào)系統(tǒng)采用的是風(fēng)機(jī)盤管加新風(fēng)系統(tǒng),其安裝的風(fēng)機(jī)盤管為fp-51wa型,風(fēng)量530 m3/h,即425l/s;新風(fēng)量為100m3/h。新風(fēng)作為輔助送風(fēng),為簡(jiǎn)化計(jì)算,可忽略新風(fēng)對(duì)氣流的影響,因此只需對(duì)風(fēng)機(jī)盤管送風(fēng)的氣流組織進(jìn)行計(jì)算。1) 選定送風(fēng)口形式,確定風(fēng)口布置 送風(fēng)口采用散流器送風(fēng)口,其紊流系數(shù)為=0.16,設(shè)風(fēng)口離墻面0.5米,射流的射程為7.4-0.5-0.5=6.4 m(0.5 m為射流末端寬度)。2)選取送風(fēng)溫差t根據(jù)規(guī)范要求,選定t=10。3)定送風(fēng)口的出流速度v0 m/s (7.1)式中:fn垂直于單股
41、射流的空間斷面面積,m2,見(7.2)d0送風(fēng)口直徑或當(dāng)量直徑,m。 (7.2)先假定v0=3 m/s,由公式(7.2)算出射流自由度0為12.831,代入公式(7.1)=0.36 12.831=4.62m/s。所取v0=3 m/s4.4,滿足要求。7)校核房間高度公式h=h+w+0.07x+0.3 m ,房間高度=h為滿足要求; (7.7)h=h+w+0.07x+0.3=2+0.23+0.074.87+0.3 =2.553.6m 可見,房間高度負(fù)荷要求。同理,其余房間風(fēng)機(jī)盤管的送風(fēng)口大小都可依據(jù)此法計(jì)算出。第八章. 空調(diào)冷熱源設(shè)備選型8.1 冷源的確定冷水機(jī)組是空調(diào)系統(tǒng)的心臟,正確地選擇冷水
溫馨提示
- 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 職場(chǎng)中自我管理的藝術(shù)計(jì)劃
- 膝痹中醫(yī)護(hù)理措施
- 班級(jí)資源共享平臺(tái)的搭建計(jì)劃
- 《貴州新宜礦業(yè)(集團(tuán))有限公司普安縣樓下鎮(zhèn)郭家地煤礦(變更)礦產(chǎn)資源綠色開發(fā)利用方案(三合一)》評(píng)審意見
- 管路護(hù)理新進(jìn)展
- 紅斑狼瘡護(hù)理診斷及護(hù)理措施
- 統(tǒng)編版小學(xué)語(yǔ)文二年級(jí)下冊(cè)第22課《小毛蟲》精美課件
- 2025年鹽城如何考貨運(yùn)從業(yè)資格證
- 2025年張掖貨運(yùn)資格證考試有哪些項(xiàng)目
- 2025年嘉峪關(guān)貨運(yùn)上崗證考試題庫(kù)1387題
- 《苗圃生產(chǎn)與管理》教案-第二章 園林苗木的種實(shí)生產(chǎn)
- 2025年西安鐵路職業(yè)技術(shù)學(xué)院高職單招高職單招英語(yǔ)2016-2024歷年頻考點(diǎn)試題含答案解析
- 化工原理完整(天大版)課件
- 2025年陜西延長(zhǎng)石油有限責(zé)任公司招聘筆試參考題庫(kù)含答案解析
- 《淞滬會(huì)戰(zhàn)》課件
- Excel辦公技巧培訓(xùn)
- 《信息論緒論》課件
- 新時(shí)代大學(xué)生勞動(dòng)教育 課件 第5章 勞動(dòng)素養(yǎng)及其養(yǎng)成
- 2024年度英語(yǔ)課件容貌焦慮
- 初一家長(zhǎng)會(huì)課件96108
- 《企業(yè)文化概述》課件
評(píng)論
0/150
提交評(píng)論