擠塑板外墻保溫施工方案_第1頁(yè)
擠塑板外墻保溫施工方案_第2頁(yè)
擠塑板外墻保溫施工方案_第3頁(yè)
擠塑板外墻保溫施工方案_第4頁(yè)
擠塑板外墻保溫施工方案_第5頁(yè)
已閱讀5頁(yè),還剩12頁(yè)未讀, 繼續(xù)免費(fèi)閱讀

下載本文檔

版權(quán)說(shuō)明:本文檔由用戶(hù)提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)

文檔簡(jiǎn)介

1、 學(xué)府公館14#樓擠塑聚苯板外墻保溫施工方案編制: 審核: 周口振興建筑工程有限公司2016年5月3日目錄1編制依據(jù) ········································&

2、#183;·················································&

3、#183;··············32工程概況 ··································

4、··················································

5、······················33材料技術(shù)指 標(biāo) ··························&#

6、183;·················································&#

7、183;···· ·····34施工準(zhǔn)備 ·······································

8、··················································

9、·················55施工工藝 ································

10、;··················································

11、;························56 質(zhì)量檢驗(yàn) ························

12、83;·················································

13、83;······························117 其他注意事項(xiàng)··················

14、;··················································

15、;·······························138 質(zhì)量保真措施 ·················

16、··················································

17、·······························139 技術(shù)管理 ·················

18、83;·················································

19、83;······································1410 成品保護(hù) ··········

20、;··················································

21、;···············································1411 現(xiàn)場(chǎng)施工安全措施

22、3;·················································

23、3;···········································1512 現(xiàn)場(chǎng)安全維護(hù)措施····

24、83;·················································

25、83;·······································15一、編制依據(jù)GB/T10801.2-2002絕熱用擠塑聚苯乙烯泡沫塑料(XPS)JGJ144-2008外墻外保溫工程技術(shù)規(guī)

26、程GB502032011砌體工程施工質(zhì)量驗(yàn)收規(guī)范GB502042011混凝土結(jié)構(gòu)工程施工質(zhì)量驗(yàn)收規(guī)范GB503002013建筑工程施工質(zhì)量驗(yàn)收統(tǒng)一標(biāo)準(zhǔn)GB502102011建筑裝飾裝修工程質(zhì)量驗(yàn)收規(guī)范12YJ3-7擠塑泡沫板外墻保溫構(gòu)造二、工程概況學(xué)府公館14#樓工程位于羲皇大道東側(cè),趙玲藝術(shù)學(xué)校北側(cè), 1#樓建筑面積4894,2#樓建筑面積44583#樓建筑面積4458。8#樓建筑面積11873。商業(yè)建筑面積3383.工程總建筑面積29070m2。本工程高層樓體外墻采用擠塑聚苯板為主要保溫隔熱材料,以粘、釘結(jié)合方式與墻身固定,抗裂砂漿復(fù)合耐堿玻纖網(wǎng)格布為保護(hù)增強(qiáng)層,涂料飾面的外墻保溫系統(tǒng)。三

27、、材料技術(shù)指標(biāo)表一 擠塑板性能指標(biāo)符合質(zhì)量驗(yàn)收標(biāo)準(zhǔn)(GB/T10801.2-2002)難燃1級(jí)擠塑板,表觀密度為25/m3密度32/m3,尺寸(1200×600×40)擠塑式保溫板。項(xiàng) 目單 位指 標(biāo)表觀密度/m³25-32導(dǎo)熱系數(shù)W/m·k0.030壓縮強(qiáng)度kPa150250陳化時(shí)間自然條件天42蒸氣(600C)天5吸水率(浸水96小時(shí))%1.5難燃性1表二 砂漿膠粘劑技術(shù)指標(biāo)聚合物粘結(jié)膠漿是高分子聚合物材料,符合下列數(shù)據(jù)項(xiàng) 目單位指 標(biāo)拉伸粘結(jié)強(qiáng)度(與水泥砂漿)常溫常態(tài) 14天MPa0.60耐水(浸水48小時(shí) 放置24小時(shí))0.40耐凍融(凍融循環(huán)2

28、5次)0.50拉伸粘結(jié)強(qiáng)度(與擠塑板)常溫常態(tài) 14天MPa0.2且擠塑板破壞耐水(浸水48小時(shí) 放置24小時(shí))0.2且擠塑板破壞耐凍融(凍融循環(huán)25次)0.2且擠塑板破壞可操作時(shí)間小時(shí)2抗壓強(qiáng)度/抗折強(qiáng)度3.0表三 抗裂砂漿技術(shù)指標(biāo)外墻外保溫抗裂砂漿是高分子聚合物材料,符合下列數(shù)據(jù)為準(zhǔn)。項(xiàng) 目單位指 標(biāo)可操作時(shí)間小時(shí)1.5拉伸粘結(jié)強(qiáng)度(常溫28天)MPa 0.7抗壓強(qiáng)度MPa8柔韌性(抗壓強(qiáng)度/抗折強(qiáng)度) 3.0表四 耐堿型玻璃纖維網(wǎng)格布技術(shù)要求涂塑耐堿玻璃纖維網(wǎng)格布符合(容重160 g/)采用抗堿性高級(jí)玻璃纖維編織而成。項(xiàng) 目單位性能指標(biāo)(標(biāo)準(zhǔn)網(wǎng)布)網(wǎng)孔中心距mm4.55.5單位面積質(zhì)量g

29、/160耐堿斷裂強(qiáng)力保留率(經(jīng)緯向)%50斷裂強(qiáng)力(經(jīng)、緯向)N/50mm750斷裂應(yīng)變(經(jīng)、緯向)%5.0表五 機(jī)械錨固件的主要技術(shù)指標(biāo)機(jī)械錨固件:錨栓由外層套管和內(nèi)部螺栓兩部分組成。塑料膨脹釘(圓盤(pán)直徑5cm)加自攻螺絲釘10、長(zhǎng)102mm置入墻體深度不小于50mm。序號(hào)試驗(yàn)項(xiàng)目技術(shù)指標(biāo)1單個(gè)錨栓抗拉承載力標(biāo)準(zhǔn)值(kN)0.302單個(gè)錨栓對(duì)系統(tǒng)傳熱增加值,W/K0.004四、施工準(zhǔn)備4、1 作業(yè)條件4.1.1結(jié)構(gòu)已驗(yàn)收完,墻面彈出+50線。4.1.2外墻面的預(yù)埋件、設(shè)備穿墻管道等提前完畢,并留出外保溫厚度,結(jié)構(gòu)施工時(shí)的預(yù)留洞提前堵塞嚴(yán)密。4.1.3操作地點(diǎn)環(huán)境溫度不低于5度。雨天,風(fēng)力大于

30、四級(jí)天氣,雨雪天不施工。4、2主要機(jī)具切割器、沖擊鉆、手提攪拌器、放線工具,手推車(chē),水桶、剪子、壁紙刀、螺絲刀、掃帚、鐵鍬、鋼絲刷、水灰斗、開(kāi)刀、撬棍、鋼尺、橡皮錘、木楔、抹子、壓子、陰陽(yáng)角抿子、托線板、皮尺、2米靠尺、水平尺,鋸齒抹子。五、施工工藝5.1工藝流程(圖)材料及工具準(zhǔn)備基層清理彈線、掛線配粘結(jié)砂漿在擠塑板上涂刷界面劑粘貼擠塑板安裝錨固件抹底層砂漿鋪設(shè)玻纖網(wǎng)抹面層砂漿刮柔性膩?zhàn)铀椥酝苛蠙z驗(yàn)驗(yàn)收5.2 施工要求結(jié)構(gòu)基層墻體處理:表面平整度應(yīng)達(dá)到建筑工程質(zhì)量檢驗(yàn)評(píng)定標(biāo)準(zhǔn)(GBJ301-88)中的相關(guān)要求。掃凈墻面,用水清洗;并檢驗(yàn)墻面平整度和垂直度。用2m靠尺檢查,最大偏差不大于5m

31、m,超差部分應(yīng)由土建方剔鑿或用聚合物水泥砂漿修補(bǔ)平整。5.3.放線、打點(diǎn)5.3.1彈控制線根據(jù)建筑立面設(shè)計(jì)和外墻外保溫技術(shù)要求,在墻面彈出門(mén)窗水平、垂直控制線等。5.3.2掛基準(zhǔn)線在外墻大角(陰陽(yáng)角)及其它必要處掛垂直基準(zhǔn)線,每個(gè)樓層墻面適當(dāng)位置掛水平線,以控制擠塑板的垂直度和平整度。5.4材料配制粘結(jié)砂漿根據(jù)生產(chǎn)廠使用說(shuō)明書(shū)提供的配合比配置(粘結(jié)砂漿:水=4-4.5:1),專(zhuān)人負(fù)責(zé),嚴(yán)格計(jì)量,確保攪拌均勻。攪拌好的粘結(jié)劑在靜停10min后還需要二次攪拌才能使用。配置好的粘結(jié)料注意防曬避風(fēng),以免水分蒸發(fā)過(guò)快。一次配置量應(yīng)在2小時(shí)內(nèi)用完。 面層砂漿按照上述方法進(jìn)行配置。5.5擠塑板的粘貼施工方法

32、5.5.1條點(diǎn)法擠塑板四周邊涂抹寬約60mm的粘結(jié)砂漿,厚10mm;中間布設(shè)8個(gè)粘結(jié)點(diǎn),直徑150mm,厚度10mm,矩形布置,保證粘結(jié)面積不小于40%。側(cè)面留50mm寬的一個(gè)排氣口。5.5.2擠塑板抹完粘結(jié)砂漿后,應(yīng)立即將板平貼在基層墻體上滑動(dòng)就位。粘貼時(shí)應(yīng)輕揉、均勻擠壓砂漿層;為了保證板面的平整度,應(yīng)隨時(shí)用一根長(zhǎng)度不小于2.0m的靠尺進(jìn)行壓平操作。5.5.3 擠塑板應(yīng)橫向鋪貼,每排板應(yīng)錯(cuò)縫1/2板長(zhǎng)。5.5.4板粘牢后,隨時(shí)用專(zhuān)用的搓抹子將板邊的不平之處搓平,盡量減少板與板之間的高差接縫,當(dāng)板縫間隙大于1.5cm時(shí),應(yīng)用擠塑板條填實(shí)后磨平。5.5.5 擠塑板表面不平整處至少靜置24小時(shí)后,

33、才能用 砂紙磨平,打磨板面的動(dòng)作應(yīng)是輕柔的圓周運(yùn)動(dòng)。打磨時(shí)散落的碎屑應(yīng)隨時(shí)清理干凈。5.5.6粘貼擠塑板時(shí)應(yīng)注意以下事項(xiàng): 操作應(yīng)迅速,在擠塑板安裝就位之前,粘結(jié)砂漿不得有結(jié)皮。擠塑板的接縫應(yīng)緊密平齊。不得在擠塑板側(cè)面涂抹砂漿,或擠放粘結(jié)砂漿,以免引起開(kāi)裂。對(duì)于管道處粘貼時(shí)應(yīng)根據(jù)現(xiàn)場(chǎng)形狀把擠塑板仔細(xì)裁剪出要求形狀。5.6安裝固定件在貼好并已靜置了24小時(shí)的擠塑板上用沖擊鉆鉆孔,錨栓進(jìn)入墻體50mm,錨栓數(shù)量為:每平米7個(gè)。如下圖:門(mén)窗洞口錨釘及加固方式如下圖:5.7鋪設(shè)耐堿玻纖網(wǎng)格布門(mén)窗洞口四角處沿45度方向補(bǔ)貼一塊標(biāo)準(zhǔn)耐堿玻纖網(wǎng)格布,尺寸為200×300,以防開(kāi)裂。耐堿網(wǎng)格布翻包:

34、門(mén)窗洞口、變形縫兩側(cè)等處的擠塑聚苯板預(yù)粘貼耐堿網(wǎng)格布,總寬度200mm+板厚,翻包寬度為100mm,具體做法如下:耐堿網(wǎng)格布裁剪長(zhǎng)度為200mm+板厚,首先在翻包部位抹長(zhǎng)度為100mm、厚度為2mm的粘貼砂漿,然后壓入100mm長(zhǎng)的耐堿網(wǎng)格布,余下的甩出備用。貼好的擠塑板靜置24小時(shí)后,自上而下鋪設(shè)耐堿玻纖網(wǎng)格布5.7.1耐堿玻纖網(wǎng)格布的鋪設(shè)應(yīng)自上而下的進(jìn)行,鋪設(shè)耐堿玻纖網(wǎng)格布時(shí)應(yīng)注意以下事項(xiàng):5.7.1.1不得在雨中鋪設(shè)耐堿玻纖網(wǎng)格布,耐堿玻纖網(wǎng)格布剪裁應(yīng)盡量沿經(jīng)緯線方向進(jìn)行。5.7.1.2耐堿玻纖網(wǎng)格布間應(yīng)相互搭接橫向100mm,縱向100mm。5.7.1.3在陰角部位,鋪耐堿玻纖網(wǎng)格布之

35、前應(yīng)補(bǔ)貼一塊耐堿玻纖網(wǎng)格布寬度不小于200+板厚,以防開(kāi)裂。5.7.1.4拐角部位,耐堿玻纖網(wǎng)格布應(yīng)是連續(xù)的,并從每邊雙向繞角后包墻的寬度不小于200mm+板厚。 5.7.1.5陽(yáng)臺(tái)欄板的保溫板及裝飾線部位,耐堿玻纖網(wǎng)格布的搭接應(yīng)不小于100。5.7.1.6涂抹抹面砂漿前,應(yīng)先檢查擠塑板是否干燥,錨固是否結(jié)實(shí),并去除板面的有害物質(zhì)、雜質(zhì)或表面變質(zhì)部分。5.7.1.7抹底層抗裂砂漿同時(shí)壓入耐堿玻纖網(wǎng)格布,厚度約為2。5.7.1.8抹面層抗裂砂漿做法:用抹子在鋪設(shè)好耐堿玻纖網(wǎng)格布的擠塑板表面均勻涂抹一層抹面砂漿,厚度約為1 mm,以微露網(wǎng)格布為宜;抗裂砂漿總厚度為3-5mm。5.7.1.9耐堿玻纖

36、網(wǎng)格布抹完抹面砂漿后,至少靜置養(yǎng)護(hù)24小時(shí),方可進(jìn)行下一道工序的施工。在潮濕的天氣,應(yīng)適當(dāng)延長(zhǎng)養(yǎng)護(hù)時(shí)間。5.7.2 特殊部位的處理5.7.2.1可能遭受沖擊力的部位應(yīng)作特殊處理。5.7.2.2特殊部位的處理A、門(mén)窗洞口處,粘板前應(yīng)先鋪設(shè)一道200寬的翻包網(wǎng)格布;B、施工勒腳時(shí),為防止擠塑板下滑,可在每塊擠塑板下放置兩個(gè)支撐塊。5.7.2.3防火隔離帶 根據(jù)公安部、住房和城鄉(xiāng)建設(shè)部于2009年9月28 日印發(fā)的公通字200946號(hào)文,即民用建筑外保溫系統(tǒng)及外墻裝飾防火暫行規(guī)定高度大于等于24m小于60m的建筑,其保溫材料的燃燒性能不應(yīng)低于B2級(jí)?,F(xiàn)采用B1級(jí)擠塑板,每?jī)蓪樱ㄅ紨?shù)層)應(yīng)沿樓板位置連

37、續(xù)通長(zhǎng)設(shè)置水平防火隔離帶,寬度300mm。(1)本方案防火隔離帶是采用A級(jí)防火巖棉板。 (2)基本構(gòu)造示意圖如下:六、 質(zhì)量檢驗(yàn)6.1主控項(xiàng)目6.1.1保溫系統(tǒng)所有的材料必須符合設(shè)計(jì)要求和本規(guī)程的有關(guān)規(guī)定。檢驗(yàn)方法:檢查產(chǎn)品質(zhì)量合格證明文件、型式檢驗(yàn)機(jī)出廠檢驗(yàn)報(bào)告和現(xiàn)場(chǎng)抽樣試驗(yàn)報(bào)告。6.1.2 XPS板的厚度及保溫系統(tǒng)的構(gòu)造和細(xì)部做法應(yīng)符合建筑節(jié)能設(shè)計(jì)要求。檢驗(yàn)方法:鋼針插入和尺量檢查,觀察檢查。6.1.3 XPS板與墻體必須粘結(jié)牢固,無(wú)松動(dòng)和虛粘現(xiàn)象。檢驗(yàn)方法:觀察檢查和檢查基層與膠粘劑的拉伸強(qiáng)度檢驗(yàn)報(bào)告。6.1.4 安裝錨栓的墻面,錨栓數(shù)量、位置、錨固深度和防銹處理應(yīng)符合設(shè)計(jì)要求。檢驗(yàn)方法

38、:卸下錨栓,觀察檢查和實(shí)測(cè)錨固深度。6.1.5 抹面砂漿與XPS板必須粘結(jié)牢固,無(wú)脫層和空鼓現(xiàn)象;面層無(wú)爆灰和裂縫等缺陷。檢驗(yàn)方法:用小錘輕擊和觀察檢查。6.2一般項(xiàng)目6.2.1 XPS 板安裝應(yīng)上下錯(cuò)縫,各XPS板間應(yīng)擠緊拼嚴(yán),拼縫平整,碰頭縫不得抹粘接砂漿。檢驗(yàn)方法:觀察和手摸檢查。6.2.2 XPS 板安裝允許偏差和檢驗(yàn)方法應(yīng)符合本規(guī)程表1的規(guī)定6.2.3耐堿網(wǎng)布應(yīng)鋪壓嚴(yán)實(shí),不得有空鼓、褶皺、翹曲、外露等現(xiàn)象,搭接寬度不小于100mm,加強(qiáng)部位的耐堿網(wǎng)布做法應(yīng)符合設(shè)計(jì)要求。檢驗(yàn)方法:觀察檢查。6.2.4抹面層的允許偏差和檢驗(yàn)方法應(yīng)符合表2的規(guī)定。表1 擠塑板安裝允許偏差及檢查方法項(xiàng)次項(xiàng)目

39、允許偏差(mm)檢查方法1表面平整4用2m靠尺和塞尺檢查2立面垂直4用2m垂直檢測(cè)尺檢查3陽(yáng)角方正3用200mm方尺和塞尺檢查4接縫高差1.5用直尺和塞尺檢查5接縫寬度2用尺量檢查表2 抹面層的允許偏差和檢驗(yàn)方法項(xiàng)次項(xiàng)目允許偏差(mm)檢查方法1表面平整4用2m靠尺和塞尺檢查2立面垂直4用2m垂直檢測(cè)尺檢查3陽(yáng)角方正4用200mm方尺和塞尺檢查4分格縫(裝飾線)直線度4用5m線,不足5m拉通線,用鋼直尺檢查七、 其它注意事項(xiàng) 7.1各種材料應(yīng)分類(lèi)存放并掛牌標(biāo)明材料名稱(chēng),不得用錯(cuò)。 7.2暑天施工時(shí),若砂漿凝結(jié)速度快,應(yīng)適當(dāng)安排不同作業(yè)面的作業(yè)時(shí)間,盡量避開(kāi)日光暴曬時(shí)段。 7.3 對(duì)抹完抗裂砂漿的保溫墻體,不得隨意開(kāi)鑿孔洞,如果實(shí)需要,應(yīng)在抗裂砂漿達(dá)到設(shè)計(jì)強(qiáng)度后方可進(jìn)行,安裝物件后其周?chē)鷳?yīng)恢復(fù)原狀。 7.4 應(yīng)防止重物撞擊墻面。7.5 應(yīng)嚴(yán)格遵守有關(guān)安全操作規(guī)程,合理安排工序,嚴(yán)禁顛倒工序作業(yè)。八、質(zhì)量保證措施1.嚴(yán)把進(jìn)場(chǎng)材料質(zhì)量關(guān),不合格的材料絕不在工程中使用。2.建立健全質(zhì)量保證體系,成立以項(xiàng)目經(jīng)理為首的質(zhì)量檢查小組,定期地進(jìn)行綜合或單項(xiàng)質(zhì)量檢查,督促操作人員嚴(yán)把質(zhì)量關(guān)。3.每道工序施工必須作好技術(shù)交底工作,將技術(shù)要求、操作要領(lǐng)、質(zhì)量要求貫徹到每位操作人員,使大家做到心中有數(shù),正確施工。4

溫馨提示

  • 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶(hù)所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶(hù)上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶(hù)上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶(hù)因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。

評(píng)論

0/150

提交評(píng)論