1、Compact Non-contact Door SwitchD40ZWide range of applications at the highest safety levelV i s i b l e safetyU l t imate safetyl evelapplications»Versatile»Compliant with Safety PLe/Category 4 (ISO 13849-1) The compact non-contact feature allows easier installation for a wide range of envi

2、ronments.The D40Z can be used in work environments under any risk level.Its combination with safety controllers allows for a wide range of applications.Actual SizeD40ZMounts on Either SideOperating distance(ONOFF) :15 mm max.Safety CategoriesDifferent types of machines will have different levels of

3、associated risk. As an index for determining the function to secure safety (safety function) based on the risk evaluation, the ISO 13849-1 which stipulates safety-related parts of control systems, categorizes the capability to maintain safety functions in the event of control system failures as cate

4、gory B to 4.Performance Level (PL)An index of the safety control system performance level shared by awhoimplements risk assessment and awho designs a machine is calledPerformance Level (hereinafter abbreviated as "PL") and has 5 levels of evaluation from "a" to "e".Fors

5、 on safety category and PL, refer to page 5.1D40Z FeaturesVisible safetyChecking at the production siteThe switch's LED indication patterns make identification of abnormal condition possible at the production sites.Note: For more information, refer to page 10.Centralized monitoringBipolar NPN/PN

6、P allows for easy connection with any PLC. The error location can be easily identified. Using a branch relay for a different pole is not required.D40ZPLCYellow LED ON: Doord (normal)Red LED ON: Door OpenYellow LED Blinking : When connected in series;Other D40Zs are turned OFF etc.Red LED Blinking: E

7、rror occurred2Auxiliary outputG9SX-NSHigh level of safety for a wide range of applicationsISO 13849-1 (PLe/Safety Category 4) achieved with Non-contact Door Switches Self-diagnostic FunctionOMRONs unique electromagnetic induction system for safety was achieved by implementing a detection function fo

8、r external wiring errors in the Switch. Redundnternal circuitsThe thorough pursuit of safety is evident in mutual checking by double CPUs.Series connections Up 30 Switches can be connected to one Controller while maintaining PLe/safety category 4.The D40Z can be connected to G9SP or G9SX-NS Safety C

9、ontrollers. Select the best mfor your application.Previous configurationConfiguration with the D40ZMany ControllersOne ControllerParallel connectionsSeries connectionNote 1 : The G9SP supports 2 channels of 15 units each. For more information, refer to Applicable level and the number of connections

10、according to controller combination on page 5.Note 2 : Refer to page 16 fors on safety categories (ISO 13849-1).How PLe/safety category 4 was achieved with series connections Safety software monitoring and diagnosis to detect failures (not possible with series connections of mechanical switches)Seri

11、es connections of mechanical switchesSeries connections of the D40ZD40ZD40ZD40ZActivateswarning display.From ControllerTo ControllerFrom ControllerOutput OFF To Controller Faults may not be detected,Monitoring and diagnosis bye.g., for short-circuits insafety software enablesswitch I/O wiring.detect

12、ing errors, such asshort-circuits in D40Z I/O wiring.Electromagnetic induction method Enables stable detection No adhesion of iron particlesWith these electronic switches, stable detection is possiblePermanent magnets are not used, so iron is not attracted, even when the doors slowly.making maintena

13、nce easier.Up to 30 Switchescan be connected.For an easier and safer work environment in all industries.The application of the D40Z willcontinue to increase in all environments.Automotive manufacturing (multi-axis robot)Position detection of a robot (hazard)Detecting the position of a multi-axis rob

14、ot is difficult using a limit switch. Additionally, it is easy to disable the function.Safety detection locationThe non-contact door switch enables ease in detecting the robot position which prevents the operator from easily disabling the function.The maintenance work is safer than ever as the switc

15、h conforms to ISO 13849-1 (PLe/safety category 4).Wide detection areaKey factorSafety detection locationISO 13849-1 (PLe/Safety Category 4)Manufacturing processThere are too many doors, and it takes too long to identify the location of a failure when it occurs.Auxiliary output is provided for each s

16、witch. As each switch can be monitored, it is possible to pinpoint the location of the failure.Up to 30 units can be connectedPLCOther Application Examples3Auxiliary outputsProblemSolutionProblemSolutionD40ZEquipment for long production linesKey factorPNP/NPNUp to 30 units connectableFPDG9SX-NSD40ZD

17、40Z application examplesThe D40Z solves problems at the production sites of various industries that require safety (FPD, automotive parts, food, packaging, multi-axis robot, etc).The D40Z supports a wide range of risk levels, contributing to a safer environment atproduction sites for various industr

18、ies' applications.FoodMaterial processingThe machine's small size limits the space available to install a switch.The D40Z's compact size fits into a narrow space (Switch: 48x48x25 mm, Actuator: 48x48x17 mm). The D40Z can be used at an ambient operating temperature of up to 65°C.Comp

19、act sizeKey factorImprovement on ambient operating temperatureAutomotive partsManufacturing process for secondary batteriesAlthough safety is ensured with a contact door switch, particles are generated which affect product quality.With the non-contact door switch D40Z, no particles will be generated

20、 through friction.Other Application Examples4ProblemSolutionProblemSolutionD40ZCleanroomsKeyNo particles generationfactorD40ZSelectable controllersA wide range of choices for the versatile applicationsA combination of non-contact door switches and safety controllers can be selected according to the

21、application or the required risk level.Mounting compatibility with the D40A allows for standardization of machine design.Non-contact Door SwitchApplicable level and the number of connections according to controller combinationPL/Safety CategoryPLe/4 D40Z PLd/3D40A* G9SP-N10S supports 15 x 1 channel.

22、5Safety ControllerNon-contact Door Switch ControllerG9SPG9SX-NS Combine function blocks for flexible program Easy expansion of output points with an expansion unit Extensive system configurations Improved maintainability with LED display Decreased work hours by convenient configurator No special pro

23、gramrequired Function blocksG9SP Series CatalogCatalog No.: J181D40A/G9SX-NS CatalogCatalog No.: C140CombinationSafety CategoryPLNumber of connectable(um value)D40Z SeriesG9SP+D40A3PLd15 x 2channels*G9SX-NS+D40A3PLd30G9SX-NSA+D40A3PLd30CombinationSafety CategoryPL(um value)Number of connectable D40Z

24、 SeriesG9SP+D40Z4PLe15 x 2channels*G9SX-NS+D40Z4PLe30G9SX-NSA+D40Z4PLe30Supports ISO 13849-1 (PLe/Safety Category 4). Can be used on higher risk level applications by connecting to Safety Controllers. Supports a wide range of applications in combination withNon-contact Door Switch D40ZSafety Control

25、ler G9S Controller G9SX-NS.on-contact Door Switch Up to 30 units can be connected.Ideal for middle to large scale device applications. Contributes to shortening the time it takes to findthe cause of failure by the switch's LED display patterns. Photocoupler monitor output allows connection to a

26、general-purpose PLC (NPN type). Compatibility with the D40A allows standardization of machine design. Compact Non-contact Door Switch can be mounted from both sides.Non-contact Door Switch Controller G9SX-NSSafety Controller G9SP SeriesFor the most recent information on ms that have been certified f

27、orsafety standards, refer to your OMRON website.MNumber StructureMNumber LegendNon-contact Door Switch (Switch/Actuator)D40Z- 1 2 31 Type2 Auxiliary OutputC: 1 NO (Photocoupler Output)3 Cable length2: 2 m5: 5 m1: Standard m(Switch/Actuator)Note: Must be used in combination with a G9SP Safety Control

28、ler or G9SX-NS Non-contact Door Switch Controller.Fors, refer to G9SP Series Catalog (Cat.No.J181) or D40A/G9SX-NS Catalog (Cat.No.C140).6Refer to “Safety Precautions” on page 14Compact non-contact Door SwitchD40ZD40ZOrdering InformationNon-contact Door SwitchNote: Must be used in combination with a

29、 G9SP Safety Controller or a G9SX-NS Non-contact Door Switch Controller.*1. Photocoupler output. Load current: 10 mANon-contact Door Switch Controller G9SX-NSNote: Fors, refer to the D40A/G9SX-NS Catalog (C140).*1. P channel MOS FET transistor output*2. The OFF-delayed output becomes an instantaneou

30、s output by setting the OFF-delay time to 0 s.*3. PNP transistor output*4. The OFF-delay time can be set in 16 steps as follows: 0/0.2/0.3/0.4/0.5/0.6/0.7/0.8/0.9/1.0/1.2/1.4/1.8/2.0/2.5/3.0 sSafety Controller G9SP SeriesNote: Fors, refer to the G9SP Catalog (F090).7NameNo. of I/O pointsUnit version

31、MSafety inputsTest outputsSafety outputsStandard outputsSafety Controller104Semiconductor outputs: 44Ver.1.0G9SP-N10S106Semiconductor outputs: 16-G9SP-N10D206Semiconductor outputs: 8-G9SP-N20SSafety outputs *1Auxiliary monitoring output *3Logical AND connection inputLogical AND connection outputOFF-

32、delayed Max. OFF-delay time *4Rated voltageTerminal block typeMInstantaneousOFF-delayed*22(Semiconductors)02(Semiconductors)11-24 VDCScrew terminalsG9SX-NS202-RTSpring-cage terminalsG9SX-NS202-RC2(Semiconductors)3.0 sScrew terminalsG9SX-NSA222-T03-RTSpring-cage terminalsG9SX-NSA222-T03-RCClassificat

33、ionAppearanceAuxiliary monitoring outputCable lengthMStandard msPhotocoupler outputs *12 mD40Z-1C25 mD40Z-1C5D40ZSpecificationsRatings and Characteristics (Non-contact Door Switch)*1. This is the distance where the switch operates from OFF to ON when approaching and the distance where the switch ope

34、rates from ON to OFF when separating when the switch and actuator target marks are on the same axis, and the sensing surface coincide. Fors, refer to“Engineering Data” on page 9.*2. Indicates the value of the non-contact door switch output.*3. Power to be provided to the load is not included.*4. For

35、s, refer to item "Precautions for Correct Use".8ItemMD40Z-1COperating characteristicsOperating distance (OFF -> ON)5 mm min. *1Operating distance (ON -> OFF)15 mm max. *1Differential travel20% or less of operating distance at 23 °C (um 2.5mm)Influence of temperature20% or less o

36、f operating distance at 23 °C within temperature range of -10 to 65 °CRepeat accuracy±10% of operating distance at 23 °CResponse time (ON -> OFF) *225 ms max.Operating time (OFF -> ON) *2100 ms max. (Distance between the switch and actuator is 5 mm)Ambient operating tempera

37、ture-10 to 65 °C (with no icing or condensation)Ambient operating humidity25% to 85%Insulation(between charged parts and case)50 MW max. (at 500 VDC)Dielectric strength (between charged parts and case)1,000 VAC for 1 minDegree of contamination3Electromagnetic compatibilityIEC/EN 60497-5-3 compl

38、iantVibration10 to 55 to 10 Hz (single amplitude: 0.75 mm, double amplitude: 1.5 mm)Shock300 m/s2 min.Degree ofIP67MaterialPBT resinMounting methodM4 screwsTerminal screw tightening torque1 N·mPower supply voltage24 V DC +10%/-15%Power consumption *30.5 W max.Auxiliary monitoring outputPhotocou

39、pler output: 24 V DC, load current: 10 mALED indicatoruator not detected (lights in red); error occurred (blinks in red), actuator detected (lights in ow), actuator detected and Non-contact Door Switch input OFF (blinks in yellow)Connecting cables2 m, 5 mNumber of connectable switches *430 max. (wir

40、ing length: 100 m max.)WeightSwitch: approx. 175 g, actuator: approx. 20 g (D40Z-1C5)D40ZEngineering DataGuaranteed value and typical data of operating characteristics15mm *5mm *0mmONOFFUnstable range* When the switch and actuator target marks are on the same axis, and the sensing surfaces coincide.

41、1818OFF rangeOFF range1616umum operating distance (ON to OFF)operating distance(ON to OFF)1414Main lobesMain lobesEngineering DataEngineering Data (ON to OFF)1212(ON to OFF)Engineering Data1010Engineering Data (OFF to ON)(OFF to ON)88MinimumMinimum operating distance (OFF to ON)operating distance66(

42、OFF to ON)44Side lobe (Y<3mm)Side lobe (Y<3mm)2ON rangeON range20030 25 20 15 10 5 0 5 10 15 20 25 3035 30 25 20 15 105 0 5 10 15 20 25 30 35Distance from the target mark on the switch Z (mm)Distance from the target mark on the switch X (mm)14Engineering Data (ON to OFF)OFFXSensing surface12ON

43、10Engineering Data (OFF to ON)86Z *Y4X=0, Z=02* The movement of the arrow direction indicates the positive direction on the graph.0Target marks10°C23°C65°CEffect of ambient temperature (°C)Note: 1.2.The operating distance is the distance between the switch and actuator sensing su

44、rfaces.Data in the diagram is typical data at an ambient temperature of 23. Actual operating values may vary. The operating distance may be affected by ambient metal, magnet catches, and temperature.Detection may occur other than on the detection surfaces of the switch and actuator. Before you use t

45、he switch and actuator, refer to “Switch and Actuator Operation” on page 17 to set the detection surfaces of the switch and actuator face to face.3.ConnectionsInternal ConnectionD40Z-1CBrownBlueWhiteBlackYellowGray9Inter nal circuit Operating distance Y (mm)Operating distance Y (mm)Operating distanc

46、e Y (mm)D40ZTroubleshooting*1.Another possible cause is a failure in internal circuit. In this case, replace with a new D40Z.Yet another possible cause is excessive noise. In this case, check and correct ambient noise environment.*2. The case where the guard door isd (Switch detectuator) is indicate

47、d.d (Switch detect*3. The case where the system stops though the guard door isuator) is indicated.10LEDindicatorCauses and corrective actions *1OFFFault in power supply input (brown/blue)Power supply input may be improperly wired. Check and correct wiring of brown and blue lines. Refer to “Wiring of

48、 Inputs and Outputs” on page 11.Power supply voltage to D40Z may be insufficient.Check the power supply voltage (between brown and blue lines) of D40Z fills ratings. Refer to “Specifications” on page 8.The wiring length or size of the wire may not be to the specification.Check the wiring length and

49、size of the wire. Refer to "Precautions for Correct Use".Red continuously blinkingNoise or D40Z failureThere may be excessive noise. Check and correct ambient noise environment.There may be a failure in internal circuit. Replace with a new D40Z.Fault in power supply input (brown/blue)Power

50、 supply voltage to D40Z may be insufficient.Check the power supply voltage (between brown and blue cables) of D40Z fills ratings. Refer to “Specifications” on page 8.The wiring length or size of the wire may not be to the specification.Check the wiring length and size of the wire. Refer to "Pre

51、cautions for Correct Use".Red blinks once for 2sFault in Non-contact door switch output (black)Black line may be shorted to other line.Check and correct wiring of black line if the black line is shorted to other lines. Refer to “Wiring of Inputs and Outputs” on page 11.Red blinks twice for 2sSe

52、nsing faultInvalid actuator may be in arange to switch. Use the dedicated actuator.Red blinks thrice for 2sFault in Non-contact door switch input (white)Faulty signal may be input to white line.Check and correct wiring of white line. Refer to “Wiring of Inputs and Outputs” on page 11.Yellow blinking

53、OFF state of another D40ZAnother D40Z may be in OFF state.Check status of another D40Z connected to the white line and the wiring.Refer to “Switch and Actuator Operation” on page 17 or “Wiring of Inputs and Outputs” on page 11.Fault in Non-contact door switch input (white)White line may be disconnected.Check and

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

最新文檔

評論

0/150

提交評論