1、6300噸瀝青船規(guī)格書第4部分-ACCOMMODATION AND AIR CONDITIONING4ACCOMMODATION AND AIR CONDITIONING24.1 ACCOMMODATION24.1.1 General24.1.2 Layout of Living Spaces34.1.3 Insulation, Deck Covering and Joinery Panels34.1.4 Ladders, Steps, Railings, Etc.84.1.5 Doors84.1.6 Windows94.1.7 Furniture104.1.8 Galley, Pantry,

2、 Dry Provision Store and Laundry Equipment154.1.9 Sanitary174.1.10 Drinking Fountain194.1.11 Mattresses194.1.12 Curtains194.2 REFRIGERATED STORE194.2.1 Refrigerated store194.2.2 Insulation and surface finishing20 4ACCOMMODATION AND AIR CONDITIONING4.1 ACCOMMODATION4.1.1 GeneralThe following spaces s

3、hall be arranged in accommodation area as shown on the General Arrangement Plan:Living spacesCabinsPublic spaces Mess roomSmoking roomGymnasium (as suez crew room also)Ship officeHospital Navigation and Wheel house with Chart space & radio space,control space Cargo and ballast control room, Engi

4、ne control room in engine roomFire control roomEmergency generator roomCO2 roomFoam stationBattery roomCorridor spacesStairway, passage wayCatering spaceGalleyPantryProvisions spacesDry provision store Bonded roomCold provision storeSanitary spacesPrivate toiletHospital toiletPublic toiletLaundry ro

5、omSundry spacesAir-conditioning unit roomPaint storeLinen lockerHydraulic pump roomOther miscellaneous stores & lockerGarbage roomOx & AC roomAll material used for interior fittings are to be of China make in general. 4.1.2 Layout of Living SpacesAccommodation to be arranged for total comple

6、ment of twenty-fivefive (255) Persons (Excluding 6 Suez Crew).RankingNumber of cabinsDescriptionLavatoryHighest officer class3Separate day, office and bed room Private lavatorySeniorofficer class2Separate day and bed roomPrivate lavatoryJuniorofficer class7Single roomPrivate lavatoryCrew class132Sin

7、gle room,Private lavatorySuez crewIn Gymnasium6 berthsPublic toiletTotal255 cabins + 1 Suez cabin4.1.3 Insulation, Deck Covering and Joinery PanelsConstruction of divisional bulkhead, lining and ceiling concerning fire protection to comply with requirements of SOLAS and Classification Society.The ar

8、rangement of walls, bulkheads, lining and ceiling in accommodation space to be in accordance with method 1C. InsulationAll panelling materials and doors in accommodation to comply with fire insulation standard and A-60 as required.Colors, patterns, texture of linings, design, colors, style an

9、d materials of furnishings to be approved by the Owner upon Builder's proposal.All internal, non-steel accommodation bulkheads and ceilings, except in public toilets, pantry, galley and laundry to be of a modular paneling system.Electric cables and sanitary pipes to be concealed, but provided wi

10、th access panels for ease of inspection, maintenance etc.Final specification under this paragraph may be adjusted at detailed design stage, however, always subject to Owner's prior approval.Accommodation block exposed to weather shall be insulated as below: ApplicationMaterialRemarkThermal insul

11、ation75 mm thick rock wool over plate 25 mm thick rock wool over beam, girder and stiffener100 mm thick rock wool underneath compass deckExposed surface of accommodation75 mm thick rock wool over plate 25 mm thick rock wool over beam, girder and stiffener + galvanized steel sheet (0.5 mm thick)Expos

12、ed surface of laundry, public toilet, dry provisions store, air conditioning unit room, electric equipment room, bonded store and other store Sound insulation50 mm thickness rock wool partition Between living spaces, office spaces, public spaces and noise generating spacesFire insulationsurface faci

13、ng to fire: 2x20mm (for steel wall) ceramic fibre felt,25mm ceramic fibre felt (for deck)According to rules and regulationsThe material of sound insulation shall be of rock wool with density of approx. 40 kg/m3.Sound insulation shall be provided as follows. -Joiner partition bulkhead, other than ste

14、el wall division, separating living space from public space -Boundaries of air-conditioning unit room facing to accommodation space.The airborne sound insulation properties shall be determined by laboratory tests in accordance with ISO standardInsulation against heat shall be omitted for the parts w

15、here steel walls are to be lined with linings of 50mm thick rockwool panel.Even though 50mm thick rock wool insulation is specified, it will be replaced by A-60 insulation in ceramic fibre felt in case A-60 insulation is required by rules.Engine control room to be sound and heat insulated with 50mm

16、thick rock wool.Side walls of fuel oil tank in which temperature be heated to more than 50OC to be heat insulated with 50mm rockwool and covered with 0.5mm galvanized steel sheet. Insulation details shall be in accordance with Builder's practice. Internal deck coveringDeck covering and fl

17、oor matting shall be generally applied as follows:MaterialRoomUnder layerTop layer8 mm thick latex type2 mm thick vinyl sheetAnti-slip type All cabins and mess room, day room, public spaces, control spaces, corridor spacesWheelhouse 30 mm thick cement5 mm thick non-slip mosaic tileSanitary spaces40

18、mm thick cement10 mm thick non-slip quarry tileCatering spaces , cold provision store,Galley, pantry, laundry50mm thick floating fire-resistance deck coveringNorament 5mm or equalEngine control room, cargo and ballast control room8mm thick latex typeNorament 5mm or equalWheelhouse50mm thick floating

19、 fireresistance deck coveringvinylAll crew cabins on main deckSpaces not mentioned in above table shall be bare steel painted.Carpets Vinyl shall be wall-to-wall except under built-in furniture.All sanitary spaces and catering spaces shall have suitable surface and have adequate slope to scupper. Ea

20、ch cover shall be rounded and applied up to 150mm high against wall from the steel deck.Other details of deck covering shall be of Builder's normal good practice and standards. Joinery, partition, lining and ceilingMaterial of wall and ceiling to be "B" class non-combustible pan

21、el.Lining: Exposed space & Engine control room:Catering space:Other space:Refrigerated store,Dry provision 50mm rockwool+galv. steel sheet coated with PVC film + galv. steel sheet for non-visible side.25mm rockwool + galv. steel sheet coated with 0.5 mm thick stainless steel sheet + galv. steel

22、sheet for non-visible side. 25mm rockwool + galv. steel sheet coated with PVC film + galv. steel sheet for non-visible side. Stainless steel sheet surfacePartition:50mm rockwool + galv. steel sheet coated with PVC film on both sides.Ceiling:Rockwool core + galv. steel sheet coated with PVC film (cat

23、ering space: Rockwool core + 0.5 mm thick stainless steel sheet).Ceiling to be panel without angle steel between ceiling and bulkhead.Engine control room perforated type.Following spaces shall be finished with joiner panel and ceiling: - Living space - Public space - Control and navigation space - C

24、orridor space - Galley, Pantry (stainless steel sheet surface) - Dry provision store, Refrigerated store (stainless steel sheet surface) - Sanitary space.Other spaces except above spaces shall not be lined with panel. Clear height in the living quarters except locker under stairway to be about 21000

25、 mm (except private sanitary wet space which is 20001900 mm) from the top of floor covering to the bottom of overhead ceiling or to that of ventilating trunk where no ceiling is applied, except protruding part such as ceiling lamp, ventilating louver and unavoidable corner bracket, etc.Perforated an

26、d galvanized steel sheet of 0.5mm thick ceiling and lining to be used for air condition room.Insulated spaces in galley, pantry and refrigerated store, dry provision store shall be sheeted with 0.5mm stainless galvanized steel sheet.Details of panels fixture shall be according to manufacturers'

27、standard or Builder's standard.4.1.4 Ladders, Steps, Railings, Etc. Wood/rubber gratingPortable wood gratings of pine shall be provided in necessary space such as stores, bridge wings according to Builder's good practice.Stores shall be provided with suitable steel shelves with wooden

28、 batten. Ladders, railings and hand rails in accommodationAccommodation stairways shall be constructed of mild steel and have clear width of 800mm and approximately 45O to 50O. Hand rail and banisters shall be constructed with of square pipe with PVC enamel paint. Non-slip toe plate of alumin

29、ium alloy shall be fitted.Storm rails of stainless steel pipe shall be fitted along one side of living quarters corridor and hard wood for wheelhouse front.Also storm rails of galvanized steel pipe of about 40mm dia. shall be provided along outside passageway of deck house.The clear width of the cor

30、ridor shall be approximately 1000mm.4.1.5 DoorsThe height up to door top above floor is to be about 1900mm.Door's clear width is to be as follows:Cabin door: 700mmCommon toilets door: 700mmPrivate toilet door: 600mmCable space and vent. pipe space door: 600mmRefrigerated store, dry provision: 80

31、0 mmWheel house stainless steel sliding sliding door with glass gas type opening outside: 1000 mm Passageway door (to be aluminium): 800mm Indicator mortise latch to be provided in toilet. Lock without cylinder to be provided at the stairway doors to corridors. Lock with three (3) master keys to be

32、provided for all other cabin door's. Three (3) keys to be provided for each cabin. Necessary mark to be marked and tagged on each key and lock cylinder.Weathertight steel doors to be used for all outside doors according to Builder's standard. The steel doors to have closing devices in non-ru

33、sting material with grease nipples for moving parts.Rain shade to be provided to doors facing weather without overhang above threshold.Sill height in accommodation to be according to Rules and Regulation.4.1.6 WindowsAll windows to be delivered with welding type aluminum alloy with steel frame.Three

34、 (3) windows with wiper on front wall of wheelhouse to be fitted with heating elements in window glasses.Two (2) windows with clean view wiper on front wall of wheelhouse be be fitted without heating elements.Wheelhouse front windows to be about 1100mm x 900mm.Wheelhouse front windows to be cleaned

35、by fresh water, hot water and compressed air.Number and actual size of windows in wheelhouse may be changed as per detailed arrangement.300mm-diameter scuttle is to be fitted for cabin and gymnasium on main deck.Windows for other cabins and galley to be rectangular windows, of 400mm x 560mm. Number

36、of windows to be in accordance with Builder's practice and to be based on detailed accommodation plans. 4.1.7 Furniture GeneralColour scheme book to be submitted to the Owner for approval.In general, the number and size of furniture to be in accordance with the specification, but may be a

37、djusted in accordance with final accommodation drawing so as to make a reasonable arrangement.Furniture and fittings to have substantial construction in harmony with decorative treatment of the space and to be in accordance with the Builder's practice.Main furniture and fittings to be as describ

38、ed in detail and the size of furniture may be changed slightly by the cabin arrangement.In general, furniture to be constructed of plywood/chipboard.Top of tea table, mess table and desk to be finished with melaminiclinoleum.Steel furniture to be of commercial stock with durable construction.The siz

39、e of steel furniture may be changed slightly to meet those of commercial stock, irrespective of the description in the specification.All furniture and heavy item which are mounted on joiner bulkhead to be secured by through bolt or to be supported by structure installed behind lining.The shape of fu

40、rniture to be of standard type and fixing arrangement of furniture to the wall, deck and/or ceiling to be in accordance with the Builder's practice.The steel leg of the table to be welded directly to the deck.The closing board to be provided for the clearance between fixed wooden furniture and f

41、loor, ceiling or side wall where inconvenient for cleaning.For upholstery;:One (1) set of cover to be provided for sofas and chairs.The material for the stuffing of sofa chair and etc. to be fire retarding treated polyurethane sponge.Upholstery for sofas and chairs to be of PVC. Dimension of

42、large furnitureCLASSBedWardrobeDeskMat.Highest officer2,000 x 1,3501,000 x 6001,700 x 800WoodSenior officer2,000 x 1,2001,000 x 6001,500 x 700WoodJunior officer2,000 x 1,000 800 x 6001,200 x 600WoodCrew2,000 x 1,000 1,200 x 6001,000 x 500WoodNote:a) Wardrobe size to be designed according to demarcat

43、ion of cabins. Life jacket locker to be fitted above wardrobe.b) All beds to be positioned longitudinally with drawers under (excluding Suez crew room).Name of sofaNormal sofaL-type sofaSize1800 x 6002000 x 1300 x 600All sofas to be positioned transversely as far as possible. CabinFurnitureHi

44、ghest OfficerSenior OfficerJunior OfficerCrewDay roomBed roomDay roomBed roomBed-1-111Wardrobe-1-111Desk1-1-11Dressing table with stool-1-1-Tea table1-1-1-Night table-1-11-Book shelf1 -1-1-Book rack-1File cabinet2-1-Safe4(captain, Owner, Radio Off. etc.)-Sofa 1 (L-type)- 1 -11Rev. arm chair1-1-Easy

45、chair-1-1-Arm chair2-2-11Waste basket1-1-11Coat hook424222Refrigerator1 (50 liter)-1(50 liter)-Note:a) Key box suitable for about 100 keys to be provided for chief officer, about 50 keys for captain, chief engineer, 2nd engineer and electric engineer.b) All cabins to have a mirror of suitable size.c

46、) TV table to be arranged in the following cabins:captain, chief officer, chief engineer, 2nd engineer, owner Public spaces(1) Mess room, day room and ship officeFurnitureMess roomDay roomShip officeMess table5-Game table-1-Meeting table-1Side board combined with TV rack and audio video locke

47、r11-File cabinet-1Arm chair-48Easy chair26-2Dresser with sink1-1Bottle cabinet11-Notice board111Coat hook14148Sofa (L type)-2-Sofa -Tea table-1-Drinking water fountain1-Above table may be changed according to final cabin's arrangement.(2) GymnasiumGymnastic device2Table-tennis table1Locker 1Benc

48、h 1Coat hook6Notice board 1Double bed (2000X800) Control spaces(1) WheelhouseFurnitureWheelhouse/Chart spaceRadio spaceChart table (with chronometer chart locker)1-Binocular box2-Log book and ballast note board1 (each)-Flag locker1-Book rack and book case1 (each)1 (book case)File cabinet (4

49、drawers)-1Radio stand-1Working table11Pilot chair2-Rev. arm chair-1Sofa1-Sounding board1-Notice board1-Pigeon hole for flag1-Direction indicator1-Folding board2-Wooden locker11Drinking water fountain1-Coat hook42(2) Cargo and ballast control room2 -Desks with computer table4 - Arm chairs1 -Filing ca

50、binets (4 drawers)1 -Book case1 -Notice board1 -Sounding board4 -Locker for fire mens equipment1 -Sideboard with 1 stainless steel sink1 -Table HospitalFurnitureHospitalSteel single bed (2000 x 1000)1Wardrobe1Night table1Arm chair1Desk1Steel stool1Medicine locker14.1.8 Galley, Pantry, Dry Pro

51、vision Store and Laundry Equipment Galley and PantryGalley1 -Galley range (with 4-hot plates cooking range) total abt 14kW.1 -Tilting frying pan (abt. 5kW)1 -Rice boiler (electric & steam)1 -Electric rice cooker (20 persons) 1 - Electric ham slicer (abt.0.2kW)1 -Food disposer (about 2kW)

52、(in stainless steel box) with sink1 -Food mixer 30 ltr with accessories (including vegetable cutter & meat miner)1 -Electric refrigerator each 180 ltr.1 -Garbage can (portable) 1 -Dresser with 2-Sink 1 -Stainless steel working table1 -Serving table with drawers1 -Hand wash basin2 - Dish rack wit

53、h cup hooks 1 - Dough table with hard wood top 1 - Flavouring shelf 1 - Locker with Shelves1 - Lid holder1 - Pot & pan rack1 - Dish washing machinePantry1 - Electric toaster, 4 slices.1 - Coffee machine (abt. 7 ltr.) 1 - Water boiler (8.0 liter)1 -Electric double hot plate (abt. 2 kw)1 -Dish sterilizer1 -Dresser with 2-Sink1 -White boardAbove equipment may be changed according to final “Galley equipment arrangement plan”.Galvanized steel grating with drainage for each door to

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
  • 4. 未經(jīng)權益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負責。
  • 6. 下載文件中如有侵權或不適當內(nèi)容,請與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

評論

0/150

提交評論