1、Liquid ChromatographyCoupled to Tandem MassSpectrometryProcessesNeeded toGenerate aMassSpectrum1) Generate desolvated ions(Sources)2) Transfer ions into massspectrometer vacuum(Interface Region)3) Mass analyze ions(Quadrupoles)4) Detect ions(Detector)5) Process the data(Software)The SourceThe Source

2、Ionization SourcesTurbo IonSpray - IonSpray (pneumaticallyassisted Electrospray) option which utilizesa heated auxiliary gas flow.Heated Nebulizer - Atmospheric PressureChemical Ionization (APCI) source whichionizes compounds in the gas phase.+-+ - -+Ion Evaporation andFormation+ + -+ - + + + -+ - -

3、 +- + + +- +-+ +IonSpray (ESI)IonSpray:- Electrospray ionization (ESI)- Gentlest ionization technique- Applicable to polar and ionic substancesIntensity,cps15+Multiply Charged Ions+Q1: from myoglobina16+etc.1060.5 1 1 3 1 .01.56e6 cps1.0e69 9 8 .09 4 2 .58 9 3 .014+1 2 1 2 .013+1 3 0 5 .05.0e58 4 8

4、.58 0 9 .012+1414.011+1542.510+1696.08001000120014001600m/z, amuMolecules which can be multiplyprotonated or deprotonated can exist inmore than one charge statePeaks at M nHn (n = number ofcharges)NebulizerCool ZonePrimary Flash ZoneSecondary Flash ZoneHeated Nebulizer(APCI)Heated Nebulizer: - Atmos

5、pheric Pressure Chemical Ionization (APCI)- corona discharge- polar to non-polar thermally stable compoundsAtmospheric Pressure ChemicalIonization (APCI)Corona Discharge Chemistry Positive Ions1) EI on atmosphere causes e- removal fromN2 & O2 forming N2+ & O2+ (primaryions)2) In a complex series of

6、reactions N2+ &O2+ react with H2O & CH3OH formingH3O+ & CH3OH2+ as reagent ions for CI.3) H3O+ & CH3OH2+ donate protons toanalyte forming M+H+AnalytePolarityGC-MS vs. LC-MSIonicIonSprayAPCINon-IonicGC-MS101102103Molecular Weight104105Ion ProductionAPI ChemistryandExample SpectraIncreasingAcidity+GAS

7、 PHASE Acid-Base Scalefor Positive Ions & Neutral MoleculesNeutral MoleculesStrong acidformic acidacetic acidwatermethanolphenolformaldehydeN2Omethaneethanebenzeneacetonitrileethyl acetateammoniatriethylamineWeak acidReagent IonsWeak BaseHCOOH2+CH3COOH2+H3O+CH3OH2+C6H6OH2+HCHOH+N2OH+CH5+C2H5C6H6H+CH

8、3CNH+C2H5OCOC2H6+NH4+C6H15NH+Strong BaseAddition of acetic acid or formic acid willincrease intensity in positive ion mode byhigher concentration of H+.Trifluoroacetic acid (TFA) works well inpositive ion mode at a concentration up to0.05%, but lingers for a long time in negativeion mode. (TFA ions

9、are at m/z 113 and m/z227dimer)Changing from acetonitrile to methanol mayincrease signal intensity.IncreasingBacicityGAS PHASE Acid-Base Scalefor Negative Ions & Neutral MoleculesNeutral moleculesWeak AcidNH3WaterTolueneMethanolEthanolAcetonitrileAcetoneCH3SHCH3NO2HCNPhenolAcetic acidBenzoic acidHCl

10、Strong AcidReagent IonsStrong BaseNH2-OH-C6H5CH2-CH3O-C2H5O-CH2CN-CH3COCH2-CH3S-CH2NO2-CN-C6H5O-CH3COO-C6H5COO-Cl-Weak BaseFor R-COOH compounds use NH4ac buffer(pH = 6.4).Try addition of NH3 in case of neutral analytesin negative ion mode.Stay away from triethylamine, it collects in thesource!Ioniza

11、tion SuppressionCompounds That Cause Sensitivity Suppression Salts can interfere with ionization and can cluster tocomplicate spectrum (but also aid in identification) Strong bases or quaternary amines can interfere withpositive mode analytes, e.g. Triethylamine (TEA) Acids - Sulfuric/Sulfonic acids

12、 and TFA interfere innegative mode experiments Phosphate buffer and non-volatile ion pairing agents (e.g.SDS) can cause severe suppression and complex spectraDimerization (2M+H+) can occur at highconcentration, leading to non-linearity duringquantitation Dimer Signal at m/z = (MW*2)+1 Can cause non-

13、linearity at high concentrationsProgesterone in Positive Ion ESI-MSM+ Na+Intensity,cpsIntensity,cps6e7Effect of Phosphate BufferQ1 MCA (10 scans): from cck q1 -ve nano254.43424.538.78e7 cps8e77e7CCK dissolved in Phosphate B uffer566.445e74e73e7733.932e7835.931e7898.221000.421 1 4 21164.6130040050060

14、070080090010001100m/z, amuQ1 MCA (10 scans): from CCK PURIFIED Q1 SACN 16.74.0e73.5e7570.444.44e7 cps3.0e72.5e72.0e71.5e7Phosphate B uffer removed from CCK sample1142.031.0e7292.82377.02439.03497.03700.63798.63879.235.0e630040050060070080090010001100m/z, amu+-+-Adducts & Clusters formed in LC/MSAddu

15、ct*/Adduct Ion FormedCauseIonicAPCIESI+/-m/z of IonLithiumM+LiAmmoniaM + NH4WaterM + H3OSodiumM + NaLithium SaltsAmmonia/NH4OHWater/AcidsSodium saltsIonicAdductAdductIonicM + H + 6M + H + 17M + H + 18M + H + 22MethanolM + H + CH3OHChlorideM + ClPotassiumM + KAcetonitrileM + H + CH3CN)Formic AcidM -

16、H + HCO2HAcetic AcidM - H + CH3CO2HTFAM - H + CF3CO2HMethanol inSolventChlorinated solventPotassium saltsAcetonitrile insolventFormic AcidAcetic AcidTFAAdductIonicIonicAdductAdductAdductAdduct+/-+/-M + H + 32M - H + 32M + 35 (& 37)M + H + 38M + H + 41M - H + 41M - H + 46M - H + 60M- H + 114* Adducts

17、 can often be broken up by using a higher DP voltage.Ion TransferIon Path“Electronic Ion Ski Slope”O(jiān)RSKIQ1Q0STRO1ST2RO2 (LINAC)ST3RO3EXIT CEMDFOR =45V0V, SK at groundMoves with C.E.Q0= -10VRO1 =-11VRO3, moves withRO2 (-2-3V)Lens (IQn) and rod (ROn) voltages are linkedKeep ions moving at correct spee

18、d through system For bestsensitivity, proper mass filteringMS &MS/MS (tandem)Quadrupole TheoryQuadrupole acts as a mass filter Separates ions based on m/z ratioQuad. made of 4 rods “A” pole - vertical rods; “B” pole -horizontal rods (by convention)DC & RF voltages are imposed: U = (DC)A - (DC)B (FDC

19、) V = RF voltage (RFp-p) V = Const.Mr022Note: M V = RF frequency r0 = distance between rodsU(DC)Operating LineStability DiagramDC/RF(through the apices) HighUnitLowV (RF)MS OperationScan ModesQ1 MS ScansStart/Stop ModeQ3 Single-Stage MS ScansStart/Stop ModeMS/MS Scan ModesAvailable Scan Modes Produc

20、t IonProvides structural information Precursor IonProvides structural information complementary toProduct Ion Neutral LossProvides compound class specificity MRMUsed for QuantitationIn all MS/MS modes, Q3 is a mass filter Q3 may scan or be fixed at a given m/z Q2 is “source” of product ions entering

21、 Q3MS/MS Product Ion Scanm1+ fixedm3+ scannedMS/MS Precursor Ion Scanm1+ scannedm3+ fixedMS/MS Neutral Loss Scanm1+ scannedmm3+ scannedMS/MS MRM(Multiple Reaction Monitoring)Precursor ionfixedFragmentation(CAD)Product ionfixedFragmentationWhen an ion fragments the following formulas apply: Positive mode: N

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

最新文檔

評論

0/150

提交評論