建筑給排水工程給排水及泵站設(shè)計(jì)說(shuō)明書(shū)太原理工大學(xué)現(xiàn)代科技學(xué)院任務(wù)書(shū)專(zhuān)業(yè)班級(jí)環(huán)境工程1001學(xué)生姓名張澤乾課程名稱(chēng)輸水工程與泵站大同市J3縣給設(shè)計(jì)名稱(chēng)設(shè)計(jì)周數(shù)2周指導(dǎo)教師蘇冰琴水與排水管網(wǎng)設(shè)計(jì)設(shè)計(jì)給水設(shè)計(jì)資料:任務(wù)1.J3縣地形圖(比例尺1:5000)主要2.縣區(qū)總?cè)丝冢?.8萬(wàn)用水人口:100%設(shè)計(jì)3.縣區(qū)房屋層數(shù):6參數(shù)4.給水管道排管單價(jià):c10(每米長(zhǎng)管線造價(jià)費(fèi)為c=24.6+249D1.7)5.工業(yè)企業(yè)情況(1)電廠工作時(shí)間:第一班0-8,第二班8-16,第三班16-24冷車(chē)間人數(shù):12000人/日熱車(chē)間人數(shù):9000人/日淋浴用水:5000人/班生產(chǎn)用水量:8000噸/日(2)車(chē)輛廠工作時(shí)間:第一班8-16,第二班16-24冷車(chē)間人數(shù):8000人/日熱車(chē)間人數(shù):6000人/日淋浴用水:3000人/班生產(chǎn)用水量:6000噸/日6.投資償還期:5年7.每年扣除的折舊和大修費(fèi):p=5%排水設(shè)計(jì)資料:1.1:5000比例尺縣區(qū)總平面圖一張,圖中每隔一米的等高線2.縣區(qū)人口密度:520人/公頃3.排入縣區(qū)管網(wǎng)的工廠有企業(yè)甲、乙等甲工廠污水排放量:500m3/d乙工廠污水排放量:1000m3/d4.縣區(qū)土壤冰凍深度:0.8m5.地下水位:6m6.徑流系數(shù):ψ=0.67.污水處理廠沉沙池水位:110m設(shè)計(jì)內(nèi)容給水管網(wǎng)設(shè)計(jì)要求:設(shè)計(jì)要求1.根據(jù)所給資料,確定取水建筑和凈水建筑的地點(diǎn);2.分析全縣用水量和一天內(nèi)流量變化情況,決定清水池容積;3.計(jì)算界限流量和經(jīng)濟(jì)因素4.確定J3縣主要供水方向,并進(jìn)行管網(wǎng)定線;5.初步分配流量,確定管徑;6.進(jìn)行管網(wǎng)平差;7.繪制管網(wǎng)平面圖;8.整理報(bào)告裝訂成冊(cè)。報(bào)告應(yīng)力求文字通順,字跡清楚;排水管網(wǎng)設(shè)計(jì)要求:1.排水體制選擇2.縣區(qū)排水管網(wǎng)定線3.設(shè)計(jì)流量計(jì)算4.污水主干管的水力計(jì)算5.任選一條雨水管路進(jìn)行水力計(jì)算6.繪制管網(wǎng)總平面圖、主干管的縱剖面圖7.泵站流量、揚(yáng)程計(jì)算8.泵站吸、壓水管路計(jì)算9.泵站機(jī)組、管路布置10.泵站平面尺寸和高度計(jì)算11.繪制泵站詳圖12.整理報(bào)告裝訂成冊(cè)。報(bào)告應(yīng)力求文字通順,字跡清楚1.《給水排水設(shè)計(jì)手冊(cè)》第1、11、12冊(cè);2.《給水工程》教材主要參考3.《排水工程》上冊(cè)資料4.《泵與泵站》5.簡(jiǎn)明給水設(shè)計(jì)手冊(cè)學(xué)生提交1.給水管網(wǎng)、排水管網(wǎng)設(shè)計(jì)任務(wù)書(shū)1份歸檔文件2.給水管網(wǎng)說(shuō)明書(shū)1份3.縣區(qū)給水管網(wǎng)總平面布置圖一份4..排水管網(wǎng)設(shè)計(jì)說(shuō)明書(shū)1份5.縣區(qū)排水水管網(wǎng)總平面布置圖一份6.排水管網(wǎng)主干管縱剖面圖一份7.泵站詳圖注:1.課程設(shè)計(jì)完成后,學(xué)生提交的歸檔文件應(yīng)按照:封面—任務(wù)書(shū)—說(shuō)明書(shū)—圖紙的順序進(jìn)行裝訂上交(大張圖紙不必裝訂)2.可根據(jù)實(shí)際內(nèi)容需要續(xù)表,但應(yīng)保持原格式不變。指導(dǎo)教師簽名:日期:給水管網(wǎng)課程設(shè)計(jì)說(shuō)明書(shū)目錄第一章設(shè)計(jì)資料………………..5第二章設(shè)計(jì)要求………………..5第三章用水量計(jì)算…………......5第四章界限流量計(jì)算………….6第五章管網(wǎng)定線………………..7第六章水力計(jì)算………………..7第七章管網(wǎng)平差計(jì)算和校核…………………9第八章參考資料…………...….11附表1J3縣最高日用水量計(jì)算表…………….12附圖1J3縣用水量變化曲線…………………13附表2界限流量表……………..15附表3管網(wǎng)平差計(jì)算表………..16附表4-1、4-2消防時(shí)管網(wǎng)平差計(jì)算結(jié)……………..18附表5-1、5-2事故時(shí)管網(wǎng)平差計(jì)算結(jié)……………..19第一章設(shè)計(jì)資料一、J3縣地形圖(比例尺1:5000)二、縣區(qū)總?cè)丝冢?.8萬(wàn)用水人口:100%三、縣區(qū)房屋層數(shù):6四、給水管道排管單價(jià):c10(每米長(zhǎng)管線造價(jià)費(fèi)為c=24.6+249D1.7)五、工業(yè)企業(yè)情況(1)電廠工作時(shí)間:第一班0—8,第二班8—16,第三班16—24冷車(chē)間人數(shù):12000人/日熱車(chē)間人數(shù):9000人/日淋浴用水:5000人/3000人/班;熱車(chē)間人數(shù):2000人/班)生產(chǎn)用水量:8000噸/日(2)車(chē)輛廠工作時(shí)間:第一班8—16,第二班16—24冷車(chē)間人數(shù):8000人/日熱車(chē)間人數(shù):6000人/日淋浴用水:3000人/2000人/班;熱車(chē)間人數(shù):1000人/班)生產(chǎn)用水量:6000噸/日六、投資償還期:5年七、每年扣除的折舊費(fèi)和大修費(fèi):p=5%第二章設(shè)計(jì)要求一、根據(jù)所給資料,確定取水構(gòu)筑物和凈水構(gòu)筑物的地點(diǎn)。二、分析全縣用水和一天內(nèi)流量變化情況,確定清水池容積。三、計(jì)算界限流量和經(jīng)濟(jì)因素。四、確定J3縣區(qū)主要供水方向,并進(jìn)行管網(wǎng)定線。五、初步分配流量,確定管徑。六、進(jìn)行管網(wǎng)平差。七、繪制管網(wǎng)平面圖八、整理設(shè)計(jì),訂裝成冊(cè)。報(bào)告應(yīng)力求文字通順,字跡清楚第三章用水量計(jì)算一、城市或居住區(qū)最高日綜合生活用水量Q1按居住條件,總?cè)丝诩s為8.8萬(wàn),屬于中小城市,則可查《給水工程》教材附表1(b150—240L/人·d200L/人·dQ1=qNf(m3/d)=200×88000×100%×10-3=17600m3/d二、最高日工業(yè)企業(yè)職工的生活用水和淋浴用水量Q2車(chē)間職工生活用水標(biāo)準(zhǔn):熱車(chē)間取35L/人·班;冷車(chē)間取25L/人·班車(chē)間職工淋浴用水標(biāo)準(zhǔn):熱車(chē)間取60L/人·班;冷車(chē)間取40L/人·班1、電廠職工生活用水量:熱車(chē)間:Q=3000×3×35×10-3=315m3/d冷車(chē)間:Q=4000×3×25×10-3=300m3/dQ=315+300=615m3/d淋浴用水量:熱車(chē)間:Q=3000×3×60×10-3=540m3/d冷車(chē)間:Q=2000×3×40×10-3=240m3/dQ=540+240=780m3/d2、車(chē)輛廠職工生活用水量:熱車(chē)間:Q=3000×2×35×10-3=210m3/d冷車(chē)間:Q=4000×2×25×10-3=200m3/d車(chē)輛廠職工生活用水量:Q=210+200=410m3/d淋浴用水量:熱車(chē)間:Q=2000×2×60×10-3=240m3/d冷車(chē)間:Q=1000×2×40×10-3=80m3/d車(chē)輛廠職工淋浴用水量:Q=240+80=320m3/d最高日工業(yè)企業(yè)職工的生活用水和淋浴用水量Q2=615+780+410+320=2125m3/d三、最高日生產(chǎn)用水量Q3最高日生產(chǎn)用水量=最高日電廠生產(chǎn)用水量+最高日車(chē)輛廠生產(chǎn)用水量Q3=8000+6000=14000m3/d四、未預(yù)見(jiàn)水量與管網(wǎng)漏水量Q4(以最高日用水量的20%計(jì)算)Q4=20%×(Q1+Q2+Q3)=20%×(17600+2125+14000)=6745m3/d五、最高日用水量:Qd=Q1+Q2+Q3+Q4=17600+2125+14000+6745=40470m3/d六、J3縣用水量計(jì)算表(附表1-1)七、最高日逐時(shí)變化曲線(附圖1-1)八、清水池容積計(jì)算:根據(jù)最高日用水變化曲線和一級(jí)泵站供水曲線可求得清水池容積V=[(5.78-4.16)+(5.08-4.17)+(4.77-4.17)+(4.81-4.16)+(4.84-4.17)+(4.78-4.17)+(4.86-4.16)+(4.97-4.17)+(6.16-4.17+(5.07-4.165.01-4.17+(4.74-4.17×40470/100=4402.73m3第四章界限流量計(jì)算一、根據(jù)每米管線造價(jià)c=24.6+249D1.7可得:a=24.6b=249α=1.7二、求經(jīng)濟(jì)因素m=5.33p=5%k=1.743×10-9t=5α=1.7η=70%β=0.4~0.5E=40分/度b=249fmPkp100bt5.331965.711.743109510052491.71.731099三、界限流量(見(jiàn)附表1-2)第五章管網(wǎng)定線1、定線原則(1)干管延伸方向應(yīng)和二級(jí)泵站輸水到水池、水塔、大用戶(hù)的水流方向一致(2)干管間距根據(jù)街區(qū)采用500-800米(3)干管之間的連接管使管網(wǎng)形成環(huán)狀網(wǎng),連接管間距情況定位800-1000m(4)在供水范圍道路下,需設(shè)分配管,以便把干管的水送到用戶(hù)和消防栓,分配管徑最小為100mm,大城市采用150mm-200mm(5)干管上消火栓間距80m-120m,閘閥500m-1000m(6)綜合考慮分期建設(shè)、發(fā)展情況及經(jīng)濟(jì)技術(shù)、安全等因素2、實(shí)際定線(1)利用重力流,取水廠設(shè)在河流上游(2)供水由西向東,保證電廠和車(chē)輛廠的用水(3)盡量減少拐彎,以減少水頭損失(4)為保證供水安全,布置成環(huán)狀網(wǎng)(5)泵站布置在高水坡上,利用重力流達(dá)到減少造價(jià)的目的(6)考慮到縣區(qū)的發(fā)展,某些管道單側(cè)供水(7)管網(wǎng)鋪設(shè)在街區(qū)的道路下面(8)詳圖見(jiàn)《城市管網(wǎng)定線圖》第六章水力計(jì)算一、沿線流量與節(jié)點(diǎn)流量1、比流量的計(jì)算依據(jù)公式:qs——比流量(L/(s·m))Q——管網(wǎng)總用水量(L/s)Σq——大用戶(hù)集中用水量總和(L/s)ΣL1——m)Q-Σq=Q生+Q未預(yù)=1012.00+281.04=1293.04m3/h=359.18L/sJ3時(shí)用水量為6.12%的16-17時(shí)的居民綜合生活用水Q生和未預(yù)見(jiàn)水量Q未預(yù)qs=359.18/8590=0.042(L/(s·m))Σq=Q-359.18==333.17L/s2、沿線流量計(jì)算:q1=qslili——管段長(zhǎng)度表1-6-1沿線流量計(jì)算表編號(hào)1-21-42-32-53-64-54-75-65-86-97-88-9m)770620810680670760685770670660745750q1(L/s)32.3426.0434.0228.5628.1431.9228.7732.3428.1427.7231.2931.53、節(jié)點(diǎn)流量的計(jì)算:qi=αΣq1=αqsΣl1α=0.5表1-6-2節(jié)點(diǎn)流量計(jì)算表節(jié)點(diǎn)號(hào)123456789總計(jì)節(jié)點(diǎn)流量44.145.4

29.1947.4631.0843.3760.4830.0329.61360.78

qi(L/s)074、初步分配流量在環(huán)狀管網(wǎng)流量分配時(shí),流向任意節(jié)點(diǎn)的流量,必須等于流出該節(jié)點(diǎn)的流量,以保證水流的連續(xù)性。即:Qi+∑qij=0式中:Qi—i節(jié)點(diǎn)的節(jié)點(diǎn)流量(L/s)∑qij—節(jié)點(diǎn)i到節(jié)點(diǎn)j的管段流量進(jìn)入管網(wǎng)總用水量為Σq+qi=333.17+360.78=693.95L/s初步分配流量圖如下:圖1-1初步流量分配圖5、根據(jù)初步分配流量確定管徑表1-6-3界限流量表管徑(m)0.100.150.200.250.300.350.40界限流量(L/s)<5.775.77~13.3013.30~24.5124.51~39.4739.74~59.1059.10~82.9182.91~110.76管徑(m)0.450.500.600.700.800.90界限流量(L/s)110.76~145.11145.11~201.12201.12~298.55298.55~419.87419.87~565.04>565.04由此可得表1-6-4各管段管徑一覽表管段號(hào)1-22-31-42-53-64-55-64-75-86-97-88-9mm)500500600200600600450600250450500500調(diào)整后500500600250600600450600300450500500mm)說(shuō)明:①根據(jù)界限流量確定管徑②綜合考慮安全因素和事故時(shí)保證70%管網(wǎng)平差結(jié)果見(jiàn)附表1-3和附圖1-2第七章管網(wǎng)平差計(jì)算和校核一、管網(wǎng)平差計(jì)算1、管網(wǎng)平差的目的、要求管網(wǎng)分配流量時(shí)應(yīng)滿(mǎn)足節(jié)點(diǎn)處Qi+∑qij=0的要求,但由于某些管徑的放大和采用了標(biāo)準(zhǔn)管徑,所以出現(xiàn)了平差計(jì)算,使得△h=0,管網(wǎng)平差的目的是校核流量使之滿(mǎn)足上述兩要求。平差結(jié)果要求小環(huán)△h<0.5,大環(huán)△H<1.02、沿線流量的計(jì)算、節(jié)點(diǎn)流量的計(jì)算見(jiàn)表6-1、表6-2;3、進(jìn)行管網(wǎng)平差。管網(wǎng)平差計(jì)算表見(jiàn)附表三4、經(jīng)過(guò)三次校正后,各環(huán)閉合差如下:(1)各小環(huán)的閉合差:△hⅠ=-0.0678<0.5△hⅡ=-0.3237<0.5△hⅢ=-0.2343<0.5△hⅣ=-0.1826<0.5大環(huán)4-1-2-3-6-9-8-7-4的閉合差:∑h=h4-1+h1-2+h2-3+h3-6+h6-9-+h9-8+h8-7+h7-4=0.7507+1.7547+1.4194-0.8181-0.9255-0.9885-1.3246-0.6811=-0.8102<1.0,符合設(shè)計(jì)要求。二、校核(1)消防時(shí)校核38.8區(qū)室外的消防用水量以同一時(shí)間內(nèi)的火災(zāi)次數(shù)為2次計(jì)算,且一次滅火用水量以35L/s計(jì)算,則消防時(shí)沿線流量和節(jié)點(diǎn)流量發(fā)生變化,變化后的流量如下表:表1-7-1沿線流量計(jì)算表(消防)編號(hào)1-21-42-32-53-64-54-75-65-86-97-88-9m)770620810680670760685770670660745750q132.3426.0434.0228.5628.1431.9228.7732.3428.1427.7231.2931.5(L/s)表1-6-6節(jié)點(diǎn)流量計(jì)算表(消防)節(jié)點(diǎn)123456789總計(jì)號(hào)節(jié)點(diǎn)流量29.1947.4631.0843.3760.4844.1030.0345.4729.61360.78qi(L/s)消防時(shí)校核平差計(jì)算結(jié)果見(jiàn)附表1-4-1、1-4-2和附圖1-3(2)事故時(shí)校核事故時(shí)大用戶(hù)流量按原來(lái)的70%計(jì)算,即:333.17×70%=233.22(L/s)因流量最大的管段4-5發(fā)生事故,故沿線流量和節(jié)點(diǎn)流量發(fā)生變化,又有qs=359.18×70%/(8590-7600.03213(L/(s·m)表:表1-7-2沿線流量計(jì)算表(事故)編號(hào)1-21-42-32-53-64-75-65-86-97-88-9長(zhǎng)度770620810680670685770670660745750(m)q124.74019.92126.02521.84821.52722.00924.74021.52721.20623.93724.098(L/s)表1-7-3節(jié)點(diǎn)流量計(jì)算表(事故)節(jié)點(diǎn)123456789總計(jì)號(hào)節(jié)點(diǎn)流量22.33036.30723.77620.96534.05833.73722.97334.78122.652251.578qi(L/s)事故時(shí)管網(wǎng)平差計(jì)算結(jié)果見(jiàn)附表1-5-1、1-5-2和附圖1-4第八章參考資料1.《給水排水設(shè)計(jì)手冊(cè)》第1冊(cè);2.《給水工程》教材(1999年12月第四版主審:許保玖;中國(guó)建筑工業(yè)出版社)J3縣最高日用水量計(jì)算表附表1-1時(shí)間居民生活綜合用水電廠車(chē)輛廠占一天用水量高溫車(chē)間生活用水量一般車(chē)間生活用水量生產(chǎn)用水淋浴用水高溫車(chē)間生活用水量一般車(chē)間生活用水量生產(chǎn)用水淋浴用水未預(yù)見(jiàn)水量每小時(shí)用水量%m3變化系數(shù)m3變化系數(shù)m3m3m3變化系數(shù)m3變化系數(shù)m3m3m3m3m3%0--11.70299.203216.837.518.75333.342603216.837.518.75160281.041404.683.471--21.67293.921212.66.256.25333.33281.04927.142.292--31.63286.881212.612.512.5333.33281.05926.362.293--41.63286.881212.612.512.5333.34281.04926.362.294--52.56450.561212.618.7518.75333.33281.051096.292.715--64.35765.601212.66.256.25333.33281.041398.823.466--75.14904.641212.612.512.5333.34281.051544.133.827--85.64992.641212.612.512.5333.33281.041632.114.038--96.001056.003216.837.518.75333.33260375281.042340.925.789--105.841027.841212.66.256.25333.341212.66.256.25375281.042054.925.0810--115.07892.321212.612.512.5333.331212.612.512.5375281.041931.894.7711--125.15906.401212.612.512.5333.331212.612.512.5375281.041945.974.8112--135.15906.401212.618.7518.75333.341212.618.7518.75375281.041958.484.8413--145.15906.401212.66.256.25333.331212.66.256.25375281.041933.474.7814--155.27927.521212.612.512.5333.331212.612.512.5375281.041967.094.8615--165.52971.521212.612.512.5333.341212.612.512.5375281.042011.104.9716--175.751012.003216.837.518.75333.332603216.837.518.75375160281.042492.476.1617--185.831026.081212.66.256.25333.331212.66.256.25375281.042053.155.0718--195.62989.121212.612.512.5333.341212.612.512.5375281.042028.705.0119--205.00880.001212.612.512.5333.331212.612.512.5375281.041919.574.7420--213.19561.441212.618.7518.75333.331212.618.7518.75375281.041613.513.9921--222.69473.441212.66.256.25333.341212.66.256.25375281.041500.523.7122--232.58454.081212.612.512.5333.331212.612.512.5375281.041493.653.6923--241.87329.121212.612.512.5333.331212.612.512.5375281.051368.703.38總計(jì)1001760031530080007802102006000320674540470.00100附圖1-1J3縣用水量變化曲線Di(m)0.100.150.200.250.300.350.400.450.500.600.700.800.90Diα0.0200.0400.0650.0950.1290.1680.2110.2570.3080.4200.5450.6840.8362.142.465.32×1.626.122.691.32Di-m70.5340.2215.226.693.281.75

×105×104103×103×102×102×102界限流量表附表1-2最高日用水量管網(wǎng)計(jì)算表附表1-3初步分配流量第一次校正環(huán)號(hào)管段管長(zhǎng)(m)管徑(mm)q(L/s)1000ih(m)|sq|q(L/s)1000ih(m)|sq|1-2770500181.61002.34221.80350.0099179.08092.28501.75950.00984-1620600210.80001.23800.76760.0036208.27091.21000.75020.0036ⅠDnα-Dn-1α0.0200.0250.0300.0340.0390.0430.0460.0510.1120.1250.1390.1521.89×1.93×3.70×1.01×3.43×1.37×Dn-1-m-Dn-m61.4730.3125.008.533.411.53

1051041031031021021.22×103q界=(L/s)5.7713.3024.5139.7459.1082.91110.76145.11201.12298.55419.8756523.40001.7540-1.19270.0510-21.82801.5270-1.03840.04764-5760600-220.60001.3530-1.02830.0047-238.24341.5520-1.17950.00500.35010.06920.29180.0659△qⅠ=-△hⅠ/2∑(sq)Ⅰ=-2.5291△qⅠ’=-△hⅠ’/2∑(sq)Ⅰ’=-2.21212-3810500157.55001.80101.45880.0093153.44881.71701.39080.0091Ⅱ5-268025023.40001.75401.19270.051021.82801.52701.03840.04766-3670600-206.69001.1970-0.80200.0039-210.79121.2370-0.82880.00395-6770450-111.22001.6010-1.23280.0111-138.50422.4151-1.85960.01340.61680.0752-0.25930.0740△qⅡ=-△hⅡ/2∑(sq)Ⅱ=-4.1012△qⅡ’=-△hⅡ’/2∑(sq)Ⅱ’=1.75234-5760600220.60001.35301.02830.0047238.24341.55201.17950.0050Ⅲ4-7685600-219.18001.3360-0.91520.0042-204.06581.1710-0.80210.00395-867030025.50000.82100.55010.021617.43120.41780.27990.01617-8745500-189.15002.5280-1.88340.0100-174.03582.1608-1.60980.0092-1.22020.0404-0.95250.0342△qⅢ=-△hⅢ/2∑(sq)Ⅲ=15.1142△qⅢ’=-△hⅢ’/2∑(sq)Ⅲ’=13.92845-6770450111.22001.60101.23280.0111138.50422.41511.85960.0134Ⅳ6-9660450-139.57002.4470-1.61500.0116-116.38701.7416-1.14950.00995-8670300-25.50000.8210-0.55010.0216-17.43120.4178-0.27990.01618-9750500-169.18002.0540-1.54050.0091-145.99701.5699-1.17750.0081-2.47280.0533-0.74720.0474△qⅣ=-△hⅣ/2∑(sq)Ⅳ=23.1830△qⅣ’=-△hⅣ’/2∑(sq)Ⅳ’=7.8773續(xù)表第二次校正第三次校正環(huán)號(hào)管段管長(zhǎng)(m)管徑(mm)q(L/s)1000ih(m)|sq|q(L/s)1000ih(m)|sq|1-2770500176.86872.23171.71840.0097178.902.281.760.01Ⅰ4-1620600206.05871.19100.73840.0036208.091.210.75025.79242.0909-1.42180.0551-23.681.79-1.220254.38381.7551-1.33390.0052-256.061.78-1.350.01-0.29890.0737-0.060.072.02850.432-3810500155.20111.75401.42080.0092155.121.751.420.01Ⅱ5-268025025.79242.09091.42180.055123.681.791.220209.03891.2203-0.81760.0039-209.121.22-0.820144.62932.6120-2.01120.0139-149.932.80-2.150.010.01370.0821-0.330.08-0.08372.124-5760600254.38381.75511.33390.0052256.061.781.350.01Ⅲ4-7685600-190.13741.0314-0.70650.0037-186.430.99-0.680.005-867030023.48220.70610.47310.020121.970.630.420160.10741.8527-1.38030.0086-156.401.78-1.320.01-0.27980.0377-0.230.043.70833.075-6770450144.62932.61202.01120.0139149.932.802.150.01Ⅳ6-9660450-108.50961.5327-1.01160.0093-103.291.40-0.93023.48220.7061-0.47310.0201-21.970.63-0.420138.11961.4124-1.05930.0077-132.901.32-0.990.01-0.53270.0510-0.180.055.21831.81大環(huán)4-1-2-3-6-9-8-7-4的閉合差:∑h=h4-1+h1-2+h2-3+h3-6+h6-9-+h9-8+h8-7+h7-4=0.7507+1.7547+1.4194-0.8181-0.9255-0.9885-1.3246-0.6811=-0.8102<1.0,符合附圖1-2最高日用水量計(jì)算圖消防時(shí)管網(wǎng)節(jié)點(diǎn)計(jì)算表附表1-4-1編號(hào)地面標(biāo)高已知水壓已知流量節(jié)點(diǎn)水壓自由水頭節(jié)點(diǎn)流量1104.2029.19115.28711.08729.1902101.5047.46113.29111.79147.460398.65399.24111.60612.956399.2404105.17-720.59116.09010.920-720.5905102.2060.48114.56312.36360.480699.4544.10112.42712.97744.1007105.34115.34115.34010.00065.0418102.3545.47114.31911.96945.470999.6529.61113.35313.70329.610消防時(shí)管網(wǎng)管段計(jì)算表附表1-4-2編號(hào)管徑長(zhǎng)度阻力系數(shù)起始節(jié)點(diǎn)終止節(jié)點(diǎn)流量流速水力坡度水頭損失10.57700.01312198.48951.01092.59251.996220.58100.01323177.78800.90552.07991.684730.66200.01314-227.68000.80531.2955-0.803240.256800.01325-26.75840.54511.8709-1.272250.66700.01336-221.45180.78321.2256-0.821160.67600.01345283.56541.00292.00951.527270.457700.01356155.20750.97592.77372.135880.66850.01347209.34430.74041.09520.750290.46700.0135841.11980.32720.36390.2438100.456600.01369-110.34370.69381.4020-0.9253110.57450.01378144.30350.73491.37021.0208120.57500.01389139.95370.71281.28890.9667附圖1-3消防時(shí)管網(wǎng)計(jì)算圖事故時(shí)管網(wǎng)管段計(jì)算表附表1-5-1編號(hào)管徑長(zhǎng)度阻力系數(shù)起始節(jié)點(diǎn)終止節(jié)點(diǎn)流量流速水力坡度水頭損失10.57700.01312209.24571.06572.88112.218420.58100.01323152.28910.77561.52611.236130.66200.01314-231.57610.81901.3402-0.830940.256800.0132520.64980.42071.11420.757650.66700.01336-104.70580.37030.2740-0.183660.457700.0135657.67520.36260.38300.294970.66850.01347233.22400.82491.35940.931280.46700.01358-71.08380.56571.0875-0.728790.456600.01369-80.76710.50780.7511-0.4957100.57450.01378209.28371.06592.88212.1472110.57500.01389103.41910.52670.70380.5278事故時(shí)管網(wǎng)節(jié)點(diǎn)計(jì)算表附表1-5-2編號(hào)地面標(biāo)高已知水壓已知流量節(jié)點(diǎn)水壓自由水頭節(jié)點(diǎn)流量1104.222.330133.44029.24022.3302101.536.307131.22229.72236.307398.65256.995129.98631.336256.9954105.17-464.800134.27129.101-464.8005102.234.058130.46428.26434.058699.4533.737130.16930.71933.7377105.34133.34133.34028.00023.9408102.3534.781131.19328.84334.781999.6522.652130.66531.01522.652附圖1-4事故時(shí)管網(wǎng)計(jì)算圖排水管網(wǎng)與泵站課程設(shè)計(jì)說(shuō)明書(shū)目錄第一章設(shè)計(jì)資料…………..22第二章設(shè)計(jì)要求…………..22第三章污水管網(wǎng)設(shè)計(jì)……..22第四章雨水管網(wǎng)設(shè)計(jì)……..24第五章污水與泵站設(shè)計(jì)…………………..26附表一污水干管設(shè)計(jì)流量計(jì)算表………..33附表二污水主干管水力計(jì)算表…………..34附表三雨水干管水力計(jì)算表……………..35第一章設(shè)計(jì)資料1.1:5000比例尺縣區(qū)總平面圖一張,圖中每隔一米的等高線2.縣區(qū)人口密度:520人/公頃3.排入縣區(qū)管網(wǎng)的工廠有企業(yè)甲、乙等甲工廠污水排放量:500m3/d乙工廠污水排放量:1000m3/d4.縣區(qū)土壤冰凍深度:0.8m5.地下水位:6m6.徑流系數(shù):ψ=0.67.污水處理廠沉沙池水位:110m第二章設(shè)計(jì)要求1.排水體制選擇2.縣區(qū)排水管網(wǎng)定線3.設(shè)計(jì)流量計(jì)算4.污水主干管的水力計(jì)算5.任選一條雨水管路進(jìn)行水力計(jì)算6.繪制管網(wǎng)總平面圖、主干管的縱剖面圖7.泵站流量、揚(yáng)程計(jì)算8.泵站吸、壓水管路計(jì)算9.泵站機(jī)組、管路布置10.泵站平面尺寸和高度計(jì)算11.繪制泵站詳圖12.整理報(bào)告裝訂成冊(cè)。報(bào)告應(yīng)力求文字通順,字跡清楚第三章污水管網(wǎng)設(shè)計(jì)一、污水管道布置觀察街坊平面圖可知地勢(shì)自西向東傾斜,坡度較小無(wú)明顯分水線,所以劃分一個(gè)排水區(qū)。為使污水能在管線較短和埋深較淺情況下自流排出,街道支管布置在街坊地勢(shì)較低一側(cè),干管基本上與等高線垂直,主干管布置在縣區(qū)東面,基本與等高線平行,所以二、街區(qū)編號(hào)及面積街區(qū)面積表2-3-1街區(qū)街區(qū)面街區(qū)編街區(qū)面街區(qū)編街區(qū)面街區(qū)編街區(qū)面編號(hào)積(ha)號(hào)積(ha)號(hào)積(ha)號(hào)積(ha)12.80193.63373.90554.7023.41204.08385.42562.9033.82214.27395.14574.3243.82223.02405.44584.2853.34232.72415.23594.3263.30242.82423.60604.1872.52254.30433.83614.2081.83264.12443.64624.5690.70272.74455.25634.10103.74285.72465.16644.55115.13295.45474.11654.71124.83306.06484.80664.60133.68315.25494.62674.73143.68323.80504.72684.50153.10333.30514.71694.73164.96343.48524.72705.04175.27355.44534.62714.84184.00365.72544.34724.86三、劃分設(shè)計(jì)管段,計(jì)算設(shè)計(jì)流量1520人/ha303.22ha8.8查表得綜合生活用水定額為110~180L/(cap·d),取150L/(cap·d)。在按用水定額確定污水定額時(shí),對(duì)給排水系統(tǒng)完善的地區(qū)可按用水定額的90%計(jì)算,一般地區(qū)可按用水定額的80%計(jì)算。因?yàn)楸緟^(qū)用水不完善,所以污水定額為:150×80%=120L/(cap·d)計(jì)算面積比流量L/(s·ha)2、計(jì)算集中流量?jī)善髽I(yè)排入縣區(qū)管網(wǎng)的污水設(shè)計(jì)流量:甲企業(yè):Q1==5.787L/s乙企業(yè):Q2==11.574L/s3、根據(jù)設(shè)計(jì)管段定義將1點(diǎn)定為起點(diǎn),定出設(shè)計(jì)管段的路線及檢查井的位置并將其編號(hào),按轉(zhuǎn)輸面積和本段排水面積及比流量按Q=Kz×F×q0(Kz=)管段設(shè)計(jì)流量計(jì)算見(jiàn)附表一。四.水力計(jì)算1.從圖上量各管段的長(zhǎng)度L和起始點(diǎn)地面標(biāo)高。2.計(jì)算地面坡度作為管道坡度的參考。3.根據(jù)附表二所得設(shè)計(jì)流量和自己設(shè)定的管徑,查《給排水設(shè)計(jì)手冊(cè)第一冊(cè)》的鋼筋混凝土圓管(非滿(mǎn)流,n=0.014)水力計(jì)算表,查其對(duì)應(yīng)的I、v、v和管徑DD300mm,v0.6m/sD和設(shè)計(jì)充滿(mǎn)的關(guān)系如下表:最大設(shè)計(jì)充滿(mǎn)度表2-3-2管徑(D)或暗渠高(H)(mm)最大設(shè)計(jì)充滿(mǎn)度(或)200~3000.55350~4500.65500~9000.70≥10000.754.計(jì)算結(jié)果見(jiàn)附表二5.計(jì)算管段上下端水面及管底標(biāo)高和管道埋設(shè)深度。a、降落量△H=L·Ib、設(shè)計(jì)水深c、根據(jù)地形管網(wǎng)布置確定管網(wǎng)系統(tǒng)埋深控制點(diǎn);d、計(jì)算埋設(shè)深度。水力計(jì)算后將管徑、坡度、管長(zhǎng)標(biāo)于街坊平面圖上五.進(jìn)行水力計(jì)算時(shí)要注意:1必須細(xì)致研究管道系統(tǒng)的控制點(diǎn)2必須細(xì)致研究管道輻射坡度與管線經(jīng)過(guò)地段的地面坡度之間的關(guān)系3水力計(jì)算自上游依次向下游管段進(jìn)行,一般情況下隨著設(shè)計(jì)流量逐段增加,設(shè)計(jì)流速應(yīng)相應(yīng)增加,設(shè)計(jì)流速應(yīng)相應(yīng)增加。若流量保持不變,流速不應(yīng)減少4在地面坡度太大的地段,為減少管內(nèi)水流速度防止管壁被沖刷管段坡度往往小于地面坡度5同一點(diǎn)上游水面標(biāo)高必須等于或高于下游水面標(biāo)高,同一點(diǎn)上游管內(nèi)底標(biāo)高須等于或高于下游管內(nèi)底標(biāo)高6水流通過(guò)檢查井常會(huì)引起局部水頭損失,因此要?jiǎng)?chuàng)造良好水利條件檢查井底部應(yīng)盡量采用直管,轉(zhuǎn)彎處要采用均勻彎曲管7在旁側(cè)管與干管的連接點(diǎn)上,要考慮干管的已定埋設(shè)深度是否允許旁側(cè)管接入六.繪制管道剖面圖選擇一條設(shè)計(jì)雨水主干管1-2-3-4-5-6-7-8設(shè)計(jì)管道底標(biāo)高、設(shè)計(jì)管道埋深、管長(zhǎng)、管徑及管道坡度標(biāo)入表內(nèi)。第四章雨水管網(wǎng)設(shè)計(jì)一、選定體制:由于城市沿河所以可使雨水就近排入水體,但考慮到初期雨水有一定污染且城西離給水廠近,所以考慮本設(shè)計(jì)采用完全分流制二、雨水管道定線盡可能利用自然地形坡度以最短的距離靠重力流排入附近的河流??衫玫铰愤厹吓懦晁?,在道路交叉口的匯水點(diǎn),低洼地段設(shè)雨水口,減少工程造價(jià)。一般不設(shè)雨水泵站。在沿河的城市中最好分別設(shè)干管直接排入。河道中不需設(shè)主干管,其余與污水管網(wǎng)規(guī)劃相同。三、設(shè)計(jì)參數(shù)1徑流系數(shù)=0.62重現(xiàn)期p=1a3折減系數(shù)m=24地面集水時(shí)間t=10min5查附錄3-2山西大同的暴雨強(qiáng)度公式:6.縣區(qū)土壤冰凍深度:0.8m四、設(shè)計(jì)流量與水力計(jì)算(1)劃分并計(jì)算各設(shè)計(jì)管段匯水面積首先量出地面標(biāo)高與管段長(zhǎng)度(選1-8如下表所示:地面標(biāo)高表(M)表2-4-1檢查井編號(hào)12345678地面標(biāo)高104.0103.9104.0104.2103.9103.5103.4103.5管道長(zhǎng)度表(M)表2-4-2管段編號(hào)1-22-33-44-55-66-77-8m)200235245260215220125匯水面積計(jì)算表表2-4-3設(shè)計(jì)管段編1-22-33-44-55-66-77-8號(hào)本段匯水面65,6657,5848,4938,3928,2918,1910,1積編號(hào)本段匯水面9.318.609.4210.5611.177.636.54積(ha)轉(zhuǎn)輸匯水面09.3117.9127.3337.8949.0656.69積(ha)總匯水面積9.3117.9127.3337.8949.0656.6963.23(ha)(2)進(jìn)行管道水力計(jì)算時(shí)的步驟:1.從圖上量各設(shè)計(jì)管段的長(zhǎng)度L2.將各個(gè)設(shè)計(jì)管段的設(shè)計(jì)流量列入表中第3入表中第10,11項(xiàng)目3.計(jì)算各個(gè)設(shè)計(jì)管段的地面坡度作為管道坡度的參考4.確定起始管段的管徑D,設(shè)計(jì)流速V,設(shè)計(jì)充滿(mǎn)度h/D和管道設(shè)計(jì)坡度5.確定其他管段的管徑D,設(shè)計(jì)流速V,設(shè)計(jì)充滿(mǎn)度h/D和管道設(shè)計(jì)坡度6.計(jì)算各管段上下端水面,管底標(biāo)高和管道埋設(shè)深度7.雨水干管水力計(jì)算見(jiàn)附表三五、雨水干管水力計(jì)算說(shuō)明1.表中第12,3,13,143-1,表3-2,表3-3取得其余各項(xiàng)經(jīng)計(jì)算后得到2.計(jì)算中假定管段的設(shè)計(jì)流量均從管段的起點(diǎn)進(jìn)入,即各管段的起點(diǎn)為設(shè)計(jì)斷面。因此個(gè)管段的設(shè)計(jì)流量是按該管段的起點(diǎn),即上游管段終點(diǎn)的設(shè)計(jì)降雨歷時(shí)(集水時(shí)間)進(jìn)行計(jì)算的:3.根據(jù)確定的設(shè)計(jì)參數(shù)、求單位面積徑流量q04.各個(gè)設(shè)計(jì)管段的單位面積徑流量q0乘以該管段的總匯水面積F得設(shè)計(jì)流量Q=q0·F5.求得設(shè)計(jì)流量Q后,即可進(jìn)行水力計(jì)算,求管段的管徑D,流速v,管道坡度I6.根據(jù)設(shè)計(jì)管段的設(shè)計(jì)流速求本管段的管內(nèi)雨水流行時(shí)間t2:7.管段長(zhǎng)度乘以管道坡度得到該管段起點(diǎn)與終點(diǎn)之間的高差,即降落量:H=I·L8.根據(jù)冰凍情況、雨水管道銜接要求及承受荷載的要求,確定管道起點(diǎn)的埋深或管底標(biāo)高。六、注意事項(xiàng):1.最小埋設(shè)深度1.2m,最大埋設(shè)深度6m2.最小流速0.75m/s3.若下游流量小于上游的按上流量為準(zhǔn)計(jì)算4.若上游有兩條干管,則計(jì)算下游流量用較大的∑t2第五章污水與泵站設(shè)計(jì)一、設(shè)計(jì)資料(1)基礎(chǔ)資料1、設(shè)計(jì)任務(wù)書(shū)2、地區(qū)氣象資料:該設(shè)計(jì)縣區(qū)在大同,土壤冰凍深度為0.8m3、地區(qū)水文與水文資料:該地區(qū)下水位為6m,污水處理廠沉沙池水位為110m4、泵站所在地附近地區(qū)一定比例的地形圖5、用水量水壓資料、水質(zhì)分析資料:本設(shè)計(jì)污水量為344.18L/s6、本設(shè)計(jì)泵站外275米處有一污水廠,標(biāo)高為95.5米7、管材及管道配件的產(chǎn)品規(guī)格(2)參考資料1、泵站形式運(yùn)行情況:本設(shè)計(jì)采用合建式矩形排水泵站,裝設(shè)立式水泵自罐式工作,三用一備用2、地區(qū)內(nèi)現(xiàn)有泵站設(shè)計(jì)圖,排水管網(wǎng)平面圖3、污水管道水力計(jì)算表和設(shè)計(jì)流量計(jì)算表等4、縣區(qū)平面圖,相關(guān)位置標(biāo)高5、其他資料二、水泵的選擇1、泵站設(shè)計(jì)流量計(jì)的確定根據(jù)排入管道的污水量為344.18L/s,取整為345L/s,可知最高日污水量超過(guò)15000m3<5000m3可設(shè)1~22、泵站的揚(yáng)程式中:Hss——吸水地形高度(mHsd——壓水地形高度(m∑hs、∑hd——污水通過(guò)吸水管路和壓水管路的水頭損失(包括沿程損失和局部損失)由于污水泵站一般揚(yáng)程較低,局部損失占總損失比重較大故不可忽略不計(jì)??紤]到污水泵在使用過(guò)程中因效率下降和管道中阻力增加而增加的能量損失,在確定水泵揚(yáng)程時(shí),可增大1~2m安全揚(yáng)程。因?yàn)楸迷谶\(yùn)行過(guò)程中集水池中水位是變化的,故所選水泵在此變化范圍內(nèi)應(yīng)處于高效率段。當(dāng)泵站的水泵超過(guò)兩臺(tái)時(shí),在選擇水泵時(shí)應(yīng)注意不但在并聯(lián)運(yùn)行時(shí),而且在單泵運(yùn)行時(shí)都應(yīng)在高效率段內(nèi),如下圖所示:圖2-5-1集水池中水位變化時(shí)水泵工況1-單泵特性曲線2-兩臺(tái)泵并聯(lián)特性曲線圖2-5-2水泵并聯(lián)及單獨(dú)運(yùn)行時(shí)工況三、確定集水池容積集水池的容積在滿(mǎn)足安裝格柵和吸水管的要求、保證水泵工作的水力條件以及能夠及時(shí)將流入的污水抽走的前提下,應(yīng)盡量小些。一般可采用不小于泵站中最大一臺(tái)水泵5min出水量的體積。四、機(jī)組與管道的布置特點(diǎn)1、機(jī)組與管道的布置特點(diǎn)污水泵站中機(jī)組臺(tái)數(shù)一般不超過(guò)4以常采用并列的布置形式。本設(shè)計(jì)布置形式如下:圖2-5-3污水泵站布置形勢(shì)圖2、管道的布置與設(shè)計(jì)特點(diǎn):(1)吸水管布置:①每臺(tái)水泵應(yīng)設(shè)置一條單獨(dú)的吸水管。②設(shè)計(jì)流速一般采用1.0~1.5m/s,最低不得小于0.7m/s,以免管內(nèi)產(chǎn)生沉淀。③吸水管進(jìn)口應(yīng)裝置喇叭口,其直徑為吸水管直徑的1.3~1.5倍。(1)壓水管布置:①壓水管的流速一般不小于1.5m/s水泵工作時(shí),其流速也不得小于0.7m/s,以免管內(nèi)產(chǎn)生沉淀。②若多個(gè)泵合用一條壓水管,壓水管直徑要變大。③壓水管高處設(shè)排氣閥,低處設(shè)進(jìn)水閥。④泵站內(nèi)管道敷設(shè)一般用明裝,采用鑄鐵管。五、泵站內(nèi)部標(biāo)高的確定泵站內(nèi)部標(biāo)高主要根據(jù)進(jìn)水管渠底部標(biāo)高或管中水位確定,自灌式泵站集水池底部與機(jī)器間底板標(biāo)高基本一致。集水池中最高水位,對(duì)于大、中型泵站即取進(jìn)水管計(jì)算水位標(biāo)高。集水池的有效水深,從最高水位到最低水位,一般取為1.5~2.0mi=0.1~0.2傾向集水坑。集水坑大小應(yīng)保證水泵有良好的吸水條件,吸水管喇叭口在集0.4m叭口進(jìn)口直徑的0.8倍。清理格柵工作平臺(tái)應(yīng)比最高水位高出0.5m以上。平臺(tái)寬度應(yīng)不小于0.8~1.0m。沿工作平臺(tái)邊緣應(yīng)有高1.0米的欄桿。六、污水泵站的輔助設(shè)備1、起重設(shè)備起重量在0.5t以?xún)?nèi)時(shí),設(shè)置移動(dòng)三腳架或手動(dòng)單梁吊車(chē),也可在集水池和機(jī)器間<0.5t0.5~2.0t時(shí),設(shè)置單軌吊車(chē)梁;起重量在2.5~5.0t時(shí),設(shè)置橋或行車(chē)。七、泵站工藝設(shè)計(jì)步驟和方法1、確定設(shè)計(jì)流量和揚(yáng)程的估算(1)縣區(qū)人口密度520人/ha,生活污水定額120L/cap·d。進(jìn)水管管底高程92.368m,管徑D=750mm,充滿(mǎn)度0.537出水管提升后水面高程為110m,經(jīng)60m管長(zhǎng)至處理構(gòu)筑物,地面高程95.5m。根據(jù)Q=344.18L/s,取整345,選擇集水池與機(jī)器間矩形泵站的四臺(tái)水泵(一臺(tái)6min的容量。有效水深取H=2m,集水池面積為(2)揚(yáng)程的估算:集水池最低水位與所需提升最高水位的高差=110-(92.368+0.75×0.537-2)=19.23m總出水線水頭損失根據(jù)Q=345L/sD=800mmv=0.68m/s,I=0.733‰設(shè)總出水管管中心埋深1.65m,局部損失為沿程損失的30%,泵站外管線(可取在50-100m)的水頭損失為[60+(110-95.5)+1.65]××(1+0.3)=0.073m假設(shè)泵站內(nèi)水頭損失1.5m,自由水頭1mH=19.23+0.073+1.5+1=21.80m2、初步選泵和電動(dòng)機(jī)查手冊(cè)11,選用8PW型離心污水泵,每臺(tái)Q=115L/s,H=25米;配選電機(jī)Y315S-6,n=980r/min,N=75KW3、設(shè)計(jì)機(jī)組基礎(chǔ)(1)機(jī)組基礎(chǔ)的計(jì)算基礎(chǔ)長(zhǎng)度L=底座長(zhǎng)度L1+(0.15~0.20)=1.295+0.15=1.445m基礎(chǔ)寬度B=底座螺孔間距(在寬度方向上)b1+(0.15~0.2)=0.7+0.15=0.85m基礎(chǔ)深度(W=Wp+Wm=750kg=7350N對(duì)混凝土基礎(chǔ),=23520N/m3;)(2)機(jī)器間長(zhǎng)度La—機(jī)組基礎(chǔ)長(zhǎng)度b—機(jī)組基礎(chǔ)距離c—機(jī)組基礎(chǔ)與墻的距離泵房總長(zhǎng)度L=4a+3b+2c=4×1.445+3×1.3+2×1.5=12.68m(3)機(jī)器間寬度B在圖中按要求進(jìn)水側(cè)水泵基礎(chǔ)與墻壁凈距離D1應(yīng)不小于1m,出水側(cè)水泵基礎(chǔ)與墻壁靜距離B1不小于3m,L1為機(jī)組基礎(chǔ)寬度??倢挾菳=D1+B1+L1=1+3+0.955=4.955m圖2-5-5機(jī)器間寬度示意圖4、計(jì)算水泵吸水管、壓水管直徑根據(jù)污水泵站吸水管與壓水管流速的要求選吸水管和壓水管的管徑,通常,泵房?jī)?nèi)吸水管用鋼管,泵房外壓水管用鑄鐵管,可查手冊(cè)1的對(duì)應(yīng)表。5、布置機(jī)組和管道詳細(xì)布置圖見(jiàn)泵房平面圖與泵房剖面圖6、泵房經(jīng)平面布置后,對(duì)水泵總揚(yáng)程進(jìn)行核算選擇最不利管段1-2-3-4-5-6如下(注:泵房?jī)?nèi)用鋼管,泵房外采用鑄鐵管)圖2-5-6水泵布置剖面圖圖2-5-7水泵布置平面圖①吸水管路1-2吸水管路(鋼管):Q=115L/s,Dg=350mm,v=1.195m/s,I=6.01‰,根據(jù)圖示直管部分長(zhǎng)度3.2m喇叭口1個(gè):ζ=0.1Dg350mm90°彎頭2個(gè):ζ=0.89閘閥(1/8開(kāi)啟度)1個(gè):ζ=0.15Dg350×Dg250偏心漸縮管1個(gè):由大到小ζ=0.18局部損失沿程損失總吸水管路損失=0.208+0.0195=0.228m②壓水管路2-3-4-5-6第一段2-3:壓水管(鋼管):Q=115L/s,Dg=300mm,V=1.625m/s,I=13.6‰,根據(jù)圖示直管部分長(zhǎng)度4.0mDg200×Dg300漸擴(kuò)管1個(gè):ζ=0.16Dg300mm止回閥1個(gè):ζ=3.5閘閥(1/8開(kāi)啟度)1個(gè):ζ=0.15Dg300mm90°彎頭2個(gè):ζ=0.50局部損失沿程損失第二段3-4:壓水管(鑄鐵管):Q=115L/s,Dg=400mm,V=0.92m/s,I=3.07‰,直管部分長(zhǎng)度2.2m丁字管1個(gè):ζ=1.5局部損失沿程損失第三段4-5:壓水管(鑄鐵管):Q=230L/s,Dg=400mm,V=1.83m/s,I=17.8‰,直管部分長(zhǎng)度1.0m閘閥(1/8開(kāi)啟度)1個(gè):ζ=0.15丁字管1個(gè):ζ=0.1局部損失沿程損失第四段5-6:壓水管(鑄鐵管):Q=345L/s,Dg=500mm,v=1.76m/s,I=8.13‰,直管部分長(zhǎng)度1.5m沿程損失出水管總水頭損失=0.073+0.8075+0.0542+0.064+0.0068+0.0427+0.0118+0.012=1.1782m水泵總揚(yáng)程H=19.23+0.227+1.1782+1=21.3782m說(shuō)明選用8PW型水泵是合適的7、確定泵房建筑高度(采用的是地下式泵房)圖2-5-8泵房建筑高度示意圖H=a+b+c+d+e+f+gH—泵房高度a—單軌吊車(chē)梁高度(0.2m)b—滑車(chē)高度(0.5m)c—起重葫蘆在鋼絲繩緊繃狀態(tài)長(zhǎng)度(2.5~3.0m)d—起重繩垂直長(zhǎng)度(水泵0.85Xm;電機(jī)1.2Xm,X—起重件寬度)e—最大一臺(tái)水泵或電動(dòng)機(jī)高度f(wàn)—吊起物底部和最高一臺(tái)機(jī)組頂部的距離g—最高一臺(tái)水泵或電動(dòng)機(jī)頂至室內(nèi)地坪高度計(jì)算時(shí):a=0.2mb=0.5mc=2.5md=0.80me=0.955mf=0.5mg=0.955+0.2=1.155mH1=a+b+c+d+e=0.2+0.5+2.5+0.80+0.955=4.955m泵房地下部分H2=f+g=1.655m總高度H=H1+H2=4.955+1.655=6.61m污水干管設(shè)計(jì)流量計(jì)算表附表2-1居住區(qū)生活污水流量Q(L/s)集中流量管段街街區(qū)編號(hào)區(qū)面積編F(ha號(hào))本段流量轉(zhuǎn)輸流量比流量q0L/(s·h(L/S)a))合計(jì)平均流量(L/s)總變化系數(shù)Kz生活污水設(shè)計(jì)流量Q1(L/s)本段(L/s)轉(zhuǎn)輸(L/s)設(shè)計(jì)流量(L/s)123456789101112131-213.839.9859.9852.1020.93120.9312-327.3319.73219.7321.9438.37738.3773-441.129.67429.6741.8655.18055.180

4-554.4939.34239.3421.8070.92270.922

5-668.1449.19749.1971.7686.53586.535

6-782.3659.46459.4641.72102.435102.435

7-895.6469.05269.0521.69117.012117.012

8-9109.7579.24079.2401.67132.258132.258

9-10109.7579.24079.2401.67132.258132.258

10-11562.90.7222.094109.7579.24081.3331.66135.364135.364

11-12474.110.7222.967112.6581.33384.3011.66139.751139.751

24-2515.1410.93110.9312.0822.68722.687

25-2625.7318.57718.5771.9636.37136.371

26-2737.2326.88026.8801.8850.53150.531

27-2847.7134.44734.4471.8363.01263.012

28-2955.1139.78939.7891.8071.64071.640

29-3062.2444.93744.9371.7879.83379.833

30-3169.3650.07850.0781.7687.91287.912

31-3280.0557.79657.7961.7399.87499.874

32-1290.9365.65165.6511.70111.869111.869

12-13373.90.7222.816207.69149.952152.7681.55237.221237.221

13-14272.740.7221.978211.59152.768154.7461.55239.953239.953

16-1710.177.3437.3432.1715.92115.921

17-1822.7916.45416.4541.9832.64832.648

18-1935.7125.78325.7831.8948.69148.691

19-2046.2333.37833.3781.8461.269

溫馨提示

  • 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶(hù)所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶(hù)上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶(hù)上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶(hù)因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。

評(píng)論

0/150

提交評(píng)論