(能源化工行業(yè))化工廠常用PSSR檢查表國外PSSRChecklistExampleA-1PSSR清單示例A-1DescriptionofSystem/AreaUnderReviewDateTime所審查系統(tǒng)/區(qū)域的描述日期時間ListofParticipantsCirculation:thosepresentplus…參與者名單傳閱:參加人員加上Comments討論ItemRecommendationDepartment/CompletedResponsibleNo.(TypeActionBelowor‘notDateapplicable’)Person序號完成日期建議(請?zhí)顚懴铝行袆禹椈蜃⒚鳌安贿m部門/責(zé)任人用”)1.ReviewHAZOPlistforapplicableactions查看HAZOP列表看相關(guān)行動項是否解決2.ReviewCHAZOPlistforapplicableactions查看CHAZOP列表看相關(guān)行動項是否解決3.Reviewpunchlistforapplicableactions.查看剩余工作清單看相關(guān)行動項是否解決4.Noiselevelmonitoring(document)噪音等級監(jiān)測(文件)5.Exposuremonitoring(document)操作人員暴露風(fēng)險監(jiān)測(文件)6.Emissionspermits排放許可7.Otheroperatingpermits其他允許的行動SystemCheckoutItems系統(tǒng)檢查項目ItemRecommendationDepartment/CompletedResponsibleNo.(TypeActionBelowor‘notDateapplicable’)Person序號完成日期建議(請?zhí)顚懴铝行袆禹椈蜃⒚鳌安贿m部門/責(zé)任人用”)8.Complete/documentqualityassuranceprogram:完成質(zhì)量保證體系并建立了文檔a)Receivedequipment=purchased收到的設(shè)備=購買的設(shè)備b)Adherencetodesigndrawings/specifications采用的設(shè)計規(guī)范c)Materialsofconstruction施工材料d)Workmanship工藝技術(shù).Equipmentcomponentscheckout/commissioning(document)設(shè)備部件檢查/調(diào)試(文件)9.Loopandinterlock/permissive/alarm:setpointadjustmentandtesting(documentresults)回路和聯(lián)鎖/許可/報警:設(shè)置點調(diào)整和測試(文檔記錄)10.Instrumentcalibrationsdoneanddocumented儀表校訂完成并記錄11.Validationprotocoldeveloped,approvedandexecuted制定、批準和執(zhí)行的驗證協(xié)議12.Pressuretestingdoneanddocumented壓力測試完成并記錄13.Systemcleanedandflushed系統(tǒng)已完成清掃、沖洗14.Fireprotectionssystemsinspected,acceptance-testeddocumentationprovided消防系統(tǒng)已檢查,并有測試、驗收記錄15.Ventilationsystemsbalanced通風(fēng)系統(tǒng)已平衡16.Performancecheckoutoflocalexhaustsystems局部排氣系統(tǒng)的性能檢測ItemRecommendationDepartment/CompletedResponsibleNo.(TypeActionBelowor‘notDateapplicable’)Person序號完成日期建議(請?zhí)顚懴铝行袆禹椈蜃⒚鳌安贿m部門/責(zé)任人用”)17.Vibrationmeasurements/documentation振動測量記錄18.Fieldradiographydoneanddocumentedasrequired現(xiàn)場放射性物質(zhì)檢測已完成并記錄19.Baselinedata,suchasthicknessreadingsforpressurevessels/piping基礎(chǔ)數(shù)據(jù),如壓力容器/管線的壁厚20.Otherbaselinedata其他基礎(chǔ)數(shù)據(jù)21.NDTreports無損檢測報告22.Waterbatching(document)配水(記錄)EngineeringDesignDocumentation工程設(shè)計資料23.Narrativeofcontrolphilosophy/Sequenceofoperationsdocumentation操作控制原理/操作順序的說明資料24.Instrumentindex儀表索引25.Instrumentloopdiagrams儀表回路圖26.Interlock(safety&non-safety)descriptions聯(lián)鎖(安全和非安全)描述27.As-builtdrawings:P&IDs,electrical,piping,mechanical竣工圖:P&ID圖,電氣圖,配管圖,機械圖28.Tabulationofprocessalarms,interlocks/permissivedescriptionsandtripswithsettings(P&ID)工藝報警表、聯(lián)鎖/許可說明表和帶設(shè)定值(P&ID)的跳轉(zhuǎn)表29.Reviewandapprovaloffireprotectionssystemsdesign消防系統(tǒng)設(shè)計的審查和許可ItemRecommendationDepartment/CompletedResponsibleNo.(TypeActionBelowor‘notDateapplicable’)Person序號完成日期建議(請?zhí)顚懴铝行袆禹椈蜃⒚鳌安贿m部門/責(zé)任人用”)30.Pipingspecifications(P&I/mechanicaldrawings)配管圖(P&I圖/機械圖)31.Pressurereliefdevicesizingcalculations安全閥規(guī)格的選定計算32.ASMEcodepressurevesselsU-1datasheets(toMaintenance)壓力容器ASME代碼U-1數(shù)據(jù)表(用于維修)33.Referencecodes/standardsforfacilitydesign裝置設(shè)計的參考規(guī)范/標準34.Referencecodes/standardsforfacilityinstallation設(shè)備安裝的參考規(guī)范/標準35.Designcodesforspecificequipment特殊設(shè)備的設(shè)計規(guī)范36.Weldercertification焊工資格證書37.NDTcertification無損檢測證書38.Electricalclassificationdrawings電器分類圖39.Electriciancertificationforclassifiedareas特定施工區(qū)域的電工資格證書MaintenanceItems維修項目40.SparepartslistsdevelopedListequipment:備品備件清單并附設(shè)備清單41.Stockrequiredspareparts備品備件所需儲存設(shè)施42.Equipmentmanuals/specificationstoMaintenanceandOperatingDepartment維修和操作部門的設(shè)備手冊/說明43.Vendorprints供應(yīng)商提供的印刷資料ItemRecommendationDepartment/CompletedResponsibleNo.(TypeActionBelowor‘notDateapplicable’)Person序號完成日期建議(請?zhí)顚懴铝行袆禹椈蜃⒚鳌安贿m部門/責(zé)任人用”)44.Submitpreventivemaintenancerequests(PM’s)提交的預(yù)防性維修要求45.Servicecontractsinplace服務(wù)合同已簽訂46.Trainmaintenancepersonnelanddocument培訓(xùn)維修人員和相關(guān)培訓(xùn)資料OperationalItems生產(chǎn)項目47.DevelopSOPandspecialprocedures–incorporatesafetyandoperationalissues:編寫標準操作規(guī)程(SOP)及特殊操作規(guī)程——考慮了操作風(fēng)險和可操作性問題48.Completechangecontrolauthorizations完成變更控制授權(quán)49.Develop/issueoperatingprocedures:制定/頒布下列操作規(guī)程a)Initialstart-up初次開車b)Normalstart-up正常開車c)Normaloperation正常操作d)Normalshutdown正常停車e)Emergencyoperationsincludingemergencyshutdown包括緊急停車的應(yīng)急操作f)Start-upfollowingemergencyshutdown緊急停車后開車g)Start-upfollowingturnaround大修后開車h)Non-routineprocedures(equipmentclean-out,equipmentpreparationformaintenance)非常規(guī)程序(設(shè)備清理、設(shè)備維修準備)ItemRecommendationDepartment/CompletedResponsibleNo.(TypeActionBelowor‘notDateapplicable’)Person序號完成日期建議(請?zhí)顚懴铝行袆禹椈蜃⒚鳌安贿m部門/責(zé)任人用”)i)Auxiliaryequipmentoperation輔助設(shè)備的操作50.Trainoperatingpersonnelanddocument培訓(xùn)操作人員和相關(guān)培訓(xùn)資料51.Providetechnicalcoverage技術(shù)服務(wù)范圍52.Whatistheprobabilityofcontainmentfailure?Whatarethesubsequentconsequences?Reviewspillcontainment,rainwaterrunoff,andfirewatercontainment.防泄漏設(shè)施的失效概率是多少?失效的后果是什么?審查防泄漏設(shè)施、雨水流量和消防水容量ElectricalIssues電氣問題53.Panelaccess,clearancearoundpanel,keys,etc.配電盤的通道、配電盤周圍的間隙、鑰匙等54.Cableentrysection–glanding,housekeepingandotherissues電纜接入部分—密封、保潔及其他問題55.Panelpowersourceidentified?Multiplefeeds?配電盤電源的標識?多源供電?56.Spaceheatersrequired?需要空間加熱器嗎?57.Lightinginpanels配電盤里的照明58.Canopiesetc.foroutdoorpanels用于室外配電盤的雨棚等59.Protectionsettingsavailable?有保護設(shè)置嗎?60.Panelboardschedules配電盤面板清單61.Sparecapacityavailable?有備用容量嗎?62.PPEavailable?HVmats,gloves有個人防護用品嗎?有高壓絕緣墊嗎?有高壓絕緣手套嗎?ItemRecommendationDepartment/CompletedResponsibleNo.(TypeActionBelowor‘notDateapplicable’)Person序號完成日期建議(請?zhí)顚懴铝行袆禹椈蜃⒚鳌安贿m部門/責(zé)任人用”)63.Emergency/Standbypowerrequired?有應(yīng)急/備用電源嗎?64.VSDsettingsavailable–factory/commissioning變頻器設(shè)置—工廠/調(diào)試65.Roomaccess,permitting,maintainability,ingress/egressofequipment房間通道、許可證、可維修性、設(shè)備的進出通道66.Pocketsfordrawingsinpanels?配電盤的圖紙集67.Voltagewarninglabels?電壓警告標簽68.Ventilationsufficient?通風(fēng)充足嗎?69.Suitabilityforarea-IPrating,GMPsuitability,hazardousareaclassification.區(qū)域適宜性——國際防護等級、GMP適宜性、危險區(qū)域分類-ReliefDevices-泄放設(shè)備70.AretherestandardmarkingsontheP&ID?在P&ID圖上有標準代號嗎?71.Dorelieflinesventtoasafelocation?放空線排放到一個安全地點嗎?72.Arerelieflinesandreliefdevicessecuredandadequatelysized?放空線和泄放設(shè)備安全嗎?尺寸足夠大嗎?73.Arethereanyisolationvalveswhichwillinhibitoperationofreliefvalvesifclosed?IfYES,nominateOperationstomonitor.IfNO,recordno.有處于關(guān)閉狀態(tài)會抑制放空閥操作的隔離閥嗎?如果有,請指定操作人員對其進行監(jiān)視。如果沒有,記錄無ItemRecommendationDepartment/CompletedResponsibleNo.(TypeActionBelowor‘notDateapplicable’)Person序號完成日期建議(請?zhí)顚懴铝行袆禹椈蜃⒚鳌安贿m部門/責(zé)任人用”)74.Isthereastandardoperatingprocedureforreliefdevicesinplace?現(xiàn)場有泄放設(shè)備的標準操作規(guī)程嗎?-ForFieldVerification-現(xiàn)場確認75.Islightingsufficient?照明充足嗎?76.Isemergencylightingsufficient?應(yīng)急照明充足嗎?77.Aresteampipes,valves,ortrapssituatedwithinproximityofpeopleinsulated?位于人接近范圍內(nèi)的蒸汽管線、閥門或疏水器被隔離了嗎?78.Isallinstrumentationidentifiedandtagged?所有的儀表都有標識和掛牌了嗎?79.Isthereanyrustedordamagedequipment?有任何生銹或損壞的設(shè)備嗎?80.Areswinggatesinstalledontopofladdersoronaccessplatforms?在梯子頂部或平臺通道上安裝了止回門嗎?81.Reviewedgeprotectiononplatformsandheights.Willitprotectpersonnelandequipment?Isaccessadequate?檢查平臺和高處的邊緣保護。它能保護人員和設(shè)備嗎?通道足夠嗎?82.Dosafetyshowersprovideahazardtopeople(slips),product(contaminationofsystems),oringresstoelectricalswitchgearorequipment?安全噴淋對人(滑跤的危險)、產(chǎn)品(系統(tǒng)的污染)或內(nèi)部的電氣開關(guān)柜或設(shè)備產(chǎn)生危險了嗎?83.Aresafetyshowerssuppliedfromtemperedwater?安全淋浴供應(yīng)熱水嗎?84.Ischemicaldosingwithinasafeproximityofpeopleandproduct?化學(xué)品操作是在人和產(chǎn)品安全接近范圍內(nèi)嗎?ItemRecommendationDepartment/CompletedResponsibleNo.(TypeActionBelowor‘notDateapplicable’)Person序號完成日期建議(請?zhí)顚懴铝行袆禹椈蜃⒚鳌安贿m部門/責(zé)任人用”)85.Labelallpipelines標識所有的管線86.Labelallelectricswitches,disconnects,MCCs,controlpanels,cables,etc.標記所有的電氣開關(guān)、中斷器、電動機控制器、控制盤和電纜87.Labelvessels(material,hazardwarnings)List:標記容器(材料、危險警告)的清單88.Sealwallpenetrations密封墻壁的滲透89.Pourconduitseals灌注導(dǎo)管的密封90.Installfireextinguishers91.Evacuationroutesposted92.Installappropriateareasigns93.Isallscaffoldingandequipmentremoved;isgeneralhousekeepingacceptable?94.Ifthereispotentialforentrapmentorexposure,hasanE-Stopbeenprovided?95.Iffullguardingisinplace,hasalockableisolationdevicebeenprovided?96.Pestcontrolrequiredinroom/building?97.MSDSsheetsrequired?98.Sprinklersinrooms?99.Singlepointoffailurecondition?Hasitbeenidentified?–Record.PSSRChecklistExampleA-2Pre-startupSafetyReviewChecklistInspectionDate:Department/Area:ProjectNumber:Title/Equipment:Signaturesbelowindicateacceptancethattheequipmentorprojectissafeandsatisfactorytostart-upwiththeexceptionsnoted.Engineering/MaintenanceDateEHSGroupDateQAGroupDateManufacturing/OperationsDateProjectEngineerDateProcessEngineeringDateDetails(referencecategory/itemResponsibilityComplete
Checklistno.)Sign&ItemNo.DateCategoryAActionItems-ItemstobecompletedBEFOREauthorizationandstart-up.5.CategoryBActionItems-ItemstobecompletedAFTERstart-up..2.Signbelowonlywhenallpunchlist“beforestart-up”itemsarecompletedAuthorized:Facility/EquipmentOwnerSignature:DatePSSRITEMCATEGORY/ITEMTOASSESSNotNO.Applicable1.1GENERALSAFETY1.1.1HaveALLappropriatepersonnel(Operations,Maintenance,Technical,andSupervision)receivedadequateandappropriatetrainingontheequipmentandoperatingprocedures?1.1.2HasadequateandappropriatePPE(PersonalProtectiveEquipment)beenspecifiedintheWorkProceduresand/orStandardOperatingProcedures.HasthePPEbeenprovided?HavethePPEusersbeentrainedintheuseofthePPE?Isthetrainingdocumented?1.1.3Havemeasuresbeentakentoadequatelyguardalldangerouspartsofthisequipment?1.1.4Hassufficientprovisionbeenmadefortheelectricaland/ormechanicalisolationoftheequipment?1.1.5Arepointsofisolationclearlymarked/labeledandreadilyaccessible?1.1.6Havebump/triphazardsbeenproperlyidentifiedandadequatelymarked?Haveallsharpedgesbeenremoved?1.1.7Hasproperguarding,handrails/barriers,beenprovidedtopreventfalls?1.1.8Haveallhot/coldsurfacesbeenadequatelyguardedtopreventburns?Areallcoldsurfacesadequatelyinsulatedtopreventcondensationdrips(sliphazards)?1.1.9AreSafetyShowersandEyeWashfacilitiesprovidedandadequatelymarked?AretheSafetyShowersandEyeWashfacilitiesroutinelyinspected?DotheSafetyShowersandEyeWashfacilitieslocationscomplywithCorporateguidelines?AretheSafetyShowersandEyeWashfacilitiesreadilyvisibleandaccessible?1.1.10Hassufficientlightingbeenprovidedsothatoperation,servicing,maintenance,andrepairofthefacilitiescanbecarriedoutsafely?1.1.11Arenotices,dials,screens,etc.forprovidingoperationalinstructions,safetywarnings,andemergencyinformationprovided,ifrequired,andpositionedsothattheyareclearlyvisibleandeasilyread?PSSRITEMCATEGORY/ITEMTOASSESSNotNO.Applicable1.1.12Havealloverheadfixtures,forexample,pipe-hangers,pipesleeves,pipesleevecovers,valvehandles,flooropeningcovers,etc.,whichcouldfallorbedislodged,beenproperlysecured?1.1.13ArealloftheapplicableWorkPermitProcedures(ConfinedSpaceEntry,LockOut/TagOut,HotWork,HighWork,etc.)inplace?HavetheOperating,Maintenance,andSupervisorypersonnelbeenproperlytrainedontheWorkPermitProcedures?1.1.14Hasthefireprotectionsystemsbeeninspectedbytheinsurancecompany?Hasacceptancetestingbeencompletedanddocumented?Isthereanagreedontestandinspectionprogramforthefireprotectionsystems(includingalarmsystems)?1.2MACHINERY/EQUIPMENTSAFETY1.2.1Hasthemachinery/equipmentbeeninstalledsothatitwillbestableandsecureduringoperation?1.2.2Hasallaccesstodangerousmovingparts,ordangerzonescreatedbytheequipment,beenpreventedbytheprovisionofthecorrectguards,interlocks(bothsafety&non-safety)and/orbarriers?1.2.3Havethecorrectsafetymeasuresbeentakentopreventanyriskfromhot/coldsurfaces,ejectionofmaterial,failureofpartsandtheirejection,overheating/fire?1.2.4Hassafeaccessbeenprovidedtotheequipmentthatrequiresoperatorandcalibrationandmaintenancepersonnelaccessfornormaloperations,adjustments,service,calibration,maintenance,orrepair?Haveslip,trip,trap,crush,entanglement,fall,bump,andcuthazardsbeenminimized?1.2.5IstheequipmentprovidedwiththeproperlyidentifiedSTART/STOPandEMERGENCYcontrolsthatarepositionedforsafeoperationwithouthesitation,orlossoftime,andwithoutambiguity?1.2.6IstheequipmentprovidedwithaclearlyidentifiedmeanstosecurelyisolateitfromALLenergysources?1.3ERGONOMICS1.3.1Havetheworkstations,workplace,orequipmentbeenconstructedsothatneedforstooping,bendingstretching,over-reachingandworkingover-headduringoperationhasbeeneliminatedorminimized?1.3.2Hastheneedtolift,carry,pushorpullheavyloads,orparts,beeneliminatedtotheextentpossible?PSSRITEMCATEGORY/ITEMTOASSESSNotNO.Applicable1.3.3Arealldisplayscreens,dialsandSTART/STOP/EMERGENCYbuttonspositionedsothattheyarereadilyvisibleandaccessiblebytheoperatingpersonnel?1.3.4HaveVisualDisplayScreensbeenpositionedsothatinterferencefromglareisreducedtotheminimum?1.3.5Haveworkstationsbeendesignedandequippedsothattheoperatorcanadoptacomfortableposition?(Thatis,abletostand,orchangepositionandsitupright,angleatelbowsandknees90,feetonfloor.)1.3.6DoestheoperationofthisequipmentincreasetheriskofUpperLimbDisorder;forexample,repetitivetasks,handlingoperations,machinepacedworkandprolongedoperation?1.4OCCUPATIONALHEALTH1.4.1Haveallhealthrisksarisingfromthegases,liquids,dusts,mists,biologicalhazardsorvaporsusedby,containedinoremittedbythisequipmentbeenassessed?Havethehealthrisksbeeneliminatedorareadequateengineeringcontrolsutilizedtominimizetherisks?1.4.2HasadequateRPE(RespiratoryProtectiveEquipment)beenspecifiedintheOperatingProcedures?1.4.3HastheneedforanOccupationalHealthMonitoringProgrammebeenassessed?HasaMonitoringProgrammebeenscheduled?1.4.4HavetheOperatingProceduresbeenreviewedtotakeintoaccountanyadditional“healthhazards”whichmayarisefromoperationormaintenanceofthisequipment?1.4.5HasadequateLEV(LocalExhaustVentilation)beeninstalled,tested,balanced,andenteredonanInspectionSchedule?1.4.6Haveadequateinspection/cleaningportsbeenprovidedonductwork?1.4.7Arerelieffacilitiesdirectedtoasafeplaceawayfromtheworkplace?1.4.8HasaNoiseSurveybeenconsideredandaNoiseCompliancePlanprepared,ifrequired?1.4.9Hasallinsulationbeenidentified?1.4.10Hasallpipework,tanks,andequipmentcontaininghazardousmaterialsbeenadequatelylabeled?2.0PROCESSSAFETY2.1PROCESSTECHNOLOGY2.1.1Areup-to-dateMaterialSafetyDataSheetsavailable?PSSRITEMCATEGORY/ITEMTOASSESSNotNO.Applicable2.1.2Havethehazardouseffectsofinadvertentmixingofdifferentmaterialsbeenconsidered(thatis,hasachemicalinteractionmatrixbeenprepared/updated)?2.1.3Hastheprocessdesignbasisbeendocumentedorupdated?Hasthecontrolphilosophyandsequenceofoperationsbeendocumented?2.1.4Hastheequipmentdesignbasis(forexample,BPF’s/P&IDs)beendocumented/updated?2.1.5Havetherecommendationsfromsafetyreviews,ProcessHazardsAnalysis(PHA),HazardsandOperabilityReviews(HAZOP),CHAZOP,orothers,beenimplemented?Recordanyincompleteitems.2.1.6AreallreliefdevicesshownontheP&IDs?Arestandardmarkingsusedonthereliefdevices?Aretherelief/rupturepressuresincludedontheP&IDs?2.1.7Havethepressurereliefdevicecalculationsbeenprovided?WasDIERStechnologyutilizedtosizethepressurereliefdevicesforallpressurevessels?Doesthesizingofpressurereliefdevicesagreedwiththecalculatedsizes?Dothecalculationstakeintothedownstreampiping?2.1.8Dothereliefdevicesventtosafelocations?Iscontainmentprovidedforliquidsandsolidsreleasedfrompressurereliefdevices?2.1.9Arethereisolationvalvesthat,ifclosed,willinhibittheoperationofpressurereliefdevices?Ifyes,Operationsmustestablishcontrolplanstoinsurethattheisolationvalvescannotinhibittheoperationofthepressurereliefdevices.2.1.10AreallpressurereliefdevicesincludedinthePreventiveMaintenanceProgram?Aretheinspectionandtestingofreliefdevicesinaccordancewithlocalregulations?2.2MANAGEMENTOFCHANGE–TECHNOLOGY/MANAGEMENTOFSUBTLECHANGE2.2.1Hasamanagementofchange–technology/subtlechangedocument(forexample,ChangeofDesign-COD)beenapproved?2.2.2Hasatestauthorizationbeenapproved?2.2.3Areallactionitems,arisingfromtheCOD,thatweredeemednecessaryforstart-up,complete?PSSRITEMCATEGORY/ITEMTOASSESSNotNO.Applicable2.2.4Haveallchangesmadeduringconstructionbeenrecordedandauthorized?Havehazardsevaluations(PHAs,HAZOP,orCHAZOP)beendoneonallthechangesmadeduringconstruction?2.3PROCESSHAZARDSANALYSIS2.3.1HaveprojectPHAsbeenapprovedandafinalprojectsafetyreportbeenprepared?2.3.2Areallactionitems,deemednecessarybythePHAteamforstart-up,complete?2.3.3Hastheprojectbeenapprovedas“Safetoproceedwith”bythePHAteam?2.4QUALITYASSURANCE2.4.1Havechecksandinspectionsbeenmadetoensurethatcriticalequipmentisinstalledproperlyandisconsistentwithdesignspecificationsandvendor’srecommendations(forexample,alarmandinterlock(safety&non-safety)tests;equipmentalignmentandservicetoprocessinter-connections)?2.4.2Havequalityassuranceinspectionreports,coveringfabrication,assembly,andinstallation,beencompletedinaccordancewiththeproject’squalityassuranceplanandreportsfiledwiththeequipmentanddesignbasisdocumentation?2.4.3ListspecificitemsfieldcheckedaspartofthisPre-Start-upSafetyReviewtoensurethat:Theconstructionmeetsthedesignspecifications.Theconstructionmatchesthedrawings.2.4.4Havethefollowingdocumentedbeenprovidedandapproved:Instrumentindexesandinstrumentloopdiagrams?Atabulation,includingsettings,ofinterlocks(bothsafety&non-safety)andtrips(hardwireandsoftware),processalarmsandpermissivedescriptions?As-builtdrawingscoveringP&IDs,electrical,piping,andmechanical?DatasheetsforpressureequipmentbuilttoASMEorequivalentcodes?Weldercertification?Non-destructivetest(NDT)certifications?Electricalcertificationforclassifiedareas?2.5MECHANICALINTEGRITY2.5.1Havemaintenanceproceduresbeenapproved?2.5.2Havemaintenancepersonnelbeentrained?PSSRITEMCATEGORY/ITEMTOASSESSNotNO.Applicable2.5.3Havesparepartslistedbeendevelopedandenteredintothepartsorderingsoftwareprogram?Arethereadequateinventoriesofspareparts,operatingsuppliesandmaintenancematerials?2.5.3Havequalitycontrolproceduresbeenapprovedformaintenancematerialsandspareparts?2.5.4Haveinspectionsandtests,includingregulatoryrequirements)forthefollowingequipmentbeenincludedinamaintenanceschedule?Pressurevesselsandstoragetanks?Pressurereliefsystems,ventsystems,anddevices?Criticalcontrols,interlocks(bothsafety&non-safety),alarmsandinstruments?Emergencydevices(includingshutdownsystemsandisolationsystems)?Fireprotectionequipment?Pipingsystems(incl.Components,forexample,valves,excessflowvalves,expansionbellows)incriticalservice?Keyprocess-to-servicetie-ins?Electricalearthening,grounding,bonding?MCCstarters?Emergencyalarmandcommunicationsystem?Monitoringdevicesandsensors?Pumps?Liftingequipment?2.5.5Hasareliabilityengineeringanalysisbeenconsidered/completedforPSMcriticalequipment?2.5.6Istheequipmentinspectedbyanyoutsidebodyandcertificatesonfile(forexample,CEmarking,liftingequipmenttestcertificates,pressuresystemsregulations,andotheritems)?2.5.7Haveallcommissioningtestsorinspectionsbeenidentified(forexample,pressure,orleaktests,passivatingprocedures)?2.6OPERATINGPROCEDURESANDSAFEWORKPRACTICES2.6.1Havestandardoperatingproceduresbeenprepared/updatedandapproved?Dotheoperatingprocedurescover:PSSRITEMCATEGORY/ITEMTOASSESSNotNO.ApplicableInitialstart-up?Normalstart-up?Normaloperations?Normalshutdowns?Emergencyoperationsincludingemergencyshutdowns?Start-upafteremergencyshutdowns?Start-upfollowingturnarounds/prolongedshutdowns?Non-routineproceduresuchasequipmentclean-outsandpreparationofequipmentformaintenance?Auxiliaryequipmentoperationsincludingasexamples;LEVandVentilationSystems,Heat/CoolSkids,Water(Soft,RO,WFI,Tower,etc.)Systems,InstrumentandProcessAirSystems,WasteTreatmentSystems,Cooling(GlycolRefrigeration)Systems,SteamGeneration,andothers?Safetyandoperationalissues?Changecontrolprocedures?2.7TRAININGANDPERFORMANCE2.7.1Hasspecificprocess(orjobtask)trainingbeengiventopersonnel?2.7.2.Havetrainingrecordsbeenupdated?2.8CONTRACTORSAFETY2.8.1.Haveallcontractpersonnelbeenadequatelytrainedinappropriate:chemicalawareness,maintenance,andoperatingactivitiesandevacuationprocedures?2.9INTERLOCKSANDALARMS2.9.1Hasthealarm/interlock(safety&non-safety)beenclassifiedanddesignedbytheProjectTeam?DidtheProjectTeamincludemembersofthePHAteam?2.9.2Didthelooptestingconfirmthatthealarm/interlock(safety&non-safety)actionproved,underallconceivablefailureconditions,tobefail-safe?2.9.3.PriortothisPSSR,hasaninterlock/criticalalarmStandardOperatingProcedurefortesting,throughtothefinalelement,beenpreparedandreviewed/authorizedbyacompetentpersonforeachneworupgradedcontrolsystem?2.9.4.Foralarms/interlocks(bothsafety&non-safety)withmorethanonesoftwareorhardwarecircuit,haveallpossibleinterlockroutesbeentested?2.9.5Hasallappropriateprocesstechnologybeenupdated(forexample,interlocklists,P&IDs,logicdrawings,etc.)?2.9.6DoesyourControlSystemdocumentationadequatelyspecify:PSSRITEMCATEGORY/ITEMTOASSESSNotNO.ApplicableAllmajorcomponentsandtheirmodelandserialnumbers?Allcommunicationcableslayoutandconfiguration?Anyconfigurableorcustomsettingsandset-up?2.9.7Hasconsiderationbeengiventosuitablefiredetectionandpreventionsystemsfortheequipment?2.9.8Doyouhaveanappropriateproceduretoensurethatyoursoftwareisprotected(forexample,routinelyarchived,key/passwordprotected,etc.)?2.9.9Hasthesoftwarebeenproperlydocumentedandfiled(forexample,logicdrawings,schematics,sequence/batchdescriptions)?2.9.10Hasallsoftwarebeenproperlyvalidatedandtested?2.9.11Isthereverificationthattheequipmentdoesnotre-start,eitheronthere-settingofaprotectivedevicesuchasaninterlock(safety&non-safety),orthere-establishmentofpowerafteranoutage?3.0ENVIRONMENTAL3.1Areallsecondarycontainment/bondingfacilitiesadequate?3.2Areallmaterialstoragefacilitiesadequateandappropriatelylabeled?3.3Haveadequatearrangementsbeenmade,priortostart-up,fortheidentification,classification,andsafedisposalofallwastematerials?3.4Haveallmaterials,usedinthesystem,beenenteredontheAreaChemicalsInventoryList(orequivalent)?3.5AreupdatedAreaSpillProceduresavailable?3.6ArematerialUnloadingFacilitiesadequateandconstructedinaccordancewithCorporateSafety,Health,andEnvironmentalStandards?Isthereadequatecontainment(110%oftruckvolume)intheunloadingareasforbulkliquidchemicals?3.7HavetheCorporateEnvironmentalGuidelinesbeenfollowedduringthedesignstageofthisproject?3.8Haveallwastestreamsbeenidentified,quantified,analyzedandminimized?3.9ArealloftheapplicableConstruction,EnvironmentalandOperatingPermitsupto-dateandapproved?4.0CAER4.1Haveallnecessaryprecautionsbeentakentoensurethattheequipmentisnotasourceofignitiontoanyflammablematerials,irrespectiveoftheirsource?PSSRITEMCATEGORY/ITEMTOASSESSNotNO.Applicable4.2Arefireprotectionfacilitiesadequateforexample,fireextinguishers,firewalls,sprinklersystems,AlarmBoxes,etc.)?4.3AreEmergencyEscapeRoutes,includingladders,adequateandproperlysignposted?4.4Isemergencylightingadequate?4.5IssufficientRespiratoryProtectiveEquipment,suchasEscapeSetsorSelf-ContainedBreathingApparatus(SCBA)available?4.6HaveEmergencyProceduresbeenpreparedandrelevantpersonneltrained?4.7IstheCommunityPaneladvisedofproposednewmajorprojects?5.1HasanElectricalSafetyChecklist(AcceptanceofElectricalInstallations)beencompletedbyacompetentpersonnel?5.2HastheequipmentbeenproperlyinstalledandconstructedtoCorporateguidelinesandlocallegislation,anddoesitmeetanyspecialinstallationrequirementsnotedonthemanufacturer’scertificate?5.3Hasequipmentbeendesignedandpurchasedfortheconditionsunderwhichitwilloperate(forexample,hazardousareas)?5.4Arealllivepartsadequatelyenclosedtopreventaccess?5.5Doesgroundingandbondingcomplywithcorporateandlocalstandards/legislation?5.6Havefusesorcircuitbreakersbeenprovidedwhichwillautomaticallydisconnectthesupply?5.7AreFirstAidStations,singlelinedrawingsandPPErequirementsavailableinMotorControlCenters(MCC),ElectricalControlRooms(ECR)/Sub-stations,asappropriate?5.8Haveallrelevantdocumentationanddrawings(forexample,P&IDs,SLDs,Schematics,equipmentarrangement,I/O,logic,electricalclassificationandPanelScheduledrawings)beenupdatedtoreflectthecurrentinstallation?5.9HaveallnewSub-stationBreakers,MCCisolators,startersorotherappropriateequipmentbeenregisteredontotheSiteInspectionSchedule?5.10Haveanyelectricalcircuits,maderedundantbythisinstallation,beenproperlyD&R’d?6.0FIELDVERIFICATIONPSSRITEMCATEGORY/ITEMTOASSESSNotNO.Applicable6.1Isthenormallightingadequatefornormalandmaintenanceoperations?6.2Isemergencylightingsufficient?6.3Areallhotandcoldsurfaces,whichmaycauseburns,intheproximityofpersonnelinsulated?6.4Areallinstruments,equipmentandpipingadequatelylabeled?6.5Isthereanyrustedand/ordamagedequipment?6.6Areswinggatesorchainsinstalledatthetopofladdersand/oronaccessplatforms?6.7Arethereanygapsbetweenplatformsandequipmentthatcouldcreateafoothazard?6.8Isequipmentandplatformaccessadequate?6.9Dosafetyshowers/eyewashstationscreateahazardtopersonnel(slips),potentialforcontaminationofproduct(entrytoequipment)oringresstoelectricalequipment?6.10Aresafetyshowersandeyewashstationsadequatelymarkedandreadilyvisible?Istheaccesstothesafetyshowersandey
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 二零二五版汽車銷售合同擔保法執(zhí)行合同3篇
- 2025年環(huán)保節(jié)能建筑材料供應(yīng)合同3篇
- 2025年度個人汽車貸款購車合同(新能源汽車購置補貼合同)3篇
- 長沙幼兒師范高等專科學(xué)?!睹绹膶W(xué)史及選讀(2)》2023-2024學(xué)年第一學(xué)期期末試卷
- 二零二五年度文化產(chǎn)業(yè)股權(quán)投資保密及運營管理協(xié)議3篇
- 校園心理咨詢服務(wù)體系的完善與創(chuàng)新
- 2025年度夫妻忠誠協(xié)議履行監(jiān)督與違約追究協(xié)議4篇
- 學(xué)生實訓(xùn)前安全教育的重要性與策略
- 心理教育課程在學(xué)生心理健康中的重要性
- 個人車輛抵押權(quán)協(xié)議標準范本2024版
- 三角形與全等三角形復(fù)習(xí)教案 人教版
- 2024年1月高考適應(yīng)性測試“九省聯(lián)考”英語 試題(學(xué)生版+解析版)
- 《朝天子·詠喇叭-王磐》核心素養(yǎng)目標教學(xué)設(shè)計、教材分析與教學(xué)反思-2023-2024學(xué)年初中語文統(tǒng)編版
- 成長小說智慧樹知到期末考試答案2024年
- 紅色革命故事《王二小的故事》
- 海洋工程用高性能建筑鋼材的研發(fā)
- 英語48個國際音標課件(單詞帶聲、附有聲國際音標圖)
- GB/T 6892-2023一般工業(yè)用鋁及鋁合金擠壓型材
- 冷庫安全管理制度
- 2023同等學(xué)力申碩統(tǒng)考英語考試真題
- 家具安裝工培訓(xùn)教案優(yōu)質(zhì)資料
評論
0/150
提交評論