空氣調(diào)節(jié)課程設(shè)計

說明書課題名稱:齊南市某街道辦公樓空調(diào)系統(tǒng)學(xué)生學(xué)號:專業(yè)班級: 建筑環(huán)境與能源應(yīng)用工程學(xué)生姓名:學(xué)生成績: 指導(dǎo)教師: 教師職稱:設(shè)計日期:_2017年1月 TOC\o"1-5"\h\z\o"CurrentDocument"第一章設(shè)計資料 5\o"CurrentDocument"1.1設(shè)計題目 5\o"CurrentDocument"1.2設(shè)計基本參數(shù) 5\o"CurrentDocument"1.2.1室外參數(shù) 5\o"CurrentDocument"1.2.2土建參數(shù) 6\o"CurrentDocument"第二章負(fù)荷計算 7\o"CurrentDocument"2.1負(fù)荷計算基本公式 7\o"CurrentDocument"2.1.1外墻、屋頂?shù)乃沧儌鳠岬睦湄?fù)荷 7\o"CurrentDocument"2.1.2內(nèi)圍護(hù)冷負(fù)荷 8\o"CurrentDocument"2.1.3外窗玻璃瞬變傳導(dǎo)得熱形成的的冷負(fù)荷 8\o"CurrentDocument"2.1.4玻璃窗日射得熱形成的冷負(fù)荷 9\o"CurrentDocument"2.1.5設(shè)備散熱冷負(fù)荷 9\o"CurrentDocument"2.1.6燈光照明散熱形成的冷負(fù)荷 9\o"CurrentDocument"2.1.7人體散熱形成的冷負(fù)荷 10\o"CurrentDocument"第三章空調(diào)方案確定和設(shè)備選型 18\o"CurrentDocument"第四章夏季空調(diào)過程設(shè)計 20\o"CurrentDocument"4.1送風(fēng)狀態(tài)確定 21\o"CurrentDocument"4.2匯總于下表 22\o"CurrentDocument"4.3送風(fēng)量計算 23\o"CurrentDocument"4.4新風(fēng)量計算 23\o"CurrentDocument"4.5總排風(fēng)量的計算 24第六章房間的氣流組織計算 27\o"CurrentDocument"6.1氣流組織計算 27\o"CurrentDocument"第七章布置風(fēng)管、進(jìn)行風(fēng)管水力計算,水管水力計算 29\o"CurrentDocument"7.1風(fēng)管的布置 29\o"CurrentDocument"7.2風(fēng)道的設(shè)計及水力計算 30參考文獻(xiàn) 摘要本設(shè)計是濟(jì)南市某街道辦公樓空調(diào)工程設(shè)計,根據(jù)此樓功能要求,本建筑需要夏季提供冷負(fù)荷。以長遠(yuǎn)利益為出發(fā)點,力求達(dá)到技術(shù)可靠,經(jīng)濟(jì)合理,節(jié)能環(huán)保、管理方便,功能調(diào)整的靈活性及使用安全可靠。在比較各種方案的可行性及水系統(tǒng)形式后,此工程設(shè)計采用風(fēng)機(jī)盤管加獨立新風(fēng)系統(tǒng);水系統(tǒng)采用一次泵、雙管制系統(tǒng):為滿足整棟大樓需求,并且為了在運行過程中的節(jié)能,本設(shè)計冷熱源采用風(fēng)冷熱泵模塊機(jī)組。根據(jù)夏季空調(diào)計算負(fù)荷依次選擇機(jī)組、末端設(shè)備、新風(fēng)機(jī)組、風(fēng)口,最后還要對空調(diào)系統(tǒng)的設(shè)備和管路采取消聲、防振和保溫等措施。第一章設(shè)計資料設(shè)計題目濟(jì)南市某街道空調(diào)工程設(shè)計設(shè)計基本參數(shù)室外參數(shù)緯度:28.13度經(jīng)度:112.55度海拔高度:68mAS冬季大氣壓力:1018.3pa夏季大氣壓力:995.6pa冬季通風(fēng)室外計算干球溫度:3.5°C冬季空調(diào)室外計算干球溫度:-0.8°C夏季通風(fēng)室外計算干球溫度:32.2C夏季空調(diào)室外計算干球溫度:36.5C夏季空調(diào)室外計算濕球溫度:29C夏季空調(diào)室外計算日平均溫度:32.5C冬季空調(diào)室外相對濕度:90%夏季通風(fēng)室外相對濕度:63%冬季室外平均風(fēng)速:2.4m/s夏季室外平均風(fēng)速:2.4m/s土建參數(shù)1外墻參數(shù):通過查資料,選擇23號外墻,其基本構(gòu)造為:1、水泥砂漿抹灰加淺色噴漿;2、磚墻;3、保溫層為硬質(zhì)聚氨酯板;6=50mm,K=0.51W/( ?K),衰減系數(shù)B=0.19,延遲時間為8h.2內(nèi)墻參數(shù):選擇10號墻磚,6=140mm,K=1.78W/(?K),衰減系數(shù)為0.29,延遲時間為7h.3屋面參數(shù):選擇10號保溫層面,基本結(jié)構(gòu),1、混凝土板;2、架空層;3、防水層;4、找平層;5、找坡層;6、加氣混凝土7、保溫層8、鋼筋混凝土屋面板。其中保溫層為擠塑聚苯板,6=40mm,K=0.59W/(tf?K),衰減系數(shù)為0.22,延遲時間為8h。4樓板參數(shù):選擇3號鋼筋混凝土樓板,由面層、鋼筋混凝土樓板、吊頂空間、鋼板網(wǎng)抹灰、濁漆組成。5外窗參數(shù):選擇6mm厚度單層鋁合金框架玻璃窗傳熱系數(shù)K=3.3W/(tf?K),內(nèi)遮陽系數(shù)Cn=0.5,地點修正系數(shù):南面》=1.08北面xd=1.00,東面和西面xd=L05,xg-0.75,遮擋系數(shù)C二0.78。第二章負(fù)荷計算負(fù)荷計算基本公式內(nèi)墻、內(nèi)窗、地板等其鄰室為空調(diào)房間時,其室溫基數(shù)差小于3°C時,不計算冷負(fù)荷。所以負(fù)荷計算時,室溫基數(shù)差小于3°C的都不用考慮樓板和內(nèi)墻的傳熱。外墻、屋頂?shù)乃沧儌鳠岬睦湄?fù)荷根據(jù)《實用供熱空調(diào)設(shè)計手冊》得,在日射和室外氣溫綜合作用下,外墻和屋面瞬變傳熱引起的逐時冷負(fù)荷可按式2.1計算。CLQt二KF(t+A-1)gn (公式0.1)式中:計算時間,h;e——圍護(hù)結(jié)構(gòu)表面受到周期為24h諧性溫度波作用,溫度波傳到內(nèi)表面的時間延遲,h;T-S――溫度波的作用時間,即溫度作用于圍護(hù)結(jié)構(gòu)外表面的時刻,h;K圍護(hù)結(jié)構(gòu)傳熱系數(shù),w/(m2?K);F——圍護(hù)結(jié)構(gòu)計算面積,m2;t—作用時刻下,圍護(hù)結(jié)構(gòu)的冷負(fù)荷計算溫度,簡稱冷負(fù)荷T-£溫度,°c;A—負(fù)荷溫度地點修正值,c,+1;t—室內(nèi)設(shè)計溫度,c。n

內(nèi)圍護(hù)冷負(fù)荷由于相鄰空間通風(fēng)良好,臨室發(fā)熱量很少,僅由于溫差形成內(nèi)(公式0.2)圍護(hù)冷負(fù)荷,屬于穩(wěn)定傳熱,根據(jù)參考資料[1]可得計算公式(公式0.2)Q=kf(t-1)wpn式中:k圍護(hù)結(jié)構(gòu)傳熱系數(shù),W/(m2?K);F——圍護(hù)結(jié)構(gòu)計算面積,m2;t――夏季空調(diào)室外計算日平均溫度,。c;wpt——室內(nèi)設(shè)計溫度,c。n外窗玻璃瞬變傳導(dǎo)得熱形成的的冷負(fù)荷在室內(nèi)外溫差的作用下,玻璃窗瞬傳熱形成的冷負(fù)荷可按式2.3計算。(公式Q二aKF(t+8-1)Tg 0.3)式中:K 窗玻璃的傳熱系數(shù),W/(m2?K);F――窗的計算面積,m2;t――計算時刻下的冷負(fù)荷溫度,c;T8――地點修正系數(shù),C;t——室內(nèi)設(shè)計溫度,c;na——窗框修正系數(shù)。

玻璃窗日射得熱形成的冷負(fù)荷透過玻璃窗進(jìn)入室內(nèi)的日射得熱形成的逐時冷負(fù)荷按式2.4計(公式0.4(公式0.4)Q二XXXFJ工 gdzn&式中:X——窗的構(gòu)造修正系數(shù);gX——地點修正系數(shù);dX——內(nèi)遮陽系數(shù);zJ——計算時刻下,透過有內(nèi)遮陽設(shè)施窗玻璃太陽輻射的冷nT負(fù)荷強(qiáng)度,Wm2。設(shè)備散熱冷負(fù)荷(公式Q=Fqff 0.5)式中:F——空調(diào)區(qū)面積,m2。qf一一電器設(shè)備功率密度,W/m2。燈光照明散熱形成的冷負(fù)荷白熾燈散熱形成的冷負(fù)荷按照式2.6計算。(公式Q=nNXT1t-T 0.6)式中:n――同時使用系數(shù),由于缺少實測數(shù)據(jù),取n=0.6?0.8;11

t 計算時刻,h;T——開燈時刻,h;t-T從開燈時刻算起到計算時刻的持續(xù)時間,h;X一一T-T時刻燈具顯熱散熱的冷負(fù)荷系數(shù);t-TN一一照明燈具所需功率,缺少數(shù)據(jù)時,可根據(jù)空調(diào)使用面積推算功率指標(biāo)W。人體散熱形成的冷負(fù)荷人員的冷負(fù)荷包括人員顯熱和潛熱部分,顯熱部分需要進(jìn)行逐時計算,而潛熱由于變化范圍較小,按穩(wěn)定傳熱計算。根據(jù)參考資料得:a.人體顯熱形成的計算時刻冷負(fù)荷按照公式2.7計算公式Q=Q=9nqXT 1T-T0.7)式中:廠一不同室溫和勞動性質(zhì)時一名成年男子小時顯熱散熱量,W;計算時刻空調(diào)區(qū)內(nèi)的總?cè)藬?shù);群集系數(shù);T一一計算時刻,h;T一一人員進(jìn)入空調(diào)區(qū)的時刻,h;t-T從人員進(jìn)入空調(diào)區(qū)的時刻算起到計算時刻的持續(xù)時間h;

T-T-T時刻人體顯熱散熱的冷負(fù)荷系數(shù)。T-Tb.人體散濕形成的潛熱冷負(fù)荷玖(W)計算公式:(公式0.8)式中:。2--不同室溫和勞動性質(zhì)時一名成年男子小時潛熱散熱量,W;計算時刻空調(diào)區(qū)內(nèi)的總?cè)藬?shù)群集系數(shù)。濟(jì)南市在西安市修正+1101房間負(fù)荷計算南墻冷負(fù)荷:時間9::0010::0011::0012::0013::0014::0015::0016::0017::00tC(T)31.831.831.832.032.332.933.634.234.9At+1tC'(T)32.832.832.833.033.333.934.635.235.9tR26K0.45A10.8QC(t)28.0728.0728.0728.9030.1332.6135.5037.9840.87南窗冷負(fù)荷:時間9::0010::0011::0012::0013::0014::0015::0016::0017::00tC(T)31.031.732.333.033.433.733.833.633.4tR26K2.4A4.8QC(t)57.665.6672.5880.6485.2588.7089.8687.5585.25南外窗日射負(fù)荷時間9::0010::0011::0012::0013::0014::0015::0016::0017::00CLQ0.300.400.510.530.670.680.650.440.39Ca0.75Aw4.8Cs0.78c.i0.6D.243jmaxQc(t)122.8163.7208.8216.9274.3278.4266.1180.1159.6260900147西外墻冷負(fù)荷時間9::0010::0011::0012::0013::0014::0015::0016::0017::00tc(J34.234.033.833.833.934.134.434.935.7At+1

tC'(T)35.235.034.834.834.935.135.435.936.7tR26K0.43A21.6QC(t)85.4583.5981.7381.7382.6684.5287.3191.9599.38照明散熱冷負(fù)荷時間9::0010::0011::0012::0013::0014::0015::0016::0017::00CLQ0.40.720.770.810.830.850.870.890.9ni1門20.6N232QC(t)55.68100.2107.1112.7115.5118.3121.1123.8125.228542098室內(nèi)人員散熱冷負(fù)荷時間9::0010::0011::0012::0013::0014::0015::0016::0017::00CLQ0.460.780.830.860.880.890.910.920.93qs60.5n50.90125.2212.3225.9234.1239.5242.3247.7250.4253.1467480579qi73.3329.8329.8329.8329.8329.8329.8329.8329.8329.8555555555QC(t)455.0542.2555.8563.9569.4572.1577.6580.3583.0912935024101房間各負(fù)荷匯總表時間9::0010::0011::0012::0013::0014::0015::0016::0017::00南墻28.0728.0728.0728.9030.1332.6135.5037.9840.87西墻85.4583.5981.7381.7382.6684.5287.3191.9599.38外窗57.665.6672.5880.6485.2588.7089.8687.5585.25窗日照122.82163.76208.8216.99274.3278.4266.11180.14159.67人體455.09542.21555.82563.99569.43572.15577.6580.32583.04

照明55.68100.22107.18112.75115.54118.32121.1123.89125.28合計804.71983.511054.110851157.31174.71177.41101.81093.481839102-108房間各負(fù)荷匯總表時間9::0010::0011::0012::0013::0014::0015::0016::0017::00南墻28.0728.0728.0728.9030.1332.6135.5037.9840.87外窗57.665.6672.5880.6485.2588.7089.8687.5585.25窗日照122.82163.76208.8216.99274.3278.4266.11180.14159.67人體455.09542.21555.82563.99569.43572.15577.6580.32583.04照明55.68100.22107.18112.75115.54118.32121.1123.89125.28合計719.05899.92972.451003.21082.11090.11056.21105.21093.4758559109房間各負(fù)荷匯總表時間9::0010::0011::0012::0013::0014::0015::0016::0017::00南墻28.0728.0728.0728.9030.1332.6135.5037.9840.87東墻85.4583.5981.7381.7382.6684.5287.3191.9599.38外窗65.4865.6672.5880.6485.2588.7089.8687.5585.25窗日照122.82163.76208.8216.99274.3278.4266.11180.14159.67人體455.09542.21555.82563.99569.43572.15577.6580.32583.04照明88.68100.22107.18112.75115.54118.32121.1123.89125.28合計935.561065.51158.21284.41305.21358.11358.11335.81315.224145555110-112.114.115房間各負(fù)荷匯總表時間9::0010::0011::0012::0013::0014::0015::0016::0017::00北墻85.4583.5981.7381.7382.6684.5287.3191.9599.38外窗57.665.6672.5880.6485.2588.7089.8687.5585.25窗日照122.82163.76208.8216.99274.3278.4266.11180.14159.67人體455.09542.21555.82563.99569.43572.15577.6580.32583.04照明55.68100.22107.18112.75115.54118.32121.1123.89125.28合計776.64955.441026.111056.11127.181142.091141.981063.851052.62

113房間各負(fù)荷匯總表時間9::0010::0011::0012::0013::0014::0015::0016::0017::00北墻170.9167.18163.46163.46165.32169.04174.62183.9198.76外窗115.2131.32145.16161.28170.5177.4179.72175.1170.5窗日照245.64327.52417.6433.98548.6556.8532.22360.28319.34人體910.181084.421111.641127.981138.861144.31155.21160.641166.08照明111.36200.44214.36225.5231.08236.64242.2247.78250.56合計1553.281910.882052.222112.22254.362284.182283.962127.72105.24各房間負(fù)荷匯總表房間號一層房間濕負(fù)荷時間9::0010::0011::0012::0013::0014::0015::0016::0017::000.49101804.7983.51054.10851157.1174.1177.1101.1093.0.491118317488349102719.0899.9972.41003.1082.1090.1056.1105.1093.0.49525271518252549103719.0899.9972.41003.1082.1090.1056.1105.1093.0.49525271518252549104719.0899.9972.41003.1082.1090.1056.1105.1093.0.49525271518252549105719.0899.9972.41003.1082.1090.1056.1105.1093.0.49525271518252549106719.0899.9972.41003.1082.1090.1056.1105.1093.0.49525271518252549107719.0899.9972.41003.1082.1090.1056.1105.1093.0.49525271518252549108719.0899.9972.41003.1082.1090.1056.1105.1093.0.49525271518252549109935.51065.1158.1284.1305.1358.1358.1335.1315.0.4965224412415158525110776.64955.441026.11056.11127.11142.01141.91063.81052.60.49189852111776.64955.441026.11056.11127.11142.01141.91063.81052.60.49189852112776.64955.441026.11056.11127.11142.01141.91063.81052.60.49189852

1131553.281910.882052.222112.22254.362284.182283.962127.72105.240.98114776.64955.441026.11056.11127.11142.01141.91063.81052.60.49189852115776.64955.441026.11056.11127.11142.01141.91063.81052.60.49189852門廳855.1895.2925.2102.5962.11025.1056.986.2961.22.9555531252356

房間號二層房間濕負(fù)荷時間9::0010::0011::0012::0013::0014::0015::0016::0017::000.49201903.51125.1205.1256.1324.1356.1389.1305.1283.0.495251112158535858202905.51025.1105.1225.1262.1295.1272.1220.1195.0.492546556524552424203905.51025.1105.1225.1262.1295.1272.1220.1195.0.492546556524552424204905.51025.1105.1225.1262.1295.1272.1220.1195.0.4925465565245524242051811.2051.2211.2451.2525.2590.2545.2440.2390.0.98040831204904848206905.51025.1105.1225.1262.1295.1272.1220.1195.0.492546556524552424207905.51025.1105.1225.1262.1295.1272.1220.1195.0.492546556524552424208905.51025.1105.1225.1262.1295.1272.1220.1195.0.492546556524552424209950.21152.1258.1283.1345.1386.1393.1423.1410.0.4954125122525255652210910.21056.1125.1175.1208.1256.1286.1298.1274.0.4952865562525252525211910.21056.1125.1175.1208.1256.1286.1298.1274.0.4952865562525252525212910.21056.1125.1175.1208.1256.1286.1298.1274.0.49528655625252525252131820.2112.2251.2351.2416.2512.2572.2596.2548.0.9855631255555樓梯450.5525.4592.5608.2656.2698.1702.2697.2710.20.49間844555553214910.21056.1125.1175.1208.1256.1286.1298.1274.0.4952865562525252525215910.21056.1125.1175.1208.1256.1286.1298.1274.0.4952865562525252525門廳352.2365.2381.56369.2421.2458.2421.2423.2395.21.965555555第三章空調(diào)方案確定和設(shè)備選型空調(diào)系統(tǒng)的分類方案確定空調(diào)系統(tǒng)按負(fù)擔(dān)室內(nèi)空調(diào)負(fù)荷所用介質(zhì)分類,可分為全空氣系統(tǒng)、全水系統(tǒng)、空氣-水系統(tǒng)和冷劑式系統(tǒng)。一、全空氣系統(tǒng)是指室內(nèi)空調(diào)負(fù)荷全部由處理過的空氣負(fù)擔(dān)。系統(tǒng)適用性:1、建筑空間大,易于布置風(fēng)道;2、室內(nèi)溫、濕度、潔凈度控制要求嚴(yán)格;3、負(fù)荷大或潛熱負(fù)荷大的場合。二、全水系統(tǒng)是指室內(nèi)空調(diào)負(fù)荷全部由水來負(fù)擔(dān)。系統(tǒng)適用性:1、建筑空間小,不宜于布置風(fēng)道;2、不需通風(fēng)換氣的場所。三、空氣-水系統(tǒng)是指室內(nèi)空調(diào)負(fù)荷由空氣和水共同負(fù)擔(dān)。1、室內(nèi)溫、濕度要求一般的場合;2、層高較低的場合;3、冷負(fù)荷較小、濕負(fù)荷也較小的場所。四、冷劑式系統(tǒng)是指空調(diào)房間負(fù)荷由制冷劑直接承擔(dān)。1、空調(diào)房間布置分散;2、要求靈活控制空調(diào)使用時間;3、無法集中設(shè)置冷熱源。全空氣一次回風(fēng)系統(tǒng)的空調(diào)機(jī)組送風(fēng)量是恒定的,系統(tǒng)的夏季冷量由室內(nèi)冷負(fù)荷、新風(fēng)負(fù)荷和再熱負(fù)荷組成,對于送風(fēng)溫差無嚴(yán)格要求的舒適性空調(diào),如采用大溫差送風(fēng)即露點送風(fēng)的一次回風(fēng)系統(tǒng),可不需要消耗再熱量,因此可節(jié)省能耗。但送風(fēng)溫差過大,往往會造成送風(fēng)口解霜現(xiàn)象,為避免此類現(xiàn)象的發(fā)生,采用一次回風(fēng)空調(diào)系統(tǒng)需利用再熱來解決送風(fēng)溫差受限制的問題,即為了保證必須的送風(fēng)溫差,一次回風(fēng)系統(tǒng)在夏季需要再熱,從而產(chǎn)生冷熱抵消的現(xiàn)象風(fēng)機(jī)盤管加新風(fēng)系統(tǒng)是空氣-水系統(tǒng)的一種主要形式,也是我國民用建筑中采用最普遍的一種空調(diào)方式,它的投資少,使用靈活和節(jié)省建筑空間等優(yōu)點被廣泛應(yīng)用于各類建筑中。該系統(tǒng)具有以下特點:本設(shè)計為培訓(xùn)中心,通過對上述空調(diào)系統(tǒng)的分析,本設(shè)計采用空氣-水系統(tǒng)。新風(fēng)系統(tǒng)的形式采用分樓層水平式,每層設(shè)置新風(fēng)系統(tǒng),采用風(fēng)機(jī)盤管加新風(fēng)系統(tǒng),新風(fēng)處理方式不一樣,對室內(nèi)空氣品質(zhì)有很大的影響。風(fēng)機(jī)盤管加新風(fēng)系統(tǒng)的空氣處理方式有:(1)新風(fēng)處理到室內(nèi)狀態(tài)的等焓線,不承擔(dān)室內(nèi)負(fù)荷;(2)新風(fēng)處理到低于室內(nèi)空氣的焓值,并低于室內(nèi)空氣的含濕量,承擔(dān)部分室內(nèi)負(fù)荷。這里選用不承擔(dān)室內(nèi)冷負(fù)荷方案,在每層的空調(diào)機(jī)房處設(shè)置一新風(fēng)處理機(jī)組,負(fù)擔(dān)新風(fēng)負(fù)荷,新風(fēng)不與風(fēng)機(jī)盤管回風(fēng)混合,新風(fēng)口單獨送風(fēng)。第四章夏季空調(diào)過程設(shè)計4.1送風(fēng)狀態(tài)確定空氣—水系統(tǒng)是由空氣和水共同來承擔(dān)空調(diào)房間冷、熱負(fù)荷的系統(tǒng),除了向房間內(nèi)送入經(jīng)過處理的空氣外,還在房間內(nèi)設(shè)有以水作為介質(zhì)的末端設(shè)備對室內(nèi)空氣進(jìn)行冷卻或加熱。新風(fēng)將不在承擔(dān)室內(nèi)負(fù)荷,將新風(fēng)處理到室內(nèi)空氣的焓值,而風(fēng)機(jī)盤管承擔(dān)室內(nèi)人員設(shè)備冷負(fù)荷和建筑維護(hù)結(jié)構(gòu)冷負(fù)荷。氣一一水系統(tǒng)送風(fēng)狀態(tài)的確定可在i-d圖上進(jìn)行,具體步驟如下:1) 在i-d圖上找出室內(nèi)狀態(tài)點N,室外狀態(tài)點W。2) 根據(jù)計算出來的室內(nèi)冷負(fù)荷Q和濕負(fù)荷W求出J過N點作線與申=90%相交,即得送風(fēng)點S。3) 根據(jù)等焓線,由新風(fēng)處理后的機(jī)器露點相對濕度定出D點。4) 根據(jù)N、S兩點確定房間總風(fēng)量。5) 根據(jù)新風(fēng)比確定風(fēng)機(jī)盤管處理風(fēng)量即終狀態(tài)。其中,人體散濕量M=0.278n申gX10-6wM 人體散濕量,kg/s;wg c成年男子小時散熱量,g/h。

4.2匯總于下表熱濕負(fù)荷與熱濕比最大冷負(fù)荷人數(shù)成年男子小時散濕量濕負(fù)荷熱濕比房間編號Q(W)cin(人)g(g/h)M(g/s)wi£(kJ/kg)i1011157.3151090.1369852102至1081105.2551090.13699621091358.1551090111、112、1142.0951090.1369758114、1151132868.41101090.27210355門廳458.2511090.027102352011389.53510902081295.4551090.136112562052590.9101090.272118652091423.5651090211、212、1298.25510902152132596.5101090.272113654.3送風(fēng)量計算送風(fēng)量的計算公式為:M=c——

sh-hsRM――送入房間的風(fēng)量,kg/s;sQ——全熱冷負(fù)荷,KW;C(T)h——室內(nèi)空氣的比焓,k/k;R Jghs 送風(fēng)的比焓,k/koJg4.4新風(fēng)量計算4.3.1人員所需新風(fēng)量的計算公式為:M=ngo1 W式中n——每個房間人數(shù);g 沒人所需新風(fēng)量,m3/人?h。w4.3.2為維持房間正壓所需的新風(fēng)量計算公式為M=NV

o2式中N——換氣次數(shù),/h;V房間體積,m3;新風(fēng)量取兩者中最大值。各房間總風(fēng)量、新風(fēng)量如下表4.5總排風(fēng)量的計算Mp70%Mo房間編號新風(fēng)量排風(fēng)量kg/sma/skg/sma/s1010.050.040.040.03102至1080.050.040.040.031090.050.040.040.03110、111、112、114、1150.050.040.040.031130.100.080.070.06門廳0.010.0080.0070.006一樓總0.8010.6750.5610.4732010.050.040.040.03202至2080.050.040.040.032050.100.080.070.062090.050.040.040.03210、211、212、214、2150.050.040.040.032130.100.080.070.06二樓總0.850.7080.5950.496第五章空調(diào)制冷設(shè)備選型新風(fēng)機(jī)組的選型一層二層采用空氣——水風(fēng)機(jī)盤管系統(tǒng),對新風(fēng)機(jī)組進(jìn)行選型。一層承擔(dān)總的新風(fēng)量為1985m3/h,承擔(dān)的新風(fēng)冷量為15.2KW,所查得的型號為ZKD3-X二層承擔(dān)總的新風(fēng)量為2015m3/h,承擔(dān)的新風(fēng)冷量為15.8KW,所查得的型號為ZKD3-X5.2風(fēng)機(jī)盤管的選型對于該系統(tǒng),風(fēng)機(jī)盤管的冷負(fù)荷即為室內(nèi)冷負(fù)荷,風(fēng)機(jī)盤管所承擔(dān)的風(fēng)量為送風(fēng)量-新風(fēng)量。以前室房間為例,該房間的冷負(fù)荷為1583.53W,風(fēng)機(jī)盤管所承擔(dān)的風(fēng)量為承擔(dān)的風(fēng)量為315m3/h。查得風(fēng)機(jī)盤管的型號為FP—34。各房間風(fēng)機(jī)盤管型號房間編號風(fēng)機(jī)盤管型號101FP-34WA

102至108FP-34WA109FP-34WA110、111、112、114、FP-34WA115113FP-68WA門廳FP-34WA201FP-51WA202至208FP-34WA209FP-51WA210、211、212、214、FP-34WA215213FP-68WA第六章房間的氣流組織計算6.1氣流組織計算采用散流器平送氣流組織形式,徑向貼附散流器,送出的氣流為貼附于頂棚的射流,回風(fēng)口布置在房間下部。因散流器服務(wù)的長寬比大于1.25時,采用矩形散流器。散流器中心與側(cè)墻的距離不小于lm。房間尺寸為7.2X4X3.6(長X寬X高),(以901房間為例)。、按兩個散流器布置,則散流器所對應(yīng)的Fn=4X3.6=14.4^,水平射程分別為2m及1.8m,平均取i=1.9m,垂直射程x'=3.6-2=1.6m.、設(shè)送風(fēng)溫差t=6°C,因此總送風(fēng)量為oL二1743.5X3.6三(1.2X1.01X6)=863.1m3/h換氣次數(shù):n=863.1三(7.2X3.6X4)=8.3l/h按照兩個散流器布置,每個散流器的送風(fēng)量為L0=863.1/2=431.55m3/h、散流器出風(fēng)速度u選定為3.0m/s,這樣:f=431.55三00(3.0X3600)=0.04、檢查u,根據(jù)式5.1得到。公式公式、迂mKKKJFTOC\o"1-5"\h\zU=U 1_12 Ox0 x'+1 0.1)式中:邁m=1.41;1K——根據(jù)0.11/苗=0.1上=0.95,查圖5-13,按1 、0 10.04//x'=1.9/1.6=1.188查得k=0.49;1K、K——均取1.23代入各已知值得:U=0.118m/s。x、檢查At:At二At叫0'化=0.21°Cxx0x'+1根據(jù)資料推薦的送風(fēng)溫差和換氣次數(shù),計算結(jié)果說明At及u均滿足xx要求。、檢查射流貼附長度x:1x=0.4zexpk(其中h0=0.3d0)1TOC\o"1-5"\h\zz=5.45£2mu4 0 =3.781叫苗nAt)2T1 0所以x=0.4X3.78Xexp(0.35-0.62h/品f0)=2.03m〉1.9ml O因此,貼附射流長度滿足要求。散流器的選擇房間編號房間面枳風(fēng)口尺寸風(fēng)口個數(shù)SmmXmmn10121.06100*3001102至10821.06100*300110921.06100*4001110至11521.06100*300111342.12100*300220121.06100*4001202至20821.06100*400120542.12100*400220921.06100*4001210至21521.06100*300121342.12100*3002第七章布置風(fēng)管、進(jìn)行風(fēng)管水力計算,水管水力計算7.1風(fēng)管的布置(1)送風(fēng)口:該會議室采用散流器送風(fēng),根據(jù)《民用建筑空調(diào)系統(tǒng)建筑手冊》可查得散流器布置的原則是:布置時充分考慮建筑結(jié)構(gòu)的特點,散流器平送方向不得有障礙物(如柱);一般按對稱布置或梅花形布置;每個方行散流器所服務(wù)的區(qū)域最好為正方形或接近正方形;如果散流器服務(wù)區(qū)的長度比大于1.25時,宜選用矩形散流器;如果采用頂棚回風(fēng),則回風(fēng)口應(yīng)布置在距散流器最遠(yuǎn)處。散流器送風(fēng)氣流分布計算,主要選用合適的散流器,使房間內(nèi)風(fēng)速滿足設(shè)計要求。此外,散流器中心與側(cè)墻的距離不宜小于lm,4mX4m的散流器,間距一般在3.5米。(2)風(fēng)管的布置及附件:?風(fēng)管道全部用鍍鋅鋼板制作,厚度及加工方法,按《通風(fēng)與空調(diào)工程施工及驗收規(guī)范》(GB50243-97)的規(guī)定確定,主管和支管的斷面尺寸在途中標(biāo)明;設(shè)計圖中所注風(fēng)管的標(biāo)高,以風(fēng)管底為準(zhǔn);穿越沉降縫或變形縫處的風(fēng)管兩側(cè),以及與通風(fēng)機(jī)進(jìn)、出口相連處,應(yīng)設(shè)置長度為200?300mm的人造革軟接;軟接的接口應(yīng)牢固、嚴(yán)密。在軟接處禁止變徑;風(fēng)管上的可拆卸接口,不得設(shè)置在墻體或樓板內(nèi);所有水平或垂直的風(fēng)管,必須設(shè)置必要的支、吊或托架,其構(gòu)造形式由安裝單位在保證牢固、可靠的原則下根據(jù)現(xiàn)場情況選定,詳見國標(biāo)T616;風(fēng)管支、吊或托架應(yīng)設(shè)置于保溫層的外部,并在支吊托架與風(fēng)管間鑲以墊木,同時,應(yīng)避免在法蘭、測量孔、調(diào)節(jié)閥等零部件處設(shè)置支吊托架;安裝調(diào)節(jié)閥、蝶閥等調(diào)節(jié)配件時,必須注意將操作手柄配置在便于操作的部位;安裝防火閥和排煙閥時,應(yīng)先對其外觀質(zhì)量和動作的靈活性與可靠性進(jìn)行檢驗,確認(rèn)合格后再行安裝;防火閥的安裝位置必須與設(shè)計相符,氣流方向務(wù)必與閥體上標(biāo)志的箭頭相一致,嚴(yán)禁反向;防火閥必須單獨配置支吊架;每個風(fēng)支管都接防火調(diào)節(jié)閥。風(fēng)道的設(shè)計及水力計算風(fēng)管水力計算方法有假定流速法、壓損平均法和靜壓復(fù)得法等幾種,這里采用假定流速法,假定流速法的特點是先按技術(shù)經(jīng)濟(jì)要求選定風(fēng)管的流速,再根據(jù)風(fēng)管的風(fēng)量確定風(fēng)管的斷面尺寸和阻力。(1)繪制空調(diào)系統(tǒng)軸測圖,并對管段風(fēng)道進(jìn)行編號,標(biāo)準(zhǔn)長度和風(fēng)量(管道長度一般按兩個管件的中心線長度計算,不扣除管件本身的長度)。(2) 確定風(fēng)道內(nèi)的合理流速,在輸送空氣量一定的情況,增大流速可是風(fēng)管斷面積減小,制作風(fēng)管所消耗的材料,建筑費用等較低,但同時也會增加空氣流經(jīng)風(fēng)管的流動阻力和氣流噪聲,增

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

最新文檔

評論

0/150

提交評論