1Generalprovisions
Thisstandardispreparedwithaviewtoimplementtheconceptofgreendevelopment,promotethehigh-qualitydevelopment,saveresources,protecttheenvironment,reducecarbonemissionsfromconstruction,promoteharmonybetweenmanandnature,improvethelivingenvironmentincountriesalongtheSilkRoadEconomicBeltandthe21st-CenturyMaritimeSilkRoad,andsupportthepromotionofgreenbuildingsinthosecountries
ThisstandardisapplicabletotheassessmentonthegreenperformanceofcivilbuildingsincountriesalongtheSilkRoadEconomicBeltandthe21st-CenturyMaritimeSilkRoad.
Theassessmentofgreenbuildingshallfollowtheprincipleofadaptingtolocalconditions,inconsiderationoftheclimate,environment,resources,economy,culture,etc.ofthecountryorregionwherethebuildingsarelocated,andthenmakeacomprehensiveassessmentofthebuildingsintermsofsafetyanddurability,healthandcomfort,occupantconvenience,resourcessavingandenvironmentlivabilityduringthewholelifecycleofthebuildings.
Greenbuildingshallbecombinedwithlandformsforsitedesignandbuildinglayout,andbuildinglayoutshallbeadaptedtotheclimaticconditionsandgeographicalenvironmentofthesite;meanwhile,thewind,light,thermalandacousticenvironmentsofthesiteshallbeconsideredandused.
Inadditiontotherequirementsstipulatedinthisstandard,theassessmentofgreenbuildingshallcomplywiththosestipulatedinthecurrentrelevantlocalstandards.
2Terms
GreenBuilding
Thehigh-qualitybuildingthatisabletosavetheresources,protecttheenvironmentandreducepollutiontoprovidepeoplewithahealthy,applicableandefficientspaceandmaximallyrealizeharmoniouscoexistencewiththenatureduringitswholelifecycle.
GreenPerformance
Thecomprehensiveperformanceofbuildingintermsofsafetyanddurability,healthandcomfort,occupantconvenience,resourcesaving(landsaving,energysaving,watersavingandmaterialsaving)andenvironmentallivability.
WaterQualityRegularIndices
Thewaterqualityindexthatcanreflectthebasicconditionofdrinkingwaterquality
WeightedStandardizedLevelDifference
Thesinglenumberquantityoftheairbornesoundinsulationperformancebetweentworoomsobtainedbyusingthereverberationtimeofthereceivingroomasamodifiedparameter.
ValueOfDaylightFactor
Theratioofilluminancedirectlyorindirectlyreceivedfromtheassumedandknowndistributeddiffuseskylightfromatapointontheindoorsworkingplanetothesimultaneousoutdoorilluminanceonahorizontalplanefromanunobstructedhemisphereofovercastsky.
LightingPowerDensity
Installationpowerperunitareaofgenerallighting(includingauxiliaryelectricaldevicessuchaslightsources,ballastsortransformers)inwattspersquaremeter(W/m2).
BioclimaticDesign
Architecturaldesignmethodthatconsistentwiththelocalnaturalenvironment,whichcanpromoteenvironmentalsustainabilityandbringpeoplepleasantandcomfort.
GreenBuildingMaterial
Thebuildingmaterialswiththecharacteristicsofenergy-saving,emissionreduction,safety,health,convenienceandrecyclability,whichcanreducetheconsumptionofresourcesandtheimpactontheecologicalenvironmentduringthewholelifecycle.
HeatIslandIntensity
Acharacterizationparameteroftheurbanheatislandeffect,bywhichthedifferencesoftheairtemperaturebetweenoneurbanareaandthesuburbareaisexpressedbythetemperaturedifferencebetweenthetypicalmeasuringpoints.
3BasicRequirements
3.1GeneralRequirements
Assessmentofgreenbuildingshalltakeasinglebuildingoragroupofbuildingsastheassessedobject;theassessmentindexesinvolvingsystemicandholisticcharacteristicsshallbebasedontheoverallprojecttowhichthebuildingbelongs.
Theassessmentofgreenbuildingincludestwoparts:Pre-assessmentshallbeconductedafterthecompletionoftheconstructiondrawingdesign;assessmentshallbeconductedafterconstruction.
Theapplicantforgreenbuildingassessmentshallconductthetechnicalandeconomicanalysisonthebuildingsduringthewholelifecycle,selectappropriatetechnologies,equipmentandmaterials,controlthewholeprocessoftheplanning,design,constructionandoperation,andsubmitcorrespondinganalysisandtestreportsaswellasrelateddocuments.Theapplicantshallalsoberesponsiblefortheauthenticityandintegrityofthesubmittedassessmentmaterials.
Theassessmentorganizationshallverifytheanalysis,testreportsandrelateddocumentssubmittedbytheapplicant,issueanassessmentreportandspecifythegrade.
Buildingsapplyingforgreenfinancialservicesshallbecalculatedandexplainedintermsofenergysavingmeasures,watersavingmeasures,buildingenergyconsumptionandcarbonemissions,andshallformaspecialreport
3.2AssessmentandRating
Theassessmentindexsystemofgreenbuildingshallconsistoffivecategoriesofindexessafetyanddurability,healthandcomfort,occupantconvenience,resourcessavingandenvironmentlivability.Eachcategoryofindexesincludesprerequisiteitemsandscoringitems.Theassessmentindexsystemisalsouniformlyprovidedwithbonusitems.
Theassessmentresultoftheprerequisiteitemsshallbe"pass"or"fail";theassessmentresultofthescoringitemsandthebonusitemsshallbescore
Asforamultifunctionalandcomprehensiveindividualbuilding,theapplicableareasshallbeassessedinaccordancewithalltheprovisionsspecifiedinthisstandardonebyonetodeterminethescoreofeachprovision.
ThescoresofgreenbuildingassessmentshallbeinaccordancewiththerequirementsspecifiedinTable3.2.4
表3.2.4ScoresofGreenBuildingAssessment
Basicscoreforprerequisiteitems
Fullscoreofscoringitemsforassessmentindex
Fullscoreofbonusitemsdoepromotionandinnovation
Safetyanddurability
Healthandcomfort
Occupantconvenience
Resourcessaving
Environmentlivability
Pre-assessmentscore
400
100
100
70
200
100
100
Assessmentscore
400
100
100
100
200
100
100
Thetotalscoreoftheassessmentofgreenbuildingiscalculatedusingthefollowingequation:
Q=(Q0+Q1+Q2+Q3+Q4+Q5+QA)/10(3.2.5)
Where:Q——thetotalscore;
Q0——thebasicscoreoftheprerequisiteitems,whichisscored400pointswhenalltheprerequisiteitemsarepassed;
Q1~Q5——thescoresofthescoringitemsoffivecategories(safetyanddurability,healthandcomfort,occupantconvenience,resourcessavingandenvironmentlivability);
QA——thescoreofbonusitemsforopennessandinnovation.
Greenbuildingsshallbedividedintofourgrades:basic,one-star,two-starandthree-star.
Whentherequirementsofallprerequisiteitemsaremet,thegreenbuildinggradeshallbethebasicgrade.
Thestargradeofgreenbuildingshallberatedaccordingtothefollowingrequirements:
1Greenbuildingsofone-star,two-starandthree-starshallmeettherequirementsofallprerequisiteitemsinthisstandardandthescoreforscoringitemsofeachcategoryofindexshallnotbelessthan30%ofitsfullscore;
2Whenthetotalscorereaches60points,70points,85pointsrespectively,thegreenbuildingsareratedasthegradeofone-star,two-starandthree-starrespectively
4SafetyandDurability
4.1PrerequisiteItems
Siteswithgeologicalriskssuchaslandslidesandmudslidesshallbeavoided.Flood-proneareasshallbeprovidedwithflood-proofinfrastructure,termitepreventionandcontrolshallbedoneinareasvulnerabletotermiteinfestation;thesitesshallbefreefromthethreatsofdangerouschemicals,inflammableandexplosivesourcesaswellasthehazardsofelectromagneticradiationandradon-containingsoil.
Thebuildingstructureshallmeettherequirementsforbearingcapacityandbuildingfunction.Buildingenvelopessuchastheexteriorwall,roofing.doorsandwindows,curtainwallsandexteriorinsulationofthebuildingshallmeettherequirementsofsafety,durabilityandprotection.
Theexteriordoorsandwindowsofthebuildingmustbeinstalledfirmly,anditswindloadresistanceperformanceandwatertightnessperformanceshallmeetthefunctionalrequirementsofthebuilding,andadapttothelocalenvironment.
Thefloorofthebathroomandtoiletshallbeprovidedwithawaterprooflayerandtheirwallsandceilingsshallbeprovidedwithamoistureprooflayer.
Passagespacessuchascorridorsandevacuationpassagesshallmeettherequirementsofemergencyevacuationandemergencyrescue,andshallbekeptunblocked.
Thewarningandguidancesignagesystemforsafetyprotectionshallbeinstalledinthebuilding.
4.2ScoringItems
ⅠSafety
Theadoptionofperformance-basedseismicdesignandtherationalimprovementoftheseismicperformanceofthebuildingaretotallyscored10points.
Takeprotectivemeasurestoensurepeople'ssafety,whichisrespectivelyscoredandaccumulatedaccordingtothefollowingcriteria,totally12points:
1Takemeasurestoimprovetheprotectionlevelofbalcony,exteriorwindow,windowsill,balustrade,etc.,whichisscored4points;
2Buildingentrancesandexitsareprovidedprotectivemeasuresforaccidentalfalloutofexternalwalldecorationsaswellastheglazingofdoorsandwindows,andtheprotectivemeasuresarecombinedwithsunshade,windorrainprotectionfacilitiesintheareaopentopeople,whichisscored4points;
3Usethesiteorlandscapetoformabufferzoneandisolationzonethatcanreducetheriskoffallingobjects,whichisscored4points.
Useproductsoraccessorieswithsafetyprotection,whichisrespectivelyscoredandaccumulatedaccordingtothefollowingcriteria,totally10points:
1Useglasseswithsafetyprotectionfunction,whichisscored5points;
2Usedoorsandwindowswithanti-pinchfunction,whichisscored5points.
Takeanti-slipmeasuresforindoorandoutdoorfloorsorroadsurfaces,whichisrespectivelyscoredandaccumulatedaccordingtothefollowingcriteria,totally9points:
1Takeanti-slipmeasuresforbuildingentrancesandexits,platforms,publiccorridors,elevatorhalls,kitchens,bathrooms,toilets,etc.,theanti-skidlevelshallnotbelowerthanBdandBwinTable4.2.4-1and4.2.4-2,whichisscored3points;
2Asforanti-slipgroundforindoorandoutdooractivities,theanti-sliplevelreachesAdandAwlevelinTable4.2.4-1and4.2.4-2,whichisscored3points;
3Theanti-sliplevelofconstructionrampsandstairstepsreachesAdandAwinTable4.2.4-1and4.2.4-2,orisonelevelhigherthanthelevelground,andanti-slipconstructiontechnologymeasuressuchastheuseofanti-slipbars,whichisscored3points.
Table4.2.4-1Wetslipresistancevaluesofoutdoorandindoorwetfloors
Anti-sliplevel
Safetydegreeofanti-slip
Anti-slipvalueBPN
Aw
High
BPN≥80
Bw
Mediumtohigh
60≤BPN<80
Cw
Middle
45≤BPN<60
Dw
Low
BPN<45
Table4.2.4-2Staticfrictioncoefficientofindoordryground
Anti-sliplevel
Safetydegreeofanti-slip
StaticfrictioncoefficientCOF
Ad
High
COF≥0.70
Bd
Mediumtohigh
0.60≤COF<0.70
Cd
Middle
0.50≤COF<0.60
Dd
Low
COF<0.50
Separatepedestriansystemfromvehiclesystem,andprovidethewalkingandbicycletransportationsystemwithsufficientlighting,whichisscored5points.
Videosurveillancesystemissetinpublicareas,whichisscored10points.
ⅡDurability
Takemeasurestoimprovethestructuraladaptabilityofbuildings,whichisrelativelyscoredandaccumulatedaccordingtothefollowingcriteria,totally15points:
1Takeageneralopen,flexibleandvariablespacedesign,oradoptmeasuresofvariablebuildingfunction,whichisscored5points;
2Thebuildingstructureisseparatedfromtheconstructionequipmentpipeline,whichisscored5points;
3Adoptlayoutorcontrolmethodsofequipmentfacilitiesthatarecompatiblewithbuildingfunctionsandspatialchanges,whichisscored5points.
Takemeasurestoimprovethedurabilityofbuildingparts,whichisrespectivelyscoredandaccumulatedaccordingtothefollowingcriteria,totally10points:
1Adoptpipes,pipelinesandfittingswithgoodcorrosionresistance,anti-aginganddurability,whichisscored5points;
2Themovablepartsareselectedfromlong-lifeproducts,andthesamelifespanofthepartscombinationisconsidered;whenthepartsofdifferentservicelifeareconnected,thestructureeasytobeseparatelyreplacedandupdatedisadopted,whichisscored5points.
Improvethedurabilityofbuildingstructurematerials,whichisscoredaccordingtothefollowingcriteria,totally10points:
1Designfor100-yeardurability,whichisscored10points.
2Adoptbuildingstructurematerialswithgooddurabilitythatmeetoneofthefollowingconditions,whichisscored10points:
1)Forconcretemembers,increasethethicknessoftheprotectivelayeroftherebarorusehigh-durabilityconcrete;
2)Forsteelmembers,adoptweather-resistantstructuralsteelorweather-resistantanticorrosivecoatings;
3)Forwoodmembers,useanti-corrosivewood,durablewoodordurablewoodproducts.
Rationallyusedurableandeasy-to-maintaindecorativebuildingmaterials,whichisrespectivelyscoredandaccumulatedaccordingtothefollowingcriteria,totally9points:
1Adoptdurableexteriorfinishmaterials,whichisscored3points;
2Adoptdurablewaterproofandsealingmaterials,whichisscored3points;
3Adoptdurableandeasy-to-maintaininteriordecorationmaterials,whichisscored3points.
5HealthandComfort
5.1PrerequisiteItems
Theconcentrationofpollutantssuchasformaldehyde,benzeneandtotalvolatileorganiccompoundsinindoorairshallmeettherequirementsoftherelevantlocalstandards.Smoke-freemanagementinthebuildingshallcomplywithlocalrequirements.
Measuresshallbetakentoavoidtheairandpollutantsinthekitchen,diningroom,printingandcopyingroom,bathroom,undergroundgarageandotherareasfromgoingintootherspaces;theexhaustbackflowofkitchenandbathroomshallbeprevented.
Thesettingofwatersupplyanddrainagesystemshallbeinaccordancewiththefollowingrequirements:
1Theconventionalindicatorsandlimitsofthequalityofdrinkingwatershallmeettherequirementsofrelevantlocalstandards;
2Theregularcleaninganddisinfectionplanforwaterstoragefacilitiessuchaswaterreservoirsandwatertanksshallbeformulatedandimplemented,andthedrinkingwaterstoragefacilitiesshallbecleanedanddisinfectedatleastonceeverysixmonths.
Reasonableplanningandarrangementofsiteandindooracousticenvironmentshallbecarriedout,whichshallbeinaccordancewiththefollowingrequirements:
1Thenoisesourceareasandnoisesensitiveareasintheprojectshallbereasonablyplannedandarranged.
2Thefunctionalareasinthebuildingshallberationallyplannedandarrangedaccordingtotheacousticenvironmentspace.
Thequantityandqualityofbuildinglightingshallmeettherequirementsoflocalstandards.
Measuresshallbetakentoensuretheindoorthermalenvironment.Forbuildingswithcentralheatingandairconditioningsystems,thedesignparametersoftheroomsuchastemperature,humidityandfreshairvolumeshallcomplywiththerelevantrequirementsofthelocalstandards.
Thethermalperformanceofthebuildingenvelopeshallmeetthefollowingrequirements:
1Undertheconditionofindoordesigntemperatureandhumidity,dewshallnotappearontheinnersurfaceofthenon-transparentbuildingenvelope;
2Condensationshallnotexistontheroofandtheinsideofexteriorwallsoftheheatingbuilding;
3Complywithrelevantlocalstandardstoavoidoverheatinginsummer.
Themainfunctionroomsshallbeequippedwithathermalenvironmentadjustmentdeviceindependentlycontrolledonsite.
5.2ScoringItems
ⅠIndoorAirQuality
Controltheconcentrationofmainairpollutantsintheroom,whichisrespectivelyscoredandaccumulatedaccordingtothefollowingcriteria,totally10points:
1Theconcentrationofmajorpollutantsis10%lowerthanthelimitstipulatedintherelevantlocalstandards,whichisscored3points;itis20%lowerthanthelimits,whichisscored6points;
2TheannualaverageconcentrationofPM2.5intheroomisnothigherthan15μg/m3,andtheannualaverageconcentrationofPM10intheroomisnothigherthan30μg/m3,whichisscored4points.
ThedesignminimumfreshairvolumeintheroomcomplieswiththecalculationresultofEq.(5.2.2),whichisscored5points.
qtot=n×qp+A×qb(5.2.2)
Where:qtot——thetotalventilationrateforthebreathingzone,L/s;
n——thedesignvalueforthenumberofthepersonsintheroom;
qp——theventilationrateforoccupancyperperson,L/(s·person);
A——thefloorarea,m2;
qb——theventilationrateforemissionsfrombuilding,L/(s·m2).
Table5.2.2-1DesignVentilationRatesforPersonsforDifferentCategories
Category
Expectedpercentagedissatisfied
(%)
Airflowperperson
[L/(s·person)]
Ι
15
10
Π
20
7
Ш
30
4
Ⅳ
40
2.5
Table5.2.2-2DesignVentilationRatesforDilutingEmissionsof
DifferentTypeofBuildings
Category
Verylowpollutingbuilding
[L/(s·m2)]
Lowpollutingbuilding
[L/(s·m2)]
Nonlowpollutingbuilding
[L/(s·m2)]
Ι
0.5
1.0
2.0
Π
0.35
0.7
1.4
Ш
0.2
0.4
0.8
Ⅳ
0.15
0.3
0.6
Theundergroundgarageshallbeequippedwithacarbonmonoxideconcentrationmonitoringdevicelinkedtotheexhaustequipment,whichisscored8points.
ⅡWaterQuality
Thewaterqualityoffinedrinkingwater,centraldomestichotwater,swimmingpoolwater,etc.meettherequirementsstipulatedintherelevantlocalstandards,whichisscored8points.
Measuresaretakenforwaterstoragefacilitiessuchasdrinkingwaterreservoirsandwatertankstomeetthehygienerequirements,whichisrespectivelyscoredandaccumulatedaccordingthefollowingcriteria,totally9points:
1Usethefinishedproductwatertankthatmeetstherequirementsstipulatedintherelevantlocalstandards,whichisscored5points;
2Takemeasurestoensurethatthestoredwaterdoesnotdeteriorate,whichisscored4points.
Allwatersupplyanddrainagepipes,equipmentandfacilitiesareprovidedwithdefinite,clearandpermanentmarks,whichisscored8points.
ⅢSoundandDaylighting
Theindoornoiselevelofthemainfunctionalroomisbetterthanthelimitoftherelevantlocalstandards,whichisscoredaccordingtothefollowingcriteria,totally8points:
1Theindoornoiselevelofthemainfunctionalroomis3dBlowerthanthecurrentlocalstandardlimit,ormeetthegoodstandardlimitstipulateintable5.2.7,whichisscored4points;
2Theindoornoiselevelofthemainfunctionalroomis5dBlowerthanthecurrentlocalstandardlimit,ormeetthebeststandardlimitstipulateintable5.2.7,whichisscored8points.
Table5.2.7StandardLimitofIndoorNoiseLevel
Mainfunctionroom
Goodstandardlimit
Beststandardlimit
Residentialbuilding
Bedroom
≤32dB,LAeq,T(nighttime)
≤30dB,LAeq,T(nighttime)
Livingroom
≤37dB,LAeq,T
≤35dB,LAeq,T
School
buildings
Commonclassroom、Laboratory、MultimediaClassroom、Danceroom
≤42dB,LAeq,T
≤40dB,LAeq,T
Languageclassroom、Readingroom、Musicclassroom、Pianoroom
≤37dB,LAeq,T
≤35dB,LAeq,T
Hospital
buildings
Ward、Medicalstaffdutyroom、ICU
≤32dB,LAeq,T(nighttime)
≤30dB,LAeq,T(nighttime)
Clinic、Operatingroom、Deliveryroom、Laboratory、Analyticallaboratory
≤37dB,LAeq,T
≤35dB,LAeq,T
Cleanoperatingroom
≤42dB,LAeq,T
≤40dB,LAeq,T
Artificialreproductioncenterpurificationarea
≤37dB,LAeq,T
≤35dB,LAeq,T
Entrancehall、Waitingroom
≤52dB,LAeq,T
≤50dB,LAeq,T
Hotel
buildings
Guestroom
≤32dB,LAeq,T(nighttime)
≤30dB,LAeq,T(nighttime
Office、Meetingroom、Multipurposehall
≤37dB,LAeq,T
≤35dB,LAeq,T
Dinningroom、Ballroom、Hotellobby
≤45dB,LAeq,T
≤43dB,LAeq,T
Officebuildings
Singleoffice
≤37dB,LAeq,T
≤35dB,LAeq,T
Multi-personoffice、Meetingroom
≤42dB,LAeq,T
≤40dB,LAeq,T
Commercialbuildings
Shoppingmall、Store、Shoppingcenter、ExhibitionCenter
≤52dB,LAeq,T
≤50dB,LAeq,T
Restaurant
≤50dB,LAeq,T
≤45dB,LAeq,T
Stafflounge
≤42dB,LAeq,T
≤40dB,LAeq,T
Thesoundinsulationperformanceofthemainfunctionalroomsisbetterthantherelevantlocalstandards,whichisrespectivelyscoredandaccumulatedaccordingtothefollowingcriteria,totally10points:
1Theairsoundinsulationperformancebetweenroomsis2dBbetterthanthecurrentlocalstandardlimit,ormeetthegoodstandardlimitintable5.2.8-1,whichisscored3points;5dBbetterthanthecurrentlocalstandardlimit,ormeetthebeststandardlimitintable5.2.8-1,whichisscored5points;
2Theimpactsoundinsulationperformanceofthefloorslabis2dBbetterthanthecurrentlocalstandardlimit,ormeetthegoodstandardlimitintable5.2.8-2,whichisscored3points;5dBbetterthanthecurrentlocalstandardlimit,ormeetthebeststandardlimitintable5.2.8-2,whichisscored5points;
Table5.2.8-1StandardLimitsforAirborneSoundInsulationPerformance
betweenRooms
Buildingtype
Component/Room
Goodstandardlimit
Beststandardlimit
Residentialbuildings
Betweenbedroomandneighboringroom
DnT,w+C≥52dB
DnT,w+C≥55dB
Betweenlivingroomandneighboringroom
DnT,w+C≥50dB
DnT,w+C≥53dB
Bedroomwithwindowonexteriorwall
D2m,nT,w+Ctr≥37dB
D2m,nT,w+Ctr≥40dB
School
buildings
Betweencommonclassrooms
DnT,w+C≥47dB
DnT,w+C≥50dB
Betweenlanguageclassrooms,readingroomsandadjacentrooms
DnT,w+C≥52dB
—
Hospital
buildings
Betweenwards
DnT,w+C≥47dB
DnT,w+C≥50dB
Betweenclinics
DnT,w+C≥42dB
DnT,w+C≥45dB
Hotel
buildings
Betweenrooms
DnT,w+C≥50dB
DnT,w+C≥53dB
Guestroomwithwindowonexteriorwallandglasscurtainwall
D2m,nT,w+Ctr≥37dB
D2m,nT,w+Ctr≥40dB
Office
buildings
Betweenoffices,meetingroomsandcommonrooms
DnT,w+C≥47dB
DnT,w+C≥50dB
Commercialbuildings
Betweenfitnesscenters,entertainmentvenues,etc.andnoise-sensitiverooms
DnT,w+Ctr≥57dB
DnTw+Ctr≥60dB
Betweenshoppingcenters,restaurants,conventioncenters,etc.andnoise-sensitiverooms
DnT,w+Ctr≥47dB
DnTw+Ctr≥50dB
Table5.2.8-2StandardLimitofFloorImpactSoundInsulationPerformance
Buildingtype
Floorposition
Goodstandardlimit
Beststandardlimit
Residentialbuildings
Householdfloorofbedroomand
livingroom
L’nT,w≤62dB
L’nT,w≤60dB
School
buildings
Floorslabsbetweenspeechclassroom,readingroomandupperroom
L’nT,w≤62dB
L’nT,w≤60dB
Floorbetweencommonclassrooms
L’nT,w≤67dB
L’nT,w≤65dB
Hospital
buildings
Floorslabsbetweenwards,operatingtheatresandupperrooms
L’nT,w≤67dB
L’nT,w≤65dB
Hotel
buildings
Floorslabsbetweenguestroomandupperroom
L’nT,w≤62dB
L’nT,w≤60dB
Office
buildings
Floorslabsontopofoffices,meetingrooms
L’nT,w≤67dB
L’nT,w≤65dB
Commercialbuildings
Floorslabsbetweenfitnesscenters,entertainmentvenues,etc.andnoise-sensitiverooms
L’nT,w≤47dB
L’nT,w≤45dB
Makefulluseofdaylighting,whichisrespectivelyscoredandaccumulatedaccordingtothefollowingcriteria,totally9points:
1Asforatleast60%areaofmainfunctionalspacesoftheresidentialbuilding.itsaveragenumberofhourswithandaylightingilluminancevalueofnotlessthan300lxisnotlessthan8h/d,whichisscored9points;
2Publicbuildingsarerespectivelyscoredandaccumulatedaccordingtothefollowingcriteria:
1)Thearearatiooftheinnerareadaylightfactormeetingthedaylightingrequirementsis60%,whichisscored3points;
2)Theratiooftheareaoftheundergroundspacewithanaveragedaylightfactorofnotlessthan0.5%totheareaofthefirstbasementfloorismorethan10%,whichisscored3points;
3)Thehoursofatleast60%floorareaoftheindoormainfunctionalspaceswithrequireddaylightingilluminancevalueisnotlessthan4h/d,whichisscored3points.
3Themainfunctionroomshasglarecontrolmeasures,whichisscored3points.
ⅣIndoorThermalEnvironment
Indoorthermalandhumidenvironmentisfavorable,whichisscoredaccordingtothefollowingcriteria,totally8points:
1Forbuildingswithnaturalventilationorhybridventilation,thetimeratioofindoorthermalenvironmentparametersinthemainfunctionalroomsofthebuildingtotheadaptivethermalcomfortzonereaches30%,whichisscored2points;foreachadditional10%,1pointisadded,atmost8points;
2Forthebuildingwithartificialcoldandheatsources,60%ofthemainfunctionroomsarethermallycomfortabletomeettherequirementsinTable5.2.10,whichisscored5points;foreachadditional10%,1pointisadded,atmost8points.
Table5.2.10RequirementsofThermalComfort
Thermalstateofthebody
asawhole
Localdiscomfort
PMV
PPD(%)
DR(%)
PD(%)causedby
verticalairtemperaturedifference
Cwarmorcoolfloor
Rradiantasymmetry
-0.7<PMV<0.7
<15
<30
<10
<15
<10
Optimizethebuildingspaceandplanelayout,improvethenaturalventilationeffect,whichisscoredaccordingtothefollowingcriteria,totally8points:
1Residentialbuildings:theratiooftheventilationopeningareatotheroomfloorareareaches10%inthetropicalareas,and5%inotherareas,whichisscored5points;foreachadditional2%,1pointisadded,atmost8points;
2Non-residentialbuildings:Thelocationoftheairsupplyandexhaustventsshallconsiderthedepth(W:m)andheight(H:m)oftheroom,andmeettherequirementsinTable5.2.11,whichisscored8points.
Table5.2.11NaturalVentilationStrategiesforNon-residentialBuildings
Ventform
RatioofroomdepthtofloorandceilingheightW/H
Aventononesideofthefa?ade
W/H≤2
Twoventononesideofthefa?ade
W/H≤2.5
Oneventoneachoftheoppositefa?ades
W/H≤5
Theadjustableshadingfacilitiesaresettoimprovetheindoorthermalcomfort,whichisscoredaccordingtotheproportionoftheadjustableshadeareatothetransparentpartoftheexteriorwindowandthecriteriaspecifiedinTable5.2.12,totally9points.
Table5.2.12ScoringCriteriafortheProportionoftheAreaofAdjustableShadingFacilitiesintheTransparentPartoftheExteriorWindow
Proportionoftheareaofadjustableshadingfacilitiesinthetransparentpartoftheexteriorwindow,SZ
Score(Points)
25%≤SZ<35%
3
35%≤SZ<45%
5
45%≤SZ<55%
7
SZ≥55%
9
6OccupantConvenience
6.1PrerequisiteItems
Accessiblebarrier-freewalkingsystemshallbeprovidedbetweenbuildings,outdoorsites,publicgreenspacesandurbanroads.
Theparkinglotshallbeequippedwiththechargingfacilitiesofnewenergyvehicleortheinstallationconditionsofthecharg
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 連云港做實“一帶一路交匯點”建設(shè)的對策思考
- 公司財務(wù)知識分享
- 基于生物信息學(xué)探索妊娠期糖尿病與尿苷代謝相關(guān)的關(guān)鍵基因
- 《駱駝祥子》 上課課件
- 科創(chuàng)孵化器項目融資報告
- 建立強大的醫(yī)院管理團隊
- 光伏組件回收產(chǎn)業(yè)前景分析報告
- 二零二五年度個人借款擔(dān)保機構(gòu)合作協(xié)議3篇
- 2025版蓄水池安全監(jiān)測系統(tǒng)設(shè)計與安裝服務(wù)合同范本3篇
- 質(zhì)子治療設(shè)備安裝方案
- 數(shù)學(xué)-山東省2025年1月濟南市高三期末學(xué)習(xí)質(zhì)量檢測濟南期末試題和答案
- 移動商務(wù)內(nèi)容運營(吳洪貴)任務(wù)一 移動商務(wù)內(nèi)容運營關(guān)鍵要素分解
- 基于ADAMS的汽車懸架系統(tǒng)建模與優(yōu)化
- 當(dāng)前中國個人極端暴力犯罪個案研究
- 中國象棋比賽規(guī)則
- 7天減肥餐食譜給你最能瘦的一周減肥食譜
- GB/T 31525-2015圖形標(biāo)志電動汽車充換電設(shè)施標(biāo)志
- 最新北師大版八年級數(shù)學(xué)下冊教學(xué)課件全冊
- 裝飾業(yè)務(wù)員培訓(xùn)教程方案
- 2022年五年級解方程小數(shù)和分?jǐn)?shù)計算題
- 海淀區(qū)重點中學(xué)初中英語新課標(biāo)1600詞匯表
評論
0/150
提交評論