2022建筑同層排水工程技術(shù)標(biāo)準(zhǔn)_第1頁
2022建筑同層排水工程技術(shù)標(biāo)準(zhǔn)_第2頁
2022建筑同層排水工程技術(shù)標(biāo)準(zhǔn)_第3頁
2022建筑同層排水工程技術(shù)標(biāo)準(zhǔn)_第4頁
2022建筑同層排水工程技術(shù)標(biāo)準(zhǔn)_第5頁
已閱讀5頁,還剩45頁未讀, 繼續(xù)免費(fèi)閱讀

下載本文檔

版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進(jìn)行舉報(bào)或認(rèn)領(lǐng)

文檔簡介

建筑同層排水工程技術(shù)標(biāo)準(zhǔn)目 次總則 1術(shù)語 2設(shè)計(jì) 3一般規(guī)定 3地面敷設(shè)方式 4沿墻敷設(shè)方式 6管道布置和敷設(shè) 8水力計(jì)算 9管材和接口 124 施工 14一般規(guī)定 14施工準(zhǔn)備 14管道安裝 16隱蔽式支架安裝 195 驗(yàn)收 20一般規(guī)定 20驗(yàn)收要求 20工程竣工驗(yàn)收 216 維護(hù) 22附錄A不降板同層排水管道安裝示意圖 23附錄B 降板同層排水管道安裝示意圖 24附錄C 沿墻敷設(shè)同層排水管道安裝及排水管穿樓板示意圖 25附錄D 建筑排水高密度聚乙烯管水力計(jì)算表 26附錄E 建筑排水硬聚氯乙烯管水力計(jì)算表 28附錄F 建筑排水柔性接口鑄鐵管水力計(jì)算表 30本標(biāo)準(zhǔn)用詞說明 32引用標(biāo)準(zhǔn)名錄 33條文說明 35PAGEPAGE13PAGEPAGE10總 則技術(shù)先進(jìn)、安全衛(wèi)生、經(jīng)濟(jì)合理并確保質(zhì)量,制定本標(biāo)準(zhǔn)。工程的設(shè)計(jì)、施工、驗(yàn)收及維護(hù)。同層排水工程所采用的衛(wèi)生器具及配件、地漏和管材(件等產(chǎn)品規(guī)格尺寸及主要性能指標(biāo)均應(yīng)符合現(xiàn)行國家標(biāo)準(zhǔn)的有關(guān)規(guī)定,且應(yīng)符合本標(biāo)準(zhǔn)的有關(guān)要求。術(shù) 語同層排水same-floordrainage建筑排水系統(tǒng)中,器具排水管和排水橫支管不穿越本層結(jié)構(gòu)樓板到下層空間,且與衛(wèi)生器具同層敷設(shè)并接入排水立管的排水方式。地面敷設(shè)slabpipeinstallation面之間,與排水立管相連的同層排水敷設(shè)方式。沿墻敷設(shè)wallpipeinstallation器具排水管和排水橫支管敷設(shè)在本層樓板上方非承重墻(或裝飾墻)內(nèi)或明裝在墻體外,與排水立管相連的同層排水敷設(shè)方式。隱蔽式支架concealedsupport用于固定壁掛式洗臉盆、壁掛式小便斗、壁掛式坐便器及沖洗水箱等衛(wèi)生器具的專用安裝支架,隱蔽安裝在裝飾墻內(nèi)。降板同層排水thesamefloordrainagesystemfallingplate建筑衛(wèi)生間結(jié)構(gòu)樓板下沉(或局部下沉),器具排水橫支管敷設(shè)在下沉空間內(nèi)的同層敷設(shè)排水方式。不降板同層排水thesamefloordrainagesystemwithoutfallingplate建筑衛(wèi)生間結(jié)構(gòu)樓板不降低,器具排水橫支管與衛(wèi)生間器具同層敷設(shè)的排水方式。積水排除系統(tǒng)waterdrainsystem在低于排水立管根部的最低位置完全排除建筑結(jié)構(gòu)樓板防水層上的積水,并且使系統(tǒng)部件能夠與防水層的防水材料進(jìn)行系統(tǒng)性一體化的防水層收口的系統(tǒng)。設(shè) 計(jì)一般規(guī)定具布置等,應(yīng)與建筑、結(jié)構(gòu)和機(jī)電各專業(yè)協(xié)調(diào)后確定。置和衛(wèi)生器具布置,沿墻敷設(shè)和地面敷設(shè)可結(jié)合使用。同層排水的器具排水管和排水橫支管應(yīng)與衛(wèi)生器具同層敷設(shè),不得穿越結(jié)構(gòu)樓板進(jìn)入下層空間。排水立管、通氣立管可穿越結(jié)構(gòu)樓板。和安全產(chǎn)生不利影響。住宅衛(wèi)生間宜采用不降板同層排水。管材及管件等應(yīng)根據(jù)敷設(shè)方式選擇并配套使用。水型用水器具。GB26730和《建筑同層排水部件》CJ/T363的有關(guān)規(guī)定。(內(nèi)置存水彎且易于清通,GB50015186的有關(guān)規(guī)定。同層排水工程中的地漏,宜選用地漏主體結(jié)構(gòu)有防水層收口,且與防水層有可靠連接的形式。同層排水工程中,水封設(shè)置應(yīng)符合下列規(guī)定:以下設(shè)置存水彎;50mm,嚴(yán)禁采用活動(dòng)機(jī)械活瓣替代水封,嚴(yán)禁采用鐘式結(jié)構(gòu)地漏。800mm采用同層排水時(shí),連接同層排水橫支管的排水立管不宜偏置。當(dāng)受條件限制必須偏置時(shí),宜根據(jù)排水立管的特點(diǎn)和相應(yīng)的規(guī)定,采取防止堵塞的技術(shù)措施。地面敷設(shè)方式AB。地面敷設(shè)的降板高度(或抬高建筑面層時(shí),結(jié)構(gòu)樓板至建筑面層的凈空高度)應(yīng)根據(jù)衛(wèi)生器具的型式及布置、降板區(qū)域、管徑地面敷設(shè)時(shí),地漏宜采用具有檢修功能的多通道地漏。3.1.12的要求,且不得形成滿管流排水狀態(tài)。及填充層內(nèi)填充材料,應(yīng)由建筑專業(yè)確定。敷設(shè)在填充層中的排水管道,不宜采用橡膠圈密封接口。域內(nèi)不應(yīng)設(shè)置管道接口。要求外,尚應(yīng)符合下列規(guī)定:管道穿越有防水要求的墻體、樓板時(shí),應(yīng)采取防滲漏措施;采用降板結(jié)構(gòu)(或建筑面層抬高)成地面均應(yīng)設(shè)置防水層;衛(wèi)生器具的安裝不應(yīng)破壞地面防水層;降板空間(或抬高空間)凝土;填充層面應(yīng)整澆,并應(yīng)采取措施防止開裂;(或抬高空間降板區(qū)域(或建筑面層抬高區(qū)域)排水管道的安裝應(yīng)在結(jié)構(gòu)降板區(qū)域(或建筑面層抬高區(qū)域)水封,且應(yīng)具有防干涸和防返溢功能。噪聲的措施:1排水主要配件與樓板固定處襯墊消聲層;排水管道與管道支架接觸部位襯墊消聲材料;墻體裝飾材料與衛(wèi)生器具支架結(jié)合面襯墊消聲層;2cm~5cm。沿墻敷設(shè)方式C,并應(yīng)符合下列規(guī)定:或相鄰墻面敷設(shè);大便器宜靠近排水立管布置;入立管。沿墻敷設(shè)的衛(wèi)生器具應(yīng)符合下列規(guī)定:式?jīng)_洗水箱;凈身盆和小便器應(yīng)采用后排水式,并宜采用壁掛式;置水封的直埋式地漏。支架應(yīng)有足夠的強(qiáng)度、剛度,并應(yīng)采取防腐措施;支架上;結(jié)構(gòu)上。管道時(shí),應(yīng)符合下列規(guī)定:非承重墻或裝飾墻的墻體厚度或空間應(yīng)滿足排水管道和附件用粘貼;采取防水防潮措施。道不宜穿越承重墻。其建筑地面面層厚度應(yīng)滿足地漏的安裝要求。設(shè)置壁掛式坐便器的附加隔墻厚度應(yīng)根據(jù)隱蔽式水箱、排水180mm~200mm850mm1200mm。噪聲的措施:墻體裝飾材料與衛(wèi)生器具支架結(jié)合面襯墊消聲層;板;采用建筑排水高密度聚乙烯管材及管件;2cm~5cm。管道布置和敷設(shè)或架空樓板內(nèi)暗設(shè),且應(yīng)便于安裝。45(采用45°斜三通或彎頭)。設(shè)計(jì)標(biāo)準(zhǔn)》GB50015采取防水和防火措施。4545°斜三通接入。9045排水橫支管和橫干管的管道變徑處,應(yīng)管頂平接。45°斜三通或順?biāo)?。建筑排水塑料管?yīng)按現(xiàn)行行業(yè)標(biāo)準(zhǔn)《建筑排水塑料管道工程技術(shù)規(guī)程》CJJ/T29的有關(guān)規(guī)定設(shè)置伸縮節(jié)。管道在非承重墻、裝層內(nèi)敷設(shè)時(shí)不應(yīng)設(shè)置伸縮節(jié)。在非承重墻、裝飾墻或架空地面的空間內(nèi)敷設(shè)排水橫支管時(shí),支架(或支墩)的設(shè)置應(yīng)符合下列規(guī)定:(或支墩的間距應(yīng)符合表3.4.10的規(guī)定;熱熔連接或粘接的管道應(yīng)采用固定支架;采用建筑排水柔性接口鑄鐵管時(shí),支架(或支墩)應(yīng)設(shè)置在300mm2m;變化引起的膨脹力。表3.4.10采用建筑排水塑料管時(shí),支架(或支墩)的間距管道公稱外徑(mm)32405056637590110125160立管(m)1.201.201.201.501.501.502.002.002.002.50橫管(m)0.500.500.500.750.750.751.001.101.301.60當(dāng)管道穿越防火墻時(shí)應(yīng)在墻兩側(cè)管道上設(shè)置;dn110mm明設(shè)的排水立管穿越樓板處;dn110mm橫支管穿越置。通氣管的設(shè)置應(yīng)符合現(xiàn)行國家標(biāo)準(zhǔn)《建筑給水排水設(shè)計(jì)標(biāo)準(zhǔn)》GB50015的有關(guān)規(guī)定。水力計(jì)算衛(wèi)生器具的排水流量、當(dāng)量、排水設(shè)計(jì)秒流量和排水管管徑GB50015的有關(guān)規(guī)定。排水橫管的水力計(jì)算應(yīng)按下列公式計(jì)算:qpAvv1R2/3I1/2n式中:qp——計(jì)算管段排水設(shè)計(jì)秒流量(L/s);

(3.5.2-1)(3.5.2-2)A——管道在設(shè)計(jì)充滿度的過水?dāng)嗝娣e(m2);v——流速(m/s);n——粗糙系數(shù),鑄鐵管為0.013,塑料管為0.009;R——水力半徑(m);I——水力坡度,采用排水管道坡度。排水橫管內(nèi)在設(shè)計(jì)充滿度下的最小設(shè)計(jì)流速應(yīng)符合下列規(guī)定:當(dāng)排水橫管管徑小于等于150mm時(shí),設(shè)計(jì)流速不應(yīng)小于0.65m/s;當(dāng)排水橫管管徑大于等于200mm時(shí),設(shè)計(jì)流速不應(yīng)小于0.70m/s。3.5.6-13.5.6-2的最大設(shè)計(jì)充滿度。管的通用坡度、最小坡度和最大設(shè)計(jì)充滿度,宜按表3.5.6-1、表3.5.6-2確定。管道公稱直徑DN(mm管道公稱直徑DN(mm)通用坡度最小坡度最大設(shè)計(jì)充滿度h/d500.0350.0250.5750.0250.0151000.0200.0121250.0150.0101500.0100.0070.62000.0080.005表3.5.6-2建筑排水塑料管排水橫管的通用坡度、最小坡度和最大設(shè)計(jì)充滿度管道公稱外徑(mm)通用坡度最小坡度最大設(shè)計(jì)充滿度h/d500.0250.01200.5750.0150.00701100.0120.00401250.0100.00351600.0070.00300.6≥2000.0050.0030DEF確定。排水設(shè)計(jì)標(biāo)準(zhǔn)》GB50015的有關(guān)規(guī)定確定。3.6 管材和接口求。水用柔性接口機(jī)制鑄鐵管材等。求。熔連接方式。建筑排水塑料管和管件應(yīng)符合下列規(guī)定:(PVC-U)GB/T5836.1(PVC-U)GB/T5836.2VC-UGT160(HDPE)CJ/T250CJJ/T29的有關(guān)規(guī)定;插粘接、橡膠密封圈連接或熱熔連接;料管道工程技術(shù)規(guī)程》CJJ/T29的有關(guān)規(guī)定。建筑排水柔性接口鑄鐵管和管件應(yīng)符合下列規(guī)定:管材、管件和附件應(yīng)符合現(xiàn)行國家標(biāo)準(zhǔn)《排水用柔性接口鑄鐵管、管件及附件》GB/T12772、《建筑排水用柔性接口承插式鑄CJ/T178CJ/T177的有關(guān)規(guī)定。管材、管件應(yīng)配套使用;管材和管件的內(nèi)外表面應(yīng)涂防腐涂料;腐涂料應(yīng)與管材外壁涂料一致;蝕表面處理。暗裝時(shí)應(yīng)采用相應(yīng)防腐措施或不銹鋼材質(zhì);卡箍式接口用卡箍件及緊固件的材質(zhì)應(yīng)符合現(xiàn)行國家標(biāo)準(zhǔn)《排水用柔性接口鑄鐵管、管件及附件》GB/T12772的有關(guān)規(guī)定。暗裝時(shí)卡箍件和緊固件應(yīng)采取相應(yīng)的防腐措施且不得用于埋地敷設(shè);法蘭承插式接口用橡膠密封圈、卡箍式接口用鋼帶型卡箍橡膠密封封套和橡膠密封材料應(yīng)采用三元乙丙(EPDM)、氯丁、丁腈、丁苯等,不得含有再生橡膠及有害雜質(zhì),并應(yīng)符合現(xiàn)行國家標(biāo)GB/T2187360±5插式接口用橡膠密封圈應(yīng)采用三元乙丙(EPDM);屬管道工程技術(shù)規(guī)程》CJJ127的有關(guān)規(guī)定。同層排水工程采用特殊單立管時(shí),其管材、管件及附件等應(yīng)連接,應(yīng)采用專用配件或采取保證可靠連接的技術(shù)措施。施 工一般規(guī)定施工單位應(yīng)按批準(zhǔn)的設(shè)計(jì)文件和施工組織設(shè)計(jì)進(jìn)行施工安裝,不得擅自修改工程設(shè)計(jì)。和主要配件應(yīng)采取保護(hù)措施。材料、人工、機(jī)具、水、電等應(yīng)準(zhǔn)備就緒。檢驗(yàn)。性能,掌握操作要點(diǎn)和安全生產(chǎn)規(guī)定。進(jìn)行填充層的施工。墻體支架、樓板支架與設(shè)施的安裝及管線敷設(shè)不應(yīng)破壞防水層。施工準(zhǔn)備同層排水工程施工前應(yīng)具備下列條件:施工圖紙及其他技術(shù)文件應(yīng)齊全;應(yīng)具有批準(zhǔn)的施工組織設(shè)計(jì),并已完成技術(shù)交底;應(yīng)按設(shè)計(jì)圖紙配合土建預(yù)留孔、洞;樓板防水施工應(yīng)驗(yàn)收合格。材料驗(yàn)收應(yīng)符合下列規(guī)定:缺陷。管材端面應(yīng)平整,且應(yīng)與軸線垂直;的氣候條件;阻火圈或阻火膠帶應(yīng)標(biāo)有規(guī)格、耐火極限和生產(chǎn)廠名稱。材料貯運(yùn)應(yīng)符合下列規(guī)定:摔、拖;管材和管件應(yīng)分類堆放。管材應(yīng)水平堆放在平整的場地上,1.5m(袋2.0m;遠(yuǎn)離明火、熱源;領(lǐng)、禁止明火。管道安裝3章的有關(guān)規(guī)定和設(shè)計(jì)文件要求。同層排水工程的管道安裝應(yīng)按下列程序進(jìn)行:土建工程已完成樓板面或地面防水工程;測定位和配管;按水流順序?qū)艿馈⒐芗?、附件進(jìn)行預(yù)制或組裝;不得損壞已完成的土建防水工程;板面的施工,且施工過程不得損壞已安裝好的管道。建筑排水高密度聚乙烯管安裝應(yīng)符合下列規(guī)定:管道切割應(yīng)采用機(jī)切割,切口應(yīng)垂直于管中心;切割面應(yīng)保持清潔,不得與其他物體接觸;2mm;0.3。建筑排水硬聚氯乙烯管安裝應(yīng)符合下列規(guī)定:應(yīng)采用承插粘接連接;管道接口連接前,應(yīng)將管材與管件承口試插一次;涂抹粘接劑時(shí),應(yīng)清除粘接表面的灰塵、水跡、油污等;粘接完畢后,應(yīng)擦凈接口處多余的粘接劑;夏季施工不宜采用中型或重型的膠粘劑。冬季環(huán)境溫度低于﹣10℃施工,不宜采用粘接連接。建筑排水柔性接口鑄鐵管的安裝應(yīng)符合下列規(guī)定:應(yīng)采用承插式連接或卡箍式連接;連接前應(yīng)先清除連接部位的瀝青、砂、毛刺等雜物;栓;鋼節(jié)套內(nèi),然后擰緊節(jié)套上的螺栓;暗裝在裝飾墻或管道井(或管窿)刷防腐涂料、瀝青漆等防腐措施;20mm。面上安裝牢固,不得將其重量和承載的荷載作用在管道上。管道支架的安裝應(yīng)符合下列規(guī)定:安裝和固定管道用的支架(管卡)貨商配套供應(yīng);墊軟質(zhì)材料;金屬支架應(yīng)采取防腐措施;建筑排水塑料管道的支架間距應(yīng)符合本標(biāo)準(zhǔn)表3.4.10的規(guī)定。3.4.10滑動(dòng)支架。建筑排水高密度聚乙烯排水管應(yīng)全部設(shè)置固定支架。建筑排水柔性接口鑄鐵管支架的安裝應(yīng)符合下列規(guī)定:3m300mm;橫管上每根直管應(yīng)至少安裝一個(gè)支架,支架的間距不應(yīng)大于300mm;排水橫管支架與接入立管或水平管中心線的距離宜為300mm~500mm;12m。橫管平面轉(zhuǎn)彎時(shí),彎頭處應(yīng)增設(shè)固定支架。當(dāng)建筑排水柔性接口鑄鐵管的直線管段局部需要偏轉(zhuǎn)安裝時(shí),接口應(yīng)按軸向(偏轉(zhuǎn)角為零)連接好后再進(jìn)行偏轉(zhuǎn)。法蘭承插5°,卡箍式柔性接口的偏轉(zhuǎn)角度3°。采用膠粘劑連接的管道,伸縮節(jié)的安裝應(yīng)符合下列規(guī)定:建筑排水塑料管道的立管應(yīng)每層安裝一個(gè)伸縮節(jié);上方;道工程技術(shù)規(guī)程》CJJ/T29的有關(guān)規(guī)定;伸縮節(jié)插口應(yīng)順?biāo)鞣较?。隱蔽式支架安裝衛(wèi)生器具支架應(yīng)根據(jù)安裝詳圖在墻上和地面標(biāo)出固定點(diǎn)尺寸,鉆孔安裝膨脹螺栓,固定衛(wèi)生器具支架。安裝壁掛式衛(wèi)生器具的裝飾墻應(yīng)緊貼隱蔽式安裝支架。隱蔽式支架固定在樓板承重結(jié)構(gòu)上時(shí),固定支架的膨脹螺栓不應(yīng)穿透結(jié)構(gòu)樓板,且安裝后應(yīng)采用水泥砂漿對支腳部位現(xiàn)澆凸臺封閉,并應(yīng)進(jìn)行二次防水處理。隱蔽式支架的安裝位置應(yīng)符合設(shè)計(jì)要求,且應(yīng)橫平豎直,固定牢靠。安裝時(shí)應(yīng)使用水平尺進(jìn)行校正。隱蔽式水箱的安裝應(yīng)符合下列規(guī)定:水箱應(yīng)固定在衛(wèi)生器具隱蔽式支架上;水箱安裝高度應(yīng)符合設(shè)計(jì)要求;水箱及配件應(yīng)有檢測報(bào)告。驗(yàn) 收一般規(guī)定同層排水工程質(zhì)量驗(yàn)收應(yīng)按現(xiàn)行國家標(biāo)準(zhǔn)《建筑給水排水及GB5024250300的有關(guān)規(guī)定執(zhí)行。驗(yàn)批的質(zhì)量應(yīng)按主控項(xiàng)目和一般項(xiàng)目進(jìn)行驗(yàn)收。及采暖工程施工質(zhì)量驗(yàn)收規(guī)范》GB50242的有關(guān)規(guī)定。驗(yàn)收要求主控項(xiàng)目的驗(yàn)收應(yīng)符合下列規(guī)定:衛(wèi)生用房的樓板和墻身應(yīng)采取防水措施;管材及管件應(yīng)符合設(shè)計(jì)要求;排水管道坡度應(yīng)符合設(shè)計(jì)要求,排水橫管不得無坡或倒坡;無滲漏;漏;腐良好,固定方式不應(yīng)破壞建筑防水層;塑料排水管伸縮節(jié)的安裝位置應(yīng)正確,支架應(yīng)牢固;排水管道穿越樓板部位采取的防滲防漏措施應(yīng)可靠;衛(wèi)生器具的上邊緣;100%;衛(wèi)生器具應(yīng)進(jìn)行滿水試驗(yàn),各連接部件不得滲漏。一般項(xiàng)目的驗(yàn)收應(yīng)符合下列規(guī)定:4.3節(jié)的規(guī)定;15mm,標(biāo)高允許偏差不得大于±15mm1.0mm。GB50242的有關(guān)規(guī)定。工程竣工驗(yàn)收格后進(jìn)行。出竣工驗(yàn)收申請??⒐を?yàn)收時(shí)應(yīng)提交下列文件:設(shè)計(jì)變更文件和竣工圖;格證明文件及安裝說明書;隱蔽工程驗(yàn)收記錄;各分項(xiàng)工程質(zhì)量驗(yàn)收記錄;排水立管及橫干管灌水及通球試驗(yàn)記錄。6 維 護(hù)同層排水工程應(yīng)在竣工驗(yàn)收合格后方可使用。應(yīng)向用戶提供使用說明、維護(hù)文件。同層排水系統(tǒng)的日常檢查和保養(yǎng)應(yīng)包括下列內(nèi)容:衛(wèi)生器具應(yīng)安裝牢靠;衛(wèi)生器具、地漏所設(shè)置的存水彎應(yīng)運(yùn)行正常;污、廢水應(yīng)迅速排放到立管中,排水管道不應(yīng)淤堵;質(zhì)。應(yīng)定期進(jìn)行維護(hù),并應(yīng)做好日常維護(hù)記錄,建立檔案。密。衛(wèi)生器具出水口于排水管道的接入口進(jìn)行疏通。事故的操作,應(yīng)做好安全防護(hù)。附錄A 不板同排水道安示意圖A.0.1 A.0.1。h≥15Φ7~Φ16陶粒層h≥15Φ7~Φ16陶粒層防水層C20細(xì)石混凝土分層嵌實(shí)

地面固定式隱蔽式水箱積水排除管

≥5060水泥砂漿阻水圈高≥5060隔墻(見建筑設(shè)計(jì)) 隔墻(見建筑設(shè)計(jì)) 干硬性混凝土排水橫支管h≥15Φ7~Φ16陶粒區(qū) 防水層(見建筑設(shè)計(jì))h≥151∶3水泥砂漿找平層防反溢HDPE加強(qiáng)型旋流器圖A.0.1不降板同層排水管道安裝示意圖

防水層坡向臺口坡度:無倒坡附錄B 降同層水管安裝意圖接洗臉盆接大便器 接浴盆水泥砂漿固定高水封地漏接洗臉盆接大便器 接浴盆水泥砂漿固定高水封地漏阻水圈防水層支墩水泥陶粒或焦渣填實(shí)防水層C20細(xì)石混凝土裝飾面層H﹣0.02圖B.0.1降板同層排水管道安裝示意圖附錄C沿墻敷設(shè)同層排水管道安裝及排水管穿樓板示意圖6007.8R1/2〞180/230裝飾墻H﹣0.02H﹣0.028.56007.8R1/2〞180/230裝飾墻H﹣0.02H﹣0.028.5~10.582090760水泥砂漿阻水圈裝飾面層防水層防漏環(huán)保護(hù)層防水層水泥砂漿阻水圈裝飾面層防水層防漏環(huán)保護(hù)層防水層防漏環(huán)C20細(xì)石混凝土0~200600~200≥350圖C.0.1-2≥350PAGEPAGE27PAGEPAGE30附錄D 建排水密度乙烯水力算表建筑排水高密度聚乙烯管道橫管(h/d=0.5)的水力計(jì)算見表D.0.1。表D.0.1建筑排水高密度聚乙烯管水力計(jì)算表(h/d=0.5)管道坡度dn50dn56dn63dn75dn90dn110dn125dn160(m/s)(L/s)(m/s)(L/s)(m/s)(L/s)(m/s)(L/s)(m/s)(L/s)(m/s)(L/s)(m/s)(L/s)(m/s)(L/s)0.0040.663.460.786.660.0050.682.740.743.860.877.450.0060.651.760.743.000.814.230.958.160.0070.701.900.803.260.874.571.038.820.0080.661.240.752.030.863.460.934.891.109.420.0090.701.320.802.150.913.690.995.191.1710.000.0100.650.830.741.390.842.270.963.891.055.471.2310.540.0150.670.510.730.720.801.020.911.701.032.781.184.771.286.691.5112.900.0200.780.590.850.830.921.181.051.961.193.211.365.501.487.731.7414.900.0250.870.660.950.931.031.321.172.191.333.591.526.151.658.641.9516.660.0300.950.721.041.021.131.441.282.401.453.931.666.741.819.472.1318.250.0351.030.781.121.101.221.561.392.591.574.251.807.281.9610.232.3019.710.0401.100.841.201.181.311.671.482.771.684.541.927.782.0910.932.4621.070.0451.170.891.271.251.391.771.572.941.784.812.048.262.2211.592.6122.350.0501.230.93l.341.311.461.861.663.101.885.082.158.702.3412.172.7523.560.0551.290.981.401.381.531.951.743.251.975.322.259.132.4512.222.8924.710.0601.351.021.471.441.602.041.823.402.065.562.359.532.5613.393.0225.810.0651.401.071.531.501.672.121.893.542.145.792.459.922.6613.943.1426.860.0701.451.111.581.551.732.201.963.672.226.012.5410.302.7714.463.2627.880.0751.511.141.641.611.792.282.033.802.306.222.6310.652.8514.973.3728.850.0801.551.181.691.661.852.362.103.922.376.422.7211.012.9615.463.4829.80建筑排水高密度聚乙烯管道橫管(h/d=0.6)的水力計(jì)算見表D.0.2。表D.0.2建筑排水高密度聚乙烯管水力計(jì)算表(h/d=0.6)管道坡度dn50dn56dn63dn75dn90dn110dn125dn160(m/s)(L/s)(m/s)(L/s)(m/s)(L/s)(m/s)(L/s)(m/s)(L/s)(m/s)(L/s)(m/s)(L/s)(m/s)(L/s)0.0040.653.310.714.640.848.950.0050.733.700.795.190.9310.010.0060.702.360.804.050.875.691.0210.960.0070.671.560.752.550.864.370.946.141.1011.840.0080.711.670.802.730.924.681.006.571.1812.660.0090.661.060.751.770.852.890.984.961.066.971.2513.430.0100.640.790.701.120.801.860.903.051.035.231.127.341.3214.150.0150.720.690.790.970.861.370.972.281.103.731.266.401.378.991.6217.340.0200.830.790.911.120.991.581.122.641.274.311.457.391.5810.381.8720.020.0250.930.891.011.251.111.771.262.951.424.821.638.271.7711.612.0922.380.0301.020.971.111.371.211.941.383.231.565.281.789.061.9412.722.2924.520.0351.101.051.201.481.312.091.493.491.685.701.939.782.1013.742.4726.480.0401.181.121.281.581.402.241.593.731.806.102.0610.462.2414.692.6428.310.0451.251.191.361.671.492.371.693.951.916.472.1811.092.3815.582.8030.030.050l.321.261.431.761.572.501.784.172.016.822.3011.692.5116.422.9531.650.0551.381.321.501.851.642.631.874.372.117.152.4112.262.6317.223.1033.200.0601.441.371.571.931.722.741.954.562.207.472.5212.812.7517.993.2334.670.0651.501.43l.642.011.792.852.034.752.297.772.6213.332.8618.723.3736.090.0701.561.491.702.091.852.962.104.932.388.072.7213.832.9719.433.4937.450.0751.611.541.762.161.923.072.185.102.468.352.8214.323.0720.113.6238.760.0801.671.591.822.231.983.172.255.272.548.622.9114.793.1720.773.7440.04E建筑排水硬聚氯乙烯管道橫管(h/d=0.5)的水力計(jì)算見表E.0.1。表E.0.1建筑排水硬聚氯乙烯管水力計(jì)算表(h/d=0.5)管道坡度dn50dn75dn90dn110dn125dn160流速(m/s)流量(L/s)流速(m/s)流量(L/s)流速(m/s)流量(L/s)流速(m/s)流量(L/s)流速(m/s)流量(L/s)流速(m/s)流量(L/s)0.0040.673.720.797.210.0050.692.900.754.160.898.060.0060.651.790.753.180.824.550.978.830.0070.711.940.813.430.894.921.059.530.0080.671.310.752.070.873.670.955.261.1210.190.0090.711.390.802.190.923.891.015.581.1910.810.0l00.751.460.842.310.974.101.065.881.2611.390.0150.690.580.921.791.032.831.195.021.307.201.5413.960.0200.800.671.062.071.193.271.385.801.518.311.7816.110.0250.900.741.192.311.333.661.546.481.689.301.9918.020.0300.980.811.302.531.464.011.687.101.8410.182.1819.740.0351.060.881.412.741.584.331.827.671.9911.002.3521.320.0401.130.941.502.931.694.631.958.202.1311.762.5122.790.0451.201.001.593.101.794.912.068.702.2612.472.6624.170.0501.271.051.683.271.895.172.179.172.3813.152.8125.480.055l.331.101.763.431.985.432.289.612.5013.792.9526.720.0601.391.151.843.582.065.672.3810.042.6114.403.0827.910.0651.441.201.923.732.155.902.4810.452.7114.993.2029.050.0701.501.241.993.872.236.122.5710.852.8215.563.3230.150.0751.551.292.064.012.316.342.6611.232.9216.103.4431.210.0801.601.332.134.142.386.542.7511.603.0116.633.5532.23建筑排水硬聚氯乙烯管道橫管(h/d=0.6)的水力計(jì)算見表E.0.2。表E.0.2建筑排水硬聚氯乙烯管水力計(jì)算表(h/d=0.6)管道坡度dn50dn75dn90dn110dn125dn160流速(m/s)流量(L/s)流速(m/s)流量(L/s)流速(m/s)流量(L/s)流速(m/s)流量(L/s)流速(m/s)流量(L/s)流速(m/s)流量(L/s)0.0040.663.480.725.000.859.680.0050.743.890.815.590.9510.820.0060.702.410.814.270.886.121.0411.860.0070.671.640.762.600.874.610.956.611.1312.810.0080.721.760.812.780.934.931.027.071.2013.690.0090.761.860.862.950.995.221.087.491.2814.520.0100.811.970.903.111.045.511.147.901.3515.310.0150.740.770.992.411.113.811.286.751.409.681.6518.750.0200.860.891.142.781.284.401.477.791.6111.171.9021.650.0250.961.001.273.111.434.911.658.711.8012.492.1324.200.0301.051.091.403.401.575.381.819.541.9813.682.3326.510.0351.141.181.513.681.695.821.9510.302.1414.782.5228.640.0401.211.261.613.931.816.222.0911.022.2815.802.6930.620.0451.291.341.714.171.926.592.2111.682.4216.762.8632.470.0501.361.411.804.402.026.952.3312.322.5517.673.0134.230.0551.421.481.894.612.127.292.4512.922.6818.533.1635.900.0601.491.551.974.822.217.612.5513.492.8019.353.3037.500.0651.551.612.065.012.307.932.6614.042.9120.143.4339.030.0701.611.672.135.202.398.222.7614.573.0220.903.5640.500.0751.661.732.215.382.488.512.8615.083.1321.643.6941.920.0801.721.792.285.562.568.792.9515.583.2322.343.8143.30附錄F 建排水性接鑄鐵水力算表建筑排水柔性接口鑄鐵管道橫管(h/d=0.5)的水力計(jì)算見表F.0.1。表F.0.1建筑排水柔性接口鑄鐵管水力計(jì)算表(h/d=0.5)管道坡度DN50DN75DN100DN125DN150流速(m/s)流量(L/s)流速(m/s)流量(L/s)流速(m/s)流量(L/s)流速(m/s)流量(L/s)流速(m/s)流量(L/s)0.0070.726.370.0080.776.810.0090.827.220.0100.764.680.867.610.0150.661.470.813.160.935.741.069.320.0200.771.700.933.651.086.621.2210.760.0250.660.640.861.901.044.081.217.401.3612.030.0300.720.700.942.081.144.471.328.111.4913.180.0350.780.761.022.241.234.831.438.761.6114.240.0400.830.811.092.401.325.171.539.371.7215.220.0450.880.861.152.541.405.481.629.931.8316.150.0500.930.911.212.681.475.781.7110.471.9317.020.0550.970.951.272.811.546.061.7910.982.0217.850.0601.011.001.332.941.616.331.8711.472.1118.640.0651.061.041.383.061.686.581.9511.942.2019.400.0701.101.081.443.171.746.832.0212.392.2820.140.0751.131.111.493.281.807.072.0912.822.3620.840.0801.171.151.543.391.867.312.1613.242.4421.53建筑排水柔性接口鑄鐵管道橫管(h/d=0.6)的水力計(jì)算見表F.0.2。表F.0.2建筑排水柔性接口鑄鐵管水力計(jì)算表(h/d=0.6)管道坡度DN50DN75DN100DN125DN150流速(m/s)流量(L/s)流速(m/s)流量(L/s)流速(m/s)流量(L/s)流速(m/s)流量(L/s)流速(m/s)流量(L/s)0.0070.778.560.0080.839.150.0090.889.710.0100.826.290.9210.230.0150.711.970.864.251.007.711.1312.530.0200.822.281.004.911.168.901.3114.470.0250.700.860.922.551.125.491.299.951.4616.180.0300.770.951.012.791.226.011.4210.901.6017.720.0350.831.021.093.011.326.491.5311.771.7319.140.0400.891.091.163.221.416.941.6412.581.8520.460.0450.941.161.243.421.507.361.7413.351.9621.700.0500.991.22l.303.601.587.761.8314.072.0722.880.0551.041.281.373.781.658.141.9214.762.1724.000.0601.091.341.433.951.738.502.0015.412.2625.060.0651.131.391.484.111.808.852.0916.042.3626.090.0701.181.451.544.261.879.182.1716.652.4527.070.0751.221.501.594.411.939.502.2417.232.5328.020.0801.261.551.654.561.999.822.3117.802.6128.94建筑同層排水工程技術(shù)標(biāo)準(zhǔn)條文說明PAGEPAGE37PAGEPAGE38目 次1 總則 383 設(shè)計(jì) 39一般規(guī)定 39地面敷設(shè)方式 41沿墻敷設(shè)方式 42管道布置和敷設(shè) 43水力計(jì)算 44管材和接口 454 施工 474.1一般規(guī)定 47管道安裝 48隱蔽式支架安裝 495 驗(yàn)收 51驗(yàn)收要求 51工程竣工驗(yàn)收 511 總 則GB50015的要求,當(dāng)衛(wèi)生間的排水支管要求不穿越樓板進(jìn)入下層用戶時(shí)應(yīng)設(shè)置成同層排水;住宅衛(wèi)生間宜采用不降板同層排水?!蹲≌O(shè)計(jì)規(guī)范》GB50096,住宅污水排水橫管宜設(shè)于本層套內(nèi);《健康住宅建筑技術(shù)要點(diǎn)》,排水支管應(yīng)以本戶為界;住房和城鄉(xiāng)建設(shè)部和河北省住房和城鄉(xiāng)建設(shè)廳也分別和多次發(fā)布的推廣技術(shù),同層排水系統(tǒng)也做為住宅建筑的節(jié)水技術(shù)加以推廣采用。因?yàn)橥瑢优潘夹g(shù)是以排水管道暗敷的形式來實(shí)現(xiàn)污、廢水的排放,因此,同層排水技術(shù)必須堅(jiān)持以排水安全和提高居住建筑室內(nèi)環(huán)境為基礎(chǔ),并充分考慮到在技術(shù)應(yīng)用過程中所帶來的不利因素和影響。采用同層排水。同層排水工程的安全程度,主要由衛(wèi)生器具、管道、管材及配件和施工質(zhì)量決定,因此本條對所采用產(chǎn)品的標(biāo)準(zhǔn)做出明確規(guī)定。設(shè) 計(jì)一般規(guī)定對接、協(xié)商,同時(shí)也應(yīng)考慮建設(shè)單位的需求。目前我國建筑行業(yè)已經(jīng)應(yīng)用的同層排水方式,主要分為地面同一場所也可根據(jù)具體情況同時(shí)采用沿墻敷設(shè)和地面敷設(shè)。同層排水通常用于住宅和其他建筑類似套內(nèi)衛(wèi)生間,對于公共廁所中成組排列的多套大便器,排水橫管較長時(shí),不宜采用降板敷設(shè)方式。道安裝方式。時(shí)做為排水重要附件的存水彎也應(yīng)具備安裝和檢修方便的特點(diǎn)。3.1.7選用質(zhì)量可靠,安全節(jié)能的衛(wèi)生器具是滿足同層排水系統(tǒng)使用的最基本需要。設(shè)計(jì)及施工人員在衛(wèi)生器具選用時(shí),應(yīng)掌握和了解這些產(chǎn)品的性能特點(diǎn),以便于在工程中保證質(zhì)量。坐便器的選用應(yīng)按照《坐便器水效限定值及水效等級》GB25502選定。50mm。只有當(dāng)?shù)芈┑陌惭b40mm,才能保證管道系統(tǒng)出現(xiàn)正壓時(shí)不出現(xiàn)返水現(xiàn)象。水封的失去極易造成返臭、返溢等現(xiàn)象,應(yīng)引起重視。本條規(guī)定的原則沿用《建筑給水排水設(shè)計(jì)標(biāo)準(zhǔn)》GB50015中強(qiáng)制性條文的規(guī)定。存水彎,水封盒、水封井等能有效地隔斷排存水彎水封必須保證一定深度,考慮到水封蒸發(fā)損失、自虹吸損失以及管道內(nèi)氣壓變化等因素,國外規(guī)范均規(guī)定衛(wèi)生器具存水彎水封深度為50mm~100mm。此值也是重力流排水管道系統(tǒng)排水時(shí)內(nèi)壓波動(dòng),不至于把存水彎水封破壞的要求。個(gè)水封存在時(shí),可能會產(chǎn)生排水不暢(干擾),所以,設(shè)計(jì)中,當(dāng)衛(wèi)生器具自帶有水彎時(shí),不應(yīng)再設(shè)置存水彎。故對連接方式作出規(guī)定。地面敷設(shè)方式現(xiàn)同層排水。當(dāng)衛(wèi)生間面積較小,且室內(nèi)凈空高度足夠時(shí),由于地面敷設(shè)方式除排水立管外,基本不占用平面面積,并且排水支管較短,不必因?yàn)楣艿赖恼移露加锰蟮目臻g,因此宜采用地面敷設(shè)方式的同層排水。12個(gè)器具排水管的有水封地漏。由于多個(gè)排水器具共用水封,使得地漏的水封186的有關(guān)規(guī)定。會更大,因此應(yīng)避免滿管流的出現(xiàn)。防水要求。壓變形易產(chǎn)生滲漏,同時(shí)在填層中管道無需“可曲撓”,也應(yīng)酌情應(yīng)用。單位(開發(fā)商)為了避免衛(wèi)生間給水橫支管和熱水橫支管設(shè)在找平層及接口密閉性等指標(biāo)均應(yīng)嚴(yán)格控制,以免發(fā)生質(zhì)量事故。墊層內(nèi)管道的安裝和回填是降板式同層排水工程的重點(diǎn),應(yīng)采取的措施。沿墻敷設(shè)方式水方式。沿墻敷設(shè)方式通常把排水管道、大便器沖洗水箱都設(shè)置在隔墻內(nèi),現(xiàn)行行業(yè)標(biāo)準(zhǔn)《建筑同層排水部件》CJ/T363對衛(wèi)生器具也有相關(guān)規(guī)定。沿墻敷設(shè)的同層排水系統(tǒng)采用的大便器應(yīng)采用沖落式結(jié)構(gòu),排污方向?yàn)楹笈攀???蛇x用壁掛式坐便器和落地式后排水座(蹲)便器,沖洗水箱與大便器配套。沿墻敷設(shè)由于有了敷設(shè)排水管道的隔墻,會占用部分衛(wèi)生間面積,為了使衛(wèi)生間實(shí)際使用面積不減小,通常把沖洗水箱隱蔽在隔墻內(nèi)。浴盆和淋浴房排水口標(biāo)高較低,容易忽略存水彎的設(shè)置,導(dǎo)致有害氣體侵入室內(nèi)。因此,強(qiáng)調(diào)采用內(nèi)置存水彎的排水附件。地漏也應(yīng)保證水封?,F(xiàn)行行業(yè)標(biāo)準(zhǔn)《建筑同層排水附件》CJ/T363。原墻面的防水防潮,可采用無機(jī)防水涂料涂刷。規(guī)定。取的措施。管道布置和敷設(shè)3.4.2 衛(wèi)生器具排水性能與其排水口至排水橫支管之間的落差有3.4.5 排水橫管連接處要求上、下游橫管在水平方向傾斜角度在45°范圍內(nèi),目的在于改善上、下游排水管排水條件,不至于淹沒出流。3.4.7 3.4.11標(biāo)準(zhǔn)》GB50015中相關(guān)條款。水力計(jì)算充滿度是指重力排水系統(tǒng)的橫管水流在管渠中的充滿程度,hdh/dGB50015中規(guī)定室內(nèi)排水橫管的最大設(shè)計(jì)充滿度是十分必要的。同時(shí),充滿度過小,將影響排水橫管的水流工況,污物易于沉淀。歐洲標(biāo)準(zhǔn)中十分關(guān)注這個(gè)問題。3.5.6 排水管道坡度是影響坐便器污物輸送能力的重要因素。實(shí)驗(yàn)測試顯示,塑料排水管道在0.026標(biāo)準(zhǔn)坡度下,6L坐便器采用DN100和DN90管道的沖洗距離基本可以達(dá)到現(xiàn)行國家標(biāo)準(zhǔn)《衛(wèi)生陶瓷》GB6952對排水管道輸送距離的要求。隨著坡度的減小,沖洗離之小當(dāng)度最度0.046L坐器過DN10和DN90管道時(shí)均已小于自凈流速。因此,本標(biāo)準(zhǔn)要求建筑排水柔性接口鑄鐵管排水橫管采用通用坡度,建筑排水塑料管排水橫管宜采用標(biāo)準(zhǔn)坡度。生活污水橫支管不應(yīng)采用最小坡度。管材和接口3.6.2建筑同層排水系統(tǒng)經(jīng)過十多年的發(fā)展,從使用單位和設(shè)計(jì)單位的使用和調(diào)查反饋情況來看,早期采用大降板(結(jié)構(gòu)降板大于150mm)的同層排水,大部分采用了建筑排水硬聚氯乙

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

評論

0/150

提交評論