![《硅橡膠絕緣干式電力變壓器技術(shù)參數(shù)和要求》_第1頁(yè)](http://file4.renrendoc.com/view14/M02/16/2B/wKhkGWdvUy2AF1etAAD2yLicZdw723.jpg)
![《硅橡膠絕緣干式電力變壓器技術(shù)參數(shù)和要求》_第2頁(yè)](http://file4.renrendoc.com/view14/M02/16/2B/wKhkGWdvUy2AF1etAAD2yLicZdw7232.jpg)
![《硅橡膠絕緣干式電力變壓器技術(shù)參數(shù)和要求》_第3頁(yè)](http://file4.renrendoc.com/view14/M02/16/2B/wKhkGWdvUy2AF1etAAD2yLicZdw7233.jpg)
![《硅橡膠絕緣干式電力變壓器技術(shù)參數(shù)和要求》_第4頁(yè)](http://file4.renrendoc.com/view14/M02/16/2B/wKhkGWdvUy2AF1etAAD2yLicZdw7234.jpg)
![《硅橡膠絕緣干式電力變壓器技術(shù)參數(shù)和要求》_第5頁(yè)](http://file4.renrendoc.com/view14/M02/16/2B/wKhkGWdvUy2AF1etAAD2yLicZdw7235.jpg)
版權(quán)說(shuō)明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡(jiǎn)介
ICSFORMTEXT點(diǎn)擊此處添加ICS號(hào)FORMTEXT點(diǎn)擊此處添加中國(guó)標(biāo)準(zhǔn)文獻(xiàn)分類號(hào)T/CECT/CECFORMTEXTXXXXX—FORMTEXTXXXX硅橡膠干式變壓器技術(shù)參數(shù)和要求Technicalparametersandrequirementsofsiliconerubberdry-typetransformer(征求意見(jiàn)稿)FORMTEXTXXXX-FORMTEXTXX-FORMTEXTXX實(shí)施中國(guó)電力企業(yè)聯(lián)合會(huì)發(fā)布FORMTEXTXXXX-FORMTEXTXX-FORMTEXTXX發(fā)布T/CECXXXXX—202XPAGEPAGE1硅橡膠干式變壓器技術(shù)參數(shù)和要求1范圍本文件規(guī)定了硅橡膠干式變壓器的術(shù)語(yǔ)和定義、產(chǎn)品型號(hào)、使用條件、性能參數(shù)、技術(shù)要求、試驗(yàn)、標(biāo)志、包裝、運(yùn)輸和貯存、綠色低碳環(huán)保屬性等。本文件適用于設(shè)備最高電壓為35kV及以下,且至少有一個(gè)繞組的電壓高于1.1kV的硅橡膠干式變壓器。其它電壓等級(jí)和容量的硅橡膠干式變壓器可參照本標(biāo)準(zhǔn)執(zhí)行。2規(guī)范性引用文件下列文件中的內(nèi)容通過(guò)文中的規(guī)范性引用而構(gòu)成本文件必不可少的條款。其中,注日期的引用文件,僅該日期對(duì)應(yīng)的版本適用于本文件;不注日期的引用文件,其最新版本(包括所有的修改單)適用于本文件。GB/T1094.1《電力變壓器第1部分:總則》GB/T1094.3《電力變壓器第3部分:絕緣水平、絕緣試驗(yàn)和外絕緣空氣間隙》GB/T1094.10《電力變壓器第10部分:聲級(jí)測(cè)定》GB/T1094.11《電力變壓器第11部分:干式變壓器》GB/T1094.12《電力變壓器第12部分:干式電力變壓器負(fù)載導(dǎo)則》GB/T10228《干式電力變壓器技術(shù)參數(shù)和要求》GB20052《電力變壓器能效限定值及能效等級(jí)》GB/T2900.95《電工術(shù)語(yǔ)變壓器、互感器、調(diào)壓器和電抗器》GB/T191《包裝儲(chǔ)運(yùn)圖示標(biāo)志》JB/T3837《變壓器類產(chǎn)品型號(hào)編制方法》JB/T10088《6kV~1000kV級(jí)電力變壓器聲級(jí)》JB/T501《電力變壓器試驗(yàn)導(dǎo)則》HJ2543《環(huán)境標(biāo)志產(chǎn)品技術(shù)要求:干式電力變壓器》DL/T376《復(fù)合絕緣子用硅橡膠絕緣材料通用技術(shù)條件》GB/T1695《硫化橡膠工頻擊穿電壓強(qiáng)度和耐電壓的測(cè)定方法》GB/T1692《硫化橡膠絕緣電阻率的測(cè)定》GB/T528《硫化橡膠和熱塑性橡膠拉伸應(yīng)力應(yīng)變性能的測(cè)定》GB/T529《硫化橡膠和熱塑性橡膠撕裂強(qiáng)度的測(cè)定》GB/T1408.1《絕緣材料電氣強(qiáng)度試驗(yàn)方法第1部分工頻下試驗(yàn)》NB/T42093.1《干式變壓器絕緣系統(tǒng)熱評(píng)定試驗(yàn)規(guī)程》GB/T35553《城市軌道交通機(jī)電設(shè)備節(jié)能要求》GB/T10411《城市軌道交通直流牽引供電系統(tǒng)》JB/T10693《城市軌道交通用干式牽引整流變壓器》CJ/T370《城市軌道交通直流牽引供電整流機(jī)組技術(shù)條件》GB/T28001《職業(yè)健康安全管理體系》GB/T28180《變壓器環(huán)境意識(shí)設(shè)計(jì)導(dǎo)則》GB/T24001《環(huán)境管理體系》GB18599《一般工業(yè)固體廢物貯存和填埋污染控制標(biāo)準(zhǔn)》GB/T36132《綠色工廠評(píng)價(jià)通則》3術(shù)語(yǔ)和定義GB/T1094.1、GB/T1094.11和GB/T2900.95中界定的以及下列術(shù)語(yǔ)和定義適用于本文件。3.1 硅橡膠siliconerubber指干式變壓器繞組絕緣用可澆注硅橡膠,以下文中統(tǒng)一稱硅橡膠。3.2硅橡膠干式變壓器siliconerubberdry-typetransformer用硅橡膠澆注構(gòu)成變壓器高壓繞組縱絕緣和外包封絕緣,或者同時(shí)澆注構(gòu)成高壓和低壓繞組縱絕緣和外包封絕緣,磁路和繞組均不浸于絕緣液體中的變壓器。3.3過(guò)負(fù)載性能overloadperformance硅橡膠干式變壓器在過(guò)負(fù)載工況下運(yùn)行時(shí),在特定冷卻方式下變壓器不失去功能和安全性能的負(fù)載能力。3.4沖擊負(fù)載性能impactloadperformance硅橡膠干式變壓器的負(fù)荷從空載到額定負(fù)荷多次快速變化時(shí),變壓器不失去功能和安全性能的能力。3.5變壓器質(zhì)量massoftransformer硅橡膠干式變壓器本體不包含附件的總質(zhì)量。4產(chǎn)品型號(hào)硅橡膠干式變壓器型號(hào):SJC(B)□-□/□-□ 或:SCJ(B)□-□/□-□S——三相JC或CJ——硅橡膠澆注式B——低壓繞組箔式,如果低壓為線繞則空缺□——損耗性能水平代號(hào)□——額定容量□——額定電壓□——能效等級(jí)硅橡膠干式變壓器絕緣耐熱等級(jí)默認(rèn)為H級(jí)。 示例SJCB18-2000/10-NX1:表示為一臺(tái)三相、雙繞組、銅導(dǎo)線、高壓繞組線繞硅橡膠澆注,低壓繞組箔式線圈、無(wú)勵(lì)磁調(diào)壓、空氣自冷式、其損耗性能水平代號(hào)為18,額定容量為2000kVA,額定電壓為10kV,能效等級(jí)為1級(jí)、絕緣耐熱為H級(jí)的三相硅橡膠澆注干式變壓器。5使用條件5.1正常使用條件5.1.1海拔海拔不超過(guò)2000m。5.1.2冷卻介質(zhì)溫度冷卻介質(zhì)溫度按GB/T1094.11的4.2.2的規(guī)定。5.2特殊使用條件未列入5.1和GB/T1094.11中4.2正常使用條件中的任何使用條件。6性能參數(shù)電壓等級(jí)6kV、10kV、20kV、35kV的三相硅橡膠干式變壓器性能參數(shù)應(yīng)符合GB/T10228的要求。6kV、10kV系列三相硅橡膠干式配電變壓器更高性能參數(shù)應(yīng)符合GB20052的要求;20kV系列三相硅橡膠干式配電變壓器更高性能參數(shù)見(jiàn)表1;35kV系列三相硅橡膠干式配電和電力變壓器更高性能參數(shù)見(jiàn)表2、表3。表120kV級(jí)三相硅橡膠干式電工鋼帶鐵心無(wú)勵(lì)磁調(diào)壓配電變壓器性能參數(shù)損耗水平代號(hào)(18)(14)(13)(12)短路阻抗%額定容量kVA電壓組合及分接范圍聯(lián)結(jié)組標(biāo)號(hào)空載損耗kW負(fù)載損耗kW空載損耗kW負(fù)載損耗kW空載損耗kW負(fù)載損耗kW空載損耗kW負(fù)載損耗kW高壓kV高壓分接范圍%低壓kV180級(jí)(H)(145℃)180級(jí)(H)(145℃)180級(jí)(H)(145℃)180級(jí)(H)(145℃)50202224±2.5±50.4Dyn11Yyn00.2291.180.2591.180.2751.180.2751.316.01000.3641.9170.4121.9170.4371.9170.4372.131600.4502.380.5102.380.5402.380.5402.64200±2×2.5±50.4912.830.5572.830.5902.830.5903.142500.5663.290.6423.290.6803.290.6803.663150.6533.920.7403.920.7833.920.7834.364000.7734.660.8764.660.9274.660.9275.185000.9085.571.035.571.095.571.096.196301.036.591.166.591.236.591.237.328001.187.961.337.961.417.961.418.8410001.409.361.589.361.679.361.6710.412501.6111.071.8211.071.9311.071.9312.316001.8813.322.1313.322.2613.322.2614.820002.1815.752.4715.752.6215.752.6217.525002.6118.632.9618.633.1318.633.1320.720002.1817.192.4717.192.6217.192.6219.18.025002.6120.432.9620.433.1320.433.1322.7注:表中所列的負(fù)載損耗為H級(jí)絕緣系統(tǒng)(見(jiàn)GB/T1094.11的規(guī)定)下的值,表中未包括的其它絕緣系統(tǒng)溫度下的負(fù)載損耗需根據(jù)各自的參考溫度,以“180℃(H)”絕緣系統(tǒng)溫度的數(shù)據(jù)作參考進(jìn)行相應(yīng)的折算。表235kV級(jí)三相硅橡膠干式電工鋼帶鐵心無(wú)勵(lì)磁調(diào)壓配電變壓器性能參數(shù)損耗水平代號(hào)(18)(14)(13)(12)短路阻抗%額定容量kVA電壓組合及分接范圍聯(lián)結(jié)組標(biāo)號(hào)空載損耗kW負(fù)載損耗kW空載損耗kW負(fù)載損耗kW空載損耗kW負(fù)載損耗kW空載損耗kW負(fù)載損耗kW高壓kV高壓分接范圍%低壓kV180級(jí)(H)(145℃)180級(jí)(H)(145℃)180級(jí)(H)(145℃)180級(jí)(H)(145℃)503335363738.5±2.5±50.4Dyn11Yyn00.3041.370.3441.370.3651.370.3651.526.01000.4242.010.4802.010.5092.010.5092.231600.5332.700.6042.700.6392.700.6393.00200±2×2.5±50.5933.200.6723.200.7113.200.7113.552500.6683.650.7573.650.8013.650.8014.063150.7884.340.8934.340.9454.340.9454.824000.9235.211.055.211.115.211.115.795001.096.41.236.401.316.401.317.116301.257.411.427.411.507.411.508.238001.468.781.658.781.758.781.759.7610001.649.991.859.991.969.991.9611.112501.9112.242.1612.242.2912.242.2913.616002.1814.852.4714.852.6214.852.6216.520002.5717.552.9217.553.0917.553.0919.525003.0020.973.4020.973.6020.973.6023.3注:表中所列的負(fù)載損耗為H級(jí)絕緣系統(tǒng)(見(jiàn)GB/T1094.11的規(guī)定)下的值,表中未包括的其它絕緣系統(tǒng)溫度下的負(fù)載損耗需根據(jù)各自的參考溫度,以“180℃(H)”絕緣系統(tǒng)溫度的數(shù)據(jù)作參考進(jìn)行相應(yīng)的折算。表335kV級(jí)三相硅橡膠澆注干式電工鋼帶鐵心無(wú)勵(lì)磁調(diào)壓電力變壓器性能參數(shù)損耗水平代號(hào)(18)(14)(13)(12)短路阻抗%額定容量kVA電壓組合及分接范圍聯(lián)結(jié)組標(biāo)號(hào)空載損耗kW負(fù)載損耗kW空載損耗kW負(fù)載損耗kW空載損耗kW負(fù)載損耗kW空載損耗kW負(fù)載損耗kW高壓kV高低分接范圍%低壓kV180級(jí)(H)(145℃)180級(jí)(H)(145℃)180級(jí)(H)(145℃)180級(jí)(H)(145℃)8003335363738.5±2×2.5±53.1566.31010.511Dyn11Yd11Yyn01.529.001.729.001.829.001.8210.0610001.8010.42.0410.42.1610.42.1611.612502.1112.42.3912.42.5312.42.5313.816002.4914.92.8214.92.9914.92.9916.520002.8517.63.2317.63.4217.63.4219.5725003.2821.03.7221.03.9321.03.9323.331504.0723.64.6123.64.8823.64.8826.2840004.7328.45.3628.45.6828.45.6831.550005.6533.76.4033.76.7833.76.7837.463006.6839.37.5739.38.0239.38.0243.78000Dyn11Yd11YNd117.5844.48.5944.49.0944.49.0949.39100008.7053.59.8653.510.453.510.459.41250066.31010.51110.662.212.062.212.762.212.769.11600013.073.214.773.215.673.215.681.32000015.582.417.582.418.582.418.591.5102500018.297.220.797.221.997.221.9108注:表中所列的負(fù)載損耗為H級(jí)絕緣系統(tǒng)(見(jiàn)GB/T1094.11的規(guī)定)下的值,表中未包括的其它絕緣系統(tǒng)溫度下的負(fù)載損耗需根據(jù)各自的參考溫度,以“180℃(H)”絕緣系統(tǒng)溫度的數(shù)據(jù)作參考進(jìn)行相應(yīng)的折算。城市軌道交通35kV級(jí)三相硅橡膠干式配電變壓器、35kV級(jí)和10kV級(jí)硅橡膠干式牽引整流變壓器性能參數(shù)應(yīng)符合GB/T35553規(guī)定,或符合JB/T10693規(guī)定。7技術(shù)要求7.1總體要求按本標(biāo)準(zhǔn)制造的硅橡膠干式變壓器應(yīng)符合GB/T1094.11和GB/T10228和GB/T1094.12的規(guī)定;干式牽引整流變壓器應(yīng)符合JB/T10693規(guī)定。7.2硅橡膠的性能指標(biāo)要求表4硅橡膠性能指標(biāo)項(xiàng)目指標(biāo)固化后拉伸強(qiáng)度,MPa≥3.0扯斷伸長(zhǎng)率,>150撕裂強(qiáng)度kN/m≥10導(dǎo)熱系數(shù)W/m·k≥0.6體積電阻率,Ω?cm≥1.0×1012介電強(qiáng)度,kV/mm≥157.3硅橡膠干式變壓器繞組安全性能要求硅橡膠干式變壓器全壽命期內(nèi)局部放電應(yīng)不大于5pC。7.4硅橡膠干式變壓器主絕緣可靠性能要求硅橡膠干式變壓器主絕緣不能僅由空氣介質(zhì)構(gòu)成,應(yīng)加至少一層固體絕緣介質(zhì),構(gòu)成復(fù)合主絕緣。固體絕緣介質(zhì)應(yīng)滿足以下要求:a)應(yīng)能起到獨(dú)立的、不依賴于其它介質(zhì)的主絕緣作用,其設(shè)計(jì)介電強(qiáng)度應(yīng)不低于外施耐壓試驗(yàn)電壓的1.3倍;b)固體介質(zhì)的耐受溫度、機(jī)械強(qiáng)度應(yīng)符合7.1的要求;c)固體絕緣介質(zhì)的介電強(qiáng)度應(yīng)不受大氣環(huán)境條件影響;d)固體介質(zhì)壽命應(yīng)不低于變壓器的使用壽命。7.5硅橡膠干式變壓器高壓繞組表面絕緣性能要求硅橡膠干式變壓器的高壓繞組出線應(yīng)具有與繞組一體成型的硅橡膠絕緣子(或套管),以增強(qiáng)變壓器的繞組表面絕緣能力,提高變壓器整體防潮、防污性能。硅橡膠絕緣子(或套管)應(yīng)滿足以下要求:a)絕緣子(或套管)與繞組的硅橡膠外絕緣無(wú)界面接縫;b)每個(gè)絕緣子(或套管)應(yīng)能獨(dú)立承擔(dān)表面絕緣功能,與繞組本體表面構(gòu)成絕緣容錯(cuò)方式;c)每個(gè)絕緣子(或套管)的設(shè)計(jì)絕緣強(qiáng)度可根據(jù)運(yùn)行所處的大氣環(huán)境條件和外施耐壓試驗(yàn)電壓按照GB/T1094.3進(jìn)行計(jì)算。7.6硅橡膠干式變壓器燃燒性能要求硅橡膠干式變壓器應(yīng)按GB/T1094.11規(guī)定的變壓器燃燒試驗(yàn)方法進(jìn)行燃燒試驗(yàn),主要燃燒性能指標(biāo)應(yīng)滿足以下要求:排氣口測(cè)量段最高溫升<250K;排氣口測(cè)量段45min后的溫升<80K;排氣口測(cè)量段60min后的溫升<50K;試驗(yàn)開(kāi)始后20~60min間的排煙道測(cè)量段平均透光率>70%。7.7硅橡膠干式變壓器噪音性能要求硅橡膠干式變壓器噪音應(yīng)符合JB/T10088的規(guī)定。有低噪音要求的硅橡膠變壓器應(yīng)滿足以下要求:1000kVA及以下容量硅橡膠變壓器噪音不大于50dB(聲壓級(jí));1250kVA及以上容量硅橡膠變壓器噪音不大于55dB(聲壓級(jí))。7.8硅橡膠干式變壓器過(guò)負(fù)載性能要求硅橡膠干式變壓器在自冷條件下,100%負(fù)荷時(shí)變壓器應(yīng)能連續(xù)運(yùn)行,并具有如下1-3級(jí)負(fù)載能力。在風(fēng)扇輔助冷卻條件下,變壓器應(yīng)具有如下4-6級(jí)負(fù)載能力:過(guò)負(fù)載等級(jí)過(guò)電流倍數(shù)(p.u.=I/In)11.0p.u.連續(xù)運(yùn)行21.0p.u.連續(xù)運(yùn)行1.5p.u.1分鐘31.0p.u.連續(xù)運(yùn)行1.5p.u.2分鐘2.0p.u.10秒41.0p.u.連續(xù)運(yùn)行1.25p.u.2小時(shí)2.0p.u.10秒51.0p.u.連續(xù)運(yùn)行1.5p.u.2小時(shí)2.0p.u.1分鐘61.0p.u.連續(xù)運(yùn)行1.5p.u.2小時(shí)3.0p.u.1分鐘硅橡膠干式變壓器超過(guò)額定負(fù)載運(yùn)行時(shí)效率會(huì)下降,繞組溫度超過(guò)額定耐熱等級(jí)時(shí)繞組絕緣會(huì)加速老化,但變壓器安全性能不應(yīng)下降。硅橡膠干式變壓器需要過(guò)負(fù)荷連續(xù)運(yùn)行時(shí),應(yīng)與用戶另行商定。7.9硅橡膠干式變壓器高海拔條件下使用性能要求7.9.1溫升修正 硅橡膠干式變壓器在海拔不超過(guò)2000m使用時(shí),可不需要進(jìn)行溫升的修正。超過(guò)2000m使用時(shí)可按GB/T1094.11的10.3進(jìn)行必要的溫升修正。7.9.2試驗(yàn)條件修正硅橡膠干式變壓器固體絕緣強(qiáng)度不受氣壓影響,因此設(shè)計(jì)時(shí)僅對(duì)空氣絕緣距離進(jìn)行修正。修正系數(shù)參考GB/T1094.11的11.2。對(duì)變壓器進(jìn)行出廠例行試驗(yàn)時(shí)不需要修正試驗(yàn)電壓值,在安裝地應(yīng)按GB/T1094.11的規(guī)定正常進(jìn)行試驗(yàn)。8試驗(yàn)8.1硅橡膠干式變壓器試驗(yàn)應(yīng)符合GB/T1094.11、GB/T10228和本標(biāo)準(zhǔn)5、6和7的規(guī)定。8.2特殊使用環(huán)境溫度下硅橡膠干式變壓器的試驗(yàn)方法和判定合格的標(biāo)準(zhǔn)在用戶協(xié)議中另行規(guī)定。8.3硅橡膠材料應(yīng)進(jìn)行以下規(guī)定的試驗(yàn),項(xiàng)目包括:項(xiàng)號(hào)試驗(yàn)名稱試驗(yàn)方法試驗(yàn)類型1擊穿強(qiáng)度試驗(yàn)GB/T1408.1型式試驗(yàn)2體積電阻率試驗(yàn)GB/T1692型式試驗(yàn)3抗撕裂強(qiáng)度試驗(yàn)GB/T529型式試驗(yàn)4扯斷強(qiáng)度試驗(yàn)GB/T528型式試驗(yàn)5拉斷伸長(zhǎng)率試驗(yàn)GB/T528型式試驗(yàn)6耐電痕化和蝕損試驗(yàn)GB/T6553特殊試驗(yàn)9標(biāo)志、包裝、運(yùn)輸和貯存9.1硅橡膠干式變壓器各繞組應(yīng)有相應(yīng)的接線端子標(biāo)志,所有標(biāo)志應(yīng)牢固且耐腐蝕。9.2硅橡膠干式變壓器包裝箱外壁的文字與標(biāo)志應(yīng)耐受風(fēng)吹日曬,不應(yīng)因雨水沖刷而模糊不清,其內(nèi)容應(yīng)包括:a)制造單位名稱;b)收貨單位名稱及地址;c)產(chǎn)品名稱及型號(hào);d)毛質(zhì)量和變壓器總質(zhì)量;e)包裝箱外型尺寸;f)包裝箱儲(chǔ)運(yùn)指示標(biāo)志(其中“向上”“防濕”“小心輕放”“由此吊起”等標(biāo)志應(yīng)符合GB/T191的規(guī)定)。9.3隨硅橡膠干式變壓器裝箱的文件應(yīng)包括:a)裝箱單;b)銘牌標(biāo)志圖;c)外型尺寸圖;d)產(chǎn)品合格證書(shū)(包括例型試驗(yàn)數(shù)據(jù));e)產(chǎn)品使用說(shuō)明書(shū)。9.4硅橡膠干式變壓器的運(yùn)輸和貯存應(yīng)符合GB/T1094.11中5.3的規(guī)定。10綠色低碳環(huán)保屬性10.1安全屬性a)電氣安全滿足正常運(yùn)行條件下無(wú)需維護(hù)的要求;b)消防安全滿足很難燃、極少煙、不爆炸的要求;c)生物安全滿足制造過(guò)程、運(yùn)行過(guò)程、回收過(guò)程不產(chǎn)生對(duì)生物有毒有害物質(zhì)的要求。10.2環(huán)境屬性
溫馨提示
- 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 木工支模內(nèi)排架工程勞務(wù)分包合同-4
- 二零二五年度辦事處影視作品推廣合同
- 二零二五年度辦事處設(shè)計(jì)、施工、品牌授權(quán)合同
- 裝修合同清單模板(茶樓)
- 二零二五年度寶寶日間托管與營(yíng)養(yǎng)膳食合同
- 建筑工程施工合同終止協(xié)議年
- 數(shù)據(jù)分析與決策實(shí)戰(zhàn)指南
- 信息科技安全保障體系構(gòu)建
- 企業(yè)融資流程詳解和步驟說(shuō)明
- 酒店行業(yè)智能化客房智能控制系統(tǒng)方案
- 高質(zhì)量社區(qū)建設(shè)的路徑與探索
- 數(shù)字化時(shí)代的酒店員工培訓(xùn):技能升級(jí)
- 足球守門員撲救技巧:撲救結(jié)合守護(hù)球門安全
- 《學(xué)術(shù)規(guī)范和論文寫作》課件全套 第1-10章 知:認(rèn)識(shí)研究與論文寫作 - 引文規(guī)范
- 帶式輸送機(jī)滾筒出廠檢驗(yàn)規(guī)范
- 起重機(jī)更換卷筒施工方案
- 《信息檢索基礎(chǔ)知識(shí)》課件
- 具有履行合同所必須的設(shè)備和專業(yè)技術(shù)能力的承諾函-設(shè)備和專業(yè)技術(shù)能力承諾
- 01智慧物流信息技術(shù)概述
- 茶多糖和茶多酚的降血糖作用研究
- 混床計(jì)算書(shū)(新)
評(píng)論
0/150
提交評(píng)論