![Analytical Operation Skills_第1頁](http://file2.renrendoc.com/fileroot_temp3/2021-11/1/699c9bd8-cf61-4986-afee-679f62ca1b3e/699c9bd8-cf61-4986-afee-679f62ca1b3e1.gif)
![Analytical Operation Skills_第2頁](http://file2.renrendoc.com/fileroot_temp3/2021-11/1/699c9bd8-cf61-4986-afee-679f62ca1b3e/699c9bd8-cf61-4986-afee-679f62ca1b3e2.gif)
![Analytical Operation Skills_第3頁](http://file2.renrendoc.com/fileroot_temp3/2021-11/1/699c9bd8-cf61-4986-afee-679f62ca1b3e/699c9bd8-cf61-4986-afee-679f62ca1b3e3.gif)
![Analytical Operation Skills_第4頁](http://file2.renrendoc.com/fileroot_temp3/2021-11/1/699c9bd8-cf61-4986-afee-679f62ca1b3e/699c9bd8-cf61-4986-afee-679f62ca1b3e4.gif)
![Analytical Operation Skills_第5頁](http://file2.renrendoc.com/fileroot_temp3/2021-11/1/699c9bd8-cf61-4986-afee-679f62ca1b3e/699c9bd8-cf61-4986-afee-679f62ca1b3e5.gif)
版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡介
1、Analytical Operation SkillsContentsWeighing Use Electronic balance to get the accurate weight of standard or sample. Pipetting (volumetric pipette) Use pipette to measure and transport an accurate volume of solution from one container to another.Why are the two skills important?ARs work to attain th
2、e degree of precision and accuracyEvery standard begins with an accurately weighing with balance, an accurate dilution with pipetteEven a quality, calibrated balance or pipette can be unreliable if used incorrectlyBad habits ruin many of your resultsElectronic BalanceWorking PrincipleElectromagnetic
3、 balancing type (電磁力平衡) Electromagnetic force generated from a magnet and coil Balances in AR LabAnalytical Balance calibration range: 20mg-200g Accurate weighing Range: 20mg-100g (d=0.01mg) 100mg-200g (d=0.1mg)Balances in AR LabTop Loading calibration range: 1g-600g Accurate weighing range: 8.2-600
4、gBalances in AR LabMicro-balanceCalibration range: 2mg-2gAccurate Weighing Range: 2mg-2gBalances in AR LabUltra micro-balanceCalibration range: 1mg-2gAccurate Weighing Range:1mg-2gWeighingBalance StatusProcedureWeighing MethodsConsiderationBalance StatusEnvironment dustproof, shockproof, damp-proof,
5、 no significant temperature fluctuation keep the balance away from direct sunlight Flat, stable surface tablePower on for equilibrating at least 1 hourBalance StatusAdjust anchor bolts to keep bubble in the centerWeighing ProcedureDaily Calibration According to target weight, choose Balance with sui
6、table weight span Top-Loading: 1g-600g Analytical Balance: 20mg-200g Micro-Balance: 2mg-2g Ultra Micro-Balance: 1mg-2gMake sure the surroundings are clean. Make sure the pan is clean.Wear mask and glovesWeighing ProcedureUse tweezers or gloves to place the empty container you will use for the substa
7、nce to be measured on the balance platform. Weighing ProcedurePress the Tare button to automatically deduct the weight of the container from future calculations. Weighing ProcedureCarefully add the substance to the container. Weighing ProcedureWait for a while when the digital display is stable and
8、print the mass.Weighing ProcedureClean the pan and surroundings after weighing and tare the balance. balance brush bulb suck roll paper + MeOH/ACN Weighing Methods Direct weighing method (no hygroscopicity) 1. a suitable clean dry container on the pan 2. add target amount of sample to the container
9、3. weigh sample Weight loss weighing method (hygroscopic, volatile) 1. weigh total weight of sample and container Wt 2. transport certain amount of sample to target container 3. weigh the residual sample and container Wr 4. the obtained sample weight W=Wt-WrSpecial WeighingViscous Standard (Vit E) w
10、eighing boatLiquid Impurity Standard capillary tubeWeighing ConsiderationTemperature (2 ppm/C )Humidity, Wind, Shaky surfaceWeighing rangeBoth the inside and the outside should be kept clean Fingerprints and other greases from your hands Avoid Corrosive Chemicalsdrifting phenomenon of balance value
11、in one directionStatic electricity (40%RH)Sample close to the panImproper Weighing PracticeKnock on the panWindow openOverloadingWeighing paper too largeSweep powder into pan gapPipetting Rubber bulb volumetric pipetteThe Calibration ToleranceStandard of Accuracy-The capacity of tolerances for volum
12、etric pipette is that accepted by the National Institute of Standards and Technology (Class A). Use Class A volumetric pipette unless otherwise specified in the individual monography.Designated volume, mL125102550Limit of error, mL0.0060.0060.010.020.030.05Limit of error, %0.600.300.200.200.120.10Vo
13、lumetric Pipette CalibrationThe volumetric pipette is calibrated at 20C. Most pipettes are calibrated “to deliver”.T.D.-to deliverPipette should be drained in a vertical position and then touched against the wall of the receiving vessel to drain the tips.T.C.-to containPipette is called for in speci
14、al cases, generally for measuring viscous fluids like syrups; however, a volumetric flask may be substituted for a “to contain” pipette. In such case, the pipette should be washed clean. After drain and the washings added to the measured portion.Source of Pipette ErrorVolatile liquid evaporatesHigh
15、density liquid sinksViscous liquid sticksImmersed tips carry over liquidsAngled pipette take more liquidLiquid drops hold on the inner wall of pipetteHot or cold liquidHuman factorHow to use a volumetric pipetteExamine tip for breakagePre-wet the pipette by drawing up and dispending the chosen solut
16、ion a minimum of 3 times.How to use a volumetric pipette If your suction device is a rubber bulb, it ought NOT to be placed so that it is attached to the mouth of the pipette. How to use a volumetric pipetteAspirating Solution Squeeze the bulb Press against the mouth of pipette How to use a volumetr
17、ic pipetteImmerse tip in the solution to be measured (90 degree) Dont press the tip against the bottom 1-2cm from bottom Release the bulb slowly How to use a volumetric pipetteDraw up the liquid past several centimeters above the inscribed markDo not allow the solution to reach the bulb.Tip remains
18、beneath the surface How to use a volumetric pipetteQuickly remove the bulb and put your index finger over the open hole of the pipette How to use a volumetric pipetteWipe the tip to remove excess liquid outside the tipGently release the seal made by your finger until the bottom of the meniscus coinc
19、ides with the calibration mark on the pipette.How to use a volumetric pipetteDispensing Solution Drain pipette in a vertical position and then touched against the wall of the receiving VF (held at 45 degree angle) to drain the tipHow to use a volumetric pipetteA volumetric pipet should not be blown out to eject all liquid at the
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 2025-2030全球多人賽車游戲行業(yè)調(diào)研及趨勢(shì)分析報(bào)告
- 2025文旅項(xiàng)目新年穿越之旅宋韻中國年主題活動(dòng)策劃方案
- 第10講 俄羅斯(解析版)
- 2025個(gè)人財(cái)產(chǎn)信托合同的范本
- 2025抵押借款的標(biāo)準(zhǔn)合同范本
- 2025水毀工程監(jiān)理合同
- 海洋工程裝備研發(fā)生產(chǎn)合同
- 2025企業(yè)承包經(jīng)營合同書模板
- 提高財(cái)務(wù)管理能力的技巧
- 提高回答問題的技巧主題班會(huì)
- 2023風(fēng)電機(jī)組預(yù)應(yīng)力混凝土塔筒與基礎(chǔ)結(jié)構(gòu)設(shè)計(jì)標(biāo)準(zhǔn)
- 游戲賬號(hào)買賣合同
- 小學(xué)語文閱讀教學(xué)落實(shí)學(xué)生核心素養(yǎng)方法的研究-結(jié)題報(bào)告
- 一年級(jí)的成長歷程
- 2024年南京鐵道職業(yè)技術(shù)學(xué)院高職單招(英語/數(shù)學(xué)/語文)筆試歷年參考題庫含答案解析
- 正月十五元宵節(jié)介紹課件
- 病毒性肺炎疾病演示課件
- 中考英語語法填空專項(xiàng)練習(xí)附答案(已排版-可直接打印)
- 口腔醫(yī)學(xué)中的人工智能應(yīng)用培訓(xùn)課件
- 自然辯證法概論(新)課件
- 基層醫(yī)療機(jī)構(gòu)基本情況調(diào)查報(bào)告
評(píng)論
0/150
提交評(píng)論