1、變壓器摘要:變壓器是變電所的主要設(shè)備,功能是實(shí)現(xiàn)電網(wǎng)電壓的等級(jí)變換,基本工作原理是電磁感應(yīng)。變配電所是實(shí)現(xiàn)電壓等級(jí)變換和電能分配的場所。對供電電源進(jìn)行電壓等級(jí)變換,應(yīng)對電能進(jìn)行重新分配的場所稱為變電所。建筑變電所是供配電系統(tǒng)的樞紐,供電電源由電網(wǎng)引到變電所,在變電所完成降壓,電能分配等功能。關(guān)鍵詞: 變電所;變壓器;繼電保護(hù);1. 介紹要從遠(yuǎn)端發(fā)電廠送出電能,必須應(yīng)用高壓輸電。因?yàn)樽罱K的負(fù)荷,在一些點(diǎn)高電壓必須降低。變壓器能使電力系統(tǒng)各個(gè)部分運(yùn)行在電壓不同的等級(jí)。本文我們討論的原則和電力變壓器的應(yīng)用。2. 雙繞組變壓器變壓器的最簡單形式包括兩個(gè)磁通相互耦合的固定線圈。兩個(gè)線圈之所以相互耦合,是
2、因?yàn)樗鼈冞B接著共同的磁通。在電力應(yīng)用中,使用層式鐵芯變壓器(本文中提到的)。變壓器是高效率的,因?yàn)樗鼪]有旋轉(zhuǎn)損失,因此在電壓等級(jí)轉(zhuǎn)換的過程中,能量損失比較少。典型的效率范圍在92到99%,上限值適用于大功率變壓器。從交流電源流入電流的一側(cè)被稱為變壓器的一次側(cè)繞組或者是原邊。它在鐵圈中建立了磁通,它的幅值和方向都會(huì)發(fā)生周期性的變化。磁通連接的第二個(gè)繞組被稱為變壓器的二次側(cè)繞組或者是副邊。磁通是變化的;因此依據(jù)楞次定律,電磁感應(yīng)在二次側(cè)產(chǎn)生了電壓。變壓器在原邊接收電能的同時(shí)也在向副邊所帶的負(fù)荷輸送電能。這就是變壓器的作用。3. 有載情況下的變壓器一次側(cè)電壓和二次側(cè)電壓有著相同的極性,一般習(xí)慣上用點(diǎn)
3、記號(hào)表示。如果點(diǎn)號(hào)同在線圈的上端,就意味著它們的極性相同。因此當(dāng)二次側(cè)連接著一個(gè)負(fù)載時(shí),在瞬間就有一個(gè)負(fù)荷電流沿著這個(gè)方向產(chǎn)生。換句話說,極性的標(biāo)注可以表明當(dāng)電流流過兩側(cè)的線圈時(shí),線圈中的磁動(dòng)勢會(huì)增加??偟膩碚f,變壓器為了保持磁通是常數(shù),對磁通變化的響應(yīng)是瞬時(shí)的。更重要的是,在空載和滿載時(shí),主磁通0的降落是很少的(一般在)1至3%。其需要的條件是e降落很多來使電流ip增加。在一次側(cè),電流ip在一次側(cè)流過以平衡is產(chǎn)生的影響。它的磁動(dòng)勢npip只停留在一次側(cè)。因?yàn)殍F芯的磁通0保持不變,變壓器空載時(shí)空載電流i0必定會(huì)為其提供能量。故一次側(cè)電流ip是電流ip與i0的和。因?yàn)榭蛰d電流相對較小,那么一次
4、側(cè)的安匝數(shù)與二次側(cè)的安匝數(shù)相等的假設(shè)是成立的。因?yàn)樵谶@種狀況下鐵芯的磁通是恒定的。因此我們?nèi)耘f可以認(rèn)定空載電流i0相對于滿載電流是極其小的。當(dāng)一個(gè)電流流過二次側(cè)繞組,它的磁動(dòng)勢(nsis)將產(chǎn)生一個(gè)磁通,于空載電流i0產(chǎn)生的磁通0不同,它只停留在二次側(cè)繞組中。因?yàn)檫@個(gè)磁通不流過一次側(cè)繞組,所以它不是一個(gè)公共磁通。另外,流過一次側(cè)繞組的負(fù)載電流只在一次側(cè)繞組中產(chǎn)生磁通,這個(gè)磁通被稱為一次側(cè)的漏磁。二次側(cè)漏磁將使電壓增大以保持兩側(cè)電壓的平衡。一次側(cè)漏磁也一樣。因此,這兩個(gè)增大的電壓具有電壓降的性質(zhì),總稱為漏電抗電壓降。另外,兩側(cè)繞組同樣具有阻抗,這也將產(chǎn)生一個(gè)電阻壓降。把這些附加的電壓降也考慮在內(nèi)
5、,這樣一個(gè)實(shí)際的變壓器的等值電路圖就完成了。由于分支勵(lì)磁體現(xiàn)在電流里,為了分析我們可以將它忽略。這就符我們前面計(jì)算中可以忽略空載電流的假設(shè)。這證明了它對我們分析變壓器時(shí)所產(chǎn)生的影響微乎其微。因?yàn)殡妷航蹬c負(fù)載電流成比例關(guān)系,這就意味著空載情況下一次側(cè)和二次側(cè)繞組的電壓降都為零。4.變壓器的工作原理當(dāng)二次側(cè)電路開路是,即使原邊被施以正弦電壓vp,也是沒有能量轉(zhuǎn)移的。外加電壓在一次側(cè)繞組中產(chǎn)生一個(gè)小電流i。這個(gè)空載電流有兩項(xiàng)功能:(1)在鐵芯中產(chǎn)生電磁通,該磁通在零和m之間做正弦變化,m是鐵芯磁通的最大值;(2)它的一個(gè)分量說明了鐵芯中的渦流和磁滯損耗。這兩種相關(guān)的損耗被稱為鐵芯損耗。變壓器空載電流
6、i一般大約只有滿載電流的2%5%。因?yàn)樵诳蛰d時(shí),原邊繞組中的鐵芯相當(dāng)于一個(gè)很大的電抗,空載電流的相位大約將滯后于原邊電壓相位90º。顯然可見電流分量im= i0sin0,被稱做勵(lì)磁電流,它在相位上滯后于原邊電壓vp 90º。就是這個(gè)分量在鐵芯中建立了磁通;因此磁通與im同相。第二個(gè)分量ie=i0sin0,與原邊電壓同相。這個(gè)電流分量向鐵芯提供用于損耗的電流。兩個(gè)相量的分量和代表空載電流,即i0 = im+ ie應(yīng)注意的是空載電流是畸變和非正弦形的。這種情況是非線性鐵芯材料造成的。如果假定變壓器中沒有其他的電能損耗一次側(cè)的感應(yīng)電動(dòng)勢ep和二次側(cè)的感應(yīng)電壓es可以表示出來。因?yàn)?/p>
7、一次側(cè)繞組中的磁通會(huì)通過二次繞組,依據(jù)法拉第電磁感應(yīng)定律,二次側(cè)繞組中將產(chǎn)生一個(gè)電動(dòng)勢e,即e=n/t。相同的磁通會(huì)通過原邊自身,產(chǎn)生一個(gè)電動(dòng)勢ep。正如前文中討論到的,所產(chǎn)生的電壓必定滯后于磁通90º,因此,它于施加的電壓有180º的相位差。因?yàn)闆]有電流流過二次側(cè)繞組,es=vs。一次側(cè)空載電流很小,僅為滿載電流的百分之幾。因此原邊電壓很小,并且vp的值近乎等于ep。原邊的電壓和它產(chǎn)生的磁通波形是正弦形的;因此產(chǎn)生電動(dòng)勢ep和es的值是做正弦變化的。產(chǎn)生電壓的平均值如下eavg = turns×即是法拉第定律在瞬時(shí)時(shí)間里的應(yīng)用。它遵循eavg = n = 4fn
8、m其中n是指線圈的匝數(shù)。從交流電原理可知,有效值是一個(gè)正弦波,其值為平均電壓的1.11倍;因此e = 4.44fnm因?yàn)橐淮蝹?cè)繞組和二次側(cè)繞組的磁通相等,所以繞組中每匝的電壓也相同。因此ep = 4.44fnpm并且es = 4.44fnsm其中np和es是一次側(cè)繞組和二次側(cè)繞組的匝數(shù)。一次側(cè)和二次側(cè)電壓增長的比率稱做變比。用字母a來表示這個(gè)比率,如下式a = = 假設(shè)變壓器輸出電能等于其輸入電能這個(gè)假設(shè)適用于高效率的變壓器。實(shí)際上我們是考慮一臺(tái)理想狀態(tài)下的變壓器;這意味著它沒有任何損耗。因此pm = pout或者vpip × primary pf = vsis × sec
9、ondary pf這里pf代表功率因素。在上面公式中一次側(cè)和二次側(cè)的功率因素是相等的;因此vpip = vsis從上式我們可以得知 = a它表明端電壓比等于匝數(shù)比,換句話說,一次側(cè)和二次側(cè)電流比與匝數(shù)比成反比。匝數(shù)比可以衡量二次側(cè)電壓相對于一次惻電壓是升高或者是降低。為了計(jì)算電壓,我們需要更多數(shù)據(jù)。 終端電壓的比率變化有些根據(jù)負(fù)載和它的功率因素。實(shí)際上, 變比從標(biāo)識(shí)牌數(shù)據(jù)獲得, 列出在滿載情況下原邊和副邊電壓。 當(dāng)副邊電壓vs相對于原邊電壓減小時(shí),這個(gè)變壓器就叫做降壓變壓器。如果這個(gè)電壓是升高的,它就是一個(gè)升壓變壓器。在一個(gè)降壓變壓器中傳輸變比a遠(yuǎn)大于1(a>1.0),同樣的,一個(gè)升壓變
10、壓器的變比小于1(a<1.0)。當(dāng)a=1時(shí),變壓器的二次側(cè)電壓就等于起一次側(cè)電壓。這是一種特殊類型的變壓器,可被應(yīng)用于當(dāng)一次側(cè)和二次側(cè)需要相互絕緣以維持相同的電壓等級(jí)的狀況下。因此,我們把這種類型的變壓器稱為絕緣型變壓器。顯然,鐵芯中的電磁通形成了連接原邊和副邊的回路。在第四部分我們會(huì)了解到當(dāng)變壓器帶負(fù)荷運(yùn)行時(shí)一次側(cè)繞組電流是如何隨著二次側(cè)負(fù)荷電流變化而變化的。從電源側(cè)來看變壓器,其阻抗可認(rèn)為等于vp / ip。從等式 = a中我們可知vp = avs并且ip = is/a。根據(jù)vs和is,可得vp和ip的比例是 = = 但是vs / is 負(fù)荷阻抗zl,因此我們可以這樣表示zm (pr
11、imary) = a2zl這個(gè)等式表明二次側(cè)連接的阻抗折算到電源側(cè),其值為原來的a2倍。我們把這種折算方式稱為負(fù)載阻抗向一次側(cè)的折算。這個(gè)公式應(yīng)用于變壓器的阻抗匹配。transformerabstract:the transformer is the transformer substation major installation, the function realizes the network voltage rank transformation, the key job principle is the electromagnetic induction.changes the s
12、ubstation is realizes the voltage class transformation and the electrical energy assignment place. carries on the voltage class transformation to the electric power supply, deals with the place which the electrical energy carries on redistributes to be called the transformer substation. constructs t
13、he transformer substation is for electrical power distribution system's key position, the electric power supply directs the transformer substation from the electrical network, completes the voltage dropping in the transformer substation, functions and so on electrical energy assignment.key-words
14、: substation;transformer;relay protection;1. introductionthe high-voltage transmission was need for the case electrical power is to be provided at considerable distance from a generating station. at some point this high voltage must be reduced, because ultimately is must supply a load. the transform
15、er makes it possible for various parts of a power system to operate at different voltage levels. in this paper we discuss power transformer principles and applications.2. tow-winding transformersa transformer in its simplest form consists of two stationary coils coupled by a mutual magnetic flux. th
16、e coils are said to be mutually coupled because they link a common flux.in power applications, laminated steel core transformers (to which this paper is restricted) are used. transformers are efficient because the rotational losses normally associated with rotating machine are absent, so relatively
17、little power is lost when transforming power from one voltage level to another. typical efficiencies are in the range 92 to 99%, the higher values applying to the larger power transformers.the current flowing in the coil connected to the ac source is called the primary winding or simply the primary.
18、 it sets up the flux in the core, which varies periodically both in magnitude and direction. the flux links the second coil, called the secondary winding or simply secondary. the flux is changing; therefore, it induces a voltage in the secondary by electromagnetic induction in accordance with lenzs
19、law. thus the primary receives its power from the source while the secondary supplies this power to the load. this action is known as transformer action.3. transformers under loadthe primary and secondary voltages shown have similar polarities, as indicated by the “dot-making” convention. the dots n
20、ear the upper ends of the windings have the same meaning as in circuit theory; the marked terminals have the same polarity. thus when a load is connected to the secondary, the instantaneous load current is in the direction shown. in other words, the polarity markings signify that when positive curre
21、nt enters both windings at the marked terminals, the mmfs of the two windings add.in general, it will be found that the transformer reacts almost instantaneously to keep the resultant core flux essentially constant. moreover, the core flux 0 drops very slightly between n o load and full load (about
22、1 to 3%), a necessary condition if ep is to fall sufficiently to allow an increase in ip.on the primary side, ip is the current that flows in the primary to balance the demagnetizing effect of is. its mmf npip sets up a flux linking the primary only. since the core flux 0 remains constant. i0 must b
23、e the same current that energizes the transformer at no load. the primary current ip is therefore the sum of the current ip and i0.because the no-load current is relatively small, it is correct to assume that the primary ampere-turns equal the secondary ampere-turns, since it is under this condition
24、 that the core flux is essentially constant. thus we will assume that i0 is negligible, as it is only a small component of the full-load current.when a current flows in the secondary winding, the resulting mmf (nsis) creates a separate flux, apart from the flux 0 produced by i0, which links the seco
25、ndary winding only. this flux does no link with the primary winding and is therefore not a mutual flux.in addition, the load current that flows through the primary winding creates a flux that links with the primary winding only; it is called the primary leakage flux. the secondary- leakage flux give
26、s rise to an induced voltage that is not counter balanced by an equivalent induced voltage in the primary. similarly, the voltage induced in the primary is not counterbalanced in the secondary winding. consequently, these two induced voltages behave like voltage drops, generally called leakage react
27、ance voltage drops. furthermore, each winding has some resistance, which produces a resistive voltage drop. when taken into account, these additional voltage drops would complete the equivalent circuit diagram of a practical transformer. note that the magnetizing branch is shown in this circuit, whi
28、ch for our purposes will be disregarded. this follows our earlier assumption that the no-load current is assumed negligible in our calculations. this is further justified in that it is rarely necessary to predict transformer performance to such accuracies. since the voltage drops are all directly pr
29、oportional to the load current, it means that at no-load conditions there will be no voltage drops in either winding.4.transformer principleswhen a sinusoidal voltage vp is applied to the primary with the secondary open-circuited, there will be no energy transfer. the impressed voltage causes a smal
30、l current i to flow in the primary winding. this no-load current has two functions: (1) it produces the magnetic flux in the core, which varies sinusoidally between zero and m, where m is the maximum value of the core flux; and (2) it provides a component to account for the hysteresis and eddy curre
31、nt losses in the core. there combined losses are normally referred to as the core losses.the no-load current i is usually few percent of the rated full-load current of the transformer (about 2 to 5%). since at no-load the primary winding acts as a large reactance due to the iron core, the no-load cu
32、rrent will lag the primary voltage by nearly 90º. it is readily seen that the current component im= i0sin0, called the magnetizing current, is 90º in phase behind the primary voltage vp. it is this component that sets up the flux in the core; is therefore in phase with im.the second compon
33、ent, ie=i0sin0, is in phase with the primary voltage. it is the current component that supplies the core losses. the phasor sum of these two components represents the no-load current, ori0 = im+ ieit should be noted that the no-load current is distortes and nonsinusoidal. this is the result of the n
34、onlinear behavior of the core material. if it is assumed that there are no other losses in the transformer, the induced voltage in the primary, ep and that in the secondary, es can be shown. since the magnetic flux set up by the primary winding,there will be an induced emf e in the secondary winding
35、 in accordance with faradays law, namely, e=n/t. this same flux also links the primary itself, inducing in it an emf, ep. as discussed earlier, the induced voltage must lag the flux by 90º, therefore, they are 180º out of phase with the applied voltage. since no current flows in the second
36、ary winding, es=vs. the no-load primary current i0 is small, a few percent of full-load current. thus the voltage in the primary is small and vp is nearly equal to ep. the primary voltage and the resulting flux are sinusoidal; thus the induced quantities ep and es vary as a sine function. the averag
37、e value of the induced voltage given byeavg = turns×which is faradays law applied to a finite time interval. it follows thateavg = n = 4fnmwhich n is the number of turns on the winding. form ac circuit theory, the effective or root-mean-square (rms) voltage for a sine wave is 1.11 times the ave
38、rage voltage; thuse = 4.44fnmsince the same flux links with the primary and secondary windings, the voltage per turn in each winding is the same. henceep = 4.44fnpmandes = 4.44fnsmwhere ep and es are the number of turn on the primary and secondary windings, respectively. the ratio of primary to seco
39、ndary induced voltage is called the transformation ratio. denoting this ratio by a, it is seen thata = = assume that the output power of a transformer equals its input power, not a bad sumption in practice considering the high efficiencies. what we really are saying is that we are dealing with an id
40、eal transformer; that is, it has no losses. thuspm = poutorvpip × primary pf = vsis × secondary pfwhere pf is the power factor. for the above-stated assumption it means that the power factor on primary and secondary sides are equal; thereforevpip = vsisfrom which is obtained = ait shows th
41、at as an approximation the terminal voltage ratio equals the turns ratio. the primary and secondary current, on the other hand, are inversely related to the turns ratio. the turns ratio gives a measure of how much the secondary voltage is raised or lowered in relation to the primary voltage. to calc
42、ulate the voltage regulation, we need more information.the ratio of the terminal voltage varies somewhat depending on the load and its power factor. in practice, the transformation ratio is obtained from the nameplate data, which list the primary and secondary voltage under full-load condition.when the secondary voltage vs is reduced compared to the primary voltage, the transformation is said to be a step-down transformer: conversely, if this voltage is r
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲(chǔ)空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 人保財(cái)險(xiǎn)車險(xiǎn)合同范本
- 保理人合同范本
- 勞務(wù)派遣合同范本 司機(jī)
- 包工頭與臨時(shí)工人合同范本
- 勞務(wù)合同單包工合同范本
- 企業(yè)合同范本封面
- 勞務(wù)用工結(jié)算合同范本
- 單位采購書合同范本
- 醫(yī)院影像科合同范本
- 與商城簽約合同范本
- 第九屆鵬程杯五年級(jí)數(shù)學(xué)競賽初試真題
- 實(shí)驗(yàn)一 外科常用手術(shù)器械課件
- 電梯結(jié)構(gòu)與原理-第2版-全套課件
- 《現(xiàn)代漢語》語音教學(xué)上課用課件
- 采購流程各部門關(guān)系圖
- 《遙感導(dǎo)論》全套課件
- 力士樂工程機(jī)械液壓培訓(xùn)資料(共7篇)課件
- 村光伏發(fā)電申請書
- 降低混凝土路面裂縫發(fā)生率QC小組資料
- 【教師必備】部編版四年級(jí)語文上冊第二單元【集體備課】
- 支氣管擴(kuò)張的護(hù)理PPT
評(píng)論
0/150
提交評(píng)論