1、Milli-Q 及 Milli-Q A10 中文操作維護(hù)手冊(適用於 Academic/Gradient/Biocel/Synthesis 等機(jī)型)告知告知(請注意:此頁故意保留原文敘述)The information in this document is subject to change without notice and should not be construed as a commitment by Millipore Corporation. Millipore Corporation assumes no responsibility for any errors that

2、 might appear in this document. This manual is believed to be complete and accurate at the time of publication. In no event shall Millipore Corporation be liable for incidental or consequential damages in connection with or arising from the use of this manual.CopyrightCopyright 版權(quán)所有版權(quán)所有 2001 MILLIPO

3、RE CORPORATION. PRINTED IN FRANCE. ALL RIGHTS RESERVED.在未取得修改本出版品之批準(zhǔn)前,請勿以任何形式重製本書或部分內(nèi)容及格式Rev. 1 - 08/01TrademarksTrademarksMillipore is a registered trademark of Millipore Corporation.Elix, Q-Gard, Millipak and Milli-Q are registered trademarks of Millipore Corporation.Quantum, RiOs and A10 are trad

4、emarks of Millipore Corporation.Pyrogard is a registered trademark of Millipore Corporation.Teflon is a registered trademark of E.I. du Pont de Nemours & Co.Tygon is a registered trademark of the Norton Company.ASTM is a registered trademark of the American Society for Testing and Materials.Alle

5、n is a registered trademark of the Holo-Krome Technology Corporation.Santoprene is a registered trademark of Advanced Elastomer Systems.SLO-BLO is a registered trademark of Littlefuse, Inc.Windows and EXCEL are registered trademarks of Microsoft Corporation.All other trademarks are trademarks of the

6、ir respective manufacturers. 各型 Milli-Q 及 Milli-Q A10 ( (此頁之延伸含意表示所有此頁之延伸含意表示所有 MilliporeMillipore 純水系統(tǒng)皆通過歐洲純水系統(tǒng)皆通過歐洲 CECE 規(guī)範(fàn)規(guī)範(fàn)) )(請注意:此頁故意保留原文敘述)DECLARATIONDECLARATION OFOF CONFORMITYCONFORMITYEUROPEANEUROPEAN UNIONUNION ECEC DIRECTIVESDIRECTIVESDirective 89/336/CEEDirective 73/23/CEE These Lab Wat

7、er Systems are designed and manufactured in application of the following European Council directives : - 89/336/CEE relating to Electromagnetic compatibility.- 73/23/CEE relating to electrical equipment designed for use within certain voltage limits. Standards to which conformity is declared as appl

8、icable are the following :- EN 55022 Classe B: 1994: Limits and method of radio-disturbance characteristics of information technology equipment.- EN 50082-1: 1992: Electromagnetic compatibility: generic immunity standard.- EN 61010-1: 1993 /A2: 1995: Safety requirements for electrical equipment for

9、measurement, control, and laboratory use.ITIT ISIS IMPORTANTIMPORTANT TOTO READREAD THESETHESE INSTRUCTIONSINSTRUCTIONS BEFOREBEFORE USINGUSING THISTHIS EQUIPMENT.EQUIPMENT.Protection insured by this device could be compromised in case of wrong use. Please follow the provided information. It is high

10、ly recommended not to perform any work or maintenance to the internal parts or equipment of the system. All internal maintenance or part replacements are to be solely performed by Millipore service technicians.HereHere is is somesome additionaladditional informationinformation forfor technicaltechni

11、cal reference.reference.ElectricalElectrical specifications:specifications: Milli-QMilli-Q Synthesis:Synthesis: 230V,230V, 5050 Hz,Hz, 0.260.26 AmpsAmpsMilli-QMilli-Q SynthesisSynthesis A10:A10: 230V,230V, 5050 Hz,Hz, 0.260.26 AmpsAmpsThe rating and the specifications of all fuses used are listed in

12、 Chapter 9, Appendix 1 of this manual.The system must be electrically connected to an earth grounded power supply.In the event of any problems with this equipment, please do not hesitate to contact your local Millipore Service Representative.CHAPTER 1介紹 .11-1使用本手冊.1確認(rèn)本手冊與您的系統(tǒng)MILLI-Q相符.1如何使用按鍵及液晶螢?zāi)籐C

13、D.1本手冊常用之專業(yè)術(shù)語之縮寫.21-2安全性資訊.31-3MILLIPORE 全球分公司資料.4電話及傳真.4網(wǎng)際網(wǎng)路或電子郵件.4CHAPTER 2產(chǎn)品資訊.52-1MILLI-Q 精製水之規(guī)格.5MILLI-Q SYNTHESIS OR SYNTHESIS A10精製水.5流速.5比阻抗值.5顆粒.5熱源.5總有機(jī)碳.5微生物.5MILLI-Q 精製水水質(zhì)與 ASTM 標(biāo)準(zhǔn)試劑水規(guī)格之比較.52-2系統(tǒng)主要組件之配置圖.62-3主要組件之說明.7進(jìn)水電磁閥.7洩壓閥.7泵.7Q-GARD純化管匣.7Q-GARD 有多少不同型式 ?.7更換 Q-GARD 純化管匣之時機(jī)?.8UV燈.8U

14、V 燈之更換時機(jī) ?.8QUANTUM 超純水精製管匣.8QUANTUM 超純水精製管匣有多少不同型式?.8QUANTUM 超純水精製管匣之更換時機(jī)?.8超濾管匣 PYROGARD 5000 UF CARTRIDGE .9比阻抗計(jì).9比阻抗值與溫度測量.9溫度補(bǔ)償/導(dǎo)電度之顯示.9 符合 USP 24 版需求之 阻抗及溫度檢測.9出水雙向電磁閥 POU.9終端無菌過濾器.10MILLIPAK 終端無菌過濾器有幾種型式?.10MILLIPAK 之更換時機(jī) ?.10A10 TOC MONITOR(總有機(jī)碳監(jiān)測儀) .11A10 之作用為何 ? .11A10 之維護(hù)保養(yǎng)事項(xiàng)為何? .11A10 須要

15、進(jìn)行校正嗎? .11TOC SUITABILITY TEST(適應(yīng)性測試).112-4技術(shù)性規(guī)格.12尺寸大小 (SYSTEM AND CLEARANCE).12重量.12電力需求.12水質(zhì)測量範(fàn)圍TOC, RESISTIVITY, CONDUCTIVITY AND TEMPERATURE.12組件材質(zhì).13噪音.13CHAPTER 3安裝前檢查.143-1安裝前檢查表.143-2安裝前檢查表無臂式安裝前檢查表無臂式 MILLI-QS.153-33-3選配設(shè)備選配設(shè)備.16壁式固定架.16壓力調(diào)節(jié)器.16進(jìn)水閥.16遠(yuǎn)距式取水槍.16遠(yuǎn)距式取水槍安裝於無臂式Milli-Q.17腳踏板開関.17

16、連接印表機(jī)或電腦纜線.17遠(yuǎn)距式控制面板.17系統(tǒng)資料擷取軟體.173-4安裝需求.18安裝所需之耗材.18空間及承載重量要求.18電力要求.18進(jìn)水要求.19環(huán)境要求.19其他要求.193-5拆箱檢查.20CHAPTER 4安裝 .214-1連接進(jìn)水水源管線.21由儲水桶供水.21由有壓力之管線供水.214-2管線連結(jié)與電源.22進(jìn)水管.22進(jìn)水洩壓閥管線安裝.22超過濾膜排水軟管之安裝.22連接電源線.234-3安裝純化管匣 Q-GARD.234-4開啟系統(tǒng)電源.244-5安裝 QUANTUM 超純水精製管柱.244-6安裝 TYGON 排水軟管.244-7排出系統(tǒng)內(nèi)之氣體.254-8使系

17、統(tǒng)耗材水合 HYDRATING THE SYSTEM.264-9安裝並且沖洗最終過濾器 MILLIPAK.274-10如何對 MILLI-Q 系統(tǒng)之初水流速進(jìn)行校正.284-11如何切換設(shè)定面板顯示之語言.304-12如何設(shè)定螢?zāi)伙@示 M.CM 或 S/CM (比阻抗值或電導(dǎo)度值).314-13如何正確完成非溫度補(bǔ)償之阻抗值或電導(dǎo)度值顯示設(shè)定.33什麼是溫度補(bǔ)償? .33為什麼使用非溫度補(bǔ)償之?dāng)?shù)值? .334-14如何設(shè)定正確的日期及時間.36CHAPTER 5如何使用 MILLI-Q 純水系統(tǒng).385-1如何自 MILLI-Q 純水系統(tǒng)中取水.385-2待機(jī), 預(yù)操作及操作模式之功能說明.3

18、9什麼是待機(jī)模式什麼是待機(jī)模式(STANDBY MODE)?.39什麼是預(yù)操作模式什麼是預(yù)操作模式(Pre operate MODE)?.39什麼是操作模式什麼是操作模式(PRODUCT MODE)?.395-3如何檢視超純水之阻抗值,水溫及有機(jī)碳值.40檢視產(chǎn)水之阻抗值( RESISTIVITY) .40檢視產(chǎn)水溫度值.405-4如何使用腳踏開關(guān)(選項(xiàng)配備) .405-4如何使用腳踏開關(guān)(選項(xiàng)配備) .415-5如何取得正確體積的超純水.41如何去查看耗材的已使用時間(日期) .435-6如何去了解 MILLI-Q 的訊息義意.45CHAPTER 6維護(hù)保養(yǎng).486-1維護(hù)保養(yǎng)週期.486-

19、2如何更換 Q-GARD.496-3如何更換 QUANTUM CARTRIDGE超純水精製管柱.506-4如何更換 MILLIPAK.536-5如何消毒清洗 UF 膜組.54UF Cartridge 的消毒清洗頻率?.54UF Cartridge消毒清洗前您必須準(zhǔn)備下列事項(xiàng).54消毒及清洗UF CARTRIDGE.546-6如何清潔篩網(wǎng)過濾器.576-7如何調(diào)整 POU 固定臂的鬆緊度.586-8如何更換 A10 UV 燈.586-9如何清洗 A10 TOC 線上監(jiān)測器 .58A10 CLEANING 需要花多久時間 ?.58為什麼需要執(zhí)行 A10 CLEANING ?.58A10 CLEAN

20、ING 會自動執(zhí)行嗎 ?.58如何執(zhí)行 A10 CLEANING ?.59當(dāng)系統(tǒng)開始進(jìn)行 A-10 CLEANING 時如何取消?.606-10如何對 A10 TOC 監(jiān)測器進(jìn)行校正.606-11如何執(zhí)行排氣程序 AIR PURGE .616-12如何更換 UV 燈.62CHAPTER 7故障排除.63當(dāng)POU出水流速過低或無水流出時可能的原因.63出水比阻抗值過低可能的原因.64MILLI-Q 無電源可能的原因.65出現(xiàn) “ERROR NUMBER” 系統(tǒng)錯誤訊息.65出現(xiàn) “ERROR NUMBER” 系統(tǒng)錯誤訊息(續(xù)).66出現(xiàn)系統(tǒng)狀況訊息黃色及紅色LED燈閃爍.67其他故障排除項(xiàng)目.6

21、8CHAPTER 8訂購資訊.698-1耗材產(chǎn)品編號.698-2附屬配件之產(chǎn)品編號.708-3 MILLI-Q 系統(tǒng)之訂購編號識別.70CHAPTER 9附錄 .71附錄 1如何更換保險(xiǎn)絲.71附錄 2如何傳輸資料至印表機(jī)上.72REQUIREMENTS NEEDED.72WHAT TO DO.72WHAT DOES THE PRINTOUT LOOK LIKE ?.72WHAT DOES THE PRINTOUT LOOK LIKE ?.73附錄 3如何將系統(tǒng)資料下載至電腦上.74設(shè)備及工具要求設(shè)備及工具要求.74如何操作如何操作.74附錄 4如何使用遠(yuǎn)距式控制面板.77附錄 5如何使用遠(yuǎn)距

22、式 POU.77附錄 6溫度補(bǔ)償模式 COMP MODE 1 及 COMP MODE 2.78Chapter 1介紹1-1使用本手冊確認(rèn)本手冊與您的系統(tǒng) MILLI-Q相符 本手冊乃專為 Millipore Milli-Q Synthesis or Milli-Q Synthesis A10 純化水系統(tǒng)所設(shè)計(jì)編寫的.本手冊主要目的為引導(dǎo)客戶安裝,操作及維護(hù) Milli-Q Synthesis 或 Milli-Q Synthesis A10 純化水系統(tǒng)。 因此本公司強(qiáng)烈建議使用者在進(jìn)行安裝,操作及維護(hù) Milli-Q 純化水系統(tǒng)之前必須詳讀並且充分瞭解其內(nèi)容。您可以非常容易確認(rèn)您的系統(tǒng)為何,即使

23、您不知道系統(tǒng)產(chǎn)品編號,因?yàn)槊恳粋€系統(tǒng)的名稱就在系統(tǒng)正前方的橘色門上(Milli-Q Synthesis or Milli-Q Synthesis A10)。如果本手冊上之?dāng)⑹鲇袑兓到y(tǒng)不正確的描述請聯(lián)絡(luò) Millipore 公司,以便改進(jìn)。如何使用按鍵及液晶螢?zāi)?LCD按鍵及 LCD 安裝於 Milli-Q 純化水系統(tǒng)之正面上方的位置。按鍵的反應(yīng)有時會有些延遲,例如您想將 Milli-Q 系統(tǒng)由 STANDBY 模式切換成 PRE OPERATE 模式時。 此時您必須按”O(jiān)PERATE/STANDBY”鍵約兩秒鐘方可進(jìn)行切換Milli-Q 系統(tǒng)上共有四個按鍵分別為: OPERATE/STA

24、NDBY, MEASURE, CLEANING 及 MENU。 液晶螢?zāi)粸楸彻馐诫p列 16 字元 LCD 顯示幕 LED 指示燈則位於 LCD 之右邊的位置。 POWER LED 電源指示燈為綠色。 當(dāng)系統(tǒng)開機(jī)之後此燈便會持續(xù)亮著表示微處理器有電源供應(yīng)。 SERVICE LED維護(hù)保養(yǎng)指示燈為黃色。 當(dāng)系統(tǒng)有需要進(jìn)行維護(hù)保養(yǎng)之事項(xiàng)時 LCD 會出現(xiàn)訊息要求使用者進(jìn)行處理同時 SERVICE LED 會配合閃爍,例如:當(dāng) LCD 出現(xiàn)”EXCH. CARTRIDGES”時表示純化管匣必須更換。 ALARM LED警報(bào)指示燈為紅色。 當(dāng)系統(tǒng)出現(xiàn)異常之警報(bào)事項(xiàng)時 LCD 會出現(xiàn)警報(bào)訊息,要求使用者進(jìn)

25、行處理同時 ALARM LED 會配合閃爍,例如:當(dāng) LCD 出現(xiàn)”PAK NOT IN PLACE”,表示純化管匣未安裝於正確位置,導(dǎo)致系統(tǒng)出現(xiàn)警報(bào)情況。OPERATE / STANDBYMEASURECLEANINGMENUPOWERSERVICEALARMP R EO P E R A T EOPERATE / STANDBYMEASURECLEANINGMENUPOWERSERVICEALARMS T A N D B Y本手冊常用之專業(yè)術(shù)語之縮寫本手冊常用專業(yè)術(shù)語之縮寫會重複出現(xiàn)於文章之中,例如:液晶螢?zāi)豢s寫為 LCD。下表為常用專業(yè)術(shù)語之縮寫及其意義:專業(yè)術(shù)語之縮寫全文字義m微米(長度

26、單位)S/cm導(dǎo)電度之單位A10Millipore 公司之產(chǎn)品名稱主要目的為偵測超純水中總有機(jī)碳之含量ASTM美國材料暨測試協(xié)會名稱CFU/ml每毫升中所含之菌落數(shù)EDI電子式連續(xù)再生去離子模組(參考 Elix 系統(tǒng))Eu/ml每毫升中所含之內(nèi)毒素單位(內(nèi)毒素濃度)LCD液晶螢?zāi)籐ED發(fā)光二極體LPM公升/分鐘(流速)M.cm百萬歐姆公分(比阻抗值之單位)M.cm 25 C補(bǔ)償至 25 C 的比阻抗值mm毫米NPT公制管牙(管接頭之牙口型式)NPTF公制內(nèi)管牙NPTM公制外管牙OD管外徑ppb十億分之一; 微克/公升 (g/L)RO逆滲透SANIT.消毒TOC總有機(jī)碳UF超過濾管匣UV紫外光1

27、-2安全性資訊在操作使用 Milli-Q 系統(tǒng)之前使用者必須參照本手冊之安全性規(guī)範(fàn),特別是進(jìn)水及電源要求必須符合安全規(guī)範(fàn) 當(dāng)您在安裝或操作 Milli-Q 系統(tǒng)時參考本手冊的規(guī)範(fàn)是非常重要。若您將系統(tǒng)運(yùn)轉(zhuǎn)於不合格的環(huán)境或條件時將會危及純化水系統(tǒng)的正常運(yùn)轉(zhuǎn)。!THIS HAZARD symbol is used to refer to instructions in this manual that need to be done safely and carefullyTHIS ATTENTION symbol is used to refer to instructions in this

28、manual that need to be done carefully1-3MILLIPORE 全球分公司資料電話及傳真AUSTRALIATel. 1 800 222 111 or (02) 9888 8999Fax (02) 9878 0788AUSTRIA Tel. (01) 877-8926Fax (01) 877-1654BALTIC COUNTRIES Tel. +358 9 804 5110Fax +358 9 256 5660BELGIUM AND LUXEMBOURG Tel. +32 2 726 88 40Fax +32 2 726 98 84BRAZIL Tel. (0

29、11) 5548-7011Fax (011) 5548-7923CANADA Tel. 1-800-645-5476Fax 1-800-645-5439CHINA, PEOPLES REPUBLIC OF Beijing:Tel. (8610) 8519 1250(8610) 6518 1058Fax (8610) 8519 1255Guangzhou:Tel. (8620) 8755 4049Fax (8620) 8752 0172Hong Kong:Tel. (852) 2803 9111Fax (852) 2513 0313Shanghai:Tel. (8621) 5306 9100Fa

30、x (8621) 5306 0838CZECH REPUBLIC Tel. 02-2051 3841Fax 02-2051 4298DENMARK Tel. 70 10 00 23Fax 70 10 13 14EASTERN EUROPE, C.I.S., AFRICA, MIDDLE EAST AND GULF Life Sciences Division:Tel. +33 3 88 38 9536Fax +33 3 88 38 9539BioPharmaceutical Division:Tel. +43 1 877-8926Fax +43 1 877-1654Laboratory Wat

31、er Division:Tel. +33 1 30 12 7000Fax +33 1 30 12 7180FINLAND Tel. (09) 804 5110Fax (09) 256 5660FRANCE Tel. 01 30 12 7000Fax 01 30 12 7180GERMANY Tel. (06196) 494-0Fax (06196) 43901HUNGARY Tel. 1-205 9784Fax 1-205 9792INDIA Tel. (91) 80-839 46 57Fax (91) 80-839 63 45IRELANDLife Sciences and Laborato

32、ry Water Divisions:Tel. +44 1923 816375Fax +44 1923 818297BioPharmaceutical Division:Tel. (021) 883 666Fax (021) 883 048ITALY Vimodrone (Milano):Tel. (02) 25.07.81Fax (02) 26.50.324Roma:Tel. (06) 52.03.600Fax (06) 52.95.735JAPAN Tel. (03) 5442-9711Fax (03) 5442-9736 Life Sciences9737 BioPharm.9734 L

33、ab WaterKOREA Tel. (822) 551-0990Fax (822) 551-0228 MALAYSIA Tel. 603-757 1322Fax 603-757 1711MEXICO Tel. (525) 576-9688Fax (525) 576-8706THE NETHERLANDS Tel.axORWAYTel. 22 67 82 53Fax 22 66 04 60POLAND Tel. 22-669 12 2522-663 70 31Fax 22-663 70 33PUERTO RICO Tel. (787) 273

34、-8495Fax (787) 747-6553SINGAPORE Tel. (65) 842 1822Fax (65) 842 4988SPAIN AND PORTUGAL Tel. +34 917 283 960Fax +34 917 292 909SWEDEN Tel. 08-628 6960Fax 08-628 6457SWITZERLAND Volketswil:Tel. (01) 908-30-60Fax (01) 908-30-80Lausanne:Tel. (021) 641 2550Fax (021) 641 2551TAIWAN Taipei:Tel. (886-2) 279

35、2-9333Fax (886-2) 2792-6555U.K. Tel. 01923 816375Fax 01923 818297U.S.A. Tel. (781) 533-6000Fax (781) 533-3110IN ALL OTHER COUNTRIESMillipore Intertech (U.S.A.)Tel. +1 (781) 533-8622Fax +1 (781) 533-8630Phone numbers may change. See Millipores Internet site at for updated information.網(wǎng)際網(wǎng)路或電子郵件網(wǎng)際網(wǎng)路:電子

36、郵件: H2O 2產(chǎn)品資訊2-1MILLI-Q 精製水之規(guī)格MILLI-Q SYNTHESIS OR SYNTHESIS A10 精製水流速0.8 - 1.2 LPM with MilliPak Express 20比阻抗值大於 18.0 M.cm 25 CTypically 18.2 M.cm 25 C顆粒 1/ml (顆粒大小 0.22 m)熱源 0.001 Eu/ml總有機(jī)碳小於 5 ppb (此規(guī)格由下列條件進(jìn)行測試所得之結(jié)果: Milli-Q Synthesis 安裝 Q-Gard 1 純化管匣及Quantum EX 精製管匣,進(jìn)水則由 Millipore RiOs 逆滲透純水系統(tǒng)所

37、供應(yīng)。 其 TOC 值 50 ppb)。 當(dāng)進(jìn)水之 TOC 值若小於 50 ppb 時 Milli-Q 的產(chǎn)水TOC 值便可達(dá)到此規(guī)格微生物 1 CFU/mlMILLI-Q 精製水水質(zhì)與 ASTM 標(biāo)準(zhǔn)試劑水規(guī)格之比較Milli-Q 精製水水質(zhì)可符合或超越 ASTM 試劑水規(guī)格之標(biāo)準(zhǔn)。ASTM 試劑水規(guī)格之標(biāo)準(zhǔn)如下表所列。 Milli-Q Synthesis (或 Milli-Q Synthesis A10)之水質(zhì)規(guī)格如上所示。 (資料來源 “Standard Specification for Reagent Water”(試劑水規(guī)格之標(biāo)準(zhǔn)) Designation: D 1193 99;

38、American Society For Testing And Materials ASTM)ASTM Type I Standard Specifications for Reagent Grade WaterASTM 試劑水規(guī)格之標(biāo)準(zhǔn)Parameter(檢測項(xiàng)目)Value(數(shù)值)Conductivity 25 C (S/cm)導(dǎo)電度值0.056Resistivity 25 C (M.cm)比阻抗值18Total Silica max. value (g/L)總矽值3Total Organic Carbon max. value (g/L)TOC100Chlorides max. val

39、ue (g/L)餘氯值1Sodium max. value (g/L)總鈉值1pH 酸鹼值無規(guī)範(fàn) (在檢測試劑水頊目中排除 pH 的檢測是因?yàn)榇艘坏燃壷兯?不會含有足夠能影響 pH的污染物)進(jìn)水ABCDEMILLI-Q 出水FGH循環(huán)迴路IUF 排水洩壓閥洩壓閥 A-10 REJECT WATER PATHA-10 TOC 監(jiān)測裝置進(jìn)水ABCDEMILLI-Q 出水FGH循環(huán)迴路IUF 排水2-2系統(tǒng)主要組件之配置圖 Milli-Q Synthesis 純化水系統(tǒng)之流程圖如下圖所示。各主要組件之說明如下表所示。Milli-Q Synthesis 純化水系統(tǒng)之流程圖如下圖所示。各主要組件之說

40、明如下表所示。流程圖中之主要組件代碼說明A進(jìn)水電磁閥DUV 燈及外殼G比阻抗計(jì)B泵EQuantum 精製管匣H出水雙向電磁閥CQ-Gard 純化管匣FPyrogard 5000 NMW 超濾管匣IMilliPak 0.22um 終端無菌過濾器2-3主要組件之說明進(jìn)水電磁閥進(jìn)水電磁閥乃用於控制進(jìn)水水源進(jìn)入 Milli-Q 系統(tǒng)內(nèi),當(dāng)系統(tǒng)進(jìn)行內(nèi)循環(huán)行程或經(jīng)由 POU 出水時,進(jìn)水電磁閥會打開以使初級純水進(jìn)入系統(tǒng)內(nèi)。洩壓閥Milli-Q 系統(tǒng)內(nèi)建進(jìn)水洩壓閥,其主要目地在將大於 11psi 之進(jìn)水壓力作適當(dāng)?shù)恼{(diào)節(jié)使進(jìn)水壓力低於 11psi。 如此可避免 Milli-Q 系統(tǒng)在循環(huán)狀態(tài)時壓力過高,影響系

41、統(tǒng)正常運(yùn)作。系統(tǒng)配件包中附有一條 6mm 之 PE 管。 將此 PE 管安裝於系統(tǒng)後方之排水接頭上,另一端則放置於排水水槽中。 當(dāng)進(jìn)水壓力大於 11psi 時, 洩壓閥會打開並經(jīng)由此 PE 管將水排出系統(tǒng), 當(dāng)進(jìn)水壓力小於 11psi 時, 洩壓閥則會關(guān)閉, 若安裝調(diào)壓閥於系統(tǒng)與管路迴路之間時,則進(jìn)水壓力不至於會產(chǎn)生上述情形。詳細(xì)的安裝方法於安裝章節(jié)中有進(jìn)一步說明 Chapter 4 (安裝)。當(dāng) Milli-Q 的進(jìn)水是由儲水筒供應(yīng)時則無須安裝此排水 PE 管。若 Milli-Q 進(jìn)水是由有壓力之管路迴路供應(yīng)時則必須安裝此排水 PE 管。注意此洩壓閥以已內(nèi)建安裝於所有 Milli-Q 系統(tǒng)中

42、只有 PE 管是必須於裝機(jī)時安裝。泵泵主要的目地是提供進(jìn)水動能,使其能夠流經(jīng)純化單元(如 Q-Gard, Quantum, UV lamp, UF 膜)。使水質(zhì)純化以達(dá)到規(guī)範(fàn)之要求。Q-GARD 純化管匣Q-Gard 純化管匣是用於吸附水中之無機(jī)離子及有機(jī)物。 Q-Gard 為一體成形之消耗性組件。 此設(shè)計(jì)乃便於維修時進(jìn)行更換以及減少系統(tǒng)內(nèi)之死角降低水質(zhì)惡化之機(jī)率。Q-GARD 有多少不同型式 ?Q-Gard 1 乃用於進(jìn)水為逆滲透水, 蒸餾水或 EDI 水之初級純水系統(tǒng)。 例如 Millipore 之 RiOs 或 Elix 純化水系統(tǒng),此類進(jìn)水水質(zhì)較為穩(wěn)定:雖有些許的離子,但有機(jī)物、顆粒及

43、膠體等污染物卻明顯較少。Q-Gard 1 的產(chǎn)品編號為 QGARD00R1。 參考 Section 8-1 以取得進(jìn)一步的資料。Q-Gard 2 則用於其它以非上述水源為進(jìn)水之系統(tǒng), 例如去離子水系統(tǒng)(Service Deionised Water ),此類水系統(tǒng)一般為工廠製程用水,其製造過程為直接使用自來水(Tap water) 經(jīng)過陰陽離子交換樹脂產(chǎn)生之純水。 去離子水系統(tǒng)使用再生式陰陽離子交換樹脂有較多的有機(jī)物,顆粒及膠體等污染物。Q-Gard 1 的產(chǎn)品編號為 QGARD00R2。 參考 Section 8-1 以取得進(jìn)一步的資料。更換 Q-GARD 純化管匣之時機(jī)?Milli-Q S

44、ynthesis 系統(tǒng)更換 Q-Gard Pack 以時間為主要因素 (calendar days)。Milli-Q Synthesis 在純化管匣安裝 180 天後, LCD 會出現(xiàn) “EXCH. CARTRIDGES” 訊息。Milli-Q Synthesis A10 將不以時間做為更換管匣的依據(jù)。而是以比阻抗值及 TOC 值做為更換 Q-Gard, Quantum 及 Millipak 的依據(jù)。UV 燈雙波長 UV 燈發(fā)射 185 nm (降低 TOC ) 及 254 nm (殺菌效用)。 UV 燈安裝於 Q-Gard Pack 及 Quantum Cartridge之間,主要使用於殺菌

45、及降低有機(jī)物之含量。 UV 燈之產(chǎn)品編號為: ZMQUVLP01。UV 燈之更換時機(jī) ?Millipore 建議每一年更換一次 UV 燈。 Milli-Q 系統(tǒng)在開機(jī)後 365 天 LCD 會出現(xiàn)“EXCHANGE UV”訊息,提醒使用者更換 UV 燈。QUANTUM 超純水精製管匣Quantum 超純水精製管匣是用於吸附水中之微量無機(jī)離子及有機(jī)物。QUANTUM 超純水精製管匣有多少不同型式?Quantum IX 內(nèi)僅含核子級混床式離子交換樹脂。 此型式 Quantum 使用於需要離子濃度極低的應(yīng)用場合。Quantum IX 的產(chǎn)品編號為 QTUM000IX。 參考 Section 8-1

46、以取得進(jìn)一步的資料。Quantum EX 內(nèi)含核子級混床式離子交換樹脂及核子級合成活性碳,此型式之 Quantum 可應(yīng)用於需要同時有效降低微量離子濃度與微量有機(jī)物含量的超純水之使用者。Quantum EX 的產(chǎn)品編號為 QTUM000EX。 參考 Section 8-1 以取得進(jìn)一步的資料。The Quantum VX 內(nèi)含特殊粒子可吸附揮發(fā)性有機(jī)物並維持相當(dāng)微量的離子濃度。Quantum VX 的產(chǎn)品編號為 QTUM000VX。 參考 Section 8-1 以取得進(jìn)一步的資料。QUANTUM 超純水精製管匣之更換時機(jī)?Quantum 超純水精製管匣之更換建議與 Q-Gard 純化管匣相同

47、,並須同時更換,參考 “更換 Q-Gard 純化管匣之時機(jī)?”超濾管匣 PYROGARD 5000 UF CARTRIDGEPyrogard 5000 UF Cartridge 超濾管匣(在手冊中將直接稱為超濾管匣) 主要目的為去除 Milli-Q 超純水中之熱源或內(nèi)毒素。 超濾管匣亦可去除超純水中之細(xì)菌。超濾管匣必須進(jìn)行例行保養(yǎng),每四週使用氫氧化鈉執(zhí)行一次消毒程式。 超濾管匣之消毒程式詳述於本手冊之維護(hù)保養(yǎng)章節(jié)中。超濾管匣有一 8mm 排水管,必須安裝於 Milli-Q 後方之排水接頭(Drain 2) ,另一端則接至排水管線內(nèi)。 此排水管主要是將系統(tǒng)中被超濾管匣所攔截的細(xì)菌、熱源及顆粒排出

48、系統(tǒng),其排水與否則由一排水電磁閥控制。 此排水電磁閥於 PRE OPERATE 模式下每三個小時開 30 秒鐘或是系統(tǒng)執(zhí)行 AIR PURGE 時,會完全開啟以便快速排除雜質(zhì),當(dāng)系統(tǒng)執(zhí)行消毒程式時亦會完全開啟。比阻抗檢測器比阻抗值與溫度測量比阻抗計(jì)是用以測量 Milli-Q 水之電阻值。 在比阻抗計(jì)中內(nèi)建一溫度感測器(temperature sensor)。 溫度值會在Milli-Q 系統(tǒng) PRODUCT 模式時顯示於 LCD 上。溫度補(bǔ)償/導(dǎo)電度之顯示當(dāng)水流經(jīng)檢測器時,比阻抗值與溫度會被同時檢測。 Milli-Q 之微處理器會將電阻值補(bǔ)償成 25 C 之比阻抗值。 Milli-Q 可利用程式

49、軟體設(shè)定以顯示非溫度補(bǔ)償之比阻抗值。 利用按鍵更改程式軟體之功能,可將比阻抗值切換成導(dǎo)電度值顯示 (S/cm) ,同時可選擇有溫度補(bǔ)償或非溫度補(bǔ)償之顯示。比阻抗值/溫度檢測方法符合 USP24 版的相關(guān)規(guī)範(fàn)要求Millipore 之合格系統(tǒng)工程師可以展示 Milli-Q 比阻抗值與溫度之有效測量。比阻抗值/溫度之測量與 USP 24 版規(guī)範(fàn)之間有相關(guān)協(xié)定, 請與 Millipore 之系統(tǒng)工程師聯(lián)絡(luò)取得進(jìn)一步資訊。出水雙向電磁閥 POUPOU 取水槍內(nèi)有一電磁閥。當(dāng) POU 上的觸發(fā)器在最上方的位置時電磁閥關(guān)閉,即使系統(tǒng)在 PRE OPERATE Mode 時,電磁閥亦為關(guān)閉狀態(tài),當(dāng) POU

50、上的觸發(fā)器向下推時電磁閥便會開啟,此時超純水會由取水槍流出,而不會循環(huán)回 Pump(參考流程圖)。終端無菌過濾器終端無菌過濾器是一薄膜(Member)為基質(zhì)之過濾器,可攔截超純水中大於 0.22m 之顆粒及細(xì)菌。在 Milli-Q 水中所有比 0.22m 孔隙大的粒子會被截留於 Member 表面上,因此 Millipak 上的薄膜會因?yàn)?Milli-Q 水不斷地通過而使薄膜因細(xì)菌及顆粒的欄截導(dǎo)致阻塞。MILLIPAK 終端無菌過濾器有幾種型式?使用於 Milli-Q 系統(tǒng)上之 MilliPak Filters 共有兩種 (有時會稱之為終端過濾器終端過濾器)。無菌包裝之終端過濾器 Steril

51、e MilliPak 40 主要應(yīng)用為生命科學(xué)之實(shí)驗(yàn)運(yùn)用。Sterile MilliPak 40 的產(chǎn)品編號為 MPGL04SK2。 參考 Section 8-1 以取得有進(jìn)一步的資料。非無菌包裝之終端過濾器 Non Sterile MilliPak Express 20 主要用於分析科學(xué)之應(yīng)用其中包括微量揮發(fā)性有機(jī)物分析或 Life Science Applications where Endocrine Disrupter Analysis is being done。 Non Sterile MilliPak Express 20 的產(chǎn)品編號為 MPGP02001。 參考 Section

52、 8-1 以取得進(jìn)一步的資料。MILLIPAK 之更換時機(jī) ?MilliPak 之更換時機(jī),建議與 Q-Gard 純化管匣及 Quantum 超純水精製管匣同時更換,但是當(dāng) MilliPak 因顆?;蚣?xì)菌阻塞薄膜而導(dǎo)致 Milli-Q 出水流速降低時亦應(yīng)更換之A10 TOC MONITOR(總有機(jī)碳監(jiān)測儀)A10 之作用為何 ?A10 TOC Monitor 總有機(jī)碳監(jiān)測儀(以下稱以下稱 A10) 主要目的為測量 Milli-Q 水中之總有機(jī)碳(TOC)。 A10 模組安裝於 Milli-Q System 內(nèi)部。 在任何一部 Milli-Q 系統(tǒng)名稱後有加 A10 字樣者表示系統(tǒng)內(nèi)建 A10

53、TOC Monitor (例例如如: : Milli-Q Synthesis A10 vs. Milli-Q Synthesis)。每當(dāng) Milli-Q 由 PRE OPERATE 模式切換至 PRODUCT 模式時(POU 上的觸發(fā)器上的觸發(fā)器由上往由上往下推下推)便會進(jìn)行測量,每一次的測量須要 5 分鐘。當(dāng) TOC 值較高時系統(tǒng)會延長測量間隔至 9 或 12 分鐘。 當(dāng) Milli-Q 系統(tǒng)於 PRODUCT 模式時 A10 會進(jìn)行連續(xù)偵測。 A10 會在 PRE OPERATE 模式下每一個小時偵測一次。 當(dāng) Milli-Q 系統(tǒng)於STANDBY 模式時 A10 則不會進(jìn)行偵測。A10

54、之維護(hù)保養(yǎng)事項(xiàng)為何?A10 在進(jìn)行 TOC 偵測時是使用模組化之 UV 燈。 A10 UV Lamp 必須定期更換以避免因 UV Lamp 長久使用 UV強(qiáng)度衰減導(dǎo)致 TOC 測量產(chǎn)生不必要的誤差。 一般而言在正常使用情況下 UV 燈之壽命為一年。 Milli-Q 系統(tǒng)會自動記錄 A10 UV Lamp 之使用壽命。 當(dāng)系統(tǒng)開機(jī)超過 365 天時顯示幕上會出現(xiàn)”EXCHANGE A10 UV”之訊息 SERVICE LED 同時會閃爍 以提醒使用者更換 UV 燈。 A10A10 UVUV LampLamp 的產(chǎn)品編號為的產(chǎn)品編號為 ZFA10UV01ZFA10UV01。在 Milli-Q 之軔

55、體(software)中有一 A10 清潔模式,此模式會在系統(tǒng)剛開機(jī)時自動啟動。 A10 清潔模式不須要使用任何化學(xué)藥劑,在本手冊之保養(yǎng)維護(hù)章節(jié)中有詳細(xì)解說。A10 須要進(jìn)行校正嗎?本公司建議 A10 每一年進(jìn)行一次校正。 A10 無法進(jìn)行現(xiàn)場校正“on-site” 必須送回 Millipore 原廠進(jìn)行校正。 A10 之有效期為校正後一年有效。 更換 A10 UV 燈則為校正程式中的一個步驟。年度確效或完整的校正與否取決於使用者之要求。請聯(lián)絡(luò) Millipore 公司取得進(jìn)一步相關(guān)資訊(calibration or verification of the A10 TOC Monitor De

56、vice)TOC SUITABILITY TEST(適應(yīng)性測試)A10 TOC Monitor 可進(jìn)行 TOC 適應(yīng)性測試。請聯(lián)絡(luò) Millipore 公司取得進(jìn)一步相關(guān)資訊(TOC Suitability Test with an A10 TOC Monitor)2-4技術(shù)性規(guī)格尺寸大小 (系統(tǒng)及操作空間)Milli-Q Synthesis /Synthesis A10 之長寬高尺寸如下圖所列:重量Milli-Q Synthesis:操作重量 (wetted Q-Gard, Quantum and Millipak): 16 kg。Milli-Q Synthesis A10:操作重量:16.

57、8 kg.電力需求Milli-Q Synthesis/Milli-Q Synthesis A10 之供電需求如下:120 VAC 10%, 50/60 Hz. 0.5 安培,使用 2 安培延遲保險(xiǎn)絲。230 VAC 10%, 50/60 Hz. 0.26 安培,使用 1 安培延遲保險(xiǎn)絲。電源供應(yīng)與 Milli-Q 之間距離應(yīng)小於一公尺。 而電源則應(yīng)有接地線裝置。水質(zhì)測量範(fàn)圍 TOC, RESISTIVITY, CONDUCTIVITY AND TEMPERATUREMilli-Q 水質(zhì)測量範(fàn)圍如下:Resistivity 比阻抗值測量範(fàn)圍:2.4 18.2 M.cm (溫度補(bǔ)償至 25)Con

58、ductivity 導(dǎo)電度值測量範(fàn)圍:0.055 0.294 S/cmTemperature 溫度測量範(fàn)圍: 0 45 C (純指溫度計(jì)感測範(fàn)圍,而非指純水系統(tǒng)的可工作的溫度範(fàn)圍)TOC 測量範(fàn)圍:1 999 ppb256 mm296 mm445 mm74 mm778 mm336 mm20 mm190 mm組件材質(zhì)零組件與水直接接觸之材質(zhì)說明如下:ComponentMaterial of ConstructionCheck Valve 止逆閥PE, EPDM, Stainless SteelFittings 接頭PE, PA, PVDFInlet Solenoid Valve 進(jìn)水電磁閥Sta

59、inless Steel, POM, NBRManifold 歧管板PPOMilliPak 40最終過濾器(無菌包裝)PC Housing, PVDF MembraneMilliPak Express 20最終過濾器(非無菌包裝)SAN Housing, PES MembraneO-rings O 型環(huán)EPDMPack Adapter 純化管柱轉(zhuǎn)接器(where Q-Gard plugs in)ABSPOU Valve取水閥POM, NBR Seal, Stainless Steel, PTFEPump 泵Diaphragm = Santoprene/PTFE, Valves = EPDMQ-

60、Gard Pack純化管匣PP (tubes), PE (endcaps), EPDM O-ringsQuantum Cartridge超純水精製管柱Polypropylene (tube + endcaps), EPDM O-ringsResistivity Cell 比組抗計(jì)Stainless Steel 不銹鋼Screen Filter 篩網(wǎng)過濾器Stainless Steel 不銹鋼Tubing 純水用軟管PETubing Inserts軟管快速接頭組Rubber O-ring, stainless steel collar, PA insertUF Cartridge Membrane超過

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

評論

0/150

提交評論