1、目 錄第一章、 概述1.1前言···············································

2、83;················11.2檢查與安全注意事項(xiàng)·······························&#

3、183;··················11.3規(guī)格型號(hào)表······························

4、;····························41.4制動(dòng)單元與制動(dòng)電阻···················

5、3;······························5第二章、 安裝與接線2.1機(jī)箱結(jié)構(gòu)和尺寸················&

6、#183;·····································62.2安裝要求···········

7、;·················································82.3接

8、線要求·················································

9、83;··········82.4接線說(shuō)明······································&

10、#183;·····················9第三章、 運(yùn)行操作3.1操作面板·························&#

11、183;··································133.2操作鍵盤(pán)說(shuō)明·············

12、83;··········································133.3顯示內(nèi)容說(shuō)明·····

13、3;·················································

14、3;143.4參數(shù)修改方法················································

15、;········143.5試運(yùn)行········································

16、83;·····················15第四章、 功能參數(shù)一覽表··························&

17、#183;··················16附表1 多段速一、二、三通斷狀態(tài)與頻率的對(duì)應(yīng)關(guān)系表·······················36附表1 加減速時(shí)間選擇一、二通斷狀態(tài)與加

18、減速時(shí)間的對(duì)應(yīng)關(guān)系表············36第五章、故障處理方法5.1維護(hù)檢查注意事項(xiàng)································

19、83;···················375.2定期檢查專案····························

20、3;···························375.3故障信息及故障排除····················&#

21、183;·····························375.4故障及分析··················

22、3;·······································395.5常見(jiàn)異常現(xiàn)象及對(duì)策········&#

23、183;·········································41第六章、 品質(zhì)承諾······

24、83;············································43第一章 概 述1.1前言 FC300系列變頻器是針對(duì)各種專用場(chǎng)

25、合而精心設(shè)計(jì)的一款多功能高性能產(chǎn)品。調(diào)試參數(shù)簡(jiǎn)單實(shí)用,只須一鍵設(shè)置便可改為您需要的專用機(jī)型,再加上參數(shù)拷貝功能,使您在使用本變頻器時(shí)變得異常的簡(jiǎn)單。使用之前請(qǐng)務(wù)必熟讀此說(shuō)明書(shū),便于您更好的使用此變頻器,閱讀后請(qǐng)妥善保管,對(duì)以后的維護(hù),保護(hù)及其他使用場(chǎng)合有很好的幫助。 如在使用過(guò)程中存在著無(wú)法解決的問(wèn)題,請(qǐng)您隨時(shí)與本公司聯(lián)系。為了您的安全,請(qǐng)務(wù)必由合格的專業(yè)電機(jī)工程人員安裝調(diào)試及修改參數(shù)。本手冊(cè)中有 危險(xiǎn) 注意 等符號(hào)提醒您在搬運(yùn)、安裝、運(yùn)轉(zhuǎn)、檢查變頻器時(shí)的安全防范事項(xiàng),請(qǐng)您配合,使變頻器使用更加安全。1.2檢查與安全注意事項(xiàng) FC300系列變頻器在出廠之前已經(jīng)過(guò)測(cè)試和品質(zhì)檢驗(yàn),在購(gòu)買(mǎi)之后。拆箱

26、之前請(qǐng)檢查產(chǎn)品包裝是否因運(yùn)輸不慎而造成損失,產(chǎn)品的規(guī)格和型號(hào),是否與定購(gòu)機(jī)種相符,如有問(wèn)題請(qǐng)與本公司聯(lián)系。1.2.1 拆箱后檢查 1 內(nèi)含本機(jī)使用說(shuō)明書(shū)一本,保修卡及合格證一張。 2檢測(cè)變頻器側(cè)面的銘牌,以確定在您手上的產(chǎn)品是您說(shuō)定購(gòu)的產(chǎn)品。變頻器銘牌說(shuō)明變頻器型號(hào)說(shuō)明:1.2.2安全注意事項(xiàng) 危險(xiǎn) 錯(cuò)誤使用時(shí),可能造成人員傷亡。 注意 錯(cuò)誤使用時(shí),可能造成變頻器或機(jī)械系統(tǒng)損壞。 注意:根據(jù)情況的不同,“注意”等級(jí)事項(xiàng)也可能造成嚴(yán)重的后果,請(qǐng)遵循兩個(gè)等級(jí)的注意事項(xiàng),它們對(duì)我們的個(gè)人安全都很重要 危險(xiǎn)實(shí)施配線時(shí),請(qǐng)務(wù)必關(guān)閉電源。切斷交流電源十分鐘內(nèi),變頻器內(nèi)部仍有高壓,十分危險(xiǎn),請(qǐng)勿觸摸內(nèi)部電路

27、及零部件。運(yùn)轉(zhuǎn)時(shí),請(qǐng)勿檢查電路板上零部件及信號(hào)。請(qǐng)勿自行拆裝更改變頻器內(nèi)部連接線或線路,零部件。請(qǐng)勿用濕手操作開(kāi)關(guān)按鈕,防止觸電變頻器接地端請(qǐng)務(wù)必正確接地。嚴(yán)禁私自改裝、更換控制板及零部件,否則有觸電、發(fā)生爆炸等危險(xiǎn)。 注意在變頻器通電的情況下,千萬(wàn)不能打開(kāi)變頻器蓋,更不能觸摸線路板上的的元器件,這些元器件都帶有高壓,謹(jǐn)防觸電身亡!請(qǐng)勿對(duì)變頻器內(nèi)部的零部件進(jìn)行耐壓測(cè)試,這些半導(dǎo)體零件易受高壓損毀。絕不可將變頻器輸出端子U.V.W連接至交流電源。正在通電或斷開(kāi)電源不久,變頻器和制動(dòng)電阻處于高溫狀態(tài),請(qǐng)不要接觸它們,以免引起燙傷。各個(gè)端子上所加的電壓只能是使用手冊(cè)上所加的電壓,以防止爆裂,損壞等等

28、。變頻器主電路板CMOS、IC易受靜電影響及破壞,請(qǐng)勿觸摸主電路板。只有合格的專業(yè)人員才可以安裝、調(diào)試及保養(yǎng)變頻器。變頻器報(bào)廢請(qǐng)按工業(yè)廢物處理,嚴(yán)禁焚燒。變頻器長(zhǎng)時(shí)間保存后再使用,使用前必須進(jìn)行檢查和試運(yùn)行變頻器可以容易地進(jìn)行高速運(yùn)行的設(shè)定,更改設(shè)定之前,檢查電機(jī)和機(jī)械特性有充分的能力1.2.3搬運(yùn)和放置注意事項(xiàng)注意搬運(yùn)變頻器時(shí),請(qǐng)勿直接提取前蓋,應(yīng)由變頻器底座搬運(yùn),以防前蓋脫落,避免變頻器掉落,造成人員受傷或變頻器損壞。請(qǐng)將變頻器安裝于金屬類等不燃材料上,以防止發(fā)生火災(zāi)。請(qǐng)選擇安全的區(qū)域來(lái)安裝變頻調(diào)速器,防止高溫及日光直接照射,避免濕氣和水滴。請(qǐng)防止小孩或無(wú)關(guān)人員接近變頻調(diào)調(diào)速器。本變頻器只

29、能用在本公司所認(rèn)可的場(chǎng)所,未經(jīng)認(rèn)可的使用環(huán)境可能導(dǎo)致火災(zāi)、氣爆、感電等事故。若多臺(tái)變頻器安裝在同一控制柜內(nèi),請(qǐng)外加散熱風(fēng)扇,使箱內(nèi)溫度低于40,以防止過(guò)熱或火災(zāi)等發(fā)生。請(qǐng)確認(rèn)切斷電源后,再拆卸或裝入操作鍵盤(pán),并固定前蓋,以免接觸不良,造成操作器故障或不顯示請(qǐng)不要把變頻器安裝在含有爆炸性氣體的環(huán)境里,否則有引發(fā)爆炸的危險(xiǎn)在海拔超過(guò)1000米的地區(qū),變頻器散熱效果變差,請(qǐng)降檔使用。輸出側(cè)請(qǐng)不要安裝接觸器及有關(guān)電容或壓敏電阻等器件,否則會(huì)引起變頻器故障及器件損壞。輸出側(cè)請(qǐng)不要安裝空開(kāi)和接觸器等開(kāi)關(guān)器件,如果由于工藝及其他方面需要必須安裝,則必須保證開(kāi)關(guān)動(dòng)作時(shí)變頻器無(wú)輸出,另外,輸出側(cè)嚴(yán)禁安裝有改善功

30、率因的電容或防雷用壓敏電阻,否則,會(huì)造成變頻器故障,跳保護(hù)或元器件損壞。變頻器請(qǐng)使用獨(dú)立電源,絕對(duì)避免與電焊機(jī)等共同用一電源,否則會(huì)引起變頻器保護(hù)或損壞。 注意送電前 所選用電源電壓必須與變頻器輸入電壓規(guī)格相同。 PE 符號(hào)為接地端子,請(qǐng)確實(shí)將電機(jī)及變頻器正確接地,以確保安全。 當(dāng)電源與變頻器之間有安裝接觸器時(shí),請(qǐng)不要用接觸器來(lái)控制變頻器的起動(dòng)或停止,否則,會(huì)影響變頻器的使用壽命。 主回路端子配線必須正確,R.S.T(L.N)為電源輸入端子,絕對(duì)不可接在上,否則在送電時(shí),將造成變頻器的損壞。送電中 送電中絕不可插拔變頻器上的連接器以避免控制主板因插拔所產(chǎn)生突波進(jìn)入,造成變頻器損壞。送電前請(qǐng)蓋好

31、蓋板,以防觸電,造成人身傷害。運(yùn)轉(zhuǎn)中 變頻器運(yùn)轉(zhuǎn)中嚴(yán)禁將馬達(dá)機(jī)組投入或切離,否則會(huì)造成變頻器過(guò)電流跳脫,甚至將變頻器主回路燒毀 變頻器送電中請(qǐng)勿取下前蓋,以防觸電引起傷亡。 在開(kāi)啟故障再啟動(dòng)功能時(shí),馬達(dá)在運(yùn)轉(zhuǎn)停止后會(huì)自動(dòng)再啟動(dòng),請(qǐng)勿靠近機(jī)器,以免發(fā)生意外。 停止開(kāi)關(guān)的功能須設(shè)定才有效,與緊急停止開(kāi)關(guān)的用法不同,請(qǐng)注意使用。1.3規(guī)格型號(hào)表三相440V級(jí)功率KW0.751.52.23.03.75.57.5111518.5適配電機(jī)功率KW0.751.52.23.03.75.57.5111518.5輸入額定電流A4.06.38.21214.51925334652電壓V三相380V±15%頻

32、率HZ50/60Hz輸出額定電流A2.74.25.58.09.51318243238電壓V三相0-380V頻率HZ0-1000Hz過(guò)載保護(hù)200% 立即過(guò)流150%一分鐘.單相230V級(jí)功率KW0.751.52.23.03.75.57.5111518.5適配電機(jī)功率KW0.751.52.23.03.75.57.5111518.5輸入額定電流A7.51116222736497396111電壓V單相220V±15%頻率HZ50/60Hz輸出額定電流A5.07.01115182533496575電壓V三相0-220V頻率HZ0-1000Hz過(guò)載保護(hù)200% 立即過(guò)流150%一分鐘.(注)1

33、)最大適配電機(jī)是指該型號(hào)變頻器驅(qū)動(dòng)的最大功率輕負(fù)載電機(jī),并以4極電機(jī)為標(biāo)準(zhǔn)。2)額定輸出電流是指輸出電壓為380V(或220V)時(shí)的輸出電流。3)超載能力是以過(guò)電流與變頻器的額定電流之比的百分?jǐn)?shù)(%)表示的反復(fù)使用時(shí)必須等待變頻器和電機(jī)降到100%負(fù)荷時(shí)的溫度以下。4)最大輸出電壓不能大于電源電壓,在電源電壓以下可以任意設(shè)定輸出電壓(變頻器輸出端電壓的峰值為直流電壓)。5)電源容量隨著電源側(cè)的阻抗(包括輸入電抗器和電線)的值而變化。1.4制動(dòng)單元與制動(dòng)電阻變頻器制動(dòng)單元制動(dòng)電阻電壓功率KW 配置方式規(guī)格用量配置方式規(guī)格用量單相220V0.75預(yù)置1外置100W /15011.5預(yù)置1外置400

34、W/10012.2預(yù)置1外置600W/10013.0預(yù)置1外置800W/10013.7預(yù)置1外置800W/1001三相380V0.55預(yù)置1外置100W /75010.75預(yù)置1外置100W /75011.5預(yù)置1外置260W/40012.2預(yù)置1外置260W/25013.0預(yù)置1外置260W/20013.7預(yù)置1外置390W/15015.5預(yù)置1外置520W/15017.5預(yù)置1外置780W/100111內(nèi)置1外置1040W/75115內(nèi)置1外置1560W/75118.5內(nèi)置1外置4800W/401第二章 安裝和接線本章為產(chǎn)品的基本“安裝和接線”,使用前請(qǐng)仔細(xì)閱讀本章的注意事項(xiàng)。2.1機(jī)箱結(jié)

35、構(gòu)和尺寸FC300機(jī)箱外形圖如下:FC300塑殼機(jī)箱外形圖如下:FC300列變頻器的外形尺寸如下表:變頻器型號(hào)安裝尺寸外形尺寸W(mm)H(mm)D(mm)W1(mm)H1(mm)d(mm)FC300-0.75T210018015787.51704.5FC300-1.5T2FC300-0.75T4FC300-1.5T4FC300-2.2T4FC300-2.2T21352401701252304.5FC300-3.0T2FC300-3.0T4FC30-3.7T4FC30-5.5T4FC300-7.5T42123401952023206.5FC300-11T4FC300-15T4267422225

36、2504056.5FC300-18.5T42.2安裝要求由于變頻器屬于精密的功率電力電子產(chǎn)品,其現(xiàn)場(chǎng)安裝的好壞,環(huán)境的優(yōu)劣直接影響變頻器的正常工作和使用壽命,故要求如下:檢查變頻器安裝地點(diǎn)環(huán)境跟本手冊(cè)第一章中”使用環(huán)境要求是否相符”不相符請(qǐng)不要安裝,否則會(huì)損壞變頻器。變頻器使用了塑料零件,請(qǐng)不要在蓋板上使用太大的力,小心安裝,以免造成破損。2.2.3條件允許請(qǐng)將變頻器背面或散熱片露裝于電控柜外,可以大幅度降低電控柜內(nèi)產(chǎn)生的溫度。將變頻器盡可能安裝在清潔的場(chǎng)所,或可阻擋任何懸浮物質(zhì)的封閉型屏板內(nèi)。變頻器要用螺絲垂直且牢固地安裝在安裝板上。注意變頻器安裝在電控柜內(nèi)的散熱方法:在兩臺(tái)或兩臺(tái)以上變頻器

37、以及通風(fēng)扇安裝在一個(gè)電控柜內(nèi)時(shí),應(yīng)注意正確的安裝位置,以確保變頻器周?chē)鷾囟仍谠试S值以內(nèi)。如安裝位置不正確,會(huì)使變頻器周?chē)鷾囟壬仙?,降低通風(fēng)效果。請(qǐng)安裝在不可燃的表面上。變頻器可能達(dá)到很高溫度(大約80)。 請(qǐng)安裝在不可燃表面上(例如:金屬),同時(shí),為了使熱量易于散發(fā),應(yīng)在其周?chē)粲凶銐虻目臻g。(見(jiàn)附圖)23接線要求 安裝布線時(shí)應(yīng)將電源線和控制電纜分開(kāi),例如使用獨(dú)立的線槽等。如果控制電路聯(lián)機(jī)必須和電源電纜交叉,應(yīng)成90交叉布線。使用屏蔽導(dǎo)線或雙絞線連接控制電路時(shí),確保未屏蔽之處盡可能短,條件允許時(shí)應(yīng)采用電纜套管。避免變頻器的重力線(輸出輸入線)與信號(hào)線平行布線和集束布線,應(yīng)分散布線。檢測(cè)器的連接

38、線,控制用信號(hào)線,使用雙絞屏蔽線,屏蔽線的外皮連接COM端。變頻器,電機(jī)等等的接地線接到同一點(diǎn)上。加數(shù)據(jù)線濾波器到信號(hào)線上。將檢測(cè)器的連接線,控制用信號(hào)線的屏蔽層用電纜金屬夾鉗接地。2.4接線說(shuō)明主回路端子說(shuō)明端子記號(hào)端子名稱說(shuō)明L、N交流電源輸入連接工頻電源單相AC220V 50-60Hz三相AC230V或380V50-60 HzR、S、TU、V、W變頻器輸出接三相異步電機(jī)P+、PB連接制動(dòng)電阻在P+、PB之間連接制動(dòng)電阻(15KW 以下)PE接地變頻器接地用,必須正確接地控制回路端子說(shuō)明端子記號(hào)端子名稱說(shuō)明AVI頻率設(shè)定電壓輸入輸入0-10V,PID給定或回饋ACI頻率設(shè)定電流輸入輸入4-

39、20mA,PID給定或回饋AFM0V-10V輸出可用來(lái)指示頻率、電流、轉(zhuǎn)速等10V頻率設(shè)定輔助電源與AVI,GND連接電位器(4.7K-10K)X1多功能輸入端子1功能由參數(shù)P091設(shè)定,出廠值為“正轉(zhuǎn)啟動(dòng)”X2多功能輸入端子2功能由參數(shù)P092設(shè)定,出廠值為“反轉(zhuǎn)啟動(dòng)”X3多功能輸入端子3功能由參數(shù)P093設(shè)定,出廠值為“停止”X4多功能輸入端子4功能由參數(shù)P094設(shè)定,出廠值為“正轉(zhuǎn)點(diǎn)動(dòng)”X5多功能輸入端子5功能由參數(shù)P095設(shè)定,出廠值為“多段速一”X6多功能輸入端子6功能由參數(shù)P096設(shè)定,出廠值為“多段速二”X7多功能輸入端子7功能由參數(shù)P097設(shè)定,出廠值為“多段速三”X8多功能輸

40、入端子8功能由參數(shù)P098設(shè)定,出廠值為“外部故障”Y2A、Y2B繼電器觸點(diǎn)輸出Y2A、Y2B為常開(kāi)觸點(diǎn)Y1A、Y1B、Y1C繼電器觸點(diǎn)輸出Y1A、Y1B為常開(kāi)觸點(diǎn)、Y1B、Y1C為常閉觸點(diǎn)COM、12V輔助電源COM、+12V50mA,COM為模擬輸入輸出和多功能端子公共地主回路接線說(shuō)明1)電源及電機(jī)接線的壓線端子。請(qǐng)使用帶絕緣管的端子。2)切記電源一定不能接到變頻器輸出端子上(U,V,W),否則將損壞變頻器。3)接線后,零碎線頭必須清除干凈,零碎線頭可能造成異常,失靈和故障,必須始終保持清潔。在控制臺(tái)上打孔時(shí),請(qǐng)注意不要使碎片粉未等進(jìn)入變頻器中。4)為使電壓壓降在2%以內(nèi),請(qǐng)用適當(dāng)型號(hào)的電

41、線接線。變頻器和電機(jī)間的接線距離較長(zhǎng)時(shí),特別是低頻率輸出的情況下,會(huì)由于主電路電纜的電壓下降而導(dǎo)致電機(jī)的轉(zhuǎn)矩下降。5)線距離最長(zhǎng)為500米,尤其長(zhǎng)距離布線,由于布線寄生電容所產(chǎn)生的沖擊電流會(huì)引起過(guò)電流保護(hù)動(dòng)作,輸出端連接的設(shè)備可能運(yùn)行異?;虬l(fā)生故障。因此,最大布線距離按下表所示。(當(dāng)變頻器連接兩臺(tái)以上電機(jī)時(shí),布線長(zhǎng)度不得超過(guò)500米)變頻器容量0.75KW以下2.2KW4.0KW以上非超低噪音模式300米500米500米超低噪音模式300米500米500米6)在P+,B-端子之間建議連接制動(dòng)電阻器選件。7)電磁波干擾:變頻器輸入,輸出回路中含有諧波成分,在高要求場(chǎng)合請(qǐng)?jiān)谳斎攵税惭b無(wú)線電噪音濾波

42、器,使干擾降低到最小。8)在變頻器的輸出端不要安裝電力電容,浪涌抑制器和無(wú)線電噪音濾波器。這將導(dǎo)致變頻器故障或器件損壞。9)通電或運(yùn)行后,要改變接線的操作,必須先停機(jī)后再切斷電源10分鐘以上,用萬(wàn)用表檢查電壓后進(jìn)行,斷電后一段時(shí)間內(nèi),電容上依然有危險(xiǎn)的高壓。10)接地端子必須接地。由于變頻器內(nèi)有漏電流,為了防止觸電,變頻器和電機(jī)必須接地。變頻器接地用獨(dú)立接地端子(不要用螺絲在外殼,底盤(pán)等代替)。接地電纜盡量用粗的線徑,必須等于或大于附表所示標(biāo)準(zhǔn),接地線盡量靠近變頻器,接地線愈短愈好。在變頻器端接地的電機(jī),用四芯電纜中的其中一接地,規(guī)格同輸入線纜。2.4.4 變頻器主回路端子排:0.4KW-3.

43、0KW,單相系列:P+PBLNUVWPE0.4KW-5.5KW,三相系列:P+PBRSTUVWPE5.5KW以上,三相系列:P-P+PBRSTUVWPE注:不同機(jī)型可能有差異,請(qǐng)以實(shí)物為準(zhǔn)。接線時(shí)應(yīng)使變頻器端子(P+,P-)與制動(dòng)單元的端子記號(hào)相同,接錯(cuò)時(shí)會(huì)損壞變頻器。制動(dòng)單元,制動(dòng)電阻單元之間的布線距離應(yīng)在5米以內(nèi),即使用變絞線也不能超過(guò)10米。如果制動(dòng)單元內(nèi)的晶體管被損壞(短路),電阻將非常熱,導(dǎo)致起火。因此,在變頻器的輸入端安裝電磁接觸器,可在故障時(shí)切斷電源。1.電纜必須是750 C銅線。2.按一定力度擰緊螺絲。沒(méi)有擰緊會(huì)導(dǎo)致短路或誤動(dòng)作,擰過(guò)頭會(huì)造成螺絲和端子排損壞,也會(huì)導(dǎo)致短路或誤動(dòng)

44、作。控制回路接線1)端子“COM”為控制信號(hào)的公共端,請(qǐng)不要將公共端接地。2)控制回路端子的接線應(yīng)使用屏蔽或雙絞線,而且必須與主回路,強(qiáng)電回路分開(kāi)布線。3)由于控制回路的頻率輸入信號(hào)是微小電流,所以在接點(diǎn)輸入的場(chǎng)合,為了防止接觸不良,請(qǐng)使用兩個(gè)并排的接點(diǎn)或使用雙生接點(diǎn)。4)控制回路建議用0.75平方毫米的電纜接線。5)控制回路不能輸入高壓電,否則會(huì)損壞變頻器2.46變頻器控制回路端子排: 專用機(jī)型:COMX1X2X3X4X5X6COM12VY2AY2BY1AY1BY1C通用機(jī)型:10VAVICOMACIAFMY2AY2BY1AY1BY1CCOMX1X2X3X4X5X6X7X8+12V注:不同機(jī)

45、型可能有差異,請(qǐng)以實(shí)物為準(zhǔn)。第三章 運(yùn)行操作本章提供產(chǎn)品的基本“運(yùn)行操作”說(shuō)明,使用設(shè)備前請(qǐng)仔細(xì)閱讀本章的內(nèi)容。3.1操作面板操作面板是人機(jī)溝通的接口,是由按鍵部分和顯示部分組成,按鍵供用戶輸入控制指令,顯示部分則顯示參數(shù)資料和不同的運(yùn)行狀態(tài)。其外形如下圖所示:32操作鍵盤(pán)說(shuō)明符號(hào)按鍵名稱功能說(shuō)明運(yùn)行鍵按此鍵變頻器開(kāi)始運(yùn)行,若設(shè)定為外部端子控制時(shí),按此鍵無(wú)效。反轉(zhuǎn)啟動(dòng)鍵按此鍵變頻器反裝運(yùn)行,若設(shè)定為外部端子控制時(shí)或“P067”設(shè)定為0時(shí),不能反轉(zhuǎn)運(yùn)行。停止/復(fù)位鍵按此鍵變頻器停止運(yùn)行,若設(shè)定為外部端子控制時(shí),按此鍵無(wú)效(有效)。故障報(bào)警后,按此鍵系統(tǒng)復(fù)位。設(shè)置鍵按此鍵即可進(jìn)入功能設(shè)置狀態(tài),修改

46、完畢,按此鍵退出功能設(shè)置狀態(tài)。確認(rèn)在設(shè)置狀態(tài)下按此鍵確認(rèn)功能代碼,參數(shù)內(nèi)容修改后,再按此鍵,將修改過(guò)的資料保存;在待機(jī)狀態(tài)或運(yùn)行狀態(tài)下按此鍵可依次顯示直流電壓、輸出電流、溫度等,具體參見(jiàn)3.3顯示內(nèi)容說(shuō)明增加鍵按此鍵使功能代碼、參數(shù)資料數(shù)值增加。在運(yùn)行或待機(jī)狀態(tài)下按此鍵增大運(yùn)行頻率。減少鍵在設(shè)置狀態(tài)下,按此鍵使功能代碼,參數(shù)在運(yùn)行或待機(jī)狀態(tài)下按此鍵減少運(yùn)行頻率。顯示/移位鍵在設(shè)置狀態(tài)下修改參數(shù)資料時(shí),可進(jìn)行位移。在待機(jī)狀態(tài)下(P025=1)按此鍵執(zhí)行點(diǎn)動(dòng)功能。面板編碼器(非標(biāo)配)當(dāng)(P064= ),用以調(diào)節(jié)變頻器運(yùn)行頻率。相當(dāng)于加、減鍵33顯示內(nèi)容說(shuō)明顯示內(nèi)容狀態(tài)說(shuō) 明FWD亮表示馬達(dá)正轉(zhuǎn)狀態(tài)

47、REV亮表示馬達(dá)反轉(zhuǎn)狀態(tài)STOP亮表示馬達(dá)停止?fàn)顟B(tài)顯示內(nèi)容代碼功 能H給定頻率F輸出頻率A輸出電流U母線電壓u輸出電壓r電機(jī)轉(zhuǎn)速yPID給定量LPID反饋量J當(dāng)前計(jì)數(shù)值d工廠測(cè)試保留34參數(shù)修改方法如果需要修改參數(shù),首先要進(jìn)入需要修改的功能碼,然后進(jìn)行參數(shù)值重新設(shè)定,具體步驟如下:順序操作說(shuō)明1按 鍵進(jìn)入?yún)?shù)設(shè)置狀態(tài),驅(qū)動(dòng)器顯示當(dāng)前的參數(shù)號(hào),例如“P000”;2按 鍵調(diào)整到所需的參數(shù)號(hào),例如“P087”;3按 鍵驅(qū)動(dòng)器顯示當(dāng)前參數(shù)的值,例如“0”;4按 鍵調(diào)整到所需的值,例如“101”;5按 鍵確認(rèn)此操作,存儲(chǔ)資料;6按 鍵退出設(shè)置狀態(tài),回到待機(jī)或運(yùn)行狀態(tài)注意:1: 按下"ESC&q

48、uot;進(jìn)入?yún)?shù)設(shè)置狀態(tài),若按住"ESC"保持3秒以上再釋放,進(jìn)入特殊模式只能顯示和修改非出廠值參數(shù).2:在設(shè)置參數(shù)的時(shí)候,只要按"ESC"鍵便可退出設(shè)置參數(shù)狀態(tài),回到待機(jī)模式。35試運(yùn)行運(yùn)行前的重點(diǎn)檢查 是否接錯(cuò)線,尤其應(yīng)檢查一下電源是否誤接在端子上;請(qǐng)務(wù)必注意:電源應(yīng)由(L.N)端子輸入。 在變頻器基板上及配線端子上是否殘留有易引起短路的金屬屑或?qū)Ь€; 螺絲是否緊鎖、接插件是否松動(dòng); 輸出部分是否發(fā)生短路或?qū)Φ囟搪?。試運(yùn)行方法由于FC300系列變頻器的控制方法在出廠前已設(shè)定為操作器操作方式,故試運(yùn)行時(shí),可以用操作鍵盤(pán)點(diǎn)動(dòng)鍵來(lái)進(jìn)行,一般試運(yùn)行可以用5.

49、0Hz進(jìn)行。第四章:功能參數(shù)說(shuō)明序號(hào)功 能功 能 說(shuō) 明出廠值P000變頻器機(jī)種代碼識(shí)別設(shè)定范圍:0,0.75KW/220V; 1,0.75KW/380V;2,1.5KW/220V; 3,1.5KW/380V;4,2.2KW/220V; 5,2.2KW/380V;6, 3.0KW/220V; 7,3.0KW/380V;8,3.7KW/220V; 9,3.7KW/380V;10,5.5KW/220V; 11,5.5KW/380V;12,7.5KW/220V; 13,7.5KW/380V;14,11KW/220V; 15,11KW/380V;16,15KW/220V; 17,15KW/380V;1

50、8,18.5KW/220V; 19,18.5KW/380V;工廠設(shè)定,僅供讀取。P001電機(jī)額定電流設(shè)定范圍:20110%變頻器額定電流。按實(shí)際使用電機(jī)額定電流設(shè)定。驅(qū)動(dòng)多臺(tái)電機(jī)時(shí),將不能保護(hù)電機(jī),這時(shí)請(qǐng)為各電機(jī)安裝熱保護(hù)繼電器。依機(jī)種而定P002電機(jī)額定電壓設(shè)定范圍:50-460V。按實(shí)際使用電機(jī)額定電壓設(shè)定。220V(380V)P003電機(jī)額定頻率設(shè)定范圍:20.01000.0Hz按實(shí)際使用電機(jī)額定頻率設(shè)定。50.0HzP004電機(jī)空載電流設(shè)定范圍:20%-50%電機(jī)空載電流與電機(jī)額定電流的比值,會(huì)影響轉(zhuǎn)差補(bǔ)償?shù)牧俊?0P005保留P006保留P007V/F最低輸出電壓設(shè)定范圍:0-30%

51、(依機(jī)種而定)此參數(shù)設(shè)定V/F曲線的最低啟動(dòng)電壓值。依機(jī)種而定P008保留P009保留P010保留P011保留P012啟動(dòng)頻率設(shè)定范圍:1.0Hz最高操作頻率變頻器啟動(dòng)時(shí),由此頻率向目標(biāo)頻率加速。若此值設(shè)定過(guò)大,可能導(dǎo)致過(guò)電流保護(hù)動(dòng)作。1.0P013啟動(dòng)延時(shí)設(shè)定范圍:0.0600.0S變頻器啟動(dòng)時(shí),按啟動(dòng)頻率輸出,維持此設(shè)定的時(shí)間后向目標(biāo)頻率加速。此功能用于改善電機(jī)的啟動(dòng)特性,以保證電機(jī)在設(shè)定時(shí)間內(nèi)能完全啟動(dòng)。0.0P014停機(jī)方式設(shè)定范圍:0,減速后,直流制動(dòng);1,自由停機(jī)。此功能用于選擇電機(jī)的停機(jī)方式。當(dāng)選擇減速停機(jī)時(shí),變頻器接到停止命令后,電機(jī)減速到直流制動(dòng)起始頻率P015后,再按P01

52、8直流制動(dòng)電壓和P017停機(jī)制動(dòng)時(shí)間剎車(chē)停止;當(dāng)選擇自由停機(jī)時(shí),變頻器接到停止命令后,立即切斷輸出,電機(jī)自由慣性停止;0P015直流制動(dòng)起始頻率設(shè)定范圍:1.0-1000.0Hz停機(jī)時(shí),減速到此頻率后,開(kāi)始直流制動(dòng)。3.0 HzP016啟動(dòng)前制動(dòng)時(shí)間設(shè)定范圍:0.0-600.0 秒電機(jī)開(kāi)始啟動(dòng)時(shí),先按此時(shí)間進(jìn)行直流制動(dòng),之后向目標(biāo)頻率加速。0.0秒P017停機(jī)制動(dòng)時(shí)間設(shè)定范圍:0.0-600.0秒0.0秒P018直流制動(dòng)電壓設(shè)定范圍:0-30%(依機(jī)種而定)直流制動(dòng)時(shí)輸出的電壓,設(shè)定此參數(shù)時(shí),務(wù)必由小慢慢增大,直到得到足夠的制動(dòng)轉(zhuǎn)矩。1P019保留P020保留P021最高頻率設(shè)定范圍:最低操作

53、頻率1000.0Hz設(shè)定電機(jī)允許的最高的頻率。所有可操作的頻率都受此頻率限制。60.0HzP022最低操作頻率設(shè)定范圍:0.0 Hz最高操作頻率設(shè)定可操作的最低頻率。0.0HzP023最低輸出頻率設(shè)定范圍:0.0 Hz最高操作頻率設(shè)定電機(jī)可容許的變頻器最低輸出頻率。若運(yùn)行頻率設(shè)定低于此頻率時(shí),變頻器停止輸出。1.0HzP024保留P025鍵盤(pán)點(diǎn)動(dòng)控制設(shè)定范圍:0,禁止鍵盤(pán)點(diǎn)動(dòng)操作;1,允許鍵盤(pán)點(diǎn)動(dòng)操作。1P026點(diǎn)動(dòng)頻率設(shè)定范圍:最低操作頻率最高頻率設(shè)定變頻器接收到點(diǎn)動(dòng)指令時(shí),輸出的頻率值。5.0HzP027點(diǎn)動(dòng)相關(guān)參數(shù)此參數(shù)為四位十六進(jìn)制數(shù)D3、D2、D1、D0,分別代表不同功能。D0,點(diǎn)動(dòng)

54、方向控制:0, 正轉(zhuǎn);1, 反轉(zhuǎn);2(或其它),可正反轉(zhuǎn);D1,點(diǎn)動(dòng)加減速時(shí)間選擇:1-4,分別對(duì)應(yīng)第一到第四加減速時(shí)間;0(或其它),由外部控制信號(hào)選擇;0002P028保留P029保留P030第一頻率設(shè)定范圍:最低操作頻率最高頻率當(dāng)速度命令(P064)為0時(shí),此頻率作為第一速度參與運(yùn)行。此參數(shù)可直接通過(guò)操作面板鍵修改,電源關(guān)閉時(shí)可自動(dòng)記憶。50.0HzP031第二頻率設(shè)定范圍:最低操作頻率最高頻率2.0HzP032第三頻率設(shè)定范圍:最低操作頻率最高頻率3.0HzP033第四頻率設(shè)定范圍:最低操作頻率最高頻率4.0HzP034第五頻率設(shè)定范圍:最低操作頻率最高頻率5.0HzP035第六頻率設(shè)

55、定范圍:最低操作頻率最高頻率6.0HzP036第七頻率設(shè)定范圍:最低操作頻率最高頻率7.0HzP037第八頻率設(shè)定范圍:最低操作頻率最高頻率8.0HzP038第一加速時(shí)間設(shè)定范圍:0.13000.0秒此參數(shù)用于設(shè)定變頻器輸出頻率從0上升到最高頻率所需的時(shí)間。10.0P039第一減速時(shí)間設(shè)定范圍:0.13000.0秒此參數(shù)用于設(shè)定變頻器輸出頻率從最高頻率下降到0所需的時(shí)間。10.0P040第二加速時(shí)間設(shè)定范圍:0.13000.0秒10.0P041第二減速時(shí)間設(shè)定范圍:0.13000.0秒10.0P042第三加速時(shí)間設(shè)定范圍:0.13000.0秒10.0P043第三減速時(shí)間設(shè)定范圍:0.13000

56、.0秒10.0P044第四加速時(shí)間設(shè)定范圍:0.13000.0秒10.0P045第四減速時(shí)間設(shè)定范圍:0.13000.0秒10.0P046保留P047保留P048頻率記憶設(shè)定范圍:0,不記憶;1,記憶;2,記憶啟動(dòng)前頻率;設(shè)定停電后第一頻率(P030)是否記憶。1P049掉電處理設(shè)定范圍:0,報(bào)欠壓故障,并鎖定;1,報(bào)欠壓故障,電源恢復(fù)后自動(dòng)復(fù)位,不啟動(dòng);2,當(dāng)接近欠壓時(shí)減速停機(jī)。3,保留4,保留設(shè)定停電后以及重新上電時(shí),變頻器的動(dòng)作。0P050保留P051保留P052保留P053模擬輸出選擇設(shè)定范圍:0,模擬變頻器的輸出頻率,0最高頻率對(duì)應(yīng)010V;1,模擬變頻器的輸出電流,02倍變頻器額定

57、電流對(duì)應(yīng)010V;此功能用于在AFM和COM端子之間接一個(gè)直流電壓表或其它設(shè)備,用以對(duì)變頻器的輸出頻率、輸出電流進(jìn)行遠(yuǎn)方監(jiān)視。AFM端子最高輸出電壓為10V。0P054最小模擬量對(duì)應(yīng)的輸出設(shè)定范圍:0.003.00V設(shè)定最小模擬量(0Hz或0A)時(shí)端子信號(hào)的大小。0.0P055最大模擬量對(duì)應(yīng)的輸出設(shè)定范圍:5.0020.00V設(shè)定最大模擬量(最高頻率或2倍變頻器額定電流)時(shí)端子信號(hào)的大小。注意:此參數(shù)用于修正模擬輸出的大小,AFM端子實(shí)際最高輸出電壓為10V。10.00P056開(kāi)機(jī)顯示選擇設(shè)定范圍:0,頻率(H,F(xiàn));1,電機(jī)電流(A);2,母線電壓(U);3,輸出電壓(u);4,近似的機(jī)械速

58、度=輸出頻率*轉(zhuǎn)速頻率比(r);5,PID給定量(y);6,PID反饋量(L);7,計(jì)數(shù)值(J);8, 工廠測(cè)試保留(d);0P057轉(zhuǎn)速頻率比設(shè)定范圍:0.01100.00此功能用于設(shè)定速度顯示值與運(yùn)行頻率的比值,從而使速度顯示值與實(shí)際速度相符。30.00P058載波頻率設(shè)定范圍:0-5分別對(duì)應(yīng)3K,5K,7K,9K,11K,13K載波頻率越高,電機(jī)噪聲越低,電磁干擾越大,變頻器發(fā)熱越大,漏電流增大,效率下降。載波頻率越低,則與上述相反。1P059任意頻率到達(dá)設(shè)定設(shè)定范圍:0.01000.0Hz當(dāng)變頻器輸出頻率大于等于本設(shè)定值時(shí),變頻器可通過(guò)多功能輸出端子進(jìn)行信號(hào)輸出。0.0HzP060保留

59、P061跳躍頻率起點(diǎn)用于避開(kāi)機(jī)械共振點(diǎn)。20.0P062跳躍頻率寬度用于避開(kāi)機(jī)械共振點(diǎn)。0.0P063欠壓保護(hù)電壓設(shè)定范圍:220V:150-250VDC;380V:300-450VDC。170(320)P064頻率指令來(lái)源設(shè)定設(shè)定范圍:0操作面板數(shù)字設(shè)定;1AVI端子0-10V設(shè)定;2ACI端子4-20mA設(shè)定;3操作面板數(shù)字設(shè)定,若從AVI端子偵測(cè)到0-10V信號(hào)自動(dòng)切換為4;4AVI端子0-10V設(shè)定,當(dāng)AVI信號(hào)為0時(shí),若偵測(cè)到面板、操作自動(dòng)切換為3;3P065運(yùn)行指令來(lái)源設(shè)定設(shè)定范圍:0操作面板控制(正轉(zhuǎn)啟動(dòng)、反轉(zhuǎn)啟動(dòng)、停止);1外部端子控制(正轉(zhuǎn)/停止、反轉(zhuǎn)/停止);2外部端子控制

60、(啟動(dòng)/停止、反轉(zhuǎn)/正轉(zhuǎn));3外部端子控制(正轉(zhuǎn)啟動(dòng)、反轉(zhuǎn)啟動(dòng)、停止(常閉);4外部端子控制(正轉(zhuǎn)啟動(dòng)、反轉(zhuǎn)啟動(dòng)、停止(常開(kāi));5以上0-3自動(dòng)適應(yīng);此功能用于選擇變頻器啟動(dòng)、停止的控制方式。以下說(shuō)明假設(shè)X1端子設(shè)定為正轉(zhuǎn)、X2端子設(shè)定為反轉(zhuǎn)、X3端子設(shè)定為停止。當(dāng)選擇操作面板控制(0)時(shí),外部端子控制無(wú)效,由操作面板上正轉(zhuǎn)啟動(dòng)鍵RUN、反轉(zhuǎn)啟動(dòng)鍵REV、停止鍵STOP來(lái)控制電機(jī)啟動(dòng)和停止。當(dāng)選擇外部端子控制(1)時(shí),X1(正轉(zhuǎn))與COM接通正轉(zhuǎn)啟動(dòng),斷開(kāi)停止;X2(反轉(zhuǎn))與COM接通反轉(zhuǎn)啟動(dòng),斷開(kāi)停止;當(dāng)選擇外部端子控制(2)時(shí),X1(正轉(zhuǎn))與COM接通啟動(dòng),斷開(kāi)停止;X2(反轉(zhuǎn))決定運(yùn)行的

61、方向,當(dāng)X2與COM接通時(shí)為反轉(zhuǎn),斷開(kāi)時(shí)為正轉(zhuǎn);當(dāng)選擇外部端子控制(3)時(shí),X3(停止)與COM接停止按鈕常閉觸點(diǎn),X1(正轉(zhuǎn))與COM接正轉(zhuǎn)按鈕常開(kāi)觸點(diǎn),X2(反轉(zhuǎn))與COM接反轉(zhuǎn)按鈕常開(kāi)觸點(diǎn);當(dāng)選擇外部端子控制(4)時(shí),X3(停止)與COM接停止按鈕常開(kāi)觸點(diǎn),X1(正轉(zhuǎn))與COM接正轉(zhuǎn)按鈕常開(kāi)觸點(diǎn),X2(反轉(zhuǎn))與COM接反轉(zhuǎn)按鈕常開(kāi)觸點(diǎn);當(dāng)選擇0-3自動(dòng)適應(yīng)(5)時(shí),變頻器按0-3均可工作。注意:X1,X2都與COM接通時(shí),電機(jī)反轉(zhuǎn)啟動(dòng)。特別提示:在可能導(dǎo)致人身安全、生產(chǎn)損失或設(shè)備損壞的情況下,務(wù)必正確設(shè)置此參數(shù),以防意外。5P066轉(zhuǎn)向控制設(shè)定范圍:0, 正轉(zhuǎn),無(wú)論運(yùn)行命令為正轉(zhuǎn)還是反轉(zhuǎn)

62、,電機(jī)輸出正轉(zhuǎn);1, 反轉(zhuǎn),無(wú)論運(yùn)行命令為正轉(zhuǎn)還是反轉(zhuǎn),電機(jī)輸出反轉(zhuǎn);2, 可正反轉(zhuǎn)。若運(yùn)行命令為正轉(zhuǎn)則電機(jī)輸出正轉(zhuǎn);若運(yùn)行命令為反轉(zhuǎn)則電機(jī)輸出反轉(zhuǎn);用于設(shè)定電機(jī)的運(yùn)行方向,停電后自動(dòng)記憶。正反轉(zhuǎn)觸發(fā)功能會(huì)改變此參數(shù)。P067反轉(zhuǎn)控制設(shè)定范圍:0,禁止電機(jī)反轉(zhuǎn);1,允許電機(jī)反轉(zhuǎn);2,允許電機(jī)反轉(zhuǎn),且允許鍵盤(pán)反轉(zhuǎn)啟動(dòng);用于限制反轉(zhuǎn),在某些不允許電機(jī)反轉(zhuǎn)的場(chǎng)合, 應(yīng)設(shè)置此參數(shù)為0,以防意外。1P068保留P069保留P070特殊功能2工廠保留,用戶請(qǐng)謹(jǐn)慎更改。此參數(shù)為四位十六進(jìn)制數(shù)D3、D2、D1、D0,分別代表不同功能。D0過(guò)載,兩線直流制動(dòng):0,無(wú)效;1,有效。D1,多段速指令同時(shí)附帶正轉(zhuǎn)指令

63、:0,不附帶;1,附帶。D2,AVI,ACI模擬正反轉(zhuǎn):,無(wú)效;,有效>50%為正轉(zhuǎn)。D3,操作面板編碼器增量自動(dòng)加速控制:設(shè)置越小,加速越快。0x4000P071故障記錄10,無(wú)故障1,嚴(yán)重過(guò)流(HoC)2,過(guò)流(oC)3,過(guò)壓(oU)4,欠壓(LU)5,過(guò)載(oL)6,過(guò)熱(oH)7,外部故障(EF)8,存儲(chǔ)器錯(cuò)(EEP)9,參數(shù)出錯(cuò)(dEr)10,CPU故障(CPU)11,代碼錯(cuò)(CodE)12,輸入缺相(LP)13,輸出缺相(oP)14,保留0(只讀)注:故障記錄不可修改,因此出廠時(shí)可能留下測(cè)試記錄。P072故障記錄2( 同上 )0P073故障記錄3( 同上 )0P074累計(jì)開(kāi)機(jī)

64、時(shí)間(天)(只讀)P075保留P076保留P077保留P078保留P079保留P080保留P081保留P082保留P083保留P084保留P085保留0P086用戶密碼設(shè)定范圍:0-65535。0:無(wú)效;65535:無(wú)效;當(dāng)未設(shè)置密碼時(shí),將P086設(shè)定為一個(gè)新密碼,之后將P087設(shè)置為2,密碼即生效;當(dāng)已設(shè)置密碼時(shí),必須在P086輸入正確密碼,方可更改參數(shù),此時(shí)若將P087設(shè)置為3,密碼即被清除;0P087特殊操作設(shè)定此參數(shù),可執(zhí)行一些特殊的操作序列,操作完成后自動(dòng)恢復(fù)為0,不會(huì)記憶。設(shè)定范圍:0,無(wú)操作;1,恢復(fù)出廠值;2,記憶用戶密碼;3,清除用戶密碼;4,上傳參數(shù);5,下載參數(shù);(注意:

65、相同軟件版本才能執(zhí)行下載;在不同的功率規(guī)格之間拷貝,需用戶自行考慮兼容性)其它:保留,不可任意設(shè)置;0P088制動(dòng)電阻放電起始電壓設(shè)定范圍:220V變頻器:350400V380V變頻器:650720V360V或660VP089防過(guò)壓響應(yīng)點(diǎn)設(shè)定范圍:220V變頻器:350420V380V變頻器:650760V380V或730VP090防過(guò)流響應(yīng)點(diǎn)設(shè)定范圍:100190%電機(jī)額定電流150P091X1功能選擇設(shè)定范圍:0,無(wú)作用;1,多段速一;(注3)2,多段速二;(注3)3,多段速三;(注3)4,頻率上升;5,頻率下降;6,正向點(diǎn)動(dòng);7,反向點(diǎn)動(dòng);8,正轉(zhuǎn);9,反轉(zhuǎn);10,正轉(zhuǎn)觸發(fā);11,反轉(zhuǎn)觸

66、發(fā);12,停止;13,自由停機(jī);14,強(qiáng)制停機(jī);15,強(qiáng)制反轉(zhuǎn);16,計(jì)數(shù)器清零;17,計(jì)數(shù)器輸入;18,程序運(yùn)行復(fù)位;19,外部故障;20,外部復(fù)位;21,加減速時(shí)間選擇一;(注4)22,加減速時(shí)間選擇二;(注4)23,加減速暫停;24,保留;8P092X2功能選擇( 同上 )9P093X3功能選擇( 同上 )12P094X4功能選擇( 同上 )6P095X5功能選擇( 同上 )1P096X6功能選擇( 同上 )2P097X7功能選擇( 同上 )3P098X8功能選擇( 同上 )19P099保留P100保留P101Y1功能選擇設(shè)定范圍:0,無(wú)作用;1,運(yùn)行中;2,目標(biāo)頻率到達(dá);3,任意頻率到達(dá);4,故障;5,欠壓;6,計(jì)數(shù)到;7,計(jì)數(shù)到預(yù)警;8,停止中;9,電機(jī)換向延時(shí);4P102Y2功能選擇( 同上 )4P103Y3功能選擇( 同上 )4P104保留P105

溫馨提示

  • 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。

評(píng)論

0/150

提交評(píng)論