版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡介
1、山東建筑大學(xué)畢業(yè)設(shè)計(jì)說明書目 錄摘要 ···············································
2、;······················· ABSTRACT ·························&
3、#183;····································· 1 前 言 ···········
4、··················································
5、·······1 2 工程概況2.1 原始資料········································
6、183;························22.2 計(jì)算參數(shù)························
7、;·········································22.2.1 室外計(jì)算參數(shù) ······
8、83;·················································
9、83;22.2.2 室內(nèi)計(jì)算參數(shù)···············································
10、183;··········22.2.3 其他設(shè)計(jì)參數(shù)·····································&
11、#183;····················22.2.4 房間編號(hào)···························
12、183;··································3 3 設(shè)計(jì)方案的論證3.1 酒店綜合樓的空調(diào)特點(diǎn)···········&
13、#183;·········································43.2 方案比較······
14、3;·················································
15、3;········43.3 方案的確定········································
16、·······················73.4 風(fēng)機(jī)盤管機(jī)組的結(jié)構(gòu)和工作原理························
17、;·····················7 4 空調(diào)冷負(fù)荷計(jì)算4.1 冷負(fù)荷構(gòu)成及計(jì)算原理························
18、3;····························94.1.1 圍護(hù)結(jié)構(gòu)瞬變傳熱形成冷負(fù)荷的計(jì)算方法·················
19、83;···············104.1.2 透過玻璃窗的日射得熱引起的冷負(fù)荷······························
20、83;······104.1.3 設(shè)備散熱形成的冷負(fù)荷········································
21、83;········104.1.4 照明散熱形成的冷負(fù)荷 ······································
22、183;·········114.1.5 人體散熱形成的冷負(fù)荷·····································
23、183;···········114.2 新風(fēng)冷負(fù)荷····································
24、83;·························114.3 濕負(fù)荷 人體散濕量······················
25、································124.4 各層房間負(fù)荷計(jì)算···············
26、3;········································124.5 各房間送風(fēng)狀態(tài)的確定·······
27、·············································12I山東建筑大學(xué)畢業(yè)設(shè)計(jì)說明書4.5.1 方案 ·
28、;··················································
29、;·············124.5.2 各個(gè)房間的新風(fēng)量及新風(fēng)負(fù)荷的確定·································
30、;····134.6 制冷系統(tǒng)負(fù)荷的確定···········································
31、183;··········13 5 風(fēng)機(jī)盤管加新風(fēng)系統(tǒng)選型計(jì)算5.1 風(fēng)機(jī)盤管系統(tǒng)選型計(jì)算··································
32、··················155.2 新風(fēng)機(jī)組選型······························
33、······························17 6 空調(diào)機(jī)組的選型··················
34、·······································18 7 水系統(tǒng)的設(shè)計(jì)計(jì)算7.1空調(diào)水系統(tǒng)的確定·······
35、··················································
36、197.2空調(diào)水系統(tǒng)的布置················································
37、;·········197.3風(fēng)機(jī)盤管水系統(tǒng)水力計(jì)算······································&
38、#183;············207.3.1 基本公式···································&
39、#183;························207.3.2 各層的冷凍水供回水管路水力計(jì)算·····················
40、183;················217.3.3 空調(diào)風(fēng)機(jī)盤管水系統(tǒng)凝水管考慮·····························
41、3;··········237.3.4 風(fēng)機(jī)盤管系統(tǒng)的水系統(tǒng)····································
42、3;···········24 8 空調(diào)風(fēng)系統(tǒng)8.1 空調(diào)房間氣流組織···································
43、·····················268.2 風(fēng)口的布置···························&
44、#183;··································268.2.1 新風(fēng)入口注意事項(xiàng)············
45、83;·······································268.2.2 風(fēng)道的布置和制作要求·······
46、83;········································268.2.3 百葉送風(fēng)口的選擇步驟······
47、83;·········································268.3 風(fēng)口的選擇······
48、3;·················································
49、3;·····278.3.1 氣流組織設(shè)計(jì)計(jì)算··········································
50、··········278.3.2 新風(fēng)設(shè)計(jì)計(jì)算·····································
51、3;··················30 9 制冷機(jī)房各種設(shè)備的選擇9.1 制冷機(jī)組的選擇···························&
52、#183;······························339.1.1 機(jī)組的選型·················
53、·········································339.1.2 機(jī)組的選型計(jì)算······
54、83;···············································339.2 分水器和集水器的選
55、擇··················································
56、;··33II山東建筑大學(xué)畢業(yè)設(shè)計(jì)說明書9.2.1 分水器和集水器的構(gòu)造和用途··········································
57、;339.2.2 分水器和集水器的尺寸···············································
58、;·349.3 補(bǔ)水定壓系統(tǒng)的選型與計(jì)算··············································
59、;··359.3.1 補(bǔ)給水箱的選型和計(jì)算·············································
60、;···359.3.2 補(bǔ)給水泵的選型和計(jì)算············································
61、;····359.4 水泵的選型和計(jì)算···········································
62、83;············369.4.1 冷凍水泵的選型和計(jì)算··································
63、83;·············369.4.2 冷卻水泵的選型和計(jì)算·································
64、83;··············379.4.3 冷凍水泵配管布置·································
65、;···················389.4.3 冷卻塔選型····························
66、3;·····························38 10消聲減振方面的設(shè)計(jì)考慮10.1概述·················
67、··················································
68、·39 10.2消聲設(shè)備選型···············································
69、;·············39 10.3空調(diào)裝置的防振··································
70、83;·······················39 11管道保溫設(shè)計(jì)的設(shè)計(jì)考慮11.1保溫管道防結(jié)露······················
71、····································40 11.2保溫材料的選用···········
72、3;··············································40 11.3保溫度材料的經(jīng)濟(jì)厚度·
73、;··················································
74、;·40 12 結(jié)論···············································
75、83;····················41 謝辭····························
76、3;··········································42 參考文獻(xiàn)······
77、83;·················································
78、83;··········43 附錄 ······································
79、83;·······························44 附錄1冷負(fù)荷匯總················
80、3;···········································44 附錄2熱負(fù)荷的計(jì)算····
81、3;·················································
82、3;···45 附錄3管路水力計(jì)算············································
83、3;·············49III山東建筑大學(xué)畢業(yè)設(shè)計(jì)說明書摘 要本設(shè)計(jì)為上海華信國際大酒店空調(diào)工程設(shè)計(jì),本人負(fù)責(zé)地下一層和四層部分。通過方案比較,在負(fù)荷計(jì)算的基礎(chǔ)上,采用了風(fēng)機(jī)盤管加新風(fēng)和全空氣兩種空調(diào)系統(tǒng)形式。風(fēng)機(jī)盤管為臥式暗裝,新風(fēng)不承擔(dān)室內(nèi)負(fù)荷,室內(nèi)回風(fēng)與新風(fēng)混合后經(jīng)雙層百葉風(fēng)口送出;全空氣系統(tǒng)為一次回風(fēng)系統(tǒng),室內(nèi)送風(fēng)采用側(cè)送風(fēng)方式,風(fēng)口為雙層百葉風(fēng)口。新風(fēng)從墻洞或新風(fēng)豎井引入,再由機(jī)房的新風(fēng)機(jī)組集中處理供應(yīng)。冷凍水由地下室的冷凍機(jī)房供應(yīng),采用了閉式異
84、程兩管制水系統(tǒng)。水管用泡沫橡塑保溫,風(fēng)管采用離心玻璃棉。設(shè)計(jì)工程中考慮了消聲、減振和防火排煙的措施。關(guān)鍵詞:空調(diào);風(fēng)機(jī)盤管加新風(fēng)系統(tǒng);全空氣系統(tǒng);新風(fēng)IV山東建筑大學(xué)畢業(yè)設(shè)計(jì)說明書Air Conditioning Design of Shanghai Huaxin International HotelABSTRACTThe air conditioning engineering of the -1F and 4F of Shanghai Huaxin International Hotel was designed. On the base of cooling load, heating
85、 load and moisture load calculation, primary air fan-coil system and all air system are adopted by way of technical and economic analysis. The fresh air doesnt undertake indoor load and delivers air through double deflection grille after mixing the return air in the horizontal recessed fan coil. The
86、 return air is harnessed one time by the air handling unit in the all air system and the handled air is delivered through double deflection grille by sidewall air supply. The fresh air is supplied by hole or shaft and handled by the fresh air handling unit. The chilled water which is a closed two-pi
87、pe direct return water system is supplied by the refrigerating plant room. The thermal insulation material of water pipe and air duct are foam plastics and centrifugal glass wool respectively. Measures of noise elimination, damp, fire prevention and smoke extraction is considered during the design.
88、Key Words: air conditioning; primary air fan-coil system; all air system; fresh airV山東建筑大學(xué)畢業(yè)設(shè)計(jì)說明書1 前 言隨著我國國民經(jīng)濟(jì)水平的不斷提高,建筑業(yè)也在持續(xù)穩(wěn)定地向前發(fā)展。和前幾年建筑業(yè)的發(fā)展相比,目前的發(fā)展商將眼光放的更遠(yuǎn),他們不再片面的追求容積率及如何將開發(fā)成本降得越低越好,而是更多的考慮以人為本,開發(fā)真正舒適度高、建筑質(zhì)量高的居住及商用建筑。隨著中國加入世貿(mào)及承辦2008年奧運(yùn)會(huì),中國將向全世界全面開放。為了適應(yīng)國際貿(mào)易、旅游、及城市建設(shè)迅速發(fā)展的需要,高層建筑的發(fā)展不會(huì)停留在過去的發(fā)展水平,特
89、別是對(duì)建筑物內(nèi)的空氣品質(zhì)及舒適程度的要求也會(huì)越來越高。新建的大中商業(yè)建筑紛紛安裝了空調(diào)系統(tǒng),以提高商場(chǎng)的檔次,吸引更多的顧客。各大城市中頻頻展開的“商戰(zhàn)”更加速了空調(diào)系統(tǒng) 在商業(yè)建筑中的普及。商業(yè)建筑不斷的增多,以及人們對(duì)室內(nèi)空氣的溫濕度、潔凈度和空氣品質(zhì)問題越來越重視。由于能源的緊缺,節(jié)能問題越來越引起人們的重視。因此迫切需要為商業(yè)建筑物安裝配置節(jié)能、健康、舒適的中央空調(diào)系統(tǒng)來滿足人們對(duì)高生活水平的追求。- 1 -山東建筑大學(xué)畢業(yè)設(shè)計(jì)說明書2 工程概況2.1 原始資料北京華信國際大酒店是一個(gè)由酒店、餐飲、會(huì)議、商務(wù)、商貿(mào)的部分組成的五星級(jí)酒店。該建筑地下一層為中央空調(diào)機(jī)房及停車場(chǎng),地上一七層
90、為會(huì)議室、客房、娛樂室等。在四層與五層之間為為設(shè)備層,冷卻塔等設(shè)于本層??偨ㄖ叨?0.1m,建筑面積35208m²,地下建筑面積6179 m²。 2.2 計(jì)算參數(shù) 2.2.1 室外計(jì)算參數(shù)表 2.1 北京市室外氣象參數(shù)2.2.2 室內(nèi)計(jì)算參數(shù)表 2.2 各空調(diào)房間室內(nèi)計(jì)算參數(shù)2.2.3其他設(shè)計(jì)參數(shù)表2.3 照明功率密度值(w)- 2 -山東建筑大學(xué)畢業(yè)設(shè)計(jì)說明書表2.4 不同類型房間人均占有的使用面積(/人)表2.5 不同類型房間電器設(shè)備功率(w)2.2.4房間編號(hào)圖2.1 四層房間編號(hào)圖2.2 地下一層房間編號(hào)- 3 -山東建筑大學(xué)畢業(yè)設(shè)計(jì)說明書3 設(shè)計(jì)方案的論證3.1
91、酒店綜合樓的空調(diào)特點(diǎn)1)建筑特點(diǎn)該酒店的外圍護(hù)結(jié)構(gòu)多為鋼筋混凝土的框架結(jié)構(gòu),采用自重的輕型墻體材料作為外圍護(hù)結(jié)構(gòu)。大量采用玻璃幕墻,采用大面積單層玻璃幕墻加鋁合金飾板作為高層寫字樓外圍護(hù)結(jié)構(gòu)的主流,其玻璃幕墻主要為6mm或8mm厚度的熱反射鍍膜玻璃。2)使用特點(diǎn)該酒店房間類型繁多,使用時(shí)間不一致性大,管理不太方便,在選擇方案時(shí)應(yīng)充分考慮。3)空調(diào)系統(tǒng)注意事項(xiàng)a.分區(qū)問題:考慮到建筑物結(jié)構(gòu)上的差別和翻建類型的不同,可將將建筑物按防火分區(qū)分為A區(qū)和B區(qū)。b.過度季節(jié)問題:過度季節(jié)部分房間可不用冷熱源,但部分房間仍需要降溫,這時(shí)應(yīng)用室外空氣直接進(jìn)入需降溫房間降溫,即節(jié)能又簡單;或考慮采用一臺(tái)小容量的
92、制冷機(jī)。c.大空間空調(diào)形式問題:對(duì)于個(gè)別大空間可選擇取全空氣系統(tǒng)。d.特殊房間的個(gè)別控制問題:用風(fēng)機(jī)盤管系統(tǒng)以便控制。3.2方案比較表3.1 全空氣系統(tǒng)與空氣水系統(tǒng)方案比較表2- 4 -山東建筑大學(xué)畢業(yè)設(shè)計(jì)說明書續(xù)表3.1- 5 -山東建筑大學(xué)畢業(yè)設(shè)計(jì)說明書表3.2 風(fēng)機(jī)盤管+新風(fēng)系統(tǒng)的特點(diǎn)表表3.3 風(fēng)機(jī)盤管的新風(fēng)供給方式表12- 6 -山東建筑大學(xué)畢業(yè)設(shè)計(jì)說明書本設(shè)計(jì)為酒店的空調(diào)系統(tǒng)設(shè)計(jì),系統(tǒng)的選定應(yīng)注意檔次和安全的要求,按負(fù)擔(dān)室內(nèi)空調(diào)負(fù)荷所用的介質(zhì)來分類可選擇四種系統(tǒng)全空氣系統(tǒng)、空氣水系統(tǒng)、全水系統(tǒng)、冷劑系統(tǒng)。全空氣系統(tǒng)分一次回風(fēng)式系統(tǒng)和二次回風(fēng)式系統(tǒng),該系統(tǒng)是全部由處理過的空氣負(fù)擔(dān)室內(nèi)
93、空調(diào)冷負(fù)荷和濕負(fù)荷;空氣水系統(tǒng)分為再熱系統(tǒng)和誘導(dǎo)器系統(tǒng)并用、全新風(fēng)系統(tǒng)和風(fēng)機(jī)盤管機(jī)組系統(tǒng)并用;全水系統(tǒng)即為風(fēng)機(jī)盤管機(jī)組系統(tǒng),全部由水負(fù)擔(dān)室內(nèi)空調(diào)負(fù)荷,在注重室內(nèi)空氣品質(zhì)的現(xiàn)代化建筑內(nèi)一般不單獨(dú)采用,而是與新風(fēng)系統(tǒng)聯(lián)合運(yùn)用;冷劑系統(tǒng)分單元式空調(diào)器系統(tǒng)、窗式空調(diào)器系統(tǒng)、分體式空調(diào)器系統(tǒng),它是由制冷系統(tǒng)蒸發(fā)器直接放于室內(nèi)消除室內(nèi)的余熱和余濕。對(duì)于較大型公共建筑,建筑內(nèi)部的空氣品質(zhì)級(jí)別要求較高,全水系統(tǒng)和冷劑系統(tǒng)只能消除室內(nèi)的余熱和余濕,不能起到改善室內(nèi)空氣品質(zhì)的作用,所以全水系統(tǒng)和冷劑系統(tǒng)在本次的建筑空調(diào)設(shè)計(jì)時(shí)不宜采用。終上所述,擬采用風(fēng)機(jī)盤管加新風(fēng)系統(tǒng),風(fēng)機(jī)盤管的新風(fēng)供給方式用單設(shè)新風(fēng)系統(tǒng),獨(dú)立供
94、給室內(nèi)。而對(duì)于餐廳、門廳等空間較大、人員較多、溫度和濕度允許值波動(dòng)范圍小的房間,擬采用全空氣系統(tǒng)。3.3方案的確定該酒店采用風(fēng)機(jī)盤管加新風(fēng)系統(tǒng)。因?yàn)樵摼频攴块g類型繁多,各房間冷熱負(fù)荷并不相- 7 -山東建筑大學(xué)畢業(yè)設(shè)計(jì)說明書同,可以個(gè)房間進(jìn)行個(gè)別的調(diào)節(jié)。每層設(shè)有新風(fēng)機(jī)組,可以由同層的新風(fēng)機(jī)組送入室內(nèi),和風(fēng)機(jī)盤管一起滿足室內(nèi)的冷熱負(fù)荷。風(fēng)機(jī)盤管空調(diào)方式,這種方式風(fēng)管小,可以降低房間層高,但維修工作量大,如果水管漏水或冷水管保溫不好而產(chǎn)生凝結(jié)水,對(duì)線槽內(nèi)的電線或其它接近樓地面的電器設(shè)備是一個(gè)威脅,因此要求確保管道安裝質(zhì)量。風(fēng)機(jī)盤管加新風(fēng)系統(tǒng)占空間少,使用也較靈活,但空調(diào)設(shè)備產(chǎn)生的振動(dòng)和噪音問題需要
95、采取切實(shí)措施予以解決。對(duì)于該系統(tǒng)所存在的缺點(diǎn),可在設(shè)計(jì)當(dāng)中根據(jù)具體的問題予以解決和彌補(bǔ)。對(duì)于空間較大的房間(比如大廳和餐廳)如果設(shè)置風(fēng)機(jī)盤管水系統(tǒng)的話會(huì)用到較多的末端設(shè)備,造成投資上的浪費(fèi),因此此類房間采用全空氣系統(tǒng)。3.4風(fēng)機(jī)盤管機(jī)組的結(jié)構(gòu)和工作原理風(fēng)機(jī)盤管機(jī)組是空調(diào)機(jī)組的末端機(jī)組之一,就是將通風(fēng)機(jī)、換熱器及過濾器等組成一體的空氣調(diào)節(jié)設(shè)備。機(jī)組一般分為立式和臥式兩種,可以按室內(nèi)安裝位置選定,同時(shí)根據(jù)室內(nèi)裝修要求可做成明裝或暗裝。風(fēng)機(jī)盤管通常與冷水機(jī)組(夏)或熱水機(jī)組(冬)組成一個(gè)供冷或供熱系統(tǒng)。風(fēng)機(jī)盤管是分散安裝在每一個(gè)需要空調(diào)的房間內(nèi)(如賓館的客房、醫(yī)院的病房、寫字樓的各寫字間等)。風(fēng)機(jī)盤
96、管機(jī)組中風(fēng)機(jī)不斷循環(huán)所在房間內(nèi)的空氣和新風(fēng),使空氣通過供冷水或供熱水的換熱器被冷卻或加熱,以保持房間內(nèi)溫度。在風(fēng)機(jī)吸風(fēng)口外設(shè)有空氣過濾器,用以過濾被吸入空氣中的塵埃,一方面改善房間的衛(wèi)生條件,另一方面也保護(hù)了換熱器不被塵埃所堵塞。換熱器在夏季可以除去房間的濕氣,維持房間的一定相對(duì)濕度。換熱器表面的凝結(jié)水滴入接水盤內(nèi),然后不斷地被排入下水道中。由于本系統(tǒng)采用風(fēng)機(jī)盤管+新風(fēng)系統(tǒng),有獨(dú)立的新風(fēng)系統(tǒng)供給室內(nèi)新風(fēng),即把新風(fēng)處理到室內(nèi)參數(shù),不承擔(dān)房間負(fù)荷。這種方案既提高了該系統(tǒng)的調(diào)節(jié)和運(yùn)轉(zhuǎn)的靈活性,且進(jìn)入風(fēng)機(jī)盤管的供水溫度可適當(dāng)提高,水管結(jié)露現(xiàn)象可以得到改善。- 8 -山東建筑大學(xué)畢業(yè)設(shè)計(jì)說明書4 空調(diào)冷
97、負(fù)荷計(jì)算4.1冷負(fù)荷構(gòu)成及計(jì)算原理4.1.1 圍護(hù)結(jié)構(gòu)瞬變傳熱形成冷負(fù)荷的計(jì)算方法具體計(jì)算見附錄11)外墻和屋面瞬變傳熱引起的冷負(fù)荷在日射和室外氣溫綜合作用下,外墻和屋面瞬變傳熱引起的逐時(shí)冷負(fù)荷可按下式計(jì)算:LQ1=F·K·tt-e W (4.1)式中:LQ1外墻和屋面瞬變傳熱引起的逐時(shí)冷負(fù)荷,W;F外墻和屋面的面積,;K外墻和屋面的傳熱系數(shù),W/(·);t計(jì)算時(shí)間,h;e維護(hù)結(jié)構(gòu)表面受到周期為24小時(shí)諧性溫度波作用,溫度波傳到內(nèi)表面的時(shí)間延遲,h;t-e溫度波的作用時(shí)間,即溫度波作用于維護(hù)結(jié)構(gòu)內(nèi)表面的時(shí)間,h;tt-e作用時(shí)刻下,維護(hù)結(jié)構(gòu)的冷負(fù)荷計(jì)算溫差,;2)
98、 內(nèi)墻,樓板等室內(nèi)傳熱維護(hù)結(jié)構(gòu)形成的瞬時(shí)冷負(fù)荷當(dāng)空調(diào)房間的溫度與相鄰非空調(diào)房間的溫度大于3時(shí),要考慮由內(nèi)維護(hù)結(jié)構(gòu)的溫差傳熱對(duì)空調(diào)房間形成的瞬時(shí)冷負(fù)荷,可按如下傳熱公式計(jì)算:LQ2=F·K·(tl s - tn) W (4.2)式中: F內(nèi)維護(hù)結(jié)構(gòu)的傳熱面積,m²;K內(nèi)維護(hù)結(jié)構(gòu)的傳熱系數(shù),W /( m²·k) ;tn 夏季空調(diào)房間室內(nèi)設(shè)計(jì)溫度,;tl s 相鄰非空調(diào)房間的平均計(jì)算溫度, 。t'l s按下式計(jì)算 t'l s = t + tl s (4.3)式中:t 夏季空調(diào)房間室外計(jì)算日平均溫度,;tl s 相鄰非空調(diào)房間的平均計(jì)算
99、溫度與夏季空調(diào)房間室外計(jì)算日平均溫度的差值,當(dāng)相鄰散熱量很少(如走廊)時(shí), tl s 取3 ,;當(dāng)相鄰散熱量在23116 W/m2時(shí), tl s取5 。- 9 -山東建筑大學(xué)畢業(yè)設(shè)計(jì)說明書3)外玻璃窗瞬變傳熱引起的冷負(fù)荷在室內(nèi)外溫差的作用下, 玻璃窗瞬變熱形成的冷負(fù)荷可按下式計(jì)算: LQ3=F·K·tt W (4.4) 式中:F外玻璃窗面積,m²;K玻璃的傳熱系數(shù),W /( m²·k) ;tt計(jì)算時(shí)刻的負(fù)荷溫差,;4.1.2 透過玻璃窗的日射得熱引起的冷負(fù)荷透過玻璃窗進(jìn)入室內(nèi)的日射得熱形成的逐時(shí)冷負(fù)荷按下式計(jì)算: LQ=F·C
100、83;xg·xd·Jj.t W (4.5) 4Z式中:F玻璃窗的面積;C玻璃窗的綜合遮擋系數(shù)C =Cs·Cn ; ZZ其中,Cs 玻璃窗的遮擋系數(shù),本設(shè)計(jì)中,6mm厚吸熱玻璃Cs =0.75;Cn 窗內(nèi)遮陽設(shè)施的遮陽系數(shù),本設(shè)計(jì)中,中間色活動(dòng)百葉簾Cn =0.6;xg窗的有效面積系數(shù);單層鋼窗,雙層鋼窗0.75;單層木窗0.7,雙層木窗0.6;xd地點(diǎn)修正系數(shù),北京為1;透過單層窗口面積的太陽輻射熱形成的冷負(fù)荷,簡稱負(fù)荷強(qiáng)度,Jj.t計(jì)算時(shí)刻時(shí),W/m2;4.1.3 設(shè)備散熱形成的冷負(fù)荷設(shè)備和用具顯熱形成的冷負(fù)荷按下式計(jì)算:LQ=QCLQ W (4.6)式中:LQ
101、設(shè)備和用具形成的冷負(fù)荷,W;Qq設(shè)備和用具的實(shí)際顯熱散熱量,W;CLQ設(shè)備和用具顯熱散熱冷負(fù)荷系數(shù);如果空調(diào)系統(tǒng)不連續(xù)運(yùn)行,則CLQ1.0。- 10 -山東建筑大學(xué)畢業(yè)設(shè)計(jì)說明書4.1.4 照明散熱形成的冷負(fù)荷根據(jù)照明燈具的類型和安裝方式的不同,其冷負(fù)荷計(jì)算式分別為:白熾燈:LQ5 =1000·N·CLQ W (4.7)熒光燈:LQ5 =1000·n1·n2 ·N·CLQ W (4.8) 式中:LQ5燈具散熱形成的冷負(fù)荷,W;N照明燈具所需功率,KW;n1鎮(zhèn)流器消耗功率系數(shù),當(dāng)明裝熒光燈的鎮(zhèn)流器裝在空調(diào)房間內(nèi)時(shí),取n11.2;當(dāng)暗裝熒
102、光燈鎮(zhèn)流器裝設(shè)在頂棚內(nèi)時(shí),可取n11.0;本設(shè)計(jì)取n11.0;n2燈罩隔熱系數(shù),當(dāng)熒光燈上部穿有小孔(下部為玻璃板),可利用自然通風(fēng)散熱與頂棚內(nèi)時(shí),取n20.50.8;而熒光燈罩無通風(fēng)孔時(shí),取n20.60.8;本設(shè)計(jì)取n20.6;CLQ照明散熱冷負(fù)荷系數(shù)。本設(shè)計(jì)照明設(shè)備為暗裝熒光燈,鎮(zhèn)流器設(shè)置在頂棚內(nèi),熒光燈罩無通風(fēng)孔,功率按照表2.3計(jì)算。4.1.5 人體散熱形成的冷負(fù)荷人體散熱引起的冷負(fù)荷計(jì)算式為:LQ6qs·n·n·CLQ +ql·n·n W (4.9)式中:LQ6人體散熱形成的冷負(fù)荷,W;qs不同室溫和勞動(dòng)性質(zhì)成年男子顯熱散熱量,W;n
103、室內(nèi)全部人數(shù);n群集系數(shù),辦公樓群集系數(shù)為0.93;CLQ人體顯然散熱冷負(fù)荷系數(shù),人體顯然散熱冷負(fù)荷系數(shù)。4.2 新風(fēng)冷負(fù)荷目前,我國空調(diào)設(shè)計(jì)中對(duì)新風(fēng)量的確定原則,仍采用現(xiàn)行規(guī)范、設(shè)計(jì)手冊(cè)中規(guī)定或推薦的原則, 各房間的新風(fēng)量按表2.2選取。夏季,空調(diào)新風(fēng)冷負(fù)荷按下式計(jì)算:CLWLW·(hW-hN) W (4.10)- 11 -山東建筑大學(xué)畢業(yè)設(shè)計(jì)說明書式中: CLW夏季新風(fēng)冷負(fù)荷,KW;LW新風(fēng)量,kg/s;hW室外空氣的焓值,kj/kg;hN室內(nèi)空氣的焓值,kj/kg。4.3 濕負(fù)荷 人體散濕量人體散濕量可按下式計(jì)算:D=n·n·w·10-3 kg/h
104、 (4.11) 式中:D人體散濕量,kg/h;n群集系數(shù),選取群集系數(shù)為0.93;w成年男子的小時(shí)散熱量,kg/(h·p);26時(shí),極輕勞動(dòng)成年男子的小時(shí)散熱量為0.109 kg/(h·p)。4.4 各層房間負(fù)荷計(jì)算具體計(jì)算見附表。4.5 各房間送風(fēng)狀態(tài)的確定4.5.1 方案終上所述,采用風(fēng)機(jī)盤管加新風(fēng)系統(tǒng),風(fēng)機(jī)盤管的新風(fēng)供給方式用單設(shè)新風(fēng)系統(tǒng),獨(dú)立供給室內(nèi)。風(fēng)機(jī)盤管加新風(fēng)系統(tǒng)的空氣處理方式有:1)新風(fēng)處理到室內(nèi)狀態(tài)的等焓線,不承擔(dān)室內(nèi)冷負(fù)荷;2)新風(fēng)處理到室內(nèi)狀態(tài)的等含濕量線,新風(fēng)機(jī)組承擔(dān)部分室內(nèi)冷負(fù)荷;3)新風(fēng)處理到焓值小于室內(nèi)狀態(tài)點(diǎn)焓值,新風(fēng)機(jī)組不僅承擔(dān)新風(fēng)冷負(fù)荷,還
105、承擔(dān)部分室內(nèi)顯熱冷負(fù)荷和全部潛熱冷負(fù)荷,風(fēng)機(jī)盤管僅承擔(dān)一部分室內(nèi)顯熱冷負(fù)荷,可實(shí)現(xiàn)等濕冷卻,可改善室內(nèi)衛(wèi)生和防止水患;4)新風(fēng)處理到室內(nèi)狀態(tài)的等溫線風(fēng)機(jī)盤管承擔(dān)的負(fù)荷很大,特別是濕負(fù)荷很大,造成衛(wèi)生問題和水患;5)新風(fēng)處理到室內(nèi)狀態(tài)的等焓線,并與室內(nèi)狀態(tài)點(diǎn)直接混合進(jìn)入風(fēng)機(jī)盤管處理。風(fēng)機(jī)盤管- 12 -山東建筑大學(xué)畢業(yè)設(shè)計(jì)說明書處理的風(fēng)量比其它方式大,不易選型。所以本設(shè)計(jì)選擇新風(fēng)處理到室內(nèi)狀態(tài)的等焓線,不承擔(dān)室內(nèi)冷負(fù)荷方案。4.5.2 各房間的新風(fēng)量及新風(fēng)負(fù)荷的確定以4B1房間為例,房間的新風(fēng)量指標(biāo)50m³/h.p;本辦公樓人員密度按25 m2/人估算; 則新風(fēng)量:Gw =50
106、5;33=1515 m³/h 1新風(fēng)負(fù)荷計(jì)算:在濕空氣的h-d圖上,根據(jù)設(shè)計(jì)地的室外空氣的夏季空調(diào)計(jì)算干球溫度tw和濕球溫度tws確定新風(fēng)狀態(tài)點(diǎn)W,得出新風(fēng)的焓h;根據(jù)室內(nèi)空氣的設(shè)計(jì)溫度t和相對(duì)濕度,確定回風(fēng)狀WN態(tài)點(diǎn)N(也就是室內(nèi)空氣設(shè)計(jì)狀態(tài)點(diǎn)),得出回風(fēng)的焓h。則夏季空調(diào)的新風(fēng)負(fù)荷按CLWNLW ·(hW-hN) W 計(jì)算。根據(jù)室內(nèi)外參數(shù)(tN=26, =60%;tw=33.6,tws=26.3)查h-d圖(見圖4.1)得hW=82.0,hN=58.4 ;h=hW-hN=82.0-58.4=23.6 KJ/Kg。則 CLW =Gw·h (4.12) 1=151
107、5×38.8×1000÷3600=12980(W)圖4.1濕空氣的h-d圖4.6 制冷系統(tǒng)負(fù)荷的確定制冷系統(tǒng)負(fù)荷Q0可按下式確定:- 13 -山東建筑大學(xué)畢業(yè)設(shè)計(jì)說明書Q0=Q·Kr·K·K·Kb KW (4.13)式中:Q空調(diào)系統(tǒng)冷負(fù)荷,KW ;Kr房間同期使用系數(shù),0.61.0 ,本設(shè)計(jì)Kr=1; Kf 冷量損失附加系數(shù),風(fēng)-水系統(tǒng)Kf=1.101.15;直接蒸發(fā)式表冷系統(tǒng)Kf=1.051.10; 本設(shè)計(jì)為風(fēng)-水系統(tǒng),Kf=1.10; K效率降低修正系數(shù),K=1.051.10;本設(shè)計(jì)K=1.05; Kb事故備用系數(shù),一般
108、不考慮備用,僅在特殊工程中才采用X臺(tái)1備用的方式。本設(shè)計(jì)不考慮備用,Kb=1.0。則本設(shè)計(jì)制冷系統(tǒng)的負(fù)荷Q0=Q·Kr·K·K·Kb=735×1×1.10×1.05×1.0 =882 KW- 14 -山東建筑大學(xué)畢業(yè)設(shè)計(jì)說明書5 風(fēng)機(jī)盤管加新風(fēng)系統(tǒng)選型計(jì)算5.1 風(fēng)機(jī)盤管系統(tǒng)選型計(jì)算1) 空氣處理方案及有關(guān)參數(shù)的查取風(fēng)機(jī)盤管的選型應(yīng)根據(jù)風(fēng)機(jī)盤管所能提供的顯熱和全熱冷負(fù)荷能滿足房間所需顯熱和全熱負(fù)荷的原則選型。設(shè)計(jì)方案為:新風(fēng)處理到室內(nèi)空氣的焓值,而風(fēng)機(jī)盤管承擔(dān)室內(nèi)人員、設(shè)備冷負(fù)荷和建筑物維護(hù)結(jié)構(gòu)負(fù)荷。4B1房間空氣
109、處理方案過程線如下圖:Wtw=33.6°CNtn=26°Chw=82.0KJ/Kgtl'(F)=18°ChN=58.4KJ/Kghl'(F)=47.5KJ/Kg圖5.1 空氣處理方案過程圖由tN=26, =60%得hN=58.4KJ/Kg,tNS=20.4;由tw=33.6,tws=26.3得hW=82.0KJ/Kg;=8403/0.5797=14495查h-d圖tNL=17.8,tN-tNL=26-17.8=8.2>8,則取送風(fēng)溫度差為t=8;則tl(F)=26-8=18,由tl(F)=18,l(F)=90%,在h-d圖上定出風(fēng)機(jī)盤管機(jī)器露
110、點(diǎn)L(F),得hl(F)=47.5 KJ/Kg。2)風(fēng)機(jī)盤管所需冷量以4B1房間為例: QF=8403W5)風(fēng)機(jī)盤管所需風(fēng)量LF= QF/1.2·(hN - hl(F)=8.403/1.2×(58.4-47.5)=0.6424m³/s=2312 m³/h6)選擇風(fēng)機(jī)盤管所選的風(fēng)機(jī)盤管要求當(dāng)進(jìn)水溫度為7時(shí),進(jìn)風(fēng)參數(shù)DB/WB=26/18.6,LF=2312 m³/h,- 15 -山東建筑大學(xué)畢業(yè)設(shè)計(jì)說明書QF=8403 W。根據(jù)所需風(fēng)量及中等風(fēng)速選型原則,選擇 奇威特公司的VCF125型盤管兩臺(tái),其但臺(tái)額定風(fēng)量為1215 m³/h,取最
111、小水量L=14.5 L/min,進(jìn)水溫度為7時(shí)查得風(fēng)機(jī)盤管的冷量為5449×0.925×2=10080W,滿足要求。故選VCF125WA的標(biāo)準(zhǔn)型風(fēng)機(jī)盤管兩臺(tái)。圖5.2 新風(fēng)與風(fēng)機(jī)盤管送風(fēng)混合后送入房間用同樣方法確定其他房間風(fēng)機(jī)盤管型號(hào),見下表:表5.1 各房間風(fēng)機(jī)盤管型號(hào)匯總表- 16 -山東建筑大學(xué)畢業(yè)設(shè)計(jì)說明書5.2 新風(fēng)機(jī)組選型表5.2 新風(fēng)機(jī)組選型表- 17 -山東建筑大學(xué)畢業(yè)設(shè)計(jì)說明書6 空調(diào)機(jī)組的選型由該棟建筑物的特點(diǎn),在各個(gè)大空間的房間分別設(shè)置全空氣系統(tǒng)荷為83700W?,F(xiàn)以四層A區(qū)為例選擇空調(diào)機(jī)組:四層A區(qū)的總冷負(fù)荷76338 W,室內(nèi)濕負(fù)荷5.08g/s,
112、室內(nèi)參數(shù)iR=55.4kJ/kg,處理過程焓濕圖見下圖(圖6.1)。Qe=76338/5.08=15027 熱濕比:WOOt =33.6°C采用機(jī)器露點(diǎn)送風(fēng),過R 點(diǎn)作線交=95%線于S。 S點(diǎn)送風(fēng)狀態(tài)點(diǎn): iS=48kJ/kgM點(diǎn)為新回風(fēng)混合狀態(tài)點(diǎn) 按新回風(fēng)比15確定。室內(nèi)空氣參數(shù): iR=55.4kJ/kg =60%t =26°CRRM100%S95%總送風(fēng)量:圖6.1 空氣處理方案過程圖 G=Q76338=10.315kg/s=30945m3/h iR-iS55.4-48新風(fēng)量GW=9750 m3/h=3.25kg/s 回風(fēng)量Gh=G-GW=7.065kg/s=211
113、95=m3/h3.25im-55.4RMGW= 得im=63.8kJ/kg10.31582-55.4GRW空調(diào)機(jī)組的總耗冷量Q0=G(im-is)=10.315×(63.8-48)=162.9根據(jù)以上數(shù)據(jù),選擇組合空調(diào)機(jī)組型號(hào)為VAQB0606,在入口空氣溫度為26,進(jìn)水為7,溫差為5的標(biāo)準(zhǔn)工況下,其性能參數(shù),(見表6.1)表6.1 組合空調(diào)機(jī)組型號(hào)為VAQB0606性能參數(shù)- 18 -山東建筑大學(xué)畢業(yè)設(shè)計(jì)說明書7 空調(diào)水系統(tǒng)設(shè)計(jì)計(jì)算7.1 水系統(tǒng)的比較、選擇空調(diào)水系統(tǒng)包括冷水系統(tǒng)和冷卻水系統(tǒng)兩個(gè)部分,它們有不同類型可供選擇。1根據(jù)以上各系統(tǒng)的特征及優(yōu)缺點(diǎn),結(jié)合本酒店情況,本設(shè)計(jì)空調(diào)
114、水系統(tǒng)選擇閉式、同程、雙管制、單式泵系統(tǒng),這樣布置的優(yōu)點(diǎn)是過渡季節(jié)只供給新風(fēng),不使用風(fēng)機(jī)盤管的時(shí)候便于系統(tǒng)的調(diào)節(jié),節(jié)約能源。7.2 空調(diào)水系統(tǒng)的布置本系統(tǒng)設(shè)計(jì)可以采用雙管制供應(yīng)冷凍水,且具有結(jié)構(gòu)簡單,初期投資小等特點(diǎn)。同時(shí)考慮到節(jié)能與管道內(nèi)清潔等問題,可以采用閉式系統(tǒng),不與大氣相接觸,管路不易產(chǎn)生污垢和腐蝕,不需要克服系統(tǒng)靜水壓頭,水泵耗電較小。- 19 -山東建筑大學(xué)畢業(yè)設(shè)計(jì)說明書由于設(shè)計(jì)屬于多層建筑,因此可以采用同程式水系統(tǒng),此系統(tǒng)除了供回水管路外,還有一根同程管,由于各并聯(lián)環(huán)路的管路總長度基本相同,各用戶盤管的水阻力大致相等,所以系統(tǒng)的水力穩(wěn)定性好,流量分配均勻,且此系統(tǒng)屬于垂直同程系統(tǒng)
115、。本設(shè)計(jì)采用的是螺桿冷水機(jī)組,機(jī)組布置在地下一層冷凍機(jī)房的方案。供水、立管均采用同程式,新風(fēng)機(jī)組和風(fēng)機(jī)盤管系統(tǒng)共用供、回水立管;各層水管也采用同程式,新風(fēng)機(jī)組和風(fēng)機(jī)盤管系統(tǒng)共用供、回水立管。定壓補(bǔ)水系統(tǒng)采用補(bǔ)水泵,置于地下一層。 7.3 風(fēng)機(jī)盤管水系統(tǒng)水力計(jì)算 7.3.1 基本公式 1)沿程阻力Pe=e· v 2·/2 g mH2O (7.1)沿程阻力系數(shù) e=0.025·L/d (7.2) 2)局部阻力水流動(dòng)時(shí)遇彎頭、三通及其他配件時(shí),因摩擦及渦流耗能而產(chǎn)生的局部阻力為:Pm=··v 2/2 g mH2O (7.3) 3)水管總阻力P=Pe+
116、Pj mH2O (7.4) 4)確定管徑dn=mm (7.5)式中:Vj冷凍水流量,m 3/s ;vj流速,m/s 。在水力計(jì)算時(shí),初選管內(nèi)流速和確定最后的流速時(shí)必須滿足以下要求:表7.2 管內(nèi)水的最大允許水流速表- 20 -山東建筑大學(xué)畢業(yè)設(shè)計(jì)說明書空調(diào)系統(tǒng)的水系統(tǒng)的管材有鍍鋅鋼管和無縫鋼管。當(dāng)管徑DN100mm時(shí)可以采用鍍鋅鋼管,其規(guī)格用公稱直徑DN表示;當(dāng)管徑DN>100mm時(shí)采用無縫鋼管,其規(guī)格用外徑×壁厚表示,一般須作二次鍍鋅。7.3.2 各層的冷凍水供回水管路水力計(jì)算水力計(jì)算的步驟:(1):選定最不利環(huán)路,給管段標(biāo)號(hào)。圖7.1 地下一層水系統(tǒng)圖圖7.2 四層水系統(tǒng)圖(2):根據(jù)個(gè)管段的冷負(fù)荷,計(jì)算各管段的流量,計(jì)算式如下:- 21 -山東建筑大學(xué)畢業(yè)設(shè)計(jì)說明書G=3600Qkg/h (7.6)4.19´1000Dt式中: Q 管段的冷負(fù)荷, W; t 供水回水的溫差,
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 2025年河南工業(yè)職業(yè)技術(shù)學(xué)院高職單招職業(yè)適應(yīng)性測(cè)試近5年常考版參考題庫含答案解析
- 2025年江西水利職業(yè)學(xué)院高職單招職業(yè)技能測(cè)試近5年??及鎱⒖碱}庫含答案解析
- 專題03 句子(第3期)
- 專題04 世界古代史(易混易錯(cuò)點(diǎn))
- 簽訂二手房買賣合同注意事項(xiàng)
- 民法租賃合同
- 安裝燈具合同范本
- 裝修工人員工勞動(dòng)合同
- 渣土運(yùn)輸工程合同
- 直播銷售策劃合同
- 2025年人教五四新版八年級(jí)物理上冊(cè)階段測(cè)試試卷含答案
- 2025新人教版英語七年級(jí)下單詞表(小學(xué)部分)
- 2025年春季1530安全教育記錄主題
- 礦山2025年安全工作計(jì)劃
- 給客戶的福利合同(2篇)
- 【高中語文】《氓》課件++統(tǒng)編版+高中語文選擇性必修下冊(cè)
- T-WAPIA 052.3-2023 無線局域網(wǎng)設(shè)備技術(shù)規(guī)范 第3部分:接入點(diǎn)和控制器
- 運(yùn)動(dòng)技能學(xué)習(xí)與控制完整
- Unit4MyfamilyStorytime(課件)人教新起點(diǎn)英語三年級(jí)下冊(cè)
- 財(cái)務(wù)管理專業(yè)《生產(chǎn)實(shí)習(xí)》教學(xué)大綱
- 一年級(jí)口算天天練(可直接打印)
評(píng)論
0/150
提交評(píng)論