NATIONALSTANDARD

OFTHEPEOPLESREPUBLICOFCHINA

CodeforConstructionandAcceptanceof

GroundingConnectionElectricEquipment

InstallationEngineering

GB50169-2016

ChiefDevelopmentDepartment:ChinaElectricityCouncil

ApprovalDepartment:MinistryofHousingandUrbanRuralDevelopment

-

ofthePeoplesRepublicofChina

ImplementationDate:Apr1,2017專用

人人文庫

ChinaPlanningPress

Beijing2020

ChineseeditionfirstpublishedinthePeoplesRepublicofChinain2017

EnglisheditionfirstpublishedinthePeoplesRepublicofChinain2020專用

byChinaPlanningPress

rd

3Floor,CTower,GuohongBuilding

No.A11,Muxidi-Beili,XichengDistrict

Beijing,100038

PrintedinChinabyBeijingJingyintangGraphicPrintingCenter

?2017byChinaElectricityCouncil

Allrightsreserved.Nopartofthispublicationmaybereproducedortransmittedinanyformor

byanymeans人人文庫,graphic,electronic,ormechanical,includingphotocopying,recording,

oranyinformationstorageandretrievalsystems,withoutwrittenpermissionofthepublisher.

Thisbookissoldsubjecttotheconditionthatitshallnot,bywayoftradeorotherwise,belent,

resold,hiredoutorotherwisecirculatedwithoutthepublisherspriorconsentinanyformof

blindingorcoverotherthanthatinwhichthisispublishedandwithoutasimilarcondition

includingthisconditionbeingimposedonthesubsequentpurchaser.

ISBN978-7-5182-1139-5

AnnouncementoftheMinistryofHousingandUrban-Rural

DevelopmentofthePeoplesRepublicofChina

No.1260

AnnouncementoftheMinistryofHousingandUrbanRuralDevelopmenton

-

PublishingtheNationalStandardofCodeforConstructionandAcceptanceof

GroundingConnectionElectricEquipmentInstallationEngineering

TheCodeforConstructionandAcceptanceofGroundingConnectionElectricEquipment

InstallationEngineeringhasbeenapprovedasanationalstandardwithaserialnumberofGB50169-

2016,andshallbeimplementedfromApril1,2017.Inthisstandard,clauses3.0.4,4.1.8,4.2.9are

mandatoryonesandmustbeimpletmentedstrictly.TheoriginalnationalstandardCodefor

ConstructionandAcceptanceofGroundingConnectionElectricEquipment專用InstallationEngineering

GB50169-2006isabolishedatthesametime.

AuthorizedbytheResearchInstituteofStandardsandNorms,MinistryofhousingandUrban

-

RuralDevelopmentofP.R.China,thisStandardispublishedanddistributedbyChinaPlanningPress.

MinistryofHousingandUrbanRuralDevelopmentofthePeoplesRepublicofChina

-

August18,2016

人人文庫

中華人民共和國住房和城鄉(xiāng)建設(shè)部公告

2019年第338號

住房和城鄉(xiāng)建設(shè)部關(guān)于發(fā)布《電氣裝置安裝工程

接地裝置施工及驗(yàn)收規(guī)范》

等10項(xiàng)工程建設(shè)標(biāo)準(zhǔn)英文版的公告

現(xiàn)批準(zhǔn)《電氣裝置安裝工程接地裝置施工及驗(yàn)收規(guī)范》(GB50169—2016)、《±800kV

直流換流站設(shè)計(jì)規(guī)范》(GB/T50789—2012)、《1000kV系統(tǒng)電氣裝置安裝工程電氣設(shè)備交

接試驗(yàn)標(biāo)準(zhǔn)》(GB/T50832—2013)、《光伏發(fā)電站施工規(guī)范》(GB/T專用50794—2012)、《光伏發(fā)

電站設(shè)計(jì)規(guī)范》(GB/T50797—2012)、《光伏發(fā)電工程驗(yàn)收規(guī)范》(GB/T50796—2012)、《電

氣裝置安裝工程電氣設(shè)備交接試驗(yàn)標(biāo)準(zhǔn)》(GB50150—2016)、《電力設(shè)施抗震設(shè)計(jì)規(guī)范》

(GB50260—2013)、《110kV~750kV架空輸電線路施工及驗(yàn)收規(guī)范》(GB50233—2014)、《電

氣裝置安裝工程串聯(lián)電容器補(bǔ)償裝置施工及驗(yàn)收規(guī)范》(GB51049—2014)英文版。工程建

設(shè)標(biāo)準(zhǔn)英文版與中文版出現(xiàn)異議時(shí),以中文版為準(zhǔn)。

工程建設(shè)標(biāo)準(zhǔn)英文版由住房和城鄉(xiāng)建設(shè)部組織中國計(jì)劃出版社出版發(fā)行。

中華人民共和國住房和城鄉(xiāng)建設(shè)部

2019年12月11日

人人文庫

Foreword

ThiscodeisrevisedbyChinaElectricPowerResearchInstituteandrelevantdepartmentsonthe

basisofGB50169-2006ElectricalEquipmentInstallationEngineeringCodeforConstructionand

AcceptanceofGroundingDevicesaccordingtotherequirementsoftheAnnouncementofPrintingand

DistributionofEstablishmentandRevisionPlansforNationalStandardsinEngineeringConstruction

2013(JIANBIAO〔2013〕No.6)issuedbyMinistryofHousingandUrbanRuralDevelopment.

-

Thiscodecomprises5chapterswiththemaincontentsasfollows:General;Terms;Basic

Requirements;Groundingofelectricequipment;Engineeringhandoverandacceptance.

Comparedwiththeoriginalcode,thiscodeaddsthefollowingcontents:1.BasicRequirements;

2.Resistancereductionofgroundingconnection;3.GroundingofWTGSsandphotovoltaicpower

station;4.Groundingofrelayingprotectionandautomaticsafetyequipment;5.Groundingagainst

lightninginductionandstaticelectricity.

Theprovisionsprintedinboldtypeinthiscodearemandatoryonesandmustbeimpletmented

strictly.

TheMinistryofHousingandUrbanRuralDevelopmentofthePeople專用sRepublicofChinaisin

-

chargeoftheadministrationofthiscodeandtheexplanationofthemandatoryprovisions.China

ElectricityCouncilisresponsiblefortheroutinemanagement.ChinaElectricPowerResearchInstitute

isresponsiblefortheexplanationofspecifictechnicalcontents.

Allrelevantorganizationsarekindlyrequestedtosumupandaccumulateyourexperienceinactual

practicesduringtheprocessofimplementingthiscode.Therelevantopinionsandadvice,whenever

necessary,canbepostedorpassedontoChinaElectricPowerResearchInstitute(Address:No.33,

SouthBinheRoad,XichengDistrict,BeijingCity,Postalcode:100055)forreferenceinfuturerevision.

ThefollowingaretheChiefDevelopmentOrganization,ParticipatingDevelopmentOrganizations,

ChiefDraftingStaffandChiefReviewStaffofthiscoderespectively:

ChiefDevelopmentOrganization:

ChinaElectricPowerResearchInstitute

ParticipatingDevelopmentOrganizations:

StateGridSmartPowerGridResearchInstitute

人人文庫ChinaSouthernPowerGridGuangdongProvinceTransmissionandTransformation

EngineeringCompany

StateGridShaanxiElectricPowerCompanyElectricPowerResearchInstitute

AnhuiElectricPowerConstructionEngineeringQualitySupervisionCenterStation

GezhoubaGroupsElectricPowerCompanyLtd.

CEECTianjinElectricPowerConstructionCo.,Ltd.

BeijingShuangyuanEngineeringConsultingandSupervisionCo.,Ltd.

NorthChinaPowerDesignInstituteEngineeringCo.,Ltd.

BeijingAlldayScienceandTechnologyCo.,Ltd.

JiangsuJinheyiCompositeNewMaterialCo.,Ltd.

1··

ChiefDrafters:

ChenXinHanYuJingJinHeGuanhengChenChangcaiWangSen

LiuShihuaGeZhanyuZhouWeixinXuChunliMaGuangWangWei

SunYongchunZhuZhixiang

ChiefReviewers:

ChenFayuXuJunDuShuchunLiQianFangJingYanGuozeng

LiaoGuanghongWeiGuozhuWangYumingLongQingzhiWangGuomin

ChengYuntangGuWei

ChiefTranslators:

JingJinTianXiaoChenXinHanYuMaGuangHaoWenkui

ChengYangchunXuJunGeZhanyuZengGuangyuGuWeiLiKaizhou

ZhuHongHeFei

專用

人人文庫

2··

Contents

1GeneralProvisions……………(1)

2Terms…………………………(2)

3BasicRequirements……………(4)

4GroundingofElectricEquipment………………(6)

4.1SelectionofGroundingConnection………………(6)

4.2LayingofGroundingConnection…………………(8)

4.3ConnectionofGroundingConductorandGroundingElectrode………(10)

4.4ResistanceReductionofGroundingConnection……………………(12)

4.5GroundingofWindTurbineGeneratorSystem(WTGS)andPhotovoltaicPowerStation………………(13)

4.6GroundingofAirterminationSystem……………(14)

-

4.7GroundingofTransmissionTowers………………(15)

4.8GroundingofMainControlBuilding,DispatchingBuildingandCommunicationStation……(16)

4.9GroundingofRelayProtectionandAutomaticSafetyEquipment……(17)

4.10GroundingofMetalSheathofPowerCable………(19)

4.11GroundingofDistributionElectricEquipment……………………專用(19)

4.12GroundingofElectricEquipmentinBuildings……………………(20)

4.13GroundingofPortableandMobileElectricEquipment………………(21)

4.14GroundingagainstLightningInductionandStaticElectricity…………(21)

5EngineeringHandoverandAcceptance………(23)

-

ExplanationofWordinginThisCode……………(24)

ListofQuotedStandards…………(25)

人人文庫

1GeneralProvisions

Thiscodeisformulatedtoensurethequalityoftheelectricequipmentinstallationengineering

1.0.1

aboutgroundingconnection,facilitatetheimprovementofengineeringconstructiontechnologyand

guaranteethesafeoperationofgroundingconnection.

Thiscodeisapplicabletotheconstructionandacceptanceofgroundingconnectionoftheelectric

1.0.2

equipmentininstallationengineeringbutnottotheconstructionandacceptanceoftheDChighvoltage

-

transmissiongroundingelectrode.

Constructionandacceptanceofgroundingconnectionshallnotonlymeettherequirements

1.0.3

stipulatedinthiscode(standard),butalsothoseinthecurrentrelevantonesofthenation.

專用

人人文庫

·1·

2Terms

Groundingelectrode

2.0.1

Itmeansthemetalconductorsburiedintheground,whichdirectlycontactstheearth.Itincludes

horizontalandverticalgroundingelectrodes.

Naturalgroundingelectrode

2.0.2

Naturalgroundingelectrodereferstothosedirectlycontacttheearthandcanbeservedas

grounding,suchasmetalstructures,metalwellpipes,foundationsofRCCbuilding,metalpipelineand

equipment,etc.

Airterminationsystem

2.0.3-

Itisthegeneraltermofdevicesreceivinglightningstrike,includinglightningrod,lightningstrip,

lightningline,lightninggrid,metalroofandmetalstructure.

Groundingconductor

2.0.4

Itmeansthemetalconductorthatconnectsgroundterminalsofelectricequipmentorair

-

terminationsystemwithgroundingelectrode.Ithasnocurrentloadundernormalcircumstances.

Groundingconnection專用

2.0.5

Itisthegeneraltermofgroundingelectrodeandgroundingline.

Grounding

2.0.6

Itmeanstheconnectionofgroundingelectrodewiththeelectricequipment,facilitiesandover

-

voltageprotectiondevicesofthepowersystemorbuildingsthroughgroundingline.

Groundingimpedance

2.0.7

Itreferstotheimpedancebetweenthesetpointandthereferencepointofthesystem,deviceor

equipmentatagivenfrequency.

Groundresistance

2.0.8

Itmeanstherealpartofgroundingimpedance.Groundresistancevalueunderthepowerfrequency

isthepowerfrequencygroundresistance.

Neutralline

2.0.9

Itreferstotheconductorelectricallyconnectswithneutralpointandcanbeusedforpower

distribution.

Protectiveground

2.0.10人人文庫

Itreferstogroundingsetformetalshellofelectricequipment,theframeworkofpowerdistribution

equipmentandpolesandtowersoftransmissionlinestopreventthepersonnelandequipmentfrom

possibleelectrificationduetoinsulationdamage.

Concentratedgroundingconnection

2.0.11

Concentratedgroundingconnectionistheadditionalgroundingconnectiontoenhancediffusingof

lightningcurrentandreducethepotential.Forexample,theverticalgroundingelectrodeisequipped

nearthelightningrod.

Groundinggrid

2.0.12

Itreferstothenettedgroundingdevice,whichiscomprisedofverticalandhorizontalgrounding

·2·

electrodesandhasthefunctionsofcurrentdischargeandvoltagesharing.

-

Exothermicwelding

2.0.13

Itisaweldingmethodinwhichworkpieceisheatedandmoltendirectlyorindirectlythroughthe

chemicalreactionbetweenmetaloxideandaluminumpowder.

Equipotentialgroundinggrid

2.0.14

Itreferstothegridwhichcomprisesofhorizontalconductorsandinwhicheachnodeis

equipotential.Itisfinallyconnectedwiththegroundinggridinthesoil.

專用

人人文庫

·3·

3BasicRequirements

Thegroundingconnectionshallbeinstalledbytheconstructioncompanyaccordingtothe

3.0.1

approveddesigndocuments.Specialpersonnelfromprojectmanagementcompanyandsupervision

companyshallberesponsibleforsupervision.

Thenewtechnology,newprocessandnewmaterialsshallbetestedandsubjecttonational

3.0.2

qualifiedverificationandvalidationtomeettherequirementofdesignandsafeuse.

Theinstallationofgroundingconnectionshallbeincoordinationwithcivilworks.Theconcealed

3.0.3

partshallbechecked,acceptedandrecordedbyrelevantdepartmentsbeforebeingcoveredup.

3.0.4Thefollowingmetalpartsintheelectricequipmentmustbegrounded:

1Metalbase,frame,shell,drivingdeviceofelectricequipment;

2Metalbaseandshellofportableormobileelectricapparatus;

3Metalboxofcubiclesubstation;

4SecondarywindingsofCTandPT;

5Metalframeandbaseofpanel(cabinet,box)fordistribution,controlandrelayprotection

;專用

andconsole

6Metalsheath,jointbox,terminalsandmetalprotectiontubeofpowercablesaswellas

shieldinglayerofsecondarycable;

7Cabletray,bracketandsupportstructureofcablewell;

8Framesandequipmentsupportsinsubstation(converterstation);

9Powerlinetowersequippedwithoverheadgroundwireorelectricequipment;

10Metalfencingofpowerdistributionunit;

11Metalshellofelectricalheatingequipment.

DCsystemneedstobegroundedshallbeinaccordancewiththefollowingrequirements

3.0.5

Thegroundingconductorthatcanformloopcircuitwiththegroundandthroughwhichthe

1

currentnormallyflowsshallbelaidalongtheinsulatingpaddingplateandshallnotbeconnectedwith

metalpipes,buildingsorequipmentcomponentsthroughmetal;

Thegroundingconnectionshouldnotbelaidinsoilwherethecorrosivesubstancecanbe

2

producedbyelectrolyzing.Theexternalgroundingconnectionorsoilimprovementmaybeadoptedif

necessary;人人文庫

TheDCpositivegroundingconductorandgroundingelectrodeshallnotbeconnectedwith

3

naturalgroundingelectrodethroughmetal;thedistancebetweenthemshallnotbelessthan1mwhen

thereisnoinsulation.

Theelectricequipmentshallbereliablyconnectedwiththegroundinggrid.Intheexpansion

3.0.6

project,theconnectionofgroundinggridwiththeexistingoneshallmeetthedesignrequirementsand

shallbeatleastattwopoints.

Thegroundingconnectionacceptancetests,includingconductiontest,shallbecarriedoutafter

3.0.7

thegroundingconnectionisconstructedassoonaspossible.Thegroundresistancevalueshallmeetthe

requirementsofdesign.

·4·

Thegroundingconnectionintheregionwithhighsoilresistivitymaybeputintooperationafter

3.0.8

thecorrespondingmeasuresaredeterminedbythedesigndepartmentifthegroundresistancecannot

meettherequirements.

Thefollowingmetalpartsattachedtothegroundedelectricequipmentandproductionfacilities

3.0.9

maynotbegrounded:

Shellsoftheelectricalmeasuringinstrument,relayandotherlowvoltageapparatusesinstalled

1-

inthedistributionboard,controlpanelandpowerdistributionunits;

Shellsofmotorandelectricapplianceinreliableelectriccontactwiththemachinetoolandbase;

2

Metalsupportinbatteryroomwiththeratedvoltageof220Vandbelow.

3

Groundingconductorshallnotbeusedforotherpurposes.

3.0.10

專用

人人文庫

·5·

4GroundingofElectricEquipment

4.1SelectionofGroundingConnection

Thegroundingconnectionsshallutilizenaturalgroundingelectrodeburieddirectlyunderground

4.1.1

orunderwater.Thefollowingnaturalgroundingelectrodemaybeused:

Metalpipesburiedunderground,excludingpipesconveyingcombustibleorexplosivematerials;

1

Metalwellpipes;

2

Metalstructureofbuildingreliablyconnectedwiththeground;

3

Metalpipes,pilesandfoundationreinforcingmeshofthehydraulicstructuresandothersimilar

4

structures.

GroundingconductorofACelectricequipmentmaybegroundedthroughthefollowing

4.1.2

groundingelectrodes:

Metalstructure,beamandcolumnofbuildings;

1

Metalstructuresinproduction,suchascranetrack,passageway,platform,frameofcraneand

2

elevator,steelbeamforconveybelt,frameofelectrostaticdustcollectorandsoon.

Thegroundingconnectioninthepowerplantandsubstationshall專用besetwithnotonlynatural

4.1.3

groundingelectrodebutalsoartificialgroundingelectrode,i.e.thegroundinggriddominatedby

horizontalgroundingelectrode.Themeasuringwellseparatingnaturalgroundingelectrodefrom

artificialgroundingelectrodeshallbefurnished.Substationanddistributionsubstationof3kV~10kV

maynotbeartificiallygroundedwhenthereinforcingmeshinthebuildingfoundationisusedasthe

groundingelectrodeandthegroundresistancesatisfiesdefinedvalue.

Selectionofthegroundingconnectionmaterialshallbeinaccordancewiththefollowing

4.1.4

requirements:

Exceptthetemporarygroundingconnection,thegroundingconnectionshallbehotdip

1-

galvanizedifsteelisused.Thehotdipgalvanizedroundsteelandflatsteelshallbeusedforhorizontal

-

laying.Thehotdipgalvanizedanglesteel,steeltubeorroundsteelshallbeusedforverticallaying;

-

Whenflatcopperstrip,copperstrandedwire,copperrod,coppercoatedsteel(roundwireand

2

strandedwire),zinccoatedsteelandothermaterialsareusedasthegroundingconnection,theselection

shallmeettherequirementsofdesign;

Aluminumconductorsshallnotbeusedasthegroundingelectrodeorgroundingconductor.

3人人文庫

Thecrosssectionareaoftheartificialgroundingelectrodeofthegroundingconnectionshall

4.1.5

meettherequirementsonthermalstability,voltagesharing,mechanicalstrengthandcorrosion

-

resistance.Thecrosssectionareaofthehorizontalgroundingelectrodeshallnotbelessthan75%of

thatofthegroundingconductorconnectedtotheabovementionedgroundingconnection,andshallnot

belessthanthespecificationlistedinTable4.1.51andTable4.1.52.Thecrosssectionareaofthe

--

outgoinglineofthegroundingelectrodeofthepowerlinetowershallnotbelessthan50mm2.

·6·

Table4.1.5-1Minimumspecificationofsteelgroundingelectrodeandgroundingconductor

Type,specificationandunitAbovegroundUnderground

Diameterofroundsteel(mm)88/10

FlatCrosssectionarea(mm2)4848

steelThickness(mm)44

Thicknessofanglesteel(mm)2.54

Wallthicknessofsteelpipe(mm)2.53.5/2.5

Notes:1Thenumeratoranddenominatorofthediameteroftheundergroundroundsteelcorrespondtotheoverheadlineandthe

groundinggridofthepowerplantandsubstationrespectively.

2Thenumeratoranddenominatorofthewallthicknessoftheundergroundsteeltubecorrespondtothegroundembeddedinthe

soilandembeddedinindoorconcreterespectively.

Table4.1.5-2Minimumspecificationofcopperandcoppercoatedsteelgroundingelectrode

Type,specificationandunitAbovegroundUnderground

Horizontalgroundingelectrode8

Diameterofcopperrod(mm)8

Verticalgroundingelectrode15

Crosssectionarea(mm2)/thickness(mm)ofcopperbar50/250/2

Wallthicknessofcopperpipe(mm)23

Crosssectionareaofcopperstrandedconductor(mm2)5050

Diameterofcoppercoatedroundsteel(mm)8專用10

Diameterofcoppercoatedsteelstrandedconductor(mm)810

Crosssectionareaofcoppercoatedflatsteel(mm2)/thickness(mm)48/448/4

Notes:1Thebarecopperstrandedwireshouldnotbeusedasthegroundingelectrodeofsmallgroundingconnection.Whenitisusedas

thegroundingelectrodeofthegroundinggrid,thecrosssectionareashallmeettherequirementsofdesign.

2Thesinglestranddiameterofthecopperstrandedconductorisnotlessthan1.7mm.

3Thecoppercoatedsteelspecificationisthesteelsizeandthecopperlayerthicknessshallnotbelessthan0.25mm.

Thezinclayerthicknessofthehotdipgalvanizedsteelandzinccoatedsteelforconnecting

4.1.6-

electrodeshallmeettherequirementsofdesign.

Theminimumcrosssectionareaoftheexposedgroundingconnectorabovegroundconnectedto

4.1.7

thegroundingelectrodeorprotectiveconductor(PE)onthelowvoltageelectricequipmentshallmeet

-

therequirementsoftheprovisionsinTable4.1.7.

Table4.1.7Minimumcrosssectionareaofexposedcoppergroundingconductor

onlow-voltageelectricequipmentground

Minimumcrosssectionarea

Name

人人文庫(mm2)

Exposedlaidbareconductor4

Insulatedconductor1.5

Groundingcoreofcableorgroundingcoreofmulticoreconductorwrappedinsidethe

-1

sameprotectiveshellwithphasewire

4.1.8Theflexiblemetaltubing,metalsheathormetalnetofpipelineinsulationlayer,the

conductorleadsheetoflow-voltagelightingnetworkandthemetalsheathofcablemustnotbe

usedasgroundingconductors.

Theselffixedconnectororthehoseconnectorshallbeadoptedatbothendsoftheflexiblemetal

4.1.9-

tubingandtheflexiblemetaltubingshallbeelectricallywellconnectedwiththesteelpipese

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

評論

0/150

提交評論