版權(quán)說(shuō)明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡(jiǎn)介
DNV
WHENTRUSTMATTERS
WINDSPEEDANDREAR
GLASSBREAKAGEON
BIFACIALPVMODULES
MOUNTEDONTRACKERS
Correlationbetweenmid-levelwindspeedandrearglassbreakagesonnon-largeformatbifacialPVmodulesontrackersinasolarfarm
Authors:
DarrylWang
AndiHermawanEvanWoolard
WHITEPAPER
WindspeedandrearglassbreakageonbifacialPVmodulesmountedontrackers
CONTENTS
Abstract3
1.Introduction4
2.PVsystemsdesign5
3.Method5
4.Resultsanddiscussions6
5.Summary9
Acknowledgement9
References9
-2-
WindspeedandrearglassbreakageonbifacialPVmodulesmountedontrackers
ABSTRACT
Totheauthors’knowledge,thisisthefirstreportwithonsite-recordedevidencessuggestingthat
not-highbutmid-levelwindspeedisamajorinfluenceonoratriggerforlarge-scale(>15%)rearglassbreakagesonbifacialPVmodulesmountedontrackersinasolarfarmlocatedintheAsiaPacificregion.
Timeandspatialcorrelationswerefoundbetweenmid-levelwindspeedrecordsandrearglassbreakagesonnon-largeformatglass/glassbifacialPVmodulesmountedonsingle
portrait(1P)single-axistrackers.Fortimecorrelation,
intra-daymid-levelwindspeedclusterswerefoundto
consistentlyprecedemajoronsiteO&Meventsthatincludes
orcanberelatedtoglassbreakages.Goodspatialcorrelationwasalsoobserved,wheretheareaswithhighestglass
breakageconcentrationswerefoundclosetoaweather
stationthataccountsfor~75%ofallthemid-levelwindspeedrecords.Themaximumwindspeedis,however,wellbelow
thresholdsthatcanexertwindloadexceedingthetypical
moduledesignwindload,representinganengineering
missinglinkthatisconsistentwithotherworks.Theglass
crackpatternsfoundonsitearealsodiscussed.ItishopedthisworkcanhelpthePVR&Dcommunitytosharpenthefocus
towardsfindingthemissinglink.
-3-
WindspeedandrearglassbreakageonbifacialPVmodulesmountedontrackers
-4-
1.INTRODUCTION
GlassbreakageinbifacialPVmodulesinstalledinsingle-axistrackers-basedsolarfarmshasbeen
increasinglyreportedinrecentyears[1]-[6].Whileearlyattentionontrackermodulefailureswason
2Ptrackersduetotorsionalgalloping[1],since2020thereisagrowingbodyofreportsforrearglass
breakagesafflictingsolarfarmsinstalledwith1Ptrackerdesignsandlargeformat(≥2.5m2[4])bifacialglass/glassmodulessupportedonitslongedgesbyshortmounts[2]-[4](Figure1showsanexample).
Importantly,suchbreakagesoccurintheabsenceofhigh
windspeed(let'scallthis"thresholdwindspeed")eventsthatcouldexplainthemodulebreakagebasedonthemodule
manufacturer'sdesignwindloadonapprovedmodule
mountingdesignwithshort(usually~400mm)mountsonsuchtrackerdesigns[2]-[6].Thisrepresentsanexistingengineeringknowledgegapofanominousfailuremodethat,giventhattrackersystemsarealreadyamainstreamPVdesign[2],couldhavewideimplicationsintheglobalsolardecarbonizationdriveifleftunresolved.Whilemanyhypotheticalexplanationswereoffered[2]-[6],therehasbeenlittleclearevidencetofurthersteertheattention
towardsanyofthehypotheses.
Inthiswork,wereportanencounterwith>15%ofbifacialPVmodulessmallerthanlargemoduleformatson1Ptrackersafflictedwithrearglassbreakagesacrossthesolarfarm.
Moreover,mid-levelwindspeedlevelswerealsofoundto
correlatewellwithglassbreakagesbothspatiallywithinthesolarfarmandchronologicallywhencomparedtomajor
infieldO&Mevents(includeglassbreakages),whichsuggestthatglassbreakageswereinfluencedbymid-levelwind
speedeventsthatarewellunderthethresholdwindspeeds.Thisisthefirstreportwithsuchcorrelationbetweenonsiterecords.
Allfiguresinthispublicationarerepresentativeillustrationsoftheactualencounter,andsomedetailsareintentionallykeptambiguouswithwideranges,buttheoverallpresentation
herecanstillconveyasimilarstoryoftheactualencounter.
FIGURE1
Atypical1Psingle-axistrackerdesignwithframedbifacialdouble-glass144half-cut-cellsPVmodules.Imageistakenfrom[7].
WindspeedandrearglassbreakageonbifacialPVmodulesmountedontrackers
-5-
2.PVSYSTEMSDESIGN
MODULE
Reputablebrand,
144half-cutc-Sicells
bifacial,2mmglassfront
andback,3junctionboxes,
30-35mmframes.
SOLARFARM
10-50MWp,2-7yearsold,locatedinAPAC.
Thesolarfarmdetailsareasfollows:
MODULEAREA
MOUNTINGSTRUCTURE
Between2.0-2.3m2
IPsingle-axistracker,
shortmountattached
tothemid-sectionof
modulelong-sideframes.
Sitelayoutisapproximatelyrectangular,withtwometeorologicalstationseachcontainingananemometer(windspeedsensor;~3mhigh)recordingperminutewindspeeddatasinceCOD.
3.METHOD
Twodocuments,compiledbythesolarfarmownerandrecordedontwo
differentdates,countingmoduleswithglasscracksandtheirlocationsin
thesolarfarmwerereviewed.ThelatestdocumentisdatedwithinQ2-Q32023,whiletheearlierdocumentisdatedwithin12monthsoftheformer.MonthlyO&MrecordswerereviewedsincetheplantCOD.Meteorologicaldata,includingwindspeedatperminutebasis,fromthetwoweather
stationsinthesolarfarmwerealsoreviewed.Acomprehensiveassessmentwasconductedacrossthevariousdata.Asitevisitwasalsodonetoassessthemoduleswithglasscracks.Assessmentswerealsodoneonmodule
productionbatchesandglasssuppliers/batchesbutnoclearcorrelationtotheglassbreakageswereuncovered.Thesubsequentfocusisoncrackpatternsandwindspeeddata.
WindspeedandrearglassbreakageonbifacialPVmodulesmountedontrackers
-6-
4.RESULTSANDDISCUSSIONS
A.Crackpatterns
Fromonsiteinspections,glasscrackswereonlyfoundon
therearglassofthebifacialmodules.Thecrackpatternsaresimilarthoseinheat-strengthenedglassesshowninFigure2part(b).Thisisconsistentwiththeheat-strengthenedglassesusedinthemodulesasshowninthemoduledatasheet.
AnnealedHeat-strengthenedFullytempered
FIGURE2
Crackpatternsforannealed,heat-strengthenedandfullytemperedglasses[8]
FIGURE3
Typicalcrackpatternsfoundintherearglassesofthecrackedmodules.
Theredlinesarecrackpatternsthatmostlyruninthedirectionofthelong
sideframe,whiletheorangelinesarecrackpatternsthatrunsclosetothe
short-sideframes,withsomeeventuallyturntowardsthecenterofthemodule.
FRONTGLASS
ENCAPSULANT
2
3
REARGLASS
1
4
FIGURE4
Compressive(yellowarrows)andtensilestresses(redarrows)exertedoneachlayerofthelaminateinalaminatebow.Attheglass/encapsulantinterfaces
(3&4),thereareinterfacialcounter-forces,whilethecompressiveandtensilestressesattheair-sidesurfaces(1&2)arefree-standing.
Mostoftherearglasscrackswerealsofoundtoruninthe
directionparalleltothemodulelong-sideandendinginto
oneofthe3junctionboxes(Figure3).Thelong-sidecrack
routeandrearglasscracksisconsistentwithanonsite
observationthatmostofthemoduleshavemildbutvisuallyapparentdownwardbowinginthecenteralongthedirectionoftheshortside(notethattrackermountsareonmid-
sectionsofthelongsidemoduleframes).ThesecrackroutesinFigure3areconsistentwiththepresenceofdrillholesintherearglassatthe3junctionboxlocationsthatcanactasstressconcentratorspots,thepropensityfortherearglass
(vsfrontglass)thatisundertensilestresstobreakfirstwhenthemodulelaminateisinthedownwardbowingstate
(Figure4),andtheexpectationthatglasscrackswouldpropagateinthemodulelongsidedirectionwhenthebowingisalongitsshortside(Figure4).
Whilethecrackpatternscanbeexplainedbymodulebowanddrillholesinnon-temperedglass,itisnotconclusivethattheseareenoughtoactasthetriggersoftheglass
breakages.
WindspeedandrearglassbreakageonbifacialPVmodulesmountedontrackers
-7-
B.WindspeedrecordsvsO&Mrecords
1
2
FIGURE5
Arepresentativerectangularsketchofthesolarfarmareawitha
representativespatialheatmap(inblue)ofcrackedmodulesacrossthesite.Theyellowsquaresrepresentthetwoonsitemeteorologicalstations1and2(let’scallthem‘ST1’and‘ST2’).
Shareofwindspeedrecords>10m/s
80%
70%
60%
50%
40%
30%
20%
10%
0%
ST1ST2
FIGURE6
Shareofwindspeedrecordcumulativecountsexceeding10m/sinthetwometeorologiclstationsinFigure5sinceCOD.
Fromdesktopanalysisofthelatest(inQ2-Q32023)modulecrackcount,thebreakagecountis>15%ofallmodules.
Figure5showsthesolarfarmsitewithaspatialheatmapofthebreakagesandlocationoftwometeorologicalstations
(ST1)and(ST2),eachwithananemometer.Thisheatmap
showsthatwhiletheglassbreakageisdistributedoverthe
site,thereareselectedareaswithhigherconcentration
(especiallyrightside).Theearliermodulecrackcounthas
10-15%breakagerateandshowsaspatialdistributionsimilarasFigure5butislessdense.
Fromtheper-minutewindspeedrecordssinceCOD,a
cumulativecountofmid-levelwindspeedlevels(>10m/s)(Figures6and7)showsthat(1)themid-levelwindspeed
countismuchlessthan0.01%oftotal,whichappearsto
showmid-levelwindspeedsarenotcommonon-site,(2)
ST2accountsfor~3xmorecountsthanST1(Figure6)whichappearstocorrelatewellspatiallywiththeglassbreakageheatmapinFigure5.
Itisalsonotedthatthemaximumwindspeedisunder
15m/s(Figure7).Basedoninternalcalculations,itis
~2.5xlowerthanthethresholdwindspeedneededtoexert
1600Padesignwindloadonthemodule/trackershortmountdesign,basedonthemodulemanufacturer’sinstallation
manual.Thisisconsistentwithfindingselsewhereofbifacialmodulecrackingintheabsenceofnotablewindspeed
events[2]-[6].
Figure7showsatimeplotofthemid-levelwindspeed
recordssinceCOD,whichrevealsthatmid-levelwindeventsoccuronveryfewdays,withmid-levelwindcluster(≥3countsaday)daysoccurringonlyonafewselectdays(veryrare).
Interestingly,fromthemonthlyO&Mrecordsandother
documentations,wefoundfourO&Mactivities(yellow
overlaysinFigure7),eitherdirectlyorlikelyrelatedtomoduleglassbreakages,thatappearstobeconsistentlyprecededbytherarelyoccurringaforementionedmid-levelwindcluster
days(seenumbersatoptheyellowoverlaysinFigure7).
1.Modulerearglasscracks,followedbyrepeatedinspections(overmultipleconsecutivemonths)
2.Insulationresistance(Riso*)issuesfrominverters
3.Moduleglassbreakagecountsdocumentation(earlier)
4.Moduleglassbreakagecountsdocumentation(latest)
*RisoissuesininverterscanbecausedbymorningdewselectricallyconnectingtheinternalPVmodulecircuitrytogroundthroughglasscracks.
2
1
4
3
Windspeed[m/s]
1413.5 1312.5 1211.5 1110.5 109.59
ST1ST2Days[A.U.]
FIGURE7
Mid-levelwindspeed(>10m/s)recordsmeasuredintheonsitemeteorologicalstations1(ST1)and2(ST2)fromFigure5;theyellowboxoverlaysshowwhenandhowlongarethefourmajorO&Mevents.Thex-axisfullrangecanbeupto7years.
WindspeedandrearglassbreakageonbifacialPVmodulesmountedontrackers
-8-
Alltheabovewindspeedandglasscrackobservations
showthatthemoduleglassbreakagescorrelatewellboth
spatiallyandtemporallywithmid-levelwindspeedevents,
andsuggestthatthesemid-levelwindspeedeventseither
haveamajorinfluenceoristhetriggerforthemodule
glassbreakages.Moreover,withthemaximumwindspeed
recordedbeingmuchlowerthanthethresholdwindspeedneededtoexceedthemoduledesignwindload,theexistingwind-loadengineeringdesignunderstandingof1Psingle-
axistrackers(includingwithshortmounts)maybeinsufficienttomitigateagainstinfieldmodulefailuresmodes[2]-[6],
whichrepresentsamissinglink.Thisreportalsoshows
bifacialglassbreakagescanalsohappentonon-large-formatmodules.
Severalhypotheseshavebeenraisedinpreviousworks
[2]-[6]toexplainforthisunexpectedfailureintheabsenceofhighwindspeeds.Increasedmodulesizeswithshorter
trackersupportbeamshavemadethemoduleglassesevolvefromaloadsupportedbythetrackerstoaloadbearing
componentinstead[2]-[4],makingexistingtestingregimesnolongersuitabletotestforinfieldfailuremodes.
Thefailurecouldalsobeduetoasymmetricwind-loads
inmodules-on-trackersystemspresentinfield[4]-[6],
ormultiplestresseshappeningallatonceduringinfield
operations[9],somethingwhichstaticloading(SML)testsonPVmoduleswouldnothavesufficientlycovered.Therearealsoreportsofdynamicmechanicalload(DML)tests
replicatingtheglassbreakagepatternsobservedinfield
[4]thatweremissedbySMLtests.Itishopedthisreport
canhelpthePVR&Dcommunitytofurthersteerthefocustowardsfindingthemissinglinkintheexistingengineeringunderstandingofthismatter.
WindspeedandrearglassbreakageonbifacialPVmodulesmountedontrackers
-9-
5.SUMMARY
Wereport,forthefirsttime,evidencessuggestingthat
not-highbutmid-levelwindspeedisamajorinfluenceon
oratriggerforlarge-scale(>15%)rearglassbreakageson
bifacialPVmodulesontrackersinasolarfarmlocatedintheAPACregion.Timeandspatialcorrelationsinthesolarfarmwerefoundbetweenmid-levelwindspeedrecordsandrearglassbreakagesonnon-large-formatglass/glassbifacialPV
modulesmountedonsingleportrait(1P)single-axistrackers.Themaximumwindspeedis,however,wellbelowthresholdsthatcanexertwindloadexceedingthetypicalmoduledesignwindload,representinganengineeringmissinglinkthatwerealsoreportedinotherworks.Theglasscrackpatternsfoundonsitearealsodiscussedanditscausesareexcludedasthetrigger.ItishopedthisworkcanhelpthePVR&Dcommunitytosharpenthefocustowardsfindingthemissinglink.
ACKNOWLEDGEMENT
TheauthorswouldliketoacknowledgeMichaelNiu,RachelOh,andLowZhengHuaforvaluabletechnicaldiscussions,site
inspectionandoverallprojectcontributions.
REFERENCES
[1]D.Valentín,C.Valero,M.Egusquiza,A.Presas,Failureinvestigationofasolartrackerduetowind-inducedtorsionalgalloping,EngineeringFailureAnalysis,135,106137,2022
[2]T.Weber,“Glassbreakage–agrowingphenomenoninlarge-scalePV”,inPVMagazineWebinar,20November2023
[3]C.Sillerud,“CurrentissuesinPVmodulereliabilitytesting”,in50thIEEEPhotovoltaicSpecialistConference,2023,Plenary.
[4]H.Hieslmair,“Stressconcentrators”,DNV,2023,
/article/stress-concentrators-246984
[5]D.Chang,“Modulewindloadresistance:Standardsvs.reality”,inPVMagazineWebinar,30August2021
[6]S.vanPelt,“Modulewindloadresistance:Standardsvs.reality”,inPVMagazineWebinar,30August2021[7]
/monoline-plus-solar-tracker/
[8]P.C.Louter,“Adhesivelybondedreinforcedgla
溫馨提示
- 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 體檢中心前臺(tái)服務(wù)工作總結(jié)
- 租賃商業(yè)用房合同三篇
- 化工行業(yè)員工安全培訓(xùn)方案實(shí)施
- 制造行業(yè)安全管理工作總結(jié)
- 2023年高考語(yǔ)文試卷(天津)(空白卷)
- 2024年美術(shù)教案集錦7篇
- 2024年電力通信設(shè)備運(yùn)檢員理論備考試題庫(kù)及答案
- 創(chuàng)意設(shè)計(jì)人才中介合同(2篇)
- 黃金卷8-【贏在中考·黃金八卷】(解析版)
- 2025新生入學(xué)貸款還款協(xié)議合同
- 親近母語(yǔ)“西游智慧數(shù)學(xué)”系列
- 春節(jié)期間安全告知書
- 國(guó)家開(kāi)放大學(xué)電大本科《古代小說(shuō)戲曲專題》2024期末試題及答案(試卷號(hào):1340)
- 高考英語(yǔ)復(fù)習(xí)備考:語(yǔ)篇銜接連貫的“七選五”教學(xué)設(shè)計(jì)
- 貴州省銅仁市2022-2023學(xué)年高二上學(xué)期1月期末質(zhì)量監(jiān)測(cè)數(shù)學(xué)試題(含答案詳解)
- 正常分娩產(chǎn)婦護(hù)理查房
- 紅色經(jīng)典影片與近現(xiàn)代中國(guó)發(fā)展答案考試
- 2018年10月自考00015英語(yǔ)二真題及答案含解析
- 降低會(huì)陰側(cè)切率的PDCA
- 《西醫(yī)外科學(xué)》教學(xué)大綱:膽道感染及膽石病
- 私宅施工方案
評(píng)論
0/150
提交評(píng)論