【BS英國標(biāo)準(zhǔn)】BS EN 61169-37-2007 Radio-frequency connectors — Part 37 Sectional specification for STWX8 R.F connectors.doc_第1頁
【BS英國標(biāo)準(zhǔn)】BS EN 61169-37-2007 Radio-frequency connectors — Part 37 Sectional specification for STWX8 R.F connectors.doc_第2頁
【BS英國標(biāo)準(zhǔn)】BS EN 61169-37-2007 Radio-frequency connectors — Part 37 Sectional specification for STWX8 R.F connectors.doc_第3頁
【BS英國標(biāo)準(zhǔn)】BS EN 61169-37-2007 Radio-frequency connectors — Part 37 Sectional specification for STWX8 R.F connectors.doc_第4頁
【BS英國標(biāo)準(zhǔn)】BS EN 61169-37-2007 Radio-frequency connectors — Part 37 Sectional specification for STWX8 R.F connectors.doc_第5頁
已閱讀5頁,還剩24頁未讀 繼續(xù)免費(fèi)閱讀

下載本文檔

版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進(jìn)行舉報(bào)或認(rèn)領(lǐng)

文檔簡介

british standardbs en61169-37:2007radio-frequency connectors part 37: sectional specification forstwx8 r.f connectorsthe european standard en 61169-37:2007 has the status of abritish standardics 33.120.30 bs en 61169-37:2007national forewordthis british standard was published by bsi. it is the uk implementation ofen 61169-37:2007. it is identical with iec 61169-37:2007.the uk participation in its preparation was entrusted by technical committee epl/46, cables, wires and waveguides, radio frequency connectors and accessories for communication and signalling, to subcommittee epl/46/2, radio frequency connectors and waveguides.a list of organizations represented on this committee can be obtained on request to its secretary.this publication does not purport to include all the necessary provisions of a contract. users are responsible for its correct application.compliance with a british standard cannot confer immunity from legal obligations.amd. no.datecommentsthis british standard was published under the authority of the standards policy and strategy committeeon 31 may 2007 bsi 2007isbn 978 0 580 50820 2amendments issued since publicationeuropean standarden 61169-37norme europenneeuropische norm april 2007 ics 33.120.30english versionradio-frequency connectors - part 37: sectional specification for stwx8 r.f connectors(iec 61169-37:2007)connecteurs pour frquences radiolectriques -partie 37: spcification intermdiaire relative aux connecteurspour frquences radiolectriques de type stwx8(cei 61169-37:2007)hochfrequenz-steckverbinder - teil 37: rahmenspezifikationen - stwx8-hochfrequenzsteckverbinder (iec 61169-37:2007)this european standard was approved by cenelec on 2007-03-01. cenelec members are bound to comply with the cen/cenelec internal regulations which stipulate the conditions for giving this european standard the status of a national standard without any alteration.up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the central secretariat or to any cenelec member.this european standard exists in three official versions (english, french, german). a version in any other language made by translation under the responsibility of a cenelec member into its own language and notified to the central secretariat has the same status as the official versions.cenelec members are the national electrotechnical committees of austria, belgium, bulgaria, cyprus, the czech republic, denmark, estonia, finland, france, germany, greece, hungary, iceland, ireland, italy, latvia, lithuania, luxembourg, malta, the netherlands, norway, poland, portugal, romania, slovakia, slovenia, spain, sweden, switzerland and the united kingdom.ceneleceuropean committee for electrotechnical standardizationcomit europen de normalisation electrotechniqueeuropisches komitee fr elektrotechnische normungcentral secretariat: rue de stassart 35, b - 1050 brussels 2007 cenelec -all rights of exploitation in any form and by any means reserved worldwide for cenelec members.ref. no. en 61169-37:2007 e 25 en 61169-37:2007forewordthe text of document 46f/44/cdv, future edition 1 of iec 61169-37, prepared by sc 46f, r.f. and microwave passive components, of iec tc 46, cables, wires, waveguides, r.f. connectors, r.f. and microwave passive components and accessories, was submitted to the iec-cenelec parallel unique acceptance procedure and was approved by cenelec as en 61169-37 on 2007-03-01.the following dates were fixed: latest date by which the en has to be implementedat national level by publication of an identicalnational standard or by endorsement(dop)2007-12-01 latest date by which the national standards conflicting with the en have to be withdrawnannex za has been added by cenelec.(dow)2010-03-01endorsement noticethe text of the international standard iec 61169-37:2007 was approved by cenelec as a europeanstandard without any modification.contents1scope . 42normative references. .43mating face and gauge information .43.1dimensions - general connectors grade 2 (figure 1) .43.2gauges for general purpose connectors - grade 2 .63.3dimensions standard test connectors grade 0 . 94quality assessment procedure. 124.1general . 124.2rating and characteristics (see clause 6 of iec 61169-1 (qc 220000) .124.3test schedule and inspection requirements - acceptance tests .154.4procedures . 185instructions for preparation of detail specifications. .185.1general . 185.2identification of the detail specification . 185.3identification of the component . 185.4performance.195.5marking, ordering information and related matters .195.6selection of tests, tests conditions and severities . 195.7blank detail specification pro-forma for type stwx 8 connectors . 19annex za (normative) normative references to international publications with theircorresponding european publications . 25figure 1 mating face of stw x8 connectors (for dimensions and notes, see table 1) .5figure 2 gauge pins for contact of socket connectors (for dimensions, see table 2) .7figure 3 gauge for outer of socket connectors (for dimensions, see table 3) . 8figure 4 female contact (for dimensions and notes, see table 4.) .9figure 5 male contact (for dimensions and notes, see table 5) . 11table 1 mating face dimensions .6table 2 gauges dimensions .7table 3 gauge dimension.s . 9table 4 female contact dimensions . 10table 5 male contact dimensions .11table 6 rating and characteristics . 13table 7 acceptance tests . 15table 8 periodic tests . 16radio-frequency connectors part 37: sectional specification stwx8 r.f. connectors1scopethis part of iec 61169, which is a sectional specification (ss), provides information and rules for the preparation of detail specifications (ds) for type stw x8 r.f. coaxial connectors with push-pull self-lock coupling.the connectors are normally used with flexible and semi-rigid r.f. cables for middle power applications in conjunction with 50 cables in an operating frequency range up to 4 ghz.it describes the interface dimensions for general purpose grade 2 connectors, dimensional details for standard test connectors, grade 0, together with gauging information and the mandatory tests selected from qc 220000 (iec 61169-1), applicable to all ds relating to type stw x8 connectors.this specification indicates the recommended performance characteristics to be considered when writing a ds and covers test schedules and inspection requirements.2normative referencesthe following referenced documents are indispensable for the application of this document. for dated references, only the edition cited applies. for undated references, the latest edition of the referenced document (including any amendments) applies.iec 60096 (all parts), radio-frequency cablesiec 61169-1:1992, radio-frequency connectors part 1: generic specification general requirements and measuring methodsamendment 1 (1996) amendment 2 (1997)3mating face and gauge information3.1dimensions - general connectors grade 2 (figure 1)all dimensions are in mm. all un-dimensioned pictorial configurations are for reference purpose only.note 1djnote 1u s f cbai txhrgnpez wkaanote 1note 1note 1q90 10lmccnote 4vlmeeqddq m a miec 300/07cbbfigure 1 mating face of stwx8 connectors(for dimensions and notes, see table 1)table 1 mating face dimensionsreferencemmnotesmin.max.a8,128,20diameterb4,83,-diameterc2,062,21diameterd4,0-e5,335,84f-0,18g4,5-h-0,18i8,228,28diameterj6,907,00k-2,20l0,050,15radiusm-0,13radiusn-0,64diameterp1,321,37diameterq0,190,25r0,000,30s7,05-t-diameter (see note 2)u7,05-v6,00-w0,18-x-4,72-diameterz0,18-aa-diameter (see note 3)bb7,928,02diametercc1,221,42dd0,720,92ee1,10nominalnote 1 reference plane: mechanical and electrical.note 2 to meet electrical and mechanical requirements.note 3 bore diameter closed to meet electrical and mechanical requirements when mated with a1,32/1,37 diameter.3.2gauges for general purpose connectors - grade 2all dimensions are in mm. all undimensioned pictorial configurations are for reference purposes only.3.2.1gauges for socket contact50 104 mm (max.)cd3,17 mm (min.)iec 301/07figure 2 gauge pins for contact of socket connectors(for dimensions, see table 2)table 2 gauges dimensionsreferencegauge a-maximum material for sizing purposesgauge b minimum material for measurement of gauge retention forcemass of gauge: (80 1) gmmmmmin.max.min.max.d1,3701,3751,3151,320c00,64-material: steel, polished.surface roughness: ra=0,4 m maximum.test procedureaccording to 9.3.4 of iec 61169-1, the gauge a shall be inserted three times into the socket center contact. this is a sizing operation.after this, the gauge b shall be inserted into socket centre contact. the contact shall support the mass of the gauge in a vertical downward attitude.note the minimum diameter of gauge a corresponds to the maximum diameter of a male contact.3.2.2gauges for female outer contactradius or allow chamfera0,38 mm (max.)jack connector centerjcontact/insulator into the holereference planeiec 302/07(a) general dimensionsreference planereference plane90 10ccllqmmbbkq m a mqddiec 303/07(b) alternative coupling groovesfigure 3 gauge for outer of socket connectors(for dimensions, see table 3)table 3 gauge dimensionsreferencegauge c-maximum material for sizingpurposegauge d-minimum material formeasurement of gauge retention forcemmmmmin.max.min.max.a8,1858,208,128,135j7,057,157,057,15k1,11,1rad.l0,050,150,050,15radm-0,13-0,13q0,20,250,150,20bb7,957,987,957,98cc1,21,41,11,3dd0,60,80,50,7material: polished steel.surface roughness: ra =0,4 m max.test procedureaccording to 9.3.4 of iec 61169-1, the gauge c shall be placed three times inside the outer contact. this is a sizing operation.the gauge d is placed inside the outer contact.the retention force of the gauge shall be 15 nminimum.3.3dimensions standard test connectors grade 03.3.1socket (female contact)note 1dj rcnote 1h e v x wy pzb q af hfigure 4 female contact(for dimensions and notes, see table 4)iec 304/07table 4 female contact dimensionsreferencemmnotesmin.max.a8,228,25diameterb4,674,72see note 3/diameterc2,162,18see note 4/diameterdsee note 2/diametere6f0,270,52h0,290,57j7,057,20p1,391,41diameterq7,787,82r00,30v2,132,18diameterw4,624,88x6,056,10y0,180,23z0,150,25note 1 reference plane: mechanical and electrical.note 2 diameter of outer conductor and length of uniform section of transmission line to giverequired characteristic impedance of 50 when checked using time domain reflectometer methods.note 3 dimension for use of ptfe dielectric having a dielectric constant of 2,02. use of ptfe is mandatory.note 4 bore diameter closed to meet electrical and mechanical requirements when mated with a1,35/1,37 diameter.3.3.2 plug (male contact)note 1jfdcbahrunote 1np60 1eiec 305/07figure 5 male contact(for dimensions and notes, see table 5)table 5 male contact dimensionsreferencemmnotesmin.max.a8,158,20diameterb4,884,93see note 3/diameterc2,132,18see note 2/diameterdsee note 2/diameteref0,040,24h0,09j6,957,00n0,30p1,351,37diameterr00,20diameteru0,100,20note 1 reference plane: mechanical and electrical.note 2 diameter of outer conductor and length of uniform section of transmission line to giverequired characteristic impedance of 50 when checked using time domain reflectometer methods.note 3 dimension for use of ptfe dielectric having a dielectric constant of 2,02. use of ptfe is mandatory.4quality assessment procedure4.1generalthe following subclauses provide recommended rating, performance and test conditions to be considered when writing a detail specification (ds). they also provide an appropriate schedule of tests with the pro-formal blank detail specification and instructions for the preparation of a detail specification.4.2rating and characteristics (see clause 6 of iec 61169-1 (qc 220000)the values indicated below are recommended for type stw x8 connectors and are given for the writer of the detail specification (see table 6). they are applicable to the condition when the connectors are fully mated.certain tests will usually not be required. w hen these tests are required appropriate values shall be entered in the detail specification at the discretion of the specification writer.table 6 rating and characteristicsrating and characteristicstest method iec 61169-1 (qc 220000)subclausevalueremarksdeviations form standard test methodelectricalnominal impedancefrequency rangegrade 2 connectors-flexible cable,straight styles-semi-rigid cable straight styles-right -angle stylesreflection factor 1)grade 2 connectors-flexible cable straight styles-flexible cable right angle styles-semi-rigid cable straight styles-semi-rigid cable right angle styles-component mounting styles-solder bucket and pcb mounting stylescenter contact resistance2)-initial-after conditioningouter conductor continuity 2) -initial-after conditioninginsulation resistance 2)-initial-after conditioningproof voltage at sea level 3) 4 )-cable 96iec-50-3-1,iec 50-3-7-cable 96iec50-5-1,iec50-5-2-semi-rigid 3,58 mm diameter-semi-rigid 6,35 mm diameterproof voltage at 4,4 kpa 3) 4)-cables 96ie50-3-1, iec50-3-7-cables 96iec50-5-1, iec50-5-2-semi-rigid 3,58 mm diameter-semi-rigid 6,35 mm diameterenvir

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

評論

0/150