版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡介
1、_和潤新城·暢遠(yuǎn) 3# 樓外墻保溫 施工方案編制人:審核人:審批人:-可編輯修改 -_目錄1 編制依據(jù) ·······································32 工程概況 &
2、#183;···································33 材料性能及要求 ············
3、183;·····················34 施工條件環(huán)境要求 ··························
4、183;·····55 施工機(jī)械及工具 ································56 工藝流程 ·········&
5、#183;·····························6 61 基層清理 ··················
6、83;····················762 吊順直線 ····························
7、·······763 配制水泥砂漿································764 水泥砂漿抹灰施工·······
8、183;·····················765 配制粘結(jié)砂漿 ··························
9、83;········766 排板 ·······································867 粘貼聚苯
10、板施工································968 施工要點(diǎn) ················
11、······················1069 特殊部位施工 ··························
12、·········12610 錨固件安裝 ·································19-可編輯修改 -_611 抹面層施工 ··
13、83;·······························19612 質(zhì)量控制 ················
14、3;···················207 人力資源管理 ·····························
15、;·······208 安全生產(chǎn)保證措施 ··································209 文明施工及成品保護(hù) ····
16、183;···························221、編制依據(jù)1.1 外墻外保溫施工技術(shù)規(guī)程(JGJ144-2004);1.2 筑節(jié)能工程施工質(zhì)量驗(yàn)收規(guī)范(GB50411-2007);1.3 筑裝飾裝修工程施工質(zhì)量驗(yàn)收規(guī)范(GB50210-2001);1.4和潤新城 .暢園 3# 、5#樓施工圖紙及施工組織設(shè)計(jì)。
17、2、工程概況本工程高層樓體外墻采用擠塑聚苯乙烯泡沫板為主要保溫隔熱材料,以粘、釘結(jié)合方式與墻身固定,抗裂砂漿復(fù)合耐堿玻纖網(wǎng)格布為保護(hù)增強(qiáng)層,涂料飾面的外墻保溫系統(tǒng)。3、材料性能及要求3.1保溫材料聚苯板( EPS板)的性能除符合絕熱用模塑聚苯乙烯泡沫塑料GB/T10801.1標(biāo)準(zhǔn)的規(guī)定外,還應(yīng)符合表1的要求。板的規(guī)格為1200mm×600mm×45mm,平頭式,阻燃型,其尺寸偏差應(yīng)符合表 2的要求。-可編輯修改 -_聚乙烯泡沫塑料棒用于填塞膨脹縫, 作為密封膏的隔離背襯材料, 其直徑按縫寬的1.4 倍選用。3.2 水泥拌合在膠粘劑和抹面膠漿中的水泥應(yīng)采用普通硅酸鹽水泥或低堿
18、硫鋁酸鹽水泥。普通硅酸鹽水泥應(yīng)符合硅酸鹽水泥、普通硅酸鹽水泥GB175的要求。硫鋁酸鹽水泥應(yīng)符合快硬硫鋁酸鹽水泥 JC933的要求。EPS板技術(shù)性能指標(biāo)表 1檢驗(yàn)項(xiàng)目技術(shù)指標(biāo)表觀密度, kg/m 318.022.0垂直于板面方向的抗拉強(qiáng)度, MPa0.10且破壞部位不得位于粘貼界面尺寸穩(wěn)定性( 700C,48h) ,%0.3導(dǎo)熱系數(shù), W/ (m·K )0.041壓縮性能(形變 10%), MPa 0.10氧指數(shù), %30燃燒性能燃燒等級E級自然養(yǎng)護(hù)42養(yǎng)護(hù)時(shí)間, d蒸汽養(yǎng)護(hù)( 600C)5-可編輯修改 -_EPS板尺寸允許偏差表2厚度板面平整長度寬度對角線差板邊平直檢驗(yàn)項(xiàng)目50&g
19、t;50度允許偏差+1.5+2.0+2.0±1.03.0±2.01.0(mm)3.3 專用聚合物粘結(jié)劑、抹面膠漿廠家已配制好,現(xiàn)場施工時(shí)加水用手持式電動攪拌機(jī)攪拌,重量比為水:聚合物砂漿等于1:5,可操作時(shí)間不小于2h。其中膠粘劑性能指標(biāo)應(yīng)符合 L07J110表3的要求,抹面膠漿應(yīng)符合L07J110表5的要求。3.4錨栓金屬螺釘應(yīng)采用不銹鋼或經(jīng)過表面防銹處理的金屬制成,塑料釘和帶圓盤的塑料膨脹套管應(yīng)采用聚酰胺、 聚乙烯或聚丙烯制成, 制作塑料釘和塑料套管的材料不得使用回收的再生材料。錨栓的有效錨固深度在混凝土墻中不小于25mm,在砌體墻中不小于 50mm,塑料圓盤直徑不小于
20、 50mm,單個(gè)錨栓抗拉承載力標(biāo)準(zhǔn)值不小于0.3KN ,且應(yīng)進(jìn)行拉拔力現(xiàn)場試驗(yàn)。3.5 耐堿玻纖網(wǎng)格布用于增強(qiáng)保護(hù)層抗裂及整體性;選用孔徑4mm×4mm的耐堿玻纖網(wǎng)格布,其性能指標(biāo)應(yīng)符合耐堿玻璃纖維網(wǎng)布JC/T841的要求外,還應(yīng)符合 L07J110表4的要求。4、施工條件環(huán)境要求4.1 施工條件主體驗(yàn)收通過,外墻已滿足施工工作面要求。-可編輯修改 -_材料進(jìn)場,施工隊(duì)伍已選定,并進(jìn)場。項(xiàng)目部對其進(jìn)行安全教育和安全、技術(shù)交底工作完畢。外用吊藍(lán)安裝調(diào)試完畢。相關(guān)材料產(chǎn)品合格證書、性能檢測報(bào)告等相關(guān)資料齊全,并合格。墻體節(jié)能工程使用的保溫隔熱材料進(jìn)場后,應(yīng)在監(jiān)理(建設(shè))單位的見證下取樣,
21、并送至有資質(zhì)的檢測機(jī)構(gòu)進(jìn)行進(jìn)場復(fù)驗(yàn)。進(jìn)場復(fù)驗(yàn)應(yīng)符合下列要求:1)復(fù)驗(yàn)項(xiàng)目1 、保溫材料的導(dǎo)熱系數(shù)、表觀密度、抗壓強(qiáng)度或壓縮強(qiáng)度和燃燒性能;2 、粘結(jié)材料的粘結(jié)強(qiáng)度;3、增強(qiáng)網(wǎng)的力學(xué)性能、抗腐蝕性能。2)檢驗(yàn)數(shù)量同一廠家、 同一品種產(chǎn)品, 當(dāng)單位工程建筑面積在20000m2以下時(shí)各抽查不少于3 次;當(dāng)單位工程建筑面積在20000m2以上時(shí)各抽查不少于6 次。4.2 環(huán)境要求外墻外保溫工程施工期間以及完工后24h內(nèi),基層及環(huán)境空氣溫度不應(yīng)低于5。夏季應(yīng)避免陽光曝曬。在5級以上大風(fēng)天氣和雨天不得施工。5、施工機(jī)械及工具5.1施工機(jī)械1外用吊藍(lán),選用 ZLP630型號吊籃。選用型號其主要參數(shù)如下:型號
22、ZLP630額定載荷 (kg)630升降速度 (m/min)9-11-可編輯修改 -_額定功率 (kW)1.5×2工作平臺尺寸長×寬 ×高(mn)6000× 690×1230配重 (kg)900外用吊籃應(yīng)有產(chǎn)品合格證書、出場證明等相關(guān)資料。2 根據(jù)現(xiàn)場要求計(jì)劃投入4臺上述外用吊籃就以滿足施工要求。這樣既可以滿足流水作業(yè),亦能保證施工進(jìn)度要求。5.2施工工具壁紙刀、電錘、手持式電動攪拌器、抹子、角抹子、靠尺、刷子、灰漿托板、拉線、米尺、毛輥、手錘、鉗子、電熱絲切割器、開槽器等。6、工藝流程基層清理 吊鐵絲順直線 (間距 1.5m)根據(jù)順直線打 2
23、0mm厚灰餅(間距 1.5× 1.5m) 配制 1:3水泥砂漿 水泥砂漿找平層施工 拌制粘結(jié)聚合物砂漿(膠粉聚苯顆粒保溫砂漿) 粘貼 45厚( 20厚)聚苯板 部分造型梁頂面及側(cè)面抹20厚膠粉聚苯顆粒保溫砂漿細(xì)部處理 鉆孔安裝固定件 擠塑板打磨、找平、清理中間驗(yàn)收 拌制面層聚合物砂漿 刷一遍界面劑 抹 3 5厚抹面膠漿中間壓入耐堿玻纖網(wǎng)格布分格縫內(nèi)填塞內(nèi)襯、封密封膠 驗(yàn)收6.1基層處理清理混凝土墻面上殘留的浮灰、 脫模劑油污等雜物及抹灰空鼓部位等。-可編輯修改 -_剔除剪力墻接槎處劈裂的混凝土塊、夾雜物、空鼓等,并重新進(jìn)行修補(bǔ);外墻各種洞口填塞密實(shí)。6.2吊順直線選擇無風(fēng)的好天氣在女
24、兒墻頂間距1.5米吊鐵絲線,并做好墻面 2cm的順直控制線,并在中間適當(dāng)位置固定以防止線太長因風(fēng)吹誤差過大。乘坐吊籠自上而下打灰餅,間距1.5×1.5m。6.3配制水泥砂漿施工時(shí)用砂漿攪拌機(jī)攪拌1:3的水泥砂漿。攪拌時(shí)間不少于2min,攪拌必須充分、均勻,稠度適中。水泥砂漿攪拌應(yīng)隨拌隨用,并應(yīng)在3h 內(nèi)用完。6.4水泥砂漿抹灰施工水泥砂漿拌制后應(yīng)自上而下分段抹灰施工,要求抹牢,應(yīng)無明顯抹紋。施工過程中不得垂直交叉作業(yè),嚴(yán)禁自下而上作業(yè)以防止施工過程中污染已施工完畢的墻體。抹灰24小時(shí)后檢查是否有空鼓現(xiàn)象。如有超過 200c空鼓,應(yīng)及時(shí)處理。 抹灰后的墻體平整度應(yīng)控制在 3以內(nèi)( 2米
25、范圍內(nèi))。并要求陰陽角方正、上下通順。6.5配制粘結(jié)砂漿施工使用的砂漿分為專用粘結(jié)砂漿、膠粉聚苯顆粒保溫砂漿及面層聚合物抗裂砂漿。施工時(shí)可用砂漿攪拌機(jī)或用手持式電動攪拌機(jī)攪拌,拌制的粘結(jié)砂漿重量比為水 :砂漿 =1:5,邊加水邊攪拌;攪拌時(shí)間不少于5min,攪拌必須充分、均勻,稠度適中,并有一定黏度。-可編輯修改 -_砂漿調(diào)制完畢后, 須靜置5min,使用前再次進(jìn)行攪拌, 拌制好的砂漿應(yīng)在 1h內(nèi)用完。6.6排版外墻部分粘貼保溫板的墻體和門窗洞口必須嚴(yán)格按要求進(jìn)行排版粘貼保溫板。洞口四角處的聚苯板應(yīng)采用整塊聚苯板切割成型,不得拼接。接縫距四角距離應(yīng)大于200,且必須有錨固措施。 (如圖 1)圖
26、1聚苯板墻體排板示意圖-可編輯修改 -_門窗洞口圖1 門窗洞口排板示意圖聚苯板下料按照事先排好的尺寸切割擠塑板(電熱絲切割器或壁紙刀切割)從拐角處垂直錯(cuò)縫連接,要求拐角處沿建筑物全高順直、完整。保溫板轉(zhuǎn)角排板施工如圖2。-可編輯修改 -_基層墻體找平層粘結(jié)劑006聚苯板1200圖2保溫板轉(zhuǎn)角排板示意圖6.7 粘貼聚苯板施工聚苯板施工采用點(diǎn)框粘法粘貼聚苯板施工。樣板墻施工由監(jiān)理單位和總包單位指定某一基面處理完成的樓層作為樣板層交與外保溫單位進(jìn)行樣板層施工。 擠塑板的粘貼應(yīng)從細(xì)部節(jié)點(diǎn) (如飄窗、陽臺、挑檐)及陰、陽角 部位開始向中間進(jìn)行。施工時(shí)要求在建筑物外墻所有陰陽角部位沿全高掛通線控制其順直度
27、(注:保溫施工時(shí)控制陰陽角的順直度而非垂直度) ,并要求事先用墨斗彈好底邊水平線及100mm 控-可編輯修改 -_制線,以確保水平鋪貼,在區(qū)段內(nèi)的鋪貼應(yīng)由下向上進(jìn)行。大面積施工樣板墻粘貼完畢經(jīng)監(jiān)理(建設(shè))單位驗(yàn)收合格后方可進(jìn)行大面積粘貼擠塑板施工。大面積保溫板的施工順序?yàn)樽韵露?,從角部開始粘貼,粘貼時(shí)要保證粘貼的質(zhì)量尤其是要保證打灰的質(zhì)量,要嚴(yán)格按照框點(diǎn)粘接要求施工。6.8 施工要點(diǎn)粘貼聚苯板前應(yīng)對墻體做粘貼試驗(yàn),試測按下述方法進(jìn)行:用外保溫系統(tǒng)膠粘劑粘貼聚苯板, 5分鐘后取下,并重新貼回原位,若仍能用手揉動即為合格,否則表明基層過干或吸水性過高。1對于基層墻體過干的應(yīng)噴水潤濕。施工過程中不
28、可過量噴水,不得向墻面潑水。2 對于潮濕或吸水性過高影響粘結(jié)強(qiáng)度和施工的基層必要時(shí)可涂刷界面劑或抹專用砂漿。粘貼聚苯板的板縫應(yīng)擠緊,相鄰板應(yīng)齊平,施工時(shí)控制板間縫隙不得大于1.6mm,板間高差不得大于1.0mm。當(dāng)板間縫隙大于1.6mm 時(shí),須用擠塑板條將縫塞滿,板條不得用砂漿或膠結(jié)劑粘結(jié);板間平整度高差大于1.0mm的部位應(yīng)在施工面層前用木銼、粗砂紙或砂輪打磨平整。用抹子在每塊擠塑板周邊涂50mm 寬專用聚合物粘結(jié)砂漿, 要求從邊緣向中間逐漸加厚,最厚處達(dá)10mm。并應(yīng)在擠塑板的下側(cè)留設(shè)50mm 寬的槽口, 以利于貼板時(shí)將封閉在板與墻體間的空氣溢出。然后再在擠塑板中間部位均勻布置8 個(gè)粘接點(diǎn)
29、,每點(diǎn)直徑不小于140mm,膠厚 10mm,中心間距 200mm,如圖 3所示。當(dāng)采用非標(biāo)-可編輯修改 -_準(zhǔn)尺寸的聚苯板時(shí),板面中間部位涂抹的膠粘劑一般為46個(gè)點(diǎn)。采用點(diǎn)框粘法膠粘劑的涂抹面積與聚苯板面積之比不得小于40%。膠粘劑圖3點(diǎn)粘法示意圖膠粘劑應(yīng)涂抹在聚苯板上, 而不是涂抹在基層墻體上, 聚苯板涂膠后應(yīng)及時(shí)粘貼,粘貼時(shí)應(yīng)輕柔滑動就位,不得局部用力按壓,造成板面受力不均而變形。聚苯板對頭拼縫應(yīng)擠緊,并與相鄰板面齊平,膠粘劑的壓實(shí)厚度宜控制在3 5mm,粘貼好后應(yīng)立即刮除板縫和板側(cè)面殘留的膠粘劑。聚苯板的施工應(yīng)有勒腳部位開始(距室外散水上表面20mm),自下而上,沿水平方向鋪貼,豎縫應(yīng)逐
30、行錯(cuò)縫1/2 板長,板件高差不得大于1.0mm,否則應(yīng)打磨平整后方可粘貼下一層。對于門窗口內(nèi)壁粘貼聚苯板的部位,其厚度應(yīng)視門窗框與洞口間隙大小而定,一般不宜小于 20mm。6.9 特殊部位施工-可編輯修改 -_發(fā)泡水泥磚專用防火隔離帶的設(shè)置施工(1) 根據(jù)規(guī)范規(guī)定和設(shè)計(jì)圖紙要求本工程保溫材料的燃燒性能不應(yīng)低于A1級。當(dāng)采用 A1級保溫材料時(shí),每層應(yīng)設(shè)置水平防火隔離帶。防火隔離帶的高度為窗上口至上一層樓板標(biāo)高處。高度為 300mm。(2)本方案防火隔離帶是采用發(fā)泡水泥專用防火隔離帶保溫材料,采用界面劑 + 發(fā)泡水泥專用防火隔離帶,并以抗裂砂漿為保護(hù)層,以耐堿玻纖網(wǎng)格布為增強(qiáng)層,并配以不同飾面層的
31、薄抹灰外墻外保溫做法?;緲?gòu)造示意圖如圖:(4.1;4.2):圖4.1-可編輯修改 -_圖4.2( 3)發(fā)泡水泥專用防火隔離帶系統(tǒng)施工工藝依據(jù)民用建筑外保溫系統(tǒng)及外墻裝飾防火暫行規(guī)定 預(yù)留好 300mm 高的防火隔離帶進(jìn)行基層處理吊垂直、 套方、彈控線用保溫材料做灰餅?zāi)ǖ谝槐闊o機(jī)保溫材料抹第二遍無機(jī)保溫材料抹抗裂砂漿鋪壓加強(qiáng)耐堿網(wǎng)格布抹第二遍(整體外墻保溫 )抗裂砂漿壓入耐堿網(wǎng)格布抗裂層驗(yàn)收保溫整體驗(yàn)收(4) .施工要點(diǎn)A、基層墻面處理1)徹底清除基層墻體表面浮灰、油污、脫模劑、空鼓及等影響墻面施工的物質(zhì),墻體表面突起物 10mm 時(shí)應(yīng)剔除。2)對于粘土磚墻一般只需將表面浮灰、白灰等清除,澆水
32、潤濕即可,對于混凝土墻體-可編輯修改 -_和砌筑填充加氣混凝土墻體應(yīng)噴涂界面砂漿。B、保溫層施工準(zhǔn)備1)吊垂直、套方找規(guī)矩、彈厚度控制線,拉垂直,水平控制線。2)按設(shè)計(jì)要求的保溫層厚度,用無機(jī)?;⒅樯皾{打點(diǎn)做標(biāo)準(zhǔn)厚度灰餅,沖筋,以控制保溫層的厚度。(3)C、保溫層施工 :1)預(yù)留 300mm 防火隔離帶時(shí),可用50mm 寬 300mm 高的擠塑板滿抹粘結(jié)砂漿粘貼在防火隔離帶處支撐其上層部分的擠塑板。2)抹無機(jī)保溫砂漿保溫層施工至少分2-3 遍,每遍所抹保溫漿料為10-20mm,首遍施工厚度宜控制在 10mm 左右,注意壓實(shí),最后一遍施工厚度宜控制在10mm 左右,每兩遍施工間隔應(yīng)在 24h
33、以上,施工溫度偏低時(shí),間隔時(shí)間可延長。3)發(fā)泡水泥專用防火隔離帶施工應(yīng)自上而下。4)最后一遍無機(jī)玻化微珠保溫層施工時(shí)應(yīng)達(dá)到灰餅沖筋厚度,并用大杠搓平,使墻面、門窗口平整度達(dá)到要求,注意保溫漿料涂抹時(shí)應(yīng)壓緊壓實(shí)。5)配制好的保溫漿料應(yīng)在4 小時(shí)內(nèi)用完,大杠刮落的保溫漿料必須在4 小時(shí)內(nèi)經(jīng)攪拌后重新使用,嚴(yán)禁使用過時(shí)的保溫漿料。6)保溫層固化干燥后(用手按不動表面,約2-3d),方可進(jìn)行下一道工序施工,如環(huán)境溫度較低時(shí),養(yǎng)護(hù)時(shí)間宜延長。C、抗裂層施工 :1) 防火隔離帶抹抗裂砂漿鋪壓加強(qiáng)耐堿網(wǎng)格布施工時(shí)網(wǎng)格布高度上下加200mm。用抹子先在無機(jī)保溫漿料及其上下200mm處抹上一遍 2-3mm 抗裂
34、砂漿,立即漿網(wǎng)格布壓入抗裂砂漿中。網(wǎng)格布水平搭接處采用干茬搭接的方法。-可編輯修改 -_2)因防火隔離帶處要做加強(qiáng)網(wǎng),為避免整個(gè)外墻保溫體系平整度誤差過大,可將無機(jī)保溫漿料防火離帶上下200mm 的保溫板用鐵刷子挫下2-3mm 的厚度。3)待防火隔離帶及大面保溫板粘貼完畢并釘入錨固件后可按整個(gè)外墻保溫抗裂層施工方法進(jìn)行整體抗裂層施工。洞口加強(qiáng)網(wǎng)格布設(shè)置施工在門窗洞口等位置預(yù)先粘貼板邊翻包網(wǎng)格布,將不小于 250mm 寬的網(wǎng)格布中的100mm 寬用專用粘結(jié)砂漿牢固粘貼在基面上(粘結(jié)砂漿厚度不得超過2mm,)甩出 150后期粘貼擠塑板時(shí)再將網(wǎng)格布翻包過來。并沿門窗洞口四角 450方向增貼 300&
35、#215; 400的附加耐堿網(wǎng)布。 (如圖 5)在保溫工程施工過程中對裝飾線條的施工應(yīng)嚴(yán)格要求。對裝飾線條部位應(yīng)加強(qiáng)處理,處理方法如圖 7。標(biāo)準(zhǔn)網(wǎng)布圖7裝飾線條構(gòu)造-可編輯修改 -_標(biāo)準(zhǔn)網(wǎng)布門窗洞口A聚苯板洞口網(wǎng)格布加強(qiáng)圖基層墻體聚苯板標(biāo)準(zhǔn)網(wǎng)布搭接門窗洞口標(biāo)準(zhǔn)網(wǎng)布翻包標(biāo)準(zhǔn)網(wǎng)布A圖 5洞口網(wǎng)格布加強(qiáng)圖-可編輯修改 -_保溫隔熱樓面層防火隔離帶層高保溫隔熱樓面層防火隔離帶圖 6防火隔離帶示意圖在聚苯板粘貼施工的同時(shí)應(yīng)按圖紙要求對女兒墻頂部、飄窗板頂部、窗臺等有排水要求的部位進(jìn)行找破,坡度不小于2%。-可編輯修改 -_6.10 錨固件安裝擠塑板粘結(jié)牢固后,應(yīng)在 24h 后開始安裝固定件,錨固件錨入基
36、層墻體深度為,50mm,鉆孔深度應(yīng)為60(有抹灰層時(shí), 不包括抹灰層厚度)。數(shù)量布置如圖6。(1/4L )圖6錨固件布置示意圖6.11抹面層施工涂料飾面時(shí)抹面膠漿壓入耐堿網(wǎng)布1 將23厚抹面膠漿均勻抹在保溫層表面上(面積應(yīng)略大于一塊網(wǎng)格布的范圍),立即將裁好的耐堿網(wǎng)布用鐵抹子壓入抹面膠漿內(nèi),(玻纖網(wǎng)彎曲面應(yīng)朝向墻面)待膠漿干硬至可碰觸時(shí), 再抹上第二道抹面膠漿, 直至全部覆蓋玻纖網(wǎng) (不得露網(wǎng)),使玻纖網(wǎng)處于兩道膠漿的中間位置,抹面膠漿總厚度為35。2 洞口加強(qiáng)網(wǎng)的施工應(yīng)同上一起施工,加強(qiáng)網(wǎng)的放置詳圖如圖1。3 首層應(yīng)鋪貼雙層耐堿網(wǎng)布,第一層耐堿網(wǎng)布對接,第二層搭接(第二層網(wǎng)格布采用加強(qiáng)型),
37、兩層耐堿網(wǎng)布之間抹面膠漿應(yīng)飽滿。4 在首層墻面陽角處設(shè)2m高的專用金屬護(hù)角,護(hù)角應(yīng)夾在兩層耐堿網(wǎng)布之-可編輯修改 -_間。其余樓層陽角處兩側(cè)耐堿網(wǎng)布雙向繞角相互搭接,各側(cè)搭接寬度不小于 200。6.12質(zhì)量控制主要控制項(xiàng)目1 本系統(tǒng)所使用的所有材料質(zhì)量和技術(shù)性能均應(yīng)滿足有關(guān)國家標(biāo)準(zhǔn),行業(yè)標(biāo)準(zhǔn)及本規(guī)程的要求,應(yīng)檢查出廠合格證或進(jìn)行復(fù)檢。2 保溫層的厚度及構(gòu)造做法應(yīng)符合建筑節(jié)能設(shè)計(jì)要求,保溫層厚度應(yīng)均勻,不允許有超規(guī)程的正負(fù)偏差。3 保溫層與基層墻體以及各構(gòu)造層之間必須粘結(jié)牢固,無脫層,空鼓,裂縫。一般控制項(xiàng)目1 表面平整,潔凈,接茬平整,無明顯抹紋,無露網(wǎng)現(xiàn)象,線角應(yīng)順直,清晰,面層無起皮,爆灰等現(xiàn)象。2 底層外墻陽角需作護(hù)角,基余各層陰角,陽角以及門窗洞口四角等部位均需用網(wǎng)格布加強(qiáng)。3 墻面埋設(shè)暗線,管道后,墻面用網(wǎng)格布和抗裂漿加強(qiáng),表面抹灰平整。4 分格縫寬度與深度均勻一致, 平整光滑 ,棱角整齊,順直, 滴水線 (槽)流水坡向正確 ,且順直。7、 人力資源管理7.1 現(xiàn)場配備項(xiàng)目經(jīng)理一名,施工隊(duì)長一名,技術(shù)主管一名,技術(shù)員6名,質(zhì)檢員 1名,并對
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 教育培訓(xùn)機(jī)構(gòu)校長合同3篇
- 旅游代理加盟合同3篇
- 安裝工程合同的工程結(jié)算報(bào)告3篇
- 方程式賽車教練勞動合同范本3篇
- 工業(yè)門安裝工程合同書3篇
- 教育培訓(xùn)機(jī)構(gòu)入職勞動合同3篇
- 摩托車租賃合同范文簡版3篇
- 數(shù)據(jù)庫安全防護(hù)與信息服務(wù)3篇
- 工業(yè)設(shè)備購銷協(xié)議3篇
- 教育機(jī)構(gòu)合作協(xié)議范文3篇
- 愛國教育-我和我的祖國
- 24年注安-其他安全-必背考點(diǎn)-王培山
- 2024年北京版小學(xué)英語必背單詞表
- 2024年電大勞動與社會保障法期末考試題庫及答案
- 北師大版五年級上冊數(shù)學(xué)計(jì)算題大全1000道帶答案
- 電工二級技師試題及答案
- 中國成人心肌炎臨床診斷與治療指南2024解讀
- 高中英語外刊-小貓釣魚50篇
- 2024電化學(xué)儲能電站運(yùn)行維護(hù)管理規(guī)范
- 臨時(shí)用工施工合同模板
- 《電子吊秤校準(zhǔn)規(guī)范》公示件
評論
0/150
提交評論