1、目 錄CATALOGUE一、機(jī)組外觀(guān)和機(jī)組結(jié)構(gòu)1Unit outlook and structure二、系統(tǒng)流程圖3system flow chart三、機(jī)組安裝4Installation四、調(diào)試18Test五、使用20Operation六、維護(hù)和保養(yǎng)25Maintenance七、運(yùn)行圍26Run scope八、簡(jiǎn)易故障處理27Trouble disposal一機(jī)組外觀(guān)和機(jī)組結(jié)構(gòu) Unit outlook and structure工機(jī)組外觀(guān)1回風(fēng)口 air inlet2出風(fēng)口 air outlet3接水管排水孔drain pan weep hole4室內(nèi)外機(jī)連接口indoor & o
2、utdoor unit connection5底盤(pán)排水孔classic weep hole6電源線(xiàn)孔 power wire hole7壓力表 pressure gauge8控制面板control panel9室外機(jī) outdoor unit2.機(jī)組結(jié)構(gòu) Unit structure1 .壓縮機(jī) Compressor2 .電加熱 Electric heater3 .蒸發(fā)器 Evaporator4 .過(guò)濾網(wǎng)Filter9.球閥 Ball valve5 .風(fēng)機(jī)Fan6 .電控箱 Electric controller7 .電機(jī) MotorS.室外機(jī) outdoor unit注:1.單冷機(jī)使用毛細(xì)管節(jié)
3、流(50HP以下);For single cooling unit, capillary should be used to throttle.(below 50HP)2 .熱泵機(jī)使用膨脹閥節(jié)流,空內(nèi)機(jī)室外機(jī)各安裝一個(gè);For heat-pump unit, expansion valve is used to throttle, installing each one both in indoor and outdoor units.3 .氣液分離器安裝于室內(nèi)機(jī);Gas and Irquide separation is installed in indoor unit.以上三點(diǎn)示意圖上均未
4、表示.The three points above have not been shown in the sketch map.二,系統(tǒng)流程圖system flow chart1、風(fēng)冷冷風(fēng)型/電加熱型空調(diào)機(jī)工作原理Working principle of the air-cooled cooling or electric heating air conditioner蒸發(fā)器capillary毛.; 細(xì)算 管|vaporatorjointing pipe接管Tx卜ball valve球閥condenseraxial fan軸流風(fēng)機(jī)A冷凝器dryer-filter panel干燥過(guò)漁器joint
5、接頭jointing pipe接管ball valve球閥-Joutside室外側(cè)inside室內(nèi)側(cè)2、熱泵型空調(diào)機(jī)工作原理Working principle of the heat-pump air conditionerball valve球閥joint接頭gas and liquid separation compressor氣液分離器han室外換熱器electric heaterUo ,電V 加axial fan ;熱軸流風(fēng)棚,器fpur way valveA ball valve-rT 球閥_mjoint接頭outside室外側(cè)一爾縮機(jī)一_一 一 centrifugual fan e
6、xpansion vdfve 渴心風(fēng)機(jī) filter膨張莉 過(guò) 灌 器 ' -siglc dirction valve制熱循環(huán) heat cycle制冷循環(huán)refrigeration cycleinside室內(nèi)側(cè)inside l|eat exchanger室I內(nèi)I換 熱| 器1.低壓繼電器 low pressure relay2.高樂(lè)繼電器high pressure relay三,機(jī)組安裝1 .安裝空間:Installation space確保機(jī)組安裝位置周?chē)凶銐虻目臻g以備操作、維修之用,同時(shí)也要保證氣流循環(huán) 暢通,不受阻礙并且沒(méi)有短路。安裝空間尺寸參見(jiàn)下圖。In order to
7、ensure operation and maintenance convenient , enough space around the units must be ensured while installing . Air must flow freely without resistance and short circuit . Installation space size can be consulted as follows .型號(hào)modelABc3HP、5HPx 8HP、10HP50050012.5HP、15HP50080020HP. 24HP500800100025HP、3
8、0HP、40HP、50HP5001000100060HP. 70HP、 80HP、 100HP、11 OHP100015001500、注:假設(shè)A為無(wú)連接管側(cè).B為連接管例。Note: assume A not to be side of connecting pipe, B to be side of connecting pipe.2 .安裝定位 Installing location應(yīng)考慮電氣接線(xiàn)、室外機(jī)連接、排水管布置以及風(fēng)管連接的方便。確保地面平整、水 平,機(jī)組安裝后傾斜度不應(yīng)超過(guò)下圖要求。Must count for the convenience of electric wirin
9、g, connection of indoor and outdoor unit, arrangement of drain pipe and air duct connection while installation. Ensure ground to be flat and level, after installing/ unit gradient can not exceed the limit showed in following chart.地基應(yīng)有足夠的強(qiáng)度。機(jī)組重量和地腳螺釘固定位置參見(jiàn)以下各圖。Foundation should be intended enough. U
10、nit weight and the foot screw fixed position is showed as following charts .其它注意事項(xiàng):Other attentions(1)室外機(jī)組安裝位置要選擇適當(dāng),必須安裝在無(wú)日光照射、遠(yuǎn)離熱源的地方。Indoor and outdoor unit must be installed in the place which has no sunlight illuminated and far from heat resource.(2)室外機(jī)組安裝應(yīng)考慮對(duì)建筑物外觀(guān)的影響。The influence on the buildi
11、ng appearance must be considered when install the outdoor unit.(3)安裝安置應(yīng)盡量選在管路短、彎曲少、高差小的地方。Installation should be situated in places where the pipe is short, bends are few and the height difference is little.(4)室外機(jī)組的位置不在地面或樓頂平面而需懸掛在墻壁上時(shí),應(yīng)制作牢固可靠的支架。While outside unit is not installed on the ground or
12、the top plane, but hung on the wall, it must use the firm support.(5)室外機(jī)組出風(fēng)口不應(yīng)對(duì)準(zhǔn)強(qiáng)風(fēng)吹的方向,上面不應(yīng)有障礙物。若頂部空間不夠時(shí), 需安裝彎曲型導(dǎo)風(fēng)管將風(fēng)導(dǎo)向遠(yuǎn)處,以避免氣流短路而影響機(jī)組性能。The outside unit's air outlet couldn't be in the direction of strong breeze , and there won' t be obstacles above it . If the above space is not enough
13、, please install bending type wind duct to guide the wind to distance , avoiding that unit performance will be influenced by air flow short .(6)側(cè)出風(fēng)型室機(jī)安裝在空調(diào)房時(shí),除考慮安裝方便外,還要保證氣流合理,送風(fēng)均 勻。While side air outlet model indoor unit* s installation in the air conditioner room, except considering convenient ins
14、tallation, it should ensure air flow reasonably and air supply equably.(7)任(可惜蝦,室推由叼節(jié)裝裝在室外。In any case, the inside unit should not be installed outside.3 .安裝 Installation示例圖 demonstrationa.搬運(yùn).吊裝 Handling, hoisting機(jī)組可用鏟車(chē)或吊車(chē)運(yùn)輸,吊裝時(shí)應(yīng)如下圖進(jìn)行操作。Unit can be transported by forklift or hoistr please operate as
15、 the followingchart while hoist.必須大于60'包裝箱底架 paking box chasismust large than 60°注意事項(xiàng) Attentions(1)吊裝前應(yīng)檢查機(jī)體吊環(huán)是否旋緊,纜繩是否安裝牢固。Before hoisting, should ensure the organism rings tightened, the hawsers fastened. 搬運(yùn)或吊裝過(guò)程中,應(yīng)保持機(jī)體平衡,切勿突然升高、降低5捌烈晃動(dòng)。During handling or hoisting, keep organism balance, d
16、on' t rise, drop suddenly or sway violently.b.管路布置 Pipes arrangement連接管路的布置須根據(jù)現(xiàn)場(chǎng)情況參照以下原則進(jìn)行:Connection pipe arrangement must according to the site1 s condition and refer to the following principles:(1)盡可能縮短連接管長(zhǎng)度,最好在5m以Try to shorten the length of connection pipe, best within 5m.每4、6米設(shè)1個(gè)存油彎.室外機(jī)Out
17、door unitb.室外機(jī)置于室內(nèi)機(jī)之上Outdoor unit higher than indoor unit。(2)盡可能減小室外機(jī)高度差。Try to shorten the altitude difference between indoor and outdoor units.(3)盡可能減少連接管路的彎頭數(shù)。Try to reduce the joint1 s amount used for connection if possible.(4)連接管長(zhǎng)超過(guò)20米時(shí),需檢查系統(tǒng)的潤(rùn)滑油是否足夠,必'要時(shí),需適當(dāng)增加。When pipe longer than 20m, in
18、spect lube whether it is enough, add it when necessary.當(dāng)室外機(jī)高度不同時(shí),參照下圖進(jìn)行管路布置。If indoor and outdoor unit s altitudes are difference, arrange the pipeline according to following graph .液管(即細(xì)管)liquid pipe (thinner pipe )氣管(即粗管)gas pipe (thicker pipe )c.室外機(jī)置于室內(nèi)機(jī)之下(壓縮機(jī)在室內(nèi)機(jī))Outdoor unit lower than indoor u
19、nit, compressor is in inside unit.室外機(jī)連接管的高差、管長(zhǎng)及彎頭數(shù)按下表限制:Altitude difference, pipe length and elbow' s amount of connection pipe ofindoor and outdoor unit defined by following table :c.連接步驟 Connection steps(1)工具準(zhǔn)備 Preparing tools一切工具、備件、材料必須準(zhǔn)備齊全,如沖擊鉆、真空泵、氮?dú)馄?、配管工具、?冷劑壓力表等。All tools, reserve parts
20、 and materials must be prepared all in readiness, for example : Percussion drill vacuum pumpr nitrogen cylinder, pipe-fit tools, refrigerant gauge and so on .室機(jī)安裝 Indoor unit installation參照前述要求安裝固定室機(jī)。Install and fix indoor unit according to above demands .(3)室外機(jī)安裝 Outdoor unit installation參照前述要求安裝固定
21、室外機(jī)。Install and fix outdoor unit according to above demands .室外機(jī)型號(hào) Outdoor unit modelSW-3NSW-(4X2)NSW-3RNSW-5NSW-(5X2)NSW-5RNSW-8NSW-(6X2)NSW-8RNSW-10NSW-10RNSW-13NSW-13RNSW-15NSW-15RNSW-20NSW-20RNSW-25NSW-25RNSW-30NSW-30RNSW-60NSW-70NSW-80N最大管長(zhǎng)Max.pipe length20203030405050505050最大高度差Max.Altitude do
22、ffs.10101515202525252525最多彎頭數(shù)(90°。Max.elbow.meter6688101212121212(4)打墻孔 Drill holes in wall在墻底部打圓孔或長(zhǎng)方形孔,以穿過(guò)連接管、排水管、電線(xiàn)等。Drilling round or square holes in the bottom wall to let connecting pipe, water drain pipe and wires cross .(5)管路連接 Connecting pipes申菱牌風(fēng)冷系列空調(diào)機(jī)管路連接方式有兩種:小于或等于LF/LFD29N以及 LF/LFD5
23、8N. LF/LFD85N機(jī)組采用喇叭口連接,其它類(lèi)型機(jī)組采用焊接方式連接。 連接時(shí)須注意以下幾點(diǎn):There are two methods to connect pipes of SHENLING'1 air-cooled series air conditioner: Flared-tube connection is for units smaller than LF/LFD29N and LF/LFD58N/ LF/LFD85N. And welding connection is for the other units. The following points must
24、be paid attention to while connecting;喇叭口連接方式Way of flared-tube connection(a)盤(pán)管展開(kāi)時(shí)采用反繞的方法緩慢進(jìn)行,避免折扁銅管。Unfold coiled pipe slowly by way of twisting in reverse, so as not to bend the copper tube flatted.(b)管道的彎曲加工用彎管器進(jìn)行,彎曲半徑較大時(shí)也可用手緩慢地彎曲。彎曲半徑過(guò)小,容易造成管子損壞,彎曲半徑限度要求不小于銅管外徑的6倍。Use tube bender to bend machine
25、ry pipe or bend by hand when the radius of curvature is larger . If the radius of curvature is too little, pipes may be miner than 6 times of the pipes external diameter.(c)松開(kāi)角閥連接處螺母,卸下連接管堵頭,在喇叭處涂上冷凍油,快速地將兩者 連接起來(lái)(要求5分鐘),喇叭口位置對(duì)好之后,再用板手緊固螺母。Loosen nut and remove the plug from eagle valve, then smear t
26、he flared with refrigerant oil and connect the two parts together quickly (in 5 minutes), when the flare' s seat well, then tighten the nut using spanner.(d)當(dāng)所需要管長(zhǎng)超過(guò)5m時(shí),需按要求加長(zhǎng)銅管并補(bǔ)充制冷劑If connecting pipe is longer than 5m, increase the length of the copper pipe and add refrigerant.焊接方式: Way of wel
27、ding connection(a)采用硬釬焊連接所有接頭。Connect all joints by braze welding.(b)銅管切割后須清除毛刺及管異物。Get rid of the bur and foreign matter in pipe after cutting the copper tube.(c)焊接時(shí)管必須充氮。Fill tube with nitrogen when welding.(6)充氮試漏Charge with nitrogen to have leakage test銅管連接之后,從接頭處制冷劑充注口(喇叭口連接式在角閥上,焊接式須打開(kāi)所 有室側(cè)球閥,
28、再?gòu)氖覚C(jī)制冷劑充注口充氮)充入氮?dú)庵?.5Mpa ,用肥皂液檢查連 接管各接頭處是否有漏,若有漏,接頭必須重新處理。注意:切勿用氧氣或乙快氣試漏!After connecting copper pipe, charge with nitrogen to the pressure of 1.5MP through charging valve at the joint (the charge valve of flared connecting type is at the eagle valve, but as to welding connecting type, all indoor si
29、de ball valve must be opened, then charge nitrogen through the charge valve of indoor unit). And using soapsuds to check every joint of the connection pipe to see if there is any leakage or not, if it is, the joint must be dealt with again .CAUTIONS: Be sure not to do leakage test with oxygen or ace
30、tylene.(7)空氣排除 Air discharge充氮試漏之后,必須排除管道空氣。因系統(tǒng)空間較大,建議采用真空泵抽除管道空 氣,不要采用放制冷劑方法來(lái)排除管道空氣。否則由于排除不凝性氣體不徹底會(huì)造 成系統(tǒng)高壓升高和制冷性能下降。Air in pipes must be removed after leakage test. As the system space is a little large, vacuum pump is suggested to draw air from the pipe, not to get rid of the air by charging pipe
31、with refrigerant or because incondensable gas can not be exhausted, the high pressure of system will rise and refrigerant rating performance descend.(8)真空檢漏 Vacuum leakage test抽真空至管絕對(duì)壓力1300Pa,保持5分鐘壓力無(wú)變化,否則接頭處有漏須重新處 理。抽真空時(shí),喇叭口連接式只需抽除管道空氣,焊接式必須開(kāi)啟室側(cè)所有球閥后 (因室機(jī)充有少量氮?dú)?,所以必須連同室機(jī)一起抽,但室外機(jī)球閥不能開(kāi)),再在空調(diào)機(jī) 制冷系統(tǒng)的高低壓
32、兩端制冷劑充注口分別抽除空氣,不能只抽一端。Achieve the vacuum in pipe (absolute pressure 1300Pa) and keep it for 5 minutes without pressure changing/ and if it changed, there must be a leakage in joints, so the joints must be dealt with again. Only the air in pipe need to be vacuumed for flared connecting type unit. But
33、 for welding connecting type unit all indoor side ball valves must be opened (because indoor unit has been charged with a little nitrogen, pipe must be vacuumed with indoor unit together, but ball valves of outdoor side can not be opened), the draw air separately from the charging valve of the refri
34、geration system in air conditioner, when vacuuming , pay attention not to vacuumone side only.(9)放出制冷劑 Let refrigerant out空調(diào)機(jī)出廠(chǎng)時(shí)制冷劑貯存在室外機(jī)。放出制冷劑時(shí)應(yīng)先打開(kāi)制冷劑液路兩個(gè)角閥 (或球閥),再打開(kāi)另兩個(gè)角閥(或球閥)。開(kāi)啟角閥時(shí)須注意,必須擰開(kāi)至上死點(diǎn)并略 擰緊,再蓋上防漏蓋帽。球閥只需將閥桿轉(zhuǎn)90°,(閥桿上有箭頭指示流動(dòng)方向)再蓋 上防漏蓋帽。所有閥都打開(kāi)之后,須將原"全關(guān)"掛牌換為"全開(kāi)"掛牌。Refr
35、igerant is stored in outdoor unit when air conditioner leaving factory . Open eagle valve ( or ball valve)f which is thinner pipe' s valve, in refrigerant liquid pipe of every system first when letting refrigerant out, then open other two eagle or ball valve . While opening eagle valve, the valv
36、e rod must be opened to the top dead center and tighten a little, then leak proof cup must be fitted. For ball valve, turn the rod to the eagle of 90° (there is arrow indicating turning direction) and fit the leak proof cap . After all valve opened, change the hanging plate "Close all"
37、; to "Open all”(10)復(fù)查接口泄漏 Check again the joints leakage閥門(mén)開(kāi)啟之后,用鹵素檢漏儀或肥皂液在接口處復(fù)查有無(wú)泄漏。After valves opened, use halide leak detector or soapsuds to check thejoints .(11)電線(xiàn)連接 Connecting electrical wires用多芯電纜線(xiàn)連接室外機(jī)接線(xiàn)端子。Use multiple core cable with every conductor/ s section being to connect indoor a
38、nd outdoor terminals .注意:每臺(tái)室外機(jī)必須按序號(hào)和相對(duì)應(yīng)的制冷系統(tǒng)的電路部分進(jìn)行連接,切勿接錯(cuò), 否則空調(diào)機(jī)不能正常運(yùn)行。Note : Each outdoor unit must connect with electrical branching of corresponding refrigeration system according to the number, if in disorder, the air conditioner cannot operate normally .(12)包扎 Wrapping up連接銅管包好保溫層之后(僅對(duì)焊接方式而言,喇
39、叭口方式銅管上已套好保溫管), 將銅管、電線(xiàn)等用塑膠帶妥善包扎并固定好。After connection copper pipe binding up the thermal insulation (only for welding way connection for flared tube connection, the pipe has been cased with insulation layer) . Then bind up pipesf wires, etc. with plastic tape and tighten them .4 .制冷劑補(bǔ)充 Supplementing
40、refrigerant當(dāng)連接管路超過(guò)5m時(shí),必須補(bǔ)充制冷劑(R22),請(qǐng)用戶(hù)安裝時(shí)參照下表進(jìn)行 補(bǔ)充。停機(jī)時(shí)補(bǔ)充制冷劑可從角閥冷劑充注口充入,開(kāi)機(jī)時(shí)補(bǔ)充制冷必須從壓縮機(jī) 吸氣口(即低壓端,壓縮機(jī)較粗的接管)冷劑充注口吸入,此時(shí)冷劑罐不宜倒置,以 保證制冷劑以氣體方式吸入壓縮機(jī),避免壓縮機(jī)發(fā)生液擊而受到損壞。When connecting pipe is in excess of 5m, refrigerant (R22) must be supplemented while user installing . Please refer to following table. When unit
41、 is not working, refrigerant can be charged from charge plug at angle valve, if the air conditioner is operating, refrigerant must be charged from the plug of compressor' s drawing side (lower pressure side, thicker connecting pipe of compressor), at this moment the refrigerant can be drawn into
42、 compressor as gas, for preventing the compressor from damaging because of liquid shocking .室外連接管長(zhǎng)每增加lm時(shí)制冷劑補(bǔ)充量表Table of the quantity of supplementary refrigerant when connecting pipe in different length室外機(jī) 型號(hào)SW-3NSW-(4X2)NSW-3RNSW-5NSW-(5X2)NSW-5RNSW-8NSW-(6X2)NSW-8RNSW-10NSW-10RNSW-13NSW-13RNSW-15N
43、SW-15RNSW-20NSW-20RNSW-25NSW-25RNSW-30NSW-30RNSW-60NSW-70NSW-80N每米管 長(zhǎng)制冷 劑量kg0.110.110.180.180.260.260.370.370.511.021.31制冷量修正系數(shù) Correcting coefficient of cooling capacity當(dāng)室外機(jī)連接管長(zhǎng)過(guò)長(zhǎng)或兩機(jī)高低差過(guò)大時(shí)會(huì)影響制冷能力,制冷量的修正系數(shù)參見(jiàn)下 表。Cooling capacity will be influenced when connecting pipe of indoor and outdoorunit is too
44、 long or the altitude difference of the two units is too large . Thecorrecting coefficient is listed in following table .制冷量修正系數(shù) correcting coefficient of cooling capacity等效總長(zhǎng) equivalent total length5m10m15m20m25m30m35m40m45 m50m有低差 Altitude differenceOm1.00.980.960.940.920.900.880.860.840.82(室機(jī)低于室外
45、機(jī)時(shí))5m1.00.970.950.930.910.890.870.850.830.81(When indoor10m0.960.940.920.900.880.860.840.820.80Unit higher than outdoor15m0.930.910.890.870.850.830.810.79Unit or indoor20m0.900.880.860.840.820.800.78Lower than outdoor unit)25m0.870.850.830.810.790.77高低差A(yù)ltitudedifference0m1.00.980.960.940.920.900.88
46、0.860.840.82(室機(jī)商于室外機(jī)時(shí))5m1.00.980.960.940.920.900.880.860.840.82(When indoor10m0.980.960.940.920.900.880.860.840.82Unit lower than outdoor15m0.960.940.920.900.880.860.840.82Unit or indoor20m0.940.920.900.880.860.840.82Higher than outdoor unit)25m0.920.900.880.860.840.82注:等效總長(zhǎng)指直管總長(zhǎng)再加上彎頭及存油彎的等效長(zhǎng)度之和。彎頭及
47、存油彎的等效長(zhǎng)度參見(jiàn)下表。Note : The "equivalent total length/r is the straight tubes total length added with equivalent of the elbows and the oil-kept bends. Equivalent length of the elbows and the oil-kept bends refers to following table .彎頭和存油彎等效長(zhǎng)度表(m)Table of equivalent length of the elbows and the oil-
48、kept bends (m)氣體連接管外徑mmGas connection pipe' s external diameter彎頭Elbow存油彎Oil-kept bends(pl5.88(5/8")0.32.0(pl9.05(3/4”)0.352.4(p22.2(7/8a,)0.403.0q>28(9/8-)0.53.7(p35(ll/8")0.554.1(p42(13/8")0.604.85 .排水管安裝Installing drainpipe接水盤(pán)排水孔和底盤(pán)排水孔接頭如下:Joints of drain pan weep hole and c
49、hassis weep hole seen as following :LF/LFD/RF8N LF/LFD68N /RF67N 螺紋接頭 G1HALF/LFD/RF8N LF/LFD58N /RF67N internal screw G"1ALF/LFD85N/RF83N LF/LFD305 外螺紋接頭 G1"ALF/LFD85N/RF83N LF/LFD305external screw G1A排水管安裝如圖所示.注意事項(xiàng):Attention 排水管走管位置始終不能高過(guò)達(dá)室機(jī)排水孔位置,同時(shí)室機(jī)另一側(cè)排水孔必須用絲堵堵死。冷凝水排至下水道路中需加設(shè)U形彎(見(jiàn)圖)以防臭氣
50、吸入空調(diào)機(jī)。The drain pipe cannot be higher than the water outlet hole of indoor unit, and the other side' s drain water hole must be blocked with screw stopper. If condensed water is to be drained to sewer, the drain pipe must have U shaped bend so as to prevent bad smell from going into air conditio
51、ner.6 .電G接線(xiàn) Electric wiring接線(xiàn)示意圖 wiring demonstration正確的接線(xiàn)按下圖所示:The correct wiring is showed in the below chart.3N780V 50Hzbreak空湖唯昭器Indoor unitllllONDCFF w ! 11 in J!:a.斷路器選用 Breaker selection 機(jī)外接線(xiàn)最關(guān)鍵是斷路器的選用。斷路器又稱(chēng)自動(dòng)空氣開(kāi)關(guān),主要是在電路條件下不 頻繁接通和分?jǐn)嗉爱?dāng)電路中發(fā)生超限的過(guò)載、短路及失壓時(shí)能自動(dòng)分?jǐn)嚯娐分?。?路器分框架式和塑料外殼式兩大類(lèi)??照{(diào)機(jī)安裝一般使用DZ系列塑
52、料外殼式斷路器, 用作機(jī)組電源的接通和分?jǐn)嘀?。The key to the out-of unit wiring is the breaker selection .Breaker, which is also named automatic air-breaker switch, can be used to engage in unfrequented connection and breaking normal circuit condition . In addition, breaker can auto-break the circuit while it happened to
53、o much overload, short-circuit and under tension . Breaker can be sorted into two types : frame type and plastic shell type . Generally, the air conditioner installation adopts DZ series shell breaker, in order to connect or break the unit power .斷路器選擇的一般原則如下:General principles of breaker selection
54、:(1)斷路器的額定電壓不低于線(xiàn)路的額定電壓。Breaker1 s rated voltage mustn1 t lower than the circuit rated voltage .(2)斷路器的額定電流不低于通過(guò)它的計(jì)算電流。Breaker's rated current mustn11 lower than its computing current which through it. (3)斷路器的類(lèi)型應(yīng)符合安裝、設(shè)備性能和操作方式的要求。Breaker's type must accord with the installation, plant perform
55、ance and operation1 s demand .b.電源導(dǎo)線(xiàn)選用 Selection of supply conductor導(dǎo)線(xiàn)用于連接電路,選用一般原則如下:Conductors are used to connect the circuit, selection principle as follows : 滿(mǎn)足發(fā)熱條件 Satisfy heating term導(dǎo)線(xiàn)在通過(guò)計(jì)算電流時(shí),具發(fā)熱溫度不能超過(guò)允許最高溫度。While the computing current pass through the conductor, its temperature should not be higher than maximal temperature allowed .(2)電壓損耗 Voltage loss導(dǎo)線(xiàn)通過(guò)計(jì)算電流時(shí),其產(chǎn)生的電壓損耗不應(yīng)超過(guò)正常允許的電壓損耗值。While the computing current pass through the conductor, the voltage loss should not b
溫馨提示
- 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶(hù)所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶(hù)上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶(hù)上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶(hù)因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 農(nóng)村土地流轉(zhuǎn)風(fēng)險(xiǎn)評(píng)估與保障協(xié)議
- 無(wú)人駕駛技術(shù)投資協(xié)議
- 汽車(chē)租賃長(zhǎng)租合同
- 公司股份改制方案設(shè)計(jì)報(bào)告
- 農(nóng)村綠化景觀(guān)改造施工協(xié)議
- 水務(wù)工程聯(lián)合運(yùn)營(yíng)合作協(xié)議
- 小英雄雨來(lái)成長(zhǎng)征文
- 國(guó)際貿(mào)易市場(chǎng)走勢(shì)預(yù)測(cè)分析表
- 迪士尼動(dòng)畫(huà)海洋奇緣觀(guān)后感
- 高考數(shù)學(xué)專(zhuān)題06四邊形的綜合問(wèn)題測(cè)試題
- 高中主題班會(huì) 悟哪吒精神做英雄少年-下學(xué)期開(kāi)學(xué)第一課主題班會(huì)課件-高中主題班會(huì)課件
- 2025電力物資檢儲(chǔ)配一體化建設(shè)技術(shù)導(dǎo)則
- 新學(xué)期 開(kāi)學(xué)第一課 主題班會(huì)課件
- 2025年協(xié)議離婚夫妻模板
- 福建省龍巖市2024-2025學(xué)年九年級(jí)上學(xué)期期末語(yǔ)文試題(解析版)
- 2025-2030年中國(guó)高爾夫產(chǎn)業(yè)規(guī)模分析及投資前景規(guī)劃研究報(bào)告
- 民法典合同編講座
- DBJ51-T 198-2022 四川省既有民用建筑結(jié)構(gòu)安全隱患排查技術(shù)標(biāo)準(zhǔn)
- 《干細(xì)胞及其應(yīng)用》課件
- 課題申報(bào)書(shū):生成式人工智能提升中小學(xué)教師數(shù)字素養(yǎng)的路徑探究
- 臨床婦產(chǎn)題庫(kù)+參考答案
評(píng)論
0/150
提交評(píng)論