1、Move Data Operation When the MOVE instruction receives power flow, it copies data as individual bits from one location in PLC memory to another. Because the data is copied in bit format, the new location does not need to be the same data type as the original. When the MOVE instruction receives power
2、 flow, it copies data from input operand IN to output operand Q as bits. If data is moved from one location in discrete memory to another, for example, from %I memory to %T memory, the transition information associated with the discrete memory elements is updated to indicate whether or not the MOVE
3、operation caused any discrete memory elements to change state. Data at the input operand does not change unless there is an overlap in the source and destination. Note: If an array of BOOL-type data specified in the Q operand does not include all the bits in a byte, the transition bits associated wi
4、th that byte (which are not in the array) are cleared when the Move instruction receives power flow. The input IN can be either a variable providing a reference for the data to be moved or a constant. If a constant is specified, then the constant value is placed in the location specified by the outp
5、ut reference. For example, if a constant value of 4 is specified for IN, then 4 is placed in the memory location specified by Q. If the length is greater than 1 and a constant is specified, then the constant is placed in the memory location specified by Q and the locations following, up to the lengt
6、h specified. Do not allow overlapping of IN and Q operands. The result of the MOVE depends on the data type selected for the instruction, as shown below. For example, if the constant value 9 is specified for IN and the length is 4, then 9 is placed in the bit memory location specified by Q and the t
7、hree locations following: The MOVE instruction passes power to the right whenever it receives power. Examples Example 1Whenever %I00003 is set, the three bits %M00001, %M00002, and %M00003 are moved to %M00100, %M00101, and %M00102, respectively. Coil %Q00001 is turned on.Example 2V_M00001 and V_M00
8、033 are both WORD arrays of length 3, for a total of 48 bits in each array. Since PLCs do not recognize arrays, the Length operand has to be set to 3, for the total number of WORDs to be moved. When enabling input V_Q0014 is ON, MOVE_WORD moves 48 bits from the memory location %M00001 to memory loca
9、tion %M00033. Even though the destination overlaps the source for 16 bits, the move is done correctly, except on Series 90-30 CPU351, CPU352, and CPU36x CPUs, which do not allow overlapping. MOVE_BOOL Operands Note: (PACSystems and Series 90-70.) HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucPro
10、ficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_IndirectRefs.htm Indirect referencing is available for all register references (%R, %P, %L, %W, %AI, and %AQ).Operand Data Type Memory Area Description Length Constant The length of IN; the number of bits to move. Valid range:If IN is a constant
11、: 1 Length 16.All other cases: PACSystems and Series 90-70: 1 Length 32,767; other PLC families: 1 Length 256.Default: 1.IN BOOL or WORD variable or constant, HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_Bit_Refs.htm bit reference in non
12、-BOOL variable HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_Data_Flow.htm data flow, HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_8_16_bit_vars_in_BOOL_mem.htm I, Q, M, T, S,
13、 G, R, P, L, AI, AQ, W, HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_Symbolic.htm symbolic, HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/ej_plcvars_i_o_vars.htm I/O variableThe location
14、 of the first data item to move. An %I, %Q, %M, or %T reference address need not be byte-aligned, but 16 bits beginning with the reference address specified are displayed online. If IN is a constant, it is treated as an array of bits. The value of the least significant bit is copied into the memory
15、location specified by Q. If the Length is greater than one, the bits are copied in order from the least significant to the most significant into successive memory locations, up to the length specified. (PACSystems.) When you select a bit reference in a non-BOOL symbolic variable or I/O variable, ens
16、ure that the value IN+Length-1 does not exceed the total number of bits available in the symbolic variable or I/O variable. For example, if MySymbolic is a 16-bit variable, then the combination of values IN = MySymbolic.X10 and Length=8 is invalid because 10+8-1=17, but if MySymbolic is a symbolic a
17、rray of length 2, its total number of bits is 32 and the combination of values IN = MySymbolic.X10 and Length=8 is valid.Q BOOL or WORD variable, HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_Bit_Refs.htm bit reference in non-BOOL variabl
18、e HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_Data_Flow.htm data flow, HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_8_16_bit_vars_in_BOOL_mem.htm I, Q, M, T, SA, SB, SC, G,
19、R, P, L, AI, AQ, W, HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_Symbolic.htm symbolic, HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/ej_plcvars_i_o_vars.htm I/O variable The location of
20、 the first destination data item. An %I, %Q, %M, or %T reference address does not need to be byte-aligned, but 16 bits beginning with the reference address specified are displayed online. CPU Support MOVE_BOOL is supported for PACSystems CPUs, VersaMax CPUs, Series 90-70 firmware version 3.00 or lat
21、er CPUs, and Series 90-30 firmware version 3.00 or later CPUs. In VersaMax CPUs and in Series 90-30 CPU350, you can overlap MOVE_BOOL instructions. MOVE_DINTOperands Note: HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_IndirectRefs.htm Ind
22、irect referencing is available for all register references (%R, %P, %L, %W, %AI, and %AQ).Operand Data Type Memory Area Description Length Constant Length; the number of DINTs to move. 1 Length 32,767. IN DINT variable or constant HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%2
23、0EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_Data_Flow.htm data flow, R, P, L, AI, AQ. PACSystems also supports HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_8_16_bit_vars_in_BOOL_mem.htm I, Q, M, T, G, W, HYPERLINK mk:MSITStore:C:Program%20Fil
24、esGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_Symbolic.htm symbolic, HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/ej_plcvars_i_o_vars.htm I/O variable.The location of the first DINT to move Q DINT variable HYPERLINK mk:MSITS
25、tore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_Data_Flow.htm data flow, R, P, L, AI, AQ.PACSystems also supports HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_8_16_bit_vars_in_BOOL_mem.htm I, Q,
26、M, T, G, W, HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_Symbolic.htm symbolic, HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/ej_plcvars_i_o_vars.htm I/O variable.The location of the fir
27、st destination DINT CPU Support MOVE_DINT is supported for PACSystems CPUs and Series 90-70 CPUs. MOVE_DWORDOperands Note: HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_IndirectRefs.htm Indirect referencing is available for all register r
28、eferences (%R, %P, %L, %W, %AI, and %AQ).Operand Data Type Memory Area Description Length Constant Length; the number of DWORDs to move. 1 Length 32,767. IN DWORD variable or constant HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_Data_Flo
29、w.htm data flow, R, P, L, AI, AQ. PACSystems also supports HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_8_16_bit_vars_in_BOOL_mem.htm I, Q, M, T, G, S, SA, SB, SC, W, HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20
30、EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_Symbolic.htm symbolic, HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/ej_plcvars_i_o_vars.htm I/O variable.The location of the first DWORD to move Q DWORD variable HYPERLINK mk:MSITStore:C:Program%20FilesGE%20Fan
31、ucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_Data_Flow.htm data flow, R, P, L, AI, AQ. PACSystems also supports HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_8_16_bit_vars_in_BOOL_mem.htm I, Q, M, T, G, SA, SB, SC, W, HYPER
32、LINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_Symbolic.htm symbolic, HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/ej_plcvars_i_o_vars.htm I/O variable.The location of the first destination DW
33、ORD CPU Support MOVE_DWORD is supported for PACSystems CPUs and Series 90-70 CPUs. MOVE_INT Operands Note: (PACSystems and Series 90-70.) HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_IndirectRefs.htm Indirect referencing is available for
34、 all register references (%R, %P, %L, %W, %AI, and %AQ).Operand Data Type Memory Area Description Length Constant Length; the number of INTs to move. PACSystems and Series 90-70: 1 Length 32,767.Other PLC family types: 1 Length 256. IN INT variable or constant HYPERLINK mk:MSITStore:C:Program%20File
35、sGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_Data_Flow.htm data flow, HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_8_16_bit_vars_in_BOOL_mem.htm I, Q, M, T, G, R, P, L, AI, AQ, W, HYPERLINK mk:MSITStore:C:Program%
36、20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_Symbolic.htm symbolic, HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/ej_plcvars_i_o_vars.htm I/O variable The location of the first INT to move Q INT variable HYPERLINK mk:MS
37、ITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_Data_Flow.htm data flow, HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_8_16_bit_vars_in_BOOL_mem.htm I, Q, M, T, G, R, P, L, AI, AQ, W, HYPERLINK
38、 mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_Symbolic.htm symbolic, HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/ej_plcvars_i_o_vars.htm I/O variable The location of the first destination INTCPU
39、 Support MOVE_INT is supported for all GE FANUC CPUs. On Series 90-30 CPU351, CPU352, CPU36x, and CPU37x CPUs, MOVE_INT does not support overlapping of IN and Q parameters, where the IN reference is less than the Q reference. For example, with the following values: IN=%R0001, Q=%R0004, LEN=5 (words)
40、, the %R0007 and %R0008 contents will be indeterminate; however, using the following values: Q=%R0001, IN=%R0004, LEN=5 (words) will yield valid contents. MOVE_REAL Operands Note: (PACSystems and Series 90-70.) HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.C
41、HM:/EJs/EJ_PLCVars_IndirectRefs.htm Indirect referencing is available for all register references (%R, %P, %L, %W, %AI, and %AQ).Operand Data Type Memory Area Description Length Constant Length; the number of REAL data items to move. PACSystems and Series 90-70: 1 Length 32,767.Other PLC family type
42、s: 1 Length 256.IN REAL variable or constant HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_Data_Flow.htm data flow, R, P, L, AI, AQ. PACSystems also supports HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHel
43、pLDFUNC.CHM:/EJs/EJ_PLCVars_8_16_bit_vars_in_BOOL_mem.htm I, Q, M, T, G, W, HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_Symbolic.htm symbolic, HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/
44、EJs/ej_plcvars_i_o_vars.htm I/O variable.The location of the first REAL to move Q REAL variable HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_Data_Flow.htm data flow, R, P, L, AI, AQ. PACSystems also supports HYPERLINK mk:MSITStore:C:Prog
45、ram%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_8_16_bit_vars_in_BOOL_mem.htm I, Q, M, T, G, W, HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_Symbolic.htm symbolic, HYPERLINK mk:MSITStore:C:Program%20FilesGE
46、%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/ej_plcvars_i_o_vars.htm I/O variable.The location of the first destination REALCPU Support MOVE_REAL is supported for PACSystems CPUs, VersaMax CPUs, Series 90-70 floating-point CPUs, and Series 90-30 floating-point CPUs. MOVE_UINTOperands Note:
47、 HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_IndirectRefs.htm Indirect referencing is available for all register references (%R, %P, %L, %W, %AI, and %AQ).Operand Data Type Memory Area Description Length Constant Length; the number of U
48、INTs to move. 1 Length 32,767. IN UINT variable or constant HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_Data_Flow.htm data flow, HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars
49、_8_16_bit_vars_in_BOOL_mem.htm I, Q, M, T, G, R, P, L, AI, AQ, W, HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_Symbolic.htm symbolic, HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/ej_plc
50、vars_i_o_vars.htm I/O variable The location of the first UINT to move Q UINT variable HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_Data_Flow.htm data flow, HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelp
51、LDFUNC.CHM:/EJs/EJ_PLCVars_8_16_bit_vars_in_BOOL_mem.htm I, Q, M, T, G, R, P, L, AI, AQ, W, HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_Symbolic.htm symbolic, HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20Edition
52、HelpLDFUNC.CHM:/EJs/ej_plcvars_i_o_vars.htm I/O variable The location of the first destination UINT CPU Support MOVE_UINT is supported for PACSystems CPUs and Series 90-70 CPUs. MOVE_WORD Operands Note: (PACSystems and Series 90-70.) HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machin
53、e%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_IndirectRefs.htm Indirect referencing is available for all register references (%R, %P, %L, %W, %AI, and %AQ).Operand Data Type Memory Area Description Length Constant Length; the number of WORDs to move.PACSystems and Series 90-70: 1 Length 32,767.Other PLC
54、 family types: 1 Length 256.IN WORD variable or constant HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_Data_Flow.htm data flow, HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_8_
55、16_bit_vars_in_BOOL_mem.htm I, Q, M, T, S, G, R, P, L, AI, AQ, W, HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_Symbolic.htm symbolic, HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/ej_plc
56、vars_i_o_vars.htm I/O variable The location of the first WORD to move Q WORD variable HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_Data_Flow.htm data flow, HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelp
57、LDFUNC.CHM:/EJs/EJ_PLCVars_8_16_bit_vars_in_BOOL_mem.htm I, Q, M, T, SA, SB, SC, G, R, P, L, AI, AQ, W, HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machine%20EditionHelpLDFUNC.CHM:/EJs/EJ_PLCVars_Symbolic.htm symbolic, HYPERLINK mk:MSITStore:C:Program%20FilesGE%20FanucProficy%20Machi
58、ne%20EditionHelpLDFUNC.CHM:/EJs/ej_plcvars_i_o_vars.htm I/O variable The location of the first destination WORD CPU Support MOVE_WORD is supported for all GE FANUC CPUs. On Series 90-30 CPU351, CPU352, and CPU36x CPUs, MOVE_WORD does not support overlapping of IN and Q parameters, where the IN refer
59、ence is less than the Q reference. For example, with the following values: IN=%R0001, Q=%R0004, LEN=5 (words), the %R0007 and %R0008 contents will be indeterminate; however, using the following values: Q=%R0001, IN=%R0004, LEN=5 (words) will yield valid contents. Shift Bits Operation Shift LeftWhen
60、the Shift Left (SHIFTL_WORD) instruction receives power flow, it shifts all the bits in a word or group of words to the left by a specified number of places. When the shift occurs, the specified number of bits is shifted out of the output string to the left. As bits are shifted out of the high end o
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
- 4. 未經(jīng)權益所有人同意不得將文件中的內容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內容本身不做任何修改或編輯,并不能對任何下載內容負責。
- 6. 下載文件中如有侵權或不適當內容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 推動高標準辦學水平提升的實操方案
- 出售叉車門架子合同范例
- 出售塔吊電纜合同范本
- 利于甲方合同范例
- 買賣牛肉合同范本
- 2025年PLC行業(yè)市場趨勢分析報告
- 出售高欄貨車合同范本
- 農村房屋框架購買合同范本
- 2025年度水利工程合同索賠預防與糾紛處理機制
- 傳媒公司主播簽約合同范本
- 危險物品管理制度
- 門靜脈炎護理課件
- 重慶八中2024屆高三12月高考適應性月考卷(四) 語文試卷(含答案)
- 基礎研究成果向臨床轉化的實踐與挑戰(zhàn)
- 建筑構造(下冊)
- 電流互感器試驗報告
- 蔣中一動態(tài)最優(yōu)化基礎
- 華中農業(yè)大學全日制專業(yè)學位研究生實踐單位意見反饋表
- 付款申請英文模板
- 七年級英語閱讀理解10篇(附答案解析)
- 抖音來客本地生活服務酒旅商家代運營策劃方案
評論
0/150
提交評論