1、SPA_H14_1Capture Power Electronics Market Growth with New Power Device AnalyzerKeisuke Nakano, HSTD MarketingBob Zollo, PED MarketingB1506A Power Device Analyzer for Circuit DesignN6900, N7900 and N8900 Series Power systemRequirement for Power Electronics CircuitApril 2014SPA246 B1506A New Product I

2、ntroduction2Power Device “User”(R&D, QA or ing inspection in Equipment Maker)Small Form Factor with Higher FrequencyPower switching frequency is being increased in order to reduce cost by employing smaller parts. WBG device introduction spurs higher frequency trend.Low energy consumption Low power l

3、ossRequirement for less energy consumption and less heating drives lower power loss of deviceReliable DevicesHigher attention to power electronics circuit reliability. Drive-by-wire (from hydraulic control )Low-Ron SiC Smaller AC adapter by VHF switching Power devices working under frigid climateB15

4、06A Power Device Analyzer for Circuit DesignApril 2014SPA246 B1506A New Product Introduction3NewOne click to obtain all device parameters for power electronics circuit designIV parameters (Ron, BV, Leakage, Vth, Vsat)Capacitance and Gate charge (Ciss, Coss, Crss, Rg, Qg)Power loss evaluationThermal

5、Test (-50 to +250)Up to 3kV / 1500APower Device (Wafer)Power Device (Discrete)Power ModuleInverter / ConverterPower Electric CircuitTarget Customer: Positioning in Power Analyzer FamilyApril 2014SPA246 B1506A New Product Introduction4Device Maker: B1505AVery wide range (10kV / 1500A)Precision (pA le

6、akage, u Ron)On-wafer, GaN collapse optionFlexible & scalable configurationPower Device MakerPower Device UserDevice User : B1506AEasy-to-use and fully automated operationWide range : 3kV / 1500APower loss evaluation (Qg, Rg, Capacitances)Thermal Test capability (-50 to +250)Target Customer of B1506

7、AApril 17, 2014Beluga PC/PRC Launch Plan5Device User SegmentConsumer ElectronicsIndustry ElectronicsAutomotive & Auto componentEnergy GenerationHeavy industrial equipmentAerospace & DefenseApplication exampleAir-conditioner, Refrigerator,Inverter, Converter, AC servo,Motor control, inverter, charger

8、, generatorEnergy GenerationRailway, construction machineAirplane, radarMax. Current / Voltage50A / 600V1000A / 1200V600A / 600V1000A / 20kV6000A / 6.5kV1000A / 1200VCustomersSamsung, Phillips, GE, Emerson, Hitachi, Toshiba, Mitsubishi, LG, Siemens, HaierToshiba, Mitsubishi, Hitachi, Fuji Elec, Daik

9、in, Yaskawa, Siemens, Kawasaki, Emerson network power, Bombardier, Siemens, ALSTOMGM, Ford, Daimler, BMW, VW, Toyota, Nissan, Honda, Hyundai, Denso, Bosch, Continental, RockwellSMA, Power-one, Kaco, Advanced Energy, Fronius, Enphase Energy, Danfoss, Omron, RefuSol, SchneiderBombardier, Alstom, ABB,

10、Kawasaki Heavy Ind., Kobe steel, Komatsu, CSR, Schindler, IHI, Mitsubishi Heavy Ind. FANUC, KUKA, CaterpillarAirbus/EADS, Boeing, Bombardier, Embraer, Northrop, Lockheed, Raytheon, BAE, United Technologies,Target customers and their IssuesCaseCustomerIssue?How to solve1Power circuit designerCannot g

11、et the device parameters at the actual operating condition from the data sheetB1506As Datasheet characterization mode offers easy-to-use and fully automated operation for power device measurement2Power circuit designer developing higher switching frequency circuitCannot evaluate the switching loss a

12、nd driving loss of power devicesB1506A can measure the gate charge and capacitance parameters necessary for power loss 3 ing inspection engineer Takes long time to measure large number of devices with traditional curve tracer. Just I-V measurement cannot eliminate unreliable deviceB1506A can offer f

13、ully automated I-V and C-V measurement. It also have thermal test solution.DatasheetIm a circuit designer of inverter and choosing the right device for my circuit. Which device is better for my circuit? Can I compare many power devices under same operating condition? Issue1: My required parameters a

14、re not on the device datasheet.Issue2 : I need parameters under actual operating conditionCase 1 : Power circuit designer (1)I need the capacitance value at Vd=1000V but datasheet only shows the value at Vd=40VHow to solveFriendly datasheet style user interface allows quick device selection.Simple s

15、teps to perform device parameter measurementFully automated IV and CV test without manual connection change Plug in type adapterCase 1 : Power circuit designer (2)Datasheet2. Edit range4. Execute1. Edit conditions3. Select parameters to measureIm working for AC-DC converter for PC, my customer likes

16、 smaller adapter and I try to use higher switching frequency. However, in higher frequency, the evaluation of switching loss and driving loss e important.How can I evaluate power loss of devices? Just measuring the Ron is not effective nowadays.Case 2 : Power circuit designer developing higher switc

17、hing frequency circuit (1)B1506AMeasure key parameters for power loss and calculate device power loss to frequency Innovative capacitance selector automates Ciss, Coss, and Crss testInnovative Qg test method covers both low and high voltage devicesMFCMUDevice capacitance selectorHVSMUSwitchAC blocki

18、ng RDC blocking CAutomatic 3-terminal device capacitance testQg adapter for gate charge measurementPower Loss vs. frequency calculation by B1506AQg and Cxss measurementCase 2 : Power circuit designer developing higher switching frequency circuit (2)My circuit has to function correctly in mission cri

19、tical application under Wide range of operating temperatureWide range of operating voltage and currentHigh speed railway in a frigid climateDriving in the blazing sunWind power generation in heavy rainDevice characterization across wide range of operating condition (Voltage, Current, Temperature) is

20、 mandatory to ensure the circuit operationPrevent counterfeit or B-grade devices in the marketCase 3 : ing inspection (1)B1506Afactory solution for the thermal test capability from -50 to + 250,Docking interface to to inTEST ThermoStream as a standard optionThermal plate interface in standard test f

21、ixtureSoftware to control those thermal test solution and run the automatic measurement for multiple test parameters through temperature range.inTEST ThermoStream:-50 to +220, B1506A has standard option to connectinTEST Thermal plate:room temperature to +250, B1506A can put the thermal plate on fixt

22、ure as standard capabilitySoftware: to control temperature and to run automatic measurement for multiple device parameters through temperature range Temperature conditionCase 3 : ing inspection (2)Micromarket 1r for B1506A available in DVDB1506A DemonstrationGate Charge Measurement (Qg)Capacitance M

23、easurement (Ciss, Coss, Crss)Datasheet Characterization DemoThermal Test Demo (Video)B1506A SummaryApril 2014SPA246 B1506A New Product Introduction15ModelDescriptionPrice ($) *B1506A-H2120 A /3 kV / CV / Qg / Fixture Package125 kB1506A-H51500 A / 3 kV / C-V / Qg / Fixture Package145 kB1506A-H711500

24、A / 3 kV / C-V / Qg / Fixture Package165 kB1506A-T01Thermal Test Enclosure11 kApplicable Customer SegmentProduct / Models & OptionsSegmentJobsApplicationConsumer ElectronicsCircuit Designer, QA, InspectionInverter, Converter, Power conditioner, Industrial ElectronicsAutomotive & componentEnergy (PV

25、inveter)Heavy industryA&DOne click to obtain all key device parameters for power electronics circuit designIV parameters (Ron, BV, Leakage, Vth, Vsat, etc)Capacitance and Gate charge (Ciss, Coss, Crss, Rg, Qg, etc)Power loss calcurationThermal Test (-50 to +250)Up to 3kV / 1500A*) Must be checked af

26、ter CPLWhy-buy B1506A ?Highest valueAll I-V parameters, CV parameters and gate charge in one-boxRon, Vth, Vsat, Breakdown, Leakage, etcCapacitance (Ciss, Crss, Coss, Rg, etc)Gate charge (Qg)Shorten design TATReduce the number of trial circuit development by measuring key device parameters for power

27、lossConduction lossSwitching lossDriving lossEasy-to-useOne click to obtain necessary device parameters on Datasheet characterization modeAutomatic switching between IV and CV, Ciss, Crss and Coss.Thermal test capability from -50 to +250Roadmap of Power Device Analyzer Family2014/052014/062014/07201

28、4/082014/092014/102014/112014/122015/01B1505AEnhanceReleaseCPLShipB1506AReleaseCPLShipB1507AReleaseCPLShipApril 2014SPA246 B1506A New Product Introduction17B1506A IntroductionNew Power Device Analyzer for Circuit DesignEvaluate all power device parameters (I/V/C/Qg/Power loss) in wide operating cond

29、ition (V/I/Temperature) for power circuit design B1507A IntroductionPower Device Capacitance AnalyzerMeasuring all of input, output, reverse capacitance for power devices (FET, IGBT) up to 3kVB1505A enhancement IntroductionB1505A enhancementCapacitance selectorCapacitance fixtureThermal optionGate c

30、hargeB1507A Power Device Capacitance AnalyzerApril 2014SPA246 B1506A New Product Introduction18Introduce onJuly 1st.Evaluate all of Ciss, Coss, Crss, and Rg for power devices under a wide range of operating conditions automaticallyMeasure transistor input, output and reverse transfer capacitances (C

31、iss, Coss, Crss, Cies, Coes, Cres)Measure independent terminal capacitances (Cgs, Cgd, Cds, Cge, Cgc, Cce)Measure capacitances for normally-on devices such as SiC JFET or GaN FETWide operation voltage bias up to +/-3 kVEasy to use and fully automated measurementHow can you measure only Crss?Case 4 :

32、 Need capacitance measurement (1)I have an old curve tracer for checking I-V parameters. Now I have to check the C-V of power device. I tried to measure it with LCR meter but I could not make it. How do I evaluate the capacitance parameters of power devices?How to switch LCR and HVSMU for three term

33、inal device?CMH, CML, AC Guard, DC blocking, AC blocking?MFCMUDevice capacitance selectorHVSMUSwitchAC blocking RDC blocking CAutomatic 3-terminal device capacitance testCMH, CML, AC Guard, DC blocking, AC blocking?How to solve :The new Agilent B1507A High power device capacitance analyzer can help

34、your evaluation.It can measure all of input, output reverse capacitance for FET, IGBT up to 3kV. The instrument can perform all difficult tasks instead of users manual operation.Case 4 : Need capacitance measurement (2)Introduction ActivitiesAprilMayJuneJulyAugustSeptemberOctoberNovemberProduct Mile

35、stoneB1506A IntroductionB1506A CPLB1506A ShipmentSales TrainingFTDHIT-Las VegasHIT-HKFTDAE TrainingATDATDATDS800Event AmericasPower Sources ConferenceECCEEvent EMEAPCIM-EuropeECSCRMEvent JapanIPEC-JapanAMF JapanTechno FrontierEvent AsiaAMF SGAMF MYAMF AUPCIM-ChinaPSECE AMF TWKorea SeminarVIP Tour (T

36、W, CN)April 2014SPA246 B1506A New Product Introduction21Contact Your MDM for the details of regional events.B1506A Success StoryWho?Im an engineering manager of ing inspection working for one of the world biggest consumer electronics company.I am responsibility for inspecting semiconductor devices u

37、sed in my consumer products (camera, TV, PC, etc).His concern?I am inspecting huge amount of devices at various test conditions. I need to make it as easily and automatically as possible. I have many suppliers requesting to verify their devices for our use. It is efficient to verify them if both sup

38、plies and us (device users) can use the same reliable test equipment.His decision?I know Agilent B1505A is the better product but I decided to buy Keithley because of price Lost report from FEIm very busy. Why do I need to visit him? It has been done (lost) deal.Company A is the biggest customer. We

39、d like to keep his attention even we lost the deal. Id like introduce the B1506A for future opportunity.OK, Ill visit him only for 30min.Now evaluating Qg and capacitance is a key to choose the right power device.New B1506A can measure not only traditional I-V but also dynamic parameters like Qg, Cx

40、ss.The datasheet mode allows you to evaluate many parameters. You can fill the datasheet parameters automatically.His Final DecisionThis is what Id like to have. The switching frequency of consumer electronics is now 100kHz and evaluation of Qg is critical. Ill stop buying Keithley and will buy Agil

41、ent B1506A.Positioning : B1505A vs. B1506AB1505AB1506ATarget UserDevice Manufacture and researcherDevice User (Equipment Maker)Target User SegmentPower device researcher, developerProcess engineer in power device manufactureNew material scientist for power deviceCircuit designer of power electronics

42、 circuit ing inspection of power deviceApplication engineer in power semiconductor manufactureUse CaseCharacterize the maximum performance of device operation3kVcheck safe operating area (SOA)Leakage down to sub-pAOn-wafer testMore than 5 terminal devicesResearch for emerging device (GaN Collapse)Ch

43、aracterize power device parameters on datasheet to check the device performanceCharacterize power device parameters under actual operation condition of power electronics circuit. Check device characteristics through wide temperature rangeDevice typePackage deviceOn-wafer devicePackaged deviceUser I/

44、FEasyEXPERTDatasheet characterization modeEasyEXPERTMax. IV1500 A / 10 kV1500 A / 3 kVDifferentiationFlexible configuration (modularity)Ultra-high voltage up to 10kVHigh voltage medium current (HVMCU) for SOAGaN Collapse evaluationLeakage down to sub-pAFixed configurationSelector (switching matrix)

45、for automatic 3-terminal device capacitance measurementGate Charge (Qg) measurementThermal test capabilityAppendix.Target Customer of B1506A (Typical devices & applications)SegmentTyp. DeviceTyp. ApplicationConsumer ElectronicsPower MOS, IGBTDIP-IPMAir-conditioner,Refrigerator,Industrial Electronics

46、IGBT Module, IPMInverter, AC servo,PC/Server powerAutomotive & componentHEV-IPM, HEV-IPUEV/HV motor Energy (PV inverter)IGBT module, IPM, ASIPMPV inverterWindow powerHeavy industryHVIPM, HVIGBT, GCT/GTORailway, construction equipmentA&DPower MOS, IGBT, IGBT module, IPMAirplane,Rader,Appendix.Target

47、Customer of B1506A (Typical company names)SegmentTyp. DeviceTyp. RangeMajor CompaniesConsumer ElectronicsPower MOS, IGBT600V50ASamsung, Phillips, GE, Emerson, Hitachi, Toshiba, Mitsubishi, LG, Siemens, HaierIndustrial ElectronicsIGBT Module, IPM1200V1000ABombardier, Alstom, ABB, Kawasaki Heavy Ind.,

48、 Kobe steel, Daikin, CSR, Schindler, IHI, Mitsubishi Heavy Ind. FANUC, Yaskawa, KUKAAutomotive & componentHEV-IPM, HEV-IPU600V600AGM, Ford, Daimler, BMW, VW, Toyota, Nissan, Honda, Hyundai, Denso, Bosch, Continental, RockwellEnergy (PV inverter)IGBT module, IPM, ASIPMkVA to MVASMA, Power-one, Kaco,

49、Advanced Energy, Fronius, Enphase Energy, Danfoss, Omron, RefuSol, SchneiderHeavy industryHVIPM, HVIGBT, GCT6.5kV6000AYaskawa, Toshiba, Mitsubishi, Hitachi, Fuji Elec, Siemens, Kawasaki, Bombardier, Siemens, AlstomA&DPower MOS, IGBT, IGBT module, IPMSame as industrial electronicsAirbus/EADS, Boeing,

50、 Bombardier, Embraer, Northrop, Lockheed, Raytheon, BAE, United Technologies,B1506A Configuration DetailsAgilent Confidential26B1506A-H21 (20A/3kV)B1506A-H51 (500A/3kV)B1506A-H71 (1500A/3kV)3-pin Inline Package Socket ModuleGate Charge Socket AdapterUpgrade :B1506AU-0151500A Current Option200mm HC c

51、able x 2 200mm normal cable x 8Banana pin adapter x 18Mini alligator clip x 20 Banana pin adapter x 18Mini alligator clip x 20 Large clip x 4Interlock cable x 1DIO cable x 1Thermocouple cableComposite cable x 1B1506AU-T01Thermal Test Enclosure (Thermostream Compatible)OptionBundle accessoriesMain Mo

52、delModule ConfigMPSMU x 1HCSMU x 1HVSMU x 1MCSMU x 2MFCMU x 1Module Config.MPSMU x 1HVSMU x 1MCSMU x 4MFCMU x 1Module Config.MPSMU x 1HVSMU x 1MCSMU x 4MFCMU x 1Upgrade :B1506AU-005500A Current OptionBundle cablesPurchase from partner (inTEST)ThermoStream(need B1506A-T01 option)Thermal Plate (instal

53、led in Fixture)27ThermoStreamModel#:ATS-545 (*)Temperature Range:- 80 +225 Transition Rate:18/sMax Airflow Output:8.5 l/sRemote Interface:GPIB、RS232CDimension:W610D710H1080mmWeight:236 kgAir Supply Pressure:6.3 kg/cm2 7.7 kg/cm2Air Flow Rate Required:7.2 /s 14.3 /sPower Supply:AC220V10%、30A、1Operational Environment:20 28Operational Humidity:0 60%Model#:HP289-PMPlate Dimension:(w/o controller)17cm x 17cm x 3cmController Dimension:25.7cm x 24.6

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權益歸上傳用戶所有。