




版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進行舉報或認領(lǐng)
文檔簡介
Ensurethattheoperatorreadsandunderstandsthedecalsandconsultsthemanualsbeforemaintenanceoroperation.EnsurethattheOperationandMaintenancemanualisnotremovedpermanentlyfromthemachine.Ensurethatmaintenancepersonnelareadequatelytrained,competentandhavereadtheMaintenanceManuals.DATE:MAY2006REV.:CTSC2A-11AOPERATIONANDMAINTENANCEMANUALCONTENTSTSC2A-11APAGECONTENTSPAGE1.0CONTENTS12.0FOREWORD23.0ABBREVIATIONS&SYMBOLS34.0PURCHASEORDERDETAILS45.0SAFETY55.1Safetyinstructions5.2Safetyprecautions5.3Textdecals6.0RECEIPTANDHANDLING86.1Receipt6.2Unpackingandhandling7.0INSTALLATION97.1Locationinplant7.2Dischargeandcondensatepiping7.3Electrical7.4Outdoorshelteredinstallation8.0GENERALINFORMATION128.1Technicalinformation8.2Electricalschematics8.3Generaldescription9.0OPERATINGINSTRUCTIONS259.1Basicoperation9.2Controlpanel9.3Displayscreen9.4Alarms10.0STARTUPPROCEDURE2610.1Initialstartup11.0MAINTENANCE2711.1Maintenance11.2Maintenanceprocedures11.3Routinemaintenance12.0FAULTFINDING3012.1Generalfaults2.0FOREWORDThecontentsofthismanualareconsideredtobeproprietaryandconfidentialtoIngersollRandandshouldnotbereproducedwithoutthepriorwrittenpermissionofIngersollRand.Nothingcontainedinthisdocumentisintendedtoextendanypromise,warrantyorrepresentation,expressedorimplied,regardingtheIngersollRandproductsdescribedherein.Anysuchwarrantiesorothertermsandconditionsofsaleofproductsshallbeinaccordancewiththestandardtermsandconditionsofsaleforsuchproducts,whichareavailableuponrequest.Thismanualcontainsinstructionsandtechnicaldatatocoverallroutineoperationandscheduledmaintenancetasksbyoperationandmaintenancestaff.MajoroverhaulsareoutsidethescopeofthismanualandshouldbereferredtoanauthorizedIngersollRandservicedepartment.Allcomponents,accessories,pipesandconnectorsaddedtothecompressedairsystemshouldbe:?ofgoodquality,procuredfromareputablemanufacturerand,whereverpossible,beofatypeapprovedbyIngersollRand.?clearlyratedforapressureatleastequaltothemachinemaximumallowableworkingpressure.?compatiblewiththecompressorlubricant/coolant.?accompaniedwithinstructionsforsafeinstallation,operationandmaintenance.IngersollRandreservestherighttomakechangesandimprovementstoproductswithoutnoticeandwithoutincurringanyobligationtomakesuchchangesoraddsuchimprovementstoproductssoldpreviously.DetailsofapprovedequipmentareavailablefromIngersollRandServicedepartments.Thismachinehasbeendesignedandsuppliedforuseonlyinthefollowingspecifiedconditionsandapplications:?Dryingwatervaporoutofcompressedaircontainingnoknownordetectableadditionalgases,vaporsorparticles?OperationwithintheambienttemperaturerangespecifiedintheGENERALINFORMATIONsectionofthismanual.IFINDOUBTCONSULTSUPERVISION.ThecompanyacceptsnoresponsibilityforerrorsintranslationofthismanualfromtheoriginalEnglishversion.SSRULTRACOOLANTisaregisteredtrademarkofIngersoll-RandCompanyUSA.?COPYRIGHT2006INGERSOLL-RANDCOMPANYWARNINGTheuseofthemachineinanyofthesituationtypeslistedintable1:-aIsnotapprovedbyIngersollRand,bMayimpairthesafetyofusersandotherpersons,andcMayprejudiceanyclaimsmadeagainstIngersollRand.TABLE1WARNING-NOTPERMITTEDUseofthemachinetoconditioncompressedairfor:adirecthumanconsumptionbindirecthumanconsumption.UseofthemachineoutsidetheambienttemperaturerangespecifiedintheGENERALINFORMATIONSECTIONofthismanual.Useofthemachinewherethereisanyactualorforeseeableriskofhazardouslevelsofflammablegasesorvapors.THISMACHINEISNOTINTENDEDANDMUSTNOTBEUSEDINPOTENTIALLYEXPLOSIVEATMOSPHERES,INCLUDINGSITUATIONSWHEREFLAMMABLEGASESORVAPOURSMAYBEPRESENT.UseofthemachinefittedwithnonIngersollRandapprovedcomponents.Useofthemachinewithsafetyorcontrolcomponentsmissingordisabled.Connectiontoanelectricalsupplyofincorrectvoltageand/orfrequency.WARNINGTheuseofrepairpartsotherthanthoseincludedwithintheIngersollRandapprovedpartslistmaycreatehazardousconditionsoverwhichIngersollRandhasnocontrol.ThereforeIngersollRandcannotbeheldresponsibleforequipmentinwhichnon-approvedrepairpartsareinstalled.WARNINGThedryercancontainpressurizedairintheshutdownmode.AnypressurizedairmustberelievedfromthecompressorairsystempriortobreachingthedryercompressedairsideNOTICEThemanualisintendedforworldwideuseandcontainsbothmetricandimperialdatawhererequired.3.0ABBREVIATIONS&SYMBOLSTSC2A-11AContactIngersollRandforserialnumber->####UptoSerialNo.####->FromSerialNo.*Notillustrated?OptionNRNotrequiredARAsrequiredSMSitemaster/SitepackHAHighambientmachineWCWatercooledmachineACAircooledmachineERSOpendripproof(motorppmpartspermillionenEnglishzhChinese4.0PURCHASEORDERDETAILSREFRIGERATEDDRYERThisunitwaspurchasedfrom___________________________________________________________________________________________________________________________Ingersoll-RandCompanyreservestherighttomakechangesoraddimprovementswithoutnoticeandwithoutincurringanyobligationtomakesuchchangesoraddsuchimprovementstoproductssoldpreviously.No.ofunitsonorder:_________________________CustomerOrderNo:_________________________Ingersoll-RandCo.OrderNo.:__________________Forreadyreference:Recordtheserialnumberandmodelnumberofyourunithere.SerialNumber:_____________________________ModelNumber:_____________________________4TSC2A-11ASafetyinstructionsintheoperatorsmanualarebold-facedforemphasis.ThesignalwordsDANGER,WARNINGandCAUTIONareusedtoindicatehazardseriousnesslevelsasfollows.Ensurethattheoperatorreadsandunderstandsthedecalsandconsultsthemanualsbeforemaintenanceoroperation.EnsurethattheOperationandMaintenancemanual,andthemanualholder,arenotpermanentlyremovedfromthemachine.Ensurethatmaintenancepersonnelareadequatelytrained,competentandhavereadtheMaintenanceManuals.GeneralInformationCompressedrefrigerantandelectricitycanbedangerous.Beforeundertakinganyworkonthedryer,ensurethattheelectricalsupplyhasbeenisolated,lockedoff,taggedandthedryerhasbeenrelievedofallpressure.Makesurethatallprotectivecoversareinplaceandthatthecanopy/doorsareclosedduringoperation.InstallationofthisdryermustbeinaccordancewithrecognizedelectricalcodesandanylocalHealthandSafetyCodes.Useonlysafetysolventforcleaningthedryerandauxiliaryequipment.CompressedairEnsurethatthemachineisoperatingattheratedpressureandthattheratedpressureisknowntoallrelevantpersonnel.Allairpressureequipmentinstalledinorconnectedtothemachinemusthavesafeworkingpressureratingsofatleastthemachineratedpressure.Ifmorethanonedryerisconnectedtoonecommondownstreamplant,effectivecheckvalvesandisolationvalvesmustbefittedandcontrolledbyworkprocedures,sothatonemachinecannotaccidentallybepressurized/overpressurizedbyanother.Ifasafetyvalveisinstalledbetweentheisolationvalveandthedryer,itmusthavesufficientcapacitytorelievethefullcapacityofthecompressor(s.Ifthedischargedairistobeultimatelyreleasedintoaconfinedspace,adequateventilationmustbeprovided.Theuseofplasticbowlsonlinefilterswithoutmetalguardscanbehazardous.Theirsafetycanbeaffectedbyeithersyntheticlubricants,ortheadditivesusedinmineraloils.Metalbowlsshouldbeusedonapressurizedsystem.Whenusingcompressedair,alwaysuseappropriatepersonalprotectiveequipment.Allpressurecontainingparts,especiallyflexiblehosesandtheircouplings,mustberegularlyinspected,befreefromdefectsandbereplacedaccordingtotheManualinstructions.Compressedaircanbedangerousifincorrectlyhandled.Beforedoinganyworkontheunit,ensurethatallpressureisventedfromthesystemandthatthemachinecannotbestartedaccidentally.Avoidbodilycontactwithcompressedair.RefrigerantRefrigerationpipescanbeveryhotorverycolddependingontheoperatingpressureandmediaphase.Avoidcontactwiththesecomponents.Onlytechnicianstrainedonservicingrefrigerationcircuitsmayworkonrefrigerationsystems.Handling,recovery,anddispensingrefrigerantrequiresspecificLocalandNationalrefrigerantcertifications.MaterialsThefollowingsubstancesareusedinthemanufactureofthismachineandmaybehazardoustohealthifusedincorrectly:?refrigerant?compressoroilForfurtherinformation,requestandconsulttheRefrigerantandOilMaterialDataSheets.Thesheetsaredesignatedas80441231refrigerantMSDS,80441926refrigerantoilMSDSandcanbeobtainedfromyourlocalIRoffice,DistributororAirCenter.Consultaphysicianiftherefrigerantisinhaledortherefrigerantoilisingested.TransportWhenloadingortransportingmachinesensurethatthespecifiedliftingandtiedownpointsareused.Itisrecommendedthatthemachinebemovedusingtheforkliftslotsinthemachinebase.Refertosection8forreferenceinformation.5.1SAFETYINSTRUCTIONSDANGERIndicatesthepresenceofahazardwhichWILLcauseseriousinjury,deathorpropertydamage,ifignored.WARNINGIndicatesthepresenceofahazardwhichCANcauseseriousinjury,deathorpropertydamage,ifignored.CAUTIONIndicatesthepresenceofahazardwhichWILLorcancauseinjuryorpropertydamage,ifignored.NOTICEIndicatesimportantset-up,operatingormaintenanceinformation.5.2SAFETYPRECAUTIONSDANGERBREATHINGREFRIGERANTCANCAUSEDEATHBYSUFFOCATION.DONOTBREATHEFUMES.WARNINGAVOIDINGESTION,SKINCONTACTANDINHALATIONOFFUMESElectricalThedryerhashighanddangerousvoltageinthemotorstarterandcontrolbox.Allinstallationsmustbeinaccordancewithrecognizedelectricalcodes.Beforeworkingontheelectricalsystem,besuretoremovevoltagefromthesystembyusingamanualdisconnectswitch.Acircuitbreakerorfusesafetyswitchmustbeprovidedintheelectricalsupplylineleadingtothedryer.Thoseresponsibleforinstallationofthisequipmentmustprovidesuitablegrounds,maintenanceclearanceandlightningarrestorsforallelectricalcomponentsinaccordancewithNationalandLocalcoderequirements.Keepallpartsofthebodyandanyhand-heldtoolsorotherconductiveobjects,awayfromexposedlivepartsofthedryerelectricalsystem.Maintaindryfooting,standoninsulatingsurfacesanddonotcontactanyotherportionofthedryerwhenmakingadjustmentsorrepairstoexposedlivepartsofthedryerelectricalsystem.Closeallaccessdoorswhenthedryerisleftunattended.DonotuseextinguishersintendedforClassAorClassBfiresonelectricalfires.UseonlyextinguisherssuitableforclassBCorclassABCfires.Attemptrepairsonlyinclean,dry,welllightedandventilatedareas.Connectthedryeronlytoelectricalsystemsthatarecompatiblewithitselectricalcharacteristicsandthatarewithinit’sratedcapacity.CondensatedisposalCondensatecannotbedischargedintofresh/surfacewaterdrains.InsomeregionscompressorcondensatecontainingULTRACOOLANTcanbefeddirectlyintoadrainagesystemthathasdownstreamsewagetreatment.Aswastewaterregulationsvarybycountryandregionitistheresponsibilityoftheusertoestablishthelimitationsandregulationsintheirparticulararea.IngersollRandanditsassociateddistributorsarehappytoadviseandassistinthesematters.RefrigerantOilStepstobetakeninthecaseofspillage:Soakupwithasuitableabsorbentmaterial,thensweepintoaplasticbagfordisposal.Burninanapprovedincinerator,oraccordingtolocalareaorcountryregulations.Forfurtherinformation,consultMaterialSafetyDataSheets.WARNINGThereisahightemperatureshutdownfeaturebuiltintoeachdryer.Refertomaintenancesectionforservice.Failuretoadheretotheserecommendationscanresultinmechanicalfailure,propertydamageandseriousinjuryordeath.?Allairandwaterinlet,andairandwaterdischargepipeworktoandfromtheinletanddischargeportconnectionsmusttakeintoaccountvibration,pulsations,temperature,maximumpressureapplied,corrosionandchemicalresistance.Inaddition,itshouldbenotedthatlubricatedcompressorswilldischargesomeoilintotheairstream;therefore,compatibilitybetweendischargepiping,systemaccessoriesandsoftwaremustbeassured.?Fortheforegoingreasons,theuseofplasticpiping,solderedcopperfittingsandrubberhoseasairpipingisnotrecommended.Inaddition,flexiblejointsand/orflexlinescanonlybeconsideredforsuchpurposesiftheirspecificationsfittheoperatingparametersofthesystem.?Itistheresponsibilityoftheinstallerandownertoprovidetheappropriateservicepipeworktoandfromthemachine.WARNING“IngersollRandairdryersarenotdesigned,intended,orapprovedforbreathingairapplications.IngersollRanddoesnotapprovespecializedequipmentforbreathingairapplicationandassumesnoresponsibilityorliabilityfordryersusedforbreathingairservices.”WARNINGThespecificationofthismachineissuchthatthemachineisnotsuitableforuseinflammablegasriskareas.WARNINGVentcompressedairsystembeforeopening.6TSC2A-11AReadandunderstandsafetyandinformationdecalsthoroughly.Heedwarningsandfollowinstructions.Ifyoudonotunderstand,informyoursupervisor.5.3DECALSReadtheOperationandMaintenancemanualbeforeoperationormaintenanceofthismachineisundertaken.Liftingpoint.WARNING-Hotsurface.WARNING:Electricalshockrisk.ROTATIONDonotoperatethemachinewithouttheguardbeingfitted.CONDENSATEDRAINPOWERINLET(ACWARNING-Donotundertakeanymaintenanceonthismachineuntiltheelectricalsupplyisdisconnectedandtheairpressureistotallyrelieved.6.0RECEIPT/HANDLING6.1RECEIPTWhenyoureceivethedryerpleaseinspectitclosely.Anyindicationofcarelesshandlingbythecarriershouldbenotedonthedeliveryreceiptespeciallyifthedryerwillnotbeimmediatelyunpacked.Obtainingthedeliverypersonssignedagreementtoanynoteddamageswillfacilitateanyfutureinsuranceclaims.IMPORTANTREADTHISLOSTORDAMAGEDGOODSTHOROUGHLYINSPECTTHISSHIPMENTIMMEDIATELYUPONARRIVALOURRESPONSIBILITYFORTHISSHIPMENTCEASEDWHENTHECARRIERSIGNEDBILLOFLADINGIfgoodsarereceivedshortorindamagedcondition,itisimportantthatyounotifythecarrierandinsistonanotationofthelossordamageacrossthefaceofthefreightbill.Otherwisenoclaimcanbeenforcedagainstthetransportationcompany.Ifconcealedlossordamageisdiscovered,notifyyourcarrieratonceandrequestaninspection.Thisisabsolutelynecessary.Unlessyoudothisthecarrierwillnotentertainanyclaimforlossordamage.Theagentwillmakeaninspectionandgrantaconcealeddamagenotation.Ifyougivethetransportationcompanyaclearreceiptforgoodsthathavebeendamagedorlostintransit,youdosoatyourownriskandexpense.WE,ATlR,AREWILLINGTOASSISTYOUINEVERYPOSSIBLEMANNERTOCOLLECTCLAIMSFORLOSSORDAMAGE,BUTTHEWILLINGNESSONOURPARTDOESNOTMAKEUSRESPONSIBLEFORCOLLECTIONOFCLAIMSORREPLACEMENTOFMATERIAL.THEACTUALFILINGANDPROCESSINGOFTHECLAIMISYOURRESPONSIBILITY.Ingersoll-RandCompany6.2UNPACKINGANDHANDLINGThedryerwillnormallybedeliveredwithacardboardboxorothercover.Ifaknifehastobeusedtoremovethiscover,ensurethattheexteriorpaintworkofthedryerisnotdamaged.Incorporatedwithinthebaseofthedryerareslotstoenableaforklifttrucktomovethemachine.Ensuretruckforksarefullyengagedonbothsides.Alternativelyaspecialliftingframecanbeutilizedtoenableacraneorhoisttomovethedryer.Useonlymarkedliftingpoints.8TSC2A-11AFortechnicalinformationseesection8.0.Ensurethatthecorrecttiedownpointsareused.Ambienttemperatureshigherthan46°C(115°Fmustbeavoidedaswellasareasofhighhumidity.Consideralsotheenvironmentsurroundingornearthedryer.Theareaselectedforthelocationofthedryershouldbefreeofdust,chemicals,metalfilings,paintfumesandoverspray.Hardsurfacesmayreflectnoisewithanapparentincreaseinthedecibellevel.Whensoundtransmissionisimportant,asheetofrubberorcorkcanbeinstalledbeneaththemachinetoreducenoise.Flexiblepipingmayberequired.Itisrecommendedthatprovisionbemadeforliftingheavycomponentsduringmajoroverhaul.Useonlyliftingpointsprovided.MinimumspaceinfrontofcontrolpaneldoorasrequiredbyNationalorLocalcodesmustbemaintained.Thedryercanbeinstalledonanylevelfloorcapableofsupportingit.Adry,wellventilatedareawheretheatmosphereisascleanaspossibleisrecommended.Sufficientspaceallaroundandabovethedryermustbeallowed,toenabletheeffectiveremovalofthecoolingairwhich,inturn,willreducetheriskofrecirculatingthecoolingairbackthroughthedryer.7.1LOCATIONINPLANTKEY1.Compressor2.AirReceiver3.AirDryer4.Compressedairfilters5.Systemdemandpoints6.Valve,vent7.Valve,isolation8.Valve,condensate9.Valve,bypassCAUTIONAminimumof1m(3ftallroundthedryerisrecommended.Ifheadroomisrestricted,thentheexhaustshouldbeductedordeflectedawayfromthemachine.10TSC2A-11AItisessentialwheninstallinganewdryer[3],toreviewthetotalairsystem.Thisistoensureasafeandeffectivetotalsystem.Oneitemwhichshouldbeconsideredisliquidcarryover.Installationofairdryers[3]isalwaysgoodpracticesinceproperlyselectedandinstalledtheycanreduceanyliquidcarryovertozero.Pipingshouldbeatleastaslargeastheconnectionoftheequipment.Allpipingandfittingsshouldbesuitablyratedfortheoperatingpressure.Itisgoodpracticetolocateby-passpipingclosetothedryerandtoinstalllinefilters[4].IMPORTANT:Thedrainlinemustslopedownwardfromthebasetoworkproperly.Thedryershouldbeproperlygrounded/earthedinaccordancewithLocalandNationalCoderequirements.InstallationofthisdryermustbeinaccordancewithrecognizedelectricalcodesandanylocalHealthandSafetyCodes.Thedryermusthaveitsownisolatorsituatedadjacenttoit.Thefuseprotectingthecircuitandthedryermustbeselectedinaccordancewithlocalandnationalcoderequirementsonthebasisofthedataprovidedinthegeneralinformationsection.Feedercablesshouldbesizedbythecustomer/electricalcontractortoensurethatthecircuitisbalancedandnotoverloadedbyotherelectricalequipment.Thelengthofwiringfromasuitableelectricalfeedpointiscriticalasvoltagedropsmayimpairtheperformanceofthedryer.FeedercableconnectionstoincomingterminalsL1-L2-L3shouldbetightandclean.Theappliedvoltagemustbecompatiblewiththedataplateratings.Aholeisprovidedforincomingpowerconnection.Ifitisnecessarytomakeaholeinthecontrolboxinadifferentlocation,careshouldbetakentonotallowmetalshavingstoenterthestarterandotherelectricalcomponentswithinthebox.Ifanotherholeisused,theoriginalholemustbeblockedoff.Thefeedercablemustbesuitablyglandedintotheelectricalboxtoensurethatdirtyairdoesnotby-pass.Oncompletionofelectricalinstallation,checkthatfanmotorrotationiscorrect.Coolingairmustdischargeupwards.7.2DISCHARGEANDCONDENSATEPIPINGKEY1.Compressor2.AirReceiver3.AirDryer4.Compressedairfilters5.Systemdemandpoints6.Valve,vent7.Valve,isolation8.Valve,condensate9.Valve,bypassCAUTIONTheuseofplasticbowlsonlinefiltersandotherplasticairlinecomponentswithoutmetalguardscanbehazardous.Theirsafetycanbeaffectedbyeithersyntheticcoolantsortheadditivesusedinmineraloils.Fromasafetystandpoint,metalbowlsshouldbeusedonanypressurizedsystem.NOTICEDonotusethedryertosupportthepiping.7.3ELECTRICALCAUTIONThisprocedureshouldonlybecarriedoutbyaqualifiedelectrician,electricalcontractororyourlocalIngersollRandDistributororAirCenter.NOTICEThecontrolcircuittransformerhasdifferentvoltagetappings.Ensurethatthesearesetforthespecificappliedvoltagepriortostarting.TSCdryersarenotsuitableforoutdoorinstallation.InstallingaTSCdryeroutsidevoidsthewarrantyofthedryer.7.4OUTDOORSHELTEREDINSTALLATION7.5MULTIPLECOMPRESSOR/DRYERINSTALLATIONSKEYA/CAirCompressorDAirDryerCAUTIONContactIngersollRandforproperdesignandapplication.Failuretodosomayresultinoverloadingofthedryer(s,dryer(sshutdown,andwaterinthecompressedairsystem.12TSC2A-11A(1Alwaysapplylocalelectricalcodesforsizingcablesandfusing.Onabsenceoflocalcodes,theminimumcablesizeshouldalwaysbecalculatedonbasisofmaximumpackagefullloadx1.25.(2Highpressureoptionsallowmachinestooperateathighpressureratings.Seemachinespecificationdatadecalforpressureratingsforthesemachines.(3Thelowsiderefrigerantpressureisfactorysetat5.38-5.66barg(78-82psig.Itmayneedtobeadjustedatthehotgasvalveperiodicallyduetolocalambientandseasonalchangestoavoiddryerfreeze-up.Seesection“RoutineMaintenance"fortheadjustmentprocedure.8.1TECHNICALINFORMATIONCOMMONTECHNICALDATAGeneralMaximumambienttemperature°C(°F46(115Minimumambienttemperature°C(°F2(35RefrigeranttypeR404ARefrigerantoilISO32Polyolester(POEMaximumstandardcompressedairinletpressure,barg(psig(210.45(150ControlsettingsHotgasvalvesetting,barg(psig(35.38-5.93(78-86Thermalexpansionvalvesuperheat,°C(°F3.3-5.0(6.0-9.0Highrefrigeranttemperatureswitchsetting°C(°F115(240Highpressureswitchsettingbarg(psig29.3(425Fanpressureswitchsettingon/off(barg/psig16.5/13.1(240/190Fantempswitchsettingon/off°C(°F99/82(210/180Lowpressureswitchsettingbarg(psig2.8(40AirCoolingSystemMaximum?Pacrossductwork,mmH2O(in.H2O1.0(0.04KEYA.ElectricalconduitconnectionB.Compressedairinlet50Hz-2"BSPTfemaleC.Compressedairdischarge50Hz-2”BSPTfemaleD.Condensatedrain50Hz-1/8”BSPTfemaleNOTES:1.Weight(approximate:207KG(455LBS2.Refrigerant:R-404A3.Toleranceondimensions:±13mm(0.5”unlessotherwisestated.4.305mm(12"minimumelectricalcablelengthallowanceisrequiredbetweentheelectricalcableentry(Aandthemainsterminalblock.5.Recommendedclearanceonallsides1m(3ftfrontpanelwithstarterdoormayrequiremoreasdefinedbylocalandnationalelectricalcodes.6.Externalpipingshallnotexertanyunresolvedmomentsorforcesonit.7.Thereshouldbenoplasticpiping,notapprovedbyIR,attachedtothisunitorusedforanylinesdownstream.8.Fieldinstalledductingtoandfromthedryercannotaddmorethan1.0mm(0.04waterairresistance.8.2INSTALLATIONDRAWINGTSC-2A&TSC-3A14TSC2A-11AKEYA.ElectricalconduitconnectionB.Compressedairinlet50Hz-2”BSPTfemaleC.Compressedairdischarge50Hz-2”BSPTfemaleD.Condensatedrain50Hz-1/4”BSPTNOTES:1.Weight(approximate:TSC-4A&TSC-5A:226kg(497lb.TSC-6A:230kg(506lb.TSC-7A:230kg(506lb.2.Refrigerant:R-404A3.Toleranceondimensions:±13mm(0.5”unlessotherwisestated.4.305mm(12"minimumelectricalcablelengthallowanceisrequiredbetweentheelectricalcableentry(Aandthemainsterminalblock.5.Recommendedclearanceonallsides1m(3ftfrontpanelwithstarterdoormayrequiremoreasdefinedbylocalandnationalelectricalcodes.6.Externalpipingshallnotexertanyunresolvedmomentsorforcesonit.7.Thereshouldbenoplasticpiping,notapprovedbyIR,attachedtothisunitorusedforanylinesdownstream.8.Fieldinstalledductingtoandfromthedryercannotaddmorethan1.0mm(0.04waterairresistance.TSC-4A,TSC-5A,TSC-6A&TSC-7AModelDimension”X"TSC-4A&TSC-5A1408mmTSC-6A1396mmTSC-7A1410mmKEYA.ElectricalconduitconnectionB.Compressedairinlet50Hz:3"BSPfemaleC.Compressedairdischarge50Hz:3"BSPfemaleD.Condensatedrain50Hz:1/4"BSPfemaleNOTES:1.Weight(approximate:TSC-8A:429KG(944LBS2.Refrigerant:R-404A3.Toleranceondimensions:±13mm(0.5unlessotherwisestated.4.305mm(12"minimumelectricalcablelengthallowanceisstarterdoormayrequiremoreasdefinedbylocalandnationalelectricalcodes.6.Externalpipingshallnotexertanyunresolvedmomentsorforcesonit.7.Thereshouldbenoplasticpiping,notapprovedbyIR,attachedtothisunitorusedforanylinesdownstream.8.Fieldinstalledductingtoandfromthedryercannotaddmorethan1.0mm(0.04waterairresistance.16TSC2A-11AKEYA.ElectricalconduitconnectionB.Compressedairinlet50Hz:3"BSPfemaleC.Compressedairdischarge50Hz:3"BSPfemaleD.Condensatedrain50Hz:1/4"BSPfemaleNOTES:1.Weight(approximateTSC-9A:429KG(944LBS2.Refrigerant:R-404A3.Toleranceondimensions:±13mm(0.5unlessotherwisestated.4.305mm(12"minimumelectricalcablelengthallowanceisrequiredbetweentheelectricalcableentry(Aandthemainsterminalblock.5.Recommendedclearanceonallsides1m(3ftfrontpanelwithstarterdoormayrequiremoreasdefinedbylocalandnationalelectricalcodes.6.Externalpipingshallnotexertanyunresolvedmomentsorforcesonit.7.Thereshouldbenoplasticpiping,notapprovedbyIR,attachedtothisunitorusedforanylinesdownstream.8.Fieldinstalledductingtoandfromthedryercannotaddmorethan1.0mm(0.04waterairresistance.KEYA.ElectricalconduitconnectionB.Compressedairinlet50Hz:4"PN16-DNC.Compressedairdischarge50Hz:4"PN16-DND.Condensatedrain50Hz:1/4"BSPfemaleNOTES:1.Weight(approximate:TSC-10A:490KG(1078LBS2.Refrigerant:R-404A3.Toleranceondimensions:±13mm(0.5”unlessotherwisestated.4.305mm(12"minimumelectricalcablelengthallowanceisstarterdoormayrequiremoreasdefinedbylocalandnationalelectricalcodes.6.Externalpipingshallnotexertanyunresolvedmomentsorforcesonit.7.Thereshouldbenoplasticpiping,notapprovedbyIR,attachedtothisunitorusedforanylinesdownstream.8.Fieldinstalledductingtoandfromthedryercannotaddmorethan1.0mm(0.04waterairresistance.KEYA.ElectricalconduitconnectionB.Compressedairinlet50Hz:4"PN16-DNC.Compressedairdischarge50Hz:4"PN16-DND.Condensatedrain50Hz:1/4"BSPfemaleNOTES:1.Weight(app
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負責。
- 6. 下載文件中如有侵權(quán)或不適當內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 設(shè)施維護合同履約金協(xié)議
- 羽絨制品企業(yè)質(zhì)量管理與質(zhì)量保證體系考核試卷
- 糖批發(fā)企業(yè)市場預測與決策支持考核試卷
- 電力設(shè)備的智能運維與維修考核試卷
- 房屋坍塌安全避險與自救指南
- 環(huán)境監(jiān)測與生態(tài)紅線管理考核試卷
- 彈射玩具行業(yè)生產(chǎn)調(diào)度與制造執(zhí)行系統(tǒng)考核試卷
- 電機制造工藝裝備升級方案考核試卷
- 空調(diào)器自動清潔技術(shù)考核試卷
- 陽光自信心理安全教育
- 南京師范大學自主招生個人陳述范文與撰寫要點
- 鐵粉運輸合同協(xié)議
- 計算機網(wǎng)絡(luò)安全知識試題及答案2025年計算機二級考試
- 廣州廣州市天河區(qū)華陽小學-畢業(yè)在即家校共話未來-六下期中家長會【課件】
- 第4單元 亮火蟲(教學設(shè)計)-2024-2025學年粵教花城版(2024)音樂一年級下冊
- 車間生產(chǎn)材料管理制度
- 公司事故隱患內(nèi)部報告獎勵制度
- 大學生創(chuàng)新創(chuàng)業(yè)基礎(chǔ)(創(chuàng)新創(chuàng)業(yè)課程)完整全套教學課件
- 美國數(shù)學競賽AMC8講座課件
- 2020年國家義務(wù)教育質(zhì)量測查德育科目模塊一模擬試題含參考答案
- 導管固定-PPT課件
評論
0/150
提交評論