

下載本文檔
版權說明:本文檔由用戶提供并上傳,收益歸屬內容提供方,若內容存在侵權,請進行舉報或認領
文檔簡介
IntroductionIonisingradiationmaybeusedduringthemanufacturingprocessforvariouspurposesincludingthereductionofbioburdenandthesterilisationofstartingmaterials,packagingcomponentsorproductsandthetreatmentofbloodproducts.Therearetwotypesofirradiationprocess:GammaIrradiationfromaradioactivesourceandhighenergyElectronIrradiation(Betaradiation)fromanaccelerator.GammaIrradiation:twodifferentprocessingmodesmaybeemployed:Batchmode:theproductisarrangedatfixedlocationsaroundtheradiationsourceandcannotbeloadedorunloadedwhiletheradiationsourceisexposed.Continuousmode:anautomaticsystemconveystheproductsintotheradiationcell,pasttheexposedradiationsourcealongadefinedpathandatanappropriatespeed,andoutofthecell.ElectronIrradiation:theproductisconveyedpastacontinuousorpulsedbeamofhighenergyelectrons(Betaradiation)whichisscannedbackandforthacrosstheproductpathway.ResponsibilitiesTreatmentbyirradiationmaybecarriedoutbythepharmaceuticalmanufacturerorbyanoperatorofaradiationfacilityundercontract(a“contractmanufacturer”),bothofwhommustholdanappropriatemanufacturingauthorisation.Thepharmaceuticalmanufacturerbearsresponsibilityforthequalityoftheproductincludingtheattainmentoftheobjectiveofirradiation.Thecontractoperatoroftheradiationfacilitybearsresponsibilityforensuringthatthedoseofradiationrequiredbythemanufacturerisdeliveredtotheirradiationcontainer(i.e.theoutermostcontainerinwhichtheproductsareirradiated).Therequireddoseincludingjustifiedlimitswillbestatedinthemarketingauthorisationfortheproduct.DosimetryDosimetryisdefinedasthemeasurementoftheabsorbeddosebytheuseofdosimeters.Bothunderstandingandcorrectuseofthetechniqueisessentialforthevalidation,commissioningandcontroloftheprocess.Thecalibrationofeachbatchofroutinedosimetersshouldbetraceabletoanationalorinternationalstandard.Theperiodofvalidityofthecalibrationshouldbestated,justifiedandadheredto.Thesameinstrumentshouldnormallybeusedtoestablishthecalibrationcurveoftheroutinedosimetersandtomeasurethechangeintheirabsorbanceafterirradiation.Ifadifferentinstrumentisused,theabsoluteabsorbanceofeachinstrumentshouldbeestablished.Dependingonthetypeofdosimeterused,dueaccountshouldbetakenofpossiblecausesofinaccuracyincludingthechangeinmoisturecontent,changeintemperature,timeelapsedbetweenirradiationandmeasurement,andthedoserate.Thewavelengthoftheinstrumentusedtomeasurethechangeinabsorbanceofdosimetersandtheinstrumentusedtomeasuretheirthicknessshouldbesubjecttoregularchecksofcalibrationatintervalsestablishedonthebasisofstability,purposeandusage.ValidationoftheprocessValidationistheactionofprovingthattheprocess,i.e.thedeliveryoftheintendedabsorbeddosetotheproduct,willachievetheexpectedresults.Therequirementsforvalidationaregivenmorefullyinthenoteforguidanceon“theuseofionisingradiationinthemanufactureofmedicinalproducts”.Validationshouldincludedosemappingtoestablishthedistributionofabsorbeddosewithintheirradiationcontainerwhenpackedwithproductinadefinedconfiguration.Anirradiationprocessspecificationshouldincludeatleastthefollowing:detailsofthepackagingoftheproduct;theloadingpattern(s)ofproductwithintheirradiationcontainer.Particularcareneedstobetaken,whenamixtureofproductsisallowedintheirradiationcontainer,thatthereisnounderdosingofdenseproductorshadowingofotherproductsbydenseproduct.Eachmixedproductarrangementmustbespecifiedandvalidated;theloadingpatternofirradiationcontainersaroundthesource(batchmode)orthepathwaythroughthecell(continuousmode);maximumandminimumlimitsofabsorbeddosetotheproduct[andassociatedroutinedosimetry];maximumandminimumlimitsofabsorbeddosetotheirradiationcontainerandassociatedroutinedosimetrytomonitorthisabsorbeddose;otherprocessparameters,includingdoserate,maximumtimeofexposure,numberofexposures,etc.Whenirradiationissuppliedundercontractatleastparts(d)and(e)oftheirradiationprocessspecificationshouldformpartofthatcontract.CommissioningoftheplantGeneralCommissioningistheexerciseofobtaininganddocumentingevidencethattheirradiationplantwillperformconsistentlywithinpredeterminedlimitswhenoperatedaccordingtotheprocessspecification.Inthecontextofthisannex,predeterminedlimitsarethemaximumandminimumdosesdesignedtobeabsorbedbytheirradiationcontainer.Itmustnotbepossibleforvariationstooccurintheoperationoftheplantwhichgiveadosetothecontaineroutsidetheselimitswithouttheknowledgeoftheoperator.Commissioningshouldincludethefollowingelements:Design;Dosemapping;Documentation;Requirementforre-commissioning.GammairradiatorsDesignTheabsorbeddosereceivedbyaparticularpartofanirradiationcontaineratanyspecificpointintheirradiatordependsprimarilyonthefollowingfactors:theactivityandgeometryofthesource;thedistancefromsourcetocontainer;Thedurationofirradiationcontrolledbythetimersettingorconveyorspeed;Thecompositionanddensityofmaterial,includingotherproducts,betweenthesourceandtheparticularpartofthecontainer.Thetotalabsorbeddosewillinadditiondependonthepathofcontainersthroughacontinuousirradiatorortheloadingpatterninabatchirradiator,andonthenumberofexposurecycles.Foracontinuousirradiatorwithafixedpathorabatchirradiatorwithafixedloadingpattern,andwithagivensourcestrengthandtypeofproduct,thekeyplantparametercontrolledbytheoperatorisconveyorspeedortimersetting.DoseMappingForthedosemappingprocedure,theirradiatorshouldbefilledwithirradiationcontainerspackedwithdummyproductsorarepresentativeproductofuniformdensity.Dosimetersshouldbeplacedthroughoutaminimumofthreeloadedirradiationcontainerswhicharepassedthroughtheirradiator,surroundedbysimilarcontainersordummyproducts.Iftheproductisnotuniformlypacked,dosimetersshouldbeplacedinalargernumberofcontainers.Thepositioningofdosimeterswilldependonthesizeoftheirradiationcontainer.Forexample,forcontainersupto1x1x0.5m,athree-dimensional20cmgridthroughoutthecontainerincludingtheoutsidesurfacesmightbesuitable.Iftheexpectedpositionsoftheminimumandmaximumdoseareknownfromapreviousirradiatorperformancecharacterisation,somedosimeterscouldberemovedfromregionsofaveragedoseandreplacedtoforma10cmgridintheregionsofextremedose.Theresultsofthisprocedurewillgiveminimumandmaximumabsorbeddosesintheproductandonthecontainersurfaceforagivensetofplantparameters,productdensityandloadingpattern.Ideally,referencedosimetersshouldbeusedforthedosemappingexercisebecauseoftheirgreaterprecision.Routinedosimetersarepermissiblebutitisadvisabletoplacereferencedosimetersbesidethemattheexpectedpositionsofminimumandmaximumdoseandattheroutinemonitoringpositionineachofthereplicateirradiationcontainers.Theobservedvaluesofdosewillhaveanassociatedrandomuncertaintywhichcanbeestimatedfromthevariationsinreplicatemeasurements.Theminimumobserveddose,asmeasuredbytheroutinedosimeters,necessarytoensurethatallirradiationcontainersreceivetheminimumrequireddosewillbesetintheknowledgeoftherandomvariabilityoftheroutinedosimetersused.Irradiatorparametersshouldbekeptconstant,monitoredandrecordedduringdosemapping.Therecords,togetherwiththedosimetryresultsandallotherrecordsgenerated,shouldberetained.ElectronbeamirradiatorsDesignTheabsorbeddosereceivedbyaparticularportionofanirradiatedproductdependsprimarilyonthefollowingfactors:thecharacteristicsofthebeam,whichare:electronenergy,averagebeamcurrent,scanwidthandscanuniformity;theconveyorspeed;theproductcompositionanddensity;thecomposition,densityandthicknessofmaterialbetweentheoutputwindowandtheparticularportionofproduct;theoutputwindowtocontainerdistance.Keyparameterscontrolledbytheoperatorarethecharacteristicsofthebeamandtheconveyorspeed.DoseMappingForthedosemappingprocedure,dosimetersshouldbeplacedbetweenlayersofhomogeneousabsorbersheetsmakingupadummyproduct,orbetweenlayersofrepresentativeproductsofuniformdensity,suchthatatleasttenmeasurementscanbemadewithinthemaximumrangeoftheelectrons.Referenceshouldalsobemadetosections18to21.Irradiatorparametersshouldbekeptconstant,monitoredandrecordedduringdosemapping.Therecords,togetherwiththedosimetryresultsandallotherrecordsgenerated,shouldberetained.Re-commissioningCommissioningshouldberepeated訐thereisachangetotheprocessortheirradiatorwhichcouldaffectthedosedistributiontotheirradiationcontainer(e.g.changeofsourcepencils).Theextenttore-commissioningdependsontheextentofthechangeintheirradiatorortheloadthathastakenplace.Ifindoubt,re-commission.PremisesPremisesshouldbedesignedandoperatedtosegregateirradiatedfromnon-irradiatedcontainerstoavoidtheircross-contamination.Wherematerialsarehandledwithinclosedirradiationcontainers,itmaynotbenecessarytosegregatepharmaceuticalfromnonpharmaceuticalmaterials,providedthereisnoriskoftheformerbeingcontaminatedbythelatter.Anypossibilityofcontaminationoftheproductsbyradionuclidefromthesourcemustbeexcluded.ProcessingIrradiationcontainersshouldbepackedinaccordancewiththespecifiedloadingpattern(s)establishedduringvalidation.Duringtheprocess,theradiationdosetotheirradiationcontainersshouldbemonitoredusingvalidateddosimetryprocedures.Therelationshipbetweenthisdoseandthedoseabsorbedbytheproductinsidethecontainermusthavebeenestablishedduringprocessvalidationandplantcommissioning.Radiationindicatorsshouldbeusedasanaidtodifferentiatingirradiatedfromnonirradiatedcontainers.Theyshouldnotbeusedasthesolemeansofdifferentiationorasanindicationofsatisfactoryprocessing.Processingofmixedloadsofcontainerswithintheirradiationcellshouldonlybedonewhenitisknownfromcommissioningtrialsorotherevidencethattheradiationdosereceivedbyindividualcontainersremainswithinthelimitsspecified.Whentherequiredradiationdoseisbydesigngivenduringmorethanoneexposureorpassagethroughtheplant,thisshouldbewiththeagreementoftheholderofthemarketingauthorisationandoccurwithinapredeterminedtimeperiod.Unplannedinterruptionsduringirradiationshouldbenotifiedtotheholderofthemarketingauthorisation訐thisextendstheirradiationprocessbeyondapreviouslyagreedperiod.Non-irradiatedproductsmustbesegregatedfromirradiatedproductsatalltimes.Methodsofdoingthisincludetheuseofradiationindicators(31.)andappropriatedesignofpremises(28.).GammairradiatorsForcontinuousprocessingmodes,dosimetersshouldbeplacedsothatatleasttwoareexposedintheirradiationatalltimes.Forbatchmodes,atleasttwodosimetersshouldbeexposedinpositionsrelatedtotheminimumdoseposition.Forcontinuousprocessmodes,thereshouldbeapositiveindicationofthecorrectpositionofthesourceandaninterlockbetweensourcepositionandconveyormovement.Conveyorspeedshouldbemonitoredcontinuouslyandrecorded.Forbatchprocessmodessourcemovementandexposuretimesforeachbatchshouldbemonitoredandrecorded.Foragivendesireddose,thetimersettingorconveyorspeedrequiresadjustmentforsourcedecayandsourceadditions.Theperiodofvalidityofthesettingorspeedshouldberecordedandadheredto.ElectronBeamIrradiatorsAdosimetershouldbeplacedoneverycontainer.Thereshouldbecontin
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯系上傳者。文件的所有權益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網頁內容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
- 4. 未經權益所有人同意不得將文件中的內容挪作商業(yè)或盈利用途。
- 5. 人人文庫網僅提供信息存儲空間,僅對用戶上傳內容的表現方式做保護處理,對用戶上傳分享的文檔內容本身不做任何修改或編輯,并不能對任何下載內容負責。
- 6. 下載文件中如有侵權或不適當內容,請與我們聯系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 出口合同范本格式
- Unit 7 Be Wise with Money Period 3 Grammar 教學設計 2024-2025學年譯林版(2024)七年級英語上冊
- 勞務發(fā)包合同范本
- 動物投放景區(qū)合同范本
- 農村菜田出租合同范本
- 出租養(yǎng)殖雞場合同范本
- 加工定制窗簾合同范本
- 保潔商場合同范本
- 包地收款合同范本
- 勞務中介代理招聘合同范本
- 《神經外科常見疾病》課件
- 數字全息顯微成像的理論和實驗研究
- 科技引領全景式景區(qū)
- 單個軍人隊列動作教學法教案全(新條令)
- 西師版小學數學六年級下冊單元測試卷(含答案)
- 2024年公安機關理論考試題庫500道【綜合卷】
- (高清版)TDT 1048-2016 耕作層土壤剝離利用技術規(guī)范
- 市場調研與咨詢行業(yè)的市場調研方法創(chuàng)新培訓
- 2024年人工智能助力社會治理現代化
- 29.4常見腫瘤標志物講解
- 華為企業(yè)大學培訓體系
評論
0/150
提交評論