上海代表性家具城辦公項(xiàng)目工程模板施工方案_第1頁(yè)
上海代表性家具城辦公項(xiàng)目工程模板施工方案_第2頁(yè)
上海代表性家具城辦公項(xiàng)目工程模板施工方案_第3頁(yè)
上海代表性家具城辦公項(xiàng)目工程模板施工方案_第4頁(yè)
上海代表性家具城辦公項(xiàng)目工程模板施工方案_第5頁(yè)
已閱讀5頁(yè),還剩16頁(yè)未讀, 繼續(xù)免費(fèi)閱讀

下載本文檔

版權(quán)說(shuō)明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)

文檔簡(jiǎn)介

上海xxxx龍家居世博匯商業(yè)辦公項(xiàng)目模板施工方案江蘇省xxxx集團(tuán)有限公司上海xxxxxxxx項(xiàng)目部二〇一二年七月一日目錄一、工程概況··························································3二、編制依據(jù)··························································3三、各構(gòu)件模板支設(shè)要素及計(jì)算書(shū)·······························41.剪力墻(框架柱)模板支設(shè)要素及計(jì)算書(shū)············42.框架梁模板支設(shè)要素及計(jì)算書(shū)···························63.現(xiàn)澆板模板支設(shè)要素及計(jì)算書(shū)···························9四、模板支設(shè)要求···················································111.剪力墻及框架柱模板支設(shè)要求···························122.框架梁模板支設(shè)要求·······································123.現(xiàn)澆板模板支設(shè)要求·······································124.模板支設(shè)的其他注意事項(xiàng)·································12五、模板安裝檢驗(yàn)批質(zhì)量驗(yàn)收····································14六、模板施工的安全技術(shù)措施····································15七、模板拆除的技術(shù)要求··········································15八、模板工程應(yīng)急預(yù)案·············································16九、附圖·······························································201.剪力墻模板支設(shè)平面圖、立面圖························202.框架梁模板支設(shè)平面圖、剖面圖························213.現(xiàn)澆板模板支設(shè)平面圖、剖面圖························22上海xxxx龍家居世博匯商業(yè)辦公項(xiàng)目模板支設(shè)方案一、工程概況上海xxxx龍家居世博匯商業(yè)辦公項(xiàng)目,地處上海閔行區(qū),浦星公路東側(cè),聯(lián)航路北側(cè)。該項(xiàng)目地下一層,地上有30棟1~3層的別墅辦公樓,一棟四層裙房及其4棟12層辦公樓,一棟2層的售樓處。該建筑物為框架柱結(jié)構(gòu),地下室建筑面積為85771.2㎡,。地上建筑面積為186965.20㎡,總建筑面積為272736.4㎡。根據(jù)工程圖紙?jiān)O(shè)計(jì)進(jìn)度將本工程劃分為兩個(gè)施工階段,第一個(gè)施工階段為地下室部分,第二施工階段為地上部分。地下室部分的工程設(shè)計(jì)概況見(jiàn)下表項(xiàng)目名稱設(shè)計(jì)概況層高地下室底板面結(jié)構(gòu)標(biāo)高-6.30,地下室頂板結(jié)構(gòu)面標(biāo)高-1.20,層高為5.1m框架主次梁框架主梁的截面為600×1100次梁截面400×800地下室頂板現(xiàn)澆頂板200厚剪力墻高度5.1m框架柱柱網(wǎng)尺寸8.5m×8.5m框柱截面700×700800×8001100×10001100×1100本工程模板支設(shè)依據(jù)工程設(shè)計(jì)概況及相關(guān)規(guī)范要求,采用Φ48×3.0鋼管、扣件、δ=12厚的木工板、45×90木方、Φ14螺桿,進(jìn)行搭設(shè)。搭設(shè)方案共分三部分。第一部分為剪力墻模板支設(shè)(框架柱參造此搭設(shè)方案)。第二部分為框架梁模板支設(shè)。第三部分為現(xiàn)澆板模板支設(shè)。所用材料的力學(xué)參數(shù)模板δ=12,E=6000N/mm2,[f]=15N/㎡,[u]=1/250木方45×90,E=9500N/mm2,[f]=13N/㎡,[u]=1/250,[T]=1.3N/mm2鋼管Φ48×3.0,E=21000N/mm2,[f]=205N/mm2,[u]=1/400, W=5.08cm3,I=12.19cm4。Φ14的螺桿[N]=17.8t扣件抗滑移承載力設(shè)計(jì)值Rc=8KN。二、編制依據(jù):JGJ130-2001建筑施工扣件式鋼管腳手架安全技術(shù)規(guī)范JGJ80~91建筑施工高處作業(yè)安全技術(shù)規(guī)范相關(guān)工程圖紙三、各構(gòu)件模板支設(shè)要素及計(jì)算書(shū)(一)、剪力墻模板支設(shè)要素及計(jì)算書(shū)(框架柱參造此做法)1.剪力墻模板支設(shè)要素(1).模板采要900×1800×12的木工板,木工板上鉆Φ16的孔,孔縱橫間距為450.最底層一塊木工板鉆Φ16孔,孔沿豎向間距為450,沿水平間距為225。(2).內(nèi)楞采用45×90木方,木方間距為150。(3).外楞采用Φ48×3.0鋼管(雙鋼管),鋼管沿豎向間距為450。(4).內(nèi)外側(cè)的外楞鋼管用山形卡,Φ14螺桿拉緊。2.剪力墻模板搭設(shè)計(jì)算書(shū)(按5.1m高計(jì)算)(1).模板側(cè)壓力計(jì)算FF1=0.22γtβ1β2V與F2=γcH兩者取最小值γ=24KN/m3t=5.714h(T=20℃)β1=1.0β2=0.85V=2.5m/nH=5.1mF1=0.22×24×5.714×1.0×0.85×(2.5)=40.55KN/m2F2=24×5.1=122.4KN/m2因F2>F1則取F0=F1=40.55KN/m2(2)、模板的面板計(jì)算①模板側(cè)壓力計(jì)算(按三跨連續(xù)梁計(jì)算)模板受砼側(cè)壓力40.55KN/m2傾倒砼時(shí)側(cè)壓力6KN/m2則模板最終受到的側(cè)壓力為1.2×40.55+1.4×6=57.06KN/m2②模板按抗彎強(qiáng)度驗(yàn)算(計(jì)算單元取450寬,按L=150三跨連續(xù)梁計(jì)算)模板承受的線荷載q=F×0.45=57.06×0.45=25.68KN/m=25.68N/mm模板截面抵抗矩W=bh2=×45×1.2×1.2=10.8cm3模板所產(chǎn)生的最大彎矩Mmax=ql2=×25.68×1502=57780N.mm模板所產(chǎn)生的內(nèi)應(yīng)力σ====5.35N/mm2由于σ=5.35N/mm2<[f]=15N/mm2則模板的強(qiáng)度滿足要求③模板的撓度驗(yàn)算μ=<[μ]I=bh3=×45×1.2×1.2×1.2=6.48cm4μ=0.677×=0.23mm[μ]===0.6mm由于μ=0.23mm<[μ]=0.6mm所以模板的撓度滿足要求④內(nèi)楞的抗彎強(qiáng)度驗(yàn)算(計(jì)算單位取150:按三跨連續(xù)梁計(jì)算,其跨度為450)內(nèi)楞的荷載由模板傳至q=57.06×0.15=8.56KN/mMmax=ql2==173340N.mmW=bh2=×45×(90)2=60750mm3σ===2.85N/mm2因σ=2.85N/mm2<[f]=13N/mm2則內(nèi)楞的強(qiáng)度滿足要求⑤內(nèi)楞的撓度驗(yàn)算I=bh3=×45×(90)3=2733750mm4μ=0.677×=0.09mm[μ]===1.8mmμ=0.09mm<[μ]=1.8mm則內(nèi)楞的撓度滿足要求⑥外楞的強(qiáng)度驗(yàn)算(計(jì)算單位取450,跨度取450,按三跨連續(xù)梁計(jì)算)外楞的荷載由內(nèi)楞傳至P=8.56×0.45=3.85KN外楞的最大彎矩Mmax=0.175pl=0.175×3.85×0.45=0.303KN.mσ===67.48N/mm2因σ=67.48N/m2<[f]=205N/m2則外楞的強(qiáng)度滿足要求⑦外楞的撓度驗(yàn)算μ=1.146PL3/100EI<[μ]=μ==0.16mm[μ]==1.13mm由于μ=0.16mm<[μ]=1.13mm所以外楞的撓度滿足要求⑧穿墻螺桿的驗(yàn)算N<[N]=fA=17.8t=178KNN=57.06×0.45×0.45=11.56KN由于N=11.56KN<[N]=178KN所以穿墻螺桿的強(qiáng)度滿足要求(二)、框架梁模板支設(shè)要素及計(jì)算書(shū)框架梁模板支設(shè)要素(1).梁邦模板、梁底模板采用900×1800×12木工板(2).梁底木楞采用45×90木方間距﹫200(3).梁底橫擔(dān)采用Φ48×3.0鋼管,橫擔(dān)的間距@480(4).梁側(cè)立桿采用Φ48×3.0鋼管,此立桿的縱向間距@960(5).梁底頂撐立桿采用Φ48×3.0鋼管,頂撐立桿縱向間距@960(6).梁底支撐系統(tǒng):①框架柱邊線外擴(kuò)300設(shè)立桿(若兩框架柱截面有大小,按截面較大者為標(biāo)準(zhǔn),若按小截面框架柱為準(zhǔn),遇大截面框架柱時(shí),大截面框架柱的立桿應(yīng)外擴(kuò))②按兩柱立桿的縱向距離布置梁側(cè)立桿,其間距小于1.0m(按柱網(wǎng)尺寸8.5m,柱截面700×700,設(shè)定其立桿間距0.96m)③梁底頂桿縱向間距0.96m④梁支撐系統(tǒng)縱橫向水平桿步距小于1.8m梁板搭設(shè)計(jì)算書(shū)(按梁600×1100斷面尺寸計(jì)算)(1).荷載計(jì)算(沿木方縱向線荷載)①鋼筋砼梁:q1=0.2×1.1×25=5.5KN/m②模板自重:q2=8×(0.6+1.1×2)×0.012÷0.6×0.2=0.896KN/m③振動(dòng)砼時(shí)活載和施工荷載:q3=(1+2)×0.2=0.6KN/m荷載組合:q=1.2(q1+q2)+1.4×q3=1.2×(5.5+0.896)+1.4×0.6=8.52KN/m(2).木方的抗彎強(qiáng)度驗(yàn)算(按三跨連續(xù)梁計(jì)算,梁跨l0=480)Mmax=ql2=×8.52×(480)2=196300.8N.mmσ===3.23N/mm2因σ=3.23N/mm2<[f]=13.0N/mm2木方的抗彎強(qiáng)度滿足要求(3)木方抗剪強(qiáng)度驗(yàn)算Qmax=0.6ql=0.6×8.52×480=2454NT=3Q/2bh<[T]T=3×2454/2×45×90=0.91N/mm2因T=0.91N/mm2<[T]=1.3N/mm2木方的抗剪強(qiáng)度滿足要求(4)木方的撓度驗(yàn)算μ==0.677×=0.12mm[μ]===1.92mm因μ=0.12mm<[μ]=1.92mm則木方的撓度滿足要求(5)梁底小橫擔(dān)鋼管抗彎強(qiáng)度驗(yàn)算梁底小橫擔(dān)的荷載由木方傳至P=0.45q=0.45×8.52=3.83KNMmax=0.333×3.83×0.48=0.61KN.mσ==120N/mm2<[f]=205N/mm2鋼管的強(qiáng)度滿足要求(6)梁底小橫擔(dān)支座反力計(jì)算RA=RC=0.833×P=0.833×3.83=3.19KNRB=2.666P=2.666×3.83=10.21KN由于中間支座的反力RB=10.21KN<[R]=8KN該支座抗滑移采用雙扣件(7)梁底小橫擔(dān)撓度驗(yàn)算μ=2.508×=0.42mm[μ]==1.2mmμ=0.42mm<[μ]=1.2mm梁底小橫擔(dān)的撓度滿足要求(8)梁底立桿穩(wěn)定性驗(yàn)算l0=K1·K2(h+2a)=1.163×1.007×(1.8+0.2)=2.34mλ=l0/i==148據(jù)λ=148查表ψ=0.347σ==69.40N/mm2<[f]=205N/mm2立桿的穩(wěn)定性滿足要求(9)梁底大橫桿抗彎強(qiáng)度驗(yàn)算大橫桿所受荷載由小橫擔(dān)傳至P=3.19KNMmax=0.175×3.19×0.96=0.54KN.mσ===106N/mm2<[f]=205N/mm2大橫桿抗彎強(qiáng)度滿足要求(10)梁底大橫桿跨中撓度驗(yàn)算μ=1.18×=1.18×=1.1mm[μ]==2.4mmμ<[μ]則大橫桿的撓度滿足要求(11)大橫桿的支座反力計(jì)算R=2.68×3.19×0.96=8.2KN由于R>[R]=8KN則大橫桿采用雙扣件(12)立桿的穩(wěn)定性驗(yàn)算l0=(1.8+0.1×2)=2.0mλ=l0/i==127據(jù)λ=127查表ψ=0.451σ===42.88N/mm2λ<[f]=205N/mm2則立桿的穩(wěn)定性滿足要求(三)、現(xiàn)澆板模板支設(shè)要素及計(jì)算書(shū)1.現(xiàn)澆板模板支設(shè)要素(1).立桿采用Φ48×3.0鋼管,縱橫向間距@850(2).板底橫擔(dān)采用Φ48×3.0鋼管,間距@850(或縱向或橫向)(3).板底木方采用45×90間距@300(4).模板采用δ=12木工板(5).現(xiàn)澆板頂撐立桿的縱橫向水平桿步距1800。2.現(xiàn)澆板模板支設(shè)計(jì)算書(shū)(現(xiàn)澆板按200厚計(jì)算)(1).荷載計(jì)算(計(jì)算單元取850)現(xiàn)澆板自重:q1=0.85×0.2×25=4.25KN/m施工活載:q2=0.85×(1+2)=2.55KN/m荷載組合:q=1.2q1+1.4q2=1.2×4.25+1.4×2.55=8.67KN/m(2).木模板抗彎強(qiáng)度驗(yàn)算Mmax=ql2=×8.67×(300)2=78030N.mmW=bh2=×850×(12)2=20400mm3σ===3.83N/mm2因σ=3.83N/mm2<[f]=15N/mm2則模板的強(qiáng)度滿足要求(3).木模板撓度驗(yàn)算μ=<[μ]I=bh3=×850×(12)3=122400mm4μ==0.65mm[μ]===1.2因μ<[μ],則木模板的撓度滿足要求(4).木方所承受荷載計(jì)算鋼筋砼自重:q1=0.3×0.2×25=1.5KN/m木模板自重:q2=0.3×0.12=0.29KN/m施工活載:q3=(1+2)×0.3=0.9KN/m荷載組合:q=1.2(q1+q2)+1.4q3=1.2×(1.5+0.29)+1.4×0.9=3.41KN/m(5).木方抗彎強(qiáng)度驗(yàn)算Mmax=ql2=×3.41×(850)2=246373N.mmσ===4.06N/mm2因σ=4.06N/mm2<[f]=13N/mm2則木方的強(qiáng)度滿足要求(6).木方的撓度驗(yàn)算μ=0.677=0.677×=0.46mm[μ]==3.4m由于μ<[μ],則木方的撓度滿足要求(7).鋼管楞的抗彎強(qiáng)度驗(yàn)算鋼管荷載由木方傳至P=0.85×3.41=2.90KNMmax=0.336PL=0.336×2.9×0.85=0.83KN.mσ===163.39N/mm2<[f]=205N/mm2則鋼管的強(qiáng)度滿足要求(8).鋼管的撓度驗(yàn)算μ=2.2×=2.2×=0.15mm[μ]===2.13mμ=0.15m<[μ]=2.13m則鋼管的撓度滿足要求(9).鋼管楞的支座反力計(jì)算R=3.63×2.9×0.85=8.9KN因R=8.9KN>[R]=8KN,則扣件采用雙扣件(10).鋼管支撐立桿穩(wěn)定性驗(yàn)算l0=(1.8+0.1×2)=2.0mλ=l0/i==127據(jù)λ=127,查表ψ=0.451σ===46.54N/mm2σ=46.54N/mm2<[f]=205N/mm2則鋼管支撐立桿的穩(wěn)定性滿足要求四、模板支設(shè)要求1.剪力墻及框架柱模板支設(shè)要求:(1).剪力墻、框柱鋼筋隱蔽工程驗(yàn)收合格后方可進(jìn)行封板。為了保證模板支設(shè)工作的順利,模板支設(shè)前首先對(duì)剪力墻及框架柱鋼筋骨架進(jìn)行校正,校正時(shí)要進(jìn)行臨時(shí)撐拉.(2).剪力墻、框架柱模的木方間距小于等于150mm,Φ14螺桿的間距小于等于450mm,外楞采用雙鋼管,外楞間距小于等于450mm.(3).地下室外墻底部有先后澆筑砼墻,新、舊砼墻交界處用預(yù)埋螺桿拉緊模板并用海綿膠帶封閉模板與墻體的空隙.(4).觸地的剪力墻、框架柱模板檢查合格后,根部要進(jìn)行封閉處理.用1:2水泥砂漿封堵空隙,在適當(dāng)位置增設(shè)Φ20涉水孔.(5).由于剪力墻、框架柱較高,為防止模板脹裂,要求離底部1.8m以下采用雙螺帽.(6).剪力墻、框架柱模板的陽(yáng)角的外楞鋼管要用扣件扣緊,陰角的模板處增設(shè)木方,其木方要用外楞鋼管抵緊.(7).為防止剪力墻、框架柱模板產(chǎn)生彎曲、扭曲變形,在其構(gòu)件模板的中間部位要與排架的支撐系統(tǒng)固定.(8).梁板柱節(jié)點(diǎn)處的模板不宜太碎,并要求固定牢固,梁柱節(jié)點(diǎn)模板要求方正.(9).模板在砼澆筑前一天澆水濕潤(rùn).(10).木方與外楞之間的空隙要用木楔頂緊。2.框架梁模板支設(shè)要求:(1).梁底模的木方間距小于200mm.(2).梁底木方擱置在鋼管橫楞上和附加的鋼管橫楞上,橫冷的間距小于500mm.(3).梁底橫楞擱置在大橫楞上或直接與梁支撐立桿用扣件扣緊.(4).在梁底橫楞的中間設(shè)置頂撐立桿.(5).梁底頂撐與梁側(cè)支撐設(shè)置成排架系統(tǒng):縱橫向水平桿的步距約1.8m左右.(6).梁模支撐系統(tǒng)在梁側(cè)離地20cm處,必須設(shè)置掃地桿.(7).為防止梁側(cè)模變形,宜采用螺桿固定梁側(cè)模,或在梁兩側(cè)模中間采用短木方,將側(cè)模抵緊在支撐立桿上.(必須雙側(cè)頂緊)(8).梁側(cè)支撐立桿按兩端框架柱外擴(kuò)300設(shè)置,并按設(shè)計(jì)的間距進(jìn)行布設(shè).(9).主次梁交接處的梁側(cè)支撐立桿應(yīng)按較大梁立桿間距設(shè)置成井架,并在其中間增加梁底頂撐,作為框架梁支撐系統(tǒng)的支座.(10).梁模板支設(shè)時(shí)要按設(shè)計(jì)要求進(jìn)行提拱(1/1000~3/1000)3.現(xiàn)澆板模板支設(shè)要求(1).板底木方的間距@300.(2).木方擱置在鋼管上,鋼管的間距@850.(3).鋼管橫楞采用鋼管立桿作支撐,鋼管支撐立桿的間距@850.(4).鋼管立桿離地200mm處設(shè)置掃地桿,縱橫向水平桿的步距約1.8m左右.4.模板支設(shè)的其他注意事項(xiàng):(1).工藝流程:①?gòu)棾鲋膺吘€、梁中心線,特別是主次梁交叉處中心線→②主次梁交叉處形成井架,框架柱處形成井架→③確定立桿間距(設(shè)置掃地桿,并將立桿固定)→④按照步距先將X向水平桿與立桿進(jìn)行固定,搭設(shè)過(guò)程中必須校正Y向(X向)的立桿垂直度→⑤按照步距再將Y向水平桿與立桿進(jìn)行固定,搭設(shè)過(guò)程中必須校正X向立桿垂直度→⑥設(shè)置邊跨、中間跨水平剪刀撐或支形撐→⑦逐步向上搭設(shè)→⑧梁底部大橫桿與梁側(cè)立桿支撐扣緊(雙扣件)梁起拱→⑨設(shè)置梁底橫楞鋼管并與大橫桿綁牢→⑩設(shè)置梁底頂撐立桿并與水平桿綁牢→eq\o\ac(○,11)設(shè)置梁底模以及支撐系統(tǒng)的豎向剪刀撐(現(xiàn)澆板支撐系統(tǒng)的搭設(shè)參照此方法)(每跨中間部位設(shè)置)(2).剪力墻模板支設(shè)時(shí),應(yīng)注意墻板上后澆帶模板的支設(shè),要求后澆帶內(nèi)的模板(網(wǎng)片)能抗砼沖擊不漏漿不跑模.(3).要求模板接縫嚴(yán)密不漏漿.(4).梁柱節(jié)點(diǎn)處模板方正,并且固定牢固.(5).考慮方便拆模,現(xiàn)澆板模板擱置在梁模、柱模之上.(6).考慮模板的周轉(zhuǎn)使用,后澆帶模板系統(tǒng)及其支撐系統(tǒng)要有獨(dú)立性.(7).豎向構(gòu)件底部的側(cè)壓力大,底部1.8m以下的模板固定螺桿采用雙螺帽.(8).砼澆筑時(shí),模板提前一天澆水濕潤(rùn),豎向構(gòu)件模板要有泄水孔.(9).模板支撐系統(tǒng)的扣件要經(jīng)驗(yàn)收后方可澆筑砼(用力矩扳手抽檢扣件螺帽擰緊力矩),并清除模板內(nèi)垃圾.(10).嚴(yán)禁振搗砼時(shí),振動(dòng)棒對(duì)鋼筋或模板過(guò)振.(11).鋼管的接頭不允許在統(tǒng)一位置,應(yīng)錯(cuò)開(kāi)500mm。相鄰立桿接頭不應(yīng)設(shè)在同步內(nèi),同步內(nèi)隔根立桿的接頭應(yīng)錯(cuò)開(kāi)500,各接頭中心至各節(jié)點(diǎn)宜大于1/3步距.(12).豎向剪刀撐必須觸地.(13).鋼管支撐在500厚C30砼底板上,對(duì)于虛空的立桿底部應(yīng)墊實(shí).(14).模板支撐架體沿邊跨每一跨(跨度為8.4m)中間設(shè)置連續(xù)的豎向(X向和Y向)斜撐,斜撐必須觸地。隔跨設(shè)置水平剪力撐(掃地桿處、頂層必須設(shè)置、中間隔步設(shè)置)。(15)砼澆筑時(shí),不宜將固定泵與支撐架體相連,應(yīng)先澆砼柱和澆剪力墻,再澆梁板。六、模板施工的安全技術(shù)措施:模板工程作業(yè)高度在2m和2m以上時(shí),應(yīng)根據(jù)高空作業(yè)安全技術(shù)規(guī)范的要求進(jìn)行操作和防護(hù),在4m以上或二層及二層以上周圍應(yīng)設(shè)安全網(wǎng)和防護(hù)欄桿。支模應(yīng)按規(guī)定的作業(yè)程序進(jìn)行,模板未固定前不得進(jìn)行下一道工序。嚴(yán)禁在連接件和支撐件上攀登上下,并嚴(yán)禁在上下統(tǒng)一垂直面安裝、拆模板。支設(shè)高度在3m以上的柱模板,四周應(yīng)設(shè)斜撐,并應(yīng)設(shè)立操作平臺(tái),低于3m的可用馬凳操作。支設(shè)懸挑形式的模板時(shí),應(yīng)有穩(wěn)定的立足點(diǎn)。支設(shè)臨空構(gòu)筑物模板時(shí),應(yīng)搭設(shè)支架。模板上有預(yù)留洞時(shí),應(yīng)在安裝后將洞蓋住?;炷涟宀鹉:笮纬傻呐R邊后洞口,應(yīng)按規(guī)定進(jìn)行防護(hù)。操作人員上下通行時(shí),不許攀登模板或腳手架,不許在墻頂、獨(dú)立梁及其他狹窄而無(wú)防護(hù)欄的模板面上行走。模板支撐不能固定在腳手架或門(mén)窗上,避免發(fā)生倒塌或模板位移。在模板上施工時(shí),堆物不宜過(guò)多,不宜集中一處,大模板的堆放應(yīng)有防傾覆措施。(8)、拆模安全注意事項(xiàng):①拆除時(shí)模板必須隨拆隨清理,以避免釘子扎腳或阻礙交通發(fā)生事故。②拆模時(shí)不能采取猛撬,以免模板大面積塌落砸傷施工人員。③模板拆除時(shí)嚴(yán)禁高空拋擲。④拆除的模板在樓層上不得集中堆放。⑤拆模時(shí),地面上設(shè)警戒區(qū),有專人看護(hù)。七、模板拆除的技術(shù)要求:模板拆除時(shí)構(gòu)件砼強(qiáng)度等級(jí)滿足要求(參考以下表格)現(xiàn)澆結(jié)構(gòu)承重模板拆除時(shí)所需砼強(qiáng)度項(xiàng)次構(gòu)件類型結(jié)構(gòu)跨度按砼達(dá)到設(shè)計(jì)強(qiáng)度標(biāo)準(zhǔn)值的百分率%1板≤250>2、≤875>81002梁、板、殼≤875>81003懸臂構(gòu)件≤275>2100非承重模板應(yīng)在砼強(qiáng)度能保證構(gòu)件不缺棱掉角方可拆除。承重模板拆除執(zhí)行,先支后拆的原則,并按照項(xiàng)目部書(shū)面通知規(guī)定的時(shí)間方可拆除。已拆除模板及其支撐的砼構(gòu)件,應(yīng)在砼強(qiáng)度達(dá)到設(shè)計(jì)標(biāo)準(zhǔn)值后,才允許承受全部使用荷載,達(dá)不到標(biāo)準(zhǔn)值時(shí),應(yīng)加設(shè)臨時(shí)支撐。八、模板工程的應(yīng)急預(yù)案:高處墜落和物體打擊事故應(yīng)急救援預(yù)案一旦發(fā)生高處墜落和物體打擊事故后,項(xiàng)目部應(yīng)立即組織人員進(jìn)行搶救,并電話通知公司應(yīng)急反應(yīng)組織機(jī)構(gòu),同時(shí)迅速呼叫醫(yī)務(wù)人員前來(lái)現(xiàn)場(chǎng)進(jìn)行搶救。迅速排除致命和致傷因素:如搬開(kāi)壓在身上的重物;清除傷病員口鼻內(nèi)的泥砂、嘔吐物、血塊或其他異物,保持呼吸道通暢等。檢查傷員的生命體征:檢查傷病員呼吸、心跳、脈搏情況。如有呼吸心跳停止,應(yīng)就地立刻進(jìn)行心臟按摩和人工呼吸。止血:有創(chuàng)傷出血者,應(yīng)迅速包扎止血,材料就地取材,可用加壓包扎、上止血帶或指壓止血等。同時(shí)盡快送往醫(yī)院。觀察受傷人員摔傷及骨折部位,看其是否昏迷;注意摔傷及骨折部位的保護(hù),避免不正確的抬運(yùn),使骨折錯(cuò)位而造成二次傷害。車輛一到立即就近送往醫(yī)院。由事故調(diào)查組進(jìn)行事故調(diào)查,責(zé)任分析并形成調(diào)查報(bào)告上報(bào)上級(jí)主管部門(mén)??偨Y(jié)經(jīng)驗(yàn)教訓(xùn),教育職工。2、觸電事故應(yīng)急救援預(yù)案如果發(fā)生觸電事故時(shí)首先斷開(kāi)電源。項(xiàng)目部應(yīng)立即組織人員進(jìn)行搶救,并電話通知公司應(yīng)急反應(yīng)組織機(jī)構(gòu),同時(shí)迅速呼叫醫(yī)務(wù)人員前來(lái)現(xiàn)場(chǎng)進(jìn)行搶救。如果電源開(kāi)關(guān)在較遠(yuǎn)處,則可用絕緣材料(如木條等)把觸電者與電源分離。高壓線路觸電:馬上通知供電部門(mén)停電,如一時(shí)無(wú)法通知供電部門(mén)停電則可拋擲導(dǎo)電體(如裸導(dǎo)線),讓線路短路跳閘,再把觸電者拖離電源。觸電者脫離電源后馬上進(jìn)行搶救,同時(shí)通知110送往最近的醫(yī)院。由事故調(diào)查組進(jìn)行事故調(diào)查,責(zé)任分析并形成調(diào)查報(bào)告上報(bào)上級(jí)主管部門(mén)??偨Y(jié)經(jīng)驗(yàn)教訓(xùn),教育職工。3、機(jī)械傷害應(yīng)急救援預(yù)案一旦發(fā)生機(jī)械傷害事故后,項(xiàng)目部應(yīng)立即切斷電源并組織人員進(jìn)行搶救,并電話通知公司應(yīng)急反應(yīng)組織機(jī)構(gòu),同時(shí)迅速呼叫醫(yī)務(wù)人員前來(lái)現(xiàn)場(chǎng)進(jìn)行搶救。對(duì)傷員進(jìn)行必要的處理,如止血:有創(chuàng)傷出血者,應(yīng)迅速包扎止血,材料就地取材,可用加壓包扎、上止血帶或指壓止血等。同時(shí)盡快送往醫(yī)院。車輛一到立即就近送往醫(yī)院。事故調(diào)查組進(jìn)行事故調(diào)查,責(zé)任分析并形成調(diào)查報(bào)告上報(bào)上級(jí)主管部門(mén)。總結(jié)經(jīng)驗(yàn)教訓(xùn),教育職工。4、模板、腳手架坍塌一旦發(fā)生模板、腳手架坍塌事故,現(xiàn)場(chǎng)搶救組應(yīng)首先進(jìn)行疏散,清點(diǎn)人員,確定有無(wú)人員失蹤、受傷。了解事發(fā)前該區(qū)域施工人員情況,作業(yè)人數(shù),如有施工人員失蹤或被壓埋,立即組織有效的挖掘、移除工作。挖掘、移除應(yīng)采用人工挖掘、移除,禁止采用機(jī)械挖掘、移除,防止及機(jī)械對(duì)被埋人員造成傷害。人工挖掘、移除盡量避免使用尖銳性工具。搶救挖掘、移除人員應(yīng)分班組,合理按照工作面安排人力,及時(shí)換班,保障搶救挖掘、移除人員體力,保證在最短時(shí)間內(nèi)將被壓埋人員搶救出來(lái)。如有人員失蹤、受傷,安全保衛(wèi)組應(yīng)立即報(bào)警。并做好救助車輛引導(dǎo)。在專業(yè)醫(yī)療人員到達(dá)前由現(xiàn)場(chǎng)傷員搶救組對(duì)受傷人員進(jìn)行簡(jiǎn)單救助。爭(zhēng)分奪秒搶

溫馨提示

  • 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。

評(píng)論

0/150

提交評(píng)論