GB 50689-2011 GB50689-2011通信局(站)防雷與接地工程設(shè)計規(guī)范:英文_第1頁
GB 50689-2011 GB50689-2011通信局(站)防雷與接地工程設(shè)計規(guī)范:英文_第2頁
GB 50689-2011 GB50689-2011通信局(站)防雷與接地工程設(shè)計規(guī)范:英文_第3頁
GB 50689-2011 GB50689-2011通信局(站)防雷與接地工程設(shè)計規(guī)范:英文_第4頁
GB 50689-2011 GB50689-2011通信局(站)防雷與接地工程設(shè)計規(guī)范:英文_第5頁
已閱讀5頁,還剩100頁未讀, 繼續(xù)免費閱讀

付費閱讀全文

版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進行舉報或認(rèn)領(lǐng)

文檔簡介

專用

人人文庫

NATIONALSTANDARD

OFTHEPEOPLESREPUBLICOFCHINA

CodeforDesignofLightningProtectionandEarthing

EngineeringforTelecommunicationBureaus(Stations)

GB50689-2011

ChiefDevelopmentDepartment:MinistryofIndustryandInformationTechnology

ofthePeoplesRepublicofChina

ApprovalDepartment:MinistryofHousingandUrbanRuralDevelopment

-

ofthePeoplesRepublicofChina

ImplementationDate:May1,2012專用

人人文庫

ChinaPlanningPress

Beijing2019

ChineseeditionfirstpublishedinthePeoplesRepublicofChinain2011

EnglisheditionfirstpublishedinthePeoplesRepublicofChinain2019

byChinaPlanningPress

rd

,,專用

3FloorCTowerGuohongBuilding

No.A11,Muxidi-Beili,XichengDistrict

Beijing,100038

PrintedinChinabyFactoryattachedtoBeijingInstituteofGraphicCommunication

?2011byMinistryofHousingandUrban-RuralDevelopmentof

thePeoplesRepublicofChina

Allrightsreserved.Nopartofthispublicationmaybereproducedortransmittedinanyformor

byanymeans人人文庫,graphic,electronic,ormechanical,includingphotocopying,recording,

oranyinformationstorageandretrievalsystems,withoutwrittenpermissionofthepublisher.

Thisbookissoldsubjecttotheconditionthatitshallnot,bywayoftradeorotherwise,belent,

resold,hiredoutorotherwisecirculatedwithoutthepublisherspriorconsentinanyformof

blindingorcoverotherthanthatinwhichthisispublishedandwithoutasimilarcondition

includingthisconditionbeingimposedonthesubsequentpurchaser.

ISBN978-7-5182-1097-8

AnnouncementoftheMinistryofHousingandUrban-Rural

DevelopmentofthePeoplesRepublicofChina

No.981

AnnouncementonPublishingtheNationalStandardof

CodeforDesignofLightningProtectionandEarthing

EngineeringforTelecommunicationBureaus(Stations)

CodeforDesignofLightningProtectionandEarthingEngineeringforTelecommunication

Bureaus(Stations)hasbeenapprovedasanationalstandardwithaserialnumberofGB50689-2011

andshallbeimplementedfromMay1,2012.Articles1.0.6、3.1.1、3.1.2、3.6.8、3.9.1、3.10.3、3.11.2、

3.13.6、3.14.1、4.8.1、5.3.1、5.3.4、6.4.3、6.6.4、7.4.6、9.2.9aremandatoryandmustbeenforcedstrictly.

AuthorizedbytheStandardRatingResearchInstituteoftheMinistryofHousingandUrbanRural

專用-

DevelopmentofthePeoplesRepublicofChina,thisstandardispublishedbyChinaPlanningPress.

MinistryofHousingandUrbanRuralDevelopmentofthePeoplesRepublicofChina

-

April2,2011

人人文庫

Foreword

ThiscodeisformulatedbyChinaInformationTechnologyDesigningandConsultingInstitute

Co.,Ltd.accordingtotherequirementsofDocumentJianBiao〔2008〕No.105issuedbyMinistryof

HousingandUrbanRuralDevelopment"NoticeofPrintingandDistributingtheDevelopmentand

--

RevisionPlan(Secondpitch)ofNationalEngineeringConstructionStandardsin2008".

Duringtheformationofthiscode,theformationteamhasstudiedlotsofthecurrentnationallaws,

regulationsandstandards,maderelevantinvestigations,summarizedyearsofexperienceonthedesign

oflightningprotectionandearthingengineeringforTelecommunicationBureaus(Stations),repeatedly

discussedandmodifiedprovisionsofthiscodeandfinalizedthecodeafterexaminationbasedonsolicit

opinionsfromallsides.

Thiscodecomprises9chaptersand7appendixeswiththemaincontentsasfollows:general

provisions,terms,basicrequirements,thelightningprotectionandearthingofcomprehensive

telecommunicationbuilding,thelightningprotectionandearthingofcabletelecommunicationbureaus

(stations),thelightningprotectionandearthingofmobiletelecommunicationbasestation,the

lightningprotectionandearthingofsmalltelecommunicationstation,thelightningprotectionand

earthingofmicrowaveandsatelliteearstationsandthedesignoflightning專用overvoltageprotectionfor

-

telecommunicationbureaus(stations)andsoon.

Theprovision(s)printedinboldtypeis(are)compulsoryone(ones)andmustbeenforcedstrictly.

MinistryofHousingandUrbanRuralDevelopmentisinchargeoftheadministrationofthiscode

-

andtheexplanationofthecompulsoryprovisions.ChinaInformationTechnologyDesigningand

ConsultingInstituteCo.,Ltd.isresponsiblefortheexplanationofspecifictechnicalcontents.All

relevantorganizationsarekindlyrequestedtosumupandaccumulateyourexperiencesinactual

practicesduringtheprocessofimplementingthiscode.RelevantopinionscanbepostedtoChina

InformationTechnologyDesigningandConsultingInstituteCo.,Ltd.(Address:ZhuYuCommercial

Center,No.5ShouTiNanRD,HaiDianDistrict,Beijing,Postcode:100048)forreferenceofrevision

infuture.

:

ChiefDevelopmentOrganization

ChinaInformationTechnologyDesigningandConsultingInstituteCo.,Ltd

:

ChiefDraftingStaff

人人文庫LiuJikeZhuQingfengChenQiangShiYuhaiWangZhigangQiZheng

NiuNianzeng

:

ChiefExaminationStaff

YangShizhongLinYongshuangGaoJianXuWeijieLiZhi

ZhangDongliangGuoYapingDaiChuanyouGuoWuSunYanling

QiuChuanruiLouJieliangXiaoBoLuZhiJun

Contents

1GeneralProvisions……………(1)

2Terms…………………………(2)

3BasicRequirements……………(6)

3.1GeneralRequirements…………(6)

3.2CompositionofEarthingSystem…………………(6)

3.3EarthElectrode…………………(7)

3.4EarthingConnection……………(8)

3.5MainEarthingConductor………………………(8)

3.6EarthingConductor……………(8)

3.7TheTypesofEquipotentialBonding………………(9)

3.8TheAccessingWaysofVariousCables……………(10)

3.9TheLayoutRequirementsofEarthingConductor……………………(10)

3.10TheProtectionoftheComputerNetworkInterfaceandControlTerminalInterface……(10)

3.11TheEarthingofCentralizedMonitoringSystemandtheInterfaceProtection專用…………(11)

3.12TheLayoutofCablesintheBureau………………(11)

3.13PowerDistributionSystem………………………(11)

3.14TheEarthingofAuxiliaryEquipmentintheEquipmentRoom………(12)

3.15TheLightningProtectionandEarthingofOpticalFiberCable………(12)

4TheLightningProtectionandEarthingofComprehensiveTelecommunicationBuilding……(15)

4.1GeneralRequirements…………(15)

4.2TheTypesofEarthingandBonding………………(16)

4.3TheTypesofInternalEquipotentialBonding………(19)

4.4EarthGrid……………………(19)

4.5TheEarthingoftheCablesEnteringintoBureau……………………(20)

4.6TheEarthingofTelecommunicationEquipment……………………(20)

4.7TheEarthingofPowerSupplySystem……………(23)

4.8TheEarthingofOtherFacilities…………………(23)

4.9TheLightning人人文庫ProtectionDesignofBuilding………(24)

5TheLightningProtectionandEarthingofCableTelecommunicationBureaus(Stations)…(25)

5.1ExchangeBureauandDataBureau………………(25)

5.2AccessNetworkStationandModuleBureau………(26)

5.3BroadbandAccessSites…………(27)

5.4FiberCableRepeaterStation……………………(28)

5.5TheEarthingofDCPowerDistributionSystemforTelecommunicationEquipment……(28)

6TheLightningProtectionandEarthingofMobileTelecommunicationBaseStation…………(29)

6.1GeneralRequirements…………(29)

6.2EarthGrid……………………(29)

·1·

6.3DirectStrokeProtection…………(31)

6.4TheEarthingofAntennaandFeedingCable………(31)

6.5TheLightningProtectionandEarthingofDCRemoteFeedingSystem…………………(32)

6.6TheLightningProtectionofEarthingofGPSAntennasandFeedingCables……………(33)

6.7InternalEquipotentialBonding……………………(33)

6.8TheHandlingofEarthingConnectionandIndoorEarthing……………(34)

6.9TheEarthingofOtherAccessingCables……………(35)

6.10TheEarthingofDCPowerDistributionSystemforTelecommunicationEquipment……(35)

7TheLightningProtectionandEarthingofSmallTelecommunicationStation………………(36)

7.1GeneralRequirements…………(36)

7.2EarthGrid……………………(36)

7.3DirectLightningProtection………………………(37)

7.4Others…………………………(38)

8TheLightningProtectionandEarthingofMicrowaveandSatelliteStations…(39)

8.1TheLightningProtectionandEarthingofMicrowaveStations………(39)

8.2TheLightningProtectionandEarthingofSatelliteStations…………(41)

9TheDesignofLightningOverVoltageProtectionforTelecommunication

-

Bureaus(Stations)……………(42)

9.1GeneralRequirements…………專用(42)

9.2TheApplicationRequirementsofSPD……………(42)

9.3ThePrinciplesofLightningOverVoltageProtectionforthePowerSystemin

-

TelecommunicationBureaus(Stations)……………(43)

9.4TheInstallationRequirementsofPowerSPD………(49)

9.5ThePrinciplesofLightningOverVoltageProtectionDesignforComputerNetworksandSignalCables……(50)

-

AppendixATheStatisticsTablesoftheAverageNumberofThunderstormDaysin

OneYearonMajorCities…………(52)

AppendixBTheNationwideZonedMapoftheAverageNumberofThunderstormDays

inOneYear…………(54)

AppendixCTheRequirementsofSPDProtectionMode………(55)

AppendixDMesh,StarandStarMeshMixedEarthingSystem………………(56)

-

AppendixETheTestofEarthingResistance……………………(57)

AppendixFTheMeasurementofEarthResistivity……………(59)

AppendixGLightning人人文庫ProtectionZones…………(61)

ExplanationofWordinginThisCode……………(63)

ListofQuotedStandards…………(64)

Addition:ExplanationofProvisions………………(65)

·2·

1GeneralProvisions

Thiscodeisformulatedwithaviewtopreventingorreducingthedangeroflightningstrokeat

1.0.1

telecommunicationbureaus(stations),ensuringthesafetyofthepersonnelandalsoensuringthe

telecommunicationequipmentundersafetyandnormalworkconditions.

Thiscodeisapplicabletothedesignoflightningprotectionandearthingengineeringfor

1.0.2

construction,reconstructionandextensionoftelecommunicationbureaus(stations).

Thelightningprotectionandearthingengineeringoftelecommunicationbureaus(stations)shall

1.0.3

beconstructedbasedoncommonearthing,voltagesharingequipotentialandpartitionedprotection,

-

andtheinstallationpositionofSPD(SurgeProtectiveDevice)shallbeplannedreasonablyaccordingto

thetheoryofelectromagneticcompatibilityandtheprincipleoflightningprotectionzones.

Theriskassessmentonlightningstrokeforthedesignoflightningprotectionandearthing

1.0.4

engineeringfortelecommunicationbureaus(stations)shallbebasedonfieldinvestigationdata,

geographicalenvironment,annualthunderstormdaysandtypesofthetelecommunicationbureaus

(stations).

SPDsselectedforlightningovervoltageprotectionprojects專用shallcomplywithtechnical

1.0.5-

requirementsontelecommunicationlightningprotectionproductsoftheMinistryofIndustryand

InformationTechnology.

1.0.6OnlythosequalifiedSPDstestedbyathirdpartytestingdepartmentaccreditedbythestate

mustbeselectedforlightningover-voltageprotectionprojectsoftelecommunicationbureaus

()

stations.

Theannualthunderstormdaysshallbedeterminedaccordingtodataprovidedbythelocal

1.0.7

meteorologicaldepartmentsoftelecommunicationbureaus(stations)ortheprovisionsofAnnexAand

Binthiscode.

Forthedesignoflightningprotectionandearthingengineeringoftelecommunicationbureaus

1.0.8

(stations),notonlytherequirementsstipulatedinthiscodebutalsothoseinthecurrentrelevant

standardsofthenationshallbecompliedwith.

人人文庫

·1·

2Terms

Lightningprotectionzones(LPZ)

2.0.1

Azoneeasilytobeaffectedbylightningstrokeisclassifiedtobetheprotectedzonesinaccordance

withthedifferencesoftheinsideandtheoutsideofbuildings,environmentsoftelecommunication

roomsandprotectedequipmentoftelecommunicationbureaus(stations).Suchprotectedzonesare

calledthelightningprotectionzones.

Thunderstormday

2.0.2

Athunderstormdaymeansonedaywhenmorethanonethundermaybeheard.

Lowkerauniczones

2.0.3

Lowkerauniczonesarethoseareaswheretheaveragenumberofthunderstormdaysinoneyearis

nomorethan25.

Middlekerauniczones

2.0.4

Middlekerauniczonesarethoseareaswheretheaveragenumberofthunderstormdaysinoneyear

iswithinarangeof26-40.

Highkerauniczones專用

2.0.5

Highkerauniczonesarethoseareaswheretheaveragenumberofthunderstormdaysinoneyearis

withinarangeof41-90.

Strongkerauniczones

2.0.6

Strongkerauniczonesarethoseareaswheretheaveragenumberofthunderstormdaysinoneyear

ismorethan90.

Kerauniczones

2.0.7

Thekerauniczonesareclassifiedintolowkerauniczones,middlekerauniczones,highkeraunic

zonesandstrongkerauniczonesaccordingtoaveragenumbersofannualthunderstormdays.

Evaluationoflightningstrikerisk

2.0.8

Itisamethodtohavecomprehensiveevaluationonextentofdamageofthebureaus(stations)due

tolightningstroketotheearthandthendeterminelevelsandclassesofprotection,inaccordancewith

variousfactorsoflightningstroke.

Directlightningflash

2.0.9

Itisaflashdirectly人人文庫attackingbuildingsorlightningprotectionsystems.

Directstrokeprotection

2.0.10

Itisameasuretoprotectbuildings,structures,electricnetworksorelectricalinstallationsfrom

beingattackedbydirectlightningflash.

Airterminalsystem

2.0.11-

Itincludeslightningrods,lightningstrips(conductors)andlightningprotectionnetsthatreceive

lightningstrokedirectly.

Rollingspheremethod

2.0.12

Itisasimplifiedanalysismethodbyapplyingtheelectricgeometrictheorytolightningprotection

analysisofbuildings.

·2·

Downconductorsystem

2.0.13-

Itisametalconductorconnectedtotheairterminalsystemandtheearthterminationsystem.

--

Lightningelectromagneticpulse(LEMP)

2.0.14

Itisanelectromagneticradiationhavingrelationshipwithlightningdischarge.Theelectricfieldand

themagneticfieldgeneratedtherebywillbecoupledtotheelectricorelectronicsystem,thus

destructivesurgecurrentorsurgevoltagewillbeproduced.

Externallightningprotectionsystem

2.0.15

Comprisedofanairterminalsystem,adownconductorsystemandanearthterminationsystem,

---

itismainlyusedasaprotectiondevicetopreventdirectlightningflash.

Soilresistivity

2.0.16

Itisaparameterrepresentingtheconductivityofsoilofwhichthevalueisequaltotheresistance

measuredattwooppositefacesofunitcubeofsoil.TheunitthereofisΩ·m.

Powerfrequencygroundresistance

2.0.17

Itistheresistancebetweentheearthelectrodeandtheremoteearth,whenthepowerfrequency

currentpassesanearthterminationsystem.Itsvalueisequaltothespecificvaluebetweenthevoltageof

-

theearthterminationsystemtotheremoteearthandthecurrentflowingtotheearthviatheearth

-

electrode.

Commonearthing

2.0.18

Itisanearthingmethodwheredifferentearthingmethods專用forvarioustelecommunication

equipmentsattelecommunicationbureaus(stations),includingworkingearthingoftelecommunication

equipment,protectiveearthing,shieldearthing,staticelectricityprotectionearthing,logicgroundof

informationequipment,andetc.arecombinedwiththeprotectiveearthingofmetalcomponentsof

buildingsandlightningprotectionsystemsandSPD,whichshares,togetherwiththelightning

protectionandearthingsystemofthebuildings,thebasicearthelectrodesandexternalearthingsystems.

Earthelectrode

2.0.19

Itisapieceoragroupofconductor(s)closelycontactingwiththesoil(theearth)toprovidethe

electricalconnectionwiththesoil(theearth),forthepurposeofconnectingtotheearth.

Earthingconnection

2.0.20

Earthingconnectionmeanstheconnectinglinebetweentheearthelectrodeandthemainearthing

bar.

Earthingsystem

2.0.21

Itisacomplexsystemcoveringallelectricconnectionsanddevicesforearthingofsystems,

appliancesandequipment人人文庫,whichincludeearthelectrodesintheearth,earthingconductors,andcable

shieldinglayersconnectedtoearthelectrodes,andequipmentshellsconnectedtoearthelectrodesor

exposedmetalcomponents,rebarsorframesofbuildingsandsoon.

Earthgrid

2.0.22

Itisagroupofearthelectrodescomprisedofbareconductorswhichareinterconnectedintheearth,

forthepurposeofprovidingcommonearthforelectricalequipmentsormetalstructures.

Earthterminationsystem

2.0.23-

Itisanaggregationofearthingconductorsandearthelectrodes.

Equipotentialbonding

2.0.24

Connecttheseparateddevicesandvariousconductiveobjectsusingequipotentialbonding

·3·

conductorsorSPDs,soastoreducethepotentialdifferenceamongthemcausedbylightningcurrent.

Equipotentialbondingnetwork

2.0.25

Itisanetworkcomprisedofequipotentialbondingconductorsbywhichvariousexposed

conductivepartsofonesystemareconnected.

Earthingreferencepoint(ERP)

2.0.26

Itistheonlyoneconnectionpointbetweenthecommonearthingsystemandtheequipotential

bondingnetworkofsystem.

Mainearthingconductor

2.0.27

Itmeansthestripcopperbarorthesteelflatusedastheearthingconductor,whichisusuallyused

asthetrunklineoftheearthingsysteminsidethetelecommunicationbureaus(stations),andby

methodsoflaying,itcanbeclassifiedintothehorizontalmainearthingconductor,theverticalmain

earthingconductor,theringmainearthingconductororthebartypemainearthingconductor.

-

Earthingterminal

2.0.28

Itistheconnectionterminalofearthingconductorortheearthingbar.

Earthingbar

2.0.29

Itisconnectedwiththeearthingbus,andusedastherectangularcopperbarforconnection

terminalofvariousearthingconductors.

MainEarthingTerminal(MET)

2.0.30

Itistheearthingbartoconnectvariousearthingconductorswiththe專用earthterminationsystem,and

-

itisalsothefirststageearthingbarofthesystem.

Floorearthingbar(FEB)

2.0.31

Earthingbarsmountedateachfloorinbuildingsareusedforthepurposeofequipotentialbonding

bylocalearthingbars.

Localearthingbar(LEB)

2.0.32

Itistheearthingbarbeingusedinsidetheequipmentroomoftelecommunicationsystemforthe

purposeoflocalequipotentialbonding.

Cableentranceearthingbar(CEEB)

2.0.33

Itisanearthingbartoconnectoutdoorcablesofcableentrancefacilitywithmainearthing

terminalsorringearthelectrodes.

Cableentrancefacility(CEF)

2.0.34

Itisafacilitytoconnectthebuiltinearthingofcablewiththemetalskinforthepurposeof

-

earthing,anditshallbeasclosetotheentranceofoutdoorcableaspossibleaccordingtothepractical

situation.人人文庫

CommonDCreturn(DCC)

2.0.35-

ItisaDCpowersystemwhichallowstheDCreturnconductortohavemultipointconnectionwith

surroundingbondingnetworks.

IsolatedDCreturn(DCI)

2.0.36-

ItisaDCpowersystemwhichallowstheDCreturnconductortohavesinglepointconnectionto

-

BN.

Commonbondingnetwork(CBN)

2.0.37

Itisthemainmethodforconnectionandearthingattelecommunicationbureaus(stations),a

groupofmetalpartswhichareinterconnectedwithspecialintentionorbyaccidentandusedformain

·4·

bondingnetworkofbuildings.

Verticalriser(VR)

2.0.38

Itisagroupofverticalconductorsprovidingalowresistanceengineeringpathbetweenthe

-

telecommunicationequipmentandmainearthingterminals,whichrunthroughverticallytheearthing

trunklinesateachflooroftelecommunicationbureaus(stations).

Lightningovervoltage

2.0.39-

Itisthetransientovervoltageoccurringatsystemports,whichiscausedbylightningdischarge.

Surgeprotectivedevices(SPD)

2.0.40

SPDsaredevicesusedtoprotectvarioustelecommunicationsystemsattelecommunication

bureaus(stations)incaseoflightningovervoltageoroperationovervoltage.

--

VoltagelimitingtypeSPD

2.0.41

Ingeneral,thevoltagelimitingtypeSPDiscomprisedofmetaloxidevaristorsorsemiconductor

protectiondevices,whichmustbeusedintelecommunicationbureaus(stations).

Maximumcontinuousoperatingvoltage

2.0.42

Itistheallowablemaximumalternatingvoltage(rms)ordirectvoltagepermanentlyappliedto

SPD.Thevaluethereofisequaltotheratedvoltage.

Residualvoltage

2.0.43

ItisthevoltagepeakbetweenterminalswhenthedischargecurrentflowsthroughSPD.

ResidualvoltageofSPD專用

2.0.44

ItisthemaximumvoltagepeakmeasuredbetweenSPDterminals,whenthesurgevoltagewith

specificwaveformandamplitudeisapplied.

Nominalstartupvoltage

2.0.45-

Itisthestartingvoltageofmetaloxidevaristor,whenaconstant1mAdirectcurrentisapplied.

Nominaldischargecurrent(In)

2.0.46

ItindicatestheindexofSPDdischargecapability,correspondingtothesurgecurrentof8/20μs

simulatedlightningwave.

Maximumdischargecurrent(Imax)

2.0.47

SPDwillnotbesubstantiallydamaged,andeachline(singlemodule)canpassthroughthe

maximumcurrentpeakwithspe

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

評論

0/150

提交評論