【BS英國標(biāo)準(zhǔn)】BS EN 61169-24-2002 射頻連接器.第24部分分規(guī)范.主要用于75歐姆電纜分布系統(tǒng)的螺紋連接射頻同軸連接器(F型).doc_第1頁
【BS英國標(biāo)準(zhǔn)】BS EN 61169-24-2002 射頻連接器.第24部分分規(guī)范.主要用于75歐姆電纜分布系統(tǒng)的螺紋連接射頻同軸連接器(F型).doc_第2頁
【BS英國標(biāo)準(zhǔn)】BS EN 61169-24-2002 射頻連接器.第24部分分規(guī)范.主要用于75歐姆電纜分布系統(tǒng)的螺紋連接射頻同軸連接器(F型).doc_第3頁
【BS英國標(biāo)準(zhǔn)】BS EN 61169-24-2002 射頻連接器.第24部分分規(guī)范.主要用于75歐姆電纜分布系統(tǒng)的螺紋連接射頻同軸連接器(F型).doc_第4頁
【BS英國標(biāo)準(zhǔn)】BS EN 61169-24-2002 射頻連接器.第24部分分規(guī)范.主要用于75歐姆電纜分布系統(tǒng)的螺紋連接射頻同軸連接器(F型).doc_第5頁
已閱讀5頁,還剩7頁未讀 繼續(xù)免費閱讀

下載本文檔

版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進行舉報或認領(lǐng)

文檔簡介

licensed copy: aub user, na, thu sep 20 10:22:41 gmt+00:00 2007, uncontrolled copy, (c) bsibritish standard bs en61169-24:2002iec61169-24:2001radio-frequency connectors part 24: sectional specification radio frequency coaxial connectors with screw coupling, typically for use in 75 ohm cable distribution systems (type f)the european standard en 61169-24:2001 has the status of abritish standardics 29.120.20; 33.120.30no copying without bsi permission except as permitted by copyright lawbs en 61169-24:2002national forewordthis british standard is the official english language version ofen 61169-24:2001. i t is identical with iec 61169-24:2001.the uk participation in its preparation was entrusted by technical committee epl/46, cables, wires, waveguides, rf connectors and accessories for communication and signalling, to subcommittee epl/46/2, rf connectors and waveguides, which has the responsibility to:aid enquirers to understand the text;present to the responsible international/european committee any enquiries on the interpretation, or proposals for change, and keep the uk interests informed;monitor related international and european developments and promulgate them in the uk.a list of organizations represented on this subcommittee can be obtained on request to its secretary.from 1 january 1997, all iec publications have the number 60000 added to the old number. for instance, iec 27-1 has been renumbered as iec 60027-1. for a period of time during the change over from one numbering system to the other, publications may contain identifiers from both systems.cross-referencesthe british standards which implement international or european publications referred to in this document may be found in the bsi standards catalogue under the section entitled “international standards correspondence index”, or by using the “find” facility of the bsi standards electronic catalogue.a british standard does not purport to include all the necessary provisions of a contract. users of british standards are responsible for their correct application.compliance with a british standard does not of itself confer immunity from legal obligations.licensed copy: aub user, na, thu sep 20 10:22:41 gmt+00:00 2007, uncontrolled copy, (c) bsithis british standard, having been prepared under the direction of the electrotechnical sector policy and strategy committee, was published under the authority of the standards policy and strategy committee on13 february 2002 bsi 13 february 2002isbn 0 580 38972 3summary of pagesthis document comprises a front cover, an inside front cover, the en title page,pages 2 to 18, an inside back cover and a back cover.the bsi copyright date displayed in this document indicates when the document was last issued.amd. no.datecommentsamendments issued since publicationeuropean standarden 61169-24norme europenneeuropische normdecember 2001ics 31.220.10english versionradio-frequency connectorspart 24: sectional specification -radio frequency coaxial connectors with screw coupling, typically for use in 75 ohm cable distribution systems (type f)(iec 61169-24:2001)connecteurs pour frquences radiolectriquespartie 24: spcification intermdiaire - connecteurs coaxiaux pour frquences radiolectriques avec couplage viss, spcifiquement utiliss dans les systmes de distribution des cbles 75 ohm(srie f)(cei 61169-24:2001)hochfrequenz-steckverbinderteil 24 rahmenspezifikation -koaxiale hochfrequenzsteckverbinder mit schraubkupplung, vorzugsweise fr den einsatz in 75 ohm kabelverteilnetzen (typ f)(iec 61169-24:2001)licensed copy: aub user, na, thu sep 20 10:22:41 gmt+00:00 2007, uncontrolled copy, (c) bsithis european standard was approved by cenelec on 2001-12-01. cenelec members are bound to comply with the cen/cenelec internal regulations which stipulate the conditions for giving this european standard the status of a national standard without any alteration.up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the central secretariat or to any cenelec member.this european standard exists in three official versions (english, french, german). a version in any other language made by translation under the responsibility of a cenelec member into its own language and notified to the central secretariat has the same status as the official versions.cenelec members are the national electrotechnical committees of austria, belgium, czech republic, denmark, finland, france, germany, greece, iceland, ireland, italy, luxembourg, malta, netherlands, norway, portugal, spain, sweden, switzerland and united kingdom.ceneleceuropean committee for electrotechnical standardization comit europen de normalisation electrotechnique europisches komitee fr elektrotechnische normungcentral secretariat: rue de stassart 35, b - 1050 brussels 2001 cenelec - all rights of exploitation in any form and by any means reserved worldwide for cenelec members.ref. no. en 61169-24:2001 epage 17en 6116924:2001licensed copy: aub user, na, thu sep 20 10:22:41 gmt+00:00 2007, uncontrolled copy, (c) bsiforewordthe text of document 46d/338/fdis, future edition 1 of iec 61169-24:2001, prepared by sc 46d, rf connectors, of iec tc 46, cables, wires, waveguides, rf connectors, and accessories for communication and signalling, was submitted to the iec-cenelec parallel vote and was approved by cenelec as en 61169-24 on 2001-12-01.the following dates were fixed: latest date by which the en has to be implemented at national level by publication of an identicalnational standard or by endorsement(dop) 2002-09-01 latest date by which the national standards conflictingwith the en have to be withdrawn(dow) 2004-12-01annexes designated normative are part of the body of the standard. in this standard, annex za is normativeannex za has been added by cenelec.endorsement noticethe text of the international standard iec 61169-24:2001 was approved by cenelec as a europeanstandard without any modification. bsi 13 february 2002licensed copy: aub user, na, thu sep 20 10:22:41 gmt+00:00 2007, uncontrolled copy, (c) bsicontents1scope . 42normative reference . 43interface dimensions . 43.1dimensions . 43.2mechanical gauges . 74quality assessment procedures. 74.1general . 74.2ratings and characteristics . 74.3test shedule and ispection requirements . 94.4procedures . 105instructions for preparation of detail specifications . 115.1general . 115.2identification of the detail specification . 115.3identification of the component . 115.4performance . 125.5marking, ordering information and related matters . 125.6selection of tests, test conditions and severities. 125.7blank detail specification pro-forma for type f connector . 13annex za (normative) normative references to international publications with theircorresponding european publications . 18licensed copy: aub user, na, thu sep 20 10:22:41 gmt+00:00 2007, uncontrolled copy, (c) bsiradio-frequency connectors part 24: sectional specification radio frequency coaxial connectors with screw coupling, typically for use in 75 ohm cable distribution systems (type f)1scopethis part of iec 61169, which is a sectional specification (ss), provides information and rules for the preparation of detail specifications (ds) for rf coaxial connectors with screw coupling, typically for use in 75 cable distribution systems (type f).it describes the interface dimensions for general purpose grade 2 connectors, dimensional details for standard test connectors, grade 0, together with gauging information and the mandatory tests selected from iec 61169-1, applicable to all ds relating to type f connectors.this specification indicates the recommended performance characteristics to be considered when writing a ds and covers test schedules and inspection requirements.2normative referencesthe following referenced documents are indispensable for the application of this document. for dated references, only the edition cited applies. for undated references, the latest edition of the referenced document (including any amendments) applies.iec 61169-1:1992, radio-frequency connectors part 1: generic specification general requirements and measuring methods3interface dimensions3.1dimensionsmillimetres are original dimensions.all undimensioned pictorial configurations are for reference purposes only.licensed copy: aub user, na, thu sep 20 10:22:41 gmt+00:00 2007, uncontrolled copy, (c) bsi3.1.1connector with pin centre contactiec 2204/01for notes 1, 2 and 3, see next page.referencemminmin.max.min.max.a b c d e f4,950,516,867,290,251,6312,953,80,1950,0200,2700,2870,0100,0640,5100,149figure 1 connector with pin centre contactlicensed copy: aub user, na, thu sep 20 10:22:41 gmt+00:00 2007, uncontrolled copy, (c) bsi3.1.2connector with socket centre contactiec 2205/01referencemminmin.max.min.max.g h ij k lm3,860,305,567,07,594,700,1520,0120,2190,2730,2990,185figure 2 connector with socket centre contactnotes relative to figures 1 and 2note 1 protrusion of the dielectric beyond the reference plane is applicable only to the 0,146 in nominal dielectric core diameter cables. w hen larger core diameter cables are used, no protrusion of the dielectric beyond the reference plane is permitted.note 2 shape of coupling nut is optional; however, provision for wrench tightening should be made. for example, wrench flats.note 3 applicable only to the 0,146 in nominal dielectric core diameter cables. the 3,8 mm maximum diameter is not applicable when larger core diameter cables are used.note 4 length of full thread.note 5 shape of connector body is optional; however, provision for wrench tightening should be made. for example, wrench flats.note 6 socket contact accepts a pin contact of 0,51 mm to 1,63 mm (0,020 in to 0,064 in); this will be satisfied at dimension m.3.2mechanical gaugesmillimetres are original dimensions.0all undimensioned pictorial configurations are for reference purposes only.r0,5 a00,1licensed copy: aub user, na, thu sep 20 10:22:41 gmt+00:00 2007, uncontrolled copy, (c) bsi8 +0,2iec 2206/01referencegauge cmmgauge dmmmin.max.min.max. a2,1002,1200,5700,580figure 3 gauge pins for centre contact of socket connectortest sequencea) steel test pin (c) (figure 3) shall be inserted once into the centre contact. b) a second steel test pin (d) (figure 3) shall be inserted into the centre contact.this gauge when in a vertical downward attitude shall be retained by the contact. this gauge will have a mass (weight) of 0,30 n.4quality assessment procedures4.1generalthe following subclauses provide recommended ratings, performance and test conditions to be considered when writing a detail specification (ds). they also provide an appropriate schedule of tests with minimum levels of conformance inspection.4.2ratings and characteristicsthe rf connectors defined in this standard are designed for use with a variety of flexible and semi-rigid coaxial cables and in microwave integrated circuits and similar uncabled applications.licensed copy: aub user, na, thu sep 20 10:22:41 gmt+00:00 2007, uncontrolled copy, (c) bsiratings and characteristicsiec 61169-1subclausevalueremarksincluding any deviations from standard test methodselectricalnominal impedancefrequency rangereflection factor- straight styles - right angle styles- solder bucket and pcb mounting stylecentre contact resistance- initial- after conditioningouter conductor continuity- initial- after conditioninginsulation resistance- initial- after conditioningproof voltage at sea level + screening effectivenessdischarge test (corona)...90-2 ghz7 % 5 m 10 m 2,5 m 1 m 750 vas 90 dbnashall meet the requirements of of iec 61169-1 when terminating a zc = 75 cablesee dssee dsunder consideration86-106 kpaztmechanicalgauge retention force (resilient contacts) contact captivation axial force torqueengagement and separationcoupling torque friction coupling proofmechanical tests on cable cable pulling cable torsiontensile strength of coupling mechanismbending moment...119.3.1230 nna0,066 nm max.0,46-0,69 nm1,7 nm120 n0,1 nm300 n2 nmsee 3.2 of iec 61169-1captivated contacts onlyscrew coupling connectorsto overcome friction of a coupling nutrelative to reference planeenvironmentalvibrationclimatic sequencesealingsalt mist..698 m/s10-500 hz40/70/211 cm3 /h max.48 h10 g acceleration100-110 kpa pressureendurancemechanicalhigh temperature9.59.61 000 cycles1 000 hnotes these values apply to basic connectors. they depend on the cable used. relevant values are given in the ds.+ voltage values are r.m.s. values at 50-60 hz, unless otherwise specified.# cables used with these connectors may have values of lower performance than those given in this table.licensed copy: aub user, na, thu sep 20 10:22:41 gmt+00:00 2007, uncontrolled copy, (c) bsi4.3test schedule and inspection requirements4.3.1acceptance testsnote for details of symbols, abbreviations and procedures, see 4.4.2.test method iec61169-1subclauseassessment level m (higher)assessment level h (lower)testrequiredilaql %periodtestrequiredilaql %periodgroup a1visual examination9.1.2aii1,0as31,5group b1outline dimensionsmechanical compatibilityengagement and separationgauge retention (resilient contact)sealing, non-hermetic sealing, hermetic voltage proofsolderability piece partsinsulation resistance...5a a a iaia ia a ia as4ii s4iiii ii s4s4s40,41,00,401,00,650,0150,400,400,40lotby lota a a iaia ia a ia as3s3s3s3s3s3ii s3s34,01,51,51,51,00,0254,04,04,0lotby lot4.3.2periodic teststhere are no group c tests for levels h and m.note for details of symbols, abbreviations and procedures, see 4.4.2.test methodiec 61169-1subclauseassessment level m (higher)assessment level h (lower)testrequirednumber of specimenspermittedfailures per groupperiodtestrequirednumber of specimenspermittedfailures per groupperiodgroup d1 (d)soldera

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

評論

0/150

提交評論