1、quarter 1part iii: quarterly check item/第三部分:季度檢查表quarterly checklist for fire fighting system消防系統(tǒng)季度檢查表noitem/檢查項目inspection results 檢查結(jié)果note/備注fire alarming system/火災自動報警系統(tǒng)fire detectors/火災探測器1if voltage is 24v工作電壓是否正常(24v)2installation angle < 45° 安裝角度小于45°3good contact with foundatio
2、n 和底座接觸良好4surface clean and not obstructed 表面清潔,未被阻擋5no obstructions in 0.5m 在0.5m的范圍內(nèi)無障礙物6if power supply is ok 電源指示燈是否閃亮7alarm functional test 報警功能測試8signal transition and alarm function 信號傳輸及報警功能interaction control facilities/ 聯(lián)動控制設備1heat and smoke release system functional test (auto end manual
3、mode)防排煙設備功能測試(手動及自動)semi-yearly/每半 年2fire rolling shutter functional test (auto and manual mode)防火卷簾門功能測試(手動及自動)3no obstructions under fire rolling shutter 防火卷簾門下無障礙物4fire alarming system and emergency lighting system functional test火災事故廣播及事故照明系統(tǒng)功能測試(手動及 自動)5no obstructions to fire emergency lighti
4、ng system 在事故照明系統(tǒng)周圍沒有障礙物阻礙視線6signal transition and alarm function 信號傳輸以及報警功能測試yearly/每年fire incident communication/消防通訊設備1communication with central fire control panel 消控中心與各點通訊正常fire alarm button/手動報警按鈕1if fixed firmly/ 安裝是否牢固2if there is enough clearance 周圍繪否有足夠操作空間3any damage or broken 是否有破損4if q
5、uantity enough 數(shù)量是否足夠5alarm functional test 報警功能測試randomly pick 2 sets 任選兩組power supply system/供電系統(tǒng)1auto switch function test主、備電源自動切換裝置功能正常1 3 test 測試13次2backup power system recharging test 備用電源充放電試驗12 test 測試12次3conjunction box/ 接線盒4no loose connection/ 接線端子連接牢固5clean surface/ 表面清潔6no damage/ 無破損a
6、uto-switch function/ 自動切換功能1non fire fighting power shut off test 強制切斷非消防電源功能試驗fire alarm control panel/火災控制盤(柜)1no loose connection/ 接線端子連接牢固2clean surface/ 表面清潔3no damage/ 無破損4if there is enough clearance 周圍是否有足夠操作空間5if grounding well/ 是否有可靠接地6if fixed firmly/ 安裝是否牢固alarm valve station functional
7、test/ 報警閥組功能測試1water pressure (bar)/ 水壓(ba“meet design spec 符合設計要求2alarm functional test 水力警鈴報警性能3water flow indicator functional test 水流指示器功能測試4 r presser switch functional test壓力開關功能測試5fire pump start test/ 消防泵是否啟動> 5min 運轉(zhuǎn)大于5min6if pressure before and after valve balanced 閥站前后壓差是否平衡outdoor con
8、trol valve/室外控制閥門1in the correct open-close status 開關狀態(tài)止常2if valves were secured by chain or other devices 閥門是否被鎖鏈或其他裝置鎖定3lubricant oil/ 是否已添加潤滑油4housekeeping in valves wells 室外閥門井中是否有其他雜物5if valves were broken 閥門是否有破損indoor fire hydrant system/室內(nèi)消防栓系統(tǒng)1no missing components消火栓、水槍、水帶、消防水喉,墊圈是否齊全2no r
9、ust on surface/ 表面無銹蝕3no broken parts/ 外觀無損壞,4no malfunction on alarm control 報警控制線路無故障5lubricant oil/ 潤滑油已添加6pump could be start within 5min after fire alarm 5' 水泵在報警5分鐘之內(nèi)啟動fire hydrant system/室外消防栓系統(tǒng)1no obstruction around fire hydrant 消防栓周圍無雜物2no broken parts /消防栓外觀無損壞3feed pressure is ok/ 水壓符
10、合要求4no water leakage/ 消防栓不漏水malfunction elimination status/故障排除情況no.item description/悄況描述respon person 負責人completion date 完成日期inspected by/檢查人 : date/日期: reviewed by/審核人 °: date/ r 期: note/說明1 25% spot checks should be conducted every quarter, all fire detectors should be covered in a yearly ba
11、se每季度抽檢25%火災探測器,每年對所安裝的火災探測器檢杳一次2. visual inspection in case there is no safe access to fire detectors 在無安全通道的條件下,可采取目測檢查3 should be conducted in precondition of no significant adverse impact to normal production and no damage to tested equipments 應在對生產(chǎn)沒有不良影響和對設備沒有損壞的條件進行測試。4. both alarm and signal transmission function should be checked 警報以及信號傳輸功能檢查5. should be conducted in precondition of no damage to
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
- 4. 未經(jīng)權益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負責。
- 6. 下載文件中如有侵權或不適當內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 2024購銷合同錦集
- 2024鋼筋采購合同范本
- 2025年度離婚后房產(chǎn)共有權處理協(xié)議3篇
- 2024消防整改工程環(huán)保合規(guī)性審查及整改協(xié)議3篇
- 2024年高端餐飲經(jīng)營管理轉(zhuǎn)讓合同
- 2025年度生態(tài)農(nóng)業(yè)園區(qū)草坪除草與農(nóng)產(chǎn)品質(zhì)量安全合同3篇
- 2025年度綠色建筑節(jié)能改造補充施工合同范本3篇
- 2024年高端醫(yī)療服務合同的服務內(nèi)容
- 2025年度智慧能源管理系統(tǒng)承包經(jīng)營合同范本3篇
- 2024年高校畢業(yè)生就業(yè)協(xié)議
- 藥用植物學-課件
- SCA自動涂膠系統(tǒng)培訓講義課件
- 施工現(xiàn)場臨時建筑驗收表
- 皓月集團市場營銷策略研究
- 二次砌筑配管(JDG)技術交底
- 施工升降機定期檢驗原始記錄
- AI技術打造智能客服機器人
- 國貨彩瞳美妝化消費趨勢洞察報告
- 云南省就業(yè)創(chuàng)業(yè)失業(yè)登記申請表
- 油氣儲存企業(yè)安全風險評估指南(試行)
- UL_標準(1026)家用電器中文版本
評論
0/150
提交評論