磁敏感加權(quán)成像在檢測急性腦缺血出血性轉(zhuǎn)化中的應(yīng)用價值_第1頁
磁敏感加權(quán)成像在檢測急性腦缺血出血性轉(zhuǎn)化中的應(yīng)用價值_第2頁
磁敏感加權(quán)成像在檢測急性腦缺血出血性轉(zhuǎn)化中的應(yīng)用價值_第3頁
磁敏感加權(quán)成像在檢測急性腦缺血出血性轉(zhuǎn)化中的應(yīng)用價值_第4頁
全文預(yù)覽已結(jié)束

下載本文檔

版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進(jìn)行舉報或認(rèn)領(lǐng)

文檔簡介

1、磁敏感加權(quán)成像在檢測急性腦缺血出血性轉(zhuǎn)化中的應(yīng)用價值         11-04-20 14:40:00     作者:楊春 朱麗麗 徐凱    編輯:studa20【摘要】  目的 評價磁敏感加權(quán)成像在檢測急性腦缺血出血性轉(zhuǎn)化中的應(yīng)用價值。方法 采用GE 3.0 T MRI對36例經(jīng)溶栓治療的急性缺血性腦卒中患者行磁敏感加權(quán)成像(susceptility-weighted imaging, SWI)序列及常規(guī)T1增強序列,并

2、于一周內(nèi)復(fù)查常規(guī)MR T1序列。比較SWI及T1強化異常范圍與復(fù)查MR出血范圍的一致性。結(jié)果 發(fā)生出血性轉(zhuǎn)化的5例患者SWI及常規(guī)T1增強序列均有異常表現(xiàn),1例患者T1增強存在異常強化區(qū),復(fù)查MR未示明確出血灶。比較SWI異常區(qū)面積、常規(guī)T1增強異常區(qū)面積及復(fù)查常規(guī)MR T1出血面積,發(fā)現(xiàn)SWI異常區(qū)面積與復(fù)查常規(guī)MR T1出血面積符合率較高。結(jié)論 磁敏感加權(quán)成像檢測急性缺血性腦卒中患者出血性轉(zhuǎn)化的價值優(yōu)于常規(guī)T1增強掃描。 【關(guān)鍵詞】  腦缺血;腦出血;磁共振成像;溶栓    Abstract Objective  To investigat

3、e the value of susceptility-weighted imaging in the detection of intracerebral hemorrhage after acute ischemic stroking.Methods  SWI sequence and T1-weighted sequence were performed in 36 cases with intracerebral hemorrhage using GE 3.0 T MRI .And MR T1 sequence was performed within one week. A

4、bnormal area on SWI and T1-weighted and bleeding area on MR were compared .Results  5 patients who had intracerebral hemorrhage after thrombolysis therapy had abnormal signal on SWI and T1-weighted imaging while 1 patients with no intracerebral hemorrhage had abnormal signal on T1-enhanced imag

5、ing. Abnormal signal area on SWI was in accordance with bleeding area on the second MR T1 imaging. Conclusion Susceptility-weighted imaging is better than T1-enhanced imaging in the  detection of intracerebral hemorrhage after thrombolytic therapy.    Key words cerebral ischemia;

6、intracerebral hemorrhage;magnetic resonance imaging;thrombolysis    急性腦缺血發(fā)生后盡早應(yīng)用溶栓治療,可以使阻塞的血管再通,恢復(fù)腦的血流供應(yīng),緩解、減輕由于局部腦缺血造成的神經(jīng)功能損害,有效的改善缺血性腦卒中患者的預(yù)后,但同時有可能出現(xiàn)出血性轉(zhuǎn)化,溶栓治療后的這一嚴(yán)重并發(fā)癥影響著治療效果,影響了溶栓療法的臨床應(yīng)用。因此,正確檢測出血對于溶栓治療的效果及其安全有重要的意義1。    材料與方法    1.病例選擇  選擇自2007

7、年4月至2007年8月之間在我院行MR檢查的急性缺血性腦卒中患者36例,發(fā)病時間30 min-6h,其中男性21例,女性15例,年齡2080歲。36例患者均給予靜脈溶栓治療,5例發(fā)生出血性轉(zhuǎn)化,所有患者于溶栓后48h內(nèi)復(fù)查MR檢查,掃描序列包括常規(guī)T1、T2序列、磁敏感加權(quán)成像(susceptility-weighted imaging, SWI)序列及常規(guī)T1增強序列,并于一周內(nèi)復(fù)查MR常規(guī)序列。本研究于檢查前得到了所有納入對象或其法定監(jiān)護(hù)人的同意并簽署了知情同意書。    2.MR檢查方法  本研究采用GE Signa EXCITE 3.0 T MR

8、 全身成像系統(tǒng),并用最新的8通道頭線圈以提高信噪比。掃描參數(shù)如下:軸位T1 WI,T1FLAIR,TR 2480ms,TE 24ms,Ti 820ms,層厚 6mm,視野(FOV)24cm×24cm,矩陣320×256;T2WI,快速自旋回波(TSE),TR 4350ms,TE 120ms,層厚6mm,視野(FOV)24cm×24cm,矩陣320×256;SWI,3D fSPGR,TR 30ms,TE 15ms,翻轉(zhuǎn)角20°,視野(FOV)24cm×24cm,矩陣512×448。SWI序列掃描完成后原始圖像傳到adw4.2工

9、作站處理,合成SWI圖,層厚6mm。T1增強掃描使用釓噴替酸葡甲胺(Gd-DTPA),0.1mmol/kg團(tuán)注后行軸位掃描。    Abstract     Objective   To   investigate the value of susceptility-weighted imaging in the detection of intracerebral hemorrhage after acute ischemic stroking.   Method

10、s   SWI sequence and T1-weighted sequence were performed in 36 cases with intracerebral hemorrhage using GE 3.0 T MRI .And MR T1 sequence was performed within one week. Abnormal area on SWI and T1-weighted and bleeding area on MR were compared.   Results   5 patients wh

11、o had intracerebral hemorrhage after thrombolysis therapy had abnormal signal on SWI and T1-weighted imaging while 1 patients with no intracerebral hemorrhage had abnormal signal on T1-enhanced imaging. Abnormal signal area on SWI was in accordance with bleeding area on the second MR T1 imaging.

12、0; Conclusion Susceptility-weighted imaging is better than T1-enhanced imaging in the detection of intracerebral hemorrhage after thrombolytic therapy.    Key words cerebral ischemia;intracerebral hemorrhage;magnetic resonance imaging;thrombolysis       

13、急性腦缺血發(fā)生后盡早應(yīng)用溶栓治療,可以使阻塞的血管再通,恢復(fù)腦的血流供應(yīng),緩解、減輕由于局部腦缺血造成的神經(jīng)功能損害,有效的改善缺血性腦卒中患者的預(yù)后,但同時有可能出現(xiàn)出血性轉(zhuǎn)化,溶栓治療后的這一嚴(yán)重并發(fā)癥影響著治療效果,影響了溶栓療法的臨床應(yīng)用。因此,正確檢測出血對于溶栓治療的效果及其安全有重要的意義1。    材料與方法    1.病例選擇  選擇自2007年4月至2007年8月之間在我院行MR檢查的急性缺血性腦卒中患者36例,發(fā)病時間30 min-6h,其中男性21例,女性15例,年齡2080歲。36例患者均給予靜脈溶

14、栓治療,5例發(fā)生出血性轉(zhuǎn)化,所有患者于溶栓后48h內(nèi)復(fù)查MR檢查,掃描序列包括常規(guī)T1、T2序列、磁敏感加權(quán)成像(susceptility-weighted imaging, SWI)序列及常規(guī)T1增強序列,并于一周內(nèi)復(fù)查MR常規(guī)序列。本研究于檢查前得到了所有納入對象或其法定監(jiān)護(hù)人的同意并簽署了知情同意書。    2.MR檢查方法  本研究采用GE Signa EXCITE 3.0 T MR 全身成像系統(tǒng),并用最新的8通道頭線圈以提高信噪比。掃描參數(shù)如下:軸位T1 WI,T1FLAIR,TR 2480ms,TE 24ms,Ti 820ms,層厚 6mm,

15、視野(FOV)24cm×24cm,矩陣320×256;T2WI,快速自旋回波(TSE),TR 4350ms,TE 120ms,層厚6mm,視野(FOV)24cm×24cm,矩陣320×256;SWI,3D fSPGR,TR 30ms,TE 15ms,翻轉(zhuǎn)角20°,視野(FOV)24cm×24cm,矩陣512×448。SWI序列掃描完成后原始圖像傳到adw4.2工作站處理,合成SWI圖,層厚6mm。T1增強掃描使用釓噴替酸葡甲胺(Gd-DTPA),0.1mmol/kg團(tuán)注后行軸位掃描。    3.

16、MR分析  為確保讀片的準(zhǔn)確性,所有MR結(jié)果均由一名神經(jīng)科醫(yī)生及一名放射科醫(yī)生采用盲法獨立分析。    結(jié)     果    36患者中,5例患者SWI圖像上可見異常低信號區(qū)、T1增強圖像上可見異常強化區(qū),復(fù)查MR上可見與梗塞區(qū)較一致的出血性轉(zhuǎn)化區(qū)域(圖1-3),30例患者SWI圖像上無異常低信號區(qū),T1 增強圖像上亦無異常強化區(qū),復(fù)查MR無出血性轉(zhuǎn)化區(qū),僅見腦梗塞區(qū);1例患者SWI圖像上無異常低信號區(qū),但T1 增強圖像上可見異常強化區(qū),復(fù)查MR無出血性轉(zhuǎn)化區(qū),僅見腦梗塞區(qū)。所有MR結(jié)果以復(fù)查MR為準(zhǔn),選擇出血面積最大層面,分別測定SWI、常規(guī)T1增強及復(fù)查MR 常規(guī)T1圖像上的異常區(qū)面積(表1)。比較SWI異常區(qū)面積、常規(guī)T1增強異常區(qū)面積及復(fù)查常規(guī)MR T1出血面積發(fā)現(xiàn)SWI異常區(qū)面積與復(fù)查常規(guī)MR T1出血面積符合率較高。    討     論    1.SWI序列基本原理  SWI是一組利用組織磁敏感性不同而成像的技術(shù)2,本文所指的SWI是一種全新的長回波時間、三個方向上均有流動補償?shù)奶荻然夭ㄐ蛄?,與傳統(tǒng)的T2*加權(quán)序列比較,具有

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

評論

0/150

提交評論