1、實(shí)用標(biāo)準(zhǔn)文檔通風(fēng)排煙設(shè)計(jì)工具箱通風(fēng)管道流量阻力表1、縮伸軟管摩擦阻力表圓形風(fēng)管v=2 m/sv=3 m/sv=4 m/sv=5 m/sv=6 m/s150127/0.43190/0.98254/1.8318/3.23381/4.46200226/0.32339/0.73452/1.30565/2.03678/2.92250353/0.26530/0.558707/1.04883/1.621060/2.33300509/0.21764/0.951018/1.621273/2.441521/3.582、鍍鋅板風(fēng)管摩擦阻力表矩型風(fēng)管風(fēng)量(m3/h)/摩擦阻力(Pa)mmv=2m/sv=3 m/sv=
2、4 m/sv=5 m/sv=6 m/s120 x120104/0.61156/1.27207/2.15259/3.25311/14.57160 x120138/0.51207/1.07277/1.8346/2.75415/3.86160 x160184/0.42277/0.78369/1.49461/2.26553/3.17200 x120173/0.46259/0.95346/1.62432/2.45734/3.44200 x160230/0.36346/0.77461/1.3576/1.79691/2.78250 x120216/0.41324/0.87432/1.47540/2.2364
3、8/250 x160288/0.32432/0.69576/1.17720/1.77864/2.48250 x200360/0.27540/0.58720/0.99900/1.501080/2.11320 x120269/0.38403/0.79537/1.34672/2.03806/2.86320 x160369/0.29553/0.61737/1.04922/1.581106/2.22320 x200461/0.25691/0.519221/0.871152/1.311382/1.85320 x250576/0.21864/0.431152/0.741440/1.121728/1.5740
4、0 x120336/0.35504/0.74673/1.25841/1.901009/2.67400 x160461/0.27691/0.56922/0.951152/1.451382/2.03400 x200576/0.22864/0.461152/0.781440/1.201728/1.68400 x250720/0.191080/0.381440/0.661800/1.002160/1.40500 x160576/ 0.25864/0.521152/0.891440/1.341728/1.89500 x200720/0.211080/0.421440/0.731800/1.12160/1
5、.54文案大全實(shí)用標(biāo)準(zhǔn)文檔500 x250900/0.171350/0.351800/0.602250/0.902700/1.28500 x3201152/0.141728/0.282304/0.492880/0.753456/1.05500 x4001440/0.122160/0.252880/0.423600/0.644320/0.89630 x160726/0.221089/0.481452/0.841814/1.122177/1.98630 x200907/0.191361/0.391814/0.672268/1.022722/1.43630 x2501134/0.161701/0.3
6、22268/0.552835/0.833402/0.19630 x3201452/0.132177/0.262903/0.443629/0.674355/0.94630 x4001814/0.112722/0.223629/0.374536/0.565443/0.79630 x5002268/0.13402/0.194536/0.315670/0.486804/0.68800 x160922/0.201382/0.421843/0.672304/1.022765/2.15800 x2001152/0.181728/0.372304/0.632880/0.953456/1.34800 x2501
7、440/0.142160/0.32880/0.513600/0.774320/1.08800 x3201843/0.12765/0.233686/0.404608/0.605530/0.851000 x2001440/0.162160/0.352880/0.603600/0.904320/1.301000 x2501800/0.132700/0.283600/0.484500/0.725400/1.021000 x3202304/0.113456/0.234608/0.375760/0.576912/0.80圓形風(fēng)管v=2 m/sv=3 m/sv=4 m/sv=5 m/sv=6 m/s1005
8、5/0.7683/1.58111/2.68139/4.05166/5.69140109/0.49164/1.03219/1.75273/2.64328/3.72200224/0.31336/0.66448/1.12560/1.69672/2.382503.49/0.24524/0.5698/0.85873/1.281048/1.80360727/0.151090/0.321454/0.541817/0.822180/1.15400898/0.131347/0.281796/0.472245/0.722694/1.015001405/0.12108/0.212811/0.363513/0.554
9、216/0.77說(shuō)明(1),軟管采用荷蘭數(shù)據(jù)時(shí),上述數(shù)據(jù)乘以下系數(shù):150 x2;200 x1.8 ; 250 x1.5 ; 300 x1.3(2),局部摩擦阻力:散流器喉徑(mm) P (Pa)v=2m/sv=3 m/sv=4 m/sv=5 m/sv=6m/s200 x20015.935.763.499.1142.7300 x30023.853.595.1148.7214.1400 x40029.466.0117.3183.2263.9(3)與散流器的摩擦阻力:文案大全實(shí)用標(biāo)準(zhǔn)文檔接管規(guī)格 P (Pa)(mm)v=2m/sv=3 m/sv=4 m/sv=5 m/sv=6m/s鍍鋅管200 x
10、2002.45.39.414.721.2鍍鋅管400 x4006.414.3225.539.857.3軟管15010.822.328.841.354.1軟管35010.122.740.463.190.8(4),保持風(fēng)速必須的動(dòng)壓:當(dāng) v=2m/s時(shí), P=2.4Pa;當(dāng) v=3m/s 時(shí), P=5.4Pa當(dāng) v=4m/s時(shí), P=9.6Pa;當(dāng) v=5m/s 時(shí), P=15Pa當(dāng) v=6m/s時(shí), P=21PaV2(5).其他局部阻力的計(jì)算按下式2g P二 ( T:、室內(nèi)送回風(fēng)口尺寸表1、風(fēng)口風(fēng)量冷量對(duì)應(yīng)表冷量風(fēng)量送風(fēng)口回風(fēng)口RTkwm/hmmmm1.03.5750700 x150800 x1
11、501.55.3800700 x150800 x1502.071000900 x1501000 x150/800 x2002.58.714501000 x2001200 x2003.010.516001100 x2001300 x2003.512.218001250 x200/1000 x2501500 x200/1200 x2504.01419501000 x2501300 x2505.017.5830001600 x250/1360 x3002、不同送風(fēng)方式的風(fēng)量指標(biāo)和室內(nèi)平均流速ASHRAE文案大全實(shí)用標(biāo)準(zhǔn)文檔送風(fēng)方式單位地板面積的送風(fēng)量l/sm 2工作區(qū)平均流速m/s換氣次數(shù)h-1側(cè)送
12、百葉風(fēng)口3-60.13-0.187條形風(fēng)口4-100.10-0.1812局部孔板送風(fēng)5-150.10-0.1818頂棚散流器5-250.10-0.2530頂棚孔板送風(fēng)5-500.05-0.1560、室內(nèi)風(fēng)管風(fēng)速選擇表1、低速風(fēng)管系統(tǒng)的推薦和最大流速m/s應(yīng)用場(chǎng)所住宅公共建筑工廠推薦最大推薦最大推薦最大室外空氣入口2.54.02.54.52.58.0空氣過(guò)濾器1.31.51.51.81.81.8加熱排管2.32.52.53.03.03.5冷卻排管2.32.32.52.53.03.0淋水室2.52.52.52.52.52.5風(fēng)機(jī)出口6.08.59.011.010.014.0主風(fēng)管4.06.06.0
13、8.09.011.0支風(fēng)管(水平)3.05.04.06.55.09.0支風(fēng)管(垂直)2.54.03.56.04.08.02、低速風(fēng)管系統(tǒng)的最大允許速m/s應(yīng)用場(chǎng)所以噪聲控制 主風(fēng)管以摩擦阻力控制送風(fēng)主管回風(fēng)主管送風(fēng)支管回風(fēng)支管住宅公寓、飯店房間3.05.04.03.03.0辦公室、圖書(shū)館5.07.56.56.05.0大禮堂、戲院6.010.07.58.06.1銀行、高級(jí)餐廳4.06.55.55.04.0百貨店、自助餐7.510.07.58.06.0廳9.012.07.58.06.0工廠12.515.09.011.07.53、通風(fēng)系統(tǒng)之流速m/s系統(tǒng)商業(yè)工業(yè)文案大全實(shí)用標(biāo)準(zhǔn)文檔低送風(fēng)、最大流速1
14、313送風(fēng)、一般流速6-1111-13速回風(fēng)、最大流速1013回風(fēng)、一般流速7.5-99-13高速、一般1313-25室內(nèi)允許噪聲主管風(fēng)速支管風(fēng)速dB (A)m/sm/s25-353-447、百葉窗的推薦流速m/s位置新風(fēng)回風(fēng)減溫器正面減溫器旁通加熱器旁通流速m/s2.5-44-62-47.5-125-7.58、逗留區(qū)流速與人體感覺(jué)的關(guān)系文案大全實(shí)用標(biāo)準(zhǔn)文檔流速m/s人體感覺(jué)-0-0.08不舒適,停滯空氣的感覺(jué)0.127理想,舒適0.127-0.25基本舒適0.38不舒適,可以吹動(dòng)薄紙0.38對(duì)站立者為舒適感之上限0.38-1.52用于工廠和局部空間9、頂棚散流器送風(fēng)量尺寸mm送風(fēng)流速m/s1
15、.01.52.02.53.755.0250*250507095120175235300*30070100135170255340350*35090140185230350465400*400120180240295440590500*500190280380470710945600*6002704105456801020136010、側(cè)送風(fēng)口送風(fēng)量送風(fēng)口尺寸mm送風(fēng)口流速m/s1.52.02.53.755.0250*1003040507095300*10035455585115400*100456075115150500*100557595145190600*10070901151702307
16、50*10085115145215285900*100100135170255340250*150455570105145300*150507085130170400*1507090115170230500*15085115145215285600*150100135170255340750*150130170215320430900*150155205255385515文案大全實(shí)用標(biāo)準(zhǔn)文檔400*20090120150230305500*200115150190285380600*200135180230340455750*200170230285430570900*200205275340
17、415685400*250115150190285380500*250145190240355475600*250170230285430570750*250215285355535715900*2502553404306408551000*505575951451901000*75851151452152851000*1001151501902853801000*1251451902403554751000*150170230285430570&, lt;, /DIV1000*1752002653305006651000*200230305380570760五、通風(fēng)系統(tǒng)設(shè)計(jì)1、送風(fēng)口布置間距
18、辦 公 室2.5-3.5m商場(chǎng)、娛樂(lè)114-6m回風(fēng)口應(yīng)根據(jù)具體情況布置一般原則:(1)人不經(jīng)常停留的地方;(2)房間的邊和角;(3)有利于氣流的組織。2、標(biāo)準(zhǔn)型號(hào)風(fēng)盤(pán)所接散流器的尺寸表-辦公室風(fēng)盤(pán)型號(hào)風(fēng)量方散尺寸FPm3/hmm3.5350200*2005500200*2006.3630250*2508800250*250101000300*300文案大全實(shí)用標(biāo)準(zhǔn)文檔12.5162025注:辦公室推薦送風(fēng)口流速:2.5-4.0m/s1250160025002500300*300350*350450*450450*450風(fēng)機(jī)盤(pán)管接風(fēng)管的風(fēng)速:通常為1.52.0m/s之間,不能大于2.5m/s
19、,否則會(huì)將冷凝水帶出來(lái)3、散流器布置散流器平送時(shí),宜按對(duì)稱布置或者梅花型布置,散流器中心與側(cè)墻的距離不宜小于1000mm圓形或方形散流器布置時(shí),其相應(yīng)送風(fēng)范圍(面積)的長(zhǎng)寬比不宜大于1 : 1.5 ,送風(fēng)水平射程與垂直射程(平頂至工作區(qū)上邊界的距離)的比值,宜保持在0.51.5之間。實(shí)際上這要看裝飾要求而定,如 250*250的散流器,間距一般在 3.5米左右,320*320在4.2米左右。4、空調(diào)房間允許最大送風(fēng)溫差C送風(fēng)方式下列房間高度m23456側(cè)送、大風(fēng)量6.58.3101214側(cè)送、小風(fēng)量9.011131517頂棚散流器9.516171818舒適性空調(diào)的送風(fēng)溫差 送風(fēng)高度H小于等于5
20、m,送風(fēng)溫差小于等于 10度;送風(fēng)高度H大于5m,送風(fēng)溫差小于等于 15度。為防止出風(fēng)口結(jié)露,應(yīng)使送風(fēng)干球溫度高于室內(nèi)空氣的露點(diǎn)溫度2-3度。5、工藝性空氣調(diào)節(jié)空調(diào)房間允許最大送風(fēng)溫差室溫允許波動(dòng)范圍(oC)送風(fēng)溫差(oC) 1.0=15+ 1.0610+ 2.036+ 1.00.223注:生活區(qū)或工作區(qū)處于下送氣流的擴(kuò)散區(qū)時(shí) ,送風(fēng)溫差應(yīng)通過(guò)計(jì)算確定。文案大全實(shí)用標(biāo)準(zhǔn)文檔、廚房通風(fēng)問(wèn)題飲食建筑設(shè)計(jì)規(guī)范(JGJ64-89)對(duì)廚房操作間通風(fēng)彳了明確規(guī)定:(1)計(jì)算排風(fēng)量的65%S過(guò)排氣罩排至室外,而由房間的全面換氣排出35% (2)排氣罩口吸氣速度一般不應(yīng)小于0.5 m/s,排風(fēng)管內(nèi)速度不應(yīng)小于
21、10 m/s ; (3)熱加工間補(bǔ)風(fēng)量宜為排風(fēng)量的70溢右,房間負(fù)壓值不應(yīng)大于5 Pa。然而,有的工程的廚房未設(shè)排氣罩,僅在外墻上設(shè)幾臺(tái)排氣扇;有的雖然設(shè)置了排氣罩,但罩口吸氣速度遠(yuǎn)小于0.5 m/s ,選配的排風(fēng)機(jī)風(fēng)量不足。大多工程未設(shè)置全面換氣裝置,亦未考慮補(bǔ)風(fēng)裝置,難以保證室內(nèi)衛(wèi)生環(huán)境要求及 負(fù)壓值要求。如何確定廚房的通風(fēng)量公共建筑中的廚房,是一個(gè)很重要的組成部分,但在設(shè)計(jì)上通常是一個(gè)薄弱環(huán)節(jié),一方面,在施工圖紙?jiān)O(shè) 計(jì)階段,往往得不到有關(guān)廚房的詳細(xì)工藝資料,在建筑專業(yè)所提供的方案圖上,一般只有廚房的面積、層 高和灶臺(tái)的位置,另一方面在現(xiàn)有的設(shè)計(jì)參考資料中缺少有針對(duì)性的技術(shù)措施,這就給合理
22、地確定廚房通 風(fēng)量帶來(lái)了困難,通常同樣的廚房,不同的人進(jìn)行設(shè)計(jì),其結(jié)果往往不同,甚至相差懸殊,但是依據(jù)技術(shù) 措施,又能各自找到根據(jù)。因此,廚房的通風(fēng)設(shè)計(jì)形成了,因人而異,無(wú)統(tǒng)一標(biāo)準(zhǔn)的局面,我認(rèn)為之所以 會(huì)出現(xiàn)這種現(xiàn)象,與我們常用的技術(shù)措施在廚房通風(fēng)量確定上,概念不明確,要求不一致有關(guān),為說(shuō) 明問(wèn)題,我們可以結(jié)合常用的建設(shè)部建筑設(shè)計(jì)院民用建筑暖通空調(diào)設(shè)計(jì)技術(shù)措施,(下簡(jiǎn)稱措施一)和我院編制的暖通專業(yè)統(tǒng)一技術(shù)措施(下簡(jiǎn)稱措施二)中的有關(guān)規(guī)定,討論一下廚房的通風(fēng)量確定問(wèn)題。措施一第 4-28條規(guī)定:機(jī)械通風(fēng)的換氣量宜按熱平衡計(jì)算,計(jì)算排風(fēng)量的65%通過(guò)排氣罩或屏幕等排除室外,而由房間的全面換氣排出3
23、5% 另外,在第4-26條中,已規(guī)定了排氣罩口的風(fēng)速應(yīng)控制在0.40.5m/s o措施二第5- 1-3條中規(guī)定:設(shè)有空調(diào)系統(tǒng)的廚房其機(jī)械通風(fēng)的換氣量,宜 按熱平衡及風(fēng)量平衡計(jì)算,當(dāng)熱平衡計(jì)算確有困難時(shí),可按下述兩種方法中的一種計(jì)算,并以第一種方法,為優(yōu)選方法。1. L1=1800 XF1 (F1為罩口面積) L2=10XF2 ( F2為廚房面積)L=L1+L2 ( L為總排氣 量)2.按6080次/時(shí)換氣計(jì)算,(廚房面積小于50 m2時(shí)取上限,大于50 m2時(shí)取下限)。廚房排風(fēng)中應(yīng)有相當(dāng)于35次/時(shí)換氣次數(shù)的風(fēng)量為全面換氣設(shè)備排出,但不計(jì)入總風(fēng)量。從措施一措施二的規(guī)定中,我們似乎得到一個(gè)左右廚房通風(fēng)量計(jì)算的一個(gè)概念。那就是,在廚房的排氣罩工作時(shí),還應(yīng)該 有其它的排風(fēng)機(jī)在同時(shí)工作,廚房?jī)?nèi)的排風(fēng)不能僅從排氣罩排出,而必須留有其它排風(fēng)出路,并且要有一 定的比例關(guān)系,或者占到全部排風(fēng)
溫馨提示
- 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 合伙入股合同范例
- 中廳拆除合同范例
- 德州購(gòu)房合同范例
- 裝潢材料合同范例
- 汕頭大學(xué)《食品添加劑線上線下》2023-2024學(xué)年第一學(xué)期期末試卷
- 陜西職業(yè)技術(shù)學(xué)院《水彩粉風(fēng)景寫(xiě)生》2023-2024學(xué)年第一學(xué)期期末試卷
- 2024至2030年角磨齒輪項(xiàng)目投資價(jià)值分析報(bào)告
- 搜索合作合同范例
- 2024至2030年潔凈操作臺(tái)項(xiàng)目投資價(jià)值分析報(bào)告
- 2024至2030年工業(yè)伺服系統(tǒng)項(xiàng)目投資價(jià)值分析報(bào)告
- 微型消防站火災(zāi)處理流程圖
- 高中語(yǔ)文 必修上 第七單元“自然情懷”單元 教學(xué)設(shè)計(jì) “天地大美生命超越”
- 新教材選擇性必修第二冊(cè)人教英語(yǔ)課文語(yǔ)法填空
- 卡簧規(guī)格尺寸WORD版
- 統(tǒng)計(jì)學(xué)專業(yè)經(jīng)典案例分析
- 電梯及電梯配件項(xiàng)目可行性研究報(bào)告寫(xiě)作范文
- 電鍍生產(chǎn)停電應(yīng)急程序
- 部編版(統(tǒng)編)小學(xué)語(yǔ)文三年級(jí)上冊(cè)期末試卷(含答題卡)
- 崗位標(biāo)準(zhǔn)之鐵路工務(wù)線路工崗位作業(yè)標(biāo)準(zhǔn)
- 一人一檔檔案模板
- 臨時(shí)豎井旋噴樁首件施工總結(jié)
評(píng)論
0/150
提交評(píng)論