




版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進行舉報或認領(lǐng)
文檔簡介
精編文檔/r/n精編文檔/r/n./r/n./r/n精編文檔/r/n./r/n施工組織設(shè)計/r/n〔機電安裝工程〕/r/n編制單位:/r/n國基建設(shè)集團/r/n編制人:/r/n機電工程部/r/n二O一五年/r/n十/r/n月/r/n二十/r/n日/r/n目錄/r/n/r/n/r/n/r/n/r/n第一章/r/n/r/n編制依據(jù)/r/n /r/n/r/n5/r/n/r/n/r/n/r/n第二章/r/n/r/n工程概況/r/n /r/n/r/n7/r/n/r/n/r/n/r/n第三章/r/n/r/n施工部署/r/n /r/n/r/n9/r/n/r/n/r/n/r/n〈一〉施工準備/r/n /r/n/r/n9/r/n/r/n/r/n/r/n〈二〉施工組織/r/n /r/n/r/n10/r/n/r/n/r/n/r/n〈三〉施工部署/r/n /r/n/r/n10/r/n/r/n/r/n/r/n〈四〉施工階段劃分/r/n /r/n/r/n12/r/n/r/n/r/n/r/n第四章/r/n/r/n主要分部、分項施工方案/r/n /r/n/r/n15/r/n/r/n/r/n/r/n一、電氣局部/r/n /r/n/r/n15/r/n/r/n/r/n/r/n〔一〕動力局部/r/n /r/n/r/n15/r/n/r/n/r/n/r/n〔二〕電氣照明局部/r/n /r/n/r/n32/r/n/r/n/r/n/r/n〔三〕消防報警、背景音樂及緊急播送系統(tǒng)/r/n /r/n/r/n35/r/n/r/n/r/n/r/n〔四〕防雷接地系統(tǒng)/r/n /r/n/r/n44/r/n/r/n/r/n/r/n二、給排水局部〔含消防給水、噴淋、泵房、太陽能熱水〕/r/n /r/n/r/n46/r/n/r/n/r/n/r/n1/r/n〕、施工范圍及流程:/r/n /r/n/r/n46/r/n/r/n/r/n/r/n2)/r/n、預(yù)留預(yù)埋及安裝/r/n /r/n/r/n60/r/n/r/n/r/n/r/n三、暖通系統(tǒng)/r/n /r/n/r/n75/r/n/r/n/r/n/r/n(/r/n一/r/n)/r/n施工劃分/r/n /r/n/r/n75/r/n/r/n/r/n/r/n〔二〕施工過程/r/n /r/n/r/n76/r/n/r/n/r/n/r/n第五章/r/n/r/n工程質(zhì)量保證措施/r/n /r/n/r/n109/r/n/r/n/r/n/r/n一、工程質(zhì)量保證措施/r/n /r/n/r/n109/r/n/r/n/r/n/r/n二、分項工程的質(zhì)量控制/r/n /r/n/r/n112/r/n/r/n/r/n/r/n三、施工過程的質(zhì)量保證/r/n /r/n/r/n113/r/n/r/n/r/n/r/n四、/r/n/r/n應(yīng)急預(yù)案/r/n /r/n/r/n122/r/n/r/n/r/n/r/n第六章/r/n/r/n平安管理、文明施工、環(huán)境保護/r/n /r/n/r/n124/r/n/r/n/r/n/r/n第一節(jié)、/r/n/r/n平安管理/r/n /r/n/r/n124/r/n/r/n/r/n/r/n第二節(jié)、文明施工/r/n /r/n/r/n134/r/n/r/n/r/n/r/n第三節(jié)、環(huán)境保護/r/n /r/n/r/n141/r/n/r/n/r/n/r/n第七章主要資源需用方案/r/n /r/n/r/n146/r/n/r/n/r/n/r/n一、勞動力配置方案及管理措施/r/n /r/n/r/n146/r/n/r/n/r/n/r/n二、施工機械配置方案及管理措施/r/n /r/n/r/n149/r/n/r/n/r/n/r/n第八章/r/n/r/n施工進度控制管理/r/n /r/n/r/n154/r/n/r/n/r/n/r/n第一節(jié)、工期目標/r/n /r/n/r/n154/r/n/r/n/r/n/r/n第二節(jié)、網(wǎng)絡(luò)進度方案圖/r/n /r/n/r/n154/r/n/r/n/r/n/r/n第三節(jié)、關(guān)鍵節(jié)點的控制措施/r/n /r/n/r/n154/r/n/r/n/r/n/r/n第四節(jié)、工期保證的組織措施/r/n /r/n/r/n155/r/n/r/n/r/n/r/n第五節(jié)、工期保證的其它措施/r/n /r/n/r/n156/r/n/r/n/r/n/r/n第六節(jié)、進度方案的檢查與監(jiān)督/r/n /r/n/r/n158/r/n/r/n/r/n/r/n第九章/r/n/r/n深化設(shè)計/r/n /r/n/r/n161/r/n/r/n/r/n/r/n第一節(jié)、深化設(shè)計原那么/r/n /r/n/r/n161/r/n/r/n/r/n/r/n第二節(jié)、深化設(shè)計的總體部署/r/n /r/n/r/n162/r/n/r/n/r/n/r/n第三節(jié)、深化設(shè)計管理流程圖/r/n /r/n/r/n163/r/n/r/n/r/n/r/n第四節(jié)、深化設(shè)計的主要工作內(nèi)容/r/n /r/n/r/n164/r/n/r/n/r/n/r/n第十章/r/n/r/n工程保修與效勞/r/n /r/n/r/n167/r/n/r/n/r/n/r/n第一節(jié)、工程交付:/r/n /r/n/r/n167/r/n/r/n/r/n/r/n第二節(jié)、/r/n/r/n工程保修/r/n /r/n/r/n167/r/n/r/n/r/n/r/n第三節(jié)、/r/n/r/n保修記錄:/r/n /r/n/r/n169/r/n第一章編制依據(jù)/r/n1.施工圖紙設(shè)計、圖紙設(shè)計有關(guān)說明、圖紙會審記錄。/r/n2.國家現(xiàn)行的技術(shù)政策、技術(shù)標準、/r/n?建筑安裝工程質(zhì)量檢驗評定統(tǒng)一標準?〔GB50300-2001〕/r/n?建筑電氣工程質(zhì)量驗收標準?〔GB50303-2002〕/r/n?消防設(shè)備電源監(jiān)控系統(tǒng)?〔GB28184-2021〕/r/n?建筑給水排水及采暖工程質(zhì)量驗收標準?〔GB50242-2002〕/r/n?防空地下室給排水設(shè)施安裝?〔07FS02〕/r/n?人民防空工程防護設(shè)備選用圖集?RFJ01-2021/r/n?民用建筑太陽能熱水系統(tǒng)應(yīng)用技術(shù)標準?〔GB50364-2005〕/r/n?城鎮(zhèn)給水排水技術(shù)標準?〔GB50788-2021〕/r/n?建筑給水鋼塑復(fù)合管管道工程技術(shù)規(guī)程?〔CECS125-2001〕/r/n?給水襯塑復(fù)合鋼管行業(yè)標準?〔CJ-T136-2007〕/r/n?建筑給水聚丙烯管道工程技術(shù)標準?〔GB/T50349-2005〕/r/n?建筑給水薄壁不銹鋼管管道工程技術(shù)規(guī)程?〔CECS153-2003〕/r/n?建筑排水柔性接口鑄鐵管管道工程技術(shù)規(guī)程?〔CECS168:2004〕/r/n?消防給水及消火栓系統(tǒng)技術(shù)標準?〔GB50974-2021〕/r/n?通風與空調(diào)工程施工質(zhì)量驗收標準?(GB50738-2021)/r/n?工業(yè)金屬管道工程施工質(zhì)量驗收標準?(GB50184-2021)/r/n?制冷設(shè)備、空氣別離設(shè)備安裝工程施工及驗收/r/n(GB50274-2021)/r/n?壓縮機、風機、泵安裝工程施工及驗收標準?(GB50275-2021)/r/n?工業(yè)設(shè)備及管道絕熱工程質(zhì)量檢驗評定標準?(GB50185-2021)/r/n?管道和設(shè)備保溫、防結(jié)露及電伴熱?〔03S401〕/r/n?建筑節(jié)能工程施工質(zhì)量驗收標準?(GB50144-2007)/r/n?現(xiàn)場設(shè)備、工業(yè)管道焊接工程施工驗收標準?(GB50236-2021)/r/n?通風管道技術(shù)規(guī)程?(JGJ141-2004J363-2021)/r/n?智能建筑工程施工質(zhì)量驗收標準?〔GB50339-2003〕/r/n?火災(zāi)自動報警系統(tǒng)施工驗收標準?〔GB50166-2007〕/r/n?防靜電工程技術(shù)標準?〔DGJ08-83-2000〕/r/n及其他相關(guān)國家及地方質(zhì)量標準要求。/r/n3.?工程建設(shè)標準強制性條文?。/r/n4.?工期定額?、?勞動定額?、?預(yù)算定額?及施工圖預(yù)算等。/r/n5.?現(xiàn)場文明施工管理條例?。/r/n6.我單位的有關(guān)質(zhì)量、平安的實施細那么和管理方法。/r/n7.其他未盡事宜詳見?施工組織設(shè)計?〔土建分冊〕。/r/n第二章/r/n工程概況/r/n第一節(jié)、參建單位/r/n工程名稱:/r/n沃爾瑪/r/n南昌樂世界購物中心/r/n建設(shè)單位:沃爾瑪亞洲房地產(chǎn)開發(fā)〔南昌〕/r/n設(shè)計單位:艾奕康建筑設(shè)計〔深圳〕/r/n監(jiān)理單位:南昌建筑技術(shù)咨詢監(jiān)理/r/n工程管理公司:艾奕康咨詢〔深圳〕上海分公司/r/n造價參謀公司:格利資工程咨詢〔上海〕/r/n第二節(jié)、工程概況/r/n本工程位于江西省南昌市紅谷灘新區(qū),豐和南大道以東,前湖大道以南。工程用地面積48199.05㎡,工程規(guī)劃占地面積22021.06㎡,總建筑面積為98211.13㎡。主建筑是地面三層鋼筋混凝土結(jié)構(gòu),二層地下室。建筑物高度23米。施工方案于2021年11月開工,2021年4月完工并開始營業(yè)。/r/n第三節(jié)、工程范圍/r/n包括但不限于圖紙、清單所示的全部暖通工程、機械電氣管道工程、給排水工程、消防工程、局部裝飾機電工程及停車場和室外機電工程。/r/n第四節(jié)、工程主要目標/r/n1)工程質(zhì)量到達國家施工驗收標準合格標準,并配合土建做好平安防護工作。/r/n2)文明施工承諾:本工程全面實行現(xiàn)場標準化管理。在施工期間無質(zhì)量事故及重大平安事故發(fā)生。/r/n3)/r/n本工程/r/n合同總工期為相應(yīng)合同規(guī)定日期,確保在業(yè)主要求日期內(nèi)全面完本錢工程合同內(nèi)的全部工程內(nèi)容。/r/n4)平安管理目標:重大環(huán)境事件、事故為零;輕傷事故頻率控制在0.5/r/n‰/r/n以內(nèi);杜絕火災(zāi)、設(shè)備、管線等重大事故。/r/n5〕平安創(chuàng)立目標:通過安保體系認證/r/n。/r/n6〕環(huán)境管理目標:沒有業(yè)主、社會相關(guān)方和員工的重大投訴;粉塵控制、污水排放、光污染、噪聲、固體廢棄外物到達城市管理要求/r/n7〕職業(yè)健康管理目標:無發(fā)生食物中毒等重大事故;無發(fā)生中暑事故;無發(fā)生傳染病事故/r/n8〕本錢目標:確保經(jīng)濟指標的考核要求。/r/n9〕管理目標:爭創(chuàng)學(xué)習型工程部,實現(xiàn)建樓育人,再塑國基建設(shè)的建筑豐碑。/r/n/r/n第三章施工部署/r/n〈一〉施工準備/r/n1、/r/n技術(shù)準備/r/n組織有關(guān)技術(shù)人員,施工人員熟悉圖紙,理解設(shè)計意圖,先進行圖紙自審,再與/r/n工程管理公司、設(shè)/r/n計單位/r/n、/r/n監(jiān)理單位做好圖紙會審工作。/r/n做好入場人員的教育,培訓(xùn)工作,及時編制專項施工技術(shù)和平安技術(shù)措施,并做好三級交底工作,使全體操作員明了工程特點,做到心中有數(shù),保證工程施工順利進行。/r/n2、本卷須知/r/n2.1本工程防空地下室平戰(zhàn)結(jié)合照明、動力配電及通風信號系統(tǒng)等的施工圖。人防電力系統(tǒng)第一電源位平戰(zhàn)結(jié)合常用電源。每個防護單元從本建筑物的變電所的應(yīng)急電源母線段引來一路電源。/r/n第二電源為戰(zhàn)時備用電源,引自本人防的固定電站。/r/n2.2/r/n設(shè)置在染毒區(qū)的進、排風管均為圓形風管,并采用3毫米厚的鋼板焊接成型,風管應(yīng)有0.005的坡度坡向室外。其余風管采用鍍鋅鋼板制作。穿過防護墻及防護密閉墻的風管〔含超壓排氣活門的穿墻管、測壓裝置的穿墻管等〕應(yīng)在穿墻管段上焊接密閉盤。/r/n3、/r/n物資資源準備/r/n1〕安裝庫房三間,工具房一間,保管員值班房一間,安裝加工棚四個,安裝大型材料堆放場一處。/r/n2〕/r/n安排好各種物資,資源的進場方案。主要有:主要設(shè)備需求方案,勞動力需求方案,各種材料半成品進場方案等。/r/n3〕/r/n根據(jù)施工進度方案編制材料現(xiàn)場庫存方案,供應(yīng)方案,確保按進度方案供應(yīng)。/r/n〈二〉施工組織/r/n1〕/r/n按照目標決定組織的原那么,組織精干有力的施工管理層和施工作業(yè)人員對本標段工程進行施工。/r/n2)/r/n建立精干/r/n、/r/n高效/r/n、/r/n政令和信息暢通的組織機構(gòu)。/r/n圍繞工程特點,采用先進而成熟的施工工藝/r/n、/r/n技術(shù)/r/n、/r/n設(shè)備/r/n,/r/n運用現(xiàn)代化的管理手段和方法,/r/n以質(zhì)量管理為中心,平安施工為保障,合理部署,科學(xué)施工,確保工程各控制目標的實現(xiàn)。/r/n本工程工程部組織機構(gòu)/r/n/r/n/r/n本標段工程安排一個標段工程經(jīng)理負責整個標段工程施工管理,本工程設(shè)一個工程經(jīng)理負責全面施工管理確保各項管理目標的實現(xiàn)。/r/n〈三〉施工部署/r/n1)/r/n安裝工程用水用電與土建合用。臨時配電及水管布置見/r/n“/r/n施工現(xiàn)場平面布置圖〞及/r/n“/r/n施工現(xiàn)場臨時用電平面布置圖〞。/r/n2)/r/n安裝工程包括電氣/r/n系統(tǒng)/r/n、/r/n生活給排水/r/n管道/r/n系統(tǒng)/r/n、/r/n暖通/r/n系統(tǒng)/r/n三/r/n個專業(yè)同時進行大規(guī)模安裝,注意做好交叉配合工作/r/n。/r/n電氣按照明、動/r/n力、弱電、/r/n根底接地/r/n防雷等分系統(tǒng)分班組施工;/r/n管道按給水系統(tǒng)、排水系統(tǒng)、雨水系統(tǒng)、消防/r/n水/r/n系統(tǒng)、/r/n消防/r/n噴淋系統(tǒng)、衛(wèi)生器具及空調(diào)水系統(tǒng)等分系統(tǒng)分班組施工/r/n;暖通工程按空調(diào)風管系統(tǒng)、通風系統(tǒng)、防排煙系統(tǒng)、空調(diào)水系統(tǒng)、冷凝水系統(tǒng)以及蒸汽和凝結(jié)水系統(tǒng)。/r/n3)/r/n隨著土建工程的進展,及人防工程的跟進,進駐現(xiàn)場的機電各專業(yè)安裝配合人員要同土建人員密切配合,并熟悉土建施工圖紙,排好與土建相協(xié)調(diào)的網(wǎng)絡(luò)進度方案、材料使用方案、勞動力作業(yè)方案等,做好各工藝管線、洞口預(yù)留、預(yù)埋工作。/r/n3.1、/r/n電氣工程/r/n〔/r/n含/r/n動力系統(tǒng)、照明系統(tǒng)、/r/n消防火災(zāi)報警、弱電、/r/n防雷接地系統(tǒng)〕/r/n前期/r/n主要是在/r/n人防與非人防區(qū)域/r/n結(jié)構(gòu)構(gòu)件梁、板和墻體中予埋管線/r/n及各類備用套管/r/n、防爆密閉接線盒的制作安裝/r/n,/r/n包括照明管及避雷接地線焊接與連接,控制好相關(guān)位置、標高和尺寸;設(shè)備安裝主要是固定設(shè)備的預(yù)留或預(yù)埋件等工作/r/n。/r/n預(yù)埋工作的準確與優(yōu)勢,將關(guān)系的到后序安裝工作的順利與好壞,因此要認真加以對待,同時預(yù)埋時不得發(fā)生對結(jié)構(gòu)性能產(chǎn)生破壞和削弱的現(xiàn)象。/r/n3.2、/r/n給排水管道工程/r/n〔含/r/n給水、排水系統(tǒng)、/r/n雨水系統(tǒng)、消防水、/r/n消防/r/n噴淋/r/n系統(tǒng)、太陽能熱水管道系統(tǒng)、衛(wèi)生器具/r/n〕/r/n前期/r/n主要是在人防與非人防區(qū)域結(jié)構(gòu)構(gòu)件梁、板和墻體中予埋給水/r/n、供回水/r/n套管、排水管道/r/n、/r/n水泵房各類套管,包括地下室衛(wèi)生間管道/r/n、各類進出戶剛性、柔性防水套管的預(yù)埋工作/r/n、固定設(shè)備的預(yù)留或預(yù)埋件等工作及后期的管道、設(shè)備安裝,需要嚴格/r/n控制好相關(guān)點位置、標高和尺寸/r/n。/r/n3.3、/r/n暖通工程/r/n〔含/r/n空調(diào)風管系統(tǒng)、通風系統(tǒng)、防排煙系統(tǒng)、空調(diào)水系統(tǒng)、/r/n自控系統(tǒng)、/r/n冷凝水系統(tǒng)以及蒸汽和凝結(jié)水系統(tǒng)/r/n〕/r/n。/r/n冷凍系統(tǒng)均采用高效冷水機組配冷卻塔、空調(diào)水系統(tǒng)采用二管制閉式循環(huán)系統(tǒng)。/r/n前期/r/n主要是在人防與非人防區(qū)域結(jié)構(gòu)構(gòu)件梁、板和墻體中予埋通風測壓、壓差等各類套管/r/n及固定設(shè)備的預(yù)留或預(yù)埋件等工作/r/n及后期的通風風管,空調(diào)風管的/r/n制作/r/n安裝,需要嚴格/r/n控制好相關(guān)點位置、標高和尺寸;/r/n通風大件套管預(yù)埋時不得發(fā)生對結(jié)構(gòu)性能產(chǎn)生破壞和削弱的現(xiàn)象。/r/n4/r/n〕/r/n、人防本卷須知/r/n4.1、人防水系統(tǒng):簡洗間、擴散室、防毒通道、密閉通道、濾毒室、人防通風井等處洗消予埋的防爆地漏及排水管〔通到染毒水池〕干廁等房間予埋普通地漏及排水管通過普通污水集水井,以上在底板施工中必須埋好。/r/n4.2、人防風系統(tǒng):戰(zhàn)時進、排風口處墻上的風管穿墻孔洞、穿墻短管、閥門、活門必須預(yù)留/r/n4.3、人防電系統(tǒng):穿過防護密閉墻的管線平時必須埋好./r/n〈四〉施工階段劃分/r/n/r/n/r/n本工程安裝工程共分五個階段施工,即施工準備階段、配合預(yù)留預(yù)埋階段、穿插安裝階段、安裝階段和調(diào)試檢測交工驗收階段。/r/n1、施工準備階段〔土方挖完前〕:該階段工作主要包括:施工組織設(shè)計、質(zhì)量保證方案、施工技術(shù)交底、平安技術(shù)交底的編制;圖紙會審和設(shè)計交底;熟悉圖紙,落實圖紙疑難問題;編制施工圖預(yù)算、施工預(yù)算和材料設(shè)備進場方案;編制工具采購方案和施工人員進場方案,編制標準圖集、標準規(guī)程、工藝標準方案和計量器具方案等。/r/n2、配合預(yù)留預(yù)埋階段〔土建主體工程〕:該階段工作必須將各專業(yè)圖紙進行內(nèi)部交叉會審,并進行施工交底,使各預(yù)埋班組彼此相互了解各專業(yè)范圍和專業(yè)的技術(shù)質(zhì)量要求,有無相互影響的情況。及時給建設(shè)單位和設(shè)計部門提出并得到解決。/r/n預(yù)留預(yù)埋工作必須按照技術(shù)施工員的作業(yè)指導(dǎo)書要求施工,預(yù)埋時跟班作業(yè),保證預(yù)留預(yù)埋到位,并注意保護好預(yù)埋的成品。預(yù)埋工作完成后在隱蔽前,所有預(yù)埋都必須對坐標、標高、規(guī)格、數(shù)量進行復(fù)核,做到數(shù)量、位置準確,防止二次打鑿。配合預(yù)留預(yù)埋階段設(shè)管道和電氣兩個預(yù)留預(yù)埋組,嚴格按圖紙、會審紀要要求預(yù)留管洞,預(yù)埋套管和管線,并畫好位置草圖。模盒固定牢靠,管口封堵,澆砼時派專人值班,以免預(yù)留預(yù)埋件移位、喪失或損壞,拆模后及時清理預(yù)留孔洞。預(yù)埋班組同時又是安裝班組,誰預(yù)埋誰施工,減少交接的麻煩。維持工作的連續(xù)性,責任清楚。/r/n3、穿插安裝階段〔主體三層完后〕:根據(jù)土建施工的進度情況,主體上到/r/n一/r/n層時就開始地下室局部的安裝,主要進行開關(guān)箱、盒就位,電氣管內(nèi)穿線,給排水立管安裝等工作,安裝高度根據(jù)/r/n藍圖說明及/r/n土建所確定的室內(nèi)標高線進行。通風組在地下室和加工棚進/r/n行通風管道管件的預(yù)制。/r/n穿插安裝階段設(shè)兩個管/r/n道工作業(yè)組,兩個電氣/r/n工作業(yè)組和一個通風加工組,管工、電工各一個組仍然負責預(yù)留預(yù)埋,另一個組從地下室開始向上層逐層穿插安裝。/r/n4、安裝階段〔主體封頂后〕:安裝全面鋪開,電氣線路,開關(guān)箱、盒全部安裝完畢,給排水全部到位,各用水點用堵頭封閉,在安裝末期開始設(shè)備的安裝,包括泵、報警閥、配電柜、冷卻塔等。管道、電氣、暖通三個專業(yè)五個班組同時進行大規(guī)模安裝,注意做好交叉配合工作,暖通工程〔含空調(diào)風管系統(tǒng)、通風系統(tǒng)、防排煙系統(tǒng)、空調(diào)水系統(tǒng)、冷凝水系統(tǒng)以及蒸汽和凝結(jié)水系統(tǒng)〕;管道/r/n〔/r/n給水系統(tǒng)、排水系統(tǒng)、/r/n太陽能熱水、/r/n雨水系統(tǒng)、消防系統(tǒng)、噴淋系統(tǒng)、衛(wèi)生器具/r/n〕/r/n分系統(tǒng)分班組施工,電氣/r/n〔/r/n照明、動力、/r/n消防報警/r/n、/r/n根底接地/r/n防雷/r/n〕/r/n分系統(tǒng)分班組施工。/r/n5、調(diào)試檢測交工階段〔安裝就位后〕:本工程需調(diào)試的有水泵變頻設(shè)備、自動噴淋報警閥、消防報警、通風系統(tǒng)、柴油發(fā)電機組等,各單項調(diào)試合格后進行消防聯(lián)動試車。本階段人員陸續(xù)退場,將各專業(yè)操作人員合并成一個班組,對本階段所有分項安裝內(nèi)容進行檢測、調(diào)試,并做好記錄,以備竣工驗收,同時做好成品保護工作。/r/n第四章主要分部、分項施工方/r/n案/r/n一/r/n、電氣局部/r/n〔一〕/r/n動力局部/r/n1、施工順序/r/n為保證工期,我們對本工程電氣施工工序、施工條件作了仔細的分析,制訂了嚴謹?shù)氖┕こ绦?,以保證過程產(chǎn)品的質(zhì)量與工期目標的要求。/r/n開工準備、持證上崗/r/n配合土建預(yù)埋線管/r/n土建提供安裝條件/r/n開工準備、持證上崗/r/n配合土建預(yù)埋線管/r/n土建提供安裝條件/r/n單回路調(diào)試單機運行/r/n電氣裝置檢查、接線/r/n電氣裝置設(shè)備安裝/r/n電纜槽、橋架安裝/r/n檢查、驗收/r/n橋架支、吊托架安裝/r/n接地端子安裝/r/n等電位聯(lián)接、接地/r/n防雷引下線/r/n防雷接地根底板安裝/r/n聯(lián)合調(diào)試全系統(tǒng)運行/r/n二次裝修電氣安裝/r/n系統(tǒng)調(diào)試、系統(tǒng)運行/r/n照明系統(tǒng)試亮/r/n照明系統(tǒng)測試/r/n照明電器安裝/r/n電纜、電線敷設(shè)/r/n接地測試/r/n等/r/n/r/n電/r/n/r/n位/r/n/r/n測/r/n/r/n試/r/n交工驗收、竣工報告/r/nⅢ/r/n、各工序主要施工方案及技術(shù)措施/r/n1./r/n結(jié)構(gòu)預(yù)埋階段/r/n1./r/n1/r/n/r/n.1/r/n針對本工程的特點在配合階段以下管線必須在結(jié)構(gòu)時期配合到主體結(jié)構(gòu)中。采用套管連接時套管的長度不應(yīng)小于管外徑的/r/n2.2/r/n倍,管口應(yīng)對準在套管的/r/n/r/n中心并焊接嚴密,可以不做跨接地線。/r/nDN70/r/n以上的線管明配時因機具的原因可以使/r/n/r/n用套管連接,/r/nDN20/r/n以下鍍鋅管暗配時宜絲扣連接,也可以套管連接。線管敷設(shè)采用套絲連接時,鍍鋅鋼管用專用接線卡作接地線,接地卡之間的/r/n/r/n接地線應(yīng)同管內(nèi)所穿的導(dǎo)本線的地線相同規(guī)格。/r/n1./r/n1/r/n/r/n.2所有穿越地下室圍護結(jié)構(gòu),防護密閉墻和密閉隔墻的電氣管線或預(yù)留的備用穿管應(yīng)分別作好防護密閉或密閉處理,管材采用熱鍍鋅鋼管,〔厚度不小于2.5mm〕具體做法詳見國家有關(guān)標準圖。每個防護密閉門和密閉門靠側(cè)邊梁底0.2米處應(yīng)預(yù)留SC100穿墻管6根作為戰(zhàn)時三防信號線穿越防護區(qū)時專用。8.7、應(yīng)急照明支路應(yīng)穿鋼管暗敷在樓板或墻內(nèi),由頂板接線盒至吊頂燈具一段明敷線路穿鋼質(zhì)波紋管或普利卡管并在管外壁做防火處理。人員主要出入口的第一道防護門外側(cè)應(yīng)設(shè)置呼喚門鈴按鈕,門鈴設(shè)于防護區(qū)內(nèi),門鈴按鈕須滿足抗爆要求,平時施工時注意在各人員出入口和連通口的防護密閉門門框墻、密閉門框墻上方預(yù)埋穿線管。應(yīng)急照明支路應(yīng)穿鋼管暗敷在樓板或墻內(nèi),由頂板接線盒至吊頂燈具一段明敷線路穿鋼質(zhì)波紋管或普利卡管并在管外壁做防火處理。/r/n1./r/n2/r/n為保證電氣工程的施工質(zhì)量,本工程頂板配合時采用了高腳八角接線盒,這樣解決了頂板鋼筋大而普通接線合厚度小,接線盒無法粘在模板上的施工難題。/r/n1.3/r/n公共照明及插座局部的鋼管必須在結(jié)構(gòu)配合中一次預(yù)埋,其它如辦公室的/r/n/r/n照明/r/n(/r/n只要有吊頂處的辦公室、接待室等/r/n)/r/n均可在粗裝修階段進行。/r/n1./r/n4/r/n/r/n所有穿外墻的管線一定要焊止水片,并做到外低里高。/r/n2/r/n、/r/n鍍鋅鋼管/r/n明敷設(shè)/r/n所有明配并與消防系統(tǒng)有關(guān)的管線均應(yīng)涮防火漆。/r/n①/r/n施工流程/r/n施工準備/r/n→/r/n測位彈線/r/n→/r/n線管預(yù)制、煨彎/r/n→/r/n線管、線盒連接、固定/r/n→/r/n接地線跨接/r/n→/r/n接地電阻測試。/r/n②/r/n施工方法/r/n本項工序施工前土建樓面、墻體抹灰工作應(yīng)已經(jīng)結(jié)束;/r/n依現(xiàn)場情況確定線管走向〔為使配管整齊美觀,管路沿梁、樓板底、柱水平或垂直敷設(shè)〕,并用粉線彈出線管位置;/r/n依據(jù)所量尺寸用鋼鋸切斷或煨彎電線管,切斷口平整、光滑無毛刺,彎曲處無折扁、凹陷及裂縫,彎曲半徑大于管外徑的/r/n6/r/n倍;/r/n鍍鋅/r/n鋼管/r/n應(yīng)采用螺紋連接,其螺紋長度不小于管接頭長度的一半,螺紋外表光滑;/r/n線管敷設(shè)時排列整齊,其允許誤差為:每/r/n2m/r/n不大于/r/n3mm/r/n,全長不應(yīng)超過管內(nèi)徑的/r/n1/2/r/n;/r/n線管固定點間距均勻,因為管子沿墻壁、柱子和梁敷設(shè),所以可直接用離墻碼固定,離墻碼與終端、轉(zhuǎn)彎中點、電器或接線盒邊緣的距離為/r/n150/r/n~/r/n500mm/r/n,中間的離墻碼最大距離符合下表規(guī)定:/r/n敷設(shè)方式/r/n管線名稱/r/n線管直徑〔mm〕/r/n沿墻敷設(shè),吊架、支架敷設(shè)/r/n15~20/r/n25~30/r/n40~50/r/n最大允許距離〔m〕/r/n薄壁鋼管/r/n1.0/r/n1.5/r/n2.0/r/n管子在梁下敷設(shè)時梁下一定要有接線盒,且兩側(cè)均要固定好。吊頂內(nèi)配管按明配管標要求進行,該有支架的地方一定要有,該有接線盒的地方一定要加,且不能有落下的現(xiàn)象。支架固定要牢固。/r/n所有明配管的走向如果一致/r/n,/r/n決不可出現(xiàn)標配管走向不同的現(xiàn)/r/n/r/n象。在施工時要畫出詳細的施工吊頂施工圖,按此圖施工。/r/n根據(jù)設(shè)計圖要求,確定盒、箱實際的軸線位置,以土建彈出的軸線與水平線/r/n/r/n為基準,掛線找平,線墜找正,標出盒、箱實際的軸線位置,實際的尺寸位置,要了/r/n/r/n解各室〔廳〕地面構(gòu)造,留出余量,使盒、箱的外蓋、底邊和最終地面距離符合標準/r/n/r/n要求。/r/n當線管貼墻敷設(shè)入開關(guān)、插座等接線盒孔內(nèi)時,要適當將管子煨成雙彎〔鴨脖彎〕,如以下列圖示,不能使管子斜穿到線盒內(nèi),同時要使管子平整地緊貼在建筑物上,在距離接線盒/r/n30mm/r/n處加離墻碼固定,在有彎頭的地方,彎頭兩邊也應(yīng)加離墻碼固定。/r/n線管與線管,線管與線盒/r/n//r/n電箱間的所有接口處均要用專用接地線夾跨接,/r/n跨接銅線截面不應(yīng)小于/r/n4/r/nmm/r/n2/r/n;/r/n強電接線盒與弱電接線盒的平安距離不小于20cm. /r/n用接地電阻測試儀測試整個管路的接地情況。/r/n2、/r/n防火金屬/r/n線槽安裝方法/r/n①/r/n施工流程/r/n施工準備/r/n→/r/n彈線定位/r/n→/r/n支架、吊架安裝/r/n→/r/n線槽安裝/r/n→/r/n線槽接地/r/n→/r/n接地電阻測試。/r/n②/r/n施工方法/r/n本項工序施工前土建樓面、墻體抹灰工作應(yīng)已經(jīng)結(jié)束。/r/n施工前應(yīng)熟悉圖紙,熟悉現(xiàn)場環(huán)境,注意與管道、通風專業(yè)協(xié)調(diào)好/r/n標高/r/n,并依據(jù)現(xiàn)場環(huán)境確定線槽走向、支架或吊架的規(guī)格;/r/n支架安裝前彈水平線,安裝時彈豎直線,安裝后的支架/r/n//r/n吊架橫平豎直;/r/n支架/r/n//r/n吊架安裝牢固、豎直,間隔均勻,每隔/r/n1.5/r/nm/r/n安裝一個支架,并在線槽的首末端、分支及拐彎處增設(shè)/r/n防晃/r/n線槽切斷口整齊、光滑,連結(jié)緊密、牢固,出線口位置正確,末端作封口處理;/r/n線槽與配電箱/r/n//r/n配電柜連接時,進線口和出線口處采用抱腳連接,并用螺栓緊固;/r/n線槽進行交叉、轉(zhuǎn)彎、丁字連接時,采用二通、三通、四通等進行變通連接,如不用配件作變通連接,那么線槽轉(zhuǎn)彎處制成/r/n45/r/n度角過度;/r/n當線槽與風管、水管位置相交叉時,線槽應(yīng)敷設(shè)在它們的上方,同時注意防止通過噴淋頭上方;/r/n當電線槽與管道平行敷設(shè)時,假設(shè)位置允許時,兩者間距保持在/r/n30/r/ncm/r/n當建筑物外表有坡度時,線槽隨其相應(yīng)變化坡度;/r/n線槽蓋板要齊全,平直、連接緊密、固定牢固;/r/n線槽安裝完畢后橫平豎直,垂直誤差不大于/r/n5/r/nmm/r/n,全長水平誤差不大于/r/n20/r/n電纜井內(nèi)線槽安裝:/r/n施工前管井內(nèi)的雜物應(yīng)清理干凈;/r/n支架安裝先吊線再安裝,安裝后的支架橫平豎直;/r/n支架固定時要除去墻面批蕩層,膨脹螺栓采用/r/n10/r/n×/r/n50mm/r/n,每/r/n1.5m/r/n一個支架,且在線槽〔橋架〕轉(zhuǎn)彎處應(yīng)增設(shè)固定點/r/n〔防晃支架〕/r/n,支架固定牢固、平整,間隔均勻;/r/n橋架〔線槽〕安裝與供電局施工隊協(xié)調(diào)好,安裝順序擬為:支架安裝/r/n→/r/n橋架就位/r/n→/r/n電表箱/r/n/配電箱/r/n支架安裝/r/n→/r/n橋架固定。原因是假設(shè)橋架固定后電表箱支架無法固定,而假設(shè)/r/n電表箱/配電箱/r/n支架固定后,橋架無法就位;/r/n線槽〔橋架〕接口應(yīng)平直、嚴密,出線口應(yīng)位置正確、光滑,末端封口,槽蓋齊全、平整無翹角;/r/n線槽/r/n//r/n橋架與水平段線槽/r/n//r/n橋架連接時采用凸型或凹型二通進行變通連接;/r/n線槽〔橋架〕安裝完畢后橫平豎直,水平誤差不能大于/r/n5/r/nmm/r/n,全長垂直誤差不能大于/r/n20/r/n強電井內(nèi)橋架〔/r/n室內(nèi)/r/n線槽〕分布方案如以下列圖:/r/n3、電纜敷設(shè)及終端頭制安方案/r/n①/r/n施工流程/r/n②/r/n施工準備/r/na、材料、機具準備/r/nb、施工人員準備:/r/n③/r/n電纜敷設(shè)施工方法/r/na、施工前:/r/n線槽、配電箱〔柜〕應(yīng)安裝完畢;/r/n熟悉所敷電纜的規(guī)格、長度、敷設(shè)路徑及部位/r/n〔注意預(yù)分支電纜/r/n的方案/r/n〕/r/n,/r/n在橋架上多根電纜敷設(shè)時,應(yīng)根據(jù)現(xiàn)場實際情況,事先將電纜的排列用表或圖的方式畫出來,并計算出電纜長度,以防電纜的交叉和混亂。/r/n做好準備工作,如通道清理、電纜盤編號、路徑標注、長度測量、電纜架及倒鏈就位等;/r/n對所敷設(shè)的電纜進行絕緣測試,絕緣電阻值需大于/r/n10/r/n兆歐。/r/nb、施工中:/r/n嚴格按照設(shè)計圖紙及電纜敷設(shè)順序進行敷設(shè)。電纜放線架放置穩(wěn)妥,鋼軸的強度和長度與電纜盤重量和寬度相批配。/r/n電纜中間嚴禁有接頭,電纜終端頭預(yù)留長度適當,按配電箱〔柜〕的〔長+寬〕預(yù)留。/r/n電纜敷設(shè)時彎曲半徑/r/nR/r/n≥/r/n15D/r/n〔/r/nD/r/n為電纜外徑〕。電纜敷設(shè)時排列整齊,盡量防止交叉,固定牢固,并在終端裝設(shè)標志牌。線槽內(nèi)的電纜總截面積不大于線槽截面積的/r/n75%/r/n。/r/n電纜敷設(shè)后應(yīng)用電纜扎帶加以固定,扎帶頭過長的要剪去;并作好電纜敷設(shè)記錄及電纜絕緣測試記錄,電纜頭應(yīng)包扎并保護好。/r/n普通照明與應(yīng)急照明不同性質(zhì)電源敷設(shè)在同/r/n一橋架內(nèi)必須使用金屬隔離板/r/nc、施工后:/r/n用電纜扎帶綁扎固定,垂直敷設(shè)的電纜在橋架上每隔/r/n2/r/nm/r/n在電纜頭的兩端掛標志牌,標志牌上注明電纜編號、型號、規(guī)格及迄止點位置。/r/n再次對電纜進行絕緣搖測,并比較兩者間的阻值大小。/r/n作好電纜敷設(shè)記錄及電纜絕緣測試記錄。/r/n電纜終端頭作包扎處理。/r/nd、施工中的平安本卷須知:/r/n施工中必須注意平安,聽從指揮。/r/n平安帽及防護手套要佩戴好。/r/n電纜放線架放置要穩(wěn)妥,電纜頭鋼絲網(wǎng)套綁扎要牢固,電纜與鋼絲網(wǎng)套間要裝設(shè)防捻裝置。平行敷設(shè)時,木梯必須用加固型,并放置穩(wěn)固,嚴禁用鐵梯及缺檔的梯子。發(fā)現(xiàn)問題應(yīng)及時報告。/r/n④/r/n豎井內(nèi)的電纜采用機械化敷設(shè)方法:電纜放線架置于首層電纜附近,在天面頂層設(shè)置一臺/r/n2T/r/n的卷揚機,電纜井內(nèi)設(shè)置一滑輪組,以調(diào)整拉力方向,定滑輪由電梯機房內(nèi)的預(yù)埋件加以固定;電纜頭用鋼絲網(wǎng)套套住,中間加防捻器以防電纜頭脫落,另一端用/r/nφ/r/n15/r/n鋼絲繩牽引,鋼絲繩在運行時不應(yīng)受損傷。/r/n機械化敷設(shè)電纜人員配置:/r/n樓層/r/n人數(shù)/r/n職能/r/n備注/r/n首層/r/n4人/r/n操縱電纜盤及監(jiān)護電纜運行/r/n配置對講機1臺/r/n3人/r/n監(jiān)護電纜頭運行/r/n配置對講機1臺/r/n每5層/r/n1人/r/n迅速綁扎電纜/r/n天面/r/n4人/r/n操縱卷揚機及監(jiān)護鋼繩運行/r/n配置對講機1臺/r/n1人/r/n總指揮/r/n本卷須知:/r/n在所有轉(zhuǎn)彎處要設(shè)置滑輪。/r/n卷揚機運行速度不能超過/r/n15m/r/n/min/r/n,并且勻速運行。/r/n卷揚機、鋼絲繩、鋼絲網(wǎng)套、滑輪等的規(guī)格要與所敷設(shè)電纜相匹配,并經(jīng)過嚴密計算。/r/n鋼絲網(wǎng)套綁扎要牢固,且要裝防捻器。/r/n要安排專人監(jiān)護電纜頭運行情況,電纜頭運行時不能受到阻礙。/r/n嚴禁高空墜物,嚴禁非作業(yè)人員靠近電纜井。/r/n4、配電箱、配電柜安裝及二次回路接線方法/r/n①/r/n施工流程/r/n設(shè)備開箱檢查/r/n→/r/n支架底座制安/r/n→/r/n設(shè)備運輸/r/n→/r/n盤、柜安裝/r/n→/r/n二次回路接線/r/n→/r/n試驗調(diào)整/r/n→/r/n送電運行。/r/n②/r/n施工方法/r/n盤、柜的金屬框架整潔無變形,根底型鋼接地可靠,油漆完整均勻;/r/n盤柜上面不能用氣、電焊開孔,不能與底座型鋼焊死;/r/n抽屜式或手推式配電柜抽屜推拉靈活輕便,無卡阻碰撞現(xiàn)象,觸頭中心線一致,且接觸緊密,機械連鎖或電氣連鎖動作正確可靠,接地觸頭接地良好;/r/n根底型鋼及盤柜安裝允許偏差如下表:/r/n根底型鋼允許偏差〔mm〕/r/n盤柜安裝允許偏差〔mm〕/r/n頂部平直度/r/n側(cè)面平直度/r/n每米垂直度/r/n盤頂平直度/r/n盤面平直度/r/n盤間接縫/r/n每米/r/n全長/r/n每米/r/n全長/r/n相鄰兩盤/r/n成排/r/n相鄰兩盤/r/n成排/r/n1/r/n5/r/n1/r/n5/r/n1./r/n5/r/n2/r/n5/r/n1/r/n5/r/n2/r/n盤柜內(nèi)的電器設(shè)備型號、規(guī)格符合設(shè)計要求,附件齊全,排列整齊,固定可靠,電氣接觸良好,信號裝置回路顯示正確、工作可靠;/r/n盤柜內(nèi)二次接線正確,連接牢固可靠,走向合理,配線整齊美觀,導(dǎo)線絕緣良好,盤柜內(nèi)無接頭,回路編號正確清楚;/r/n柜內(nèi)母線色標均勻完整,接地〔零〕截面選用正確,需防腐的局部涂漆均勻無遺漏。/r/n③/r/n動力系統(tǒng)調(diào)試方案/r/na、施工范圍:暫定變壓器后所有線路及發(fā)動機配電系統(tǒng)。/r/nb、施工準備:特殊機具、器具準備/r/n序號/r/n名稱/r/n單位/r/n數(shù)量/r/n1/r/n對講機/r/n個/r/n6/r/n2/r/nCO2/r/n滅火器/r/n瓶/r/n2/r/n3/r/n絕緣膠鞋/r/n對/r/n4/r/n4/r/n絕緣手套/r/n對/r/n4/r/n5/r/n板手/r/n把/r/n4/r/n6/r/n膠鉗/r/n把/r/n4/r/n7/r/n螺絲批/r/n支/r/n假設(shè)干/r/n8/r/n手電筒/r/n只/r/n6/r/n9/r/n電流鉗表/r/n只/r/n2/r/n10/r/n數(shù)字萬用表/r/n只/r/n4/r/n11/r/n絕緣電阻測試儀表/r/n只/r/n2/r/n12/r/n警示牌/r/n塊/r/n6/r/n13/r/n試驗電筆/r/n只/r/n2/r/nc、技術(shù)準備:/r/n圖紙準備:高、低壓配電系統(tǒng)圖,照明、動力系統(tǒng)圖,配電箱/r/n//r/n配電柜一、二次接線圖等。/r/n對照圖紙,核對各回路的走向/r/n//r/n路徑。/r/n動力系統(tǒng)調(diào)試記錄表:/r/n序號/r/n圖號/r/n回路編號/r/n絕緣情況/r/n通電情況/r/n問題原因/r/n備注/r/nd、人員準備:調(diào)試前要組織調(diào)試小組,明確指揮者、操作者以及監(jiān)護人。/r/ne、調(diào)試步驟:/r/na〕送電前確認:/r/n末端回路已用臨時電源試驗,末端回路〔支路〕無問題。/r/n配電箱安裝及接線經(jīng)檢查已符合要求,且箱內(nèi)經(jīng)過清掃。/r/n供電局已送電至低壓柜的一次側(cè)。/r/nb〕通電時:/r/n對所要通電的回路用絕緣電阻測試儀測試其絕緣電阻,確認該回路相間、相零、相地間的絕緣電阻值符合要求。/r/n把所要通電回路上配電箱/r/n//r/n配電柜內(nèi)的主開關(guān)/r/n//r/n刀閘打下,確認本回路上所有負荷已經(jīng)切除。/r/n用萬用表檢測低壓柜一次側(cè)電壓,確認該電源電壓正常。/r/n試驗人員戴上絕緣手套,穿上絕緣膠鞋,迅速合閘。/r/n在回路的另一側(cè)用萬用表檢查電源是否正常,相序是否正確。/r/n把該回路上主開關(guān)合上,帶上負荷檢查。/r/n重復(fù)上述步驟對其他回路送電。/r/n記錄調(diào)試結(jié)果。/r/nc〕本卷須知:/r/n調(diào)試時要與供電局取得聯(lián)系,并明確各自的職責。/r/n勞動保護用品要備齊,并且操作者旁邊要有監(jiān)護人。/r/n當某一回路發(fā)生問題時,必須查明原因,并維修好后,方能再送電。/r/ne〕送電不出的原因分析:/r/n線路問題:可用絕緣電阻測試儀表進行檢測,當回路絕緣電阻值小于/r/n0.5M/r/nΩ/r/n時,說明回路有問題,可采用分段檢測,各個擊破的方法進行檢查;/r/n接線問題:當線路絕緣電阻值正常的情況下,檢查配電箱內(nèi)導(dǎo)線是否掉錯;/r/n回路漏電斷路器的問題:當接線正確,并且回路絕緣電阻值正常的情況下,檢查是否漏電開關(guān)有質(zhì)量問題,可換一新的相同規(guī)格的漏電斷路器試驗;/r/n用電設(shè)備的問題:當回路不帶負荷時可送電,而回路帶負荷時不能送電,并且回路漏電斷路器容量滿足負荷要求時,檢查用電設(shè)備本身線路是否有問題。/r/n〔二〕/r/n電氣照明局部/r/n1、施工流程/r/n①/r/n照明管線暗裝/r/n跑坑/r/n→/r/n敷管/r/n→/r/n穿線/r/n→/r/n對線、接線/r/n→/r/n燈具、開關(guān)、插座安裝/r/n→/r/n調(diào)試。/r/n②/r/n照明管線明裝/r/n線槽敷設(shè)/r/n→/r/n配線/r/n→/r/n對線、接線/r/n→/r/n燈具、開關(guān)、插座安裝/r/n→/r/n調(diào)試。/r/n2、安裝前應(yīng)已經(jīng)編制有針對性的、詳細的施工方案,該方案需經(jīng)審批通過。/r/n3/r/n、施工前需進行詳細的圖紙會審工作,/r/n應(yīng)了解以下幾點:/r/n①/r/n進戶線的位置及總配電箱、分配電箱的位置,明確配電箱是明裝還是暗裝。/r/n②/r/n進戶線、干線、支線的走向,導(dǎo)線根數(shù),以及支線回路的劃分。/r/n導(dǎo)線的敷設(shè)部位、敷設(shè)方式、導(dǎo)線穿管敷設(shè)時所用的管材、管徑。為說明完整及圖面整潔,常是用平面圖和系統(tǒng)圖互相補充。由于支線數(shù)目較多,又常采用統(tǒng)一的導(dǎo)線敷設(shè)方法,所以一般圖上不標注,而在施工說明中去找。/r/n4、燈具、燈具開關(guān)、插座、排氣扇的安裝容量、安裝方式及懸掛高度。/r/n5、配電箱中的控制、保護設(shè)備及計量儀表:在平面圖上只能表示出配電箱的安裝方式〔明裝還是暗裝〕,但是在配電箱內(nèi)有哪些控制、保護設(shè)備及儀表都表示不出來,這些只有在系統(tǒng)圖中才能看到。/r/n6、接線盒〔箱〕的安裝應(yīng)平整牢固,與鋼管連接緊密,鋼管進入燈頭盒,開關(guān)盒〔箱〕時,明配管應(yīng)用鎖緊迫母固定,露出絲扣為2~4扣。暗配管可用焊接固定,管口露出盒〔箱〕應(yīng)小于/r/n5mm/r/n。/r/n7、因設(shè)計修改,暗敷管需延伸至某用電點時,須用電線管連接,不能使用金屬軟管。/r/n8、明配管連接局部用/r/n6/r/n銅電線接跨接,管子預(yù)穿鐵絲,管口裝上塑料護套,然后堵上木枳。/r/n9、電線管穿線后嚴禁在管線上施焊及作電焊接地通路,防止損壞導(dǎo)線絕緣層,造成線路短路。/r/n鍍鋅鋼管嚴禁焊接/r/n。/r/n10、鋼管穿線每一回路導(dǎo)線之間和對地的絕緣電阻阻值不得小于/r/n1M/r/n/r/n。/r/n11、穿線時應(yīng)按標準分色編碼。這項工作十分重要,必須從編制材料方案就開始抓起,領(lǐng)料、穿線、接線時應(yīng)重復(fù)核對。/r/n12、燈具、器具安裝/r/n①/r/n燈具、開關(guān)、插座的安裝應(yīng)平整、牢固,清潔整齊,高度一致,位置正確、開關(guān)應(yīng)切斷相線。暗開關(guān)和暗插座安裝的垂直度及相鄰上下差應(yīng)符合要求〔按標高尺寸在走廊始終端粒粉線,另統(tǒng)一門框邊至線盒的距離,可在/r/n15/r/n~/r/n20cm/r/n范圍選定〕。/r/n②/r/n所有金屬吸頂架盒、燈具均應(yīng)采用保安接零,保安接零與接地裝置共用,接地電阻不大于/r/n1Ω/r/n。/r/n③/r/n插座地線要可靠,相線零線、地線安裝應(yīng)符合標準要求。/r/n④/r/n燈具安裝應(yīng)配合裝修,筒燈金屬外殼可靠接地,不得在天花內(nèi)裸露電線,嚴禁裸露駁接線口。燈具線路假設(shè)在天花內(nèi)有駁口時應(yīng)設(shè)接線盒。/r/n三、調(diào)試驗收/r/n1、試火/r/n①/r/n按圖線編號穿線時各回路應(yīng)套上端子標識清楚,試火時應(yīng)每回路逐一通電。/r/n②/r/n試火前每一回路用搖表搖測絕緣作好記錄。/r/n③/r/n試火時發(fā)現(xiàn)漏電保護開頭動作,應(yīng)查明原因后,試火方可繼續(xù)進行。/r/n④/r/n試火時應(yīng)每一燈具插座進行,不得抽試。/r/n2、調(diào)試/r/n①/r/n絕緣電阻測試。在各回路送電之前進行一次絕緣電阻測試工作,確認各回路絕緣電阻達至標準要求。/r/n②/r/n分支回路送電時每次送電只能送一個回路,不能各回路同時送電。在送電前,所有的開關(guān)都不能翻開。送電后,再逐個開關(guān)翻開觀察燈具是否正常工作。檢查完該開關(guān)控制的燈具后即關(guān)上開關(guān),再翻開下一個開關(guān)逐個進行檢查。/r/n〔三〕/r/n消防報警/r/n、背景音樂及緊急播送系統(tǒng)/r/n此工程/r/n分消防報警、背景音樂及緊急播送系統(tǒng)。/r/n按照藍圖做好管子的預(yù)埋,并清理疏通/r/n及/r/n后期的設(shè)備安裝/r/n一〕、/r/n消防報警/r/n系統(tǒng)說明:/r/n/r/n1./r/n本工程采用環(huán)形總線控制中心報警系統(tǒng),對全樓的火災(zāi)信號和消防設(shè)備進行監(jiān)視及控制?;馂?zāi)自動/r/n/r/n報/r/n/r/n警系統(tǒng)的每回路地址編碼總數(shù)不超過/r/n200/r/n點,并考慮留出/r/n15%~20%/r/n的余量。/r/n/r/n2./r/n在商業(yè)零售,樓梯間,走道,餐廳、車庫等場所設(shè)置感煙探測器;在鍋爐房、發(fā)電機房、廚房等設(shè)置溫感;中庭〔高大空間〕設(shè)置紅外對射探測器。/r/n/r/n3./r/n在本建筑的主要出入口、疏散樓梯口等場所設(shè)置手動報警按鈕及消防對講插口,從一個防火分區(qū)內(nèi)的任何位置到最鄰近的一個手動報警按鈕的距離不大于/r/n30/r/n米/r/n。手報底邊距地/r/n1.4m/r/n安裝。聲光警報裝/r/n/r/n置主要設(shè)置在疏散樓梯前室走道側(cè),安裝高度不低于/r/n2.2m/r/n。/r/n4./r/n在消火栓箱內(nèi)設(shè)置消火栓報警按鈕,有獨立地址碼,接線盒設(shè)在消火栓的開門側(cè)上部。/r/n5/r/n./r/n本工程消防控制中心設(shè)在首層,并設(shè)有直接通往室外的出口。消防控制中心的報警控制設(shè)備由火災(zāi)報警控制主機、聯(lián)動控制臺、顯示器、打印機、應(yīng)急播送設(shè)備、消防直通對講設(shè)備、電梯監(jiān)控盤和電源設(shè)備等組成。/r/n/r/n6/r/n./r/n消防控制中心可接收感煙、感溫等探測器的火災(zāi)報警信號及水流指示器、檢修閥、壓力/r/n/r/n報警閥、手動報警按鈕、消火栓按鈕的動作信號/r/n;/r/n還可接收排煙閥、加壓閥、/r/n280/r/n℃/r/n防火閥的動作信號。/r/n7/r/n./r/n消防控制中心可顯示消防水箱/r/n//r/n水池水位,顯示消防水泵的電源及運行狀況,并可聯(lián)動控制所有與消防有關(guān)的設(shè)備。在消控中心設(shè)備聲光報警器,一旦主機接收到消防報警信號,聲光報警器聯(lián)動鳴響。/r/n/r/n二/r/n〕、消防聯(lián)動控制/r/n功能描述/r/n:/r/n/r/n1./r/n火災(zāi)報警后,消防控制室根據(jù)火災(zāi)情況控制相關(guān)層的正壓送風閥及排煙閥、電動防火閥、并啟動相應(yīng)加壓送風機、排煙風機,排煙閥/r/n280/r/n℃/r/n熔斷關(guān)閉,閥、風機的動作信號要反響至消防控制中心。對消火栓泵、噴淋泵、加壓送風機、排煙風機,既可通過現(xiàn)場模塊進行自動控制也可在聯(lián)動控制臺上通過硬線手動控制,并接收其反響信號。/r/n2/r/n./r/n對消火栓系統(tǒng)的監(jiān)視與控制:/r/n/r/n1/r/n〕消火栓按鈕動作信號作為報警信號及啟動消火栓泵的聯(lián)動觸發(fā)信號,由消防聯(lián)動控制器聯(lián)動控制消/r/n/r/n火栓泵的啟停,并接收其反響信號。/r/n/r/n2/r/n〕消防控制中心可通過控制模塊編程,自動啟動消火栓泵,并接收其反響信號。/r/n/r/n3/r/n〕在消防控制中心聯(lián)動控制臺上,可通過硬線手動控制消火栓泵,并接收其反響信號。/r/n/r/n4/r/n〕消防控制中心能顯示消火栓泵電源狀況。/r/n/r/n5/r/n〕消防泵房可手動啟動消火栓泵。/r/n/r/n3/r/n./r/n對自動噴水系統(tǒng)的監(jiān)視和控制:/r/n/r/n1/r/n〕由濕式報警閥壓力開關(guān)動作信號作為觸發(fā)信號,直接控制啟動噴淋泵。水流指示器、信號閥、壓力開關(guān)、噴淋泵的啟停信號應(yīng)反響至消防聯(lián)動控制器。/r/n/r/n2/r/n〕消防控制中心可通過控制模塊編程,自動啟動噴淋泵,并接收其反響信號。/r/n/r/n3/r/n〕在消防控制中心聯(lián)動控制臺上,可通過硬線手動控制噴淋泵,并接收其反響信號。/r/n/r/n4/r/n〕消防控制中心能顯示噴淋泵電源狀況。/r/n/r/n5/r/n〕消防泵房可手動啟動消火栓泵。/r/n/r/n4./r/n對正壓送風系統(tǒng)的監(jiān)視和控制:/r/n由消防控制中心自動或手動控制正壓送風機的啟停,風機啟動時根據(jù)其功能位置連鎖開啟其相關(guān)的正壓送風閥或火災(zāi)層及鄰層的正壓送風口。/r/n/r/n/r/n5./r/n對排煙風機的監(jiān)視和控制:由同一防煙分區(qū)內(nèi)兩只獨立的火災(zāi)探測器的報警信號作為觸發(fā)信號,聯(lián)動開啟相應(yīng)區(qū)域的的排煙閥、排煙口及排煙窗,同時啟動相應(yīng)的排煙風機并停止空調(diào)系統(tǒng);當火災(zāi)溫度到達/r/n280/r/n℃/r/n時,/r/n排煙閥熔絲熔斷,排煙閥關(guān)閉。當排煙風機吸入口處的/r/n280/r/n℃/r/n6./r/n對排風兼排煙風機監(jiān)視和控制:/r/n/r/n正常情況下為通風換氣使用,火災(zāi)時那么作為排煙風機使用。正常時為就地手動控制及/r/nDDC/r/n控制,當火災(zāi)發(fā)生時由消防控制室控制,其控制方式與排煙風機相同。消防控制室具有控制優(yōu)先權(quán)。/r/n/r/n/r/n7./r/n對防火卷簾門的控制:/r/n/r/n1/r/n〕用于防火分隔的卷簾門為一步落下,在通道上的卷簾門分兩步落下。/r/n/r/n2/r/n〕一步落下卷簾門,由其所在防火分區(qū)內(nèi)任兩只獨立火災(zāi)探測器的報警信號作為觸發(fā)信號控制卷簾直接下降至樓板。疏散通道上的卷簾門由所在防火分區(qū)內(nèi)任兩只獨立感煙探測器的報警信號控制下降至/r/n1.8m/r/n處,任一只專門用于聯(lián)動防火卷簾的感溫探測器的報警信號聯(lián)動控制卷簾下降到底。在卷簾任一側(cè)距卷/r/n取/r/n簾縱深/r/n0.5~/r/n5m/r/n內(nèi)設(shè)置不少于/r/n2/r/n只專門聯(lián)動防火卷簾的感溫探/r/n/r/n測器。卷簾門關(guān)閉信號反響到消防控制中心。/r/n/r/n3/r/n〕卷簾門兩側(cè)設(shè)就地控制按鈕,底距地/r/n1.4m/r/n。/r/n/r/n4/r/n〕卷簾門下降時,在門兩側(cè)頂部有聲、光警報裝置。/r/n/r/n5/r/n〕每臺防火卷簾配置控制及信號模塊,可通過控制模塊在消防控制中心自動/r/n//r/n手動控制卷簾下降到底及通過信號模塊接收卷簾下降到底返回信號。/r/n/r/n8./r/n電梯控制:/r/n/r/n火災(zāi)發(fā)生時,根據(jù)火災(zāi)情況及場所,由消防控制室電梯控制盤發(fā)出指令。指揮電梯按消防程序運行:對全部或任意一臺電梯進行對講,說明改變運行程序的原因;除消防電梯保持運行外,其余電梯均要強制返回首層并將轎箱門翻開。電梯運行監(jiān)視控制盤與相應(yīng)的控制電纜由電梯廠商提供。/r/n/r/n9./r/n非消防電源控制:/r/n/r/n本工程局部低壓出線回路及所有各層插接箱內(nèi)設(shè)有分勵脫扣器,由消防控制中心在火災(zāi)確認后斷開相關(guān)電源。/r/n/r/n/r/n10、消防專用系統(tǒng):/r/n/r/n在消防控制室內(nèi)設(shè)置消防專用直通對講總機;除在手動報警按鈕上設(shè)置消防專用塞孔外,在消防水泵房、變配電室,發(fā)電機房,防排煙風機房,電梯機房,冷凍機房,警衛(wèi)值班室等場所還設(shè)有消防專用分機,分機底邊距地/r/n1.4m/r/n安裝;消防控制室設(shè)置直接報警的外線。/r/n/r/n/r/n11、供電電源:/r/n/r/n本工程火災(zāi)報警控制器采用專用回路供電,火災(zāi)自動報警系統(tǒng)的主電源采用消防電源,直流備用電源采用火災(zāi)報警控制器的專用蓄電池。火災(zāi)自動報警系統(tǒng)中的圖文工作站、消防通信設(shè)備等的電源,由消控室/r/nUPS/r/n裝置供電。/r/n12、系統(tǒng)設(shè)備及管線敷設(shè)的技術(shù)要求:/r/n/r/n1/r/n〕/r/n./r/n系統(tǒng)的成套設(shè)備,包括報警控制器、聯(lián)動控制臺、顯示器、打印機、消防專用總機、對講錄音及電源設(shè)備等均為成套供貨,并負責安裝、調(diào)試。/r/n/r/n2/r/n〕/r/n./r/n火災(zāi)自動報警線路及/r/n50V/r/n以下的供電線路、控制線路采用無鹵低煙阻燃耐火線纜。暗敷線管在樓板或墻內(nèi)的保護層厚度不應(yīng)小于/r/n30mm/r/n;明敷線管必須為熱鍍鋅鋼管,并應(yīng)采取涂防火涂料等防/r/n/r/n火/r/n/r/n保護措施;封閉式金屬線槽應(yīng)采/r/n涂防火涂料等防火保護措施。由頂板接線盒至消防設(shè)備一段線路/r/n/r/n穿金屬耐火〔阻燃〕波紋管。所有穿過建筑物伸縮縫、沉降縫、后澆帶的管線應(yīng)按國家、地方標準/r/n/r/n圖集中有關(guān)作法施工。管線敷設(shè)應(yīng)按施工標準要求及標準工料及工藝要求設(shè)置中間過線盒。/r/n/r/n3/r/n〕/r/n./r/n電纜橋架穿過防煙分區(qū)、防火分區(qū)、樓層時應(yīng)在安裝完畢后,用防火材料填充封堵。/r/n/r/n背景音樂及緊急播送系統(tǒng)/r/n一〕、系統(tǒng)說明:/r/n背景音響及緊急播送系統(tǒng)設(shè)備安裝在消防控制室內(nèi),設(shè)備包含CD、MP3播放器、FM接受裝置、網(wǎng)絡(luò)控制器、功率放大器、呼叫站、分區(qū)及音量控制器,遠程呼叫站等。/r/n商業(yè)大堂、公共衛(wèi)生間、公共走道、客用電梯廳等區(qū)域播放背景音樂;物業(yè)辦公室,消防通道、設(shè)備機房、商業(yè)租戶、后勤、地下停車場的區(qū)域播放緊急播送。/r/n背景音樂及緊急播送系統(tǒng)合用,控制主機要求與火災(zāi)自動報警系統(tǒng)聯(lián)動。在緊急情況下由/r/n火災(zāi)報警主機發(fā)出信號強切播放緊急信息,平時播放背景音樂。/r/n系統(tǒng)主機具有自檢功能,檢測主機,功放狀態(tài),揚聲器線路的實時檢測。具有接口,監(jiān)聽不同回路揚聲器工作狀態(tài)。/r/n二〕、/r/n/r/n背景音樂和公共播送功能描述:/r/n/r/n1)/r/n系統(tǒng)根本功能:正常情況下,設(shè)置在各個背景音樂分區(qū)的揚聲器既可以分區(qū)播放背景音樂,也可以通過麥克風直接播送講話等內(nèi)容。/r/n/r/n當/r/n超市/r/n內(nèi)有火警等突發(fā)事故時,系統(tǒng)能夠通過自動和手動將背景音樂切換到消防播送,并能聯(lián)動地在相應(yīng)的消防區(qū)域播放消防疏導(dǎo)等信息,指揮/r/n超市/r/n內(nèi)人員疏散,而不影響其他區(qū)域的播音情況。/r/n/r/n2)/r/n系統(tǒng)配置/r/n/r/n/r/n播送系統(tǒng)的控制中心由控制主機、功放機組、數(shù)字播送接收模塊、雙卡座磁帶錄音機、/r/nCD/r/n多盤激光唱機、播送切換器、直接播送用麥克風等組成。另外通過呼叫站接收消防呼叫信息,而用數(shù)字口信模塊存儲消防疏導(dǎo)信息。/r/n/r/n由微處理機控制,背景音樂、消防播送及日常播送合三為一,平時做背景音樂或臨時通知,發(fā)生火災(zāi)時,進行緊急播送。/r/n/r/n每個功放具有/r/n2/r/n路音源輸入,一路為音樂通道,音源為/r/nCD/r/n、雙卡機及數(shù)字播送接收模塊。另一路為優(yōu)先播送通道,音源為呼叫站、麥克風,當優(yōu)先播送通道有信號時,可使音樂信號自動消聲,播放播送。/r/n/r/n/r/n各層播送線由控制中心單獨配線,回路的閉合、斷開由輸出回路控制器控制。根據(jù)消防標準要求,火災(zāi)報警確認后,由火災(zāi)報警控制器聯(lián)動消防播送設(shè)備工作及自動接通著火層及相鄰二層共三層播送線路。/r/n/r/n/r/n由于該系統(tǒng)有消防播送和背景音樂播送的雙重功能,所以要兼顧消防標準和背景音樂的要求,根據(jù)大賣場的實際情況,宜按/r/n6/r/n-8/r/n米/r/n間距布放揚聲器,揚聲器設(shè)置于公共場所的走廊、電梯門廳、公眾衛(wèi)生間、門廳入口處、地下車庫等處。/r/n所有設(shè)備都采取模塊化結(jié)構(gòu)形式,一旦有某個模塊發(fā)生故障,可以很容易地將其撤除或替換,而不至影響整個系統(tǒng)/r/n/r/n。/r/n〔/r/n四/r/n〕/r/n防雷接地系統(tǒng)/r/n1〕、本工程的防雷屬于二類防雷等級,建筑物的防雷裝置同時滿足防直雷擊、側(cè)擊雷設(shè)施。/r/n人防地下室采用TN-S接地保護系統(tǒng)。人防地下室采用一個接地系統(tǒng),戰(zhàn)時總接電阻應(yīng)不大于1歐。戰(zhàn)時的接地總線利用防護區(qū)內(nèi)的平時接地線.戰(zhàn)時使用的電子,電氣設(shè)備應(yīng)在轉(zhuǎn)換時限內(nèi)加裝氧化鋅避雷。/r/n2〕、接閃器:在屋/r/n面/r/n采用4*25熱鍍鋅扁鋼/r/n暗敷/r/n作避雷帶,/r/n在女兒墻上采用4*25熱鍍鋅扁鋼明敷作避雷帶,/r/n屋頂避雷帶連接線網(wǎng)格不大于10*/r/n10M/r/n或12*/r/n8M/r/n;明裝接閃器在女兒墻上明裝。/r/n3〕、引下線:利用建筑物鋼筋混凝土或剪力墻中兩根大于/r/n?/r/n16結(jié)構(gòu)主筋通長焊接〔當結(jié)構(gòu)主筋小于/r/n?/r/n16應(yīng)選擇四根〕作引下線,上端與屋面壁雷帶焊接,下端與接地極焊接,其焊長度、焊接質(zhì)量應(yīng)符合國家標準的要求,跨接線的截面不得小于100平方毫米。用作防雷引下線的結(jié)構(gòu)主筋應(yīng)做好明顯的標識,以保證防雷接地系統(tǒng)的可靠連接。/r/n4〕、接地極:為建筑物根底底梁兩側(cè)結(jié)構(gòu)主筋中大于/r/n?/r/n16的兩根鋼筋焊接連通形成的根底接地網(wǎng),無根底梁時埋設(shè)-40*4熱鍍鋅扁鋼將根底內(nèi)主鋼筋及接地線焊接連通形成綜合接地網(wǎng)。/r/n5〕、外露的接地點應(yīng)涂防銹漆,并加掛標志牌,寫明用途。/r/n6〕、等電位連接:建筑物內(nèi)的大型設(shè)備、管道、電纜橋架、電梯軌道等主要金屬物,應(yīng)與接地裝置或等電位帶相連;金屬管道及電纜的金屬外皮,在進出建筑物處就近與接地裝置相連。/r/n(/r/n包括電力電纜/r/n,/r/n電纜/r/n,/r/n煤氣管道信息電纜/r/n,/r/n給排水管道等/r/n)/r/n;電氣、電信豎井內(nèi)的接地干線每/r/n3/r/n層與樓板鋼筋作等電位聯(lián)結(jié)。/r/n7〕、接地遇機械接頭要跨接,跨接用¢12圓鋼。/r/n8〕、根底接地扁鐵和鋼柱底腳螺栓〔兩個螺栓〕可靠連接,以鋼柱作為引上點。屋面以金屬彩板大于或等于/r/n0.5mm/r/n作為接閃器,屋面板檁條以及鋼柱用接地線可靠連接。/r/n二/r/n、給排水局部/r/n〔含消防給水、噴淋/r/n、/r/n泵房、/r/n太陽能熱水/r/n〕/r/n1/r/n〕、施工范圍及流程/r/n:/r/n本工程消防及生活水源均來自市政給水干管,市政引入管處的供水壓力為/r/n0.25Mpa/r/n。由工程周邊/r/n引2/r/n路/r/nDN200/r/n的給水管。每根引入管進入地塊后分設(shè)兩路,一路/r/nDN200/r/n設(shè)閥門、水表及防污隔斷閥,作為本工程生活用水源,一路/r/nDN150/r/n設(shè)閥門、水表及防污隔斷閥后接入室外消防與生活合用的/r/nDN200/r/n環(huán)管;室外消防用水獨立計量,平時閥門關(guān)閉,消防時翻開。/r/n防空地下室戰(zhàn)時以城市自來水作供水水源。/r/n/r/n人防區(qū):/r/n簡洗間、擴散室、防毒通道、密閉通道、濾毒室、人防通風井等處洗消予埋的防爆地漏及排水管〔通到染毒水池〕干廁等房間予埋普通地漏及排水管通過普通污水集水井,以上在底板施工中必須預(yù)埋好。/r/n給水管、排水管在穿越防空維護結(jié)構(gòu)時,應(yīng)在內(nèi)側(cè)安裝設(shè)置防護/r/n銅芯/r/n閥門/r/n,防護閥處應(yīng)有明顯啟閉標志/r/n;在穿越兩個防護單元時應(yīng)在二側(cè)安裝防護/r/n銅芯/r/n閥門/r/n。所有穿人防地下維護結(jié)構(gòu)、密閉墻、防護密閉墻及頂板均需設(shè)置防護密閉套管;在防爆和抗爆要求的區(qū)域均需設(shè)置防爆波地漏,其余為普通地漏/r/n。給水管、與潛污泵連接的排水管均為塑鋼管,/r/n≤/r/n100為絲扣、>100為法蘭或卡箍連接,鍍鋅鋼管與法蘭連接需二次鍍鋅,維護結(jié)構(gòu)以內(nèi)/r/n的重力排水管為給水鑄鐵管,石棉水泥接口。/r/nb、消火栓系統(tǒng)/r/n室外消火栓系統(tǒng)采用低壓制,室外消火栓消防/r/nDN200/r/n管網(wǎng)環(huán)狀布置,在室外總體的適當位置及水泵接合器附近設(shè)有地上式消火栓。室內(nèi)消火栓系統(tǒng)采用臨時高壓/r/n,/r/n在地下一層設(shè)有消防水池及消防水泵房。消防水泵房內(nèi)設(shè)有兩臺室內(nèi)消火栓消防泵/r/n(Q=/r/n20L/r/n/S/r/n,/r/nH=/r/n84m/r/n)/r/n。在屋頂機房內(nèi)設(shè)高區(qū)高位水箱〔/r/n50m3/r/n〕和穩(wěn)壓設(shè)備〔/r/nQ=/r/n1.31L/r/n/S,H=/r/n30.8m/r/n,穩(wěn)壓罐有效容積/r/n150L/r/n)/r/n。/r/nC/r/n、/r/n噴淋系統(tǒng)/r/n自動噴淋系統(tǒng)采用臨時高壓/r/n,/r/n在地下一層設(shè)有消防水池及消防水泵房。消防水泵房內(nèi)設(shè)有兩臺噴淋泵/r/n(Q=/r/n105L/r/n/S/r/n,/r/nH=/r/n105m/r/n)/r/n,主泵為/r/nFM/UL/r/n認證的電動泵/r/n,/r/n備用泵為國產(chǎn)消防泵。在屋頂機房內(nèi)設(shè)高區(qū)高位水箱〔/r/n50m3/r/n〕和穩(wěn)壓設(shè)備/r/n(Q=/r/n1.31L/r/n/S,H=/r/n30.8m/r/n,穩(wěn)壓罐有效容積/r/n150L/r/n)/r/n。/r/n報警閥分區(qū)集中設(shè)置/r/n,/r/n設(shè)置獨立的噴淋給水管及報警閥間,每層各防火分區(qū)分設(shè)水流指示器和信號閥,所有控制訊號均傳送至消防控制中心。超市冷庫采用干式噴頭,商業(yè)中庭凈高超過/r/n12m/r/n,采用自動掃描射水高空水炮滅火裝置,系統(tǒng)與自動噴水滅火系統(tǒng)合用噴淋泵,供水管在報警閥前分開。屋頂高位消防水箱供應(yīng)初期用水/r/n室內(nèi)消火栓系統(tǒng)設(shè)三組地上式水泵接合器/r/n,/r/n自動噴淋系統(tǒng)設(shè)置七組地上式水泵接合器。柴油發(fā)電機房設(shè)置水噴霧滅火系統(tǒng),噴水強度/r/n20L/r/n/min.m2/r/n室內(nèi)消火栓消防系統(tǒng)、自動噴水滅火系統(tǒng)管道,管徑/r/n?/r/n>=DN80/r/n時,采用熱軋無縫鋼管及配件內(nèi)外壁熱浸鍍鋅,優(yōu)質(zhì)溝槽式管接頭連接;管徑/r/n<DN80/r/n時,采用內(nèi)外壁熱浸鍍鋅焊接鋼管及配件,螺紋連接。地下室消防水泵房、濕式報警閥間、屋頂消防水泵房內(nèi)消防管道應(yīng)采用法蘭連接的連接方式。/r/n消火栓消防、自動噴水滅火:除管徑/r/n<DN50/r/n時為截止閥、供水泵和增壓泵進水管用明桿閘板閘閥外,其余均采用明桿閘板閘閥或帶有鎖定裝置的手動蝶閥。連接自動噴水滅火系統(tǒng)報警閥進出口的控制閥及水流指示器入口前的控制閥采用信號閥。所有閥門采用不銹鋼或球墨鑄鐵閥體,銅彈簧及閥桿。/r/nd/r/n、/r/n泵房/r/n施工/r/n:/r/n/r/n1/r/n
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負責。
- 6. 下載文件中如有侵權(quán)或不適當內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 蝦池施工合同范本
- 直播營銷在網(wǎng)紅經(jīng)濟中的價值體現(xiàn)
- 2025江西吉安市吉水縣吉瑞農(nóng)貿(mào)有限公司招聘2人筆試參考題庫附帶答案詳解
- 瀝青購買合同范本
- 煤礦清煤工職業(yè)技能理論考試題庫150題(含答案)
- 班級管理中的環(huán)保教育與思政教育的結(jié)合
- 科技創(chuàng)新中知識產(chǎn)權(quán)的重要性與展望
- 2025年濟鋼集團有限公司校園招聘88人筆試參考題庫附帶答案詳解
- 班主任經(jīng)驗分享如何處理學(xué)生間的矛盾沖突
- 二零二五年度食堂員工年度考核評價合同
- 技術(shù)標編制要求及注意事項
- 部編人教版八年級語文下冊全冊課件
- 3月8日國際婦女節(jié)主題班會致敬了不起的她母愛是生命的搖籃課件
- 2024電動汽車用鋰離子動力電池包和系統(tǒng)電性能試驗方法
- DZT 0447-2023 巖溶塌陷調(diào)查規(guī)范(1:50000)
- 圍擋施工方案裝配式鐵馬
- 同步課件:古代非洲與美洲
- 2024年德州職業(yè)技術(shù)學(xué)院單招職業(yè)適應(yīng)性測試題庫各版本
- 洗煤廠安全規(guī)程培訓(xùn)
- 外陰炎及陰道炎癥課件
- 企業(yè)微信指導(dǎo)手冊管理員版
評論
0/150
提交評論