PLANNINGANDDESIGNOFHYDROELECTRICPOWERPLANTSTRUCTURES水電站規(guī)劃與結(jié)構(gòu)設(shè)計(jì)3

EM1110-2-300130Apr95Chapter5PhysicalSecurity5-1.ProtectionPlanForeveryhydropowerinstallationadetailed,writtenprotectionplanshallbedeveloped,whichwilluseavail-ableresourcesinthemostefficientmanner.Althoughtheprimaryareaofconcernshouldbeprotectionfromterroristthreats,allaspectsofprotectiondesignshouldbeaddressed.(ArecommendedsourceofadviceistheMissouriRiverDivision(MRD),theCorpsTechnicalCenterofExpertiseforProtectionDesign.)a.Typeofprotection.Indeterminingthetypeandextentofphysicalprotectionrequiredataninstallation,thefollowingpertinentfactorsshouldbetakenintoconsiderationintheindicatedsequence.(1)ImportanceofthepowersupplytoNationalSecurity,totheregionalpowerbase,andprojectopera-tionalrequirements.(2)Definitionandanalysisofareatobeprotected,andotherpertinentconsiderationinherenttotheproblemsuchasexistinghazards,eithernaturalorman-made.(Threatsfromthestoredwaterinthereservoir,fromlandslideoravalanche,fromforestorbrushfire,etc.)(3)Operation,maintenance,andotherrequirementswhichmustbeintegratedintothesecurityplan.(4)Environment-political,economic,legal,surroundingterrain,weatherandclimate.(5)Costsofmaterialandequipmenttobeinstalled,aswellasavailabilityoffundstoprovideatleastmini-mumprotectionforallcriticalareas.(6)Feasibility,personnelandequipmentcosts,andthebestmethodofprovidingadequatecosteffectiveprotection.b.Architecturaldesign.Thearchitecturaldesignofthestructureshouldincorporatenecessarysecuritydesignfeatures.(1)Aminimumofwindows,particularlyneargroundlevel.(2)Wellanchoredsteeldoorsandframes.(3)Transformersandpowertransmissionlineslocated,orprotected,todiscouragethreatactivities.c.Keyelementsindevelopingtheprotectionplan.Theresponseanalysisshouldbeassessed.Thecriticalitemtobeestimatedistheresponsetimeforsecurityforces(projectguards,locallawenforcementagents,etc.)toreachtheinstallationoncetheyarealerted.Thepowerhouseoperatorshouldnotbeconsideredapartofthesecurityforces.Oncetheresponsetimeisestimated,thenathreatanalysisshouldbeperformed.Thiswouldconsiderthemostprobablerouteofintruderstothemostvulnerableareasofthehydropowerinstallation.Thenvariousdelayzones(fences,walls,etc.)shouldbecon-sidered,eachwithitsownintrusiondetectionsystem.Thethreatanalysisshouldresultinaseriesofdelayzonessothatthetotaltimefortheintruderstoreachcriticalareaofthehydropowerinstallations,fromfirstdetection,exceedstheresponsetimebysecurityforces.5-1EM1110-2-300130Apr95Chapter6RetrofittingExistingProjects6-1.GeneralTheadditionofhydropowerfacilitiesattheexistingCorpsofEngineersprojectsmustnotjeopardizethepublicinterestrelativetowatercontrolmanagementforfloodcontrol,navigation,watersupply,waterquality,recreationandotherprojectproposes.Inaddition,thoseaspectsofthedesignthatcouldaffectthesafetyoftheprojectmustbeconsistentwithCorpsstandardsastorequirementsofthismanualandallreferencedmanualsandregulations.Toensurecompliancewiththispolicywhendevelopmentisbynon-federallicenses,theCorpsofEngineerswillreviewandapprovetheproposeddetaileddesignanalysisandplansandspecificationsforthosehydraulic,structuralandmechanicalfeaturesthatcouldaffecttheintegrityandsafetyofthetotalproject.Majoritemsofconcern,butnotnecessarilylimitedto,arediscussedasfollows:6-2.HydraulicDesignConsiderationsa.Proposals.Proposalstoaddhydropowerfacili-tiesatCorpsofEngineersprojectsmustthoroughlyaddressthehydraulicdesigndetailsandtheoverallfunc-tionalcapability.Itemsthatmustbeaddressedincludethefollowing.(1)Streamliningofentrancetopowerpenstockfromfloodcontrolconduitmustbeaddressed.(2)Streamliningtoprecludecavitationinfloodcon-trolconduitatjunctionswithpenstockorgateslotsmustbeaddressed.(3)Positiveandnegativepressuresurgesduetopowerhouseloadrejections,loadacceptance,andunitrunawayisanotherimportantitemtoaddress.(4)Reassessmentofwaterqualityprovisionstoincludesizeandlocationofmulti-levelintakesandcom-patibilityofpowerhousereleaserequirementswithwaterqualityrequirementsisanimportantitem.(5)Meansofdewateringpowerfacilitieswithoutinterruptingwaterqualityand/orfloodcontrolreleasesmustbeaddressed.However,somepowerhouseswithlongpenstocks,orthosewithonlygatesorvalvesimme-diatelyupstreamofthepowerplantneednotbedewateredexceptunderemergencyconditions.Thisprocedurecanbefollowedonlyifitdoesnotimpactupondamsafetyoffloodcontrolregulations.Thistypeofpenstockcanbeinspectedusingdiversorremotelyoperatedcameras.(6)Effectsofaddingtrashracksintheexistingintakeifrequiredforequipmentprotectionmustbeaddressed.b.Submittals.SubmittalsproposinginclusionoradditionofhydropowercombinedwithwaterqualityandorfloodcontrolfacilitiesatCorpsofEngineersprojectsmustincludeahydraulicdesignanalysiscoveringalloperatingandemergencyconditions.Presentationsneedtoaddressallitemsdiscussedabove.Informationonenergyandpressuregradelinesthroughoutthehydraulicpassagescoveringmaximumandminimumconditionswithlocalpressuredropsatsuchplacesasbends,junc-tions,transitions,gateslots,etc.,isnecessary.Thepre-sentationsmustincludeananalysisoftheeffectsofapowerhouseloadrejection.Thedegreeofdetailistobesufficientforthestudystagebeingpresented,althoughatfinaldesignstage.atransientanalysisutilizingstate-of-the-artcomputerprogramsmustbeperformedandreviewedbyaDesignCenter.Therequirementsapplytoproposalsfromothers(tobeaccomplishedattheirexpense)aswellastoin-houseproposals.c.Penstocks.Theexistingregulatingoutletconduitsofferanavailableconnectionbetweenthereservoirandpotentialhydropowerfacilities.Regulatingoutletcon-duitsarfloodcontrolorothernon-powerprojectsareusuallydesignedfornon-pressurized(openchannel)flowconditions.forthemostpart,theseconduitsareofrein-forcedconcretedesignedtowithstandexternalrockorembankmentloadsandexternalhydrostaticpressures.Oncehydropowerfacilityisconnected,theprimarystruc-turalconcernisthatanexistingregulatingoutletconduitbecomesapowerpenstocksubjecttointernalpressuresequaltofullpoolplusanytransientpressuresduetowatermannereffects.SubmittalsproposinginclusionoradditionoffacilitiesatCorpsofEngineersprojectsmustincludestructuralandgeotechnicalanalysiscoveringalloperatingandemergencyconditions.Presentationsneedtoaddressallitemscoveredinthisguidance.Thedegreeofdetailpresentedshouldbesufficientforthestudystagebeingpresented.Thisappliestoproposalsfromothers(tobeaccomplishedattheirexpense)aswellastoin-houseproposals.Thefollowingparagraphspresentacceptabledesigncriteriaforconvertingregulatingoutletconduitstopowerpenstock(downstreamcontrol).6-1EM1110-2-300130Apr956-3.GeotechnicalConsiderationsOriginalgeologicconditionsuponwhichprojectdesignwasbased,anduponwhichcutandcoverorlinesorunlinedtunnelswereconstructed,mustbeknownsothatsafetyandoriginaldesignbenefitsarenotreduced.Watermustnotbeallowedtoescapeintothedamabut-mentsfrompressurizedtunnelstocauseslopestabilityproblemsorgroundwaterchangesthatmightaffectthedam.Aninvestigationofgeologicconditionsrelativetothedesignproposedforapressurizedtunnelmustbemade.Existinglinedtunnelsmayconcealvoids,shearzones,rockoflowdeformationmodulus,etc.Whenmodifyingexistinglinedtunnels,designshallrecognizeandprovidefortheabovepossibilities,justasitwouldforunlinedtunnelscontaininggeologicweaknesses.Fulllengthgroutingbehindliningsorothermeasuresmaybenecessary.Ifanexistingtunnelisactingasadrainagefeatureinanabutment,intentionallyorunintentionally,thepossibilityofgroundwaterpressurechangesoccurringaftermodificationshouldbeevaluated.Thefunctionandmanyofthedetailsofconstructionanderectionforanintegrallyembeddedsteellineraresimilartoafree-standingpenstock;however,theloadingconditionsaredifferent.Thesteellining,concreteencasement,andifpresent,thesurroundingrockacttogethertoresistthepressures.EM1110-2-2901outlinesindetailtheloadingconditionsandallowablestressesforaconduitunderembankmentsorrock.Inbothinstances,externalpres-suresmustbeaccountedfroaswellastheinternalpressures.6-4.TunnelsinRockAbutmentsAnexistingoutlettunnel(unlinedorlinedwithotherthansteel)shouldbeinvestigatedtodeterminetowhatextentthetunnelshouldbelinedwithsteelplatetopre-ventleakagethatcouldpresentadangertothedamorabutment.Theextentofsteellinerplateshouldbesuffi-cienttopreventleakagealongrockfissuresorjointsthatinterceptthedamordownstreamoftheimperviouszone.Anexistingtunnellinermustbeinvestigatedforinternalpressuresthatwilloccuroncethehydropowerfacilityisinstalled.Inregionsofanexistingregulatingoutlettunnellinerwheretherockcoverisinsufficienttooffsetinternalpressures,orwheregeologicweaknessesexist,anewlinermayberequiredfrostructuralreasons.Asteellinerplatecouldbegroutedinplaceanddesignedascompositewithanexistingconcreteliner,providedtheexistinglinerreinforcementisadequateforallloads(seeEM1110-2-2901).Ifthetunnelisunlinedofiftheexistinglinerreinforcementisinadequate,aseparatefree-standingpenstockornewreinforcedconcretelinerwithcompositesteellinerplateshouldbeprovided.6-5.CutandCoverConduitsa.General.Initsexistingnon-pressurizedcondi-tion,theseconduitsaregenerallyreinforcedconcretestructureswithoutsteelplateliners.Topreventleakagethatwouldendangertheembankmentdam,asteelliningisrequiredfromtheupstreamfaceoftheimperviouszonetothepowerhouse.Areinforcedconcretelinercompositesteellinerplate,orafree-standingpenstock,mayberequiredtostructurallyaccommodatetheinternalfullpoolpressuresresultingfromdownstreamcontrolplusadditionalpressuresduetowaterhammereffects.b.Circularconduits.AsteellinergroutedtobeintegralwiththeexistingconcretelinermaybeusedprovidedtherequirementsofEM1110-2-2901aremet.Iftheexistingconcretereinforcementdoesnotmeettheaboverequirements,afree-standingtypepenstockornewreinforcedconcretelinerwithcompositesteellinerplateshouldbeprovided.c.Non-circularconduits.Afree-standingpenstock,erectedwithinandindependentoftheexistingregulatingoutletconduit,shouldbeprovided.6-6.Free-StandingPenstocksWithinConduitsFree-standingpenstocksconstructedwithinanexistingconduitshallbedesignedinaccordancewithpara-graph4-16,penstocksandsurgetanks.Platesandjointsshouldbedesignedforfullpressureduetostaticheadpluswaterhammeraswellasanynegativepressuresdevelopedbyhydraulictransients.Alljointsshouldbeweldedexceptfortheconnectionofthepenstocktothespiralcase,whichisnormallyaflexibletype.Free-standingpenstocksshouldbeconstructedsoastopermitanyleakagetodraintotailwaterwithoutpressurizingthesurroundingregulatingoutletconduit.Carefulattentionshouldbegiventoanchorageofthepenstockagainstlongitudinalthrust.a.Gatesandvalves.Theadditionofhydropowerfacilitiesmustincludeprovisionsforisolatingthepower-plantsoasnottointerferewiththeprojectoriginalpur-pose.Whentheexistingfloodcontrolconduitismodifiedforpenstockuse,aclosuredevicesuchasabutterflyorsphericalvalveoragatemustbeprovidedatthepowerhouseendofthepenstockforshutoffofflow6-2EM1110-2-300130Apr95duringemergencyclosureorduringnormalmaintenanceoftheequipment.(1)Theclosuredeviceshouldbedesignedformaxi-mumpenstockheadincludingwaterhammerandhydrostaticallytestedfor150percentofthemaximumdesignconditions.Thevalveoperatormustbecapableofclosingthedeviceinfrom2to5minutesaspracticalforitssize.Theclosurecapabilitymustbeachievablewithoutoutsidepower.Thus,anenergystoragedevicesuchasanaccumulatororcounterweightisrequired.(2)Theclosureofthenormalwaterpassageatthedownstreamendfordivertingflowtotheturbineissub-jecttothespecificprojectlayout.Gatesorvalvesusedforthispurposemustbedesignedforthemaximumwaterpressure,includingwaterhammer,andsubjecttohydrostatictestinginplace.b.Vents.Whentheexistingfloodcontrolfacilitiesareutilizedforhydropowerpurposes,alltheexistingcomponentsrequirecarefulanalyzingandinvestigationforanyadversecavitationorstructuraleffects.Onesuchitemsubjecttostructuralloadinggreaterthanoriginallythoroughanalysisoftheeffectssuchchangeswouldhaveonthesystemwhenusedintheoriginaloperationmodefortheprojectpurpose.Duringpowerhouseoperationtheventsaresubjecttofullhydrostaticpressureincludingwaterhammer,andthereforestructuraladequacyshouldbethoroughlyinvestigatedforthisconditionaswellastheseismiccondition.c.Bifurcation.Inmostinstances,theutilizationoftheexistingregulatingconduitrequiresdivertingthewaterflowfromtheconduittothepowerproducingfacilities.Themethodofaccomplishingthisobjectiverequiresabifurcationordivertingboxdependingofthespecificsiteconditions.Themethodchosenmustbethoroughlyanalyzedforpotentialcavitationorstructuraleffectsandmayrequiremodeltestingtoverifythedesign.Forfurtherstructuralrequirements,seeparagraph4-16e.6-3EM1110-2-300130Apr95AppendixAReferencesA-1.RequiredPublicationsTM5-809-1LoadAssumptionsforBuildingsTM5-809-10SeismicDesignofBuildingsTM5-810-1MechanicalDesign,HVACER1110-2-109HydroelectricDesignCenterER1110-2-1454Non-FederalHydropowerER1110-2-1806EarthquakeDesignandAnalysisforCorpsofEngineersDamsEM1110-2-1902StabilityofEarthandRockfillDamsEM1110-2-2000StandardPracticeforConcreteEM1110-2-2104StrengthDesignforReinforced-ConcreteHydraulicStructuresEM1110-2-2105DesignofHydraulicSteelStructuresEM1110-2-2200GravityDamDesignEM1110-2-2502RetainingandFloodwallsEM1110-2-2901TunnelsandShaftsinRockEM1110-2-2906DesignofPileFoundationsEM1110-2-3506GroutingTechnologyEM1110-2-4203DesignDataforPowerhouseCranesEM1110-2-4205HydroelectricPowerPlantMechanicalDesignETL1110-2-256SlidingStabilityforConcreteStructures(ETLsaretemporarydocumentsandsubjecttochange)ETL1110-2-301InterimProceduresforSpecifyingEarthquakeMotionsETL1110-2-303EarthquakeAnalysisandDesignofConcreteGravityDamsCE-1602DamGantryCranesCE-1603DraftTubeGantryCranesCE-1604.01IndoorElectricallyOperatedTravelingCranesCE-1604.02IndoorElectricallyOperatedTravelingCranesCE-4000Lump-SumContractforDesignofHydroelectricP

溫馨提示

  • 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。

評(píng)論

0/150

提交評(píng)論