版權(quán)說(shuō)明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡(jiǎn)介
1、大泥窩河過(guò)水箱涵模板與支架施工專項(xiàng)方案 第 - 1 - 頁(yè) 共 41 頁(yè)目 錄一、工程概況 ··········································
2、183;·················································
3、183;···············2二、編制依據(jù) ·································
4、··················································
5、·························3三、施工計(jì)劃 ·······················
6、3;·················································
7、3;··································3四、施工工藝技術(shù) ··············
8、··················································
9、····································4五、施工安全保證措施 ············
10、··················································
11、·····························13六、勞動(dòng)力計(jì)劃 ···················
12、183;·················································
13、183;·································25七、計(jì)算書 ···············
14、··················································
15、··············································25一、工程概況1、本工程屬于大泥窩河工程中的一
16、個(gè)過(guò)水箱涵(沙文生態(tài)科技產(chǎn)業(yè)園麥架河 截污、防洪及景觀整治工程的一部分 ,位于麥架河治理河段中部,屬于麥架河左 岸一級(jí)支流,與麥架河為界,由麥蘇東路順接上游大泥窩河,下游匯入麥架河 , 樁號(hào) K1+293-K1+302.06,全長(zhǎng) 9.06米,凈跨 10米,凈高 3.5米。底板與頂板為 100cm 厚的 C40鋼筋混凝土, 頂板兩側(cè)下底倒角 120cm*40cm, 墻身為 90cm 厚的 C40鋼筋混凝土,墊層為 20cm 厚的 C15素混凝土。 平面圖及橫斷面圖如下:橫 斷 面 圖 (單 位 :cm20厚 C15素 砼C40鋼 筋 砼120*40120*40過(guò) 水 箱 涵 平 面 圖 (單
17、位 :cm 90厚 側(cè) 墻90厚 側(cè) 墻流 水 方 向N2、參建單位如下:建設(shè)單位:貴陽(yáng)高科開(kāi)發(fā)建設(shè)有限公司設(shè)計(jì)單位:中國(guó)市政工程西南設(shè)計(jì)研究總院 地勘單位:深圳勘察研究院有限公司 監(jiān)理單位:北京燕波工程管理有限公司 施工單位:太平洋建設(shè)集團(tuán)有限公司二、編制依據(jù)1、施工圖設(shè)計(jì)文件及地勘報(bào)告;2、中華人民共和國(guó)住房和城鄉(xiāng)建設(shè)部 -建質(zhì)【 2009】 87號(hào)文件;3、中華人民共和國(guó)住房和城鄉(xiāng)建設(shè)部 -建質(zhì)【 2009】 254號(hào)文件;4、 城市橋梁工程施工與質(zhì)量驗(yàn)收規(guī)范 CJJ2-2008;5、 扣件式鋼管腳手架安全技術(shù)規(guī)范 JGJ130-2011;6、 鋼管滿堂支架預(yù)壓規(guī)程 JGJ/194-20
18、09;7、 混凝土結(jié)構(gòu)工程施工規(guī)范 GB50666-2011;8、 建筑施工模板安全技術(shù)規(guī)范 JGJ-2008;9、 鋼管腳手架扣件 (GB 15831 ;9、其他相關(guān)規(guī)范。三、施工計(jì)劃待做(包括進(jìn)度計(jì)劃、材料與設(shè)備計(jì)劃等四、施工工藝技術(shù)1、箱涵施工流程圖 2、箱涵涵身施工要點(diǎn)箱涵涵身豎向施工施工分 2個(gè)階段, 第一階段澆筑至底板內(nèi)壁以上 30cm ; 第二 階段澆筑剩余部分, 2次澆筑的接縫應(yīng)保證有良好的銜接面(粗糙、干凈并不得有 堆落的混凝土和砂漿 。(1 鋼 管滿堂支架搭設(shè) 平面圖及培面圖如下: 鋼 管 滿 堂 支 架 平 面 圖 (單 位 :cm 2590909038B-B剖 面 圖
19、(單 位 :cm木本工程支架擬用扣件式鋼管滿堂腳手架,鋼管采用 48×2.5mm ,模板支架搭 設(shè)高度為 3.5m , 立桿的縱距 b=0.50m、橫距 l=0.50m、步距 h=0.90m??v、 橫向桿及立桿用扣件式鋼管連接。本工程支架搭設(shè)高度未超過(guò) 4米,可以不設(shè)剪刀撐,但 在橫橋方向兩端各設(shè)兩二道加固斜撐, 如圖 A-A 剖面所示。在縱橋方向兩端各設(shè)一 道加固斜撐,如圖 B-B 剖面所示。距離地面 20cm 設(shè)置縱橫掃地桿。支架立桿頂端 用可調(diào) U 型頂托相接, 頂托桿直徑 36mm , 桿長(zhǎng) 60cm , 桿插入鋼管 355cm , 外露 25cm 。 立桿頂層水平桿中心線至
20、托撐頂面長(zhǎng)度 a 為 0.35米(不大于 0.5米 。頂托上設(shè)二 層肋梁:下肋梁為縱向采用 2*48×2.5mm 鋼管, 間距 50cm (如圖 A-A 剖面所示 ; 上肋梁為橫向方木 5 cm(寬×10cm (高 (如圖 B-B 所示 ,間距 20cm 。注:由于上肋梁采用橫向方木,為了讓頂板底模整體性良好,加之頂板橫向 水平段只有 7.6米寬,所以本工程不設(shè)橫向起拱。只在頂板鋼筋的保護(hù)層上起拱, 即頂板鋼筋底筋保護(hù)層在水平段兩端為 3cm 厚,中間為 5cm 厚;反之,頂板鋼筋面 筋保護(hù)層在水平段兩端為 5cm 厚,中間為 3cm 厚。(2箱涵頂板底模、腹板側(cè)模安裝模板
21、安裝前,先由測(cè)量放出腹板的邊線和橋的中軸線,并用墨斗彈出邊、軸 墨線,放樣后經(jīng)監(jiān)理檢查,合格后安裝模板。箱涵頂板底模、腹板側(cè)模采用 15mm 厚木膠合板做面板,箱涵腹板模板支撐體 系內(nèi)楞采用 10cm ×10cm 方木,間距 20cm 、 外楞采用 2*48×2.5mm 及 14對(duì)拉螺 栓,間距 40×40cm 。 ,采用止水型對(duì)拉螺栓平衡側(cè)模板受力。機(jī)械配合人工進(jìn)行模 板安裝。(3箱涵四周施工腳手架搭設(shè)在箱涵四周設(shè)置雙排腳手架,采用單立桿,搭設(shè)高度為 6.0m ,立桿的縱距 1.20米、橫距 0.8米、步距 1.20米,內(nèi)排架距離結(jié)構(gòu) 0.30米。鋼管類型為 4
22、8×2.5,腳 手板采用竹笆片,欄桿采用竹笆片,腳手板下大橫桿在小橫桿上面。地基為粘土地基,壓實(shí)后滿鋪 5cm 厚的木板。(4支架預(yù)壓根據(jù)要求,支架架設(shè)后應(yīng)進(jìn)行預(yù)壓。本工程在頂板模安裝好以后進(jìn)行預(yù)壓,根 據(jù)鋼管滿堂支架預(yù)壓技術(shù)規(guī)程 JG/T194 2009的規(guī)定,預(yù)壓重量為頂板鋼筋混 凝土自重的 1.1倍。由于貴陽(yáng)市場(chǎng)上沒(méi)有 48×2.5鋼管,本工程只能用 48×2.5鋼管代替(這種鋼管是目前貴陽(yáng)市場(chǎng)上同直徑壁厚最厚的鋼管,且其他大部分工程 也是用這種鋼管。為了提高安全系數(shù),本工程擬用預(yù)壓系數(shù)為 1.5倍的頂板鋼筋 混凝土自重。 預(yù)壓材料擬采用堆載鋼材(捆裝鋼筋
23、,模擬箱梁設(shè)計(jì)斷面布載。支架預(yù)撓 度設(shè)置按施工設(shè)計(jì)中彈性變形的計(jì)算和預(yù)壓過(guò)程的實(shí)測(cè)撓度數(shù)值綜合考慮后進(jìn)行 設(shè)置。預(yù)壓分為 3級(jí)進(jìn)行,依次施加荷載為預(yù)壓總荷載的 60%、 20%、 20%。 測(cè)點(diǎn)布置本工程在頂板底模上平均、對(duì)稱布置 20個(gè)測(cè)點(diǎn)。 預(yù)壓監(jiān)測(cè)A 、加載之前測(cè)出各點(diǎn)標(biāo)高 ho 、每級(jí)加載之后測(cè)出各點(diǎn)標(biāo)高 hj 、加載后間隔 24小時(shí)測(cè)出各點(diǎn)標(biāo)高 hi 、卸載 5小時(shí)后測(cè)出各點(diǎn)標(biāo)高 hc 。B 、 預(yù)壓驗(yàn)收滿足各測(cè)點(diǎn)沉降量平均小于 1mm 或連續(xù)三次各測(cè)點(diǎn)沉降量平均量累 計(jì)小于 5mm 時(shí)為合格。(5箱涵普通鋼筋的施工嚴(yán)格按有關(guān)技術(shù)規(guī)范認(rèn)真施工,材料進(jìn)場(chǎng)后經(jīng)嚴(yán)格檢 驗(yàn)合格后加工下料、制
24、作和綁扎。(6現(xiàn)澆箱涵砼采用商品砼,用攪拌車運(yùn)至現(xiàn)場(chǎng)澆筑再用臂架泵將砼泵入模。(7箱涵砼澆筑完畢,表面收漿后即開(kāi)始對(duì)砼灑水養(yǎng)生,養(yǎng)護(hù)采用覆蓋土工布 灑水保濕的養(yǎng)護(hù)方法,養(yǎng)護(hù)時(shí)間不少于 14天。(8模板和支架的拆除內(nèi)側(cè)模及外側(cè)模板應(yīng)在同步養(yǎng)護(hù)的砼試塊強(qiáng)度達(dá) 75%時(shí)方可拆除, 箱梁底模及支 架必須在砼強(qiáng)度達(dá)到設(shè)計(jì)強(qiáng)度的 100%后方可拆除。支架、側(cè)模和底模采用人工拆 除。拆除時(shí)模板和支架分類堆放整齊且及時(shí)運(yùn)回倉(cāng)庫(kù)。3、箱涵模板與支架施工技術(shù)要求(1模板安裝模板安裝前必須做好下列安全技術(shù)準(zhǔn)備工作:應(yīng)審查模板結(jié)構(gòu)設(shè)計(jì)與施工說(shuō)明書中的荷載、計(jì)算方法、節(jié)點(diǎn)構(gòu)造和安全措 施,設(shè)計(jì)審批手續(xù)應(yīng)齊全。應(yīng)進(jìn)行全面
25、的安全技術(shù)交底, 操作班組應(yīng)熟悉設(shè)計(jì)與施工說(shuō)明書, 并應(yīng)做好 模板安裝作業(yè)的分工準(zhǔn)備。應(yīng)對(duì)模板和配件進(jìn)行挑選、檢測(cè),不合格者應(yīng)剔除,并應(yīng)運(yùn)至工地指定地點(diǎn) 堆放。備齊操作所需的一切安全防護(hù)設(shè)施和器具。模板安裝構(gòu)造應(yīng)遵守下列規(guī)定:模板安裝應(yīng)按設(shè)計(jì)與施工說(shuō)明書順序拼裝。豎向模板和支架立桿支承部分安裝在基土上時(shí),應(yīng)加設(shè)墊板,墊板應(yīng)有足夠 強(qiáng)度和支承面積,且應(yīng)中心承載?;翍?yīng)堅(jiān)實(shí),并應(yīng)有排水措施。對(duì)濕陷性黃土應(yīng) 有防水措施;對(duì)特別重要的結(jié)構(gòu)工程可采用混凝土、打樁等措施防止支架柱下沉。 對(duì)凍脹性土應(yīng)有防凍融措施。本工程支架與模板直接著力于箱涵鋼筋砼底板,支承 面有足夠的強(qiáng)度。模板及其支架在安裝過(guò)程中,必須
26、設(shè)置有效防傾覆的臨時(shí)固定設(shè)施?,F(xiàn)澆鋼筋混凝土梁、板,當(dāng)跨度大于 4m 時(shí),模板應(yīng)起拱;當(dāng)設(shè)計(jì)無(wú)具體要 求時(shí),起拱高度宜為全跨長(zhǎng)度的 1/10003/1000,本工程在頂板鋼筋上起拱。 施工時(shí), 在已安裝好的模板上的實(shí)際荷載不得超過(guò)設(shè)計(jì)值。 已承受荷載的支 架和附件,不得隨意拆除或移動(dòng)。安裝模板時(shí),安裝所需各種配件應(yīng)置于工具箱或工具袋內(nèi), 嚴(yán)禁散放在模板 或腳手板上;安裝所用工具應(yīng)系掛在作業(yè)人員身上或置于所配帶的工具袋中,不得 掉落。吊運(yùn)模板時(shí),必須符合下列規(guī)定:作業(yè)前應(yīng)檢查繩索、卡具、模板上的吊環(huán),必須完整有效,在升降過(guò)程中應(yīng) 設(shè)專人指揮,統(tǒng)一信號(hào),密切配合。吊運(yùn)散裝模板時(shí),必須碼放整齊,待捆
27、綁牢固后方可起吊。 嚴(yán)禁起重機(jī)在架空輸電線路下面工作。 5級(jí)風(fēng)及其以上應(yīng)停止一切吊運(yùn)作業(yè)。腹模板應(yīng)符合下列規(guī)定:當(dāng)用散拼定型模板支模時(shí), 應(yīng)自下而上進(jìn)行, 必須在下一層模板全部緊固后, 方可進(jìn)行上一層安裝。當(dāng)下層不能獨(dú)立安設(shè)支撐件時(shí),應(yīng)采取臨時(shí)固定措施。 當(dāng)采用預(yù)拼裝的大塊墻模板進(jìn)行支模安裝時(shí),嚴(yán)禁同時(shí)起吊兩塊模板,并應(yīng) 邊就位、邊校正、邊連接,固定后方可摘鉤。模板未安裝對(duì)拉螺栓前,板面應(yīng)向后傾一定角度。安裝過(guò)程應(yīng)隨時(shí)拆換支撐 或增加支撐。對(duì)拉螺栓與腹模板應(yīng)垂直,松緊應(yīng)一致,腹厚尺寸應(yīng)正確。腹模板內(nèi)外支撐必須堅(jiān)固、可靠,應(yīng)確保模板的整體穩(wěn)定。當(dāng)腹模板外面無(wú) 法設(shè)置支撐時(shí), 應(yīng)于里面設(shè)置能承受拉
28、和壓的支撐。 多排并列且間距不大的腹模板, 當(dāng)其支撐互成一體時(shí),應(yīng)有防止灌筑混凝土?xí)r引起臨近模板變形的措施。(2 模板拆除模板的拆除措施應(yīng)經(jīng)技術(shù)主管部門或負(fù)責(zé)人批準(zhǔn), 拆除模板的時(shí)間可按現(xiàn)行 國(guó)家標(biāo)準(zhǔn) 混凝土結(jié)構(gòu)工程施工規(guī)范 GB50666-2011的有關(guān)規(guī)定執(zhí)行。 冬期施工的 拆模,應(yīng)遵守專門規(guī)定。當(dāng)混凝土未達(dá)到規(guī)定強(qiáng)度時(shí), 如需提前拆模, 必須經(jīng)過(guò)計(jì)算和技術(shù)主管確認(rèn) 其強(qiáng)度能足夠承受此荷載后,方可拆除。大體積混凝土的拆模時(shí)間除應(yīng)滿足混凝土強(qiáng)度要求外, 還應(yīng)使混凝土內(nèi)外溫 差降低到 25°以下時(shí)方可拆模。否則應(yīng)采取有效措施防止產(chǎn)生溫度裂縫。拆模前應(yīng)檢查所使用的工具應(yīng)有效和可靠, 扳
29、手等工具必須裝入工具袋或系 掛在身上,并應(yīng)檢查拆模場(chǎng)所范圍內(nèi)的安全措施。模板的拆除工作應(yīng)設(shè)專人指揮。 作業(yè)區(qū)應(yīng)設(shè)圍欄, 其內(nèi)不得有其它工種作業(yè), 并應(yīng)設(shè)專人負(fù)責(zé)監(jiān)護(hù)。拆下的模板、零配件嚴(yán)禁拋擲。拆模的順序和方法應(yīng)按模板的設(shè)計(jì)規(guī)定進(jìn)行。當(dāng)設(shè)計(jì)無(wú)規(guī)定時(shí),可采取先支 的后拆、后支的先拆、先拆非承重模板、后拆承重模板,并應(yīng)從上而下進(jìn)行拆除。 拆下的模板不得拋扔,應(yīng)按指定地點(diǎn)堆放。多人同時(shí)操作時(shí),應(yīng)明確分工、統(tǒng)一信號(hào)或行動(dòng),應(yīng)具有足夠的操作面,人 員應(yīng)站于安全處。高處拆除模板時(shí),應(yīng)遵守有關(guān)高處作業(yè)的規(guī)定。嚴(yán)禁使用大錘和撬棍,操作 層上臨時(shí)拆下的模板堆放不能超過(guò) 3層。在提前拆除互相搭連并涉及其它后拆模板
30、的支撐時(shí),應(yīng)補(bǔ)設(shè)臨時(shí)支撐。拆模 時(shí),應(yīng)逐塊拆卸,不得成片撬落或拉倒。拆模如遇中途停歇,應(yīng)將已拆松動(dòng)、懸空、浮吊的模板或支架進(jìn)行臨時(shí)支撐 牢固或相互連接穩(wěn)固。對(duì)活動(dòng)部件必須一次拆除。(3 、滿堂支架架設(shè)鋼管、扣件材料管理材質(zhì):引用了國(guó)家行業(yè)標(biāo)準(zhǔn) 扣件式鋼管腳手架安全技術(shù)規(guī)范 JGJ130-2011的相關(guān)規(guī)定驗(yàn)收與檢測(cè),采購(gòu)、租賃的鋼管、扣件必須有產(chǎn)品合格證和法定檢測(cè)單位的 檢測(cè)檢驗(yàn)報(bào)告,生產(chǎn)廠家必須具有技術(shù)質(zhì)量監(jiān)督部門頒發(fā)的生產(chǎn)許可證。并且使用 前必須進(jìn)行抽樣檢測(cè)。鋼管外觀質(zhì)量要求:1鋼管表面應(yīng)平直光滑,不應(yīng)有裂縫、結(jié)疤、分層、錯(cuò)位、硬彎、毛刺、壓 痕和深的劃道;2鋼管外徑、壁厚、端面等的偏差;
31、鋼管表面銹蝕深度不得超過(guò)規(guī)定。3鋼管應(yīng)進(jìn)行防銹處理??奂庥^質(zhì)量要求:1有裂縫、變形或螺栓出現(xiàn)滑絲的扣件嚴(yán)禁使用;2扣件應(yīng)進(jìn)行防銹處理。(2技術(shù)資料施工現(xiàn)場(chǎng)應(yīng)建立鋼管、扣件使用臺(tái)帳,詳細(xì)記錄鋼管、扣件的來(lái)源、數(shù)量和質(zhì) 量檢驗(yàn)等情況人員管理(3架體總體要求對(duì)剪刀撐、水平桿、周邊拉結(jié)等采取一系列加強(qiáng)措施。支模架體高寬比:模板支架的整體高寬比不應(yīng)大于 3。 本工程高度比為 0.35 (4架體立柱可調(diào)支托底部的立柱頂端應(yīng)沿縱橫向設(shè)置一道水平拉桿。模板支架必須設(shè)置縱、 橫向掃地桿??v向掃地桿應(yīng)采用直角扣件固定在距底 座上皮不大于 200mm 處的立桿上, 橫向掃地桿亦應(yīng)采用直角扣件固定在緊靠縱向掃 地桿
32、下方的立桿上??奂戒摴芰⒅娱L(zhǎng)嚴(yán)禁搭接,必須采用對(duì)接扣件連接,相鄰兩立柱的對(duì)接 接頭不得在同步內(nèi),且對(duì)接接頭沿豎向錯(cuò)開(kāi)的距離不宜小于 500mm ,各接頭中心距 離主節(jié)點(diǎn)不宜大于歩距的 1/3。 本工程滿堂支架搭設(shè)總高度為 3.5, 立柱無(wú)搭接和對(duì) 接。采用扣件式鋼管立柱時(shí), 嚴(yán)禁將上段的鋼管與下段的鋼管立柱錯(cuò)開(kāi)固定在水 平拉桿上。(5架體水平桿每步的縱、橫向水平桿應(yīng)雙向拉通。搭設(shè)要求:水平桿接長(zhǎng)宜采用對(duì)接扣件連接,也可采用搭接。對(duì)接、搭接應(yīng) 符合下列規(guī)定:1對(duì)接扣件應(yīng)交錯(cuò)布置:兩根相鄰縱向水平桿的接頭不宜設(shè)置在同步或同跨 內(nèi);不同步或不同跨兩個(gè)相鄰接頭在水平方向錯(cuò)開(kāi)的距離不應(yīng)小于 500m
33、m ;各接頭 至最近主節(jié)點(diǎn)的距離不宜大于縱距的確 1/3;2搭接長(zhǎng)度不應(yīng)小于 1m ,應(yīng)等距離設(shè)置 3個(gè)旋轉(zhuǎn)扣件固定,端部扣件蓋板邊緣至搭接水平桿桿端的距離不應(yīng)小于 100mm 。主節(jié)點(diǎn)處水平桿設(shè)置:主節(jié)點(diǎn)處必須設(shè)置一根橫向水平桿,用直角扣件扣 接且嚴(yán)禁拆除。主節(jié)點(diǎn)兩個(gè)直角扣件的中心距不應(yīng)大于 150mm 。(4 滿堂支架拆除拆除腳手架的準(zhǔn)備工作應(yīng)符合下列規(guī)定:應(yīng)全面檢查腳手架的扣件連接、連墻件、支撐體系等是否符合構(gòu)造要求; 應(yīng)根據(jù)檢查結(jié)果補(bǔ)充完善施工組織設(shè)計(jì)中的拆除順序和措施,經(jīng)主管部門批 準(zhǔn)后方可實(shí)施;應(yīng)由單位工程負(fù)責(zé)人進(jìn)行拆除安全技術(shù)交底;應(yīng)清除腳手架上雜物及地面障礙物。拆除腳手架時(shí),應(yīng)
34、符合下列規(guī)定:拆除作業(yè)必須由上而下逐層進(jìn)行,嚴(yán)禁上下同時(shí)作業(yè);卸料時(shí)應(yīng)符合下列規(guī)定:各構(gòu)配件嚴(yán)禁拋擲至地面;運(yùn)至地面的構(gòu)配件應(yīng)按規(guī)范的規(guī)定及時(shí)檢查、 整修與保養(yǎng), 并按品種、 規(guī)格 隨時(shí)碼堆存放。五、施工安全保證措施1、安全防護(hù)措施為杜絕重大事故和人身傷亡事故的發(fā)生,把一般安全事故減少到最低限 度,確保施工的順利進(jìn)行,特制定如下防護(hù)措施:(1貫徹“安全第一,預(yù)防為主”的方針,建立以項(xiàng)目經(jīng)理為組長(zhǎng),專 職安全員、項(xiàng)目副經(jīng)理、項(xiàng)目總工、各工程隊(duì)長(zhǎng)為副組長(zhǎng)的安全生產(chǎn)領(lǐng)導(dǎo)小 組,層層落實(shí),形成健全的安全體系。(2建立健全安全生產(chǎn)管理制度和操作規(guī)程,使安全生產(chǎn)有章可循,有 規(guī)可依。(3 不斷加強(qiáng)安全生產(chǎn)
35、的教育和宣傳, 使全員牢固樹(shù)立安全生產(chǎn)的思想, 提高全員的安全意識(shí)。(4加強(qiáng)對(duì)施工人員的培訓(xùn)工作,定期開(kāi)展各種施工技術(shù)培訓(xùn)。(5施工現(xiàn)場(chǎng)周圍必須配備、架設(shè)并維護(hù)適宜警告、危險(xiǎn)與消防標(biāo)志, 加強(qiáng)對(duì)周圍民眾安全宣傳工作。(6砼攪拌、電工、電焊等重要工種操作人員必須持證上崗,嚴(yán)禁違章 作業(yè),施工時(shí)必須佩帶安全帽。(7開(kāi)挖基坑施工時(shí),須視現(xiàn)場(chǎng)土質(zhì)情況,采取相應(yīng)的支護(hù)措施,防止 土方坍塌事故的發(fā)生。(8施工時(shí)加強(qiáng)各工序之間的協(xié)調(diào)工作,實(shí)行安全員跟班作業(yè)制度。(9施工期間注意安全用電,由專職電工負(fù)責(zé)操作,制訂安全用電、防 火措施,定期進(jìn)行安全檢查。(10利用各種宣傳工具,采取多種教育形式,使職工牢固樹(shù)立“
36、安全 第一”的思想,不斷強(qiáng)化安全意識(shí),建立安全保證體系,使安全管理制度化, 教育經(jīng)?;?。在下達(dá)生產(chǎn)任務(wù)時(shí),必須同時(shí)下達(dá)安全技術(shù)措施。檢查工作時(shí), 必須同時(shí)檢查安全技術(shù)措施執(zhí)行情況??偨Y(jié)工作時(shí),必須同時(shí)總結(jié)安全生產(chǎn) 情況,提出安全生產(chǎn)要求,把安全生產(chǎn)貫穿到施工的全過(guò)程。(11認(rèn)真堅(jiān)持執(zhí)行定期安全教育、安全講話、安全檢查制度,設(shè)立安 全監(jiān)督崗,充分發(fā)揮安全人員的作用,對(duì)發(fā)現(xiàn)的事故隱患和危及工程、人身 安全的事項(xiàng),作到立即處理,做出記錄,限期改正,落實(shí)到人。(12架子作業(yè)人員必須佩戴安全帶并站穩(wěn)把牢,在架子上傳遞 , 放置桿 件時(shí)應(yīng)注意失衡閃失;整體性拉桿應(yīng)隨架子高度的上升及時(shí)安裝 , 以確保整架穩(wěn)
37、定;搭設(shè)中應(yīng)統(tǒng)一指揮 , 協(xié)調(diào)作業(yè);確保支架結(jié)構(gòu)的尺寸。桿件的垂直度和 水平度 , 各節(jié)點(diǎn)構(gòu)造和緊固程度符合施工規(guī)范要求;禁止使用材質(zhì) , 規(guī)格不符 合要求的桿配件。(13起重指揮應(yīng)站在能夠照顧全面的地點(diǎn) , 信號(hào)要統(tǒng)一、準(zhǔn)確;嚴(yán)禁任 何人員在起重臂和吊起的重物下面停留或行走;起重物件應(yīng)使用交互捻制的 鋼絲繩,有打結(jié)、變形、斷絲和銹蝕的鋼絲繩應(yīng)及時(shí)按規(guī)定降低使用標(biāo)準(zhǔn)或 報(bào)廢;起吊物件應(yīng)合理設(shè)置溜繩。(14搭設(shè)腳手架人員必須戴安全帽、系安全帶、穿防滑鞋。在腳手架 上進(jìn)行電、氣焊作業(yè)時(shí),有防火措施和專人看守。(15當(dāng)有六級(jí)以上大風(fēng)和雨天氣時(shí)停止腳手架的搭設(shè)和拆除作業(yè),防 滑鞋作業(yè)。(16支架及腳手
38、架搭設(shè)時(shí)地面設(shè)有圍欄和警戒標(biāo)志,并有專人看守, 嚴(yán)禁非操作人員入內(nèi)。(17支架拆除設(shè)專人指揮,施工人員統(tǒng)一有序進(jìn)行,并配好相應(yīng)的安 裝全防護(hù)用品。2、安全技術(shù)交底(1施工應(yīng)按經(jīng)審批的方案進(jìn)行,方案未經(jīng)審批不得施工。確保底架支 撐穩(wěn)固后,方可上架作業(yè),作業(yè)人員必須佩戴安全帶及安全帽,并在高架橋 兩側(cè)搭設(shè)安全網(wǎng)。只有在確認(rèn)安全網(wǎng)可靠后,方可進(jìn)行上層作業(yè)。應(yīng)通過(guò)設(shè) 在支架外的人員通道上下架子。傳遞和安裝桿件時(shí),要盡量創(chuàng)造安全的作業(yè) 條件,在操作時(shí)要站穩(wěn)把牢,謹(jǐn)防失衡。(2明確支架施工現(xiàn)場(chǎng)安全負(fù)責(zé)人,負(fù)責(zé)施工全過(guò)程的安全管理工作。 在支架搭設(shè)、拆除前向作業(yè)人員進(jìn)行安全技術(shù)交底。未經(jīng)審批部門同意,不 得
39、搭設(shè)和拆除。(3支架施工現(xiàn)場(chǎng)應(yīng)搭設(shè)工作梯,作業(yè)人員不得從支撐系統(tǒng)爬上爬下。(4支架搭設(shè)、拆除和砼澆注期間,無(wú)關(guān)人員不得進(jìn)入支架底下,且由 現(xiàn)場(chǎng)安全員在現(xiàn)場(chǎng)維護(hù)。(5支架搭設(shè)人員必須持證上崗,并戴安全帽,系安全帶、穿防滑鞋。 惡劣天氣時(shí)應(yīng)停止模板支架的搭設(shè)與拆除。雨后上架作業(yè)應(yīng)有防滑措施。 (6整架拼裝完成后,重點(diǎn)檢查以下內(nèi)容:保證架體幾何不變性的斜桿、剪刀撐、十字撐等設(shè)置是否完善; 基礎(chǔ)是否有不均勻沉降,立桿底座與基礎(chǔ)面的接觸有無(wú)松動(dòng)或懸空情 況;立桿上扣件是否可靠鎖緊。(7需要多人配合的操作作業(yè)決不允許一人冒險(xiǎn)作業(yè),多人配合作業(yè)時(shí) 要互相呼應(yīng),協(xié)調(diào)工作。(8支架上人員應(yīng)避免工具和材料的掉落,
40、下面人員應(yīng)避開(kāi)危險(xiǎn)區(qū)域, 隨時(shí)注意觀察,發(fā)現(xiàn)有危險(xiǎn)時(shí)及時(shí)避開(kāi)。在支架上作業(yè)的人員要全神貫注, 并注意適當(dāng)?shù)男菹?避免疲勞作業(yè)。(9身體狀況不適的施工人員,不得上架作業(yè),有癲癇、心臟病、高血 壓等病癥的人員,不允許上架作業(yè)。(10支架上作業(yè)不要進(jìn)行用力過(guò)猛的作業(yè),謹(jǐn)防閃失。(11腳手架使用期間,嚴(yán)禁擅自拆除架體結(jié)構(gòu)桿件,如需拆除必須報(bào) 請(qǐng)技術(shù)主管同意,確定補(bǔ)救措施后放可實(shí)施。(12施工期間隨時(shí)對(duì)支架進(jìn)行全面檢查,發(fā)現(xiàn)異常情況及時(shí)通報(bào),必 要時(shí)采取果斷措施,制止異?,F(xiàn)象的發(fā)生。(13舊鋼管材質(zhì)應(yīng)符合下列規(guī)定:表面銹蝕深度應(yīng)在應(yīng)不超過(guò) 0.18mm鋼管的彎曲變形應(yīng)符合 扣件式鋼管腳手架安全技術(shù)規(guī)范
41、JGJ130-2011的規(guī)定。支架搭設(shè)的技術(shù)要求、允許偏差應(yīng)符合 扣件式鋼管腳手架安全技術(shù)規(guī) 范 JGJ130-2011的要求。(14構(gòu)配件要求 扣 件 式 支 架 用 鋼 管 采 用 符 合 現(xiàn) 行 國(guó) 家 標(biāo) 準(zhǔn) 直 縫 電 焊 鋼 管 (GB/T13793-92或低壓流體輸送用焊接鋼管 (GB/T3092中的 Q235A 級(jí) 普通鋼管,其材質(zhì)性能應(yīng)符合現(xiàn)行國(guó)家標(biāo)準(zhǔn)碳素結(jié)構(gòu)鋼 (GB/T700的規(guī) 定??奂街Ъ苡?鋼管規(guī)格 為 48×2.5mm ,鋼管 壁厚不得小 于 2.5 -0.025mm ??奂街Ъ軜?gòu)件的扣件、可調(diào)底座及可調(diào)托撐螺母應(yīng)采用可鍛鑄鐵或 鑄鋼制造,其材料機(jī)械
42、性能應(yīng)符合 GB9440中 KTH330-08及 GB11352中 ZG270-500的規(guī)定??奂綐?gòu)件的扣件、橫桿接頭、斜桿接頭應(yīng)采用碳素鑄鋼制造,其材 料機(jī)械性能應(yīng)符合 GB11352中 ZG230-450的規(guī)定。采用鋼板熱沖壓整體成形的扣件,鋼板應(yīng)符合 GB700標(biāo)準(zhǔn)中 Q235A 級(jí) 鋼的要求,板材厚度不得小于 5mm 。腳手架采用的扣件,在螺栓擰緊扭力矩達(dá) 65N ·m 時(shí),不得發(fā)生破壞。 腳手架必須設(shè)置縱、橫向掃地桿。縱向掃地桿應(yīng)采用直角扣件固定在 距底座上皮不大于 200mm 處的立桿上。橫向掃地桿亦應(yīng)采用直角扣件固定在 緊靠縱向掃地桿下方的立桿上。當(dāng)立桿基礎(chǔ)不在同一高
43、度上時(shí),必須將高處 的縱向掃地桿向低處延長(zhǎng)兩跨與立桿固定,高低差不應(yīng)大于 1m 。(15腳手架使用中,應(yīng)定期檢查下列項(xiàng)目,對(duì)發(fā)現(xiàn)問(wèn)題及時(shí)整改:桿件的設(shè)置和連接是否符合要求,是否有松動(dòng);地基是否積水,是否有不均勻沉降,底座是否松動(dòng),立桿是否懸空; 立桿扣件是否可靠鎖緊,扣件螺栓是否松動(dòng);立桿連接銷是否安裝、斜桿扣接點(diǎn)是否符合要求、扣件擰緊程度。 立桿的沉降與垂直度的偏差是否符合規(guī)范的規(guī)定;安全防護(hù)措施是否符合要求;(16腳手架搭設(shè)人員必須是經(jīng)過(guò)按現(xiàn)行國(guó)家標(biāo)準(zhǔn)特種作業(yè)人員安全 技術(shù)考核管理規(guī)則考核合格的專業(yè)架子工。上崗人員應(yīng)定期體檢,合格者 方可持證上崗。(17作業(yè)層上的施工荷載應(yīng)符合設(shè)計(jì)要求,不
44、得超載。不得將泵送混 凝土和砂漿的輸送管等固定在支架架上,嚴(yán)禁懸掛起重設(shè)備。模板等不得直 接堆放在支架上。(18不得在模板支撐架和腳手架的基礎(chǔ)及其鄰近處進(jìn)行挖掘作業(yè),否 則應(yīng)采取安全措施,并報(bào)主管部門批準(zhǔn)。(19支架或腳手架應(yīng)與架空輸電線路保持安全距離,工地臨時(shí)用電線 路架設(shè)及腳手架接地防雷措施等應(yīng)按現(xiàn)行行業(yè)標(biāo)準(zhǔn)施工現(xiàn)場(chǎng)臨時(shí)用電安全 技術(shù)規(guī)范 (JGJ461的有關(guān)規(guī)定執(zhí)行。(20搭拆腳手架時(shí),地面應(yīng)設(shè)圍欄和警戒標(biāo)志,并派專人看守,嚴(yán)禁 非操作人員入內(nèi)。(21遇 6級(jí)及以上大風(fēng)、雨雪、大霧天氣時(shí)應(yīng)停止腳手架的搭設(shè)與拆 除作業(yè)。(22使用后的腳手架構(gòu)配件應(yīng)清除表面粘結(jié)的灰渣,校正桿件變形, 表面作
45、防銹處理后待用。3、事故應(yīng)急救援預(yù)案(1 、總則1為認(rèn)真貫徹安全生產(chǎn)法及國(guó)家有關(guān)法令、法規(guī),結(jié)合局生產(chǎn)安全事 故應(yīng)急救援預(yù)案 ,堅(jiān)持“安全第一、預(yù)防為主、綜合治理”的方針,切實(shí)做好防 患工作,在生產(chǎn)安全事故發(fā)生時(shí)能迅速采取正確措施,有效控制事故,最大限度地 減少人員傷亡和財(cái)產(chǎn)損失,特制定本預(yù)案。2本預(yù)案所稱生產(chǎn)安全事故是指在現(xiàn)澆箱涵生產(chǎn)過(guò)程中發(fā)生的, 造成或可能 造成員工生命安全、國(guó)家、企業(yè)財(cái)產(chǎn)損失的事故。根據(jù)現(xiàn)澆箱涵工程的特點(diǎn),項(xiàng)目 部對(duì)本工程施工過(guò)程的危險(xiǎn)源進(jìn)行辨認(rèn)、評(píng)價(jià),共辨識(shí)出重大危險(xiǎn)源六大類,這些 危險(xiǎn)可能造成的危害主要有:高處墜落事故:物體打擊事故:觸電事故:火災(zāi)和爆炸事故:腳手架
46、坍塌事故。3本預(yù)案適用于本項(xiàng)目部范圍內(nèi)發(fā)生的工程建設(shè)三級(jí)及以上重大事故。4本預(yù)案只是針對(duì)在事故發(fā)生后所采取的有效急救措施。(2生產(chǎn)安全事故應(yīng)急救援指揮系統(tǒng)職責(zé)應(yīng)急救援領(lǐng)導(dǎo)小組成員(責(zé)任人名單:組長(zhǎng):馬玉洪,電話組長(zhǎng):常大軍,電話美龍,電話員:宋朝明,電話夫天,電話大林,電話急救援領(lǐng)導(dǎo)小組的職責(zé)負(fù)責(zé)應(yīng)急狀態(tài)下的指揮和協(xié)調(diào)搶救、救護(hù)、后勤服務(wù)及善后處理工作。組織應(yīng)急救援預(yù)案演練,并不斷完善應(yīng)急救援預(yù)案。生產(chǎn)安全事故發(fā)生后,立即啟動(dòng)預(yù)案,統(tǒng)一指揮
47、,實(shí)施應(yīng)急救援的各項(xiàng)工作, 統(tǒng)一調(diào)度人力、物力、財(cái)力,努力將事故的損失降到最底程度;生產(chǎn)事故發(fā)生后,決定搶險(xiǎn)救援技術(shù)措施方案;必要時(shí)向外單位提出救援請(qǐng)求;向上級(jí)單位如實(shí)報(bào)告事故和事故救援情況。聯(lián)絡(luò)員在應(yīng)急狀態(tài)負(fù)責(zé)對(duì)外聯(lián)系、求援、情況報(bào)告、傳達(dá)上級(jí)安全部門的指 揮要求。根據(jù)事故的性質(zhì)和大小, 由應(yīng)急狀態(tài)領(lǐng)導(dǎo)小組組織事故調(diào)查小組和善后處理 小組,對(duì)事故進(jìn)行調(diào)查和善后處理?;虬瓷霞?jí)主管部門安排進(jìn)行實(shí)施。應(yīng)急救援聯(lián)絡(luò)方式領(lǐng)導(dǎo)小組的全體成員在應(yīng)急狀態(tài)下手機(jī) 24小時(shí)開(kāi)通;應(yīng)急救援電話:急救:120 火警:119 交通事故:122(3生產(chǎn)安全事故應(yīng)急救援預(yù)案程序(1生產(chǎn)安全事故發(fā)生以后,事故現(xiàn)場(chǎng)人員應(yīng)當(dāng)立
48、即報(bào)告現(xiàn)場(chǎng)負(fù)責(zé)人,現(xiàn)場(chǎng) 負(fù)責(zé)人應(yīng)立即向安全員或項(xiàng)目部領(lǐng)導(dǎo)報(bào)告,并應(yīng)立即采取有效措施,組織搶救,防 止事故擴(kuò)大,減少人員傷亡和財(cái)產(chǎn)損失。(2應(yīng)急狀態(tài)領(lǐng)導(dǎo)小組接到生產(chǎn)安全事故報(bào)告后,組長(zhǎng)或副組長(zhǎng)指定有關(guān)人 員應(yīng)當(dāng)立即趕赴事故現(xiàn)場(chǎng),組織事故搶救。并指定專人將事故情況報(bào)告上級(jí)主管部 門、業(yè)主、監(jiān)理、當(dāng)?shù)卣鞴懿块T。報(bào)告內(nèi)容:事故發(fā)生的時(shí)間、詳細(xì)地點(diǎn)、事 故類別、簡(jiǎn)要經(jīng)過(guò)、傷亡人數(shù)、直接經(jīng)濟(jì)損失的初步估計(jì)、事故發(fā)生原因的初步判 斷、 事故發(fā)生后采取的措施及事故控制情況、 現(xiàn)場(chǎng)救援所需專業(yè)人員和搶救設(shè)備等。 (3應(yīng)急狀態(tài)領(lǐng)導(dǎo)小組立即啟動(dòng)本預(yù)案,按本預(yù)案分工,迅速救援人員、搶 險(xiǎn)設(shè)備、 物資器材等到達(dá)事故
49、現(xiàn)場(chǎng), 聽(tīng)從現(xiàn)場(chǎng)總指揮, 立即開(kāi)展應(yīng)急搶險(xiǎn)救援工作。 (4應(yīng)急救援措施1概述生產(chǎn)安全事故發(fā)生以后,應(yīng)急救援領(lǐng)導(dǎo)小組決定啟動(dòng)救援預(yù)案后, 各小組負(fù) 責(zé)人及應(yīng)急救援人員迅速到位履行職責(zé)。物資部門應(yīng)配備必要地應(yīng)急救援器材、設(shè)備、進(jìn)行經(jīng)常性的維護(hù)、保養(yǎng),保 證完好狀態(tài),以備隨時(shí)調(diào)用。2各類生產(chǎn)安全事故應(yīng)急救援預(yù)案高處墜落事故應(yīng)急救援預(yù)案當(dāng)發(fā)生高處墜落事故后,立即致電“ 120”急救中心,詳細(xì)報(bào)告事故發(fā)生的地 點(diǎn)及受傷人數(shù)。在急救中心專業(yè)人員未到過(guò)之前,應(yīng)馬上組織搶救傷者,首先觀察傷者的受傷 情況、部位、傷害性質(zhì),如傷員發(fā)生休克,應(yīng)先處理休克。遇呼吸、心跳停止者, 應(yīng)立即進(jìn)行人工呼吸,胸外心臟擠壓。處理
50、休克狀態(tài)的傷員要讓其安靜、保暖、平 臥、少動(dòng),并將下肢抬高約 20度左右,盡快送進(jìn)醫(yī)院搶救治療。出現(xiàn)顱腦損傷,必須維持呼吸道暢通?;杳哉邞?yīng)平臥,面部轉(zhuǎn)向一側(cè),以防舌 根下墜或分泌物、嘔吐物吸入,發(fā)生喉阻塞。有骨折者,應(yīng)初步固定再搬運(yùn)。遇有 凹陷骨折、 嚴(yán)重的顱底骨折及嚴(yán)重的腦損傷癥狀出現(xiàn), 創(chuàng)傷處用消毒的紗布或清潔 布等覆蓋傷口,用繃帶或布條包扎后,及進(jìn)送就看完有條件的醫(yī)院治療。物體打擊事故應(yīng)急救援預(yù)案當(dāng)發(fā)生物體打擊事故后, 搶救的重點(diǎn)放在對(duì)休克、 胸部骨折和出血上進(jìn)行處理。 發(fā)生物體打擊事故后, 應(yīng)馬上組織搶救傷者, 首先觀察傷者的受傷情況、 部位、 傷害性質(zhì),如傷員發(fā)生休克,應(yīng)先處理休克。
51、遇呼吸、心跳停止者,應(yīng)立即進(jìn)行人 工呼吸,胸外心臟擠壓。處于休克狀態(tài)的傷員要讓其安靜、保暖、平臥、少動(dòng),并 將下肢抬高約 20度左右,盡快送醫(yī)院進(jìn)行搶救治療。出現(xiàn)顱腦外傷,必須維持呼吸道通暢?;杳哉邞?yīng)平臥,面部轉(zhuǎn)向一側(cè),以防舌 根下墜或分泌物、嘔吐物吸入,發(fā)生喉阻塞。有骨折者,應(yīng)初步固定后再搬運(yùn)。偶 有凹陷骨折、嚴(yán)重的顱底骨折及嚴(yán)重的腦損傷癥狀出現(xiàn),創(chuàng)傷處用消毒的紗布或清 潔布等覆蓋傷口,用繃帶或布條包扎后,及時(shí)送就近有條件的醫(yī)院治療。發(fā)現(xiàn)脊椎受傷者, 創(chuàng)傷處用消毒的紗布或清潔布等覆蓋傷口, 用繃帶或布條包 扎后。搬運(yùn)時(shí),將傷者平臥放在帆布擔(dān)架或硬板上,以免受傷的脊椎移位、斷裂造 成截癱,招致
52、死亡。搶救脊椎受傷者,搬運(yùn)過(guò)程,嚴(yán)禁只抬傷者的兩肩與兩腿或單 肩背運(yùn)。遇有創(chuàng)傷性出血的傷員,應(yīng)迅速包扎止血,使傷員保持在頭低腳高的臥位,并 注意保暖。正確的現(xiàn)場(chǎng)止血處理措施:a 一般傷口小的止血法:先用生理鹽水(0.9%NaCl溶液沖洗傷口, 涂上紅汞 水,然后蓋上消毒紗布,用繃帶,較緊地包扎。b 加壓包扎止血法:用紗布、棉花等做成軟墊,放在傷口上再加包扎,來(lái)增強(qiáng) 壓力而達(dá)到止血。c 止血帶止血法:選擇彈性好的橡皮管、 橡皮帶或三角巾、 毛巾、 帶狀布條等, 上肢出血結(jié)扎在上臂上 1/2處 (靠近心臟位置 , 下肢出血結(jié)扎在大腿上 1/3處 (靠 近心臟位置 。結(jié)扎時(shí),在止血帶與皮膚之間墊上消
53、毒紗布棉紗。每隔 25 40分鐘 放松一次,每次放松 0.5 1分鐘。觸電事故應(yīng)急救援預(yù)案觸電急救辦法是動(dòng)作迅速, 救護(hù)得法, 切不可驚慌失措, 束手無(wú)策。 要貫徹 “迅 速、就地、正確、堅(jiān)持“的觸電急救八字方針。發(fā)現(xiàn)有人觸電,首先要盡快使觸電 者脫離電源,然后根據(jù)觸電者的具體癥狀進(jìn)行對(duì)癥施救,打“ 120”急救電話,詳 細(xì)報(bào)告事故發(fā)生地及觸電者人數(shù)情況。脫離電源的基本方法有:將出事附近電源開(kāi)關(guān)拉掉或電源插頭拔掉,以切斷電源。用干燥的絕緣木棒、竹竿、 布帶等物將電源線從觸電者身上拔離或者將觸電者 拔離電源。必要時(shí)可用絕緣工具(如帶有絕緣柄的電工鉗子、木柄斧頭以及鋤頭切斷電 源。救護(hù)人員可戴上手
54、套或在物上包纏的衣服、圍巾、帽子等絕緣物品拖拽電者,使之脫離電源。如果觸電者由于痙攣手指緊握導(dǎo)線纏繞在身上, 救護(hù)人員可先用干燥的要板塞 進(jìn)觸電者身下使其與地絕緣來(lái)隔斷入地電流,然后再采取其他辦法把電源切斷。 如果觸電者及斷落在地上的帶電高壓導(dǎo)線,且沿未確證線路無(wú)電之前,救護(hù)人 員不可進(jìn)入斷線落線地點(diǎn) 8米的范圍內(nèi),以防跨步電壓觸電。 進(jìn)入該范圍的救護(hù)人 員應(yīng)穿絕緣或臨時(shí)雙腳并攏跳躍地接近觸電者。觸電者脫離帶電導(dǎo)線后,應(yīng)迅速將 其帶到 8米以外立立即開(kāi)始觸電急救。 只在確證線路中無(wú)電。 才可在觸電者離開(kāi)觸 電導(dǎo)線后就地急救。在使觸電者脫離電源時(shí)應(yīng)注意的事項(xiàng):未采取絕緣措施前,救護(hù)人員不得直接觸
55、及觸電者的皮膚和潮濕的衣服。 嚴(yán)禁救護(hù)人員直接用物推、拉和觸摸觸電者,救護(hù)人員不得采用金屬或其他絕 緣性能差的物體(如潮濕木棒、布帶等作為救護(hù)工具。在拉拽觸電者離開(kāi)電源的過(guò)程中,救護(hù)人員宜用手操作,這對(duì)救護(hù)人員比較安 全。當(dāng)觸電者位于高處時(shí),應(yīng)采取措施預(yù)防觸電者脫離電源后墜地摔死。夜間發(fā)生觸電事故時(shí),應(yīng)考慮切斷電源后的臨時(shí)照明問(wèn)題,以利救護(hù)。 觸電者未失去知覺(jué)的救護(hù)措施:應(yīng)讓觸電者在比較干燥、通風(fēng)暖和的地方靜 臥休息,并派人嚴(yán)密觀察,同時(shí)請(qǐng)醫(yī)生前來(lái)或送醫(yī)院診治。觸電者已失去知覺(jué)但尚有心跳和呼吸的搶救措施:應(yīng)使其舒適地平臥著, 解 開(kāi)衣服以利呼吸,四周不要圍人,保持空氣流通,冷天應(yīng)注意保暖,同時(shí)
56、立即請(qǐng)醫(yī) 生前來(lái)或送醫(yī)院診治。若發(fā)現(xiàn)觸電者呼吸困難或心跳失常,應(yīng)立即施行人工呼吸及 胸外心臟擠壓。對(duì)“假死”者的急救措施:當(dāng)判定觸電者呼吸和心跳停止時(shí),應(yīng)立即按心腹 蘇法就地?fù)尵取?3火災(zāi)和爆炸事故應(yīng)急救援預(yù)案發(fā)生火災(zāi)和爆炸,首先是迅速撲滅火源和報(bào)警,及時(shí)疏散有關(guān)人員,對(duì)傷者進(jìn)行救治?;馂?zāi)發(fā)生初期,是滅火救災(zāi)的最佳時(shí)機(jī), 發(fā)生火災(zāi)部位的人員要及進(jìn)把握這一 時(shí)機(jī),盡塊把火撲滅。在撲救的同時(shí)撥打“ 119”電話報(bào)警和及時(shí)向上級(jí)有關(guān)部門及領(lǐng)導(dǎo)報(bào)告。 在現(xiàn)場(chǎng)的消防安全管理人員,應(yīng)立即指揮員工撤離火場(chǎng)附近的可燃物,避免火 災(zāi)區(qū)域擴(kuò)大。組織有關(guān)人員對(duì)事故區(qū)域進(jìn)行保護(hù)。及時(shí)指揮、引導(dǎo)員工按預(yù)定的線路、方法疏
57、散、撤離事故區(qū)域。發(fā)生員工傷亡,要馬上進(jìn)行施救,將傷員撤離危險(xiǎn)區(qū)域,同時(shí)撥打“ 120”電 話求救。4坍塌事故應(yīng)急救援預(yù)案當(dāng)發(fā)生坍塌事故后,立即致電“ 120”急救中心,詳細(xì)報(bào)告事故發(fā)生的地點(diǎn) 及受傷人數(shù)。搶救重點(diǎn)是現(xiàn)場(chǎng)的人員、財(cái)物、設(shè)備。盡快把壓在人身上面的土方、 構(gòu)件搬離,受傷者抬出來(lái)并立即搶救。在急救中改專業(yè)人員未到達(dá)之前,應(yīng)馬上組織搶救傷者,首先觀察傷者的受 傷情況、 部位、傷害性質(zhì), 如傷員發(fā)生休克,應(yīng)先處理休克。遇呼吸、心跳停止者, 應(yīng)立即進(jìn)行人工呼吸,胸外心臟擠壓。處理休克狀態(tài)的傷員要讓其安靜、保暖、平 臥、少動(dòng),并將下肢抬高約 20度左右,盡快送進(jìn)醫(yī)院搶救治療。發(fā)現(xiàn)脊椎受傷者,
58、創(chuàng)傷處用消毒的紗布或清潔布等覆蓋傷口,用繃帶或布條 包扎。搬運(yùn)時(shí),將傷者平臥放在帆布擔(dān)架上或硬板上,以免傷者的脊椎移位、斷裂 造成截癱, 或?qū)е滤劳?。搶救脊椎受傷者的搬運(yùn)過(guò)程中嚴(yán)禁只抬傷者的兩肓與兩腳 或單肓背運(yùn)。發(fā)生傷者手足骨折,不要盲目搬動(dòng)傷者。應(yīng)在骨折部位用夾板把傷者受傷部 位臨時(shí)固定,使斷端不再移動(dòng)或刺傷肌肉、神經(jīng)或血管。固定辦法:以固定骨折處 上下關(guān)節(jié)為原則,或就地取材,用木板、竹頭等,在無(wú)材料的情況下,上肢可固定 在身側(cè),下肢與腱側(cè)下肢縛在一起。遇有創(chuàng)傷性出血的傷員,應(yīng)迅速包扎止血,使傷員保持在頭低腳高的臥位, 并注意保暖。動(dòng)用最快的交通工具或其他措施,及時(shí)把傷者送往鄰近醫(yī)院搶救,
59、 運(yùn)送途中 盡量減少顛簸同時(shí)密切注意傷者的呼吸、脈搏、血壓及傷口情況。(6電話報(bào)救須知在就地?fù)尵鹊耐瑫r(shí),應(yīng)立即打 120電話,向醫(yī)療單位求救,并準(zhǔn)備好車輛隨 時(shí)運(yùn)送傷員到就近的集美醫(yī)院救治。撥打電話時(shí)要盡量說(shuō)清楚以下幾件事:a: 說(shuō)明傷情和已經(jīng)采取了哪些措施,好讓救護(hù)人員事先做好急救準(zhǔn)備;b: 講清楚傷者在什么地方、什么路口,附近有什么樣特征;c :說(shuō)明報(bào)救者單位、姓名和電話;d: 通完電話后,應(yīng)派人在現(xiàn)場(chǎng)外等候接應(yīng)救護(hù)車,同時(shí)把救護(hù)車進(jìn)工地的路 上障礙及時(shí)給予清除,以得救護(hù)車到達(dá)后,能及時(shí)進(jìn)行搶救。(7事故后處理工作配合有關(guān)部門查明事故原因及責(zé)任人。以書面形式向上級(jí)寫出報(bào)告,包括發(fā)生事故時(shí)間
60、、地點(diǎn)、受傷 (死亡 人員姓 名、性別、年齡、工種、傷害程度、受傷部位。制定有效的預(yù)防措施,防止此類事故再次發(fā)生。組織所有人員進(jìn)行事故教育。向所有人員宣讀事故結(jié)果,及對(duì)責(zé)任人的處理意見(jiàn)。六、勞動(dòng)力計(jì)劃待做(包括專職安全生產(chǎn)管理人員、特種作業(yè)人員等七、計(jì)算書1、驗(yàn)算的荷載組合及其計(jì)算荷載分析根據(jù)本橋現(xiàn)澆頂板的結(jié)構(gòu)特點(diǎn),在施工過(guò)程中將涉及以下荷載形式: q 1 頂板自重荷載,鋼筋混凝土自重 25.1KN/M2。 q 2頂板底模荷載,按均布荷載計(jì)算取 0.3KN/M2。 q 3施工活荷載,按均布荷載計(jì)算取 3.00KN/M2。 q 4 振搗混凝土產(chǎn)生的荷載,對(duì)底板取 2.0 KN/M2,對(duì)側(cè)板取 4
61、.0 KN/M2。 q 5 新澆混凝土對(duì)側(cè)模的壓力。 q 6 傾倒混凝土產(chǎn)生的水平荷載,取 2.0 KN/M2。 q 7 支架自重,取 3.38 KN/M2。荷載組合模板、支架設(shè)計(jì)計(jì)算荷載組合 荷載計(jì)算 . 頂板自重計(jì)算 q 1計(jì)算q 1=25.1×1.0=25.1kpa取 2的安全系數(shù) , q1=25.1×2=50.2 kpa新澆混凝土對(duì)側(cè)模的壓力 q 5計(jì)算因現(xiàn)澆箱涵采取水平以每層 30cm 高度澆注, 在豎向上以 V=0.9m/h澆注速度控 制 , 砼入模溫度 T=20度 C 控制,因此新澆混凝土對(duì)側(cè)模的壓力q5= Pm=K×r ×h q 5 新澆
62、混凝土對(duì)側(cè)模的壓力。K 為外加劑修正系數(shù),不取摻緩凝外加劑 K=1.0當(dāng) V/t=0.9/20=0.045>0.035 h=1.53+3.8V/t=1.70m q 5=KPah r K P m22. 4470. 1260. 1= q 6 傾倒混凝土產(chǎn)生的水平荷載,取 2.0kPa 。 2、鋼管支架立桿強(qiáng)度及穩(wěn)定性驗(yàn)算立桿穩(wěn)強(qiáng)度驗(yàn)算現(xiàn)澆箱涵頂板厚度為 1.0m 支架立桿范圍內(nèi),扣件式鋼管支架體系采用 50×50×90cm 的布置結(jié)構(gòu)。根據(jù)立桿的設(shè)計(jì)允許荷載,當(dāng)橫桿步距為 120cm 時(shí),立桿可承受的最大允許豎 直荷載為N =35kN (參見(jiàn)公路橋涵施工手冊(cè)中表 13-5
63、碗口式構(gòu)件設(shè)計(jì)荷載 。 本工程所用鋼管為 48×2.5mm ,橫桿步距為 90cm ,取N =30kN 。立桿實(shí)際承受的荷載為:N=1.2(N G1K +NG2K +0.9×1.4N QK (組合風(fēng)荷載時(shí) N G1K 支架結(jié)構(gòu)自重標(biāo)準(zhǔn)值產(chǎn)生的軸向力; N G2K 構(gòu)配件自重標(biāo)準(zhǔn)值產(chǎn)生的軸向力 N QK 施工荷載標(biāo)準(zhǔn)值;于是,有:N G1K =0.5×0.5×q 1=0.5×0.5×25.1=6.275KN N G2K =0.5×0.5×q 2=0.5×0.5×0.3=0.075KNN QK =0
64、.5×0.9×(q3+q4+q7=0.45×(3.0+2.0+3.38=3.77KN則:N=2(NG1K+NG2K +0.9×1.4NQK=2×(6.275+0.075 +0.9×1.4×3.77=17.45KN<N =30KN ,強(qiáng)度能滿足要求。經(jīng)以上立桿強(qiáng)度驗(yàn)算現(xiàn)澆箱涵頂板厚度為 1m 支架立桿范圍內(nèi)碗扣式鋼管支架 體系采用 50×50×90cm 的布置結(jié)構(gòu)強(qiáng)度滿足要求。立桿穩(wěn)定性驗(yàn)算根據(jù)扣件式鋼管腳手架安全技術(shù)規(guī)范 JGJ130-2011有關(guān)模板支架立桿的穩(wěn) 定性計(jì)算公式:N/A+MW/W f
65、N 鋼管所受的垂直荷載, N=2(安全系數(shù) *(N G1K +NG2K +0.9×1.4N QK (組合風(fēng) 荷載時(shí) ,同前計(jì)算所得;f 鋼材的抗壓強(qiáng)度設(shè)計(jì)值, f =205N/mm2A 支架立桿的截面積 A =357mm 2(取 48mm ×2.5mm 鋼管的截面積 軸心受壓桿件的穩(wěn)定系數(shù),根據(jù)長(zhǎng)細(xì)比 查表即可求得 。i 截面的回轉(zhuǎn)半徑,查建筑施工扣件式鋼管腳手架安全技術(shù)規(guī)范附錄 B 得 i =15.8。長(zhǎng)細(xì)比 =L/i。L=h+2ah 為立桿步距; a 為頂層水平桿至頂托撐的距離L=0.9+2*0.35=1.6m 。于是, =L/i=1.6/0.016=100,參照建筑施
66、工扣件式鋼管腳手架安全技術(shù) 規(guī)范查附錄 C 得 =0.489。M W 計(jì)算立桿段有風(fēng)荷載設(shè)計(jì)值產(chǎn)生的彎距;M W =0.9×1.4×W K ×L a ×h 2/10W K =uz ×u s ×w 0u z 風(fēng)壓高度變化系數(shù), 參考 建筑結(jié)構(gòu)荷載規(guī)范 GB50009-2001第 30頁(yè) (取 山間盆地、谷地 u z =0.8u s 風(fēng)荷載腳手架體型系數(shù), 查 建筑結(jié)構(gòu)荷載規(guī)范 GB50009-2001表 7.3.1第 37項(xiàng)得:u s =1.0w 0基本風(fēng)壓,查 建筑結(jié)構(gòu)荷載規(guī)范 附表 D. (貴州貴陽(yáng), n 取 50年w 0=0.3K
67、N/m2故:W K =uz ×us ×w 0=0.8×1.0×0.3=0.24KN/ m2L a 立桿縱距 0.5m ;h 立桿步距 0.9m故:M W =0.9×1.4×W K ×La ×h 2/10=0.9*1.4*0.5*0.92/10 = 0.051 KN/m2W 截面模量查表 建筑施工扣件式腳手架安全技術(shù)規(guī)范 附表 B 得: W=5.08×103mm 3則, N/A+MW /W=17.45×103/(357×0.357 +0.051×106/(5.08×1
68、03= 146.96N/mm2 f =205N/mm2故立桿穩(wěn)定性滿足要求3、 立桿頂托、底托驗(yàn)算及地基承載地驗(yàn)算。立桿頂托、底托驗(yàn)算: N Rd通過(guò)前面立桿承受荷載計(jì)算,每根立桿上荷載最大值為頂板厚度為 1.0m , (箱 涵橫向兩側(cè)倒角處最厚為 1.4米,但該處增加了兩排加固斜撐,故不做驗(yàn)算立桿 布距為 50×50×90布置的立桿,即:N=2(NG1K+NG2K +0.9×1.4NQK=2×(6.275+0.075 +0.9×1.4×3.77=17.45KN頂托及底托承載力(抗壓設(shè)計(jì)值,一般取 R d =40KN;得:17.45KN <40KN ,因此立桿底托符合要求。因?yàn)轫斖袑?shí)際受力小于底托實(shí)際受力而設(shè)計(jì)值相同,所以頂托也滿足要求。 地基已經(jīng)過(guò)處理,箱涵底板為 C40鋼筋混凝土,所以箱涵底板的承載力不做 驗(yàn)算。附頂托、底托及底板示意圖 4、 扣件式支架立桿頂托上順橋鋼管驗(yàn)算 示意圖如下 順 橋 方 向 斷 面橫 橋 方 向 斷 面順橋每根鋼管抗彎計(jì)算q =(q1+ q2+ q3+ q4 ×B =(50.2 +0.3+3+2×0.5/2=13. 875kN/m 支撐鋼管按照集中荷載作用下的連續(xù)梁計(jì)算。 集中荷載 P 取木方支撐傳遞力。2. 78K N2. 78
溫馨提示
- 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 2023年深孔鉆項(xiàng)目評(píng)估分析報(bào)告
- 2024屆貴州省畢節(jié)大方縣德育中學(xué)高三第九次模擬考試數(shù)學(xué)試題試卷
- 不續(xù)簽合同離職
- 標(biāo)本收送協(xié)議書范本
- 銀屑病病例分享
- 新疆維吾爾自治區(qū)喀什地區(qū)巴楚縣2024-2025學(xué)年九年級(jí)上學(xué)期10月期中考試化學(xué)試卷(含答案)
- 瀘縣五中2024年秋期高一期中考試化學(xué)試題
- 《植物染料染色床上用品》
- 犬貓根管治療教學(xué)
- 13 A波的描述 基礎(chǔ)版2025新課改-高中物理-選修第1冊(cè)(21講)
- 小學(xué)一年級(jí)開(kāi)學(xué)安全教育主題班會(huì)課件
- 深圳舞臺(tái)照明燈項(xiàng)目實(shí)施方案(參考范文)
- 收款確認(rèn)單(新)(共4頁(yè))
- 歷史劇——民族英雄林則徐
- 監(jiān)控系統(tǒng)試運(yùn)行與方案
- 《我是交通小博士》PPT課件.ppt
- 流式細(xì)胞術(shù)報(bào)告單解讀
- 礦山電工課程設(shè)計(jì)
- 2流動(dòng)人員人事檔案轉(zhuǎn)遞通知單存根
- 恒電位儀操作規(guī)程
- 全縣蔬菜產(chǎn)業(yè)發(fā)展情況的調(diào)研報(bào)告 (3)
評(píng)論
0/150
提交評(píng)論