版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進行舉報或認領(lǐng)
文檔簡介
Schlumberger
IntelligentCompletionsAgendaFlowControlProductTRFC-HNWRFC-HTRFC-HBOdinIntelliZoneCompactSystemDescriptionAnAnnularFlowControlValvecontrolsflowbetweentheannulusandthetubing(orvise-versa),bymeansofflowports.AnIn-LineFlowControlValvecontrolsfluidflowingalongatubingandthroughtheflowportsbymeansofaplugandshrouddesign
PathoffluidflowIn-LineTRFC-Hx-LxAnnularPathoffluidflowChokeTRFC-Hx-AxTerminology:Annular&In-LineValvesApplication:DualzoneICwherecannotfitannularvalvesinsidelowercasing/linerTerminologyN+1ControlLineOperationN+1ControlLineOperationThevalvehasthecapabilityofmaintainingindividualcontrolwhileusingacommon‘shared’controllinebetweenmorethanonevalve.CommonControlLineIndividualControlLines4TheLineUp:IntelligentCompletionProductsDescriptionProductionandinjectionWithsandcontrolMulti-choke&On-offApplicationsCommingledproductionZonalgas/watershutoffSelectiveenhancedinjectionAutogasliftFeaturesSingleandDuallineoperatedTubingretrievableupto175°C/10KWirelineRetrievableMulti-dropoptionsN,N+1,<NWRFC-HTRFC-HN-APTRFC-HN-LPTRFC-HMTRFC-HBNumberofLinesOdinIntelliZoneCompactTRFC-HNValveDescriptionHydraulicallyoperatedUsesnitrogenforindexerreturnoperationBasedonprovenCamco(SCSSV)hydraulictechnologyStandardversion(TRFC-H)forannular/tubingortubing/annularflowcontrolShroudedversion(TLFC-H)forin-lineflowcontrol3-?”TRFC-H3-?”TLFC-HTRFC-HNFeaturesIncrementalchokeadjustment11positionsincludingfullyopenandclosedCustomisablechokesizesSingle?”hydrauliccontrollineFieldprovennitrogenspringclosureHighflowrate,flowareaequivalenttotubingMetaltometalchokeseal3-?”TRFC-HN-AP3-?”TRFC-HN-LPBinaryFlowControlValve-TRFC-HBDescriptionTubingRetrievableBinaryFlowControlValveApplyinghydraulicdifferentialpressurebetweentwocontrollinesactuatesthevalveN+1sharedlineFeaturesandBenefitsTheprotectorsleevepreventssealsfromcrossingflowports,protectingthemfromdamageThevalveutilizesanexternalpressuresleevethatishighlyresistanttoproblemsassociatedwithscaleThedesignistolerantofextremeerosionconditionsOversizedportsprovidea40,000bpdflowrateOdinFlowControlValveADualControlLineValveBalancedpiston(nonitrogen)8positionsincluding6chokingorOn/OffComplimentsthe3-1/2and51/2”sizeportfolioAnnular,in-lineandmulti-droppedversionsavailable21kipsscalebreakingforceIntegralcontingencyshiftingprofile–qualifiedwith tractorandstrokertoolInternalcolletformaintainingchokepositionProtectorsleevepreventsdamagetothechokesealsOdinFlowControlValveFourFlowConfigurationsInlineLP/LIAnnularAP/AITubingspecificdesignsAnnularandIn-LineversionsApplicationspecificdesignsProducerandInjectorversionsOdinFlowControlValveKeyFeaturesSimple,reliable&ruggeddesignBalancedpistonJ-slotindexingmechanismN+1controllineconfigurationPositivepressurecapabilityChangeindividualchokeswithoutaffectingothervalves8positionchoke–6customizablechokingpositionsIntegralcontingencyshiftingprofile–testedwithtractorandstrokertoolOdinFlowControlValveKeyFeaturesNotimeconsumingin-situfieldcalibrationofhydrauliccircuitryNocomplexhydrauliccircuitryAdditionalleakspathsandfailuremodesInternalColletformaintainingchokepositionPossibletorunmultiplevalvesonlessthanN+1controllines2.1sqinpistonarea-highscalebreakingforcewithlowactuationpressurespossibleAnchorplateforhydraulicconnectionsOdinFlowControlValve31/2”NominalTubingValveOverviewSpecificationsMax.O.D.Ax(Lx) 5.850in(7.510in)Min.I.D2.812inMax.WorkingPressure6,500psi(80ksi),7,500(95ksi),Max.OperatingTemperature325°FMin.OperatingTemperature40°FMin.StorageTemperature-40°FMax.LiquidFlowRate40,000bbl/d,25,000bbl/dchokedOdinFlowControlValve51/2”NominalTubingValveOverviewSpecificationsMax.O.D.Ax(Lx) 8.250in(9.240in)Min.I.D4.437in(4.312in)Max.WorkingPressure7,500(95ksi)Max.OperatingTemperature325°FMin.OperatingTemperature40°FMin.StorageTemperature-40°FMax.LiquidFlowRate70,000bbl/d,40,000bbl/dChokedFeatureOdinTRFC-HBTRFC-HNOperationBalancedpistonBalancedpistonNitrogenChargedBaseNumberofControlLines(whereN=numberofvalves)N+1N+1NNumberofPositions8(6choking)2(open,close)11(9choking)MaxDifferentialOpeningPressure-Qualified4,000psi10,000psi1,500psiHydraulicChamberArea2.1sq.in.4.860sq.in.1.574sq.in.ContingencyIntegralShiftingProfileRequirePackoffSleeveorperforatingRequirePackoffSleeveorperforatingFlowControlValveKeyComparisonsIntelliZoneCompact*SystemIntelliZoneCompact*SystemFirstfullyintegratedintelligentflowcontrolsystemformulti-zonewells–pretestedatthemanufacturingfacilityascompleteassemblyIntegratedsystem:designandevaluationsoftwarepackerflowcontrolvalvemultidropmoduledualgaugesystempositionsensorsurfacecontrolsystemcommissioningandcontrolsoftwareIntelliZoneCompactSystem:BenefitsBenefits:AnICSolutionthatiseasiertoinstallandoperateDeliveredfrommanufacturingasasinglesystemfullyintegratedandtestedReducedtestingtimeatthewellsiteReducedinstallationtimeatthewellsiteMorezonesdeployableonfewerhydrauliccontrollinesAutomaticsurfacecontrolforeaseofuseIntelliZoneCompactSystem:Details7x3-1/2&5-1/2x2-7/8sizeavailableSystemqualifiedasonemodule:17–32ftlongAssembledandtestedasasysteminmanufacturing5,000psiworkingpressure,250degFmaxMaterial:13Cror4140optionsMaxsettingdepth8000ftTVD(withoptionalMultidropModule)Gauges:Tubingandannuluspressure/temperaturewithpositionsensorFlowcontrolvalves:on/offandvariable4posProductionPacker:Hydraulicset,cut-to-releaseorshearreleaseoptionflexibility(V3)IsolationPacker:Hydraulicset–straightpullretrieve(V5)PackerMountingSubDualPressureGaugeFlowControlValveProtectiveClamp
Multi-dropModuleFilterSubHandlingSubHandlingSubIntelliZoneCompactSystem:ZoneLayoutDualcontrollinevalve2-position(On/Off),4-position(Choking)13Crand4140Metallurgy4designsofchokingports(S,M,L,XL)Maxflowarea125%oftubing(FullOpen)Maximumflowingdifferentialof1,000psiColletholdingmechanismIntegratedPositionSensorIntegralcontingency–shiftingprofileIntelliZoneCompactSystem:FlowControlValveUpperHousingIndexerandHydraulicHousingChokeHousingLowerHousing3-1/2”4-PosFCV2-7/8”4-PosFCVMakeuplength101inMakeuplength98inFlowControlValve:4-PositionChokingTypeMakeuplength72in3-1/2”O(jiān)n/OffFCVMakeuplength75in2-7/8”O(jiān)n/OffFCVUpperHousingHydraulicHousingChokeHousingLowerHousingFlowControlValve:On/OffBinaryTypeIntelliZoneCompactSystem:PackerHydraulicSetProductionPackersCTR,SPR7in23-26#or26-29#,5-1/2in17or20#V3HydraulicSetIsolationPackers7in23-26#or26-29#V513Crand4140MaterialwithHNBRElements5,000psiWPfromaboveandbelow(CTR)inIsolated,UnpluggedandPluggedscenariosFieldprovenslipsandelementsystemControllinebypasscapability:5x?IDFC(7x3-1/2),4x?IDFC(5-1/2x2-7/8)NomandrelmovementduringsettingPreventsdebrisbuildupabovetheslips(7”)IntelliZoneCompactSystem:MonitoringDualpressuregaugeforannularandtubingpressure0-5800psicalibrated0.2%typaccuracy1psiresolutionDualTemperaturesensorbuiltintopressuregauges2DegCaccuracy1DegCresolutionPositionsensorforflowcontrolvalveAbsolutepositionsensorDataandtelemetryprocessingFullyweldedexceptfortransducersealingFSKtelemetrywith1secondupdaterateAbsolutepositionsensorforflowcontrolvalveAvailableforOn-Offor4-PositionchokingvalveFullyweldeddesignMechanicalplungerconceptPositionofplungerisdetectedbymeasuringmagneticfieldchanges(non-contact)PlungeroperatesinhydraulicfluidchamberMonitoring:PositionSensorIndexerPlungerPCBAMRsensorMagnetMonitoring:PositionSensorIntelliZoneCompactSystem:MultidropModuleAllowsmorezonestobecontrolledwithlesshydrauliclines3versionsofmodulesavailabledependingonconfigurations2-Pulse(switcheseverypressurepulse)4-Pulse(switchesevery2ndpressurepulse)8-Pulse(switchesevery4thpressurepulse)MaxControlLinePressure:10,000psiMinControlLinePressure:7,500psiMinResetPressure:4,000psiHydraulicFluidCompatibility:OilandwaterbasedMaxSettingDepth:Welldependent.8,000ftfortypicalfluidService
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負責。
- 6. 下載文件中如有侵權(quán)或不適當內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 上半年教師資格考試《中學綜合素質(zhì)》真題及答案
- 2024-2030年中國婚慶策劃市場競爭力分析發(fā)展策略研究報告
- 2024-2030年中國地板抹布融資商業(yè)計劃書
- 2024-2030年中國四連體無塵服商業(yè)計劃書
- 2024年版施工勞務(wù)非材料供應(yīng)承包合同版
- 2024年版零售商墊資協(xié)議樣式版B版
- 2024年三舊改造建設(shè)項目合作協(xié)議書范本-智慧城市配套3篇
- 2024年小學二年級數(shù)學(北京版)-萬以內(nèi)數(shù)的加減法(二)-1教案
- 洛陽職業(yè)技術(shù)學院《視頻編輯》2023-2024學年第一學期期末試卷
- 2025年德州貨運從業(yè)資格模擬考試題
- 解、續(xù)聘物業(yè)服務(wù)意見單 選聘物業(yè)服務(wù)企業(yè)選票
- 李孟潮個體心理咨詢的操作
- 人工智能課題研究報告PPT模板
- 支氣管鏡吸痰操作標準
- 概率期末考試試題答案《概率論與數(shù)理統(tǒng)計B》
- 大學校園交通規(guī)劃以南京林業(yè)大學為例
- 山東2023泰安銀行春季校園招聘25人上岸提分題庫3套【500題帶答案含詳解】
- GB/T 11446.9-2013電子級水中微粒的儀器測試方法
- GB 8537-2018食品安全國家標準飲用天然礦泉水
- GB 31247-2014電纜及光纜燃燒性能分級
- 百詞斬-定語從句課件-(;)
評論
0/150
提交評論