




版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進行舉報或認(rèn)領(lǐng)
文檔簡介
目前文文件修改密碼:8362839更多數(shù)據(jù)請訪問精品數(shù)據(jù)網(wǎng)(.....)實施標(biāo)準(zhǔn)及國家注冊證號:1、中國醫(yī)療器械注冊證號:京藥監(jiān)械(準(zhǔn))字第2260379號2、中國醫(yī)療器械生產(chǎn)企業(yè)許可證號:京藥監(jiān)械生產(chǎn)許0098號3、醫(yī)療器械注冊產(chǎn)品標(biāo)準(zhǔn)號:YZB/京0485-HY-D02●HY-D02●序號序號DD型“華醫(yī)“華醫(yī)”拼音縮寫目錄112699101113141515192124一、概述············································································二、儀器介紹·····································································三、儀器正面、后面及關(guān)鍵配件示意圖·····························四、技術(shù)參數(shù)·····································································五、內(nèi)存程序處方表··························································六、基礎(chǔ)操作步驟圖··························································七、操作方法詳解······························································八、自動安全保護系統(tǒng)(詳解)············································九、注意事項·····································································十、禁忌癥·········································································十一、各類疾病臨床癥狀介紹············································十二、吸水電極板放置穴位圖············································十三、人體穴位參考圖·······················································十四、故障和維修·······························································實施標(biāo)準(zhǔn)及注冊證號·····················································見封面儀器裝箱單、保修卡·····················································見封底請認(rèn)真閱讀本說明書后再操作儀器)一、概述:人體患了疾病,需要用打針、吃藥等方法去診療。常言道“是藥三分毒”,雖有夸張,卻也一針見血地指出了“藥品毒副作用對人體危害之大”是個不容忽略客觀事實。認(rèn)真分析,究其根本,不難發(fā)覺藥品對人體毒副作用首先是由藥品成份本身結(jié)構(gòu)決定,其次來自我們給藥方法,即人為造成。比如:利用口服給藥,首先經(jīng)過口腔胃腸壁吸收全身血液循環(huán)最終抵達患部。在這一藥品漫長旅行路途中,經(jīng)歷了那么多不相干健康臟器,造成了一路“污染”和“浪費”,這種絕正確平均分配使真正需要對癥藥品患部得到卻是微乎其微,真有點“少、慢、差、費”味道!尤其是對于長久困擾眾多患者頸椎病、關(guān)節(jié)炎、骨質(zhì)增生等骨關(guān)節(jié)病類疾病,其病因、病況雖各不相同,但正?;顒臃秶芟?、肢體麻木、腫脹,疼痛難忍,是這類疾病共有臨床癥狀。中醫(yī)理論講“痛則不通,通則不痛”,而骨關(guān)節(jié)病引發(fā)疼痛、腫脹正是這一機理具體表現(xiàn)。它說明了血液循環(huán)是否通暢和疼痛是辯證因果關(guān)系。所以單純地用激素類止疼藥品舍本治標(biāo)方法肯定是不可取。但那種較為普遍宣傳用所謂良藥或祖?zhèn)髅胤降人幤啡ァ盎觥?,其診療效果往往又不甚理想,這到底是為何呢?經(jīng)廣泛臨床實踐、辯證分析,其根本原因是:既然患部(比如膝關(guān)節(jié)骨質(zhì)增生)已被確診為“血瘀”(即患部及周圍范圍血液循環(huán)不通暢),那么用口服良藥又怎樣在患部血液循環(huán)不通暢(血瘀所致)前提下經(jīng)過血液循環(huán)路徑將藥品直接送達患部去發(fā)揮治瘀功效呢?所以診療效果不甚理想是肯定結(jié)果。其實,骨關(guān)節(jié)病類患者患部實乃最需營養(yǎng)之處,也正是血液循環(huán)不通暢之處。能夠說正是“血瘀”造成有效藥品不能立即送至病灶,或說患部藥品濃度較低是致使藥力作用不能充足發(fā)揮其效力關(guān)鍵??偠灾翰浑y看出,診療骨關(guān)節(jié)類疾病,首先應(yīng)為患部發(fā)明一個良好授藥環(huán)境,使之通暢。并應(yīng)和此同時,將足夠濃度、劑量對癥藥品應(yīng)用靶向給藥導(dǎo)入法直接將藥品送至患部,使病灶區(qū)在多方綜合診療(即物理診療、藥品診療、電流按摩、反射診療法等)攻擊之下,促進其炎癥消失、吸收水腫、減輕壓力,致痛物質(zhì)移除,從而消除致病原因,結(jié)束患部惡性循環(huán)狀態(tài),使患者疼痛癥狀顯著減輕、活動受限范圍縮小,在此基礎(chǔ)上,發(fā)揮患者本身運動能力,調(diào)整身體免疫功效等方面主動原因,群起而攻之,進而使患部進入良性循環(huán)狀態(tài),真正取得事半功倍、立竿見影診療效果。二、HY-D02A型計算機中頻藥品導(dǎo)入診療儀(智慧移動單路)介紹1、療效好是02A智能移動單路儀器特色之一:療效好=動態(tài)診療+靜態(tài)診療+三塊溫?zé)嵋苿游姌O板本儀器含有了動態(tài)診療和靜態(tài)診療相結(jié)合獨特優(yōu)點。所謂動態(tài)診療就是在診療過程中三塊溫?zé)嵛姌O板可左右隨意移動,而且移動速度快慢可調(diào);所謂靜態(tài)診療就是一旦找到了致痛點或舒適點便可將診療點鎖定,進行針對性定點診療,這種獨特設(shè)計既可對病灶區(qū)進行局部診療,也可對病灶周圍區(qū)域進行動態(tài)診療,真正做到捕捉病灶、靶向?qū)?、靶向按摩,逐點逐面地消除炎癥,活血化瘀,疏通經(jīng)絡(luò),提升療效?;颊咴谑褂弥蓄l類儀器診療時,常常埋怨地說:“這兩塊電極板怎么一塊勁頭大,另一塊一點勁全部沒有呀!”。更有患者會直截了當(dāng)?shù)卣f:“您這儀器怎么就只能診療一個點???我左肩、右肩及中間大椎一趟線全部疼,您能不能想措施給處理呢?”現(xiàn)在廣大患者使用中頻類儀器輸出是由兩塊電極板組成一組電路輸出,從設(shè)計上講,這兩塊電極其中一塊是主作用極(勁頭大),而另一塊是輔助極(勁頭?。?,這么就只能照料一邊病灶區(qū)(穴位點),顧此失彼。所以不管怎樣不厭其煩地耐心地調(diào)整調(diào)換,其結(jié)果全部會無功而返。經(jīng)調(diào)查,眾多醫(yī)生和患者全部迫切地期望中頻類儀器廠家能設(shè)計生產(chǎn)出那種真正能滿足患者診療需要,安全可靠,診療效果好且使用方便好儀器來。具體地說:期望這種新儀器設(shè)置含有多個診療點(不要只一個,最少2~3個)且每個診療點全部能夠按診療要求進行單點診療或多點診療。假如再要求高一點,在診療要實現(xiàn)以上這些功效最關(guān)鍵一點,比如:自動尋點、吸水電極極板左右自由程序化移動等,均不需要患者手里拿著吸水電極板在患部一點一點地去尋求,去移動,而只是需要操作者輕按一下儀器上功效鍵便可全部自動完成,這么設(shè)計使逐點、逐線、逐面三維立體診療變成了現(xiàn)實,從而使疏通經(jīng)絡(luò)(經(jīng)絡(luò)通暢)、活血化瘀(瘀滯疏散)有放矢你使用了HY-D02A型計算機中頻藥品導(dǎo)入診療儀(智慧移動單路)就會真正體會到。2、確保安全是02A智能移動單路儀器特色之二:應(yīng)用這類診療儀診療疾病,確?;颊呤褂冒踩痛_有療效,是醫(yī)生和患者首先關(guān)心,也是生產(chǎn)廠商必需做到。現(xiàn)在社會上流通本類診療儀,品種繁多,但均未設(shè)置輸出斷路自動安全保護系統(tǒng)。致使電擊患者現(xiàn)象常常發(fā)生。比如:在診療時,讓患者適應(yīng)診療劑量必需是一點一點緩慢增加上去,而不是忽然跳到所需值。不過,在診療過程中正是因為患者挪動一下診療體位就有可能造成接處不良或診療線斷線、電極板脫落等等,這全部能使輸出斷路即患者感覺不到診療動作。一旦忽然接上,會在瞬間劑量由零突增到最大,這突如其來大劑量,輕者使患者嚇一跳(電擊所致),重者會造成醫(yī)療事故。針對這種不安全現(xiàn)實狀況,為了確?;颊呤褂媒^對安全。本儀器為此設(shè)置了獨一無二自動安全保護系統(tǒng)。其設(shè)計原理是:應(yīng)用計算機每時每刻地自動監(jiān)測輸出回路電流,一旦輸出回路電流為零(輸出斷路),計算機會立即中止輸出。待故障消除后儀器會自動緩慢恢復(fù)輸出到設(shè)定安全劑量,然后依據(jù)病況需要再手動一點一點地增加到所需值。這么設(shè)計就有效地預(yù)防了輸出劑量在瞬間內(nèi)由最小突增到最大值,以致電擊患者現(xiàn)象發(fā)生,從而確?;颊呤褂脙x器絕對安全。3、儀器機理在電場力作用下,把藥品電解成離子狀態(tài),利用同性相斥,異性相吸特征,將藥品離子引入人體內(nèi)給藥方法叫做藥品離子導(dǎo)入法。這種方法自20世紀(jì)六十年代傳入中國,因為受當(dāng)初科技還不發(fā)達條件所限制,無法克服在藥品導(dǎo)入過程中出現(xiàn)極化電場,致使藥品導(dǎo)入極難進行。多年來,仍有些廠家采取這種過時、極不完善設(shè)備在給患者診療,但當(dāng)中不乏有些廠家千方百計對此有所改善,但還存有很多缺點和弊端。就說現(xiàn)在市場上流通直流藥品導(dǎo)入診療儀、低頻診療儀、中頻診療儀等各類儀器全部有各自獨特診療功效,不過受其本身條件局限,又全部各自存在著很多缺點和弊端。簡單地概括:中頻雙向電流含有顯著降低人體阻抗并可進入人體較深病變部位,不易發(fā)生電解,還含有提升生物膜通透性、鎮(zhèn)痛止疼及消炎作用。但不含有藥品離子導(dǎo)入功效;低頻電流含有顯著興奮刺激神經(jīng)組織引發(fā)肌肉強烈收縮作用,還能夠刺激內(nèi)臟平滑肌并調(diào)整其張力,恢復(fù)內(nèi)臟正常功效。但低頻電流作用于人體時有疼痛感,人體不易接收,且不能進行藥品離子導(dǎo)入;直流電流含有顯著擴張血管、促進血液循環(huán)及有條件進行藥品離子導(dǎo)入功效。但其易產(chǎn)生電解、作用于人體深度較淺等不足之處。真是尺有所短,寸有所長??!鑒于上述各物理頻段電流客觀存在診療作用和弊端,所以說試圖利用某單一頻段就能治愈臨床上復(fù)雜疾病是不現(xiàn)實。北京華醫(yī)新技術(shù)研究所本著“臨床實踐是檢驗醫(yī)療儀器功效之唯一標(biāo)準(zhǔn)”標(biāo)準(zhǔn),利用現(xiàn)代計算機技術(shù),將中頻儀、低頻儀及藥品導(dǎo)入儀三類儀器功效之精華巧妙地濃縮于一身,研制成功了新一代HY-D02A型計算機中頻藥品導(dǎo)入診療儀(智慧移動單路)。該儀器是把中國外醫(yī)療教授多年臨床實踐經(jīng)驗及一生心得提煉、組合成多種物理診療程序(即處方),使一系列不一樣診療參數(shù)及物理波形在微電腦控制下組合輸出?;颊咧恍鑼ΠY選擇對應(yīng)診療處方,患者便可取得教授等級診療。在診療過程中,患部同時接收了中頻、低頻、直流等儀器及對癥藥品綜合診療功效。且上述多種功效不是簡單迭加關(guān)系,而是相互協(xié)同、相互促進,起到推波助瀾作用,患者可享受到針灸和人工手法按摩所不及多種揉捏、推拿、敲擊、按壓、拍打、震顫等無法言表電流按摩動作。最大程度地發(fā)揮其獨特綜合診療功效。本儀器綜上述多種功效之大成集中作用于病灶,其功效是引發(fā)機體所需要回復(fù)性反應(yīng),消除病因及病理過程,恢復(fù)被破壞了生理平衡,喚起和增強機體防御系統(tǒng),并發(fā)明良好授藥環(huán)境,從而借助藥品藥理功效而達成治病和防病目標(biāo)。經(jīng)臨床實踐證實:本儀器診療效果顯著、見效快,尤其是消炎、止疼可謂立竿見影。含有應(yīng)用范圍廣、操作簡單方便、安全可靠、無針、無痛、無毒副作用,經(jīng)濟實用。深受醫(yī)院及廣大患者好評,值得更深入推廣使用。三、儀器正面、后面及關(guān)鍵配件示意圖儀器正面示意圖HY-D02A型計算機中頻藥品導(dǎo)入診療儀(智慧移動單路)一、頸椎病1、HY-D02A型計算機中頻藥品導(dǎo)入診療儀(智慧移動單路)一、頸椎病1、頸椎骨質(zhì)增生2、頸椎椎間盤突出3、頸部僵硬手指麻木4、韌帶粘連、腫痛腰椎間盤突出11、膝關(guān)節(jié)骨性關(guān)節(jié)炎12、13、關(guān)節(jié)腔積液、腫脹14、15、16、軟組織損傷5、6、腰椎骨質(zhì)增生7、腰疼、腰肌勞損8、腰椎椎管狹窄9、10、坐骨神經(jīng)痛處方表1三、二、膝關(guān)節(jié)骨1三、二、膝關(guān)節(jié)骨性關(guān)節(jié)炎62435華醫(yī)診療儀62435華醫(yī)診療儀MK北京華醫(yī)新技術(shù)研究所MK北京華醫(yī)新技術(shù)研究所1415QSSN1415QSSN開/關(guān)切換降低增加選擇開/關(guān)切換降低增加選擇97812131110978121311109.處方、時間、劑量降低鍵9.處方、時間、劑量降低鍵10.“手動”、“自動”切換鍵11.開/關(guān)鍵向A1方向移動鍵A1、A0、A2三點之間運動速度加緊鍵向A2方向移動鍵A1、A0、A2三點之間運動速度減緩鍵14.“手動”指示燈15.“自動”指示燈注釋說明:1.診療處方表2.液晶顯示器3.“中頻”方法指示燈4.“導(dǎo)入”方法指示燈5.“診療”狀態(tài)指示燈6.“保護”狀態(tài)指示燈7.處方、時間選擇鍵8.處方、時間、劑量增加鍵1212、1313、儀器后面示意圖A1A1A0A2遙控1A開關(guān)加熱導(dǎo)入1234567注釋說明:1.診療線黑色六芯插頭插孔2.診療線紅色六芯插頭插孔3.診療線白色六芯插頭插孔4.遙控器灰色五芯插頭插孔5.加熱/常溫功效開關(guān)6.導(dǎo)入/中頻功效開關(guān)7.1A保險座8.電源開關(guān)中頻常溫中頻常溫關(guān)鍵配件示意圖A2A0AA2A0A1A1A0A2遙控器增加降低吸水電極板吸水電極板897654321診療線三端診療線897654321診療線三端診療線注釋說明:1.診療線黑色六芯插頭注釋說明:1.診療線黑色六芯插頭2.診療線紅色六芯插頭3.診療線白色六芯插頭4.診療線黑色三端插頭5.診療線紅色三端插頭5.診療線紅色三端插頭6.診療線白色三端插頭7.檢機負(fù)載黑色六芯插頭10.遙控器灰色五芯插頭11.遙控器操作面板檢機負(fù)載遙控器四、技術(shù)參數(shù):1、電源電壓:220V50HZ功率:15W2、內(nèi)存處方:16個調(diào)幅度:100%3、輸出方法:①計算機中頻(雙向)②藥品導(dǎo)入(單向)③加熱(溫?zé)彷敵觯艹兀ú患訜幔菔謩臃椒á拮詣臃椒?、輸出波形:矩形波、三角波、指數(shù)波、棱形波、階梯波、正弦波、鋸齒波、積分波、微分波等。5、儀器外型尺寸:300×245×70mm凈重:Kg6、外包裝尺寸:350×290×110mm毛重:Kg五、內(nèi)存程序處方表:123456789101112131415、風(fēng)濕、類風(fēng)濕性關(guān)節(jié)炎16、軟組織損傷液晶顯示處方北京華醫(yī)新技術(shù)研究所0120:液晶顯示處方北京華醫(yī)新技術(shù)研究所0120:00調(diào)整三塊電極板作用人體作用點A0、A1、A2之間相互轉(zhuǎn)換速度,即減緩三點之間運動速度。?鍵?K鍵鎖定A0-A2和A0-A1兩點之間診療,真正達成病痛部位對癥診療效果。1.打開電源開關(guān)1.打開電源開關(guān)撥動后背板上中頻撥動后背板上中頻/導(dǎo)入開關(guān),向下至“中頻”方法,“中頻”綠色燈點亮,向上至“導(dǎo)入”方法,“導(dǎo)入”綠色燈點亮。2.按動按動N鍵診療處方“01”閃動,等候選擇,本機設(shè)置16個診療處方。3.按動△按動△鍵或▽鍵選擇“01處方~16處方”之間對應(yīng)診療處方。4.再次按動N再次按動N鍵診療時間“20”閃動,等候調(diào)整?!?0”為機內(nèi)預(yù)置優(yōu)選時間。5.調(diào)整改療時間。本機設(shè)置診療時間范圍為1~40min。6.處方和時間選擇完成,將輸出診療線三色六芯插頭分別插入儀器后背輸出插孔上,即黑色插頭插入處方和時間選擇完成,將輸出診療線三色六芯插頭分別插入儀器后背輸出插孔上,即黑色插頭插入A1插孔,紅色插頭插入A0插孔,白色插頭插入A2插孔。(注意插頭上分別印有“”字樣,插入時面向儀器后背板,將此箭頭對準(zhǔn)插孔插槽并插入,且插實插牢。同時將診療線另外三色三端金屬插頭分別插入吸水電極板對應(yīng)插孔內(nèi)。若選擇“中頻”方法,將吸水電極板吸水面用溫水浸濕浸透,擠去多出水分,再用綁帶將其固定在診療部位;若選擇“導(dǎo)入”方法,將吸水電極板吸水面用溫用浸濕浸透,擠去多出水分,并在吸水電極板吸水面上或診療部位皮膚上涂上將被導(dǎo)入藥液,吸水面緊貼在需要診療部位,再用綁帶將其固定。注意:做導(dǎo)入診療時,切勿將吸水電極板吸水面摘下。7.7.撥動后背板上常溫/加熱開關(guān),向下至撥動后背板上常溫/加熱開關(guān),向下至“常溫”狀態(tài),即吸水電極板無熱輸出,向上至“加熱”狀態(tài),即吸水電極板有熱輸出。狀態(tài),即有8.“診療“診療”綠色燈點亮,同時“手動”綠色燈點亮,對應(yīng)診療處方改為劑量“00”并閃動,等候調(diào)整。9.10.11.11.12.12.13.14.14.調(diào)整三塊吸水電極板作用人體作用點A0、A1、A2之間相互轉(zhuǎn)換速度,即加緊三點之間運動速度。調(diào)整三塊吸水電極板作用人體作用點A0、調(diào)整三塊吸水電極板作用人體作用點A0、A1、A2之間相互轉(zhuǎn)換速度,即減緩三點之間運動速度。15.16.七、操作方法詳述:2、處方選擇:按動選擇(N)鍵,處方“01”閃動,表示診療處方等候調(diào)整。此時按動增加()鍵或降低()鍵,可在01處方~16處方之間任意選擇。3、時間選擇:再次按動選擇(N)鍵,處方閃動停止。時間“20”開始閃動,表示診療時間等候調(diào)整。此時按動增加()鍵或降低()鍵,調(diào)整改療時間,本機設(shè)置診療時間范圍為:1~40分鐘。4、5、67、上述準(zhǔn)備工作檢驗無誤后,按動開/關(guān)(S)鍵,診療綠色指示燈點亮,“手動”綠色指示燈點亮,處方停止顯示,劑量“00”閃動,秒點開始倒計時,表示此次診療開始,按動增加()鍵,劑量“00”停止閃動,劑量數(shù)值(表示作用力大?。┮来卧黾?,患者可依據(jù)病況需要按動增加()鍵或降低()鍵,直至所需劑量。本儀器設(shè)置劑量范圍00~85。8、本機在“手動”診療中設(shè)計了定點轉(zhuǎn)移功效,按動開/關(guān)(S)鍵后,A0號極板(紅色插頭)和A1號極板(黑色插頭)形成診療回路,若您需要轉(zhuǎn)移診療點,則按動?K(A2/快)鍵,診療點會由A0-A1向A0-A2方向進行轉(zhuǎn)移,在轉(zhuǎn)移過程中“手動”綠色燈處于閃動狀態(tài),當(dāng)閃動停止,表示作用點根本轉(zhuǎn)移。若您需要再次轉(zhuǎn)移診療點,則按動M?(A1/慢)鍵,則由A0-A2向A0-A1方向進行轉(zhuǎn)移。9、按動切換(Q)鍵,“手動”診療方法立即轉(zhuǎn)為“自動”診療方法,“手動”綠色燈滅,“自動”黃色燈點亮,三塊吸水電極板作用人體作用點A1、A0、A2之間自動程序移動,由點到面形成立體圍繞診療。若您需要加緊三點之間運動速度,按動?K(A2/快)鍵,“自動”黃色燈處于閃動狀態(tài),當(dāng)閃動停止,表示三點之間運動速度加緊至極點;若您需要減緩三點之間運動速度,按動M?(A1/慢)鍵,“自動”黃色燈處于閃動狀態(tài),當(dāng)閃動停止,表示三點之間運動速度減緩至極點。在三塊吸水電極板作用人體作用點自動程序移動過程中,若您需要鎖定兩點之間定點診療,則再次按動切換(Q)鍵,“自動”黃色燈滅,“手動”綠色燈點亮,“自動”程序移動轉(zhuǎn)為“手動”定點診療,此時患者能夠真正體會到病痛部位對癥診療效果。10、在診療過程中,處方立即間均不得修改,其增加()鍵和降低()鍵只起劑量加減修改作用,切換(Q)鍵切換“手動”和“自動”功效。12、診療完成,儀器自動報警停機,顯示系統(tǒng)恢復(fù)診療前狀態(tài)?;颊咚砷_綁帶,取下電極板后關(guān)閉電源開關(guān)并拔掉插頭即可。八、自動安全保護系統(tǒng):(詳解)九、注意事項:1、開啟電源開關(guān)后再在診療部位上放吸水電極板,取下吸水電極板后再關(guān)電源開關(guān)。2、使用導(dǎo)入方法診療時,切勿將吸水電極板吸水面摘下。6、吸水電極板放置位置通常在病變部位穴位點、阿是穴(疼痛點)、肌肉兩端(尤其是小腿肌肉)或遵醫(yī)囑放置。8、液晶顯示混亂,關(guān)機后重新開啟即可消除。9、診療輸出劑量大小以適中為好,不要一味追求過大。10、高頻儀器(如:微波、超短波)對本儀器含有干擾影響。不要和本儀器放在同一房間內(nèi)使用。11、夏季使用本儀器通常連續(xù)工作時間不超出4小時。不診療時關(guān)掉電源開關(guān),拔掉電源插頭。十、禁忌癥出血傾向、活動性肺結(jié)核、破傷風(fēng)、腫瘤、妊娠、精神病及心力衰竭、裝有心臟起博器及不適應(yīng)電刺激診療患者均嚴(yán)禁使用本儀器診療。心臟及心臟投影區(qū),太陽穴及孕婦下腹部均不得作為診療部位。十一、各類疾病臨床癥狀介紹:1、頸椎病頸椎病又稱頸椎綜合癥,是中老年人常見多發(fā)病,亦為臨床疑難病。其發(fā)病原因是在頸椎間盤退行改變(即:骨質(zhì)增生)基礎(chǔ)上,受應(yīng)力(包含急性損傷、慢性勞損壓力和張力)作用,發(fā)生椎體及其附件骨質(zhì)增生和肌肉、肌腱、韌帶、關(guān)節(jié)囊等軟組織病理改變,引發(fā)頸神經(jīng)根、頸段脊髓、椎動脈、頸交感神經(jīng)等受刺激和壓迫,以至發(fā)生損傷及繼發(fā)性改變,出現(xiàn)一系列復(fù)雜臨床癥狀。頸椎病病理過程是因頸椎間盤退行性改變(骨質(zhì)增生),而致后關(guān)節(jié)囊及鉤椎關(guān)節(jié)松弛,其通透性逐步降低,造成髓核逐步脫水,以致纖維化,椎間盤厚度減小、變窄,關(guān)節(jié)腔減小,造成水腫、無菌性炎變。其臨床表現(xiàn)差異較大,常見有頭、頸、肩、背及上肢頑固性定位疼痛和麻木,睡眠、低頭勞動或頸部活動時癥狀加重;絕大部分患者椎旁有壓痛并可摸到硬結(jié);頭頸上肢活動受限;咽喉有異物感、胸膈悶痛等癥狀。有部分患者以連續(xù)性頸臂痛呈陣發(fā)性加劇為主。患側(cè)上肢可出現(xiàn)顯著根性癥狀,如手指疼痛、麻木、無力、肌肉萎縮等癥狀。當(dāng)咳嗽、深呼吸時,均可誘發(fā)患肢癥狀陣發(fā)性加劇。應(yīng)用本儀器處方“一”診療可減輕神經(jīng)根刺激和壓迫,消除神經(jīng)根炎性水腫,改善脊髓血供營養(yǎng)。延緩或減輕椎體及關(guān)節(jié)囊、韌帶鈣化、骨化過程,減輕根部粘連,加強對癥鎮(zhèn)痛止疼、消除關(guān)節(jié)炎癥、軟化斑痕、松懈粘連,使患者疼痛、麻木等癥狀減輕。診療方法:可選擇中頻或?qū)敕ㄖ行┝吭\療。藥品可選擇奴佛卡因、碘化鉀、陳醋、冰醋酸、威靈仙、草烏等。每日一次,每次20分鐘,一療程為20次。2、腰椎間盤突出人腰椎有五節(jié),節(jié)和節(jié)之間全部有個類似軟墊樣圓盤狀結(jié)構(gòu)稱為椎間盤。椎間盤基礎(chǔ)無血液供給,腰椎間盤通常在20歲就開始發(fā)生退行性改變,椎間盤退變及腰部勞損,可造成椎體骨質(zhì)增生改變,甚至形成骨刺,發(fā)生椎體不穩(wěn)。伴隨年紀(jì)增加,當(dāng)增生骨刺妨礙了關(guān)節(jié)功效或刺激周圍軟組織時,則產(chǎn)生局部疼痛、麻木、發(fā)涼、運動不靈活或僵硬感,而疼痛有時可呈放射性。腰椎增生時,腰痛顯著。腰椎間盤突出癥發(fā)生原因是在椎間盤退行性改變基礎(chǔ)上伴有外傷,周圍韌帶松弛是椎間盤突出內(nèi)因。而外傷、勞損引發(fā)纖維環(huán)破裂,髓核突出,壓迫脊髓神經(jīng)根,產(chǎn)生充血、水腫、粘連等形成無菌性炎癥,從而引發(fā)腰腿痛。其臨床關(guān)鍵表現(xiàn)多為一側(cè)腰痛,一側(cè)腿后外側(cè)串痛或麻木感(沿坐骨神經(jīng)行徑)。而中央型則為雙下肢麻痛,咳嗽、噴嚏、大便用力時腿痛加重。腰椎有輕重不一樣側(cè)彎,下腰部正常生理凹陷消失,患側(cè)下腰部棘突旁1~2厘米處有壓痛,并向患肢放射,直腿抬高試驗陽性。應(yīng)用本儀器處方“二”診療,可顯著促進局部血液循環(huán)、疏通瘀滯、打通痹阻血脈,可開啟退變細胞,使其恢復(fù)正常功效,可改善纖維環(huán)周圍血液循環(huán),緩解肌肉痙攣和疼痛,消除炎癥、吸收水腫,降低增生骨質(zhì)周圍軟組織慢性滲出。消除因腰間盤突出、骨質(zhì)增生引發(fā)根性坐骨神經(jīng)痛。增強腰部肌肉、韌帶支持能力,減輕疼痛。促進突出椎間盤組織還納及突出髓核復(fù)位,促進椎間盤纖維環(huán)破裂處形成“纖維包裹”加強對“損傷微弱處”固定,從而發(fā)揮診療作用。輔以中、西藥內(nèi)服,使藥效殊途同歸,其效更佳。診療方法:使用“中頻”方法,診療點采取痛點或神經(jīng)干部位,兩吸水電極板可并置于腰部疼痛部位。(腰椎間盤突出者診療劑量偏小為佳,腰肌勞損及腰疼等患者診療劑量適中。)若選擇“導(dǎo)入”方法,藥品可用碘化鉀(負(fù)極)或陳醋(負(fù)極)。如有神經(jīng)根粘連者,可選擇碘化鉀(負(fù)極)或在腰部用10%硫酸鎂(正極)進行“導(dǎo)入”診療。每日1~2次,每次20分鐘,20次為一療程。3、膝關(guān)節(jié)骨性關(guān)節(jié)炎膝關(guān)節(jié)是骨性關(guān)節(jié)炎好發(fā)部位。和髖關(guān)節(jié)等其它部位骨關(guān)節(jié)炎一樣,膝關(guān)節(jié)骨關(guān)節(jié)炎也分原發(fā)性和繼發(fā)性兩種。原發(fā)性骨關(guān)節(jié)炎也就是老年性骨關(guān)節(jié)炎,多見于老年,尤其是老年婦女。繼發(fā)性骨關(guān)節(jié)炎則往往是因為全身性疾病和膝關(guān)節(jié)急性創(chuàng)傷、慢性勞損所致。慢性勞損原因中以肥胖較為常見。肥胖者因軀體重量較大,使膝關(guān)節(jié)應(yīng)力超荷,加速了膝關(guān)節(jié)軟骨磨損破壞,從而造成膝關(guān)節(jié)骨關(guān)節(jié)炎。膝關(guān)節(jié)骨關(guān)節(jié)炎病理改變關(guān)鍵表現(xiàn)在軟骨軟化,彈性消失,軟骨基質(zhì)喪失硫酸軟骨素,膠原纖維暴露,軟骨面變得粗糙、碎裂,軟骨下新骨形成。在骨端邊緣,尤其是在不負(fù)重區(qū)有骨贅形成,滑液也可被擠入骨內(nèi)形成囊腫。滑膜攝取變性軟骨碎片造成絨毛肥大,關(guān)節(jié)囊纖維化并攣縮,在早期和急性炎癥期可相關(guān)節(jié)腔積液。因為膝關(guān)節(jié)骨關(guān)節(jié)炎上述病理改變,尤其是關(guān)節(jié)磨損,滑膜炎癥及關(guān)節(jié)周圍韌帶變性,炎癥等病理改變造成臨床上出現(xiàn)疼痛,關(guān)節(jié)僵硬,腫脹,活動受限,肌肉萎縮和關(guān)節(jié)畸形等一系列癥狀和體征。比如:疼痛癥狀往往是炎性改變,關(guān)節(jié)囊攣縮,骨充血等改變所致;腫脹則是滑膜炎癥滲液反應(yīng);僵硬和活動受限和關(guān)節(jié)囊纖維化骨贅,關(guān)節(jié)面碎片或游離體嵌入相關(guān)。常因老年組織變性及長久勞損引發(fā)骨質(zhì)增生;暴力或強大肌肉忽然收縮引發(fā)骨折;關(guān)節(jié)滑膜受化膿性細菌感染引發(fā)化膿性關(guān)節(jié)炎;外傷、風(fēng)濕、痛風(fēng)、感染引發(fā)滑囊炎;因跖腱膜及足短肌在其附著處產(chǎn)生新骨引發(fā)跟刺等。膝關(guān)節(jié)骨關(guān)節(jié)炎診療除了疼痛癥狀十分嚴(yán)重,非手術(shù)診療無效,關(guān)節(jié)畸形影響功效,關(guān)節(jié)內(nèi)游離體有交鎖等需要手術(shù)診療外,通常以非手術(shù)診療為主。應(yīng)用本儀器處方“三”中頻法診療,可控制感染發(fā)展、消除炎癥、腫脹、解除肌肉痙攣,而達成鎮(zhèn)痛止疼作用。對膝、踝關(guān)節(jié),扭傷、挫傷等造成軟組織損傷及周圍神經(jīng)損傷有良好診療作用。對風(fēng)濕、類風(fēng)濕患者膝關(guān)節(jié)炎有消炎消腫、鎮(zhèn)痛止疼作用,可降低關(guān)節(jié)活動受限范圍,提升骨關(guān)節(jié)病患者生活質(zhì)量。對這類患
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 2025年度珠寶企業(yè)社會責(zé)任與環(huán)保合作合同
- 二零二五年度汽車贈與及二手車置換增值服務(wù)合同
- 二零二五年度放棄祖屋繼承權(quán)的明確合同
- 2025年度石材幕墻安裝與維護管理合同協(xié)議
- 二零二五年度水資源保護融資合同
- 二零二五年度土地租賃合同糾紛處理指南
- 2025年度貨物損失賠償協(xié)議書:跨境電商供應(yīng)鏈風(fēng)險分擔(dān)合同
- 二零二五年度師徒互助職業(yè)技能提升協(xié)議
- 二零二五年度足浴店轉(zhuǎn)讓與市場推廣合作框架協(xié)議
- 2025年度涂料行業(yè)綠色生產(chǎn)推廣合同
- 浙江紹興市勘察測繪院下屬國有企業(yè)紹興市勘察測繪有限公司招聘筆試題庫2024
- 第1課《鄧稼先》課件語文七年級下冊2
- 2024年個人述職報告范文5
- 2024過敏性休克搶救指南(2024)課件干貨分享
- 植物抗逆性育種和遺傳改良
- 2024智能網(wǎng)聯(lián)汽車自動駕駛功能仿真試驗方法及要求
- 人教PEP四年級英語下冊Unit5 My clothes 教學(xué)設(shè)計(含教學(xué)反思)
- 2024年江蘇農(nóng)林職業(yè)技術(shù)學(xué)院單招職業(yè)適應(yīng)性測試題庫含答案
- 現(xiàn)代通信技術(shù)導(dǎo)論智慧樹知到期末考試答案章節(jié)答案2024年北京科技大學(xué)
- 工業(yè)分析全套課件完整版全冊電子教案
- 兒科病史采體格檢查
評論
0/150
提交評論