HM AS-H1.5安瓿滅菌器SOP 1.01_第1頁
HM AS-H1.5安瓿滅菌器SOP 1.01_第2頁
HM AS-H1.5安瓿滅菌器SOP 1.01_第3頁
HM AS-H1.5安瓿滅菌器SOP 1.01_第4頁
HM AS-H1.5安瓿滅菌器SOP 1.01_第5頁
已閱讀5頁,還剩2頁未讀, 繼續(xù)免費閱讀

下載本文檔

版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進(jìn)行舉報或認(rèn)領(lǐng)

文檔簡介

1、Document Type: Standard Operating Procedure(SOP)Document Name:HM AS-H1.5AMPOULE AUTOCLAVE 1.5M3 SOP Rev 1.01Document No.:HM2008Revision No.:1.01HM PHARMACHINE 安瓿滅菌器HM AS-H1.5AMPOULE AUTOCLAVE 1.5M3標(biāo)準(zhǔn)操作規(guī)程STANDARD OPERATING PROCEDURE (SOP)(供客戶參考,詳見使用說明書)This document is only reference for users,Refer

2、to instruction manual for details描述:Description 本文件由用戶和臺州惠美商貿(mào)有限公司雙方共同確認(rèn)。This document is the approval of the protocol from both parties HM PHARMACHINE CHINA LTD. and user.本文件僅適用于下面所述項目。This documentation only applies to the project below described.沒有臺州惠美商貿(mào)有限公司同意,本文件不得被復(fù)制或提供給第三方。The documentation mus

3、t not be reproduced or given to third parties without being written allowed by HM。責(zé)任: Responsible臺州惠美商貿(mào)有限公司負(fù)責(zé)編輯設(shè)備確認(rèn)草案并向客戶提交進(jìn)行確認(rèn);用戶在執(zhí)行前審核和批準(zhǔn)本方案。The documentation must not be reproduced or given to third parties without being written allowed by HM。設(shè)備名稱:Equipment:設(shè)備型號:Equipment Type:設(shè)備編號:Equipment No:協(xié)

4、議批準(zhǔn)Protocol Approval:標(biāo)題Title名字Name 簽名Signature 日期Date Prepared byHM工程師HM Project Engineer復(fù)核人wed byHM 主管HM Director批準(zhǔn)人Approved by客戶質(zhì)量主管Customer Director of Quality and Regulatory審核人Approved by客戶技術(shù)經(jīng)理Customer Technical Manager文件協(xié)調(diào)員Document Coordinator客戶確認(rèn)Customer Validation協(xié)議完成(簽名后,協(xié)議就完全完成了)Protocol Co

5、mpletion (To be signed only after protocol has been completed):標(biāo)題Title名字Name簽名Signature日期Date執(zhí)行人員Executed By:客戶工程測試員Customer testing engineers審核 人員Approved by客戶質(zhì)量主管Customer Director of Quality and Regulatory審核 人員Approved by客戶技術(shù)經(jīng)理Customer Technical Manager文件協(xié)調(diào)員Document Coordinator客戶確認(rèn)Customer Validat

6、ion A© 2012 HM PHARMACHINE SWISS GMBH.All rights reserved. No part of this work covered by copyright may be reproduced or copied in any form or by any means (graphic, electronic or mechanical, including photocopying, record taping, or information retrieval systems) without the written permissio

7、n of HM PHARMACHINE SWISS GMBH.目錄Table of Contents1、目的PURPOSE. 52、適用范圍RANGE .53、責(zé)任者RESPONSIBLE.54.、程序Procedure: 54.1設(shè)備描述 Equipment descripation54.2使用前準(zhǔn)備:Preparation before for use.54.3開機(jī)前準(zhǔn)備:Prepartion before opening machine64.4開機(jī)操作程序:Open machine operation procedure64.5 關(guān)機(jī)程序 Close machine procedure6

8、5、注意事項與日常保養(yǎng).7一、目的:建立HM AS-H1.5安瓿滅菌器標(biāo)準(zhǔn)操作規(guī)程,使操作達(dá)到規(guī)范化、標(biāo)準(zhǔn)化,保證產(chǎn)品質(zhì)量。I.Purpose:Establish HM AS-H1.5 Ampoule autoclave 1.5m3 standard operation procedure,make operation reached normalization,standardization,to ensure product quality.二、適用范圍:適用于HM AS-H1.5安瓿滅菌器標(biāo)準(zhǔn)操作。 Range:suitable for HM AS-H1.5 Ampoule autocl

9、ave 1.5m3 operators.三、責(zé)任者:操作工、車間管理人員。III.Responsible person: Operators ,workshop administrator四、程序:.Procedure:4.1設(shè)備描述 Equipment descripationHM AS-H1.5機(jī)動門安瓿滅菌器主要用于安瓿、口服液、小輸液瓶等藥品制劑的滅菌、檢漏和清洗處理。它利用壓力蒸汽作為滅菌介質(zhì), 可實現(xiàn)110127溫度區(qū)間的均勻滅菌,采用預(yù)真空升溫方式,保證滅菌室內(nèi)冷空氣排除徹底,升溫迅速均勻, 并有效消除了因冷空氣存在而造成的溫度死角。工作過程中通過真空加色水檢漏,保證廢品檢出率1

10、00%。 HM AS-H1.5 series ampoule sterilizer is mainly used in the sterilization, leakage inspection and cleaning of ampoule, oral liquid or small transfusion bottle medicine. Steam of a certain pressure is used as sterilizing medium, even sterilization between 105127 can be achieved. Replacing gas exh

11、austing and heating is used, the cold air in chamber is discharged thoroughly, and the heating is even and fast, then temperature dead corner caused by cold air can be avoided effectively. Vacuum and color water are used in the leakage inspection, 100% nonconforming products can be identified. 4.1.1

12、主要技術(shù)參數(shù) Main technical parameter額定工作壓力Technical parameter0.21 Mpa 最高真空度Highest vacuum degree:-0.089 MPa工作溫度范圍Range of working temperature:105127(建議滅菌溫度advise sterilize temperature)蒸汽源供給 Steam source pressure:0.30.5MPa真空泵水源Water source of the vacuum pump:0.20.5MPa壓縮空氣供給Compressed air pressure:0.40.8MP

13、a控制電源Controlling power:AC220V50Hz0.5KW動力電源Driving power:AC380V 50Hz滅菌時間范圍sterilizationTime range09999秒09999 seconds清洗時間范圍clean time range09999秒09999 seconds安全閥開啟壓力safety valve open pressure0.23 Mpa安全閥關(guān)閉壓力safety valve close pressure0.21 Mpa 4.2使用前準(zhǔn)備:Preparation before for use4.2.1檢查現(xiàn)場是否達(dá)到清場要求 Check s

14、ite if reach site-clearing requirements.4.2.2將“清場合格證”副本附入輔助生產(chǎn)記錄。Make"site-clearing certificate " copy attached auxiliary production record.4.2.3操作者要熟悉本設(shè)備的每個組成部分,聯(lián)線操作時更應(yīng)熟悉全部單機(jī)和周圍環(huán)境。 Operator should familiar with this equipment every part,and all the single machines and around environment wh

15、en connect wire operation. 4.2.4檢查外界電源、電壓與本機(jī)連接應(yīng)正確、檢查各電機(jī)運行應(yīng)正常;Inspect outside electrical source,voltage and this machine connecting if correct,inspect every motor if running normally.4.2.5檢查機(jī)器上的緊固件應(yīng)無松動、脫落。Inspect fastener of machine should no loose,drop.4.3開機(jī)前準(zhǔn)備:Prepartion before opening machine4.3.1

16、 啟動壓縮機(jī),使壓力上升到需要值,然后打開壓縮氣閥。Ø將蒸汽管道內(nèi)的冷凝水排放干凈,然后打開與滅菌器連接的蒸汽源開關(guān),并檢查其壓力是否達(dá)到0.3 0.5Mpa。Start compressed machine, make pressure increased to required value, then open compressed air valve. Make steam pipe inside condensated water drained, then open steam source switch which connected with autoclave,and

17、 inspect its pressure if reach 0.3 0.5Mpa.4.3.2打開用戶色水源、備用水源、去離子水源閥門開關(guān),為程序進(jìn)行做準(zhǔn)備。Open users color water source, ready water source, go ion water source valve switch, prepare for procedure processing.4.3.3打開真空泵水源閥門,并檢查水源壓力是否達(dá)到0.150.30MPa規(guī)定壓力值。Open vaccum pump water source valve, and check water source

18、pressure if reach 0.150.30MPa required value.4.3.5接通動力電源和控制電源。Get through power electrical source and control electrical source. 4.4開機(jī)操作程序:Open machine operation procedure4.4.1打開密封門,將裝載滅菌物品的內(nèi)車推入滅菌室內(nèi)。Open sealed door, make inside cart which loaded sterilization goods pushed into sterilizing room.4.4.

19、2關(guān)閉密封門,選擇滅菌程序,設(shè)置滅菌參數(shù),當(dāng)確認(rèn)滅菌參數(shù)毋需修改后,啟動滅菌程序。Close sealed door,choose sterilize procedure,set sterilize parameter,when confirm sterilize parameter no need revise,then start sterilize procedure.4.4.3滅菌過程中,操作人員應(yīng)密切觀察設(shè)備的運行狀況,如有異常,及時處理。In sterilize process,operators should observe equipment running status,if

20、 unnormal,solve in time.4.4.4.滅菌結(jié)束后,待室內(nèi)壓力回零后,方可打開后門取出滅菌物品。After finish sterilization,after room inside pressure return 0,then can open back door to take out sterilize goods.4.4.5滅菌物品從車內(nèi)取出后,應(yīng)仔細(xì)檢點放置,并做好記錄。After take out sterilization goods form cart,should check carefully lay up,and record well.4.5 關(guān)機(jī)程序 Close machine procedure4.5.1打開前門,切斷設(shè)備

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

評論

0/150

提交評論